0% found this document useful (0 votes)
12 views2 pages

Renesa

The document provides a comprehensive guide for the Atomberg RENESA ceiling fan, detailing troubleshooting steps, installation instructions, and operational features. It emphasizes the importance of bypassing the regulator for optimal performance and highlights the fan's energy efficiency and smart functionalities like TIMER and SLEEP modes. Safety precautions and maintenance tips are also included to ensure proper usage and longevity of the fan.

Uploaded by

tgr82vb7s4
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
12 views2 pages

Renesa

The document provides a comprehensive guide for the Atomberg RENESA ceiling fan, detailing troubleshooting steps, installation instructions, and operational features. It emphasizes the importance of bypassing the regulator for optimal performance and highlights the fan's energy efficiency and smart functionalities like TIMER and SLEEP modes. Safety precautions and maintenance tips are also included to ensure proper usage and longevity of the fan.

Uploaded by

tgr82vb7s4
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Problem Cause Solution

WARNING
Fan does Fuse down / MCB shut off Check fuse of the MCB on the mains.
not start
DO NOT use the fan regulator as the fan is operated using a remote.
Loose wire connection to Check the wire connection and restore
Eliminate the regulator by using a direct connection from the switch to the fan. fan or to the switch on the the connection
panel
SLEEP mode adds smart comfort, as the temperature drops over the night and if
you wish to auto-reduce the speed. Fan still does not start Please contact the service number
provided.
With TIMER mode, you can switch OFF or switch ON the fan automatically after
set hours to further save energy.
Regulator is connected to
the fan
It is recommended that the regulator
should not be connected to this ceiling
fan and it is instead controlled using
CEILING FAN
Remote key Function Description LED status
the remote provided with it.
1 Speed 1 Sets the fan to speed 1 One LED will glow for 1 sec.
Fan making Bearing inside the housing This ceiling fan is designed to be
2 Speed 2 Sets the fan to speed 2 Two LED will glow for 1 sec. noise has problems longlasting. However, after many years
3 Speed 3 Sets the fan to speed 3 Three LED will glow for 1 sec. of use the bearing may wear off and
may need to be replaced.
4 Speed 4 Sets the fan to speed 4 Four LED will glow for 1 sec. Fan blades are not seated Make sure the blades are properly
5 Speed 5 Sets the fan to speed 5 Five LED will glow for 1 sec. properly on the motor fastened to the body. Loose connection
B Boost SpeedSets the fan to boost All LEDs blink thrice. may cause accidents.
Shackle kit rattling Make sure that the screws and nuts are
Timer OFF Timer/ • Fan automatically Timer 1-One LED blinks twice.
securely fastened along with washer
Wakeup switches OFF/ON after the Timer 2-Two LEDs blink twice. provided.
Timer set hours (1,2,3 & 6 Hrs). Timer 3 -Three LEDs blink twice.
• Number of LEDs suggest Timer 6 -All LEDs blink twice. Fan is Nut holding motor shaft Securely fasten the nut and bolts along
number of hours set. Timer Disable -Odd and Even wobbling and the down rod is loose with washers as per the instructions
• Press the Timer key 5 times, LEDs blink in a pattern thrice. provided in this manual.
to disable Timer or once Nut holding down rod and Securely fasten the nut and bolts along
after 6 Hr timer indication. shackle kit is loose with washers as per the instructions
provided in this manual.
Sleep Reduce • Sleep mode works for Sleep Mode Enable - Four LEDs
speed of 4 Hours. Speed is reduced in square blink twice. Screws in shackle kit and Securely fasten the nut and bolts along
fan by 1 by 1 every 2 hours. Sleep Disable - Odd and Even the ceiling hook are loose with washers as per the instructions
provided in this manual.
every 2 Afterwards, the fan LEDs blink in a pattern thrice.
hours for continues to run on a Fan blades are not seated A common mistake is fixing the blade in
4 hours reduced constant speed. properly on the motor the reverse direction. Please set it right
and securely fasten the screws.
Fan speed will not reduce
below speed 1. Fan blades are Make sure that the blades are not bent
out of balance during cleaning. Also, interchanging
•If sleep mode is already them helps balance the blades.
set and sleep key is pressed,
it will disable sleep mode. Restart/speed Regulator not bypassed Make sure the regulator is eliminated
LED LED ON/OFF Turn ON/OFF LEDs. All six LEDs will glow. variation from the connection.
Blades have wrong sweep Check the sweep of blades with the fan
Note: Sleep mode will not work if fan is off. sweep before assembling.
CONTROL FAN SPEED WITHOUT REMOTE
The fan's main switch can be used to control its speed. Turn the fan's switch OFF
MAINTENANCE
& ON repeatedly to set the fan to the desired speed. Delay between the toggling Periodic cleaning of your ceiling fan is the only maintenance needed.
between the OFF and ON buttons should be approximately 1 second. If toggling is When cleaning, use only a soft lint-free cloth or brush to avoid scratching the
too fast or too slow, it will not work. While toggling, the LEDs will glow to indicate smooth paint finish. You can use moist cloth to remove stains if any. However, do
the speed of the fan. Refer to the below table to control the fan using the switch. not use water directly. Abrasive cleaning agents are not required and should be
avoided to prevent damage to the outer finishing.
Toggle (Turn
switch OFF Speed Descriptions LED status WARNING
and ON) MOTE WITH
RE
Do not use water when cleaning your ceiling fan. It could damage the motor by
1 time Previous Fan runs at the No indication causing short-circuit and create the possibility of an electrical shock.
speed same speed
Do not bend the blades while cleaning. A bend in the blade may result in unstable

DE
BOOS
2 times Speed 1 Lowest speed 1 1 LED will glow and turn off fixing and affect the air delivery.

MO
after 1 second. SL R
E E P & TI M E

T,
3 times Speed 2 Speed 2 2 LEDs will glow and turn off
after 1 second.
4 times Speed 3 Medium speed 3 3 LEDs will glow and turn off

INSTRUCTION
after 1 second.
5 times Speed 4 Speed 4 4 LEDs will glow and turn off
after 1 second.
6 times

7 times
Speed 5

Boost
High speed 5

Boost mode speed


5 LEDs will glow and turn off
after 1 second.
6 LEDs will glow and turn off
after 1 second.
ATOMBERG TECHNOLOGIES PVT LTD
MANUAL
Corporate office: Rupa Solitaire, Office No. 1205 IMPORTANT NOTE:
TROUBLESHOOTING Millenium Business Park, Mahape, Navi Mumbai 400 710.
Read this manual carefully before installing or
Your ceiling fan is designed to be longlasting with a strong body and well-tested Manufacturing unit: Plot No D -130 B, TTC Industrial Area
electronics, however if any problem arises, please refer to the guidelines shared. operating your new Atomberg RENESA Ceiling Fan.
Please contact a local electrician or service engineer if you need any help.
Shirawane, Navi Mumbai 400 706. Ensure you save this manual for future reference.

290mm X 210mm: same size artwork


Dear Customer, BIG ENERGY SAVINGS Step 5.
Congratulations on purchase of ATOMBERG'S super efficient RENESA ceiling fan. Atomberg is India's most energy-efficient ceiling fan. A super-efficient BLDC motor Ceiling WARNING
Please read this guide before using this product. It would also be advisable to technology is used, which consumes very little energy. Atomberg fans consumes
store this guide safely for future reference. just 1/3rd of the power used by ordinary induction fans. Ordinary induction fans At least 1 foot The fan blade must be hung with at least 1 foot of
run on 75watts, whereas Atomberg fans run on just 28watt at full speed. clearance from the ceiling for optimal performance
PACKAGE CONTENTS and safety.
There is huge saving potential for households, and institutions such as hospitals,
colleges, schools and commercial spaces. Any object next to the fan must be at least 2 feet
At least 7 feet away from the tip of the fan blade to reduce chances
INSTALLATION Shackle kit of risk or injury.
Assembly: Top canopy The fan must be hung with at least 7 feet of
Mandatory Step: clearance from the floor to the blades.
Bypass or eliminate the regulator from Floor
Down rod
MOTOR 3 ALUMINIUM DOWN SHACKLE the connection before installing on Atomberg
BLADES ROD KIT fan for optimal performance ELECTRICAL WIRING INSTRUCTIONS
Bottom canopy
Step 6. Make the correct wire connections to
Blade operationalise the fan.
Shaft with motor Adjust the canopy as required
The picture shown above depicts the exact order of placement of various parts. Color codes of the wires may vary from region to
region. Please check your state or country notifications
Step 1. regarding the same.
2 WARRANTY
CANOPIES REMOTE MANUAL Carefully remove the motor from the box and
CARD WARNING
keep it on soft padding to prevent it from getting
scratched. Motor
WARNING Any connection to wires must be securely sealed using electrical insulation tape
to prevent electric shock or fire hazard.
Do not install or use fan if any part is damaged or missing. Step 2. Avoid pinching of wires between the shackle kit, down rod and ceiling hook
Insert the canopy into the shaft and securely, Ceiling assembly to prevent electric shock or fire hazard.
This product is designed to be used only with those parts or accessories supplied attach the shackle to the hanger or ceiling
with this product and/or any accessories designed specially for use with this Hook
hook using the screws provided with the package.
product by Atomberg. Any such use of other parts or accessories Fasten the nut, and make sure that you fit the USING YOUR CEILING FAN
may turn the product warranty null and void, and may result in personal injury safety nut, washer and the R-pin to prevent slipping. Congratulations! You have successfully installed your new ceiling fan using the
or property damage as well. Adjust the top canopy so that it covers both the instructions provided in this guide.
assembly and the connection. 1 Restore the electrical power.
SAFETY INSTRUCTIONS 2 Power 'ON' the ceiling fan using switch on the panel in the room. The LED
Step 3.
Be careful of the fan and blades while cleaning, painting, or working near the fan. indicator flashes ‘ON’ when power supply is restored.
Align the holes on the blade shank with the motor
Always turn off the power to the ceiling fan before servicing.
holes. Securely fasten the blades with the screws WARNING
Do not put your hand or any other objects near the fan blades while the fan is running. and washer provided.
Do not modify the blade design to change the air flow. “Not recommended for use in high humid areas" like Washroom, direct or indirect The performance of the fan gets affected if the regulator is not bypassed, and
exposure to water entries etc. may lead to speed variations, restarting or low speed. Eliminate regulators by
using a direct connection from the switch to the fan.
WARNING
WARNING 3 Use your remote to operate the ceiling fan.
Observe the following to reduce the risk of fire, electric shock or injury: 4 If you are leaving the room or facility for a long duration or on holiday, then
If the blades are not secured properly with the screws and the washer, it may power 'OFF' the ceiling fan using the switch on the panel.
Only use this unit in the manner intended by Atomberg. If you have any cause injury during operation. Also, an imbalanced fan may cause damage to
questions regarding the product, please contact Atomberg. the motor and reduce the lifetime of the fan. HOW TO USE YOUR REMOTE
Before servicing or cleaning, switch off the main power panel and switch. Any damage caused by incorrect installation and wrong practices followed while
connecting the fan are not covered under the warranty terms. Please check the
Wiring of the fan must be done only by a qualified and certified electrician. warranty terms in detail. ON/OFF The remote provided along with your
Do not turn on the fan until the blades are securely fastened to the ceiling fan. CONTROL ceiling fan is ergonomically designed.
FEATURES The soft controls on the remote are
SPEED
India's most energy-efficient RENESA ceiling fan • More than 65% energy saving as HOW TO HANG THE FAN CONTROL
longlasting.
compared to an ordinary fan • Highest service value (air delivery/power consumed)
in India • Runs 3 times longer on inverter resulting in longer battery runtime • Smart
Step 4. BOOST
MODE
sensorless algorithm for greater reliability • No heating of fan even after long hours Insert the screw to assemble the shaft and the down rod. Insert the washer, nut and
SLEEP
of runtime, resulting in an extra-long life • Consistent speed even at low voltages R-Pin in the sequence depicted in the illustration below. Pull down the canopy to MODE
cover the connector box.
• Easy speed controls using a smart remote • LED indications for easy remote use Spring LED
• TIMER feature automatically switches OFF the fan when fan is running state and Down rod
Nut washer CONTROL
switches ON the fan when fan is in OFF state • SLEEP will work for only 4 hours TIMER
of Sleep keypress. For the first 2 hour, it will reduce speed by 1, and then after the MODE
Canopy
next 2 hours, it will be reduced by 1 speed • Full copper motor and double ball-bearing
for better stability and longer life • Aluminum body and blade, resulting in zero rust
• Zinc-plated parts and accessories for rust-free life • Protective coating over
electronics for better resistance against moisture • All fans are tested for durability Hex Longlasting AAA batteries are used in the remote
in extreme conditions before shipping. R pin screw