Bro Flooring ESD Us
Bro Flooring ESD Us
ohms
Epoxy
Sikafloor 200
́ ́ * ́
ESD
Sikafloor 200C
́ ́ ́ *
ESD
Sikafloor 260
́ ́ ́ *
ESD
Sikafloor 264 ECF ́ * ́ *
Novolac
Sikafloor 270
́ ́ ́ *
ESD
Urethane
Sikafloor 340
́ ́ * ́
ESD
́ Meets the standard
* Doesn’t meet the standard
Standard/Test Method Test Method Sikafloor System
ANSI/ESD STM7.1 All Sikafloor ESD Systems
ANSI/ESD S20.20 - 2021 Flooring/Footwear ANSI ESD All Sikafloor ESD Systems
STM97.1
Body Voltage ANSI ESD STM97.2 All Sikafloor ESD Systems Except
Sikafloor 264 ECF
Sikafloor 200C ESD
MIL DoD 4145.26/6055.9 ASTM F150-06(18) Sikafloor 260 ESD
Sikafloor 270 ESD
Sikafloor 264 ECF
Airforce/Air Ops/Hangar & Fuel ASTM F150-06(18) Sikafloor 340 ESD
NFPA 77 Flammable LP&G ASTM F150-06 (18) Sikafloor 200C or Sikafloor 260 ESD
Market Segment Standard Test Method Range/Value Sikafloor System
Electronics, other than explosives -
Any military or DoD/DoD contractor
activity that mirrors civilian electronics Formerly MIL-1686C Refer to ANSI ESD See ANSI S20.20 Sikafloor 200 ESD
covered in ANSI S20.20; including radio/ superseded by ANSI STM7.1 -2021 Sikafloor 200C ESD
radar repair & maintenance, computers, S20.20 -2021 Sikafoor 260 ESD
medical instrumentation/devices, and Sikafloor 270 ESD
other similar electronic
equipment, network operation center
(NOC) electronic devices and processes.
Government Agencies - NASA, NSA, Depends on agency: ASTM F150-06(18) 2.5 x 106 to <1.0 x 109
DARPA, DHS, TSA & Quasi- FAA = FAA-STD019F ohms unless other- Sikafloor 200C ESD
governmental entities such as civilian wise specified
operated space/orbital ops.
CONCRETE SLAB
900_020816_0022A1_1703_en
1 - PREPARATION OF
SUBSTRATE
SCREW ALLEN SCREW WITH AN ALLEN KEY INTO
THE ANCHOR, SO THAT 16 mm OF THE ALLEN
SCREW STICK OUT
PREPARE THE SUBSTRATE ACCORDING TO THE PDS
ISOLATED EARTHING WIRE
SIKAFLOOR®-156/161, PRIMING OF THE WHOLE AREA AND
FILLING OF GROOVE WITH AN EPOXY MORTAR 900_020816_0022A5_1703_en THE CUT-OUT
5 - CONNECTION (GROUND
GROOVE FOR THE ISOLATED WIRE WITH A DEPTH OF > 10 mm
VIEW) AFTER CURING OF THE SIKAFLOOR®-220 W AND A WIDTH OF 5mm. APPROX.
CONDUCTIVE PROCEED TO REMOVE THE PLASTIC
TUBE, CLEAN THE HEAD OF THE ALLEN SCREW
PROPERLY AND FIX THE BRASS EYELET USING THE
DRILL A HOLE IN THE CENTRE OF THE CUT-OUT WITH SELF-LOCKING NUT AT THE ALLEN SCREW.
DIAMETER OF 8 mm AND A DEPTH OF > 50mm THE CONNECTIONS OF THE ISOLATED WIRE HAVE CONCRETE SLAB
REMOVE ALL DUST, LOOSE AND FRIABLE MATERIAL TO BE EXECUTED BY A LICENSED ELECTRICAL 900_020816_0023A1_1703_en
AND INSERT ANCHOR. ANCHOR MUST BE FLUSH ENGINEER
WITH THE FLOOR SURFACE. 1 - PREPARATION OF
900_020816_0022A2_1703_en
SUBSTRATE AND PRIMING
2 - PRIMING AND
INSTALLATION OF ANCHOR
FIXING WITH COPPER TAPE
FIX THE LARGE (D = 60 mm) AND THE MEDIUM SIZE FAN OUT ISOLATED WIRE
(D = 30mm) WASHER WITH THE NUT (M6) AT THE 900_020816_0022A5_1703_en
FILLING OF GROOVE WITH AN EPOXY MORTAR.
ALLEN SCREW 5 - CONNECTION (CROSS
SECTION)
THE CONNECTIONS OF THE ISOLATED WIRE HAVE TO BE
EXECUTED BY A LICENSED ELECTRICAL ENGINEER
900_020816_0022A4_1703_en
8048 Zürich
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products
4 - CONDUCTIVE PRIMING when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only applies to the Switzerland
application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in
the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's Technical Service prior to Tel: +41 584364040
using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and
purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local
Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com
900_020816_0023A2_1703_en
2 - INSTALLATION OF ISOLATED
WIRE (GROUND VIEW)
900_020816_0023A3_1703_en
3 - CONDUCTIVE LAYER
FIX THE SMALL PLASTIC TUBE ONTO THE ALLEN SCREW
AND FASTEN TIGHTLY PRIOR TO THE APPLICATION OF THE
SIKAFLOOR® PRODUCTS
APPLICATION OF SIKAFLOOR®-XYZ AS/ECF/ESD
PREPARE THE SUBSTRATE ACCORDING TO THE PDS APPLICATION OF SIKAFLOOR®-220 W CONDUCTIVE APPLICATION OF SIKAFLOOR®-XYZ AS/ECF/ESD
CONCRETE SLAB
900_020816_0024A1_1703_en 900_020816_0024A4_1703_en 900_020816_0023A4_1703_en
1 - PREPARATION OF 4 - CONDUCTIVE 4 - CONDUCTIVE
SUBSTRATE AND PRIMING PRIMING AND COATING COATING
900_020816_0024A2_1703_en 900_020816_0024A5_1703_en
2 - INSTALLATION OF 5 - CONNECTION
ANCHOR (CROSS SECTION)
FIX THE LARGE (D = 60 mm) AND THE MEDIUM SIZE LARGE (D = 60 mm) AND THE MEDIUM SIZE (D =
(D = 30mm) WASHER WITH THE NUT (M6) AT THE 30mm) WASHER WITH THE NUT (M6) AT THE ALLEN
ALLEN SCREW SCREW
PLACING OF MIN. TWO COPPER STRIPS DISPLAYED
AT EITHER SIDE OF THE DRILL-HOLE
900_020816_0024A3_1703_en
3 - FIXING OF COPPER 900_020816_0024A5_1703_en
STRIPS 5 - CONNECTION
(GROUND VIEW)
Black
The above are for use with Sikafloor® 200 ESD and Sikafloor® 340 ESD only. Sikafloor® 340 ESD is not available in
Dark Gray. Please consult Sika Industrial Flooring for further information and pricing. Because of the limitations of
process color printing, the color samples contained herein are close approximations of actual colors and should not be
relied upon for true color. Final color matching should be made with an actual sample of the product, color and texture
to be used. Custom colors are available. Our most current local Sales Conditions shall apply. Please consult the most
current local Product Data Sheet prior to any use.
COLOR SELECTION GUIDE FOR
SIKAFLOORS 260 ESD & 270 ESD
The above are for use with Sikafloor® 260 ESD and Sikafloor® 270 ESD only. Please consult Sika Industrial Flooring
for further information and pricing. Because of the limitations of process color printing, the color samples contained
herein are close approximations of actual colors and should not be relied upon for true color. Final color matching
should be made with an actual sample of the product, color and texture to be used. Custom colors are available. Our
most current local Sales Conditions shall apply. Please consult the most current local Product Data Sheet prior to any
use.
COLOR SELECTION GUIDE FOR
SIKAFLOOR 264 ECF
The above are for use with Sikafloor® 264 ECF only. Please consult Sika Industrial Flooring for further information
and pricing. Because of the limitations of process color printing, the color samples contained herein are close
approximations of actual colors and should not be relied upon for true color. Final color matching should be made with
an actual sample of the product, color and texture to be used. Custom colors are available. Our most current local
Sales Conditions shall apply. Please consult the most current local Product Data Sheet prior to any use.
GLOBAL Sikafloor® ESD SOLUTIONS
SOLUTIONS FOR THE MARKETS IN EMEA
DIN EN 1081 IEC 61340-5-1 IEC 61340-5-1 IEC 61340-5-1 ATEX 137/TRBS 2153 DIN VDE 0100-410
Resistance to Ground (IEC 61340-4-5) (IEC 61340-4-1) (IEC 61340-4-1) European Standard (IEC 60364-4-1)
Rg <1 x 108 Ω System Test: Walking Test (BVG) Resistance to Ground Resistance to Ground Isolation Resistance
<1 x 109 Ω <100 Volt RG <1 x 109 Ω RG <1 x 109 Ω >50k Ω
Sikafloor 381 AS ́ * * * ́
ESD system with very low body voltage generation
Sikafloor 235 ESD * * ́ ́ ́
Sikafloor 262 AS N +
Sikafloor 305 W ESD * * ́ ́ ́
WE ARE SIKA
Sika is a specialty chemicals company with a leading position in the development and production of systems and products for bonding,
sealing, damping, reinforcing and protecting in the building sector and the motor vehicle industry. Sika’s product lines feature concrete
admixtures, mortars, sealants and adhesives, structural strengthening systems, industrial flooring as well as roofing and waterproofing
systems.
UTION
SOL
LE
AB
A S U STA I N
M PLIA NT
CO
®
1
N
ISO 9001 LEED T IO
Certificate # FM 69711
V4 OP
RC 14001
Certificate # RC 510999