0% found this document useful (0 votes)
486 views36 pages

Serie R e

Breter is an Italian manufacturer of industrial electrical switches with over 50 years of experience. It produces over 4,000 cam switch products that are used in applications like tools, industrial machines, automation, transportation and energy. The switches have silver alloy contacts and are rated for various current levels and utilization categories from controlling motors to solid state loads.

Uploaded by

v5bw57b7tz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
486 views36 pages

Serie R e

Breter is an Italian manufacturer of industrial electrical switches with over 50 years of experience. It produces over 4,000 cam switch products that are used in applications like tools, industrial machines, automation, transportation and energy. The switches have silver alloy contacts and are rated for various current levels and utilization categories from controlling motors to solid state loads.

Uploaded by

v5bw57b7tz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 36

www.breter.

it

Cam switches R series


from 16A to 315A
PROFILE
BRETER has been established in the fifties as a manufacturer of switches for industrial applications and achieved a key specialist role in the market of electro-
mechanical low-voltage industrial controls, especially due to its expertise on custom-designed products.
Product quality has been Breter distinctive and prestigious way to be succesful through the years.
Thanks to its development and constructive policies, today Breter's strength is a unit of 20.000 square meters, a specialists equipe, the leading position into the
major international markets besides Italy and a wordwide distribution network.
The Company works in Quality Warranty to ensure top quality levels, also confirmed by products conformity to UL/CSA and IEC/EN national and international
regulations and a number of approvals.

Breter faces the future with technological innovations applied to design systems, workshop, production and Quality Warranty structures.
High innovative production organizations are based on automatic assembly lines and automatic injection plastic materials presses as well as advanced gears for
quality control carried out on 100% of finished products.
Engineering systems exploit CAD technology to develop new solutions and improve products quality and functionality.
The Company Test Laboratory is equipped with gears and instruments suitable for electrical, mechanical and climatic high reliable tests both on prototypes and
finished products.
Breter complete range of standard and special versions for all power and control functions in electrical and electronic applications is typically used by OEM,
panel builders and installers in the following fields: tools and industrial machines, automation, transports, off-shore, lifting equipment, energy production and distri-
bution.
The whole Breter range covers more than 4 thousands products out of the catalog in addition to an even higher number of custom-designed products; cam swit-
ches and switch disconnectors from 10A up to 630A and a complete line of push buttons, selector switches and pilot lights Ø 16 - 22 - 30 mm with plenty of choi-
ces as far as functions and outward solutions.
Cam switches

R SERIES
Cam switches LEGENDA

For rated current from 16A to 315A Black legend plate


Wide range of electrical functions Grey legend plate
Special schemes Silver-grey legend plate
available on request Grey/black actuator
Type of fixing: front mounting, base Yellow/red actuator
mounting or central fixing Ø 22mm Key removable
Actuator with screw fixture or
central fixture Ø 22mm

1
General features

The features and the use of the best • Use for breaking, changing-over, making and starting of circuits with inductive
standard of materials assure the quality, or resistive electric loads; rated loads from 16A up to 315A
reliability and safety of breter cam-swit- • High resistance to mechanical stress and to tracking, dimensional stability.
ches, as confirmed by the approvals • Double break silver alloy contacts
granted by the most important interna-
• Screw terminals for cables with/without cable terminal, of easy identification
tional test houses.
• Special electrical schemes available on request
• Wide range of attachments to obtain many versions
• Quality and reliability for the highest safety of operation on control circuits
• Convenience and pratical use
• Compliance with international specifications
• Ip degree of protection according to IEC 529, CEI 70-1
• CEI/EN 60445 is the standard applies to the identification and marking of
terminals of electrical equipment
Typical applications of cam switches

On-off switch
Two-position switches used to connect and disconnet any electtical supply. They are used in a variety of power
switchig applications like manual control of direct on-line motors and isolation of motor branch circuits.

Changeover switch
Three-position switches used in power applications to change between alternate electrical supplies. Changeover
switches are typically used to switch the power supply from the primary source to a stand-by generator or emergency
supply in the event of a power outage.

Step switch
Multi-position switches used to connect a variety of loads to an electrical supply in a predeterminated logical sequence.
A typical application would be temperature control of a heating oven or furnace.

Reversing switch
Three-position (Forward, Off,Reverse) switches used to manually control the direction of rotation of a motor. Operating
the switch changes the wiring configutation to the motor to operate in the forward or reverse direction.

Dahlander switch
Three-position (1st speed, off, 2nd speed) switches used to select 2 different speeds of rotation of a motor. Operating
the switch changes the wiring configutation and the number of poles of the motor (i.e. 4/2, 8/4, etc.).
The second speed is always two times the first one.

Star Delta switch (Wye-Delta)


Three-position (Off, Wye, Delta) switches used to manually control the reduced voltage starting of a motor. Operating
the switch changes the wiring configutation to the motor from a star configuration to a delta cofiguration once the
person operating the conrtoller determines the motor is up to speed.

Ammeter switch
Multi-position switches used to connect one or more phases of the electrical supply to an ammeter, so that the current
in each phase can be displayed on the ammeter.

Voltmeter switch
Multi-position switches used to connect two lines of the electrical supply system to a voltmeter, so that the voltage
between lines (phase-to-phase or phase-to-neutral) can be displayed on the voltmeter.
Utilization categories

To choose the most suitable and eco- • AC-1 Non-inductive or slightly inductive loads, resistance furnaces
nomic cam-switch in relation to the • AC-3 Squirrel-cage motors: starting switching off motors during running
specific application it is necessary to • AC-4 Squirrel-cage motors: starting, plugging, inching
compare the operating parameters of • AC-12 Control of resistive loads and solid state loads with isolation by optocouplers
the unit to be controlled (voltage, • AC-13 Control of solid state loads with transformer isolation
current and power) with the cam- • AC-15 Control of a.c. electromagnetic loads
switch performance. • AC-20 Connecting and disconnecting under no-load condition
To make this comparison consult the • AC-21 Switching of resistive loads, including moderate overloads
IEC/EN 60947-1-3, 60947-5-1, • AC-22 Switching of mixed resistive and inductive loads, including moderate overloads
60204-1, specifications for the utili- • AC-23 Switching of motor loads or other highly inductive loads
zation categories.
• DC-1 Non-inductive or slightly inductive loads, resistance furnaces
• DC-3 Shunt-motors, starting, plugging, inching, dynamic breaking of motors
• DC-5 Series-motors, starting, plugging, inching, dynamic breaking of motors
• DC-12 Control of resistive loads and solid state loads with isolation by optocouplers
• DC-13 Control of d.c. electromagnets
• DC-20 Connecting and disconnecting under no-load conditions
• DC-21 Switching of resistive loads, including moderate overloads
• DC-22 Switching of mixed resistive and inductive loads, including moderate
overloads (e.g. shunt motors)
• DC-23 Switching of highly inductive loads (e.g. series motors)
Average full load currents of squirrel cage motors
(alternate current 4 poles 1500 rpm)

Ampére
kW
230V 400V 500V 690V
0,06 0,41 0,24 0,19 0,14
0,09 0,62 0,36 0,29 0,21
0,12 0,83 0,48 0,38 0,28
0,18 1,16 0,67 0,54 0,39
0,25 1,43 0,83 0,66 0,48
0,37 1,90 1,10 0,88 0,64
0,55 2,67 1,55 1,24 0,90
0,75 3,45 2,00 1,60 1,16
1,10 4,75 2,75 2,20 1,60
1,50 6,05 3,50 2,80 2,05
2,20 8,45 4,90 3,90 2,85
3,00 11,70 6,80 5,40 3,90
4,00 15,00 8,70 7,00 5,00
5,50 19,50 11,30 9,10 6,50
7,50 25,50 14,80 11,90 8,60
11,00 37,00 21,50 17,00 12,50
15,00 50,00 29,00 23,00 17,00
18,50 60,50 35,00 28,00 20,50
22,00 72,50 42,00 33,50 24,50
30,00 97,50 56,50 45,00 32,50
37,00 117,00 68,00 54,50 39,50
45,00 141,00 82,00 64,00 47,00
55,00 173,00 100,50 80,00 57,00
75,00 229,00 133,00 106,00 77,00
90,00 272,00 158,00 126,00 91,00
110,00 333,00 193,00 153,00 110,00
Series R
Front mounting - On-off switches

Standard handle

Rated current IP Dimensions 1 pole 2 poles 3 poles 4 poles 6 poles


Ie AC-21A (A) protection mm x mm 1 bank 1 banks 2 banks 2 banks 3 banks
0 45°
1
16 48 14.01.11 14.02.11 14.03.11 14.04.11

40 90°
0 54 13.01.11 13.02.11 13.03.11 13.04.11
20
1 13.01.11C 13.02.11C 13.03.11C 13.04.11C
72
25 1.01.11 1.02.11 1.03.11 1.04.11

32 RE321751A RE321752A RE321753A RE321754A RE321756A


64
40 RE401751A RE401752A RE401753A RE401754A RE401756A
50 RE501751A RE501752A RE501753A RE501754A RE501756A
1
90° 88
75 RE801751A RE801752A RE801753A RE801754A RE801756A
0
120 66 RE1251751A RE1251752A RE1251753A RE1251754A RE1251756A
200 RE2501752A RE2501753A RE2501754A RE2501756A
130
250 RE4001753A RE4001754A
315 RE6301753A RE6301754A

Padlockable handle

Rated current IP Dimensions 3 poles 4 poles 3 poles 4 poles


Ie AC-21A (A) protection mm x mm 2 banks 2 banks 2 banks 2 banks
20 0 90° 13.03.11-OZ 13.04.11-OZ 13.03.11-OM 13.04.11-OM
25 54 1 72 1.03.11-OZ 1.04.11-OZ 1.03.11-OM 1.04.11-OM

Rated current IP Dimensions 3 poles 4 poles 6 poles 3 poles 4 poles 6 poles


Ie AC-21A (A) protection mm x mm 2 banks 2 banks 3 banks 2 banks 2 banks 3 banks
32 RE321753G RE321754G RE321756G RE321753N RE321754N RE321756N
67
40 RE401753G RE401754G RE401756G RE401753N RE401754N RE401756N
50 1 90° RE501753G RE501754G RE501756G RE501753N RE501754N RE501756N
90
75 0 RE801753G RE801754G RE801756G RE801753N RE801754N RE801756N
66
120 RE1251753G RE1251754G RE1251756G RE1251753N RE1251754N RE1251756N
200 RE2501753G RE2501754G RE2501756G RE2501753N RE2501754N RE2501756N
135
250 RE4001753G RE4001754G RE4001753N RE4001754N
315 RE6301753G RE6301754G RE6301753N RE6301754N
Series R
Base mounting - on-off switches

Standard handle

Rated current IP Dimensions 3 poles 4 poles 6 poles


Ie AC-21A (A) protection mm x mm 2 banks 2 banks 3 banks
0 90° 54 13.03.11-3 13.04.11-3
20
54 1 13.03C-3 13.04C-3
72
25 1.03.11-3 1.04.11-3

32 RA321753A RA321754A RA321756A


64
40 RA401753A RA401754A RA401756A
50 90°
RA501753A RA501754A RA501756A
1 88
75 RA801753A RA801754A RA801756A
66 0
120 RA1251753A RA1251754A RA1251756A
200 RA2501753A RA2501754A RA2501756A
130
250 RA4001753A RA4001754A
315 RA6301753A RA6301754A

Padlockable handle

Rated current IP Dimensions 3 poles 4 poles 3 poles 4 poles


Ie AC-21A (A) protection mm x mm 2 banks 2 banks 2 banks 2 banks
20 0 90° 13.03.11-SP 13.04.11-SP 13.03.11-OP 13.04.11-OP
55 72
25 1 1.03.11-SP 1.04.11-SP 1.03.11-OP 1.04.11-OP

Rated current IP Dimensions 3 poles 4 poles 6 poles 3 poles 4 poles 6 poles


Ie AC-21A (A) protection mm x mm 2 banks 2 banks 3 banks 2 banks 2 banks 3 banks
32 RA321753G RA321754G RA321756G RA321753N RA321754N RA321756N
67
40 RA401753G RA401754G RA401756G RA401753N RA401754N RA401756N
50 RA501753G RA501754G RA501756G RA501753N RA501754N RA501756N
1 90° 90
75 RA801753G RA801754G RA801756G RA801753N RA801754N RA801756N
0
120 66 RA1251753G RA1251754G RA1251756G RA1251753N RA1251754N RA1251756N
200 RA2501753G RA2501754G RA2501756G RA2501753N RA2501754N RA2501756N
135
250 RA4001753G RA4001754G RA4001753N RA4001754N
315 RA6301753G RA6301754G RA6301753N RA6301754N
Series R
On-off switches

Central mounting Ø 22mm

Rated current IP Positions Control 2 poles 3 poles 4 poles 6 poles


Ie AC-21A (A) protection 1 bank 2 banks 2 banks 3 banks
0 90° handle 13.02.11-2M 13.03.11-2M 13.04.11-2M
20 1 key 13.02.11-2C 13.03.11-2C 13.04.11-2C

handle RC321752B RC321753B RC321754B RC321756B


32 66
1 90° key RC321752DD RC321753DD RC321754DD RC321756DD
0 handle RC401752B RC401753B RC401754B RC401756B
40 key RC401752DD RC401753DD RC401754DD RC401756DD

Thermoplastic enclosed switch, front actuator (130x95 h91mm)

Rated current IP Dimensions 3 poles 4 poles 3 poles 4 poles


Ie AC-21A (A) protection mm x mm
16 0 90° 14.03.11-5S 14.04.11-5S 14.03.11-5R 14.04.11-5R
20 54 1 13.03.11-5S 13.04.11-5S 13.03.11-5M 13.04.11-5M
25 1.03.11-5S 1.04.11-5S 1.03.11-5M 1.04.11-5M
32 2.03.11-5S 2.04.11-5S 2.03.11-5M 2.04.11-5M

Enclosed switch side lever

Rated current IP Fiber-glass filled IP Metal enclosure


Ie AC-21A (A) protection enclosure protection
3 poles 4 poles 3 poles 4 poles
20 13.03.11-5L 13.04.11-5L 13.03.11-4L 13.04.11-4L
25 1.03.11-5L 1.04.11-5L 1.03.11-4L 1.04.11-4L
32 54 2.03.11-5L 2.04.11-5L 55 2.03.11-4L 2.04.11-4L
50 3.03.11-5L 3.04.11-5L 3.03.11-4L 3.04.11-4L
75 4.03.11-5L 4.04.11-5L 4.03.11-4L 4.04.11-4L
120 5.03.11-4L 5.04.11-4L

 Yellow cover and red handle


Series R
Changeover switches

Front mounting - Standard handle

Rated current IP Dimensions 1 pole 2 poles 3 poles 4 poles


Ie AC-21A (A) protection mm x mm 1 bank 2 banks 3 banks 4 banks
16 48 14.05.11 14.06.11 14.07.11 14.45.11
0 45° 54 13.05.11 13.06.11 13.07.11 13.45.11
20 1 2
40 13.05.11C 13.06.11C 13.07.11C 13.45.11C
72
25 1.05.11 1.06.11 1.07.11 1.45.11
32 45°
RE323251A RE323252A RE323253A RE323254A
0 64
40 1 2 RE403251A RE403252A RE403253A RE403254A
50 RE503251A RE503252A RE503253A RE503254A
88
75 88RE803251A RE803252A RE803253A RE803254A
120 66 RE1253252A RE1253253A RE1253254A
0 60°
200 1 2 RE2503503A RE2503504A
130
250 RE4003503A RE4003504A
315 RE6303503A RE6303504A

Front mounting - Padlockable handle

Rated current IP Dimensions 3 poles 4 poles


Ie AC-21A (A) protection mm x mm 3 banks 4 banks
20 13.07.11-OZ 13.45.11-OZ
54 72
25 1.07.11-OZ 1.45.11-OZ
32 0 45° RE323253G RE323254G
1 2 67
40 RE403253G RE403254G
50 66 RE503253G RE503254G
90
75 RE803253G RE803254G
120 135 RE1253253G RE1253254G

Base mounting - Padlockable handle - Doorlock

Rated current IP Dimensions 3 poles 4 poles


Ie AC-21A (A) protection mm x mm 3 banks 4 banks
20 13.07.11-SP 13.45.11-SP
54 72
25 1.07.11-SP 1.45.11-SP
0 45°
32 1 2 RA323253G RA323254G
67
40 RA403253G RA403254G
50 66 RA503253G RA503254G
90
75 RA803253G RA803254G
120 135 RA1253253G RA1253254G
Series R
Changeover switches

Central mounting Ø 22mm

Rated current IP Positions Control 3 poles 4 poles


Ie AC-21A (A) protection 3 banks 4 banks
0 45° handle 13.07.11 - 2M 13.45.11 - 2M
1 2
20 key 13.07.11 - 2C 13.45.11 - 2C

66
handle RC323253B RC323254B
32
key RC323253DC RC323254DC
0 45° handle RC403253B RC403254B
1 2
40 key RC403253DC RC403254DC

Enclosed switch side lever

Rated current IP Fiber-glass filled IP Metal enclosure


Ie AC-21A (A) protection enclosure protection
3 poles 4 poles 3 poles 4 poles
20 13.07.11-5L 13.45.11-5L 13.07.11-4L 13.45.11-4L
25 1.07.11-5L 1.45.11-5L 1.07.11-4L 1.45.11-4L
32 55 2.07.11-5L 2.45.11-5L 54 2.07.11-4L 2.45.11-4L
50 3.07.11-5L 3.45.11-5L 3.07.11-4L 3.45.11-4L
75 4.07.11-5L 4.45.11-5L 4.07.11-4L 4.45.11-4L
120 5.07.11-4L 5.45.11-4L
Series R
Motor switches - Base mounting

Standard handle

REVERSING SWITCHES DAHLANDER SWITCHES


Rated Rated IP Dim. 3 poles 45°
For single phase 45° For single phase 45°
3 poles 45°
3 poles pole chan-45°
motor with ging and
current power Pe protect. mmxmm 1
0
2 auxiliary M 0 M motor with 1 0 2
Dahlander 1
0
2 reversing 1 0 1
Ie AC-21A (A) AC-23A (kW) winding A A capacitor switch 0 0
2 2
3 banks 3 banks 3 banks 4 banks 7 banks
16 5,5 40 48 14.08.11
54 13.08.11 13.32.11 13.37.11 13.09.11 13.11.11
20 7,5
40 13.08.11C 13.32.11C 13.37.11C 13.09.11C 13.11.11C
72
25 11 1.08.11 1.32.11 1.37.11 1.09.11 1.11.11
32 18,5 RE327303A RE327293A
64
40 22 RE407303A RE407293A
50 22 66 RE507303A RE507293A
88
75 30 RE807303A RE807293A
120 45 130 RE1257303A RE1257293A

Y SWITCHES
Rated Rated IP Dim. Y- reversing switch
current power Pe protect. mmxmm 0
Y 0 0 Y 0
Y Y Y
Ie AC-21A (A) AC-23A (kW) 4 banks 4 banks 4 banks 5 banks
45°-90° 60° 30°-60° 45°-90°
54 13.10.11 13.70.11 13.54.11 13.12.11
20 7,5
40 13.10.11C 13.70.11C 13.54.11C 13.12.11C
72
25 11 1.10.11 1.70.11 1.54.11 1.12.11
32 18,5 RE327323A RE327553A
64
40 22 RE407323A RE407553A
50 22 RE507323A RE507553A
88
75 30 66 RE807323A RE807553A
Y
0
120 45 130 RE1257503A
60°

Rated Rated IP Dim. For single phase motor 0


M
For remote M
0
M
current power Pe protect. mmxmm with auxiliary winding A control reverser A A

Ie AC-21A (A) AC-23A (kW) 2 banks 45° 2 banks 45°

54 13.29.11 13.30.11
20 7,5
40 13.29.11C 13.30.11C
25 11 72 1.29.11

Enclosed switch side lever

Rated Rated IP 3 poles 0 3 poles 0 Y switches Y


1 2 1 2 0
current power Pe protect. reversing switches Dahlander
Ie AC-21A (A) AC-23A (kW) 45° switches 45° 45°-90°
20 7,5 13.08.11 - 5L 13.09.11 - 5L 13.10.11 - 5L
25 11 1.08.11 - 5L 1.09.11 - 5L 1.10.11 - 5L
55
32 18,5 2.08.11 - 5L 2.09.11 - 5L 2.10.11 - 5L
50 22 3.08.11-5L 3.09.11-5L 3.10.11 - 5L
75 30 4.08.11-5L 4.09.11-5L 4.10.11 - 5L
120 40 54 5.08.11-4L 5.09.11-4L 5.10.11 - 4L
Series R
On-off switches - Front mounting

Rated current IP Positions Dimensions 1 pole 2 poles 3 poles


Ie AC-21A (A) Protection mm x mm

2 banks 3 banks 5 banks


16 0
1
48 14.57.11
2 54 13.57.11 13.60.11 13.61.11
20 40 3
45° 13.57.11C 13.60.11C 13.61.11C
72
25 1
2
3
1.57.11 1.60.11 1.61.11
32 0 RE325261A
66 64
40 45° RE405261A
0 1 2 banks 4 banks 6 banks
2 54 13.58.11 13.62.11 13.63.11
20 3
40 4 45° 13.58.11C 13.62.11C 13.63.11C
72
25 1
2
3
1.58.11 1.62.11 1.63.11
32 0 4 RE325271A
66 64
40 45° RE405271A
0 1 3 banks
2 54 13.59.11
20 5
4
3
40 45° 13.59.11C
72
25 1
2
3
1.59.11
32 0 4 RE325281A
66 5 64
40 45° RE405281A
0 1 3 banks 6 banks 9 banks
6 2 54 13.64.11 13.65.11 13.66.11
20 40 5 3
4 45° 72 13.64.11C 13.65.11C 13.66.11C
4 banks
16 7 0 1 48 14.67.11
40 6 2 54 13.67.11
20 5
4
3
45° 72 13.67.11C

1
2
1 bank 2 banks 3 banks 4 banks
54 13.41.11 13.42.11 13.43.11 13.44.11
20 40
45° 72 13.41.11C 13.42.11C 13.43.11C 13.44.11C
1
2
2 banks
3 54 13.38.11
20 40
45° 72 13.38.11C
1
2
2 banks 4 banks 6 banks
3 54 13.46.11 13.47.11 13.48.11
20 40 4
45° 72 13.46.11C 13.47.11C 13.48.11C
1
2
3 banks 6 banks 9 banks
3 54 13.49.11 13.50.11 13.51.11
20 40 6 5 4
45° 72 13.49.11C 13.50.11C 13.51.11C
12 5 banks
3
10 4 54 13.52.11
20 40 9
876
5
30° 72 13.52.11C
12 1 2 6 banks
11 3
10 4 13.53.11
9 5
876
30° 13.53.11C
Series R
Voltmeter / ammeter switches

Front mounting

VOLTMETER SWITCHES
3 phase for 3 for phase to phase for 3 phase for 1 phase
phase to phase of two 3-phase lines and 3 phase to phase and 3 phase to phase
Rated current IP Dimensions 0 RN 0 RS T1R1
0 RS RS
0 RN RN
0 RS

Ie AC-21A (A) protection mm x mm 2 banks SN 2 banks ST 4 banks S1T1 ST 3 banks ST SN 3 banks ST


TN TR R1S1 TR TR TN TR
45° 0 45° 0 45° 0 45° 45°

16 48 14.16.11 14.18.11 14.19.11


54 13.15.11 13.16.11 13.17.11 13.18.11 13.19.11
20 40
13.15.11C 13.16.11C 13.17.11C 13.18.11C 13.19.11C
72
25 1.15.11 1.16.11 1.18.11

Front mounting

AMMETER SWITCHES
For direct measure 1 pole for 1 1 pole for 3 1 pole for 4 2 poles for 3
without break current transformer current transformer current transformers current transformers
Rated current IP Dimensions 0 0 0 1 0

Ie AC-21A (A) protection mm x mm 5 banks T R 1 banks 1 3 banks 3 1 4 banks 4 2 5 banks 3 1

90° S 90° 90° 2 90° 3 90° 2

16 48 14.22.11
54 13.14.11 13.20.11 13.22.11 13.23.11 13.25.11
20 40
13.14.11C 13.20.11C 13.22.11C 13.23.11C 13.25.11C
72
25 1.14.11 1.22.11 1.25.11

DIN - RAIL mounting

45x54

45
64
80

VOLTMETER SWITCHES AMMETER SWITCHES


Rated current IP Dimensions for 3 phase 0 RS for 3 phase RS
0 RN 1 pole for 3 0
Ie AC-21A (A) protection mm x mm to phase ST and 3 phase to phase ST SN current transformers 3 1
TR TR TN
45° 0 45° 90° 2

20 40 54x45 13.16.11D 13.18.11D 13.22.11D


Series R
Accessories - handles and actuators
Series Code
Standard handle
Black - lenght 40mm 13 G1392N
Red - lenght 40mm 13 G1392R
Black - lenght 50mm 13, 1 G1527N

Black standard handle


Lenght 35 mm 13, 1 G3397N
Lenght 37,5mm R32, R40 L2-G3154N
Lenght 48mm R32, R40 L2-G3155N
Lenght 71mm R50, R80 RG3518N
Lenght 106 mm R125..R630 RG3519N
Red standard handle
Lenght 37,5mm R32, R40 L2-G3154R
Lenght 48mm R32, R40 L2-G3155R
Lenght 71mm R50, R80 RG3518R
Lenght 106 mm R125..R630 RG3519R
Black handle Ø 30mm 13, 1 G2536N
Red handle Ø 37mm 13, 1 G2057R
Black handle Ø 37mm 13, 1 G2057N
Black handle Ø 41mm 13, 1 G3587N
IP40 R32, R40 L2-G2851N
IP65 R32, R40 L2-G2854N
Handle with locking device R32, R40
black L2-G2864N
red L2-G2864R

Black lever 13, 1 G1529N


Orange lever 13, 1 G1529L
Orange lever R32, R40 G2865L
Black standard lever R125..R630 RG3520N
Red standard lever R125..R630 RG3520R
Actuator type N 72x72 mm yellow/red (for on - off switches with standard actuator) 13, 1 G2391
Actuator type N 67x67 mm yellow/red R32, R40 LFS2-N-6-175
Actuator type N 90x90 mm yellow/red R50, R80 LFSR-N-8-175
Actuator type N 135x135 mm yellow/red (with lever instead of handle) R125, R250 LFSR-N-13-175
Actuator type G 72x72 mm grey/black for on-off switches (0-1) with standard actuator 13, 1 G3818
Actuator type G 72x72 mm grey/black for change over sw. (1-0-2) with standard actuator 13, 1 G2393
Actuator type G 67x67 mm grey/black for change over sw. (1-0-2) with standard actuator R32, R40 LFS2-G-6-325
Actuator type G 67x67 mm grey/black for on-off switches (0-1) with standard actuator R32, R40 LFS2-G-6-175
Actuator type G 90x90 mm grey/black R50, R80 LFSR-G-8-175
Actuator type G 135x135 mm grey/black R125, R250 LFSR-G-13-175
Yellow legend plate 72mm, red handle for on-off switches 13, 1 G2397
Yellow legend plate 54mm, red handle for on-off switches 13 G2396

Actuator 54x54 mm neutral legend plate (without handle) 13, 1 G3455


Actuator 72x72 mm neutral legend plate (without handle) 13, 1 G3456

Actuator with guard 70x70 mm 13, 1 G2433


(Complete of legend plate 0-1 Ø57 mm)
Series R
Accessories
Series Code
Gaskets to obtain IP54 degree of protection for basic version IP40 13 G1683
13, 1 G1590

Central mounting Ø 22mm key operated removable 13 G2389N


in “0” position

Central mounting Ø 22mm key operated removable R32, R40 G3805 + LFC2-DD-001
in “0” position

Central mounting Ø 22mm handle operated 13 G2390N

Central mounting Ø 22mm handle operated R32, R40 G3805 + LFC2-B-001

Installation tool for tightening the central fixture nut (Ø 22mm) R32, R40 P3906

Panel hole adapter from Ø 30mm to Ø 22mm 13 G2326

Support for rear mounting 13 G1720


1 RG1722
R50, R80 RG1724
R125, R250 (max. 6 banks) RG1462
R125, R250 (max. 6 banks) RG1474
R400, R630 RG1474
Extension supports for rear mounting 13, 1, R50, R80 RG1761
Lenght: 35..171mm

Adapter plate for 4 fixing holes 68x68mm or 86x86mm R50, R80 REG3516
Adapter plate for 4 fixing holes 68x68mm or 104x104mm R125..R630 REG3517

DIN-rail mounting plate 13 G2535

Spacer for DIN-rail version (thickness 12,5 mm) 13 G2539

6,35 mm slip on terminal for screw terminals connection (M3,5) 13 1417

Device set to obtain a doorlock system from standard actuator


1 G2065
R32, R40 G3806
Series R
Accessories - Protections

Series Code
Terminal covers front mounting 13, 1 P21853
(3/4 poles) R32 RE32C4
R40 RE40C4
R50 RE50C4
R80 RE80C4
R125 RE125C4

base mounting 13 P21273


1 P20431
R32 RA32C4
R40 RA40C4
R50 RA50C4
R80 RA80C4
R125 RA125C4
Flexible shield
1 bank 13 G1466
1 P10889
R32, R40 REG3180
R50 REP10891
R80 REP10892
2 banks 13 G1466
1 P10889
R32, R40 REG3180
R50 REP10891
R80 REP10892
3 banks 13 G1467
1 P10890
R32, R40 REG3181
R50, R80 REP10892
4 banks 13 G1467
1 P10890
R32, R40 REG3181
R50 REP10892
R80 REP12792
5 banks 13 G1468
1 P12481
R32, R40 REG3182
R50 REP12792
6 banks 13 G1468
1 P12481
R32, R40 REG3182
R50 REP12792
Series R
Accessories

Series Code
Front installation shaft R32, R40
Lenght 34 mm Termoplastc (standard) L2-G3380
Lenght 34 mm Metal L7-G3688
Lenght 34 mm Termoplastic G3189
(to turn position 90° anti-clockwise)
Lenght 34 mm Termoplastic G3186
(to turn position 90° clockwise)
Base installation shaft R32, R40
Lenght 44 mm Termoplastic (standard) LA2-G2830
Lenght 44 mm Metal L7-G3687
Lenght 52 mm Termoplastic LA2-G3194
Lenght 52 mm Metal L7-G3707
Lenght 57 mm Termoplastic LA2-G3195
Modular shaft extension R32, R40 LA2-G2853
2 overlapping modules 24 mm
(Max 4 modules - total lenght 96 mm)

Metal shaft extension R32, R40


Lenght 110..235 mm LA2-G3393
Lenght 230..350 mm LA2-G3394
With yellow insert for on-off switches “0” h9
Insert for metal extension R32, R40 LA2-G3398
With red insert for on-off switches “0” h12

Grey insert to obtain a different start position “0” LA2-G3399


R32, R40

Clutch for doorlock R32, R40


“0” in position h12 P25394
“0” in position h9 P26747

Reducer for front installation shaft R32, R40 P3907

Series banks Code


Termoplastic enclosure - front actuator with guard 78x60 h 61mm 13 2 G3150

IP54
Termoplastic enclosure - side operated lever 122x97 h 79mm 13 6 G2401
1 6

IP55
Metal enclosure - side operated lever 113x95 h 85mm 13 5 G2403
1 5

IP55
Termoplastic enclosure - front actuator 130x95 h 91mm 13 4 G2533
1 4

IP54
Series R
Accessories - Legend plates

Central mounting Ø 22mm


29,5x41mm
0 1 OFF ON 1 0 2

P22850 NEUTRAL

P22921 P24447 P24720 P24143 NEUTRAL IN SILUMIN

54x54mm
0 OFF 1 0 2 0
MAN AUT
1 ON

P24894 P24906 P24890 P24897


0
RS
ST

0 TR
P24892 P24907 NEUTRAL

Series 13,1
72x72mm
0 OFF 0 0
1 2 MAN AUT
1 ON

P20688 P3813 P20673 P3814


0 0 1 0 1 0 1
1
2 2 2 6 2
3 3 5 3 5 3
4 4 4
P20706 P20772 P20764 P20742
1 1 1 1
2 2 2 2
3 3 3
4 6 5 4
P20699 P22456 P20701 P20733
0 RS RS
0 RN 0
ST ST SN 3 1
TR TR TN
0 2
P20704 P20686 P20690 P20830 NEUTRAL
Ø 57mm
0 0
1 2
1

P25175 P22714 P10433 NEUTRAL

Series 13 - Front plates (DIN-RAIL type) 45x54 mm


Handle operated
0 OFF 1 0 2 0
MAN AUT
1 ON

P25103 P25138 P25092 P25120


0 0 0
RS RS RN
ST ST SN 3 1
0 TR TR 0 TN 2
P25100 P25102 P25105 P24919 NEUTRAL
Key operated
0 OFF 1 0 2 0
MAN AUT
1 ON

P25053 P25088 P25042 P25070


0 0 0
RS RS RN
ST ST SN 3 1
0 TR P25050 TR 0 TN P25052 2 P25055 P24914 NEUTRAL
Series R
Mounting examples

Series R 32/40
Base mounting type

Series R 50/80/125…630
Base mounting type

Series R
Front mounting type

The drawings represents


only some mounting types
for additional details, please
see the relevant instruction sheets
Series R
Technical informations

ALTERNATING CURRENT (IEC / EN 60947-3) Series 14 13


Rated operational voltage Ue IEC-EN / UL-CSA V 440 690/600
Rated isolation voltage Ui IEC / UL-CSA V 440 690/600
Rated impulse withstand voltage Uimp IEC kV 4 6
Dielectric test voltage for 1 min.corresponding to Ui kV 2,5 2,5
Rated trequency Hz 50/60 50/60
Conventional free air thermal current Ith A 16 25
Conventional enclosed thermal current Ithe A 16 25
Power loss by 1 pole at Ithe W 0,34 0,3
Rated operational current Ie 690 V
AC-1 Non inductive or slightly inductive loads
A 16 (400V) 25
AC-21A Switching of resistive loads with slight overload
Rated power Pe
AC-23A Frequent switching of motors 230 V kW 4 5,5
or other higly inductive load 400 V kW 5,5 7,5
690 V kW - 11
AC-3 Squirrel - cage motors: starting and stopping 230 V kW 2,2 4
of running motors 400 V kW 3 5,5
690 V kW - 7,5
AC-4 Squirrel - cage motor starting, reversing, 230 V kW - 2,2
electric breaking, inching 400 V kW - 3
500 V kW - 3
Rated breaking capacity (AC-23A)
cos ϕ 0,45 per Ie ≤ 100A 230 V A 120 176
cos ϕ 0,35 per Ie > 100A 400 V A 90,4 176
690 V A - 100
Short circuit characteristic
Conditional rated short-circuit current 400/415 V kA 5 5
Max. fuse rated current (fuse type gG/gL) A 16 25
Rated short-time withstand current Icw (1s) kA 0,32 0,4
Rated short-circuit making capacity Icm kA - 1,5
AC-15 Control of AC electromagnetic loads A300

DIRECT CURRENT (IEC / EN 60947-3)


DC-20A Rated operational current Ie A 20
Rated operational current Ie A 10
DC-1 Non inductive or slightly inductive loads
V max per polo 60
DC-21A Switching of resistive loads with slight overloads
Rated power 24 V kW 0,3 
DC-23A Control of high inductive loads series and shunt motors 48 V kW 0,4 
60 V kW 0,6 
 The rounded values correspond to 110 V kW 0,8 
the numbers of poles to connect in series 220 V kW 1,2 
Rated operational current Ie 24 V A 10
DC-13 Control of electromagnets 48 V A 5
L/R = 40 ms 60 V A 3
110 V A 1,3
220 V A 0,5
380 V A 0,3
500 V A 0,2
DC-13 Control of DC electromagnetic loads Q300
Series R
Technical informations

1 R32 R40 R50 R80 R125 R250 R400 R630


690/600 690/600 690/600 690/600 690/600 690/600 690/600 690/600 690/600
690/600 690/600 690#/600 690#/600 690#/600 690/600 690/600 690/600 690/600
6 8 8# 8# 8# 8 8 8 8
2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5
50/60 50/60 50#/60# 50/60 50/60 50/60 50/60 50/60 50/60
25 32 45# 50# 80# 125 250 400 630
25 32 45# 50# 75# 120 200 315 500
0,6 0,8 1,4 1,5 2,8 5,3 10 13,6 25,5

25 32 40# 50# 75# 120 200 250 315

7,5 11 11# 15# 18,5# 30 37


11 18,5 22# 22# 30# 45 55
15 22 22# 30# 37# 55 75
5,5 7,5 7,5# 11# 15# 22 30
7,5 15 18,5# 18,5# 22# 30 37
11 18,5 18,5# 22# 30# 37 45
2,2 5,5 5,5 7,5 11 15 18,5
4 7,5 7,5# 11 15 22 30
4 7,5 11 15 18,5 30 37

204 296 296# 400# 484# 780 936


172 280 336# 336# 544# 656 804
136 196 196# 260# 316# 456 616

5 5 5# 5# 5# 6 8 12 15
25 35 40# 50# 63# 100 160 250 315
0,5 0,8 0,8 1# 1,5# 2,4 4 5 6,5
1,5 2 2 2,5# 3# 5 7 10 15

25 32 40 50 75 120 200
16 25 25 40 63 100 200

60 60 60 60 60 48 42

0,3  0,3  0,3  0,7  1 


0,5  0,5  0,5  1,4  2 
1  1  1  2  2,7 
2  2  2  3  4 
2,2  2,2  2,2  6  8 
14 16 16
7 8 8
4,2 4,8 4,8
1,8 2 2
0,5 0,6 0,6
0,4 0,4 0,4
0,3 0,3 0,3
#
Values approved by IMQ
Series R
Technical informations

UL / CSA Series 14 13 1 
General use 1 phase/2 poles, 3 phase/3 poles
Rated current 600 V A 20 16
Heavy Pilot Duty (AC) Code designation A 600
Standard Duty (DC) Code designation P 600
Rated operational power
Across the line AC motor starting
DOL-Rating 120 V HP 1,5
1 phase 2 poles 240 V HP 3 3
480 V HP 5 6 
600 V HP 5 7,5
3 phases 3 poles 120 V HP 2
240 V HP 5 6
480 V HP 10 12 
600 V HP 10 15

ENVIROMENTAL DATA
Ambient temperature: Operation: -25°C a +60°C
Storage: -40°C a +80°C

MECHANICAL DATA
Protection class according to IEC/EN 60529
Actuators IP40 IP40..IP55 IP40..IP55
Switch bodies IP00 IP00 IP00
Mechanical life Milion of operations 1 2 1,5
Terminal sizes according to IEC/EN 60947-1 gauge form
Min./max. wire cross section A2 A3 A3
Fine strands mm2 0,75/2,5 1/2,5 1/2,5
Solid or stranded mm2 0,75/2,5 1/4 1/4
Max. wire gauges according to UL/CSA (solid/stranded) AWG 14/14 10/12 10/12
Terminals Type screw screw screw
Thread M3 M3,5 M4
Screw driver size 2/1 3/2 3/2 3/2
recommended torque (Nm) 0,6 1,2 1,2 1,8

APPROVALS
CE-confirmal • • •
CSA (Canada) • •
IMQ (Italy) •
UL-Listed (USA)
UR (USA) •
• Approved as a result of test passed
 Only CSA approval  For CSA 220V e 440V Only UL approval
Series R
Technical informations

R32 R40 R50 R80 R125 R250 R400 R630

32 40 50 63 115 200 250 (315A at 480V) 315

2 2 3 5  7,5 10
5 5 7,5 10  15 20
7,5 10 15 20  30 40
10 15 20 25  35 50
5 5 7,5 10  15 25
7,5 10 15 20  30 50
20 25 30 40  60 75
20 25 40 50  75 100

Operation: -25°C a +60°C


Storage: -40°C a +80°C

IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66


IP20 IP20 IP00 IP00 IP00 IP00 IP00 IP00
1 1 1 1 1 1 0,5 0,5

A5 A5 A5 A5 B7
2,5/6 2,5/6 2,5/6 2,5/16 1,5/35
2,5/10 2,5/10 2,5/10 2,5/25 1,5/50
8/10 8/10 8/10 4/6 1/2
screw screw screw screw screw embedded hexagon embedded hexagon embedded hexagon
M4 M4 M5 2xM4 2xM6 M10 M12 M14
3/2 3/2 3/2 3/2 4/- hexagon 8 mm hexagon 10 mm hexagon 12 mm
1,8 1,8 2 1,2 2 10 14 19

• • • • • • • •
• • • • • • • •
• • •
• •
• • • • • •
Series R
Dimensions - Fixing holes

Front mounting
H

A C D

B L E G

Series L no. of banks A B C D E F G H max


1 2 3 4 5 6 7 8 (mm x mm)

14 - 32 - 54 - - - - 48 23,5 Ø 35
13 37 50 62 75 87 100 112 125 54 or 72 28 or 32 Ø 47 72 38 1,5
1 35 48 60 73 85 98 110 123 72 32 Ø59
R32
41 58,5 76 93,5 111 128,5 146 163,5 64 28 Ø 61 67 34
R40
R50 51 69 87 105 123 141 159 177
88 45 Ø 80 90 49
R80 60 87 114 141 168 195 222 249
4
R125 118x102
83 113 143 173 203 233 263 293
R250 118x191
130 55 135 - 120 70
R400 113 173 233 293 353 413 473 533
118x180
R630 143 233 323 413 503 593 683 773
36x36 o 48x48 42

B 14

A A
C
24
Ø 9,5
C
Ø 3,2
BODIES/ACTUATORS 20
Series 13, 1, R32, R40, R50, R80
BODIES/ACTUATORS 100
BODIES/ACTUATORS
Series 14 fixing
Series A B C Alternative fixing
for series 13, 1, R32, R40
13 32
1
9,5 3,2
R32 33 5,3
R40
R50
12 46 5,3
R80
BODIES/ACTUATORS
Series R125..R630
Central mounting Ø 22mm
1…6mm
+0,2
3,2 0

+0,4
24,1 0 Ø 30 C

+0,4
22,3 0

A L B

Series L N° of banks A B C
1 2 3 4 5 6 7 8
13 69 82 94 107 119 132 144 157 36 26 Ø 47
R32
86 103,5 121 138,5 156 173,5 191 208,5 41 28 Ø 61
R40
Series R
Dimensions - Fixing holes

Base mounting
S
1…6mm

A C A C D

F
L

T B Y L E G
X
B

Series L no. of banks if Y min then X if Y max then X IF S then T IF S then T


1 2 3 4 ≥ ≥ MIN. MIN.
13 43 56 68 81 29 29
150 150
1 42 55 67 80 75 75
R32
42,5 60 77,5 95 - - - - 2,5 150 9,5 90
R40
R50 59 77 95 113
75 150 78 150
R80 68 95 122 149
R125 -
123 153 183
R250 -
71,5 220 77,5 220
R400 - 183 - -
R630 - 243 - -

I
L L
M
Q O

M
ACTUATORS

ACTUATORS
P

R
BODIES

ACTUATORS BODIES
Series A B C D E F G H I L M N O P Q R
(mm x mm)

13 54 o 72 28 51x51 32 36 36
72 38 58 9,5
1 72 32 33
3,2 M4
R32 78x55 - - 70 15
64 28 67 34 - - 36 o 48 17
R40
R50
88 45 102x102 92 49 12 85 85
R80
-
R125
68 5,3 M5
R250
130 55 57x148 135 - 120 70 20 37 132
R400
R630
Diagrams

09 3 Poles dahlander switch 14 Ammeter sw. for direct 19 Voltmeter switch 1 phase and 3 phase to phase
SERIES R (13, 1) Y-T8 measure without break
7 4 5 19 11 1 N
01 1 Pole on-off switch 3 U-T1
15 4
W-T3
L1
L2
A V L1
L2
13 L3 16 L3
5 8 RN
0 RS

1
0
2 Z-T9 V-T2 X-T7 16 14 3 ST
10 8 2 12
L1 TR
45°
3-4 X 4
1 45° L2 11 12
1-2 15 16 11 12
L3 11-12 X X
0 13 14 3
Elements

3 4 10
Contact

0 1 15-16 X 16 12 2 9-10 X
1 4
13-14 X 7-8 X X
Pos. 90° 2 8
11-12 X L4 5 5-6 X
3
9-10 X L5 3-4
3 4 1
02 2 Poles on-off switch 1 3 7-8 X L6 1-2 X X
2 7 8
5-6 X

Elements
2

Contact

ST
TR
RS
RN
3 11 19 0
3-4 X 5
1 1 2
1-2 X 19-20 X X Positions
5
3 4 17-18
Contact
Element

2 4 1 0 2
3-4 X 15-16 X X 20 1 Pole ammeter switch for 1 current transformer
1 Pos. 4
1-2 X 13-14 X X
0 11-12 X X
Elements

3 4 3
Contact

0 1 9-10 0
1 10 Star-Delta switch X X L1
Pos. 90° 1 2 7-8 X X 1
2 90°
5-6 X X 2
U-T1 Y-T8 3-4 X X
1 3 7 15 7 L1 1 1 A 3
03 3 Poles on-off switch 1-2 X X 90° 3-4 X X
L2 1
0 1-2 X X

Elements
Z-T9 5 4 W-T3

Contact
L3 0 R S T

Elements
13 8 T R 3

Contact
0 1
Y V-T2 X-T7 16 14 3 Positions S
0
Pos.
1 2
2 4 8 45°
7-8 X 90° 15 16 15 3 Phase voltmeter switch
2 22 1 Pole ammeter switch for 3 current transformers
5-6 7 8 13 14
15-16 X X 0 RN 3 7
3-4 X 4
1
1-2 X
13-14
11-12
X X
X TN
SN V L1
L2
0 3 0 45° 12
3 4 L3
Contact
Element

0 1 9-10 X
1
1 2 7-8 X 9
Pos. 90° 2 7-8 X X X
5-6 X 7 8 2 8 12 2
5-6 X 7 8
3-4 X X 5 8
04 4 Poles on-off switch 1 3 5 7 1 3-4 X 6 9 A 1
1-2 X 1
1-2 X
3 4
Contact
Element

0 Y 3 4
Contact
Element

RN
SN
TN

0 0
Pos.
Positions
2 11-12 X X
3 1 2
2 4 6 8 9-10 X X
7-8 X 11 Pole changing reversing switch 7-8 X X
2 16 3 Phase to phase voltmeter switch 2
5-6 X X
5-6 X 7 8 Y-T8
3-4 X 3 7 3-4 X X
5 6 0 RS 1
1
1-2 X
U-T1
10
W-T3
L1 ST V 1-2 X X
0

Elements
0

Contact
4 25 TR
3 4 L2 0 45° 0 1 2 3
Contact
Element

0 1 1 0 3 1
1 2
1 1
15 L3
Pos. 0 0 5 9 Positions 2 90°
90° 7-8 X
2 2
45° Z-T9 V-T2 X-T7 23 19 3 2
5-6 X X 7 8
05 1 pole changeover switch 3-4 X 6 23 1 Pole ammeter switch for 4 current transformers
25 1
27-28 1-2 X X
7 23
25-26 X X
Elements

3
Contact

RS
ST
TR

3-4 X 23-24 X X 0 0 L1
1 6 2 L2
1-2 X 21-22 X X Positions
0 19 L3
3 4 19-20 X X
Contact
Element

1 2
1 0 2 5 L4
17-18 X X 17 Voltmeter switch 3 Phase to phase of 2-3 phases lines
Pos.
2
45° 15-16 X X 15
4 4 12 2 6
13-14 X X 7 15
06 2 Poles changeover switch 3
11-12 X X V 15 A 7 15
9-10 X X T1R1
0 RS
7-8 9 10 S1T1 ST
7-8 X 2
2 5-6 X X R1S1 TR
45°
5-6 X 7 8 0 15 16 12
3-4 X X
3-4 X 6 1 5 14
1 1-2 X X 15-16 X X
1-2 X 4
Elements

3 4 13-14 X X
Contact

0
3 4 2 0 1 0 1 0 2 12 7
Contact
Element

1 2
1 0 2 11-12 X
2 Positions 3 10 6
Pos. 9-10 X
45°
7-8 X
12 Star-Delta reversing switch 2 7 4
5-6 X
07 3 Poles changeover switch 3-4 X X 2
U-T1 Y-T8 1
L1 1-2 X X 15-16 X X
11 12 4 8
4
S1T1
T1R1
R1S1

X 4 2 8 6 12 10
Elements

11-12 L2 4
Contact

13-14 X X
RS
ST
TR

3 0 0
9-10 X 10 0 Z-T9 7 10 W-T3 L3 11-12 X X
Y Y
12 5 Positions
2 3
7-8 X 45° 9-10 X X
2 3 7 11 7 8 V-T2 X-T7 19 15 3
5-6 X 90° 7-8 X X
3-4 X 18 Voltmeter switch 3 phases and 3 phase to phase 2
1 6 19 5-6 X X
1-2 X 19-20 X X 3-4 X X
5 1
0
3 4 17-18 X X 11 9 1-2 X X
Contact
Element

1 0 2 1 2 N
15-16 X X 15 V 1
Elements

4 L1
Contact

Pos.
2 13-14 X X 1 2 3 4
45° L2 4 2
11-12 X X Positions 3 90°
3 0 RN L3
9-10 X X 12 RS
08 3 Poles reversing switch 7-8 X X
ST SN
2 12 8 4
2 10 TR TN
5-6 X X 45°
11 12 7 8
3-4 X X X X 11 12
11-12 X X 1 11-12 X X
3 1-2 X X 5 3
9-10 9-10 X 9
Elements

3 4
Contact

7-8 X Y 0 Y 7-8 X
2 11 7 3 7 8 2
5-6 X 5-6 X X 8
Positions
3-4 X 3-4 X X X
1 1
1-2 X 1-2 X X
0
3
Contact

Elements
Element

1 2
1 0 2 4
SN
TN
Contact

RN
RS
TR
ST

0
Pos. 45° 2 2
Positions
Diagrams

25 2 Poles ammeter switch for 3 current transformers 41 1 Pole step switch 2 positions 50 2 Poles step sw. 6 positions 54 Star-Delta switch
3-4 X 1 U-T1 Y-T8
A 1 2
15 7 L1
L1 19 12 1-2 X 3
L2
L2 1

Elements
6 5 4
3 4 Z-T9 5 4 W-T3

Contact
1 2 2 45° L3
L3 23 24 13 8
Pos. 2 V-T2 X-T7 16 14 3
23-24 X 22 0 Y
11 20 13 14 5 2 6
19 20 21-22 X 15°
42 2 Poles step switch 2 positions 20
19-20 X 30° 15 16
5 18
7-8 X 17-18 X
2 15-16 X 13 14
5-6 X 7 8 16 15-16 X X
4 4
3-4 X 13-14 X 13-14 X X
13 14 1 6 14
1-2 X 11-12 X 11-12 X
3 11 12 3
1 9-10 X 9-10 X

Elements
11 3 4

Contact
12 1 2 2
7-8 X 7-8 X X
2 10 2
Pos.
2 5-6 X 5-6 X X 7 8
23-24 8
6 3-4 X 3-4 X X 5
21-22 X X 1 6 1
43 3 Poles step switch 2 positions 1-2 X 1-2 X
19-20 X X

Elements

Elements
5 4 3 4

Contact
5

Contact
17-18 X X 1 2 3 4 5 6 0 Y
11 12
15-16 X X 11-12 X Positions
2
4 3 10
Pos.
13-14 X X 9-10 X
11-12 X X 2 7-8 X
3 2 7 8 51 3 Poles step sw. 6 positions 55 Star-Delta reversing switch
9-10 X X 5-6 X
7-8 3-4 X 6
2 1 1 U-T1 Y-T8
5-6 X X 1-2 X 2
L1
1 3 35 36 15 7
ElementS

3-4 3 4 L2
Contact

2
1 1 2 6 5 4
45°
1-2 X X 34 Z-T9 5 4 W-T3 L3
Pos.
2 13 8
0 45° 32
Elements

Contact

0 1 2 3 35-36 X V-T2 X-T7 19 15 3


3 1 9 30
33-34 X
Positions 2 90° 44 4 Poles step switch 2 positions 31-32 Y 0 Y
X 28
8 15° 19
15 16 29-30 X
29 Single phase motor switch + aux. winding 15-16 X 26 30°
4 14 27-28 X
13-14 X 7 23 24
U1 Z1 25-26 X
L1 11-12 X 11 12 23-24 X 19-20 X X 15
6 8 4 3 6 22 5
L2 9-10 X 21-22 X 17-18 X X
10 20
7-8 X 19-20 X 15-16 X X
5 7 2 5 4
5-6 X 7 8 17-18 X 18 13-14 X X
9 1 12
3-4 X 15-16 X 11-12 X X
1 6 4 16 3 10
0
M U2 Z2 1-2 X 13-14 X 9-10 X X
1 14 7-8 X X
Elements

A 3 4 11-12 X
Contact

2
Avv. ausiliario

1 2 3 2
45° 9-10 X 11 12 5-6 X X 7 8
2
Pos. 45° 7-8 X 3-4 X X X X 5
2 10 1
7-8 X X 5-6 X 1-2 X X
2 8
7 8 45 4 Poles changeover switch

Elements
5-6 X X 3-4 X 3 4

Contact
1 Y 0 Y
3-4 X 5 6 1-2 X 6
1 15 16 Positions
1-2 15-16
Elements

X 4
Contact

4 14 1 2 3 4 5 6
Elements

4 13-14 X
Contact

0 M A 2
11-12 X 11 12 Positions 57 1 Pole step sw. 3 positions + 0
Pos. 3
9-10 X 0
10 52 1 Pole step sw. 10 positions 1
7-8 X
2 2
30 Changeover sw. for remote control reverser 5-6 X 7 8 12 19 20 3
3-4 3 45°
X
Self-input 5 6 1 6 10 4
18
1-2 X 9
876
5
M
0
M 30° 7-8 X
0 16 2
Elements

3 4
Contact

A A Impulse ahead 3 1 0 2 1 2
5-6 8
45° 2 19-20 X 14 3-4 X
Impulse behind 1 Pos. 45° 5
17-18 1
X 12 1-2 X
15-16 X

Elements
4 4

Contact
7-8 46 1 Pole step sw. 4 positions 13-14 X 10 0 1 2 3
2
5-6 X X X X 11-12 X 8 1 2
Pos.
3-4 X 3
1 7-8 X 9-10 X 6
1-2 X 2 7 8 7-8
5-6 X X 58 1 Pole step sw. 4 positions + 0
2 4
Elements

Contact

A M 0 M A 3-4 X 6 5-6 X
1 3-4 0
1-2 X X 2 1
Positions 1
1 1-2 X 2
Elements

4
Contact

2
1 2 3 4 3
Elements

3 4 45°
Contact

32 Single phase reversing sw. + aux. winding 4 2 1 2 3 4 5 6 7 8 9 10


Pos. 45°
Positions 7-8 X
U1 Z1 L1 2
47 2 Poles step sw. 4 positions 5-6 X 7 8
11 5 L2
15 16 53 1 Pole step sw. 12 positions 3-4 X 6
10 12 1
15-16 X 1-2 X
4 14 23 24
13-14 X
Elements

4
Contact

9 1 0 1 2 3 4
0 11-12 X 12 22
M M 3 2
A A U2 Z2 9-10 X Pos.
10 20
45° 7-8 X
Auxiliary winding

2 18
5-6 X 7 8 59 1 Pole step sw. 5 positions + 0
11 12 3-4 X 16
11-12 X X X X 1 6
3 9 10 1-2 X 0 1
9-10 X X X X 14
1 2
Elements

7-8 X 4
Contact

2
2 1 2 3 4 12 5
4
3
5-6 X
3 45°
Pos. 4 2
3-4 X 5 45° 10
1 11-12
1-2 X 8 3
9-10 X 9 10
48 3 Poles step sw. 4 positions
Elements

Contact

A M 0 M A 6 7-8 X
12 1 2
2 8
1 11 3 4 5-6 X
Positions 23 24 10 4
9 5 3-4 X 6
23-24 X 22 876
30° 2 1
6 1-2 X
37 Reversing sw. single phase motor + capacitor 21-22 X
Elements

20 4
Contact

19-20 X 23-24 X 0 1 2 3 4 5
V1 U1 V U 5 18 6
17-18 X 21-22 X 2
L1 Positions
7 2 10 4 15-16 X 15 16 19-20 X
L2 4 5
13-14 X 17-18 X
3 9 11-12
14 60 2 Poles step sw. 3 positions + 0
X 15-16 X
3 12 4
9-10 X 13-14 X 0
1
7-8 X 10 11-12 X 2
2 3 3
5-6 X 9-10 X 45°
7 8
11-12 3-4 X 7-8 X
X 1 2 12
3 9 10 1-2 X 6 5-6 X 11-12 X
9-10 X X 3
1 9-10 9 10
Elements

4 3-4 X X
Contact

7-8 X 2
1 2 3 4 1
2 7
3
1-2 X 7-8 X
5-6 X 4 2 2
Pos. 45° 5-6 X 8
Elements

3-4 X X
Contact

1 1 2 3 4 5 6 7 8 9 10 11 12 3-4
1-2 X X 6
1
0 49 1 Pole step sw. 6 positions Positons 1-2 X
Elements

3 4
Contact

1 2
1 0 2
Elements

3 4
Contact

2 1 0 1 2 3
2
Pos. 45° 2
3
Pos.
6 5 4
45°
38 1 Pole step switch 3 positions
11 12
11-12 X
3 10
9-10 X
7-8 7-8 X
2 2
5-6 X 5-6 X 8
3-4 X 6 3-4 X 6
1 1
1-2 X 1-2 X
1
Elements

Elements

3 4 4
Contact

2
Contact

1 2 3 3
1 2 3 4 5 6
Pos.
2 2
45° Positions
Diagrams

61 3 Poles step sw. 3 positions + 0 65 2 Poles step sw. 6 positions + 0 3254 4 Poles changeover switch
0
1
SERIES R (R32..R630)
2 20
0 1 3 1 7 5 11 9 15 13
3
45°
6 2 1751 1 Pole on-off switch 1
5 3
4 45°
24
19-20 X 16 2 6 10 14
5 23-24 X 21 22
17-18 6
13 14 21-22 X
15-16 X 20 2
4 19-20 X 1-2 X
13-14 X 5 1 13 14
11 12 17-18 X 18 3-4
11-12 X 1 15

Elements
3 15-16 X 1 2

Contact
9-10 X 9 10 4 16 0 1 13-14 X
13-14 X 0 4
7-8 X 14 15-16 X
2 11-12 X Pos. 90° 9 10
5-6 X 8 3 9-10 X
9-10 X 11 12 3 11
3-4 X 6 11-12 X
1
1-2 X
7-8 X 10 1752 2 Poles on-off switch 1 3 5-6 X
2 2
5-6 X 7-8 X 5 6
Elements

4 8
Contact

0 1 2 3 3-4 X
1 1-2 X 7
2 1-2 X 6 1
Pos. 3-4 X
Elements

4
Contact

0 1 2 3 4 5 6 0

Elements
1 2

Contact
2 4 1 2
1 0 2
62 2 Poles step sw. 4 positions + 0 2 1-2 X
Positions 1 3
3-4 X Pos. 45°
0 1

Elements
1 1 2

Contact
0 1
2 66 3 Poles step sw. 6 positions + 0 0
3503 3 Poles changeover switch
4
3
45° 3 4
15 16 Pos. 90°
0 1
14 3 1 5 7 11 9
15-16 X 6 2 35 36 1753 3 Poles on-off switch 1 3 5
4 5 3
13-14 X 4 45° 34
12
11-12 X
3 10 32 2 8 10
9-10 X 35-36 X
7-8 9 30
X 33-34 X
2 7 8 2 4 6 9 10
5-6 X 31-32 X 28 9-10 X
3-4 8 5-6 X 3
X 6 29-30 X 11-12 X 11
1 26 2 5 6
1-2 X 27-28 X 7-8 5-6 X
7 23 24 1-2 X 2
25-26 X
Elements

4 7-8 X 5
Contact

0 1 2 3 4 1
23-24 X 22 3-4 X 1-2 X
Pos.
2 6
Elements
1 1 7 8
21-22 X 1 2
20 Contact 0 1 0
3-4 X
19-20 X 0

Elements
5 3 4 1 2

Contact
17-18 X 18 Pos. 90° 1 0 2 1 2
63 3 Poles step sw. 4 positions + 0
15-16 X 3
4 16 Pos. 60°
0
23 24 13-14 X 1754 4 Poles on-off switch 1 3 5 7
1 14
2 22 11-12 X 3504 4 Poles changeover switch
3 11 12
4
3
45° 9-10 X
20 7-8 X 3 1 5 7 11 9 13 15
2 10
23-24 X 18 5-6 X
6 8 2 4 6 8
21-22 X 3-4 X 0
1 6 5-6 X 1 2
19-20 X 15 16 1-2 X 2 2 8 10 16
5 7-8 X 5 6
Elements

17-18 X 4 60°
Contact

14 0 1 2 3 4 5 6 1-2 X
15-16 X 1 7 8
4 Positions
2 3-4 X 13
13-14 X 13-14 X
12 1 4 15 16
Elements

1 2
Contact

11-12 X 0 1 15-16 X
3 10 67 1 Pole step sw. 7 positions + 0 0
9-10 X 3 4 9-10 X 9 10
Pos. 90° 3
7-8 X 11-12 X
2 7 8 7 0 1 11
5-6 X 6 2 5-6 X
3-4 X 1756 6 Poles on-off switch 1 3 5 7 9 11 2
7-8 X
1 6 5
4
3
45° 5
1-2 X 16 1-2 X
1 7 8
Elements

4 3-4 X
Contact

0 1 2 3 4 15-16 X
4 Elements 1 2
Contact
Pos.
2 13-14 1 0 2
12 2 4 6 8 10 12
11-12 X 3
3 10 Pos.
9-10 X
64 1 Pole step sw. 6 positions + 0 7-8 9 10
X 9-10 X
2 8 3 5261 1 Pole step switch 3 position + 0 3 1 5
0 1 5-6 X 11-12 X 11 12
6 2 3-4 X 6 5-6 X 2
5 3 1 2 1 3
4 45° 1-2 X 7-8 X 5 6 0
Elements

3 4 1-2 X
Contact

11 12 0 1 2 3 4 5 6 7 7 8 45°
11-12 X 1 4
3 2 3-4 X
9-10 X 10 Positions 1 5-6 X
Elements

1 2
Contact

7-8 0 1 2
X 0 7-8 5
2 8 3 4
5-6 X 70 Star-Delta switch Pos. 90° 1-2 X
3-4 X 1
1 6 U-T1 Y-T8 L1 3-4 X
1-2 X 3251 1 Pole changeover switch
Elements

15 7 L2 1
Contact

0 0 1 2 3
Elements

4 Y
L3
Contact

0 1 2 3 4 5 6 Z-T9 5 4 W-T3 3 1 Pos.


3 4
Positions
2 60° 13 8 16 14 3
V-T2 X-T7
15-16
5271 1 Pole step switch 4 positions + 0 3 1 7 5
X X 15 16
4
13-14 X X 2 2
13 14 1-2 X 1 3
11-12 X
3 1 0 4
9-10 X 3-4 X
0 45°
7-8
Elements

X 1 2 8
Contact

1 2
2 1 0 2
5-6 X
7 8 Pos.
3 5-6 X
3-4 X X 45° 2
1 7-8 X 5
1-2 X 5
1-2 X
3252 2 Poles changeover switch 3 1 7 5 1 7 8
Elements

3 4
Contact

Y 0 3-4 X
Elements

1
Contact

Pos. 0 1 2 3 4
Pos.
3
2 6
5-6 X
2
7-8 X 5 6 5281 1 Pole step switch 5 positions + 0
3 7 5 11 1
1-2 X 7 2
1 1 3
3-4 X 0 4
0
Elements

1 2 5
Contact

1 2
1 0 2 45°
3 12
Pos. 45°
9-10
3
11-12 X
3253 3 Poles changeover switch 11 12
5-6 X
2
7-8 X 5
3 1 7 5 11 9 1-2 X
1 7
3-4 X
Elements

1
Contact

0 1 2 3 4 5
2 6 10 3
Positions

9 10
9-10 X
3 11
11-12 X
5-6 X
2 5 6
7-8 X
1-2 X 7
1
3-4 X
0
Elements

1 2
Contact

1 2
1 0 2
Pos.
3
45°
Diagrams

7293 3 Poles Dahlander switch 08 3 Poles reversing switch 45 4 Poles changeover switch
1U
SERIES 14 U1 4 2 8 6 12 10 16 14
6
L1 01 1 Pole on-off switch 1 10
L1
2U 2W
14 1 L2 L2
L3 L3 1 5 9 13
5 16 8
1
0
2
6 4
1W 2V 1V 13 15 2 V1 W1 9 5 1 13 14
3-4 X 2
45° 1 13-14 X 16
1-2 4
13 14 0 9 10 15-16 X

Elements
13-14 1 1 2

Contact
X 0 1 9-10 X X 9 10
4 15 16 3 9-10 X
15-16 X 11-12 3
Pos. 45° 11-12 X 12
9-10 X 5-6 X
3 2 5-6 X
11-12 X 7-8 X 5 6 2
02 2 Poles on-off switch 1 3 7-8 X 5 6
5-6 X 1-2 X
2 1 1-2 X
7-8 X 5 6 3-4 X 1 8
3-4 X
1-2 X 0

Elements
1

Contact
1 1 2
8 1 0 2 0

Elements

Contact
3-4 X 1 2 1 2
1 0 2
Pos.
4
Elements

1 2 45° 4
Contact

1 0 2 2 4 Pos. 45°
1-2 X
Pos.
1 16 3 Phase to phase voltmeter switch
3-4 X
0 57 1 Pole step switch 3 positions + 0
Elements

1 1 2
Contact

0 1 L1 2 4 6
7303 3 Poles reversing switch 0 RS
5 1
3 4 L2
U1
Pos. 45°
0
TR
ST

45°
V L3
0
1
2
11 3
03 3 Poles on-off switch 1 3 5 6 4 8 45°
L1
3
0 L2 5-6 X
1 2 2 5 6 5-6 X
L3 7-8 X X 2
5 3 7-8 6
1-2 X 8
45° V1 W1 12 6 2 1 1-2 X
2 4 6 3-4 X X 1
3-4 X
9-10

Elements
5-6 1

Contact
X

RS
ST
TR
3 0 0

Elements
12 2 2

Contact
11-12 X X 11 7-8 5 6 0 1 2 3
Positions
4
5-6 X 1-2 X 3 4
2 Pos.
7-8 X 5 6 1
3-4 X
1-2 X 18 Voltmeter switch 3 phase and 3 phase to phase
0 67 1 Pole step switch 7 positions + 0
Elements

1 1 1 2
Contact

3-4 X 0 1
3 4 2 4 6 8 10 12 14
Elements

2 Pos. 13 5 N
Contact

1 0 2 45°

Pos.
3 V L1
04 4 Poles on-off switch 1 3 5 7 L2
7 0 1
0 RN L3
7323 Star-Delta switch RS 6 2 1
ST SN 5 3
TR TN
4 14 10 12 4 45° 14
W2 U1 45°
6 14 L1 2 4 6 8 13-14 X
L2 13 14 4
5-6 X 15-16
W1 1 8 U2 L3 2 13-14 X X 10
Y 5 16 7-8 X 5 6 4 9-10 X
0 15-16 X X 3 12
V2 V1 13 15 2 1-2 X 11-12 X
45° 1 7 8 9-10 X 10
3-4 X 3 5-6 X
90° 11-12 X 12 2 6
0 7-8 X
Elements

1 1 2
Contact

13 14 0 1 5-6 X X
13-14 X X 2 1-2 X 8
4 15 16 3 4 7-8 X X 5 1
15-16 X X Pos. 45° 3-4 X
1-2 X

Elements
9-10 1 1 2

Contact
X 3-4 X 0 1 2 3 4 5 6 7
3 05 1 Pole changeover switch
11-12 X 4 2 4
Elements

SN
TN
Contact

RN

Positions
RS
TR
ST

5-6 X 0
2 4
7-8 X 5 6 Positions
1-2 X X
1 8 1
3-4 X 19 Voltmeter switch 1 phase and 3 phase to phase
1-2 X
Elements

1 2 1
Contact

0 Y 3-4 X
0 9 3 N
Elements

Pos. 1 2
V
Contact

1 2
1 0 2
L1
4
7503 Star-Delta switch Pos. 45° L2
0 RS L3
W2 U1 RN
6 14 L1 06 2 Poles changeover switch ST
12 6 4 10
L2 4 2 8 6 TR
45°
W1 1 8 U2 L3
Y 5 16 9 10
0 9-10
V2 V1 13 15 2 X X
3 12
1 5 11-12 X
60°
5-6 X 5-6 X X
13 14 2 6
13-14 X X 2 5 6 7-8 X
7-8 X
4 15 16 1-2
15-16 X X 1-2 X 8 1
9-10 X 1 3-4 X X
3-4 X
3
Elements

11-12 X
Contact

ST
TR
RS

0
RN
Elements

1 2 0
Contact

1 2
1 0 2
5-6 X 3 4
2 4 Positions
7-8 X 5 6 Pos. 45°
1-2 X X
1 8 22 1 Pole ammeter switch for 3 current transformers
3-4 X 07 3 Poles changeover switch
4 2 8 6 12 10
Elements

1 2
Contact

0 Y
L1
Pos. L2
L3
1 5 9
7553 Star-Delta switch
9 10 10 4 8 13
9-10 X
W2 U1 3 12 A
11-12 X 15 5 10
6 14 L1
5-6 X
L2 2
7-8 X 5 6
W1 1 8 U2 L3
5 16 1-2 X 8
1 13-14 5
0 V2 V1 13 15 2 3-4 X 4
Y 0 15-16 X X 8
Elements

1 2
Contact

1 2
1 0 2 9-10 X X
13 14 4 3
Pos. 45° 11-12 X X
15 16 5-6 X X 4
13-14 X X 2
4 7-8 X X
15-16 X X
1-2
9-10 X 1
3 3-4 X X
11-12 X 0
Elements

Contact

5-6 X 0 1 2 3
2 5 6
3 1
7-8 X
Positions 2 90°
1-2 X X 8
1
3-4 X
Elements

1 2
Contact

Y 0
Pos.
Series R
Circuit diagrams

30° Date Order N.


60°
Company
Contact
Ph. Fax
45°
Quantity Delivery date
90°
31 32
31 - 32 29 30
8
29 - 30 27 28
27 - 28
7 25 26
25 - 26

from 20A to 25A


23 - 24 23 24
6
21 - 22 21 22
19 - 20 19 20
5
17 - 18
17 18
15 - 16
4 15 16
13 - 14
11 - 12 13 14
3
9 - 10 11 12
7-8 9 10
2
5-6
7 8
3-4
1 5 6
1-2
3 4
Banks

Contacts 1 2
Positions

29 - 30 29 30
8
31 - 32 31 32
from 32A to 315A

25 - 26
7 25 26
27 - 28
27 28
21 - 22
6 21 22
23 - 24
17 - 18 23 24
5
19 - 20 17 18
13 - 14
4 19 20
15 - 16
13 14
9 - 10
3
11 - 12 15 16

5-6 9 10
2
7-8 11 12
1-2
1 5 6
3-4
7 8
Banks

Contacts 1 2
Positions
3 4

X Contact closed XX Contact closed in several positions Spring return

Rated current Ie AC-21A (A) Front mounting Base mounting

Actuator

Notes
Series R
Ordering example for special switches
30° Order N. 0000/00
0 Date
60°
M Company Rossi & Bianchi
Contact Rossi
A
Ph. 02 555555 Fax 02 555555
45° X 10 pieces 1 week
Quantity Delivery date
90°
31 32
31 - 32 29 30
8
29 - 30 27 28
27 - 28
7 25 26
25 - 26

from 20A to 25A


23 - 24 23 24
6
21 - 22 21 22
19 - 20 19 20
5
17 - 18
17 18

e
15 - 16
4 15 16
13 - 14
11 - 12 13 14
3
9 - 10
2

1
7-8
5-6
3-4
1-2
X X
X
X
X
0 M A
pl 11

3
12

10

4
am
Banks

Contacts 1 2
Positions

29 - 30 29 30
8
31 - 32 31 32
from 32A to 315A

25 - 26
7 25 26
27 - 28
27 28
Ex

21 - 22
6 21 22
23 - 24
17 - 18 23 24
5
19 - 20 17 18
13 - 14
4 19 20
15 - 16
13 14
9 - 10
3
11 - 12 15 16

5-6 9 10
2
7-8 11 12
1-2
1 5 6
3-4
7 8
Banks

Contacts 1 2
Positions
3 4

X Contact closed XX Contact closed in several positions Spring return

Rated current Ie AC-21A (A) 20 X Front mounting Base mounting

Actuator 54 x 54mm (Standard) - complete of legend plate

Notes
Special version

Changeover Sw. 4x1600A

Disconnector Sw. 2200A


visit our web site:
www.breter.it
www.breter.it

Breter s.r.l.
Via Cardinale Riboldi, 161
I - 20037 Paderno Dugnano - Milano
Italy
Tel. +39 0299061.1
Fax +39 029103516

Cam switches R series - 9/2003