Breter Catalog 2006
Breter Catalog 2006
it
R SERIES
Cam switches LEGENDA
1
General features
The features and the use of the best • Use for breaking, changing-over, making and starting of circuits with inductive
standard of materials assure the quality, or resistive electric loads; rated loads from 16A up to 315A
reliability and safety of breter cam-swit- • High resistance to mechanical stress and to tracking, dimensional stability.
ches, as confirmed by the approvals • Double break silver alloy contacts
granted by the most important interna-
• Screw terminals for cables with/without cable terminal, of easy identification
tional test houses.
• Special electrical schemes available on request
• Wide range of attachments to obtain many versions
• Quality and reliability for the highest safety of operation on control circuits
• Convenience and pratical use
• Compliance with international specifications
• Ip degree of protection according to IEC 529, CEI 70-1
• CEI/EN 60445 is the standard applies to the identification and marking of
terminals of electrical equipment
2
Typical applications of cam switches
On-off switch
Two-position switches used to connect and disconnet any electtical supply. They are used in a variety of power
switchig applications like manual control of direct on-line motors and isolation of motor branch circuits.
Changeover switch
Three-position switches used in power applications to change between alternate electrical supplies. Changeover
switches are typically used to switch the power supply from the primary source to a stand-by generator or emergency
supply in the event of a power outage.
Step switch
Multi-position switches used to connect a variety of loads to an electrical supply in a predeterminated logical sequence.
A typical application would be temperature control of a heating oven or furnace.
Reversing switch
Three-position (Forward, Off,Reverse) switches used to manually control the direction of rotation of a motor. Operating
the switch changes the wiring configutation to the motor to operate in the forward or reverse direction.
Dahlander switch
Three-position (1st speed, off, 2nd speed) switches used to select 2 different speeds of rotation of a motor. Operating
the switch changes the wiring configutation and the number of poles of the motor (i.e. 4/2, 8/4, etc.).
The second speed is always two times the first one.
Ammeter switch
Multi-position switches used to connect one or more phases of the electrical supply to an ammeter, so that the current
in each phase can be displayed on the ammeter.
Voltmeter switch
Multi-position switches used to connect two lines of the electrical supply system to a voltmeter, so that the voltage
between lines (phase-to-phase or phase-to-neutral) can be displayed on the voltmeter.
3
4
Utilization categories
To choose the most suitable and eco- • AC-1 Non-inductive or slightly inductive loads, resistance furnaces
nomic cam-switch in relation to the • AC-3 Squirrel-cage motors: starting switching off motors during running
specific application it is necessary to • AC-4 Squirrel-cage motors: starting, plugging, inching
compare the operating parameters of • AC-12 Control of resistive loads and solid state loads with isolation by optocouplers
the unit to be controlled (voltage, • AC-13 Control of solid state loads with transformer isolation
current and power) with the cam- • AC-15 Control of a.c. electromagnetic loads
switch performance. • AC-20 Connecting and disconnecting under no-load condition
To make this comparison consult the • AC-21 Switching of resistive loads, including moderate overloads
IEC/EN 60947-1-3, 60947-5-1, • AC-22 Switching of mixed resistive and inductive loads, including moderate overloads
60204-1, specifications for the utili- • AC-23 Switching of motor loads or other highly inductive loads
zation categories.
• DC-1 Non-inductive or slightly inductive loads, resistance furnaces
• DC-3 Shunt-motors, starting, plugging, inching, dynamic breaking of motors
• DC-5 Series-motors, starting, plugging, inching, dynamic breaking of motors
• DC-12 Control of resistive loads and solid state loads with isolation by optocouplers
• DC-13 Control of d.c. electromagnets
• DC-20 Connecting and disconnecting under no-load conditions
• DC-21 Switching of resistive loads, including moderate overloads
• DC-22 Switching of mixed resistive and inductive loads, including moderate
overloads (e.g. shunt motors)
• DC-23 Switching of highly inductive loads (e.g. series motors)
Average full load currents of squirrel cage motors
(alternate current 4 poles 1500 rpm)
Ampére
kW
230V 400V 500V 690V
0,06 0,41 0,24 0,19 0,14
0,09 0,62 0,36 0,29 0,21
0,12 0,83 0,48 0,38 0,28
0,18 1,16 0,67 0,54 0,39
0,25 1,43 0,83 0,66 0,48
0,37 1,90 1,10 0,88 0,64
0,55 2,67 1,55 1,24 0,90
0,75 3,45 2,00 1,60 1,16
1,10 4,75 2,75 2,20 1,60
1,50 6,05 3,50 2,80 2,05
2,20 8,45 4,90 3,90 2,85
3,00 11,70 6,80 5,40 3,90
4,00 15,00 8,70 7,00 5,00
5,50 19,50 11,30 9,10 6,50
7,50 25,50 14,80 11,90 8,60
11,00 37,00 21,50 17,00 12,50
15,00 50,00 29,00 23,00 17,00
18,50 60,50 35,00 28,00 20,50
22,00 72,50 42,00 33,50 24,50
30,00 97,50 56,50 45,00 32,50
37,00 117,00 68,00 54,50 39,50
45,00 141,00 82,00 64,00 47,00
55,00 173,00 100,50 80,00 57,00
75,00 229,00 133,00 106,00 77,00
90,00 272,00 158,00 126,00 91,00
110,00 333,00 193,00 153,00 110,00
5
Series R
Front mounting - On-off switches
Standard handle
40 90°
0 54 13.01.11 13.02.11 13.03.11 13.04.11
25
1 13.01.11C 13.02.11C 13.03.11C 13.04.11C
72
25 1.01.11 1.02.11 1.03.11 1.04.11
Padlockable handle
6
Series R
Base mounting - on-off switches
Standard handle
Padlockable handle
7
Series R
On-off switches
8
Series R
Changeover switches
9
Series R
Changeover switches
66
handle RC323253B RC323254B
32
key RC323253DC RC323254DC
0 45° handle RC403253B RC403254B
1 2
40 key RC403253DC RC403254DC
10
Series R
Motor switches
Standard handle
Y SWITCHES
Rated Rated IP Dim. Y- reversing switch
current power Pe protect. mmxmm 0
Y 0 0 Y 0
Y Y Y
Ie AC-21A (A) AC-23A (kW) 4 banks 4 banks 4 banks 5 banks
45°-90° 60° 30°-60° 45°-90°
54 13.10.11 13.70.11 13.54.11 13.12.11
25 7,5
40 13.10.11C 13.70.11C 13.54.11C 13.12.11C
72
25 11 1.10.11 1.70.11 1.54.11 1.12.11
32 18,5 RE327323A RE327553A
64
40 22 RE407323A RE407553A
50 22 RE507323A RE507553A
88
75 30 66 RE807323A RE807553A
Y
0
120 45 130 RE1257503A
60°
11
Series R
Step switches
1
2
1 bank 2 banks 3 banks 4 banks
54 13.41.11 13.42.11 13.43.11 13.44.11
25 40
45° 72 13.41.11C 13.42.11C 13.43.11C 13.44.11C
1
2
2 banks
3 54 13.38.11
25 40
45° 72 13.38.11C
1
2
2 banks 4 banks 6 banks
3 54 13.46.11 13.47.11 13.48.11
25 40 4
45° 72 13.46.11C 13.47.11C 13.48.11C
1
2
3 banks 6 banks 9 banks
3 54 13.49.11 13.50.11 13.51.11
25 40 6 5 4
45° 72 13.49.11C 13.50.11C 13.51.11C
12 5 banks
3
10 4 54 13.52.11
25 40 9
876
5
30° 72 13.52.11C
12 1 2 6 banks
11 3
10 4 54 13.53.11
25 40 9
876
5
30° 72 13.53.11C
12
Series R
Voltmeter / ammeter switches
Front mounting
VOLTMETER SWITCHES
3 phase for 3 for phase to phase for 3 phase for 1 phase
phase to phase of two 3-phase lines and 3 phase to phase and 3 phase to phase
Rated current IP Dimensions 0 RN 0 RS T1R1
0 RS RS
0 RN RN
0 RS
Front mounting
AMMETER SWITCHES
For direct measure 1 pole for 1 1 pole for 3 1 pole for 4 2 poles for 3
without break current transformer current transformer current transformers current transformers
Rated current IP Dimensions 0 0 0 1 0
16 48 14.22.11
54 13.14.11 13.20.11 13.22.11 13.23.11 13.25.11
25 40
13.14.11C 13.20.11C 13.22.11C 13.23.11C 13.25.11C
72
25 1.14.11 1.22.11 1.25.11
45x54
45
64
80
13
Series R
Accessories - handles and actuators
Series Code
Standard handle
Black - lenght 40mm 13 G1392N
Red - lenght 40mm 13 G1392R
Black - lenght 50mm 13, 1 G1527N
14
Series R
Accessories
Series Code
Gaskets to obtain IP54 degree of protection for basic version IP40 13 G1683
13, 1 G1590
Central mounting Ø 22mm key operated removable R32, R40 G3805 + LFC2-DD-001
in “0” position
Installation tool for tightening the central fixture nut (Ø 22mm) R32, R40 P3906
Adapter plate for 4 fixing holes 68x68mm or 86x86mm R50, R80 REG3516
Adapter plate for 4 fixing holes 68x68mm or 104x104mm R125..R630 REG3517
15
Series R
Accessories - Protections
Series Code
Terminal covers front mounting 13, 1 P21853
(3/4 poles) R32 RE32C4
R40 RE40C4
R50 RE50C4
R80 RE80C4
R125 RE125C4
16
Series R
Accessories
Series Code
Front installation shaft R32, R40
Lenght 34 mm Termoplastc (standard) L2-G3380
Lenght 34 mm Metal L7-G3688
Lenght 34 mm Termoplastic G3189
(to turn position 90° anti-clockwise)
Lenght 34 mm Termoplastic G3186
(to turn position 90° clockwise)
Base installation shaft R32, R40
Lenght 44 mm Termoplastic (standard) LA2-G2830
Lenght 44 mm Metal L7-G3687
Lenght 52 mm Termoplastic LA2-G3194
Lenght 52 mm Metal L7-G3707
Lenght 57 mm Termoplastic LA2-G3195
Modular shaft extension R32, R40 LA2-G2853
2 overlapping modules 24 mm
(Max 4 modules - total lenght 96 mm)
IP54
Termoplastic enclosure - side operated lever 122x97 h 79mm 13 6 G2401
1 6
IP55
Metal enclosure - side operated lever 113x95 h 85mm 13 5 G2403
1 5
IP55
Termoplastic enclosure - front actuator 130x95 h 91mm 13 4 G2533
1 4
IP54
17
Series R
Accessories - Legend plates
P22850 NEUTRAL
P22921 P24447 P24720 P24143 NEUTRAL IN ALUMINIUM
54x54mm
0 OFF 1 0 2 0
MAN AUT
1 ON
0 TR
P24892 P24907 NEUTRAL
Series 13,1
72x72mm
0 OFF 0 0
1 2 MAN AUT
1 ON
18
Series R
Mounting examples
Series R 32/40
Base mounting type
Series R 50/80/125…630
Base mounting type
Series R
Front mounting type
19
Series R
Technical informations
20
Series R
Technical informations
# # #
25 32 40 50 75 120 200 250 315
5 5 5# 5# 5# 6 8 12 15
25 35 40# 50# 63# 100 160 250 315
0,5 0,8 0,8 1# 1,5# 2,4 4 5 6,5
25 32 40 50 75 120 200
16 25 25 40 63 100 200
60 60 60 60 60 48 42
21
Series R
Technical informations
UL / CSA Series 14 13 1 ➀
General use 1 phase/2 poles, 3 phase/3 poles
Rated current 600 V A 20 16
Heavy Pilot Duty (AC) Code designation A 600
Standard Duty (DC) Code designation P 600
Rated operational power
Across the line AC motor starting
DOL-Rating 120 V HP 1,5
1 phase 2 poles 240 V HP 3 3
480 V HP 5 6 ➁
600 V HP 5 7,5
3 phases 3 poles 120 V HP 2
240 V HP 5 6
480 V HP 10 12 ➁
600 V HP 10 15
ENVIROMENTAL DATA
Ambient temperature: Operation: -25°C a +60°C
Storage: -40°C a +80°C
MECHANICAL DATA
Protection class according to IEC/EN 60529
Actuators IP40 IP40..IP55 IP40..IP55
Switch bodies IP00 IP00 IP00
Mechanical life Milion of operations 1 2 1,5
Terminal sizes according to IEC/EN 60947-1 gauge form
Min./max. wire cross section A2 A3 A3
Fine strands mm2 0,75/2,5 1/2,5 1/2,5
Solid or stranded mm2 0,75/2,5 1/4 1/4
Max. wire gauges according to UL/CSA (solid/stranded) AWG 14/14 10/12 10/12
Terminals Type screw screw screw
Thread M3 M3,5 M4
Screw driver size 2/1 3/2 3/2 3/2
recommended torque (Nm) 0,6 1,2 1,2 1,2
APPROVALS
CE-confirmal • • •
CSA (Canada) • •
IMQ (Italy) •
UL-Listed (USA)
UR (USA) •
• Approved as a result of test passed
➀ Only CSA approval ➁ For CSA 220V e 440V ➂ Only UL approval
22
Series R
Technical informations
2 2 3 5 ➂ 7,5 10
5 5 7,5 10 ➁ 15 20
7,5 10 15 20 ➁ 30 40
10 15 20 25 ✓ 35 50
5 5 7,5 10 ➂ 15 25
7,5 10 15 20 ➁ 30 50
20 25 30 40 ➁ 60 75
20 25 40 50 ✓ 75 100
A5 A5 A5 A5 B7
2,5/6 2,5/6 2,5/6 2,5/16 1,5/35
2,5/10 2,5/10 2,5/10 2,5/25 1,5/50
8/10 8/10 8/10 4/6 1/2
screw screw screw screw screw embedded hexagon embedded hexagon embedded hexagon
M4 M4 M5 2xM4 2xM6 M10 M12 M14
3/2 3/2 3/2 3/2 4/- hexagon 8 mm hexagon 10 mm hexagon 12 mm
1,8 1,8 2 1,2 2 10 14 19
• • • • • • • •
• • • • • • • •
• • •
• •
• • • • • •
23
Series R
Dimensions - Fixing holes
Front mounting
H
A C D
B L E G
14 - 32 - 54 - - - - 48 23,5 Ø 35
13 37 50 62 75 87 100 112 125 54 or 72 28 or 32 Ø 47 72 38 1,5
1 35 48 60 73 85 98 110 123 72 32 Ø59
R32
41 58,5 76 93,5 111 128,5 146 163,5 64 28 Ø 61 67 34
R40
R50 51 69 87 105 123 141 159 177
88 45 Ø 80 90 49
R80 60 87 114 141 168 195 222 249
4
R125 118x102
83 113 143 173 203 233 263 293
R250 118x191
130 55 135 - 120 70
R400 113 173 233 293 353 413 473 533
118x180
R630 143 233 323 413 503 593 683 773
36x36 o 48x48 42
B 14
A A
C
24
Ø 9,5
C
Ø 3,2
BODIES/ACTUATORS 20
Series 13, 1, R32, R40, R50, R80
BODIES/ACTUATORS 100
BODIES/ACTUATORS
Series 14 fixing
Series A B C Alternative fixing
for series 13, 1, R32, R40
13 32
1
9,5 3,2
R32 33 5,3
R40
R50
12 46 5,3
R80
BODIES/ACTUATORS
Series R125..R630
Central mounting Ø 22mm
1…6mm
+0,2
3,2 0
+0,4
24,1 0 Ø 30 C
+0,4
22,3 0
A L B
Series L N° of banks A B C
1 2 3 4 5 6 7 8
13 69 82 94 107 119 132 144 157 36 26 Ø 47
R32
86 103,5 121 138,5 156 173,5 191 208,5 41 28 Ø 61
R40
24
Series R
Dimensions - Fixing holes
Base mounting
S
1…6mm
A C A C D
F
L
T B E G
Y L
X
B
I
L L
M
Q O
M
ACTUATORS
ACTUATORS
P
BODIES
ACTUATORS BODIES
Series A B C D E F G H I L M N O P Q R
(mm x mm)
13 54 o 72 28 51x51 32 36 36
72 38 58 9,5
1 72 32 33
3,2 M4
R32 78x55 - - 70 15
64 28 67 34 - - 36 o 48 17
R40
R50
88 45 102x102 92 49 12 85 85
R80
-
R125
68 5,3 M5
R250
130 55 57x148 135 - 120 70 20 37 132
R400
R630
25
Diagrams
09 3 Poles dahlander switch 14 Ammeter sw. for direct 19 Voltmeter switch 1 phase and 3 phase to phase
SERIES R (13, 1) Y-T8 measure without break
7 4 5 19 11 1 N
01 1 Pole on-off switch 3 U-T1
15 4
W-T3
L1
L2
A V L1
L2
13 L3 16 0 RS L3
5 8 RN
1
0
2 Z-T9 V-T2 X-T7 16 14 3 ST
10 8 2 12
L1 TR
45°
3-4 X 4
1 L2 11 12
45° 15 16 11 12
1-2 L3 11-12 X X
0 13 14 3
Elements
3 4 10
Contact
0 1 15-16 X 16 12 2 9-10 X
1 4
13-14 X 7-8 X X
Pos. 90° 2 8
11-12 X L4 5 5-6 X
3
9-10 X L5 3-4
3 4 1
02 2 Poles on-off switch 1 3 7-8 X L6 1-2 X X
2 7 8
5-6 X
Elements
2
Contact
ST
TR
RS
RN
3 11 19 0
3-4 X 5
1 Positions
1 2
1-2 X 19-20 X X
5
3 4 17-18
Contact
Element
2 4 1 0 2
3-4 X 15-16 X X 20 1 Pole ammeter switch for 1 current transformer
1 Pos. 4
1-2 X 13-14 X X
0 11-12 X X
Elements
3 4 3
Contact
0 1 9-10 X X 0
1 10 Star-Delta switch L1
Pos. 90° 1 2 7-8 X X 1
2
5-6 X X 90° 2
U-T1 Y-T8 3-4 X X
15 7 L1 1 1 A 3
03 3 Poles on-off switch 1 3 7 1-2 X X 90° 3-4 X X
L2 1
0 1-2 X X
Elements
Z-T9 5 4 W-T3
Contact
L3 0 R S T
Elements
13 8 T R 3
Contact
0 1
Y V-T2 X-T7 16 14 3 Positions S
0
Pos.
1 2
2 4 8 45°
7-8 X 90° 15 16 15 3 Phase voltmeter switch
2 22 1 Pole ammeter switch for 3 current transformers
5-6 7 8 13 14
15-16 X X 0 RN 3 7
3-4 4
1
1-2
X
X
13-14
11-12
X X
X TN
SN V L1
L2
0
3 4 3 0 45° 12
L3
Contact
Element
0 1 9-10 X
1
1 2 7-8 X 9
Pos. 90° 2 7-8 X X X
5-6 X 7 8 2 8 12 2
5-6 X 7 8
3-4 X X 5 8
04 4 Poles on-off switch 1 3 5 7 1 3-4 X 6 9 A 1
1-2 X 1
1-2 X
3 4
Contact
Element
0 Y 3 4
Contact
Element
RN
SN
TN
0 0
Pos.
Positions
2 11-12 X X
3 1 2
2 4 6 8 9-10 X X
7-8 X 11 Pole changing reversing switch 16 3 Phase to phase voltmeter switch 2
7-8 X X
2 7 8 5-6 X X
5-6 X Y-T8
3-4 X 0 RS 3 7 3-4 X X
5 6 1
1
1-2 X
U-T1
10
W-T3
L1 ST V 1-2 X X
0
Elements
0 4 25 TR
Contact
3 4 L2 0 0 1 2 3
Contact
45°
Element
0 1 1
0 3 1
1 1
15 L3
Pos.
1 2 0 0 5 9 Positions 2 90°
90° 7-8 X
2 2
45° Z-T9 V-T2 X-T7 23 19 3 2
5-6 X X 7 8
05 1 pole changeover switch 3-4 X 6 23 1 Pole ammeter switch for 4 current transformers
25 1
27-28 1-2 X X
7 23
25-26 X X
Elements
3
Contact
RS
ST
TR
3-4 X 23-24 X X 0 0 L1
1 6 2 L2
1-2 X 21-22 X X Positions
0 19 L3
3 4 19-20 X X
Contact
Element
1 2
1 0 2 5 L4
17-18 X X 17 Voltmeter switch 3 Phase to phase of 2-3 phases lines
Pos.
2
45° 15-16 X X 15
4 4 12 2 6
13-14 X X 7 15
06 2 Poles changeover switch 3
11-12 X X V 15 A 7 15
9-10 X X T1R1
0 RS
7-8 9 10 S1T1 ST
7-8 X 2
2 5-6 X X R1S1
0
TR
5-6 X 7 8 45° 15 16 12
3-4 X X
3-4 X 6 1 5 14
1 1-2 X X 15-16 X X
1-2 X 4
Elements
3 4 13-14 X X
Contact
0
3 4 2 0 1 0 1 0 2 12 7
Contact
Element
1 2
1 0 2 11-12 X
2 Positions 3 10 6
Pos. 9-10 X
45° 7-8 X
2
12 Star-Delta reversing switch 5-6 X 7 4
07 3 Poles changeover switch 3-4 X X
1 2
U-T1 Y-T8 1-2 X X
4 8 L1 15-16 X X
11 12 4
S1T1
T1R1
R1S1
X 4 2 8 6 12 10
Elements
11-12 L2 4
Contact
RS
13-14
ST
TR
3 0 0 X X
9-10 X 10 Y
0
Y
Z-T9 7 10 W-T3 L3 2 11-12 X X
12 5 Positions 3
7-8 X 45° 9-10 X X
2 3 7 11 7 8 V-T2 X-T7 19 15 3
5-6 X 90° 7-8 X X
3-4 X 18 Voltmeter switch 3 phases and 3 phase to phase 2
1 6 19 5-6 X X
1-2 X 19-20 X X 3-4 X X
5 1
0
3 4 17-18 X X 11 9 1-2 X X
Contact
Element
1 2 N
1 0 2
15-16 X X 15 V 1
Elements
4 L1
Contact
2 1 2 3 4
Pos. 45° 13-14 X X 4 2
L2
11-12 X X Positions 3 90°
3 0 RN L3
9-10 X X 12 RS
08 3 Poles reversing switch 7-8 X X
ST SN
2 12 8 4
2 10 TR TN
5-6 X X 45°
11 12 7 8
11-12 X 3-4 X X X X 11 12
X 1 11-12 X X
3 1-2 X X 5 3
9-10 9-10 X 9
Elements
3 4
Contact
7-8 X Y 0 Y 7-8 X
2 11 7 3 7 8 2
5-6 X 5-6 X X 8
Positions
3-4 X 3-4 X X X
1 1
1-2 X 1-2 X X
0
3
Contact
Elements
Element
1 2
1 0 2 4
SN
TN
Contact
RN
RS
TR
ST
0
Pos.
2 2
45° Positions
26
Diagrams
25 2 Poles ammeter switch for 3 current transformers 41 1 Pole step switch 2 positions 50 2 Poles step sw. 6 positions 54 Star-Delta switch
3-4 X 1 U-T1 Y-T8
L1 A 1 2
15 7 L1
19 12 1-2 X 3
L2 1
L2
Elements
6 5 4
3 4 Z-T9 5 4 W-T3
Contact
2 45° L3
L3 1 2
23 24 13 8
Pos. 2 V-T2 X-T7 16 14 3
23-24 X 22 0 Y
11 20 13 14 5 2 6
19 20 21-22 X 15°
42 2 Poles step switch 2 positions 20
19-20 X 30° 15 16
5 18
7-8 17-18 X
X 13 14
2 7 8 15-16 X 16 15-16 X X
5-6 X 4 4
3-4 13-14 X 13-14 X X
13 14 X 6 14
1 11-12 X 11-12 X
1-2 X 3 3
1 9-10 X 11 12 9-10 X
Elements
11 12 3 4
Contact
2
1 2 7-8 X 10 7-8 X X
2 2
Pos.
2 5-6 X 5-6 X X 7 8
23-24 8
6 3-4 X 3-4 X X 5
21-22 X X 1 6 1
43 3 Poles step switch 2 positions 1-2 X 1-2 X
19-20 X X
Elements
Elements
5 4 3 4
Contact
5
Contact
17-18 X X 1 2 3 4 5 6 0 Y
11 12
15-16 X X 11-12 X Positions
2
4 3 10 Pos.
13-14 X X 9-10 X
11-12 X X 2 7-8 X
3 2 7 8 51 3 Poles step sw. 6 positions 55 Star-Delta reversing switch
9-10 X X 5-6 X
7-8 3-4 X 6
2 1 1 U-T1 Y-T8
5-6 X X 1-2 X 2
L1
1 3 35 36 15 7
ElementS
3-4 3 4 L2
Contact
2
1 1 2 6 5 4
45°
1-2 X X 34 Z-T9 5 4 W-T3 L3
Pos.
2 13 8
0 45° 32
Elements
Contact
A 3 4 11-12 X
Contact
2
Avv. ausiliario
1 2 3 2
45° 9-10 X 11 12 5-6 X X 7 8
Pos.
2
45° 7-8 X 3-4 X X X X 5
2 10 1
7-8 X X 5-6 X 1-2 X X
2 7 8 8
45 4 Poles changeover switch
Elements
5-6 X X 3-4 X 3 4
Contact
1 Y 0 Y
3-4 X 5 6 1-2 X 6
1 15 16 Positions
1-2
Elements
15-16 X 4
Contact
4 14 1 2 3 4 5 6
Elements
4 13-14 X
Contact
0 M A 2
11-12 X 11 12 Positions 57 1 Pole step sw. 3 positions + 0
Pos. 3
9-10 X
10 52 1 Pole step sw. 10 positions 0
1
7-8 X
2 2
30 Changeover sw. for remote control reverser 5-6 X 7 8 12 19 20 3
3-4 X 3 45°
Self-input 5 6 1 6 10 4
18
0
1-2 X 9
876
5
M M 0 30° 7-8 X
16 2
Elements
Impulse ahead 3 3 4
Contact
1 2 8
A A 1 0 2 5-6
45° 2 19-20 X 14 3-4 X
Impulse behind 1 Pos. 45° 5 1
17-18 X 12 1-2 X
15-16 X
Elements
4 4
Contact
7-8 46 1 Pole step sw. 4 positions 10 0 1 2 3
2 13-14 X
5-6 X X X X 11-12 1 2
X 8 Pos.
3-4 X 3
1 7-8 X 9-10 X 6
1-2 X 2 7 8 7-8
5-6 X X 58 1 Pole step sw. 4 positions + 0
2
Elements
4
Contact
A M 0 M A 3-4 X 6 5-6 X
1 3-4 0
1-2 X X 2 1
Positions 1
1 1-2 X 2
Elements
4
Contact
2
1 2 3 4 3
Elements
3 4 45°
Contact
4
Contact
9 1 0 1 2 3 4
0 11-12 X 12 22
M M 3 Pos.
2
A A U2 Z2 9-10 X
10 20
45° 7-8 X
Auxiliary winding
2 18
5-6 X 7 8 59 1 Pole step sw. 5 positions + 0
11 12 3-4 X 16
11-12 X X X X 1 6
3 9 10 1-2 X 0 1
9-10 X X X X 14
1 2
Elements
7-8 X 4
Contact
2
2 1 2 3 4 12 5
4
3
5-6 X 3 45°
Pos. 4 2
3-4 X 5 45° 10
1 11-12
1-2 X 8 3
9-10 X 9 10
48 3 Poles step sw. 4 positions
Elements
Contact
A M 0 M A 6 7-8 X
1 12 1 2
2 8
Positions 23 24 11 3 4 5-6 X
10 4
9 5 3-4 X 6
23-24 X 22 876
30° 2 1
6 1-2 X
37 Reversing sw. single phase motor + capacitor 21-22 X
20
Elements
4
Contact
19-20 X 23-24 X 0 1 2 3 4 5
V1 U1 V U 5 18 6
17-18 X 21-22 X 2
L1 Positions
7 2 10 4 15-16 X 15 16 19-20 X
L2 4 5
13-14 X 17-18 X
3 9 11-12
14 60 2 Poles step sw. 3 positions + 0
X 15-16 X
3 12 4
9-10 X 13-14 X 0
1
7-8 X 10 11-12 X 2
2 3 3
5-6 X 9-10 X 45°
7 8
3-4 X 7-8 X
11-12 X 1 2 12
3 1-2 X 6 5-6 11-12 X
9-10 X X 9 10 X 3
1 9-10 9 10
Elements
4 3-4 X X
Contact
7-8 X 2
1 2 3 4 1
2 7
3
1-2 X 7-8 X
5-6 X 4 2 2
Pos. 45° 5-6 X 8
Elements
3-4 X X
Contact
1 1 2 3 4 5 6 7 8 9 10 11 12 3-4
1-2 X X 6
1
0 49 1 Pole step sw. 6 positions Positons 1-2 X
Elements
3 4
Contact
1 2
1 0 2
Elements
3 4
Contact
1 0 1 2 3
Pos.
2 2
45° 3 2
Pos.
6 5 4
45°
38 1 Pole step switch 3 positions
11 12
11-12 X
3 10
9-10 X
7-8 7-8 X
2 2
5-6 X 5-6 X 8
3-4 X 6 3-4 X 6
1 1
1-2 X 1-2 X
1
Elements
3 4
Elements
Contact
1 2 3 2 4
Contact
3 1 2 3 4 5 6
Pos.
2 2
Positions
45°
27
Diagrams
61 3 Poles step sw. 3 positions + 0 65 2 Poles step sw. 6 positions + 0 3254 4 Poles changeover switch
0
1
SERIES R (R32..R630)
2 20 0 1 3 1 7 5 11 9 15 13
3
45°
6 2 1751 1 Pole on-off switch 1
5 3
4 45°
24
19-20 X 16 2 6 10 14
5 23-24 X 21 22
17-18 6
13 14 21-22 X
15-16 X 20 1-2 X 2
4 19-20 X 1
13-14 X 5 3-4 13 14
11 12 17-18 X 18
11-12 X 1 15
Elements
3 15-16 X 1 2
Contact
9-10 X 9 10 4 16 0 1 13-14 X
13-14 X 0 4
7-8 X 14 15-16 X
2 11-12 Pos. 90° 9 10
5-6 X 8 X 9-10 X
3 11 12 3
3-4 9-10 X 11-12 X 11
X 6
1
1-2 X 7-8 X 10 1752 2 Poles on-off switch 1 3 5-6 X
2 2
5-6 X 7-8 X 5 6
Elements
4 8
Contact
0 1 2 3 3-4 X
1 1-2 X 7
2 1-2 X 6 1
Pos. 3-4 X
Elements
4 0
Contact
Elements
0 1 2 3 4 5 6 1 2
Contact
2 4 1 2
1 0 2
62 2 Poles step sw. 4 positions + 0 2 1-2 X
Positions 1 Pos.
3
3-4 X 45°
0 1
Elements
1 1 2
Contact
2 66 3 Poles step sw. 6 positions + 0 0 1
3
0
3 4
3503 3 Poles changeover switch
4 45° 15 16 Pos. 90°
0 1
14 3 1 5 7 11 9
15-16 X 6 2 35 36 1753 3 Poles on-off switch 1 3 5
4 5 3
13-14 X 4 45° 34
12
11-12 X
3 10 32 2 8 10
9-10 X 35-36 X
9 30
7-8 X 33-34 X
2 7 8 2 4 6 9 10
5-6 X 31-32 X 28 9-10 X
8 5-6 X 3
3-4 X 6 29-30 X 11-12 X 11
1 26 2 5 6
1-2 X 27-28 X 7-8 5-6 X
7 23 24 1-2 X 2
25-26 X
Elements
4 7-8 X 5
Contact
0 1 2 3 4 1
23-24 X 22 3-4 X 1-2 X
2 6 1 1 7 8
21-22
Elements
Pos. X 1 2 3-4 X
20 Contact 0 1 0
19-20 X 0
Elements
5 3 4 1 2
Contact
17-18 X 18 Pos. 1 0 2 1 2
63 3 Poles step sw. 4 positions + 0 90°
15-16 X 3
4 16 Pos. 60°
0
23 24 13-14 X 1754 4 Poles on-off switch 1 3 5 7
1 14
2 22 11-12 X 3504 4 Poles changeover switch
3 11 12
4
3
45° 9-10 X
20 7-8 X 10 3 1 5 7 11 9 13 15
2
23-24 X 5-6 X
6 18 8 2 4 6 8
21-22 X 3-4 X 0
1 6 5-6 X 1 2
19-20 X 1-2 X 2 2 8 10 16
5 15 16 7-8 X 5 6
Elements
17-18 X 4
Contact
0 1 2 3 4 5 6 60°
14 1-2 X 7 8
15-16 X 2 1 13
4 Positions 3-4 X
13-14 X 13-14 X
12 1 4 15 16
Elements
1 2
Contact
11-12 X 0 1 15-16 X
3 10 67 1 Pole step sw. 7 positions + 0
0
9-10 X 3 4 9-10 X 9 10
Pos. 90° 3
7-8 X 11-12 X
2 7 8 7 0 1 11
5-6 X 5-6 X
6 2 2
3-4 X 6
1756 6 Poles on-off switch 1 3 5 7 9 11 7-8 X
1 5
4
3
45° 5
1-2 X 16 1-2 X
1 7 8
3-4
Elements
4 X
Contact
0 1 2 3 4 15-16 X
4 Elements 1 2
Contact
Pos.
2 13-14 1 0 2
12 2 4 6 8 10 12
11-12 X 3
3 Pos.
9-10 X 10
64 1 Pole step sw. 6 positions + 0 7-8 9 10
X 9-10 X
2
5-6 X 8 3 5261 1 Pole step switch 3 position + 0 3 1 5
0 1 11-12 X 11 12
6 2 3-4 X 6 5-6 X 2
5 3 1 2 1 3
4 45° 1-2 X 7-8 X 5 6 0
Elements
3 4 1-2 X
Contact
11 12 0 1 2 3 4 5 6 7 1 7 8 45°
11-12 X 3-4 X 4
3 2
9-10 X 10 Positions 1 5-6 X
Elements
1 2
Contact
7-8 0 1 2
X 0 7-8 5
2 8 3 4
5-6 X 70 Star-Delta switch Pos. 90° 1-2 X
3-4 X 1
1 6 U-T1 Y-T8 L1 3-4 X
1-2 X 3251 1 Pole changeover switch
Elements
15 7 L2 1
Contact
0 0 1 2 3
Elements
4 Y
L3
Contact
X 1 2 8
Contact
1 2
2 1 0 2
5-6 X
7 8 Pos.
3 5-6 X
3-4 X X 45° 2
1 7-8 X 5
1-2 X 5
1-2 X
3252 2 Poles changeover switch 3 1 7 5 1 7 8
Elements
3 4
Contact
Y 0 3-4 X
Elements
1
Contact
Pos. 0 1 2 3 4
Pos.
3
2 6
5-6 X
2 5 6
5281 1 Pole step switch 5 positions + 0
7-8 X 3 7 5 11 1
1-2 X 7 2
1 1 3
3-4 X 0 4
0
Elements
5
1 2
Contact
1 2
1 0 2 45°
3 12
Pos. 45° 9-10
3
11-12 X
3253 3 Poles changeover switch 11 12
5-6 X
2
7-8 X 5
3 1 7 5 11 9 1-2 X
1 7
3-4 X
Elements
1
Contact
0 1 2 3 4 5
2 6 10 3
Positions
9 10
9-10 X
3 11
11-12 X
5-6 X
2 5 6
7-8 X
1-2 X 7
1
3-4 X
0
Elements
1 2
Contact
1 2
1 0 2
Pos.
3
45°
28
Diagrams
7293 3 Poles Dahlander switch 08 3 Poles reversing switch 45 4 Poles changeover switch
1U
SERIES 14 U1 4 2 8 6 12 10 16 14
6
L1 01 1 Pole on-off switch 1 10
L1
2U 2W
14 1 L2 L2
L3 L3 1 5 9 13
0 5 16 8 6 4
1 2
1W 2V 1V 13 15 2 V1 W1 9 5 1 13 14
3-4 X 2
45° 1 13-14 X 16
1-2 4
13 14 0 9 10 15-16 X
Elements
13-14 1 1 2
Contact
X 0 1 9-10 X X 9 10
4 15 16 3 9-10 X
15-16 X 11-12 3
Pos. 45° 11-12 X 12
9-10 X 5-6 X
3 2 5 6 5-6 X
11-12 X 7-8 X 2
02 2 Poles on-off switch 1 3 7-8 X 5 6
5-6 X 1-2 X
2 1 1-2 X
7-8 X 5 6 3-4 X 1 8
3-4 X
1-2 X 0
Elements
1
Contact
1 2
1 8 1 0 2 0
Elements
Contact
1 2 1 2
3-4 X 1 0 2
Pos.
4
Elements
1 2 45° 4
Contact
1 0 2 2 4 Pos. 45°
1-2 X
1 16 3 Phase to phase voltmeter switch
Pos. 3-4 X
0
57 1 Pole step switch 3 positions + 0
Elements
1 1 2
Contact
0 1 L1 2 4 6
7303 3 Poles reversing switch 0 RS
5 1
3 4 L2
U1
Pos. 45°
0
TR
ST
45°
V L3
0
1
2
11 3
03 3 Poles on-off switch 1 3 5 6 4 8 45°
L1
3
0 L2 5-6 X
1 2 2 5 6 5-6 X
L3 7-8 X X 2
5 3 7-8 6
1-2 X 8
45° V1 W1 12 6 2 1 1-2 X
2 4 6 3-4 X X 1
3-4 X
Elements
9-10 1
Contact
RS
5-6
ST
TR
3 X 0 0
Elements
2
Contact
11-12 X X 11 12 2 5 6 0 1 2 3
7-8 4
5-6 X Positions 3 4
2 1-2 X Pos.
7-8 X 5 6 1
3-4 X
1-2 X 18 Voltmeter switch 3 phase and 3 phase to phase
0 67 1 Pole step switch 7 positions + 0
Elements
1 1 1 2
Contact
3-4 X 0 1
3 4 2 4 6 8 10 12 14
Elements
2 Pos. 13 5
Contact
1 0 2 45° N
Pos.
3 V L1
04 4 Poles on-off switch 1 3 5 7 L2
7 0 1
0 RN L3
7323 Star-Delta switch RS 6 2 1
ST SN 5 3
TR TN
4 14 10 12 4 45° 14
W2 U1 45°
6 14 L1 2 4 6 8 13-14 X
L2 13 14 4
5-6 X 15-16
W1 1 8 U2 L3 2 13-14 X X 10
Y 5 16 7-8 X 5 6 4 9-10 X
0 15-16 X X 3 12
V2 V1 13 15 2 1-2 X 7 8 11-12 X
45° 1 9-10 X 10
3-4 X 3 5-6 X
90° 11-12 X 12 2 6
0 7-8 X
Elements
14 1 1 2
Contact
13 0 1 5-6 X X
13-14 X X 2 1-2 X 8
4 15 16 3 4 7-8 X X 5 1
15-16 X X Pos. 45° 3-4 X
1-2 X
Elements
9-10 X 1 1 2
Contact
3 3-4 X 0 1 2 3 4 5 6 7
11-12 X 05 1 Pole changeover switch 4 2 4
Elements
SN
TN
Contact
RN
Positions
RS
TR
ST
5-6 X 0
2 4
7-8 X 5 6 Positions
1-2 X X
1 8 1
3-4 X 19 Voltmeter switch 1 phase and 3 phase to phase
1-2 X
Elements
1 2 1
Contact
0 Y 3-4 X
0 9 3 N
Elements
1 2
Pos.
V
Contact
1 2
1 0 2 L1
4 L2
7503 Star-Delta switch Pos. 45°
0 RS L3
W2 U1 RN
11-12
Contact
ST
TR
RS
X
RN
0 0
Elements
1 2
Contact
1 2
1 0 2
5-6 X 3 4
2 4 Positions
7-8 X 5 6 Pos. 45°
1-2 X X
1 8 22 1 Pole ammeter switch for 3 current transformers
3-4 X 07 3 Poles changeover switch
4 2 8 6 12 10
Elements
1 2
Contact
0 Y
L1
Pos. L2
L3
1 5 9
7553 Star-Delta switch
10 4 8 13
9 10
9-10 X
W2 U1 3 12 A
11-12 X 15 5 10
6 14 L1
5-6 X
L2 2
7-8 X 5 6
W1 1 8 U2 L3
5 16 1-2 X 8
1 13-14 5
0 V2 V1 13 15 2 3-4 X 4
Y 0 15-16 X X 8
Elements
1 2
Contact
1 2
1 0 2 9-10 X X
13 14 4 3
Pos. 11-12 X X
45°
15 16 5-6 X X 4
13-14 X X 2
4 7-8 X X
15-16 X X
1-2
9-10 X 1
3 3-4 X X
11-12 X 0
Elements
Contact
5-6 X 0 1 2 3
2 5 6
3 1
7-8 X Positions 2 90°
1-2 X X 8
1
3-4 X
Elements
1 2
Contact
Y 0
Pos.
29
Series R
Circuit diagrams
Contacts 1 2
Positions
29 - 30 29 30
8
31 - 32 31 32
from 32A to 315A
25 - 26
7 25 26
27 - 28
27 28
21 - 22
6 21 22
23 - 24
17 - 18 23 24
5
19 - 20 17 18
13 - 14
4 19 20
15 - 16
13 14
9 - 10
3
11 - 12 15 16
5-6 9 10
2
7-8 11 12
1-2
1 5 6
3-4
7 8
Banks
Contacts 1 2
Positions
3 4
Actuator
Notes
30
Series R
Ordering example for special switches
30° Order N. 0000/00
0 Date
60°
M Company Rossi & Bianchi
Contact Rossi
A
Ph. 02 555555 Fax 02 555555
45° X 10 pieces 1 week
Quantity Delivery date
90°
31 32
31 - 32 29 30
8
29 - 30 27 28
27 - 28
7 25 26
25 - 26
e
15 - 16
4 15 16
13 - 14
11 - 12 13 14
3
9 - 10
2
1
7-8
5-6
3-4
1-2
X X
X
X
X
0 M A
pl 11
3
12
10
4
m
Banks
Contacts 1 2
Positions
29 - 30 29 30
8
a
31 - 32 31 32
from 32A to 315A
25 - 26
7 25 26
27 - 28
27 28
Ex
21 - 22
6 21 22
23 - 24
17 - 18 23 24
5
19 - 20 17 18
13 - 14
4 19 20
15 - 16
13 14
9 - 10
3
11 - 12 15 16
5-6 9 10
2
7-8 11 12
1-2
1 5 6
3-4
7 8
Banks
Contacts 1 2
Positions
3 4
Notes
31
visit our web site:
www.breter.it
32
www.breter.it