Weather Station
6 Reference Quality Parameters
Key Features
   Wind Speed & Direction                                                 Barometric Pressure
   Temperature                                                            Dew Point
   Humidity                                                               Rugged, Professional Design
MetPak weather station utilises Gill WindSonic ultrasonic technology,
a highly accurate barometric pressure sensor and a Rotronic Hygroclip
HC2-S3-GI temperature/humidity probe.
The design of the MetPak allows measurements to be as accurate as
possible without influencing other measured parameters yet provides a
compact, reference quality system. The unit is especially suitable for harsh
or marine environments and is supplied with selectable Gill ASCII, NMEA
SDI-12 and Modbus outputs..
                                Base Station Options Available
                                MetPak can be configured with a remote wind sensor.
                                See page 3 for all wind sensor options.
 MetPak                                                                                                   Included:
                                                                                                           MetSet configuration software
                                         142mm (5.6")
                                                                                                           MetView data logging/visualisation
                                                                                                            software
                                                                                                           Mounting kit to adapt to poles or masts
                                                                                                           Selectable ASCII, NMEA, SDI-12
                                                                                                            or Modbus Outputs
                290mm (11.4")
                                                                                                          Optional:
364mm (14.3")
                                                                                                             Heater Interface Box
                                                                    Mounting Pipe
                                                                     (not supplied)                           Ease of connection for remote heated
                                                                                           127.5mm (5")
                                                                    30-58mm (1.2" - 2")                       wind sensors.
                                                                                                             Cables
                                                                                           74mm (3")
                                                        287mm (11.3")
                                                                                          Page 1 of 4
                                                                                           Technical Specifications
WIND MEASUREMENT                                                                     POWER SUPPLY
 Parameters            Wind speed & direction or U & V (Vectors)                         Input voltage           5 V to 30 V
 Units of measure      m/s, knots, mph, kph, ft/min                                      Current                 < 16mA (Output 1 second) @12 V
                                                                                         SDI-12
                       WIND SPEED               WIND DIRECTION                           Input voltage           12 V nominal (9.6-16 V)
 Range                 0-60m/s (134 mph)        0 to 359° - No dead band                 Current                 < 6.5mA Low power operation
 Accuracy              ±2% @12m/s               ±3° @12m/s
 Resolution            0.01m/s (0.02 mph)       1°                                   OUTPUTS
                                                                                         Digital outputs         RS232, RS422, RS485*,SDI-12 or Modbus
                                                                                                                 (user selectable)
AIR TEMPERATURE                                                                                                  * 2 wire point to point
                                                                                         Baud rates              4800-57600 (ASCII) or 1200 (SDI-12)
 Air temperature            Pt100 1/3 Class B
                                                                                         Protocols               ASCII, SDI-12 V 1.3, NMEA 0183,
 Range                      -50°C to +100°C
                                                                                                                 Modbus (RTU and ASCII)
 Accuracy                   ±0.1°C                                                       Data output             1s, 2s, 4s or polled mode
 Resolution                 0.1°C (0.1°F)
 Units of measure           °C or °F                                                 ENVIRONMENTAL
                                                                                         Protection class        IP65
RELATIVE HUMIDITY                                                                        EMC                     EN 61326
                                                                                         Operating temperature   -35°C to +70°C
 Range                      0-100% RH
                                                                                         Storage temperature     -40°C to +80°C
 Accuracy                   ±0.8% @ 23°C
                                                                                         Operating humidity      0% to 100% humidity
 Resolution                 0.1% RH
 Units of measure           % RH
                                                                                     MECHANICAL
 Compensated for temperature dependency
                                                                                         External construction   UV stabilised white thermoplastic
                                                                                         Fittings                Anodised Aluminium bracket to allow fitting to
                                                                                                                 30mm to 58mm mast dimensions
BAROMETRIC PRESSURE
                                                                                         Weight                  2.1kg (including bracket)
 Range                      600-1100hPa
 Accuracy                   ±0.5hPa
                                                                                     SOFTWARE
 Resolution                 0.1hPa
                                                                                         MetView                 Free software for the display of data
 Units of measure           hPa, mbar, mmHg, InHg                                                                and logging
 Compensated for temperature dependency -30°C to +70°C                                   MetSet                  Free software for the configuration of the
                                                                                                                 MetPak, MetPak RG & MetPak Pro
DEW POINT                                                                            OPTIONAL ACCESSORIES
 Resolution                 0.1°C (0.1°F)                                                Cables                  15m Power & Data cable
 Units of measure           °C or °F                                                                             USB Configuration cable
 Accuracy                   ±0.15°C (23°C ambient temp @ 20°C dew point)                 Hardware                Heater Interface Box
Specifications may be subject to change without prior notice.
MetPak integrates industry leading products in a convenient, economical package allowing
users to concentrate on the measurement rather than the quality of the measurement.
Calibration services available from Gill.
                                                                           Page 2 of 4
                                                                                     Wind Sensor Options
Base Station
MetPak is available as a Base Station which enables the system to be
specified with a remote wind sensor if required. This sensor can be
positioned away from the Base Station and a connection cable is provided.
The Base Station has been tested in accordance with BSEN 60945 and is
suitable for use in marine environments. This system can also be specified
without a wind sensor if wind measurement data is not required.
MetPak can be specified with a remote sensor from any of the options
shown below:
Wind Sensor Options
                                                                                        Wind speed and direction measurements to
                      For wind speed and direction measurements to
                                                                                        60 m/s with heating and impact resistant to
                      60 m/s. Corrosion free, polycarbonate housing.
                                                                                        UL2218 Class 1 & BSEN 60945.
                      With enhanced heating and wind measurements
                      up to 70 m/s for extreme conditions.
                      Three dimensional wind measurements up to 45 m/s                  Three dimensional wind measurement up
                      in a lightweight carbon fibre/aluminium construction.             to 65 m/s in a stainless steel housing.
Output rate from the wind sensors is controlled by the Base Station.
                                                                       Page 3 of 4
                                                                   Product Numbers Explained
Product options may be model specific. Consult the Gill sales team for availability
                                                                                                   1 = No Heating
                                              A = Base Station                                     2 = Standard Heating
       Product Code                           B = Integrated WindSonic                             3 = Enhanced Heating
          1723                      -        1           A        -               3                 -             2                11
                                        1 = MetPak                  1=    No Sensor Fitted                       Special Additional Features
                                        2 = MetPak Pro              2=    WindSonic                                 11 = Not Applicable
                                        3 = MetPak RG               3=    WindSonic M                               12 = ARG Rain Gauge
                                                                    4=    WindObserver 70
                                                                    5=    WindMaster
                                                                    6=    WindMaster Pro
Gill Instruments                                                                                                             www.gillinstruments.com
Saltmarsh Park, 67 Gosport Street                                                                                                               1723-0009 Iss 3
Lymington, Hampshire SO41 9EG                                                                                              Copyright © Gill Instruments 2015
United Kingdom
Tel: +44 (0) 1590 613 500
Fax: +44 (0) 1590 613 501                                                                                                    Gill Instruments Ltd, Reg No. 2281574
contact@gillinstruments.com                                               Registered Office: The George Business Centre, Christchurch Road, New Milton, BH25 6QJ