Sikafloor® ESD CONTROL FLOORING

Sikafloor® ESD CONTROL FLOORING


A UNIQUE APPROACH TO ELECTROSTATIC CONTROL
In industries where electronic components or volatile chemicals are involved, static electricity can result in significant
damage, injury and financial loss. Protect your work environment against electrostatic discharge with Sikafloor® ESD Control
Flooring Systems. Each facility’s flooring needs and environments vary significantly. Sika’s dedication to ESD research
and development allows us to offer a wide range of ESD flooring preferences to precisely match your unique facility
specifications and decor.
ANSI/ESD S 20.20 ANSI ESD S20.20- ASTM F 150-06 (18) ASTM F 150-06 (18)
-2021 2021 (DIF) Surface to
(ANSI/ESD STM97.1) (ANSI/ESD STM97.2) Surface Surface to >1.0 x 106 - <1.0 x 109
<1.0 x 109 ohms Walking Test (BVG) Ground ohms
<100 volt >2.5 x 10 - <1 x 10
4 6

ohms
Epoxy
Sikafloor 200
́ ́ * ́
ESD
Sikafloor 200C
́ ́ ́ *
ESD
Sikafloor 260
́ ́ ́ *
ESD
Sikafloor 264 ECF ́ * ́ *
Novolac
Sikafloor 270
́ ́ ́ *
ESD
Urethane
Sikafloor 340
́ ́ * ́
ESD
́ Meets the standard
* Doesn’t meet the standard
Standard/Test Method Test Method Sikafloor System
ANSI/ESD STM7.1 All Sikafloor ESD Systems
ANSI/ESD S20.20 - 2021 Flooring/Footwear ANSI ESD All Sikafloor ESD Systems
STM97.1
Body Voltage ANSI ESD STM97.2 All Sikafloor ESD Systems Except
Sikafloor 264 ECF
Sikafloor 200C ESD
MIL DoD 4145.26/6055.9 ASTM F150-06(18) Sikafloor 260 ESD
Sikafloor 270 ESD
Sikafloor 264 ECF
Airforce/Air Ops/Hangar & Fuel ASTM F150-06(18) Sikafloor 340 ESD
NFPA 77 Flammable LP&G ASTM F150-06 (18) Sikafloor 200C or Sikafloor 260 ESD
Market Segment Standard Test Method Range/Value Sikafloor System
Electronics, other than explosives -
Any military or DoD/DoD contractor
activity that mirrors civilian electronics Formerly MIL-1686C Refer to ANSI ESD See ANSI S20.20 Sikafloor 200 ESD
covered in ANSI S20.20; including radio/ superseded by ANSI STM7.1 -2021 Sikafloor 200C ESD
radar repair & maintenance, computers, S20.20 -2021 Sikafoor 260 ESD
medical instrumentation/devices, and Sikafloor 270 ESD
other similar electronic
equipment, network operation center
(NOC) electronic devices and processes.

Military (Direct-to-Branch Mil Ops)


Same as civilian DoD contractors, only
directed to, for or on behalf of the DoD 6055.9-STD
direct branch, i.e. Army, Navy, Airforce, Sikafloor 200C ESD
et al. Quasi-Military agencies including
Missile Defense Agency (MDA). May
include NASA if engaged in military
based pursuits (defense satellite ops).
A common example is a USAF hangar
or fuel cell maintenance facility.
Military Aviation Ops/Airforce
(hangars, fuel cell maintenance) -
Same as civilian DoD contractors, only
directly contracted to, for or on the ETL 964, AFI 1065 Cites NFPA 99, 1.0 x106 to <1.0 x 109
behalf of the direct branch, i.e. Army, (A6.7 & 13.4) defer to ASTM ohms, Sikafloor 340 ESD
Navy, Airforce. Quasi-Military Agencies F150-06(18) resistance from
including Missile Defense Agency floor to ground
(MDA). May include NASA if engaged must be >2.5 x 104
in military based pursuits (satellite
defense ops). A common example is a
USAF hangar or fuel cell maintenance
facility.

Government Agencies - NASA, NSA, Depends on agency: ASTM F150-06(18) 2.5 x 106 to <1.0 x 109
DARPA, DHS, TSA & Quasi- FAA = FAA-STD019F ohms unless other- Sikafloor 200C ESD
governmental entities such as civilian wise specified
operated space/orbital ops.

DoD Civilian Contractors - Civilian


controlled business entity engaged in
manufacturing, assembling or storing DoD 4145.26 (C6, 4.7 ASTM F150-06(18) Not to exceed 1 Sikafloor 200C ESD
materiel including ordinance, Conductive Floors, megohm, flooring
munitions, explosives, delivery/ Tabletops, Foot- and footwear
deployment systems (rocket missile, wear), ref. C6, 47.5.1 combination
projectile), propellants, and other Test Criteria
energy producing materials
Attributes Build Up Sikafloor Products

Standard ESD System


Primer Coat:
́ Electrostatic disipative Sikafloor 161 @ 8mils
́ Good chemical & mechnical
resistance Top Coat:
Sikafloor 200 ESD @ 16 mils
́ Easy to clean & maintain
́ Low odor/low VOC system

Standard Conductive ESD System


Primer Coat:
́ Electrostatic conductive Sikafloor 161 @ 8mils
́ Good chemical & mechnical Conductive Primer:
resistance Sikafloor 220 W @ 4mils
́ Easy to clean & maintain
Top Coat:
́ Low odor/low VOC system Sikafloor 200C ESD @ 16mils

Standard Prepigmented ESD System


Primer Coat:
́ Electrostatic conductive Sikafloor 161 @ 8mils
́ Good chemical & mechnical Conductive Primer:
resistance Sikafloor 222 W @ 4mils
́ Easy to clean & maintain
Top Coat:
́ Low odor/low VOC system Sikafloor 260 ESD @ 16mils
́ Available in nine standard
colors
Attributes Build Up Sikafloor Products

Prepigmented, High Build


ECF System Primer Coat:
Sikafloor 161 @ 8mils
́ Electrostatic conductive
throughout system Conductive Primer:
́ Very low body voltage Sikafloor 222 W @ 4mils
generation with ESD foot
wear Top Coat:
Sikafloor 264 ECF @ 16mils
́ Low odor/low VOC system
́ Available in 18 standard
colors

Chemical Resistant, Prepigmented


Primer Coat:
ESD System Sikafloor 161 @ 8mils
́ Novolac epoxy system
́ Excellent chemical Conductive Primer:
resistance Sikafloor 222 W @ 4mils
́ Very low body voltage Top Coat:
generation with ESD foot Sikafloor 270 ESD @ 16mils
wear

Chemical Resistant, Solvent Based


Primer Coat:
ESD System Sikafloor 161 @ 8mils
́ Excellent chemical &
mechanical resistance Standard Top Coat:
Sikafloor 340 ESD @ 4mils
́ Very low body voltage
generation with ESD foot Recommended 2nd Top Coat:
wear Sikafloor 340 ESD @ 4mils
́ Matte finish
Sikafloor® Earthing Kit

An electrostatic charge, which occurs during materials


contact and s­ eparation, has to be discharged via an ́ Prepare and prime the substrate in
earthing point. The Sikafloor® Earthing Kit, is a unique tool ­accordance with the relevant
box containing all of the necessary components for up to 10 Sikafloor® PDS.
earthing points. ́ When primer has cured, drill a hole:
diameter 1/32“, depth > 2“
Each earthing point is able to conduct to earth 3,200 ft². ́ Remove all dust, loose and friable
Ensure the longest distance between each earthing point material around the hole and insert a
in each room or area is a maximum of 30 ft. apart. In larger size 8 plastic plug. The plug must be
areas with longer d­ istances, additional earthing points must flush with the floor surface.
be installed in accordance with the Electrical Engineer’s ́ Screw the threaded dowel rod with a
requirements. hexagonal socket into the plastic plug

If site conditions or other constraints do not allow the


positioning of any additional earthing points that are ́ Fully bond the copper strips on both
required, then any longer distances (> 30 ft.) must be sides of the hole.
bridged by the use of additional adhesive copper tapes in ́ Place large (D = 2 3/8“) washer
accordance with the relevant specifications. All of the followed by the smaller (D=1 1/8“)
earthing points have to be connected to an appropriate washer over the threaded dowel rod
ring-main to ground them and this work must be carried out and secure with the nut (M6) so the
and approved by the responsible Electrical Engineer in washers are pressed onto the copper
accordance with all relevant local regulations. strips ensuring good contact.

́ Push the transparent plastic hose over


the threaded dowel rod so the hose fits
tightly.

́ Apply the selected Sikafloor conductive


primer and conductive wearing finish
ensuring all washers and copper tape
are completely covered.
́ After curing the S
­ ikafloor products,
remove the transparent plastic hose.
́ Clean the head of the threaded dowel
rod. Fix the brass eyelet using the
self-locking nut (M6) onto the threaded
dowel rod. Connect the grounding cable
with the brass eyelet.
́ Connect the earthing main cable with
the brass eyelet (only by a qualified
Electrical Engineer).
CAD DRAWINGS ARE AVAILABLE
For alternative situation Sika can provide detailed CAD drawings of the different possibilities to position
an earthing point. Please do not hesitate to ask your local Sika Technical Services Department for these.

PREPARE THE SUBSTRATE ACCORDING TO THE PDS

140-150 mm GROOVE FOR THE ISOLATED WIRE WITH A DEPTH


OF > 10 mm
LARGE (D = 60 mm) AND THE MEDIUM SIZE (D =
100 mm SIKAFLOOR®-156/161, PRIMING OF THE WHOLE 30mm) WASHER WITH THE NUT (M6) AT THE ALLEN
SCREW
AREA, CUT-OUT AND THE GROOVE
20 mm

MIN. TWO COPPER STRIPS DISPLAYED AT EITHER


SIDE OF THE DRILL-HOLE

CONCRETE SLAB
900_020816_0022A1_1703_en
1 - PREPARATION OF
SUBSTRATE
SCREW ALLEN SCREW WITH AN ALLEN KEY INTO
THE ANCHOR, SO THAT 16 mm OF THE ALLEN
SCREW STICK OUT
PREPARE THE SUBSTRATE ACCORDING TO THE PDS
ISOLATED EARTHING WIRE
SIKAFLOOR®-156/161, PRIMING OF THE WHOLE AREA AND
FILLING OF GROOVE WITH AN EPOXY MORTAR 900_020816_0022A5_1703_en THE CUT-OUT
5 - CONNECTION (GROUND
GROOVE FOR THE ISOLATED WIRE WITH A DEPTH OF > 10 mm
VIEW) AFTER CURING OF THE SIKAFLOOR®-220 W AND A WIDTH OF 5mm. APPROX.
CONDUCTIVE PROCEED TO REMOVE THE PLASTIC
TUBE, CLEAN THE HEAD OF THE ALLEN SCREW
PROPERLY AND FIX THE BRASS EYELET USING THE
DRILL A HOLE IN THE CENTRE OF THE CUT-OUT WITH SELF-LOCKING NUT AT THE ALLEN SCREW.
DIAMETER OF 8 mm AND A DEPTH OF > 50mm THE CONNECTIONS OF THE ISOLATED WIRE HAVE CONCRETE SLAB
REMOVE ALL DUST, LOOSE AND FRIABLE MATERIAL TO BE EXECUTED BY A LICENSED ELECTRICAL 900_020816_0023A1_1703_en
AND INSERT ANCHOR. ANCHOR MUST BE FLUSH ENGINEER
WITH THE FLOOR SURFACE. 1 - PREPARATION OF
900_020816_0022A2_1703_en
SUBSTRATE AND PRIMING
2 - PRIMING AND
INSTALLATION OF ANCHOR
FIXING WITH COPPER TAPE
FIX THE LARGE (D = 60 mm) AND THE MEDIUM SIZE FAN OUT ISOLATED WIRE
(D = 30mm) WASHER WITH THE NUT (M6) AT THE 900_020816_0022A5_1703_en
FILLING OF GROOVE WITH AN EPOXY MORTAR.
ALLEN SCREW 5 - CONNECTION (CROSS
SECTION)
THE CONNECTIONS OF THE ISOLATED WIRE HAVE TO BE
EXECUTED BY A LICENSED ELECTRICAL ENGINEER

APPLICATION OF SIKAFLOOR®-220 W CONDUCTIVE ON


≈ 50 mm THE EPOXY MORTAR IN THE CUT-OUT WITH AN
PLACING OF MIN. TWO COPPER STRIPS DISPLAYED OVERLAPPING OF APPROX. 5 cm. 900_020816_0023A2_1703_en
AT EITHER SIDE OF THE DRILL-HOLE APPLICATION OF2SIKAFLOOR®-XYZ
- INSTALLATION OF ISOLATED
AS/ECF/ESD
WIRE (CROSS-SECTION)
FILLING OF THE CUT-OUT WITH AN EPOXY MORTAR.
900_020816_0022A3_1703_en E.G. WITH SIKAFLOOR®-280 OR WITH
3 - FIXING OF COPPER SIKAFLOOR®-156/161 FILLED WITH A CONDUCTIVE
STRIPS AGGREGATE SUCH AS DORFNER CONDUCT OR SILICON
CARBIDE. MIXING RATIO APPROX. 1 PART RESIN : 5-7
PARTS CONDUCTIVE AGGREGATE FIXING WITH COPPER TAPE
FIX THE SMALL PLASTIC TUBE ONTO THE ALLEN
SCREW AND FASTEN TIGHTLY PRIOR TO THE
APPLICATION OF SIKAFLOOR®-220 W CONDUCTIVE
900_020816_0022A6_1703_en
FAN OUT ISOLATED WIRE
6 - FILLING AND COATING
FILLING OF GROOVE WITH AN EPOXY MORTAR.

SIKAFLOOR® CONDUCTIVE COATINGS 900_020816_0022A_1703_en


March 2017
APPLICATION OF SIKAFLOOR®-220 W CONDUCTIVE, Detailing of placing of an earthing point within the
ON THE WHOLE AREA, INCLUDING THE CUT-OUT Sika Services AG
area with a cutout (ECF/ESD floor coverings)
Template. For internal use only. Tüffenwies 16

900_020816_0022A4_1703_en
8048 Zürich
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products
4 - CONDUCTIVE PRIMING when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only applies to the Switzerland
application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in
the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's Technical Service prior to Tel: +41 584364040
using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and
purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local
Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

900_020816_0023A2_1703_en
2 - INSTALLATION OF ISOLATED
WIRE (GROUND VIEW)

APPLICATION OF SIKAFLOOR®-220 W CONDUCTIVE,


INC. CUT-OUT

900_020816_0023A3_1703_en
3 - CONDUCTIVE LAYER
FIX THE SMALL PLASTIC TUBE ONTO THE ALLEN SCREW
AND FASTEN TIGHTLY PRIOR TO THE APPLICATION OF THE
SIKAFLOOR® PRODUCTS
APPLICATION OF SIKAFLOOR®-XYZ AS/ECF/ESD
PREPARE THE SUBSTRATE ACCORDING TO THE PDS APPLICATION OF SIKAFLOOR®-220 W CONDUCTIVE APPLICATION OF SIKAFLOOR®-XYZ AS/ECF/ESD

SIKAFLOOR®-156/161, PRIMING OF THE WHOLE


AREA

CONCRETE SLAB
900_020816_0024A1_1703_en 900_020816_0024A4_1703_en 900_020816_0023A4_1703_en
1 - PREPARATION OF 4 - CONDUCTIVE 4 - CONDUCTIVE
SUBSTRATE AND PRIMING PRIMING AND COATING COATING

AFTER CURING OF THE SIKAFLOOR® MATERIALS


PROCEED TO REMOVE THE PLASTIC TUBE, CLEAN
SCREW ALLEN SCREW WITH AN ALLEN KEY INTO SIKAFLOOR® CONDUCTIVE COATINGS
THE HEAD OF THE ALLEN SCREW PROPERLY AND 900_020816_0023A_1703_en Sika Services AG
March 2017
THE ANCHOR, SO THAT 16 mm OF THE ALLEN FIX THE
Detailing of placing of an BRASS wire
earthing EYELETwithin
USING THE
the SELF-LOCKING
area (ECF/ESD floor coverings) Tüffenwies 16
SCREW STICK OUT Template. For internal use only.NUT AT THE ALLEN SCREW. 8048 Zürich
THE CONNECTIONS OF THE ISOLATED WIRE HAVE
DRILL A HOLE WITH DIAMETER OF 8 mm AND A TO BE EXECUTED BY A LICENSED ELECTRICAL Switzerland
DEPTH OF > 50mm The information contained herein and any other advice ENGINEER
are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
REMOVE ALL DUST, LOOSE AND FRIABLE MATERIAL Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com
AND INSERT ANCHOR. ANCHOR MUST BE FLUSH the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

WITH THE FLOOR SURFACE.

900_020816_0024A2_1703_en 900_020816_0024A5_1703_en
2 - INSTALLATION OF 5 - CONNECTION
ANCHOR (CROSS SECTION)

FIX THE LARGE (D = 60 mm) AND THE MEDIUM SIZE LARGE (D = 60 mm) AND THE MEDIUM SIZE (D =
(D = 30mm) WASHER WITH THE NUT (M6) AT THE 30mm) WASHER WITH THE NUT (M6) AT THE ALLEN
ALLEN SCREW SCREW
PLACING OF MIN. TWO COPPER STRIPS DISPLAYED
AT EITHER SIDE OF THE DRILL-HOLE

MIN. TWO COPPER STRIPS DISPLAYED AT EITHER


SIDE OF THE DRILL-HOLE

900_020816_0024A3_1703_en
3 - FIXING OF COPPER 900_020816_0024A5_1703_en
STRIPS 5 - CONNECTION
(GROUND VIEW)

SIKAFLOOR® CONDUCTIVE COATINGS 900_020816_0024A_1703_en


March 2017
Detailing of placing of an earthing point, Standard
Sika Services AG
Solution (ECF/ESD floor coverings)
Template. For internal use only. Tüffenwies 16
8048 Zürich
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products
when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only applies to the Switzerland
application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in
the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's Technical Service prior to Tel: +41 584364040
using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and
purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local
Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com
COLOR SELECTION GUIDE FOR
SIKAFLOORS 200 ESD & 340 ESD
Stocked Colors

Sky Gray Light Gray

Dark Gray Medium Gray

Special Order Colors

Grey White Beige

Black

The above are for use with Sikafloor® 200 ESD and Sikafloor® 340 ESD only. Sikafloor® 340 ESD is not available in
Dark Gray. Please consult Sika Industrial Flooring for further information and pricing. Because of the limitations of
process color printing, the color samples contained herein are close approximations of actual colors and should not be
relied upon for true color. Final color matching should be made with an actual sample of the product, color and texture
to be used. Custom colors are available. Our most current local Sales Conditions shall apply. Please consult the most
current local Product Data Sheet prior to any use.
COLOR SELECTION GUIDE FOR
SIKAFLOORS 260 ESD & 270 ESD

Sparrow Gray Richmond Gray Steel Gray

Anthracite Gray Blackstone Black Smokey Brown

Cyan Blue Tea Green Brickyard Red

The above are for use with Sikafloor® 260 ESD and Sikafloor® 270 ESD only. Please consult Sika Industrial Flooring
for further information and pricing. Because of the limitations of process color printing, the color samples contained
herein are close approximations of actual colors and should not be relied upon for true color. Final color matching
should be made with an actual sample of the product, color and texture to be used. Custom colors are available. Our
most current local Sales Conditions shall apply. Please consult the most current local Product Data Sheet prior to any
use.
COLOR SELECTION GUIDE FOR
SIKAFLOOR 264 ECF

SILVER GRAY LIGHT GRAY OXFORD GRAY

WINDOW GRAY TRAFFIC GRAY BEIGE ROSE

GRAY BEIGE SIGNAL YELLOW JET BLACK

RAFFIA BEIGE BEIGE TAN 251

BASALT GRAY TRAFFIC BLUE PALE GREEN

OXIDE RED TRAFFIC RED SIGNAL WHITE

The above are for use with Sikafloor® 264 ECF only. Please consult Sika Industrial Flooring for further information
and pricing. Because of the limitations of process color printing, the color samples contained herein are close
approximations of actual colors and should not be relied upon for true color. Final color matching should be made with
an actual sample of the product, color and texture to be used. Custom colors are available. Our most current local
Sales Conditions shall apply. Please consult the most current local Product Data Sheet prior to any use.
GLOBAL Sikafloor® ESD SOLUTIONS
SOLUTIONS FOR THE MARKETS IN EMEA
DIN EN 1081 IEC 61340-5-1 IEC 61340-5-1 IEC 61340-5-1 ATEX 137/TRBS 2153 DIN VDE 0100-410
Resistance to Ground (IEC 61340-4-5) (IEC 61340-4-1) (IEC 61340-4-1) European Standard (IEC 60364-4-1)
Rg <1 x 108 Ω System Test: Walking Test (BVG) Resistance to Ground Resistance to Ground Isolation Resistance
<1 x 109 Ω <100 Volt RG <1 x 109 Ω RG <1 x 109 Ω >50k Ω

Smooth and textured hygienic ECF floors


Sikafloor 262 AS N ́ * * ́ ́

Sikafloor 262 AS Thixo ́ * * ́ ́

Sikafloor 3240 ECF ́ * * ́ ́


High chemical resistance
Sikafloor 381 ECF ́ * * ́ ́ Any insulating,
self-smoothing
Sikafloor 390 ECF ́ * * ́ ́ layers e.g.
Approved for clean rooms Sikafloor 263 SL

Sikafloor 269 ECF CR ́ * * ́ ́


Food and Pharma Industry
Sikafloor 25 PurCem ECF ́ * * ́ ́
ESD systems with very low body voltage generation
Sikafloor 235 ESD ́ ́ ́ ́ ́
Sikafloor 262 AS N +
Sikafloor 305 W ESD ́ ́ ́ ́ ́

Sikafloor 236 SL/326


Sikafloor 305 W ESD ́ ́ ́ ́ ́
́
́ Meets the requirements
* Doesn’t meet the requirements

SOLUTIONS FOR THE MARKETS IN APAC


Smooth hygienic floors
Sikafloor 262 AS N ́ * * * ́

Sikafloor 239 EDF * ́ * ́ ́


High chemical resistance
Sikafloor 390 AS ́ * * * ́

Sikafloor 381 AS ́ * * * ́
ESD system with very low body voltage generation
Sikafloor 235 ESD * * ́ ́ ́
Sikafloor 262 AS N +
Sikafloor 305 W ESD * * ́ ́ ́

́ Meets the requirements


* Doesn’t meet the requirements
A GLOBAL AND LOCAL PARTNERSHIP

WE ARE SIKA
Sika is a specialty chemicals company with a leading position in the ­development and production of systems and products for bonding,
­sealing, damping, reinforcing and protecting in the building sector and the motor vehicle industry. Sika’s product lines feature concrete
admixtures, mortars, sealants and adhesives, structural strengthening systems, industrial flooring as well as roofing and waterproofing
systems.

© Copyright 2023 Sika Corporation / 05.5003.5/04/2023

UTION
SOL
LE
AB
A S U STA I N

M PLIA NT
CO

®
1

N
ISO 9001 LEED T IO
Certificate # FM 69711
V4 OP
RC 14001
Certificate # RC 510999

Sika Corporation • Flooring


201 Polito Avenue
Lyndhurst NJ 07071
Tel: 800 933 7452
www.SikaFloorUSA.com