DC Power Systems
Feature Matrix for CE systems
Voltages 48 VDC 24, 48, 60* VDC 24, 48, 60* VDC 24, 48, 60* VDC
Max. Number of rectifiers 8 SMPS 200 2 Flatpack 1500 or 4 Flatpack 1500 6 Flatpack 1500
Flatpack 700
AC input 230 VAC 230/400 + N VAC 230/400 + N VAC 230/400 + N VAC
Approvals CE CE CE CE
Temperature rating -10oC to +55oC -40oC to +60oC -40oC to +60oC -40oC to +60oC
Typical applications
Point of Presence (POPs) Small UMTS & GSM Base UMTS & GSM Base UMTS & GSM Base
Digital Loop Carrier (DLC) Stations Stations Stations
Fiber Repeater Point of Presence (POPs) Point of Presence (POPs) Digital Loop Carrier (D
E911 (Public Safety) Digital Loop Carrier (DLC) Digital Loop Carrier (DLC) E911 (Public Safety)
Microwave Fiber Repeater Fiber Repeater Microwave
Digital Subscriber Line E911 (Public Safety) E911 (Public Safety) Digital Subscriber Li
(DSL) Microwave Microwave Co-location
Micro Cell Base Station Digital Subscriber Line Digital Subscriber Line Telephone Switches
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 4/72
7/24/2019 2004-05 Product Catalog Eltek
LARGE
rced convection Forced convection Forced convection Forced convection Forced convection
CU with Display/ RS- MCU with Display/ MCU with Display/ MCU with Display/ AEON Gold with Display/
2/ Ethernet/ RS-232/ Ethernet/ RS-232/ Ethernet/ RS-232/ Ethernet/ RS-232/ Ethernet/
odem/Web/SNMP Modem/Web/SNMP Modem/Web/SNMP Modem/Web/SNMP Modem
mp comp/ Volt/ Temp comp/ Volt/ Temp comp/ Volt/ Temp comp/ Volt/ Temp comp/ Volt/
rrent/ Capacity Current/ Capacity Current/ Capacity Current/ Capacity Current/ Capacity
rcuit breakers Circuit breakers/ Fuses Circuit breakers/ Fuses Circuit breakers/ Fuses Circuit breakers/ Fuses
MTS & GSM Base UMTS & GSM Base UMTS & GSM Base UMTS & GSM Base Telephone Switches
ations Stations Stations Stations Data Center
gital Loop Carrier (DLC) Digital Loop Carrier (DLC) Digital Loop Carrier (DLC) Digital Loop Carrier (DLC) Internet Hubs
11 (Public Safety) E911 (Public Safety) E911 (Public Safety) E911 (Public Safety) Optical Switches
crowave Telephone Switches Telephone Switches Telephone Switches Co-location
gital Subscriber Line Data Center Data Center Data Center Fixed Net Backbone Sites
-location Internet Hubs Internet Hubs Internet Hubs
ephone Switches Optical Switches Optical Switches Optical Switches
ternet Hubs Co-location Co-location Co-location
GSM Backbone Stations GSM Backbone Stations GSM Backbone Stations
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 5/72
7/24/2019 2004-05 Product Catalog Eltek
DC Power Systems
Feature Matrix for UL systems
Features DCD 125AP Flatpack system DCD 3FM-200A Flatpack system 400A Flatpack system
Approvals UL, CE, NEBS level 3 UL, CE, NEBS level 3 UL, CE, NEBS level 3
o o o o o o
Temperature rating -40 C to +70 C -40 C to +70 C -40 C to +70 C
Cooling Forced convection Forced convection Forced convection
System monitoring MCU with Display/ RS-232/ MCU with Display/RS-232/ MCU with Display/RS-232/
Ethernet/Modem/Web/SNMP Ethernet/Modem/Web/SNMP Ethernet/Modem/Web/SNMP
Battery monitor Temp comp/Volt/Current/ Temp comp/Volt/Current/ Temp comp/Volt/Current/
Capacity Capacity Capacity
DC distribution Circuit breaker and Fuses Up to 14 Circuit breakers or Up to 24 Circuit breakers or
Fuses Fuses
Typical applications
UMTS and GSM Base Stations UMTS and GSM Base Stations UMTS and GSM Base Station
Point of Presence (POPs) Point of Presence (POPs) Point of Presence (POPs)
Digital Loop Carrier (DLC) Digital Loop Carrier (DLC) Digital Loop Carrier (DLC)
Fiber Repeater Fiber Repeater Fiber Repeater
E911 (Public Safety) E911 (Public Safety) E911 (Public Safety)
Small Microwave Small Microwave Small Microwave
Digital Subscriber Line Digital Subscriber Line Digital Subscriber Line
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 6/72
7/24/2019 2004-05 Product Catalog Eltek
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 7/72
7/24/2019 2004-05 Product Catalog Eltek
DC Power systems
This section outlines the standard DC Power systems offered by Eltek. Our systems cover the entire
range of application areas within the telecommunications industry. A typical DC Power system includes
rectifiers, control and monitoring modules, AC distribution for rectifier input, DC distribution, batteries,
and low voltage disconnect options. All of our systems use state of the art "hot plug-in" switchmode
rectifiers for easily upgradable system power capability. Multiple rectifiers operate in parallel to ensure
redundant operation. For the purpose of this catalog Eltek’s systems are classified according to safety
agency recognition into CE-marked and UL-recognized. Furthermore the systems are classified into two
power ranges: small and medium, and large systems.
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 8/72
7/24/2019 2004-05 Product Catalog Eltek
Small and medium systems are designed for both stand-alone and DC POWER SYSTEMS
integrated solutions. The systems provide both convection (MPSU 200,
MPSU 4000, MPSU 5000, MPSU 6000) and forced air-cooling (Flatpack CE SYSTEMS ............................. 10
SMALL AND MEDIUM SYSTEMS
systems) regimes for all colocated equipment. Applications in either
WITH FORCED CONVECTION
indoor or outdoor cabinets are typically used to power equipment such as Flatpack MPSU 3000 .................... 11
POPs (Points of Presence), DLC (Digital Loop Carrier) cabinets, E911 Flatpack MPSU 6000 .................... 12
(Public Safety), 3G Wireless base stations, Fiber Repeaters, GSM/TDMA/- Flatpack MPSU 9000 .................... 13
CDMA wireless network base stations, Small Microwave Networks and Flatpack MPSU 12 kW .................. 14
Small Telephone Switches. Flatpack PRSB 9000 .................... 15
Flatpack PRSB 15 kW .................. 16
Flatpack PRSB 21 kW .................. 17
The Flatpack Power systems are Eltek’s latest development in the small Flatpack PRSB 30 kW .................. 18
and medium power range and represents the ultimate choice for compact, Flatpack Wallbox 3000 ................. 19
reliable, flexible and durable power systems at low cost. A typical Flatpack Power Tower .................. 20
Flatpack Power system contains Flatpack 1500 rectifiers, Power Racks
(PRs), a Monitoring and Control Unit (MCU) and a DC distribution system SMALL AND MEDIUM SYSTEMS
WITH NATURAL CONVECTION
of appropriate size and configuration. Multiple PRs may be combined and
MPSU 200 .................................. 21
paralleled to form power systems ranging from 1500 W to 60 kW. The MPSU 4000 ................................ 22
building block philosophy enables Eltek to tailor highly advanced power MPSU 5000 ................................ 23
systems according to customer requirements iin short timescale and at MPSU 6000 ................................ 24
low cost. Flatpack systems can be delivered as rack mountable units, or PRS 700 .................................... 25
in cabinets of different sizes with optional space for internal batteries. LARGE SYSTEMS
AEON 4000 ................................ 26
Large systems are designed for stand-alone solutions where high power
SVS system................................. 27
is required. These systems are typically used for Central Office Switches,
Internet Hubs, Web Hosting Sites, Optical Switches and Fixed Net Backbone DC DISTRIBUTION FOR CE SYSTEMS
Switches. AEON 4000 operates from 230 single phase VAC or 400 three PDU 19" MCB ............................. 29
phase VAC + N input. The High Current AEON 4000 also operates from a DCD 22 Way and 40 Way with LVBD 30
DCD 4000 system ....................... 31
208/480 VAC three phase input, for installations in the Americas.
PDU .......................................... 32
BDU .......................................... 33
All Eltek products and systems comply with international and local
standards. Our ambition is, however, to provide power solutions that offer UL SYSTEMS ............................. 34
more than just technical compliance. Our aim is to build products and SMALL AND MEDIUM SYSTEMS
DCD 125AP Flatpack system ......... 35
systems that are easy to install and maintain, with user-friendly software
and monitoring systems, simple maintenance procedures, and an attractive DCD 3FM-200A Flatpack system .... 36
400A/600A Flatpack system ......... 37
technical and visual design. We seek to build systems for the future that
Flatpack Cabinetized system ......... 38
comply with the strictest environmental requirements - anywhere in the TwinPack Plus® Power system ...... 39
world. Our success also means success for our customers.
LARGE SYSTEMS
AEON 4000 AM Single cabinet system 40
High Current AEON system ........... 41
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 9/72
7/24/2019 2004-05 Product Catalog Eltek
CE marking.
CE-marking is a European marking of conformity that indicates
that a product complies with the essential requirements of the
applicable European laws or Directives with respect to safety,
health, environment and consumer protection.
10
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 10/72
7/24/2019 2004-05 Product Catalog Eltek
derate the output power for self-protection. Flatpack MPSU 3000 is -- 482
482 xx 300
300 xx 89mm
178mm(2U)/19
(4U)/19xx11.8
11.8x x3.5"
7"
available in 24, 48, and 60 VDC configurations. • Weight: approx. excl. rectifiers
- 2U/5kg (11lbs)
- 4U/7kg (15.5lbs)
Typical applications
Rectifier
• Small UMTS and GSM Base Stations • Flatpack 700
• Point of Presence (POPs) • Flatpack 1500
• Digital Loop Carrier (DLC) Monitoring Unit
• Fiber Repeater • Flatpack MCU
• E911 (Public Safety) DC Distribution
• Microwave Flatpack MPSU 3000 2U, DC distribution in 1U
• Option 1:
• Digital Subscriber Line - 2 battery MCBs and 6 load MCBs
- Programmable LVD:
Standard/1 LVBD (max. 125 Amps)
Optional/1 LVLD (max. 125 Amps)
• Option 2*:
- 3 load MCBs, 1 load fuse and 1 battery fuse
Flatpack MPSU 3000 with 1U distribution - Programmable LVD:
Standard/1 LVBD (max. 125 Amps)
Optional/1 LVLD (max. 125 Amps)
Applicable standards
Flatpack MPSU 3000 with 3U distribution
• Safety: EN 60950, UL 60950
• EMC:
-- EN
ETSI61000-6-3
EN 300 386 V.1.3.1 (telecom.
(emission, network)
light industry)
- EN 61000-6-2 (immunity, industry)
• Environment:
- ETSI EN 300 019-2
- ETSI EN 300 132-2
Approvals
• CE-marked
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 11/72
7/24/2019 2004-05 Product Catalog Eltek
Applicable standards
• Safety: EN 60950, UL 60950
• EMC:
Flatpack MPSU 6000 with 3U distribution
-- EN
ETSI61000-6-3
EN 300 386 V.1.3.1 (telecom.
(emission, network)
light industry)
- EN 61000-6-2 (immunity, industry)
• Environment:
- ETSI EN 300 019-2
- ETSI EN 300 132-2
Approvals
• CE-marked
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 12/72
7/24/2019 2004-05 Product Catalog Eltek
Flatpack MPSU 9000 will operate in ambient temperatures up to +60°C • 482 x 300
Weight: x 267mm
approx. 15kg(6U)/19 x 11.8
(33lbs) excl. x 10.5"
rectifiers
(+140°F). At higher temperatures, each rectifier will derate the output
power for self-protection. Flatpack MPSU 9000 is available in 24, 48 and Rectifier
• Flatpack 700
60 VDC configurations. • Flatpack 1500
Monitoring Unit
Typical applications • Flatpack MCU
• UMTS and GSM Base Stations DC Distribution
• Digital Loop Carrier (DLC) • Up to 4 battery MCBs and 19 load MCBs
• Programmable LVD:
• E911 (Public Safety) - Standard/1 LVBD (max. 250 Amps)
• Microwave - Optional/1 LVLD (max. 250 Amps)
Approvals
• CE-marked
13
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 13/72
7/24/2019 2004-05 Product Catalog Eltek
Flatpack MPSU 12 kW
Approvals
Flatpack MPSU 12 kW • CE-marked
14
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 14/72
7/24/2019 2004-05 Product Catalog Eltek
battery size. The system accepts large variations in the input voltage and -- 600
600 x
x 600
600 x
x 630mm/23.6
900mm/23.6 x x 23.6
23.6 x
x 24.8"
35.4"
draws sinusoidal current with a soft start power-up. The Flatpack PRSB - 600 x 600 x 1800mm/23.6 x 23.6 x 70.9"
9000 will operate at full power in ambient temperatures up to +60°C • Weight: approx. excl. rectifiers
- 630mm/35kg (77lbs)
(+140°F). At higher temperatures, each rectifier will derate the output - 900mm/40kg (88lbs)
- 1800mm/70kg (154lbs)
power for self-protection. Flatpack PRSB 9000 is available in 24, 48 and
60 VDC configurations. Rectifier
• Flatpack 1500
Approvals
• CE-marked
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 15/72
7/24/2019 2004-05 Product Catalog Eltek
Flatpack PRSB 15 kW
Monitoring Unit
Typical applications • Flatpack MCU
Approvals
• CE-marked
Flatpack PRSB 15 kW
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 16/72
7/24/2019 2004-05 Product Catalog Eltek
Flatpack PRSB 21 kW
Monitoring Unit
Typical applications • Flatpack MCU
Approvals
• CE-marked
Flatpack PRSB 21 kW
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 17/72
7/24/2019 2004-05 Product Catalog Eltek
Flatpack PRSB 30 kW
modules and may be delivered in different indoor floor cabinets according -- 600
600 x
x 600
600 x
x 1500mm/23.6
1800mm/23.6 x x 23.6
23.6 x
x 59"
70.9"
to the required battery size (up to 400 Ah/48 VDC). - 600 x 600 x 2000mm/23.6 x 23.6 x 78.7"
- 600 x 600 x 2200mm/23.6 x 23.6 x 86.6"
• Weight: approx. excl. rectifiers
The system accepts large variations in the input voltage and draws sinuso- - 1.5m/88kg (194lbs)
- 1.8m/98kg (216lbs)
idal current with a soft start power-up. The Flatpack PRSB 30 kW will - 2.0m/105kg (231lbs)
operate in ambient temperatures up to +60°C (+140°F). At higher - 2.2m/110kg (242lbs)
temperatures, each rectifier will derate the output power for self-protection. Rectifier
Flatpack PRSB 30 kW is available in 24, 48 and 60 VDC configurations. • Flatpack 1500
Monitoring Unit
Typical applications • Flatpack MCU
Approvals
• CE-marked
Flatpack PRSB 30 kW
18
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 18/72
7/24/2019 2004-05 Product Catalog Eltek
Flatpack
Wallbox 3000
The Flatpack Wallbox 3000 will operate in ambient temperatures up to -- 8kg (17.6lbs)
12.5kg excl.
(27.5lbs) rectifiers
incl. rectifiers
+70°C (+158°F). At higher temperatures, the rectifier will derate the
Rectifier
output power and deliver the maximum possible power until it goes into • Flatpack 700
an over-temperature shutdown. • Flatpack 1500
Monitoring Unit
Wallbox FMA unit
Typical applications
• Local operation: Alarm reset
• Private Automatic Branch Exchange (PABX) • Alarm relays: 3 programmable outputs
• Visual indications:
• Digital Subscribe Line - Green LED – Power ON
• Micro Cell Base Stations - Red LED – Active alarm(s)
- LCD – system information
• Current measurement: Battery current
• Alarms:
- Load fuse alarm
- Module alarm
- Mains failure
- Battery fuse alarm
- High battery temperature (2 levels)
- Low battery temperature (2 levels)
- Low output voltage (2 levels)
- High output voltage (2 levels)
DC Distribution
• One battery MCB and up to 5 load MCBs
• Programmable LVD:
- 48 VDC/1 x 60 Amps
- 24 VDC/1 x 120 Amps
Applicable standards
• Safety: EN 60950
• EMC:
- ETSI EN 300
(telecom. 386 V.1.3.1
network)
- EN 61000-6-3 (emission, light industry)
- EN 61000-6-2 (immunity, industry)
• Environment:
- ETSI EN 300 019
- ETSI EN 300 132-2
Approvals
• CE-marked
19
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 19/72
7/24/2019 2004-05 Product Catalog Eltek
Flatpack
Power Tower
+60°C (+140°F). At higher temperatures, each rectifier will derate the Rectifier
• Flatpack 700
output power for self-protection. Flatpack Power Tower is available in 24, • Flatpack 1500
48 and 60 VDC configurations.
Monitoring Unit
• Flatpack MCU
DC Distribution options
Typical applications • Up to 15 load MCBs
• UMTS and GSM Base Stations • Up to 2 battery MCBs
• Programmable LVD:
• Digital Loop Carrier (DLC) - Standard/1 LVBD (max. 200 Amps)
- Optional/1 LVLD (max. 200 Amps)
• Fiber Repeater
• E911 (Public Safety) Applicable standards
• Safety: EN 60950, UL 60950
• Microwave • EMC:
• Digital Subscriber Line - ETSI EN 300 386 V.1.3.1
(telecom. network)
- EN 61000-6-3 (emission, light industry)
- EN 61000-6-2 (immunity, industry)
• Environment:
- ETSI EN 300 019-2
- ETSI EN 300 132-2
Approvals
• CE-marked
20
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 20/72
7/24/2019 2004-05 Product Catalog Eltek
MPSU 200
bution) SMPS 200 rectifier units. All distribution units allow input from • Weight:
rectifiersapprox. 8kg (17.6lbs) excl.
two separate battery banks via two 30 Amps MCBs. The AL 175NT alarm
unit controls the LVBD to prevent deep discharge of the batteries. Rectifier
• SMPS 200
Monitoring Unit
Typical applications
• AL 175NT
• Point of Presence (POPs)
Distribution
• Digital Loop Carrier (DLC) • Up to 6 load MCBs (2-40 Amps)
• Fiber Repeater • Up to 14 load fuses (glass) (5 or 10 Amps)
• E911 (Public Safety) Applicable standards
• Small Microwave • Safety: EN 60950, UL 60950
• EMC:
• Digital Subscriber Line - ETSI EN 300 386 V.1.3.1
(telecommunication network)
• Micro Cell Base Stations - EN 61000-6-3 (emission, light industry)
- EN 61000-6-2 (immunity, industry)
• Environment:
- ETSI EN 300 019-2
MPSU 200 with MCB distribution - ETSI EN 300 132-2
Approvals
• CE-marked
21
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 21/72
7/24/2019 2004-05 Product Catalog Eltek
MPSU 4000
telecommunications applications in the low power range. Rectifiers and Monitoring Unit
monitoring units are UL-recognized components. The Following options • AL 175NT
are possible: temperature probe for temperature compensated charging,
Distribution
load disconnect unit, battery disconnect unit, modem and external SNMP • Up to 10 load circuit breakers (2-50 Amps)
• One battery MCB (100 Amps)
agent. MPSU 4000 is available in 24, 48 and 60 VDC configurations. • LVBD unit controlled by timer or voltage
• LVLD unit controlled by timer or voltage
Typical applications Applicable standards
• Point of Presence (POPs) • Safety: EN 60950, UL 60950
• EMC:
• Digital Loop Carrier (DLC) - EN 61000-6-3 (emission)
• Fiber Repeater - EN 61000-6-2 (immunity, industry)
- EN 300 386-2 (immunity)
• E911 (Public Safety) • Network Rail Certificate of Acceptance
MPSU 4000
22
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 22/72
7/24/2019 2004-05 Product Catalog Eltek
MPSU 5000
range of monitoring and control features. The MPSU 5000 is available in • SMPS 1000
three different system voltages: 24 VDC/192 Amps, 48 VDC/105 Amps or Monitoring Unit
60 VDC/83 Amps. The DC distribution has one or two large load outputs, • AL 175NT
up to four additional small load outputs and a fused battery connection. It Distribution
• Option 1:
provides an ideal configuration for one or two Radio Base Station cabinets - 4 load MCBs (2-63 Amps)
that require a single DC feed. The Rectifiers and monitoring unit are UL- - 2 load MCBs (80 Amps)
- one battery MCB (250 Amps)
recognized components. The Following options are possible: temperature • Option 2:
probe for temperature compensated charging, battery disconnect unit, - 4 load MCBs (2-63 Amps)
- one load MCB (160 Amps)
modem and external SNMP agent. MPSU 5000 is available in 24, 48 and - one battery MCB (250 Amps)
60 VDC configurations. • LVBD controlled by timer or voltage
• Other distribution configurations may
be constructed upon request
MPSU 5000
23
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 23/72
7/24/2019 2004-05 Product Catalog Eltek
MPSU 6000
Distribution
The highly reliable and versatile AL 175NT provides a comprehensive range • Up to 16 load MCBs (2-63 Amps)
of monitoring and control features. Together with the flexible internal DC • Up to 2 NH00 (max. 160 Amps)
• LVBD controlled by timer or voltage
distribution, the MPSU 6000 can be tailored to meet most needs in • LVLD controlled by timer or voltage
telecommunications applications in the medium power range. The rectifiers • Other external distribution options are
available
and monitoring unit are UL-recognized components. The following options
Applicable standards
are possible: temperature probe for temperature compensated charging,
• Safety: EN 60950
load disconnect unit, battery disconnect unit, modem and external SNMP • EMC:
- EN 61000-6-3 (emission)
agent. MPSU 6000 is available in 24, 48 and 60 VDC configurations. - EN 61000-6-2 (immunity, industry)
- EN 300 386-2 (immunity)
• Environment:
Typical applications - ETSI EN 300 019-2
• Point of Presence (POPs) • Network Rail Certificate of Acceptance
MPSU 6000
24
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 24/72
7/24/2019 2004-05 Product Catalog Eltek
PRS 700
battery back-up. Internal battery back-up is dependent on the number of ETSI /21" x 23.62 x 70.87-86.61"
rectifier shelves. The system is equipped with the AL 175NT monitoring Rectifier
and control unit that offers a comprehensive range of monitoring and • SMPS 1000
control features. The rectifiers and the monitoring unit are UL-recognized Monitoring Unit
• AL 175NT
components. The following options are possible: external SNMP agent,
temperature probe for temperature compensated charging, load Distribution
• Option 1:
disconnect unit, battery disconnect unit and modem. - Up to 6 NH00 (160 Amps)
- Up to 27 load MCBs (2-50 Amps)
• Option 2:
Typical applications - Up to 2 NH2 (250 Amps)
• Point of Presence (POPs) - Up to 27 load MCBs (2-50 Amps)
• A wide range of customized distribution
• TETRA solutions, such as High Ohmic Distribution
and others that differ from our standard
• Cellular Base Stations configurations are available.
• Amplifier Sites
Applicable standards
• Safety: EN 60950
• EMC:
- EN 61000-6-3 (emission)
- EN 61000-6-2 (immunity, industry)
- EN 300 386-2 (immunity)
• Network Rail Certificate of Acceptance
Approvals
• CE-marked
PRS 700
25
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 25/72
7/24/2019 2004-05 Product Catalog Eltek
AEON 4000
Approvals
• CE-marked
• UL-recognition of SMPS 4000 and
AEON Gold
• NEBS Level 3 certified
AEON 4000
26
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 26/72
7/24/2019 2004-05 Product Catalog Eltek
SVS system
offers all the connections required for battery and load outlets as well as • Operating temperature:
(-14 to +113°F), -10 +60°C
full power to +45°C
(140°F)
enough space to integrate an optional LVD. with derating
• Storage temperature: -40 to +85°C
(-40 to +185°F)
The system comprises a Micro Processor Controller Unit, which is pro- • Dimensions (wxdxh):
- SVS 48/60V - 750/600A/
grammable with the integrated 3-button keyboard or with an external 600 x 600 x 2000mm/23.6 x 23.6 x 78.7"
laptop computer. All required interfaces, using volt free contacts, RS-232 - SVS 48/60V - 1250/1000A/
1400 x 600 x 2000mm/55.2 x 23.6 x 78.7"
and RS-485, are standard. For remote control purposes the power supply - SVS 48/60V - 2500/2000A/
can optionally be equipped with a modem (analogue, ISDN and GSM). It 2000 x 600 x 2000mm/78.7 x 23.6 x 78.7"
• Weight: fully equipped
is possible to apply remote control using our SNMP/ TCP/IP Ethernet - SVS 48/60V - 750/600A/
adapters. 315 kg (694.5lbs)
- SVS 48/60V - 1250/1000A/
519kg (1144.2lbs)
- SVS 48/60V - 2500/2000A/
A typical 2500 Amps System consists of two GRS 1250 power racks and 889kg (1959.9lbs)
one BVS 2500, two Battery Fuses (2 x 1250 Amps each) and enough
Rectifier
space for Power Outlets are available. The whole SVS system design is • RM 14400 Type: D60/200WBrug - 2 GRM
fully digital and highly modular. It is possible to build systems greater
Monitoring Unit
than 10 000 Amps as well as to extend existing systems under full load SVS-SM5/SVS-SP1
• Input voltage: 24 VDC/48 VDC/60 VDC
conditions if required. Several versions, such as the SVS 750 with an • Buttons for data request and adjustments
integrated DC distribution for medium power, are also available. • Display of measured values and error reports
• Communications interfaces: Internal
(controller)/ analog + RS 485, External
Typical applications (service laptop)/ RS 232
• Remote alarm: Modem, SNMP, TCP/IP
• DSL and SDH Networks • Event storage
• Characteristics: Float charging /Boost
• Telephone Switches charging
• Large Fiber Repeaters •• Load voltage compensation
Temperature regulation battery voltage
• Data Center and Internet Hubs • DC-Voltage/Current displays
• Optical Switches • Voltage monitors: Battery/Load:
Over voltage/Under voltage
• Battery discharge protection control
(Refer to pictures on the next page...) • Battery charging current limit
• Battery availability test (total battery)
• Battery balance monitoring
• System data: Serial number, rated voltage,
others
• LCD display/buttons
• Expandable by means of external signaling
modules
• Operating status signals: LED,
Telecommunications signals (urgent, not
urgent)
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 27/72
7/24/2019 2004-05 Product Catalog Eltek
SVS system: Refer to text on the previous page... Continues from previous page...
• Faults:
- System fault (centralized signal)
- Rectifier fault
- Redundancy monitoring
- Battery/Load voltage fault
- Battery availability test fault
- Battery unbalance
- Battery deep discharge
- Temperature fault
- Mains failure
- Voltage monitoring
- Fuse monitoring
- Signaling of site-based signal
(freely available): optionally expandable
• Potential free contacts:
- Fault
- Mains failure
- Boost charging characteristic
(ventilator control)
- Others: optionally expandable
DC Distribution options
• Standard configurations available up to
750 Amps/1250 Amps/2500 Amps capacity
respectively.
• Regional adaptations to local requirements are
available.
• Customized solutions can be engineered upon
request.
Power supply system
Approvals
• CE- marked
28
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 28/72
PDU 19" MCB
7/24/2019 2004-05 Product Catalog Eltek
distribution 24 way
29
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 29/72
7/24/2019 2004-05 Product Catalog Eltek
Approvals
• CE-marked
30
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 30/72
7/24/2019 2004-05 Product Catalog Eltek
The Master Control cubicle provides individual fused inputs for connecting 2 x 400
160 or 630
or 250 AmpsAmps Blade
Blade Fuse,
Fuse, 3 x 100,
1 x 240, 480,
rectifier cabinets and parallel connecting battery banks. The rating of the 600, 800, 1250 or 1600 Amps MCCB, 3 x 125
battery fusing can be fitted to match the standby requirements and will or 160 Amps MCCB
• Customer specific panels available upon
support autonomy periods from one to eight hours. This cubicle will also request
• Cable Management Bays fit adjacent to
contain the AEON Gold alarm module and will therefore provide a single Distribution cubicles
point for all control and monitoring functions.
General
• Dimensions per cubicle/bay (wxdxh):
Each Master Control Cubicle can connect to up to four distribution cabinets. 600 x 600 x 2000mm/23.62 x 23.62 x 78.74"
• Cable management cabinets may have half
Each distribution cabinet is built to accept up to eight plug-in distribution width (wxdxh):
units (PIDU). The customer can plug-and-play with the various PIDU 300 x 600 x 2000mm/11.81 x 23.62 x 78.74"
options therefore making installation and expansion flexible and easy. In Approvals
• CE-marked
a variety of applications the size and number of outgoing cables are large
due to voltage drop restraints. Installation and expansion is therefore
made easier by the deployment of adjacent cable management bays.
Low voltage disconnect is available through the use of Eltek’s Battery
Disconnect Unit (BDU), which aids installation and maintenance. These
distribution plants often support secondary distribution panels such as the
Eltek PDU. The overall system will support both under floor and overhead
cabling with top and bottom cable access. The systems can also be
configured to work in dual feed – “A” and “B” feed systems in accordance
with site-specific requirements.
Typical applications
• Telephone Switches
• Data Centers
• Internet Hubs
• Co-location
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 31/72
7/24/2019 2004-05 Product Catalog Eltek
PDU
General
The unit can also be configured to provide a single 1200 Amp, 80 Way • Dimensions (wxdxh):
600 x 600 x 2200mm/23.6 x 23.6 x 86.6"
distribution cabinet. • Weight: 125kg (275.6lbs)
Approvals
Typical applications • CE-marked
Facilitating a fully redundant “A” and “B” distribution system it fits into
applications where the power
quality is absolutely essential.
• Telephone Switches
• Data Centers
• Internet Hubs
• Co-location
PDU
32
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 32/72
7/24/2019 2004-05 Product Catalog Eltek
BDU
disconnection is required and a number of parallel battery strings are • disconnect the contactor
Alarm Outputs: The BDU for maintenance.
produces alarm
applied. Normally the BDU 1000 is mounted on the battery stand and signals for contractor tripped/failed and fuse
provides disconnection and isolation facilities for individual battery strings. fail that can be fed back via the AEON Gold.
• Indicators:
Up to twelve BDUs 1000 can work in parallel, controlled by the same - Green LED: BDU healthy and in operation
- Red LED: Contactor is open. Battery
AEON Gold unit. The BDU can be used with other power systems if disconnected
required. The unit is especially well suited on sites with high power and - Green and Red LED together: BDU in manual
override
long back-up times, requiring a number of large capacity battery strings
to be paralleled. This includes: General
• Dimensions (wxdxh):
• Co-location 450 x 250 x 600mm/17.7 x 9.7 x 23.6"
• Telecom Centers • Weight: 22kg (48.5lbs)
BDU
33
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 33/72
7/24/2019 2004-05 Product Catalog Eltek
This section of our catalog details various system solutions that have
been designed to incorporate UL related approvals at a system level
as well.
One of the most common safety agency listings, especially for systems
used within the United States, is Underwriters Laboratories Inc or
“UL”. Adherence to UL and other requirements are needed to
demonstrate regulatory and market requirements. If UL certification
is required for your application please select a solution from the
following pages. If your ideal system is not displayed in this section,
please contact your nearest Eltek representative so we can develop
a solution tailored to your specific needs.34
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 34/72
7/24/2019 2004-05 Product Catalog Eltek
DCD 125AP
Flatpack system
This compact system is ideally suited for small cabinetized applications Monitoring Unit
• Flatpack MCU
but can also be mounted into a standard relay rack or indoor cabinet.
This system is ideal for loads up to 6 kW. General
• Full system dimensions (wxdxh):
439 x 304 x 121mm/17.3 x 11.95 x 4.75"
Typical applications • Weight: max. 4.7kg (10.4lbs) excl. the MCU,
max. 5.4kg (11.9lbs) incl. the MCU
• UMTS and GSM Base Stations • Connections: rear
• Operating temperature: -40 to +70°C
• Point of Presence (POPs) (-40 to +158°F)
• Digital Loop Carrier (DLC)
Approvals
• Fiber Repeater • CE-marked
• E911 (Public Safety) • UL-recognized UL 1950
• NEBS Level 3 certified
• Small Microwave
• Digital Subscriber Line
35
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 35/72
7/24/2019 2004-05 Product Catalog Eltek
DCD 3FM-200A
Flatpack system
Rectifier
The DCD 3FM-200A has optional contactors for battery disconnect, load •• Flatpack
Flatpack 700
1500
disconnect and a combination of both for load shedding. It has two current
shunts to monitor battery and load current and a place to plug-in the Monitoring Unit
• Flatpack MCU
MCU controller for the Flatpack rectifiers. This compact system is ideally
General
suited for small cabinetized applications but can also be mounted into a • Full system dimensions (wxdxh):
standard relay rack or indoor cabinet. This system is ideal for loads up to 439 x 320 x 267mm/7.3 x 12.6 x 10.5"
• Weight: 21.7kg (48lbs)
9 kW. • Connections: front access
• Operating temperature: -40 to +70°C
(-40 to +158°F)
Typical applications
Approvals
• UMTS and GSM Base Stations
• CE-marked
• Point of Presence (POPs) • UL-recognized UL 1950
• NEBS Level 3 certified
• Digital Loop Carrier (DLC)
• Fiber Repeater
• E911 (Public Safety)
• Small Microwave
• Digital Subscriber Line
36
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 36/72
7/24/2019 2004-05 Product Catalog Eltek
400A/600A
Flatpack system
monitoring functions and a slot to plug in the MCU. A 2U MCU panel rated •• Weight: 74.84kg
Connections: rear(165lbs)
and front
for 600 Amps with all the above same attributes is also available.
Rectifier
• Flatpack 700
The 400A/600A has optional contactors for battery disconnect, load • Flatpack 1500
disconnect and both for load shedding. The system can be configured for Monitoring Unit
both battery and load breakers and accepts plug in fuses as well. If more • Flatpack MCU
distribution is required, another breaker panel can be easily added. DC Distribution options
• Up to 8 battery breakers
• Up to 24 load breakers
This compact system is ideally suited for small cabinetized applications • Optional LVBD
but can also be mounted into a standard relay rack or indoor cabinet. This • Optional LVLD
37
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 37/72
7/24/2019 2004-05 Product Catalog Eltek
Flatpack
Cabinetized system
contactors for battery and load, and many different battery distribution •• Flatpack
Flatpack 700
1500
options. The cabinets come in both non-seismic and seismic rated
(Telcordia GR-63-CORE Zone 4). Monitoring Unit
• Flatpack MCU
Distribution
Typical applications
• Up to 8 battery MCBs and up to 24 load MCBs
• Point of Presence (POPs) • Optional LVBD
• Optional LVLD
• Large Fiber Repeater
• Telephone Switches Approvals
• CE-marked
• Data Center • UL-recognized UL 60950
• Internet Hubs • NEBS Level 3 certified
• Optical Switches
• Co-location
• Cellular Base Station
• Fixed Net Backbone Sites
38
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 38/72
7/24/2019 2004-05 Product Catalog Eltek
TwinPack Plus®
Power system
39
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 39/72
7/24/2019 2004-05 Product Catalog Eltek
AEON 4000 AM
Single Cabinet system
power system, the SMPS 4000 rectifier modules are controlled and typical range 136kg (300lbs) to 227kg
(500lbs))
monitored by a microprocessor based controller called the AEON Gold. • Connections: Front
• Operating temperature: -10 to +50°C
(+14 to +131°F)
The AEON Gold monitoring unit can be accessed locally by a user-friendly
Rectifier
LCD screen and keypad. The AEON Gold can also be accessed via • SMPS 4000
WinPower, a Windows based software developed by Eltek Energy. Using
Monitoring
this interface makes the set up of AEON AM less complicated and much • AEON Gold
quicker. The AEON AM can also accommodate remote access communi-
Distribution
cation through SNMP or TCP/IP protocols. The AEON AM Power system • Up to 8 battery breakers
also offers versatile features such as: up to 72 plug-in breaker/fuse posi- • Up to 24 load breakers
• Optional LVBD
tions, large scale distribution or • Optional LVLD
Typical applications
• Point of Presence (POPs)
• Large Fiber Repeater
• Telephone Switches
• Data Center
• Internet Hubs
• Optical Switches
• Co-location
• Cellular base station
• Fixed Net Backbone Sites
AEON 4000 AM
40
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 40/72
7/24/2019 2004-05 Product Catalog Eltek
High Current
AEON systems
the system must be rated for the maximum current rating of the system. • Weight: depends
typical range on (500lbs)
227kg cabinet configuration,
to 317.5kg
This system provides the user the ultimate of flexibility on how the (750lbs) per cabinet
batteries and loads are connected into the DC Power system. • Connections: front
• Operating temperature: -10 to +50°C
(+14 to +131°F)
The distributive architecture is described as a system of many cabinets Rectifier
connected together. Each cabinet has rectifiers; primary load distribution • SMPS 4000
and battery load distribution collocated in each cabinet. Up to six cabinets Monitor
can be connected in series to provide more current for the user. The real • AEON Gold
benefit of this system is the smaller copper bus bars required. The largest Distribution
amperage connection required between cabinets is the maximum current • Primary Load and Battery Distribution
• Optional LVBD
of a single cabinet. A recent upgrade to AEON Gold software allows Eltek • Optional LVLD
• Secondary Load Distribution
to offer distributive architecture with SMPS 4000 rectifiers.
Approvals
• CE-marked
Typical applications • UL-recognition of SMPS 4000 and
• Point of Presence (POPs) AEON Gold
• NEBS Level 3 certified
• Large Fiber Repeater
• Telephone Switches
• Data Center
• Internet Hubs
• Optical Switches
• Co-location
• Cellular Base Station
41
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 41/72
7/24/2019 2004-05 Product Catalog Eltek
4U Plug-in PDU
a device is tripped. One set of Form C contact provides remote alarm • Dimensions
511 x 379 x (wxdxh):
160mm/20.1 x 14.9 x 6.3"
indication. The 23" mount unit provides 24 breakers and the 19" version • Weight: 13.5kg (29.75lbs)
provides 16 positions. Rear covers can be orders as an option.
Typical applications
• Telephone Switches
• Data Center
• Internet Hubs
• Co-location
4U Plug-in PDU
42
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 42/72
7/24/2019 2004-05 Product Catalog Eltek
144 Position
Plug-in PDU
breaker/fuse sections that can be separated into either two redundant • frame fromoption
Top cover the floor
feeds, four redundant feeds or six redundant feeds. Each input is rated for
650 Amps, and is designed for a maximum of an 800 Amps fuse/breaker Mechanical Information
• Dimensions (wxdxh):
feed. 610 x 610 x 2134mm/24 x 24 x 84"
• Weight:
- seismic cabinet fully loaded 219.5kg
Optional Digital Meter (484lbs)
- non-seismic cabinet fully loaded 199kg
An optional digital meter is available to measure current in each bus and (439lbs)
each breaker/fuse panel. The optional digital meter panels mounts on the
front door and has an LED display (xxx.x). It measures two bus currents
(“A” and “B”), main battery voltage and up to six branch currents Full scale
and zero offset adjustment potentiometers are provided and accessible
Typical applications
• Telephone Switches
• Data Center
• Internet Hubs
• Co-location
43
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 43/72
7/24/2019 2004-05 Product Catalog Eltek
GMT Fuse
distribution
panel ’s wide operating temperature range makes it suitable for most Approvals
indoor and outdoor environments. • UL-recognized UL 1801
• NEBS Level 3 certified
Typical applications
• Point of Presence (POPs)
• Digital Loop Carrier (DLC)
• Fiber Repeater
• E911 (Public Safety)
• Small Microwave
• Cellular base stations
• 3G
• Data Center
• Co-location
44
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 44/72
7/24/2019 2004-05 Product Catalog Eltek
45
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 45/72
7/24/2019 2004-05 Product Catalog Eltek
This section outlines the switchmode power supplies offered by Eltek. The rectifier will always be the
core component, the "heart" of a DC Power system. Eltek therefore devotes much of its R&D efforts to
the development of new state of the art designs, which have the quality and the functionality expected
in modern telecommunications business.
Eltek offers single phase rectifier modules with output power from 200 W to 4 kW and three phase
rectifier modules at 14.4 kW per module. All are hot plug-in units intended for parallel operation in a
DC Power system. Normally they serve as a combination of power supply and battery charger, but they
can also be utilized in applications where batteries are not present, supplying high quality DC power.
As a truly global company we seek to fulfill the most stringent requirements throughout the world
especially with regard to the input voltage range. Most rectifiers have active power factor correction
making the mains distortion minimal.
46
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 46/72
7/24/2019 2004-05 Product Catalog Eltek
For small and medium systems we offer following rectifiers: The SMPS RECTIFIERS AND CONVERTERS
200 is a 200 W convection cooled rectifier that operates at 230 VAC
input. Flatpack 700 is a fan-cooled rectifier providing 700 W power for Flatpack 700 and 1500 ................ 48
universal input voltage range. When more power is needed the SMPS Slimpack ................................... 50
SMPS 200 .................................. 51
1000, a 1000 W convection cooled rectifier that operates from a 230 VAC
SMPS 1000 ................................ 52
input, is an option. Eltek’s Flatpack 1500 compact rectifier provides TwinPack Plus® .......................... 53
complete flexibility by offering 1500 W output at 230 VAC. The TwinPack SMPS 4000 ................................ 54
Plus® rectifier is available in a 1500 W version for operation in 120 VAC RM 14400 .................................. 55
systems, and a 3000 W version for operation with 240 VAC input. Flatpack DC/DC converter ............ 56
For large systems the SMPS 4000, a 4000 W fan-cooled rectifier can be
utilized. All rectifiers have load-sharing features independent of any
monitoring and control unit. This optimizes an already long lifetime
(MTBF) expected for our rectifiers. We also have a three phase option in
the 14.4 kW module, RM 14400.
strive to design products that not only comply to high quality standards
and customer demands, but also represent the best in power supplies on
the market.
47
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 47/72
7/24/2019 2004-05 Product Catalog Eltek
Flatpack 700
and 1500
operation in a power rack system. Its very high power density, cost • max.factor:>
Power at 230 VAC
0.99 at 50% load or more
efficient design and ability to accept a wide input voltage range and tough • Input protection: Soft start, Surge protection
ambient conditions, makes it the perfect choice in any telecom network. (varistors), Internal fuses (L & N), Automatic
disconnect above 310 VAC
Output
Two Flatpack rectifiers can be plugged into a 1U high, 19" wide and • Voltage:
293mm (11.5") deep power shelf providing 1400 W (Flatpack 700), 2700 W - 24 VDC/range: 20-29.5 VDC
- 48 VDC/range: 44-59 VDC
(Flatpack 1500 24 VDC) or 3000 W (Flatpack 1500 48 VDC) DC power. - 60 VDC/range: 50-70 VDC
Multiple Power Racks may be combined and paralleled to achieve the • Output power:
- Flatpack 1500 24 VDC /1350 W
required amount of DC power. The Flatpack rectifier modules can also be - Flatpack 1500 48 VDC/1500 W
mounted vertically. When connected in parallel, the rectifiers provide - Flatpack 1500 60 VDC/1500 W
- Flatpack 700 48 VDC/700 W
active current sharing independent of the Monitoring and Control Unit. universal input
• Maximum current:
- Flatpack 1500 24 VDC/50 Amps at 27 VDC
Switchmode technology with soft switching and high switching frequency - Flatpack 1500 48 VDC/31.25 Amps at
48 VDC
is used to minimize volume and weight and to obtain fast output voltage - Flatpack 1500 60 VDC/25 Amps at 60 VDC
regulation. The module accepts large variations of the input voltage and - Flatpack 700 48 VDC/15 Amps at 48 VDC
• Hold up time: 20ms
draws sinusoidal current with a soft start power-up. • Efficiency:
- Flatpack 1500 24 VDC/> 88%
- Flatpack 1500 48 VDC/> 90%
Typical applications - Flatpack 1500 60 VDC/> 90%
- Flatpack 700 48 VDC/> 88% at 110 VAC,
The rectifier is used in Flatpack Power systems. > 90% at 230 VAC
General
(Refer to pictures on the next page...) • Rectifier alarm:
- Mains failure
- Module failure,
48
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 48/72
7/24/2019 2004-05 Product Catalog Eltek
Applicable standards
• Safety: EN 60950, UL 60950
• EMC:
- ETSI EN 300 386 V.1.3.1
(telecommunication network)
- EN 61000-6-3 (emission, light industry)
Flatpack 1500 24 VDC - EN 61000-6-2 (immunity, industry)
- Telcordia GR-1089-CORE
• Harmonics: EN 61000-3-2
• Environment:
- ETSI EN 300 019-2
- ETSI EN 300 132-2
- Telcordia GR-63-CORE Zone 4
Approvals
• CE-marked
• UL-recognized
• NEBS Level 3 certified
Flatpack 1500 48 VDC
49
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 49/72
7/24/2019 2004-05 Product Catalog Eltek
Slimpack
The controller card contains a mains sense circuit, battery contactor, •• Hold up time:90%
Efficiency:> 20ms
at full load
reverse battery polarity protection and battery current limit circuit.
Modern, yet well-proven technology makes the Slimpack a compact and General
• Rectifier alarms:
reliable power supply. In addition, a wide range of features are integrated. - Input voltage derating
- Temperature derating
- Over voltage shutdown
Typical applications - Current limit operation,
- Fan failure
The rectifier is used for all DC power requirements where a N+1 solution • Visual indications:
is not required, typically powering equipment such as: - Green LED: ON, no faults
- Red LEDs:
• Digital Subscriber Line Rectifier failure
Mains abnormal
Battery polarity reversed
LVBD disconnected
• Potentiometers:
- LVBD threshold
Slimpack - Float voltage
- Max. Battery Recharge current
- Equalize voltage
• Operating temperature: -40 to +70°C
(-40 to +158°F), no derating -40 to +55°C
(-40 to +131°F)
• Storage temperature: -40 to +85°C
(-40 to +185°F)
• Cooling: two fans (back to front airflow), brushless
w/ magnetic bearing
• Fan Speed: temperature regulated.
• MTBF:> 210 000 hours Telcordia Issue I,
method III (a)
• Acoustic Noise: < 60dBA at 100% fan speed
• I/O terminals: 0.08-2.5mm2/28-12 AWG
• Relay terminals: 0.14-0.5 mm2/26-20 AWG
• -Dimensions (wxhxd):
excl. brackets/
300 x 44.5 x 283mm/11.83 x 1.75 x 11.1"
- assembly/
482.5 x 44.5 x 283mm/19 x 1.75 x 11.1"
- ETSI assembly/
548 x 44.5 x 283mm/21.5 x 1.75 x 11.1"
• Weight: 3kg (6.6lbs)
Applicable standards
• Safety: EN 60950, UL 60950
• EMC:
- ETSI EN 300 386 V.1.3.1
(telecommunication network)
- EN 61000-6-3 (emission, light industry)
- EN 61000-6-2 (immunity, industry)
• Harmonics: EN 61000-3-2
• Environment: ETSI EN 300 019-2, ETSI EN 300 132-2
50 Approvals
• CE-marked
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 50/72
7/24/2019 2004-05 Product Catalog Eltek
SMPS 200
module accepts large variations in the input voltage and draws sinusoidal •• Hold-up time:
Efficiency: > 10ms
> 88%
current with a soft start power-up. When working in parallel, the rectifiers
provide active current sharing. General
• Volt free alarm: common output operated
under one of the following conditions
- Module failure,
Typical applications
- Low input voltage
The rectifier is used in the MPSU 200 Power Systems, typically powering - High output voltage shut down
• Visual indication: Green LED: Unit healthy
equipment such as: • Operating temperature: -10 to + 55°C
• Point of Presence (POPs) (+14 to +131°F)
• Storage temperature: -25 to +85°C
• Digital Loop Carrier (DLC) (-93 to +185°F)
• Fiber Repeater • Cooling: convection
• MTBF: > 700 000 hours
• E911 (Public Safety) • Dimensions (wxhxd):
35.5 x 128.4 (3U) x 220 mm/1.4 x 5 x 8.7"
• Small Microwave • Weight: < 1.5kg (< 3.3lbs)
• Digital Subscriber Line
Applicable standards
• Micro Cell Base Station • Safety: EN 60950
• EMC:
- EN 61000-6-3 (emission, light industry)
- ETS 300 386-2 (emission)
- EN 61000-6-2 (immunity, industry)
- ETS 300 386-2 (immunity)
• Harmonics: EN 61000-3-2
Approvals
• CE-mar ked
SMPS 200
51
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 51/72
7/24/2019 2004-05 Product Catalog Eltek
SMPS 1000
Output
• Voltage:
Switchmode technology with soft switching and high switching frequency - 24 VDC/11 VDC to 30 VDC adjustable,
internal over voltage protection: 30 VDC
is used to minimize volume and weight, and to obtain fast output voltage - 48 VDC/40 VDC to 58 VDC adjustable,
internal over voltage protection: 59.5 VDC
regulation. The module accepts large variations in the input voltage and - 60 VDC/Voltage: 50 VDC to 72 VDC adjustable,
draws sinusoidal current with a soft start power-up. For measuring the Internal over voltage protection: 73.5 VDC
• Max. current:
output current, LED indicators, voltage adjustment and test bushings are - 24 VDC/37 Amps (920 W +/-20 W at
26.8 VDC)
available on the rectifier’s front panel. - 48 VDC/21 Amps (1000 +/-20 W at 54 VDC)
- 60 VDC/16.7 Amps (1000 +/-20 W at 66.9 VDC)
• Hold-up time: > 10ms
Typical applications • Efficiency: > 91%
The rectifier is used in the MPSU 4000, 5000, 6000 and PRS 700 Power Operation
• Automatic over temperature derating for increased
systems, typically powering equipment such as: reliability
• Point of Presence (POPs) • Input for external shutdown signal
• Constant output power and current limitation for fast
• Digital Loop Carrier (DLC) battery recharge and safe operation
• Visual indications:
• Fiber Repeater - Green LED: Power ON/OFF
- Red LED: Module alarm
• E911 (Public Safety) •
- Yellow LED: Current limit operation
Rectifier alarm output, activated by internal failure
• Small Microwave • Plug-in connection facilitating easy service and
• Cellular base stations maintenance without load interruption
• Power factor corrected input providing reduced
• 3G harmonics and minimal input power requirements
• MTBF: 433,944 Bellcore IIIb, +25°C (77°F)
• TETRA • Cooling: convection
• Amplifier Sites • Operating temperature: -10 to +70°C (+14 to
+158°F), output power derating occurs at approx.
+40°C (+104°F) depending on the airflow inside the
cabinet
• The SMPS 1000 supports the following control functions:
- Remote output voltage adjust for temperature
compensation, boost charging and battery testing
- Active current sharing for increased reliability in
parallel operation
- Comprehensive alarm and control facilities for
remote and local monitoring
General
• Dimensions (wxhxd):
- 66.8 (6U) x 264 x 220 (excl. handle)/
2.63 x 10.4 x 8.66"
- 66.8 (6U) x 264 x 240mm (incl. handle)/
2.63 x 10.4 x 9.45"
• Weight: < 2.8kg (< 6.2lbs)
Applicable standards
• Safety: EN 60950
• EMC:
- EN 61000-6-3 (emission)
- EN 61000-6-2 (immunity, industry)
- EN 300 386-2 (immunity)
SMPS 1000
• Environment:
- ETSI EN 300 019-2-1
- ETS 300 019-2-2
- ETS 300 019-2-3
Approvals
52 • CE-marked
• UL- Recognized UL 60950
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 52/72
7/24/2019 2004-05 Product Catalog Eltek
TwinPack Plus®
Approvals
• CE-marked
TwinPack Plus® • UL-recognized UL 60950
53 • NEBS Level 3 certified
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 53/72
7/24/2019 2004-05 Product Catalog Eltek
SMPS 4000
represents a high quality power source for critical telecom equipment Output
• Output power
where the power demand can go all the way up to 384 kW. - 48 VDC/4000 W, constant power down
to 48
- 60 VDC, maximum
VDC/4000 current
W, constant 85 down
power Amps
Typical applications to 60 VDC, maximum current 70 Amps
The rectifier is used in the AEON 4000 Power System, typically powering - 24 VDC/3350W, maximum current
125 Amps
equipment such as: • Efficiency: > 91%
• Telephone Switches Operation
• Data Center • Connections: rear, hot swappable
• Output Fuse: 160 Amps
• Internet Hubs • Active Current Sharing Accuracy: +/- 2.5%
• Optical Switches of nominal current
• Cooling: fan assisted (3 redundant fans)
• Co-location • Communication interface:
• Fixed Net Backbone Sites - Customized LCD display and keypad
- CAN-bus for rectifier and control unit
communication
• Available information:
- Input Voltage, Output Voltage
- Output Current
- Internal Temperature
- Power limit
- Address
- Software version
• Available alarms:
- Low Mains
- High Mains
- High Temperature
- Output Fuse
- Output High Voltage Shutdown
- Internal Failure
- Communication Error
General
• Dimensions (wxhxd):
• 80 x 2647.5kg
Weight: x 450mm/3.2
(16.5lbs) x 10.4 x 17.7"
Approvals
• CE-marked
• UL-recognized UL 60950
• NEBS Level 3 certified
SMPS 4000
54
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 54/72
7/24/2019 2004-05 Product Catalog Eltek
RM 14400
Large power plants with output currents of more than 10 000 Amps can Output
• Voltage: 24 VDC/48 VDC/60 VDC
easily be realized. (range: 22.2-73.5 VDC)
•• Output power:250
Max. current: 14.4Amps
kW
Our standard product range offers several power supply systems from
between 750 Amps and 2500 Amps. Other sizes can be customized and General
• Efficiency: > 93%
designed upon request. The highly modular system allows great flexibility, • Rectifier Alarm: Different alarms on LCD,
Mains fault and rectifier fault on volt free
with outstanding performance and powerful remote monitoring capabilities contacts
such as modem, SNMP, TCP/IP solutions. • Visual indications: LCD display, LED for
operation, LED for fault
• Operating temperature:
The basic RM14400 rectifier operates in three phase 400 VAC mains with- -10 to + 45°C full power
(+14 to +113°F), +60°C with derating
out neutral. The input voltage ranges from 184/320 VAC to 264/457 VAC. (+140°F)
• Storage temperature: -40 to +85°C (-40 to
+185°F)
Typical applications • Cooling: forced cooling
• MTBF: > 250 000 hours
The RM 14400 is used in SVS Power systems, typically powering • Acoustic Noise: < 55dBA
equipment such as: • Dimensions (wxdxh):
483 x 440 x 272mm (6U)/19 x 17.3 x 10.7"
• DSL and SDH Networks • Weight: 43.5kg (100lbs)
• Telephone Switches
Applicable standards
• Large Fibre Repeaters • Safety: EN 60950, class 1
• EMC:
• Data Centre and Internet Hubs - EN 61000-6-3 (emission)
• Optical Switches (EN 55022, class B)
- EN 61000-6-2 (immunity)
• Environment:
- ETSI EN 300 019-2
- ETSI EN 300 132-2
• Protection class: IP20, EN 60529
RM 14400
Approvals
• CE-marked
55
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 55/72
7/24/2019 2004-05 Product Catalog Eltek
Flatpack DC/DC
converter
Applicable standards
• Safety: EN 60950, UL 60950
• EMC:
- EN 300 386 (telecommunication network)
- EN 61000-6-3 (emission, light industry)
- EN 61000-6-2 (immunity, industry)
• Environment:
- ETSI EN 300 019-2
- ETSI EN 300 132-2
- Telcordia GR-63-CORE Zone 4
- ETSI EN 300 753 (acoustic noise)
Approvals
• CE-marked
• UL-recognized
• NEBS Level 3 certified
56
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 56/72
7/24/2019 2004-05 Product Catalog Eltek
57
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 57/72
7/24/2019 2004-05 Product Catalog Eltek
System monitors
This section outlines our standard monitoring and control units. The products in this range include:
integrated system health monitoring solutions, stand-alone monitoring devices, monitoring of DC power
supplies and distribution and battery support.
Eltek is committed to achieving and maintaining technological excellence of not only our DC Power and
Distribution products, but also our Monitoring and Control solutions. We are able to offer monitoring
products that are easily integrated into an existing telecommunications network infrastructure using
proven, inter-operable, stable and secure technologies and globally accepted communications protocols.
These products provide real-time feedback of critical system parameters and alarm events. This data can
be applied toward statistical analysis of preventive maintenance schedules. Increased DC Power system
reliability is a direct result of this enhanced intelligence.
58
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 58/72
7/24/2019 2004-05 Product Catalog Eltek
For small and medium systems we offer the AL 175NT and Flatpack SYSTEM MONITORS
MCU product lines. These monitoring and control units provide visual
display of system and battery parameters and remote capability with a SMALL AND MEDIUM
serial/modem connection. Using Eltek’s WinPower software, a user can Flatpack MCU ............................. 60
TWPP/MCU panel ........................ 61
connect directly to the power plant with a PC for graphical user interface
AL 175NT ................................... 62
support. If needed, an SNMP device can be connected to the AL 175NT or
Flatpack MCU alarm modules to provide an Ethernet connection with the LARGE
SNMP agent capability. AEON Gold ................................. 63
For large systems we offer the AEON Gold that provides a graphical SOFTWARE
WinPower ................................... 64
display of system and battery parameters and remote capability over a
serial or modem connection. The sophisticated WinPower solution is also
REMOTE MANAGEMENT
available with the AEON Gold, with extensive battery monitoring and
SNMP adapter ............................. 65
testing capabilities. An SNMP agent option is also available for the AEON WebPower .................................. 66
Gold.
59
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 59/72
7/24/2019 2004-05 Product Catalog Eltek
Flatpack MCU
• (local
Menu operation)
driven operation via WinPower Silver
Typical applications • Battery monitoring and testing without site
The Flatpack MCU is used in the Flatpack Power systems. attendance (history up to 10 previous tests)
• Advanced or simple battery test
• Temperature Compensated Charge Voltage for
increased battery lifetime
• Hot Plug-in MCU unit
• Slow current walk-in
• Password protected access levels
Flatpack MCU
• Alarm/event log with time and date
(up to 255 events)
• Site text/ID for identification of each
individual system
• Output Voltage Measurement
• Load Current Measurement
• Battery Current Measurement
• Rectifier Current Measurement
• Battery Temperature Measurement
• Load/Battery Disconnect
• Real Time Clock
• Battery Boost Charging
• Battery Cable Voltage Drop Compensation
Alarms
• Battery High/ Low Voltage (multi level)
• Battery/ load fuse
• Symmetry alarm
• Rectifier Fail Alarm (critical and non critical)
• Temperature Compensated Charging
• Low temperature
• Rectifier capacity with programmable level
• Low temperature with programmable level
• Temperature probe
• Battery discharge
General
• System voltage: 24 VDC/48 VDC/60 VDC
• Dimensions (wxhxd):
123 x 43 x 177mm/4.85 x 1.7 x 6.97"
• Weight: 0.7kg (1.55lbs)
Applicable standards
• EMC and Safety: EN 300 386-2 and
EN 60950
• ETSI EN 300 019-2 (environmental tests for
transportation, storage and operation)
Approvals
• CE-marked
• UL-recognized UL 60950
• NEBS Level 3 certified
60
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 60/72
7/24/2019 2004-05 Product Catalog Eltek
TWPP/MCU panel
and industrial applications. TWPP rectifier output voltage is under MCU • system
Remote via front keypads
monitoring via theand LCD
front access RS-232
control and does not require periodic re-adjustment. Individual rectifier serial interface.
adjustments are no longer necessary. • Direct serial connection, modem or WebPower/
SNMP agent is supported.
General
The MCU controller is hot swappable in a live system without affecting the • Dimensions: single 44mm (1.75") mounting
system’s ability to deliver charge and load current. Intelligent LVD contactor height (1U)
• Mounting brackets available for 482mm (19")
drive circuitry prevents spurious operation of the LVD contactor(s) in the and 584mm (23") rack mounting
system upon system controller failure or removal. Integrated temperature • Weight: 1kg (2.1lbs)
• Operating temperature: -40 to +70°C
compensated charge control and battery symmetry monitoring serve to (-40 to +158°F)
maximize battery life and protect against battery damage.
TWPP/MCU panel
61
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 61/72
7/24/2019 2004-05 Product Catalog Eltek
AL 175NT
cable, modems or SNMP agent. • Battery monitoring and testing without site
attendance
• Temperature compensated charging for
Remote monitoring options increased battery lifetime.
• Hot plug-in
• With the Windows-based WinPower communication program installed • Password protected access levels
• Alarm/event log with time and date
on a remote computer, the system can be monitored and controlled via (up to 255 events)
modems. WinPower provides a user-friendly interface (GUI) for remote • Site text/ID for identification of each
individual system
control and supervision. The modem callback functionality can be used • Controls LVD units based on voltage or internal
to minimize the traffic on the public telephone network. timer
• High/Low Battery Voltage Alarm
• From a Network Management System (NMS) via Ethernet. Simple • Battery boost charging
Network Management Protocol (SNMP) with an external SNMP agent • Load/Battery Disconnect Alarm
Approvals
• CE-marked
• UL-recognized UL 60950
AL 175NT
62
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 62/72
7/24/2019 2004-05 Product Catalog Eltek
The RS-232 serial interface provides connectivity for remote monitoring, •• Eight digital
Flexible alarminputs
system setup
either via serial cable, modems or SNMP agent. The unit incorporates • Temperature Compensated Charging
highly advanced functionality, which makes it the preferred choice in • Boost Charging
• Battery Test with capacity calculation
applications where high reliability and demanding control functions are • Individual Rectifier Control
required. General
• AC input voltage: 100-300 VAC
• DC supply voltage: 20-60 VDC
Typical applications • Maximum alarm relay current: 8 Amps
The AEON Gold unit is used in the AEON 4000 and High Current AEON • Dimensions (wxhxd):
- Display unit/
Systems. 490 x 89 x 33mm/19.3 x 3.5 x 1.3"
- Controller unit/
557 x 128 x 103mm/21.9 x 5.04 x 4.1"
• Weight: 2.4kg (5.3lbs)
Applicable standards
AEON Gold display unit • CE-marked
• UL-recognized
• NEBS Level 3 certified
63
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 63/72
7/24/2019 2004-05 Product Catalog Eltek
WinPower
ments to applications where the power requirement is up to approximately but nothing can be changed.
60 kW. WinPower Silver can be used with Eltek products like MPSU 200, The next level, service level, requires a password.
MPSU 4000, MPSU 5000, MPSU 6000, PRS 700 and the Flatpack systems Here it is possible to change the system settings
and turn the system on and off.
range.
The third level, factory menu, is normally
programmed during factory test and contains basic
WinPower Gold covers the high power requirements and goes along with parameters like system voltage and contactor
configuration.
the AEON 4000 Power Systems. Sites with several hundreds of kW can be
monitored and controlled using WinPower Gold. WinPower can be used on a remote computer with
e.g. modem connection to the site. In addition to
remote access to all functions in the system it is
also possible to get automatic callback on alarms.
64
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 64/72
7/24/2019 2004-05 Product Catalog Eltek
SNMP Adapter
65
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 65/72
7/24/2019 2004-05 Product Catalog Eltek
WebPower
• Locations requiring connectivity to a centralized SNMP Network • Real-time Data Feedback of critical
Management Station system parameters and alarm events can
• Mission-critical power systems requiring real time data access from be achieved from virtually anywhere on the
planet.
diverse locations
• Remote Control of the DC Power system
enables power system administrators to
perform advanced troubleshooting methods -
and avoid disastrous system downtime.
66
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 66/72
7/24/2019 2004-05 Product Catalog Eltek
67
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 67/72
7/24/2019 2004-05 Product Catalog Eltek
Outdoor cabinet
solutions
68
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 68/72
7/24/2019 2004-05 Product Catalog Eltek
Remote powering
of broadband/ DSL
or ±130 VDC from a 48 VDC source for remote powering of telecom - 48/190 VDC with a total of 432 output
36 VA-limiters
equipment. The power system consists of DC/DC converters, VA limiters channels
providing a safe distribution of the power over existing twisted pairs, and - Dimensions (wxdxh):
600 x 600 x 2000mm/24 x 24 x 79"
a remote end DC/DC converter converting the high DC voltage down to 48 - Weight: 300 kg (661.4lbs) excl. converters
and VA limiters
VDC for powering the DSLAM equipment. The Flatpack VA limiter unit is
designed to protect the Remote Feeding Telecommunications Circuits Modules
• DC/DC converter
(RFT) from overvoltage, overcurrent and leakage current to ground, and - Input: 48 VDC (40-60 VDC)
the design is based on the IEC 60950-21, IEC 60950 and GR-1089-CORE - Output:
130 VDC: (125-139 VDC)/6.6 Amps
safety standards. 90 VDC: (160-199 VDC)/6.6 Amps
- Dimensions (wxhxd):
218 x 43 x 240mm/8.58 x 1.69 x 9.45"
The VA limiter is designed for ±190 VDC and ±130 VDC system voltage, - Weight: 3kg (6.6lbs)
• VA Limiter
RFT-V and RFT-C circuits. The module has 12 outputs of up to 100 W - Input: ±130 VDC or ±190 VDC
each (RFT-V). The central office systems vary from 2U/ 24 outputs to - Output:
12 channels of ±130 VDC or ±190 VDC
complete cabinets with up to 432 VA limiter outputs. The remote end RFT-V: max. 100 W
converter consist of parallel DC/DC converters specifically designed to RFT-C: max. 50mA
- Dimensions (wxhxd):
work from a limited power source (VA limiter) fed over a high impedance 214 x 41.5 x 243mm/8.4 x 1.6 x 9.6"
- Weight: 1.5kg (3.3lbs)
line and incorporates high energy surge protection. The modules can be
paralleled to meet the power requirement Remote End Converter
• Input: 100-400 VDC, 2 to 10 channels per
at the remote end. module
• Output: 54 VDC (48-55 VDC)/1.5 Amp per
channel
Typical applications
Approvals
Operators can introduce personalized • EN 60950 (pending)
multimedia services such as •• EN 60950
UL 60950-21 (pending)
(pending)
• Video On Demand • Telcordia NEBS GR-63-CORE (pending)
• Interactive Gaming • Telcordia NEBS GR-1089-CORE (pending)
• Video Conferencing
• Real-time Broadcast TV
• Internet
Mini RPS
Base COPS
69
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 69/72
7/24/2019 2004-05 Product Catalog Eltek
Extensive service
offer
Preventive Maintenance
A regular check on your equipment often prevents expensive repairs by
identifying any default or weakness as early as possible. A full report
follows each visit. This gives you an update on the condition of your
equipment and helps you plan upgrading, expansion or renewal. Our Our dedicated team of engineers
standard preventive maintenance service includes full test, visual check, and officially certified partners can
real and simulated alarm checks, alarm history check and a full report perform a wide range of services on
with recommendations. our products: 24 hours a day, 7 days
a week.
Battery maintenance
In addition to system maintenance, Eltek is able to perform battery
maintenance. This includes supplying all of the measuring tools and load
equipment necessary to operate a controlled discharge of the battery
bank and test each individual cell. All measurements are recorded and
listed in a report presented at the end of the operation.
On site service
On site service is available both as part of a service contract and on an
Product repairs
All product repairs are based on fixed prices and are guaranteed for one year.
Training
A comprehensive range of training courses is available and can be
customized to meet specific customer needs.
70
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 70/72
7/24/2019 2004-05 Product Catalog Eltek
Abbreviations
3G – Third generation mobile cellular networks MPSU – Modular Power Supply Unit
AC – Alternating Current ms – Abbreviation for millisecond
AM – Product configured for requirements of MTBF – Mean Time Between Failure
North and South America NEBS – Network Equipment-Building Systems
Ah – Abbreviation for ampere-hours NMS – Network Management System
Amp – Abbreviation for ampere PABX – Private Automatic Branch Exchange
Arms – Abbreviation for ampere root mean square PC – Personal Computer
AWG – American Wire Gauge pComm – Binary master-slave communication
BDU – Battery Distribution Unit protocol
CDMA – Code Division Multiple Access PDA – Personal Digital Assistant
CE – European mark of conformity PDU –
Power Distribution Unit
COPS – Central Office Power Supply PIDU –
Plug-in Distribution Units
DC – Direct current POPs –
Points of Presence
DCD – DC Distribution PR –
Power Rack
DLC – Digital Loop Carrier PRS –
Power Rack System
DSL – Digital Subscriber Line PRSB –
Power Rack System with Battery
DSLAM – Digital Subscriber Line Access Multiplexer RC –
Remote Control
EMC – Electromagnetic Compatibility RFT-V/-C –
Remote Feeding Telecommunications
EN – European Norm Circuits
ETSI – European Telecommunications RM – Rectifier Module
Standards Institute RPS – Remote Powering System
EPO – Emergency Power Off SDH – Synchronous Digital Hierarchy
FMA – Flatpack Monitoring Alarm module SMPS – Switch Mode Power Supply
Form C – A relay contact set description consisting SMS – Short Message Service
of a make, break and a common connection SNMP – Simple Network Management Protocol
GSM – Global Standard for Mobile Communications SSD – System Status Display
GUI – Graphical User Interface TCO – Total Cost of Ownership
HTML – Hyper Text Markup Language TCP/IP – Transmission Control protocol/
HTTP – Hyper Text Transfer Protocol Internet Protocol
I/O – Input/ Output TDMA – Time Division Multiple Access
IEC – International Electrotechical Commission TETRA – Terrestrial Trunked Radio
IP – Internet Protocol THD – Total Harmonic Distortion
ISDN – Integrated Services Digital Network TWPP – TwinPack Plus® power system
LAN – Local Area Network TWPP/MCU – Monitoring and Control Unit in
LCD – Liquid Crystal Display TwinPack Plus® power system
LED – Light Emission Diode U – Height unit (44.45mm (1.75"))
LVBD – Low Voltage Battery Disconnect UL – Underwriters Laboratories Incorporated
LVD – Low Voltage Disconnect UMTS – Universal Mobile Telecommunications
LVLD – Low Voltage Load Disconnect System
MCB – Miniature Circuit Breaker VA – Abbreviation for volt-ampere
MCCB – Molded Case Circuit Breaker VAC – Abbreviation for alternating current
MCU – Monitoring and Control Unit VDC – Abbreviation for direct current
MIB – Management Information Base W – Abbreviation for watt
71
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 71/72
7/24/2019 2004-05 Product Catalog Eltek
HEAD OFFICE
Eltek Energy AS
PO Box 2340 Strømsø, 3003 Drammen
Gråterudveien 8, 3036 Drammen
Norway
Tel: +47 32203200
Fax: +47 32203210
www.eltekenergy.com
http://slidepdf.com/reader/full/2004-05-product-catalog-eltek 72/72