Warranty
1+1  *
                                                                                                      years
     Ameza
     Ceiling fan
     INSTRUCTION MANUAL
ATOMBERG TECHNOLOGIES PVT LTD
Registered office : Atomberg Technologies Pvt Ltd, 3rd Floor, Tower B, 247 Embassy Park, LBS Marg,
Vikhroli West, Mumbai, Maharashtra, India, Pin Code - 400083
Manufacturing unit : Atomberg Technologies Private Limited, Mind Space Shelters LLP / Vithai
Developers LLP Gat No. 51-59; Bhamboli, Chakan, Pune, Maharashtra, India, Pin Code - 410507
For an additional 1 year extension, kindly register the warranty.
*
PACKAGE CONTENTS                                                        TOOLS NEEDED
                                                                               Pliers
                                                                               Screw driver
       Motor                    3 Blades                  Shackle kit
                                                                               Tester for
                                                                               wire connection
                                                                               Open end spanners
      Downrod      2 Canopies              Canopy plate    Remote
                                                              +
                                                          2 Batteries          Step ladder
To avoid risk of fire, shock & injury -
- Only use the product as intended by Atomberg
- The wiring of the fan must be done by a qualified person or trained electrician
- For any product related queries, please contact Atomberg
What makes Atomberg ceiling fans best in class?
•   Energy-efficient BLDC motor that saves up to 65% energy
•   Runs 3x longer on inverter leading to longer inverter runtime
•   Less heating of fan even after long hours of runtime, resulting in longevity
•   Consistent speed even at low voltages
•   Universal remote - without pairing for easy speed controls
•   Double ball bearing for higher reliability
•   Moisture resistant protective coating on PCB
•   Every fan is tested for durability in extreme Indian conditions
     SAFETY INSTRUCTIONS
Please read carefully before assembling and installing the fan to avoid any risk of
injury or damage to the product.
1.    Do not install the fan if any part is damaged or missing.
2.    Only use Atomberg-approved parts or accessories supplied with this product and/or
      any accessories designed specifically for this product by Atomberg. Any such use of
      other parts or accessories may turn the product warranty null and void, and may
      result in personal injury or property damage.
3.    Not recommended for use in high-humid areas with direct or indirect exposure to
      water entries.
4.    Installation warnings:
      - Secure blades properly with screws and washer to avoid injury during operation.
        An imbalanced fan may damage the motor and reduce the lifetime of the fan.
      - Damage from incorrect installation or improper practices are not covered under the
        warranty terms. Please check the warranty terms in detail.
      - Do not turn on the fan until the blades are securely fastened to the ceiling fan.
      - Any connection to wires must be securely sealed using electrical insulation tape to
        prevent electric shock or fire hazard.
      - Avoid pinching wires between the shackle kit, down rod and ceiling hook to prevent
        electric shock or fire hazard.
5.    Bypassing regulator:
      - Eliminate regulator by using a direct connection from the switch to the fan and
        do not use the regulator as the fan is operated using a remote.
      - Not bypassing the regulator may lead to speed variations, restarting, low speed or
      product damage.
6.    Additional:
      - Be careful while cleaning the fan or painting/working near the fan. Always turn off
        the power to the ceiling fan before servicing or cleaning.
      - Do not put your hand or any other objects near the fan blades while the fan is
        running.
      - Do not modify the blade design to change the air flow.
      - Children should be supervised to not play with the appliance.
      - This appliance is not for use by persons (including children) with reduced physical,
        sensory, or mental abilities, or lack of experience, unless supervised by someone
        responsible for their safety.
      - Dispose off electrical parts at designated collection facilities. Contact local
        authorities for disposal options. Avoid landfills to protect the environment.
Please note:
      In case of remote model:
1.    The fan will not function if the input voltage is more than 285V.
2.    The fan will not function with square type inverter if the voltage is more than 285V and
      400V peak.
      In case of regulator model:
1.    The fan will not function if the input voltage is more than 285V.
2.    The fan will not function with square type inverter if the voltage is above 285V and 400V
      peak.
3.    For a better performance use step regulator as the fan will not operate at a lower range if
      used with a non-compatible stepless (triac based) regulator.
   INSTALLATION
Please follow all steps to ensure efficient performance
01
                                                                Mandatory Step
                                 Shackle kit
                                                                Bypass the regulator before installing your
                                 Top canopy
                                                                Atomberg fan for optimal performance.
                                 Downrod                        Refer to the image for the correct order of
                                                                parts. Carefully remove the motor from the
         Blade                   Bottom canopy
                                                                box and place it on soft padding to avoid
                                                                scratches.
                                 Shaft with motor
                                                                                                           IF 'H' >240mm
02
                                                                                                       1
                                              1                 2
                                                                                                           Fit the down rod, glide the
                                                                                                           top canopy on it and fit
                                                                             CANOPY PLATE                  the bottom canopy.
                                                                             DOWNROD
                            'H'
                                                                                                           IF 'H' <240mm
                    DOWNROD BELOW CEILING
                                                                                                       2
                                                                        NOTE:
                                                                        USE CANOPY PLATE IN CASE OF
                                                                                                           Glide the canopy plate on the
                                                                        FALSE CEILING.(IF DOWNROD IS
                                                                        NOT FULLY VISIBLE).
                                                                                                           down rod and use the bottom
                                                                                                           canopy.
03                                                              Blade assembly
                                                                Align the holes on the blade shank with
                                                                the motor holes. Securely fasten the blades
                                                                with the screws and washer provided.
04                                          Downrod
                                            Bottom
                                            Canopy
                                            Screw
                                                                Hanging the fan
                                                                Insert the screw to assemble the shaft and
                                                                the down rod. Insert the washer, nut and
                                                                R-Pin in the sequence depicted in the
                                            Connector
                                                                illustration below. Pull down the canopy to
                                                                cover the splice connector and screws.
                                                  Nut   Spring washer
                                      R pin                Hex screw
05
                                                 Height & adjustments
                                                 For optimal performance and safety, the fan
                  Ceiling                        blades should have at least 1 foot of
                             At least 1 foot     clearance from the ceiling. For low height
                                                 ceiling, refer step 2. Keep objects at least 2
                                                 feet away from the blade tips to reduce
                             At least 7.6 feet
                                                 injury or risk. The fan should be hung at least
                                                 7.6 feet from the floor to the blades.
                     Floor
06
                                                 Electrical wiring instruction
                                                 Rotate the splice connector anticlockwise
                                                 to remove it from the power wires (red,
                                                 black). Twist it with the input supply wires,
                                                 then insert the splice connector and rotate
                                                 clockwise to lock it securely.
OPERATING YOUR ATOMBERG CEILING FAN
1.    Power 'ON' the ceiling fan using switch on the panel in the room.
2.    The LED indicator flashes ‘ON’ when power supply is restored.
3.    Use your remote to operate the ceiling fan.
4.    If you are leaving the room or facility for a long duration or on holiday, then
      power 'OFF' the ceiling fan using the switch on the panel.
Note: The product complies with the requirement of IS 374:2019, IS 302-2-80:2017 in
conjunction with IS 302-1:2008 with all applicable amendments.
MAINTENANCE
Periodic cleaning of your ceiling fan is the only maintenance needed.
When cleaning, use only a soft lint-free cloth or brush to avoid scratching the smooth
paint finish. You can use moist cloth to remove stains if any. However, do not use water
directly. Abrasive cleaning agents are not required and should be avoided to prevent
damage to the outer finishing.
    USING YOUR REMOTE
                                   Remote
                   On/Off                       Function      Description                        Indication
                                     key
                                      1        Speed 1      Sets the fan
                                                            to lowest speed
                   Speed control
                   Boost speed
                                      2        Speed 2      Sets the fan
                                                            to speed 2
                   Sleep mode         3        Speed 3      Sets the fan
                                                            to speed 3
                                                                                                  LED Blinks
                                      4        Speed 4      Sets the fan
                   LED On/Off                               to speed 4
                   Timer mode         5        Speed 5      Sets the fan
                                                            to speed 5
                                      B        Boost        Sets the fan
                                               Speed        to highest speed
                                   Longlasting AAA batteries are used in the remote
Sleep mode adds smart comfort, as the temperature drops over the night and if you
wish to auto-reduce the speed. Sleep mode will not work if fan is off.
With Timer mode you can switch OFF/ON the fan automatically after set hours to
further save energy.
 Remote
             Function                                                       Indication
   key
 Timer    Timer button operation:                                    LED will follow a turn ON-fade out
          First Press: Sets timer for 1 Hr                           pattern of once each for the number
          Second Press: Sets timer for 2 Hr                          of hours the timer is set for:
                                                                     1 hour: Once
          Third Press: Sets timer for 3 Hr
                                                                     2 hours: Twice
          Fourth Press : Sets timer for 6 Hr                         3 hours: Thrice
          Fifth Press : Reset                                        6 hours: Six times
                                                                     OFF: Max brightness for 2 sec, then fade in 1 sec
          SLEEP button operation:                                    Sleep mode ON: LED lights up and
  Sleep
          First Press: Turn ON SLEEP mode                            fades out slowly over 1 second.
          Second Press: Turn OFF SLEEP mode
                                                                     Sleep mode OFF: LED stays ON at full
          Sleep Mode working:                                        brightness for 2 seconds, then fades
          After initial 2 Hrs a Speed reduces by 1 step.             out in 1 second.
          Then after next 2 Hrs a Speed reduces by another
          1 step and fan continues to run at this speed.
  LED     LED On/Off                                                 First Press: Turn ON LED mode
                                                                     Second Press: Turn OFF LED mode
   TROUBLESHOOTING
Your ceiling fan is built to last with a durable body and reliable electronics.
If issues arise, refer to the guidelines or contact a local electrician or
service engineer for assistance.
Problem              Cause                                            Solution
Fan does       Fuse down / MCB shut off         Check fuse of the MCB on the mains.
not start
               Loose wire connection to fan     Check the wire connection and restore the connection
               or to the switch on the panel.
               Fan still does not start         Please contact the service number provided. It is recommended
               Regulator is connected to        that the regulator should not be connected to this ceiling fan
               the fan.                         and it is instead controlled using the remote provided with it.
Fan            Bearing inside the housing       This ceiling fan is designed to be longlasting. However, after
making         has problems.                    many years of use the bearing may wear off and may need to
noise                                           be replaced.
               Fan blades are not seated        Make sure the blades are properly fastened to the body. Loose
               properly on the motor.           connection may cause accidents.
               Shackle kit rattling.            Make sure that the screws and nuts are securely fastened
                                                along with washer provided.
               Canopy is touching the           Make sure that the canopy and/or the wire that connects
               body / Canopy is touching        the fan are not touching the body of the motor.
               the ceiling.                     Make sure that the canopy is not touching the ceiling.
Fan is         Nut holding motor shaft          Securely fasten the nut and bolts along with washers as per
wobbling       and the down rod is loose/       the instructions provided in this manual.
               Nut holding down rod and
               shackle kit is loose/Screws
               in shackle kit and the ceiling
               hook are loose.
               Fan blades are not seated        A common mistake is fixing the blade in the reverse direction.
               properly on the motor.           Please set it right and securely fasten the screws.
               Fan blades are out of            Make sure that the blades are not bent during cleaning. Also,
               balance.                         interchanging them helps balance the blades.
Continouous    Regulator not bypassed.          Make sure the regulator is eliminated from the connection.
LED blinking
Restart        Blades have wrong sweep.         Check the sweep of blades with the fan sweep before
& speed                                         assembling.
variation
        HOW TO REGISTER THE WARRANTY?
ONLINE REGISTRATION
• Log in to www.atomberg.com
• Navigate to “register-warranty-card”
• Enter product serial number/barcode (mentioned on the warranty card/box)
  and other details.
                                                                              SCAN QR code for
VIA CALL
• Call us on "84484 49442"
                                                        or
• Select your language
• Select '3' for warranty registration
• You will receive a warranty link
  via 'SMS' or a call back for                                               warranty registration
  remaining details
FAN LIMITED WARRANTY
Atomberg Technologies Private Limited warrants that this product is to be free from any
manufacturing defects in material and workmanship under normal use from the date of
purchase as evidenced by the purchase receipt. This warranty provided by Atomberg
Technologies Private Limited to you is for a period of 1+1 years*.
• Warranty duration:
    Part Name                            Warranty duration from Date of Purchase**
    Motor**                              1+1* (years)
    Accessories: Downrod, Canopy
                                         Against transit damage within 7 days of delivery
    Shackle kit, Battery, etc.
    Remote, Blade**                      1 Year
This warranty card is an addition and does not imply any loss of statutory rights.
After warranty card registration
*                                   **
                                      Against Manufacturing defects
Note: All the transit damage or missing items cases should be registered within 7 days
of product delivery to pass the warranty claim.
     WARRANTY TERMS AND CONDITIONS
• The warranty explicitly provided for herein is the sole warranty provided in
  connection with the product and no other warranty, expressed or implied, is
  provided.
• Atomberg assumes no responsibility for any other claims, especially ones not stated
  in this warranty.
• The company’s liability will never exceed the value of the product.
• The company will not be responsible for delay in repair/service due to unavoidable
  circumstances.
• This warranty is only valid within the states and union territories of India.
• No other written or oral warranties apply, and no other agent, employee, dealer or
  any other person is authorized to give any warranties (explicit or otherwise) on
  behalf of Atomberg.
• This warranty does not include and expressly excludes:
   - Loss or damage to the motor or any accessory caused by normal wear and
      tear rather than due to defect in materials or workmanship.
   - Loss or damage resulting from improper installation or other failure to
      comply with instructions given in your owner’s manual.
   - Loss or damage resulting from conditions beyond our reasonable control,
      including without limitation, repairs not made at our factory or authorized
      service provider, use of parts or accessories not provided to you as part of
      this warranty by our factory or authorized service providers or mishandling,
      unreasonable use, misuse, abuse, modifications or other damages caused
      by you or a third party to your fan while not in our possession.
To know more about warranty terms and latest guidelines kindly visit related section on
www.atomberg.com
How to avail this service under warranty terms:
1.    Registering your barcode is mandatory to avail warranty services.
2.    Your sales bill with full purchase details and this fully completed warranty card
      must be presented when warranty services are required.
3.    This warranty service must be performed at our factory, or with authorized
      service providers who are affiliated to the atomberg warranty system.
4.    When returning the product for warranty service, please pack it carefully,
      enclose the bill, the warranty card and the instructions for repair.
5.    If the warranty card is lost, then it cannot be re-issued.