U Value

Chapter 5 outlines the building envelope requirements for different climate zones, detailing maximum U-values and minimum R-values for various building assemblies including roofs, walls, floors, and fenestration. The document specifies requirements for nonresidential, residential, and semiconditioned buildings across three climate zones. It includes specific values for insulation types and performance metrics to ensure energy efficiency in building designs.

Uploaded by

kentmadarek
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
76 views3 pages

U Value

Chapter 5 outlines the building envelope requirements for different climate zones, detailing maximum U-values and minimum R-values for various building assemblies including roofs, walls, floors, and fenestration. The document specifies requirements for nonresidential, residential, and semiconditioned buildings across three climate zones. It includes specific values for insulation types and performance metrics to ensure energy efficiency in building designs.

Uploaded by

kentmadarek
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

CHAPTER 5 BUILDING ENVELOPE REQUIREMENTS

TABLE 5.1 Building Envelope Requirements for Climate Zone 1 SI


Nonresidential Residential Semiconditioned
Assembly Insulation Assembly Insulation Assembly Insulation
Opaque Elements Max U-Value Min R-Value Max U-Value Min R-Value Max U-Value Min R-Value
W/m2·°C m2·°C/W W/m2·°C m2·°C/W W/m2·°C m2·°C/W
Roofs
Insulation Entirely above Deck U-0.357 R-2.66 c.i U-0.272 R-3.54 c.i U-1.250 R-0.67 c.i
Metal Buildings U-0.369 R-2.57 c.i. U-0.369 R-2.57 c.i. U-0.950 R-0.92 c.i
Attic with Steel Joists U-0.193 R-6.91 U-0.153 R-9.70 U-0.460 R-2.27
Walls, Above-Grade
Mass U-1.191 R-0.60 c.i. U-0.312 R-2.96 c.i. U-1.191 R-0.60 c.i.
Metal Building U-0.193 R-5.04 c.i. U-0.193 R-5.04 c.i. U-0.233 R-4.14 c.i.
Steel-Framed U-0.255 R-3.42 c.i. U-0.255 R-3.42 c.i. U-0.738 R-0.86 c.i.
Walls, Below-Grade
Below-Grade Wall C-1.305 R-0.62 c.i. C-1.305 R-0.62 c.i. C-1.305 R-0.62 c.i.
Floors
Mass U-0.397 R-1.97 c.i. U-0.397 R-1.97 c.i. U-0.397 R-1.97 c.i.
Steel-Joist U-0.408 R-1.94 c.i. U-0.408 R-1.94 c.i. U-0.408 R-1.94 c.i.
Slab-On-Grade Floors
Unconditioned F-0.727 R-1.18 f.i. F-0.727 R-1.18 f.i. F-0.727 R-1.18 f.i.
Opaque Doors
Swinging U-2.84 U-2.84 U-2.84
Nonswinging U-5.9 U-5.90 U-5.90
Assembly Assembly Max. Assembly Assembly Max. Assembly Assembly Max.
Fenestration Max U-Value SHGC Max U-Value SHGC Max U-Value SHGC
W/m2·°C W/m2·°C W/m2·°C
Vertical Glazing, 0% to 40% of Wall
Nonmetal framing (all) U-2.89 U-2.89 U-2.89
Metal framing U-2.89 U-2.89 U-2.89
(curtainwall/storefront)d 0.25 0.25 NR
Metal framing U-2.89 U-2.89 U-2.89
Metal framing (all other) U-2.89 U-2.89 U-2.89
Vertical Glazing, >40% to 50% of Wall
Nonmetal framing (all) U-2.38 U-2.38 U-2.38
Metal framing U-2.38 U-2.38 U-2.38
(curtainwall/storefront)d 0.25 0.25 NR
Metal framing U-2.38 U-2.38 U-2.38
Metal framing (all other) U-2.38 U-2.38 U-2.38
Vertical Glazing, >50% to 100% of Wall
Nonmetal framing U-1.87 U-1.87 U-1.87
Metal framing U-1.87 U-1.87 U-1.87
(curtainwall/storefront)d 0.25 0.25 NR
Metal framing (entrance door) U-1.87 U-1.87 U-1.87
Metal framing (all other) U-1.87 U-1.87 U-1.87
Skylight with Curb, Glass, % of Roof
0%–2.0% U-11.23 0.36 U-11.23 0.19 U-11.23
NR
2.1%–5.0% U-11.23 0.19 U-11.23 0.16 U-11.23
Skylight with Curb, Plastic, % of Roof
0%–2.0% U-10.78 0.34 U-10.78 0.27 U-10.78
NR
2.1%–5.0% U-10.78 0.27 U-10.78 0.27 U-10.78
Skylight without Curb, All, % of Roof
0%–2.0% U-7.72 0.36 U-7.72 0.19 U-7.72
NR
2.1%–5.0% U-7.72 0.19 U-7.72 0.19 U-7.72
c.i. = continuous insulation
f.i. = fully insulated

SBC 601-CR-18 18
CHAPTER 5 BUILDING ENVELOPE REQUIREMENTS

TABLE 5.1 Building Envelope Requirements for Climate Zone 2 SI


Nonresidential Residential Semiconditioned
Assembly Insulation Assembly Insulation Assembly Insulation
Opaque Elements Max U-Value Min R-Value Max U-Value Min R-Value Max U-Value Min R-Value
W/m2·°C m2·°C/W W/m2·°C m2·°C/W W/m2·°C m2·°C/W
Roofs
Insulation Entirely above Deck U-0.454 R-2.06 c.i. U-0.34 R-2.80 c.i. U-1.590 R-0.49 c.i.
Metal Buildings U-0.471 R-1.99 c.i. U-0.47 R-1.99 c.i. U-1.135 R-0.74 c.i.
Attic with Steel Joists U-0.244 R-5.00 U-0.19 R-6.91 U-0.579 R-1.73
Walls, Above-Grade
Mass U-1.362 R-0.49 c.i. U-0.352 R-2.61 c.i. U-1.362 R-0.49 c.i.
Metal Building U-0.216 R-4.49 c.i. U-0.216 R-4.49 c.i. U-0.267 R-3.59 c.i.
Steel-Framed U-0.284 R-3.03 c.i. U-0.284 R-3.03 c.i. U-0.851 R-0.67 c.i.
Walls, Below-Grade
Below-Grade Wall C-1.305 R-0.62 c.i. C-1.305 R-0.62 c.i. C-1.305 R-0.62 c.i.
Floors
Mass U-0.567 R-1.22 c.i. U-0.567 R-1.22 c.i. U-0.567 R-1.22 c.i.
Steel-Joist U-0.624 R-1.09 c.i. U-0.624 R-1.09 c.i. U-0.624 R-1.09 c.i.
Slab-On-Grade Floors
Unconditioned F-0.727 R-1.18 f.i. F-0.727 R-1.18 f.i. F-0.727 R-1.18 f.i.
Opaque Doors
Swinging U-2.84 U-2.84 U-2.84
Nonswinging U-5.90 U-5.90 U-5.90

Assembly Assembly Max. Assembly Assembly Max. Assembly Assembly Max.


Fenestration Max U-Value SHGC Max U-Value SHGC Max U-Value SHGC
W/m2·°C W/m2·°C W/m2·°C
Vertical Glazing, 0% to 40% of Wall
Nonmetal framing (all) U-2.89 U-2.89 U-2.89
Metal framing U-2.89 U-2.89 U-2.89
(curtainwall/storefront)d 0.25 0.25 NR
Metal framing (entrance door) U-2.89 U-2.89 U-2.89
Metal framing (all other) U-2.89 U-2.89 U-2.89
Vertical Glazing, >40% to 50% of Wall
Nonmetal framing (all) U-2.38 U-2.38 U-2.38
Metal framing U-2.38 U-2.38 U-2.38
(curtainwall/storefront)d 0.25 0.25 NR
Metal framing (entrance door) U-2.38 U-2.38 U-2.38
Metal framing (all other) U-2.38 U-2.38 U-2.38
Vertical Glazing, >50% to 100% of Wall
Nonmetal framing (all) U-1.87 U-1.87 U-1.87
Metal framing U-1.87 U-1.87 U-1.87
(curtainwall/storefront)d 0.25 0.25 NR
Metal framing (entrance door) U-1.87 U-1.87 U-1.87
Metal framing (all other) U-1.87 U-1.87 U-1.87
Skylight with Curb, Glass, % of Roof
0%–2.0% U-11.23 0.36 U-11.23 0.19 U-11.23
NR
2.1%–5.0% U-11.23 0.19 U-11.23 0.16 U-11.23
Skylight with Curb, Plastic, % of Roof
0%–2.0% U-10.78 0.34 U-10.78 0.27 U-10.78
NR
2.1%–5.0% U-10.78 0.27 U-10.78 0.27 U-10.78
Skylight without Curb, All, % of Roof
0%–2.0% U-7.72 0.36 U-7.72 0.19 U-7.72
NR
2.1%–5.0% U-7.72 0.19 U-7.72 0.19 U-7.72
c.i. = continuous insulation
f.i. = fully insulated

SBC 601-CR-18 19
CHAPTER 5 BUILDING ENVELOPE REQUIREMENTS

TABLE 5.1 Building Envelope Requirements for Climate Zone 3 SI


Nonresidential Residential Semiconditioned
Assembly Insulation Assembly Insulation Assembly Insulation
Opaque Elements Max U-Value Min R-Value Max U-Value Min R-Value Max U-Value Min R-Value
W/m2·°C m2·°C/W W/m2·°C m2·°C/W W/m 2·°C m2·°C/W
Roofs
Insulation Entirely above Deck U-0.511 R-1.81 c.i. U-0.397 R-2.38 c.i. U-1.759 R-0.42 c.i.
Metal Buildings U-0.528 R-1.76 c.i. U-0.528 R-1.76 c.i. U-1.362 R-0.60 c.i.
Attic with Steel Joists U-0.272 R-4.40 U-0.216 R-5.96 U-0.647 R-1.50
Walls, Above-Grade
Mass U-1.588 R-0.39 c.i. U-0.414 R-2.17 c.i U-1.588 R-0.39 c.i.
Metal Building U-0.255 R-3.77 c.i. U-0.255 R-3.77 c.i. U-0.312 R-3.05 c.i.
Steel-Framed U-0.340 R-2.43 c.i. U-0.340 R-2.43 c.i. U-0.964 R-0.53 c.i.
Walls, Below-Grade
Below-Grade Wall C-1.305 R-0.62 c.i. C-1.305 R-0.62 c.i. C-1.305 R-0.62 c.i.
Floors
Mass U-0.567 R-1.22 c.i. U-0.567 R-1.22 c.i. U-0.567 R-1.22 c.i.
Steel-Joist U-0.624 R-1.09 c.i. U-0.624 R-1.09 c.i. U-0.624 R-1.09 c.i.
Slab-On-Grade Floors
Unconditioned F-0.727 R-1.18 f.i. F-0.727 R-1.18 f.i. F-0.727 R-1.18 f.i.
Opaque Doors
Swinging U-2.84 U-2.84 U-2.84
Nonswinging U-5.90 U-5.90 U-5.90

Assembly Assembly Max. Assembly Assembly Max. Assembly Assembly Max.


Fenestration Max U-Value SHGC Max U-Value SHGC Max U-Value SHGC
W/m2·°C W/m2·°C W/m 2·°C
Vertical Glazing, 0% to 40% of Wall
Nonmetal framing (all) U-2.89 U-2.89 U-2.89
Metal framing U-2.89 U-2.89 U-2.89
(curtainwall/storefront)d 0.25 0.25 NR
Metal framing (entrance door) U-2.89 U-2.89 U-2.89
Metal framing (all other) U-2.89 U-2.89 U-2.89
Vertical Glazing, >40% to 50% of Wall
Nonmetal framing (all) U-2.38 U-2.38 U-2.38
Metal framing U-2.38 U-2.38 U-2.38
(curtainwall/storefront)d 0.25 0.25 NR
Metal framing (entrance door) U-2.38 U-2.38 U-2.38
Metal framing (all other) U-2.38 U-2.38 U-2.38
Vertical Glazing, >50% to 100% of Wall
Nonmetal framing (all) U-1.87 U-1.87 U-1.87
Metal framing U-1.87 U-1.87 U-1.87
(curtainwall/storefront)d 0.25 0.25 NR
Metal framing (entrance door) U-1.87 U-1.87 U-1.87
Metal framing (all other) U-1.87 U-1.87 U-1.87
Skylight with Curb, Glass, % of Roof
0%–2.0% U-11.23 0.36 U-11.23 0.19 U-11.23
NR
2.1%–5.0% U-11.23 0.19 U-11.23 0.16 U-11.23
Skylight with Curb, Plastic, % of Roof
0%–2.0% U-10.78 0.34 U-10.78 0.27 U-10.78
NR
2.1%–5.0% U-10.78 0.27 U-10.78 0.27 U-10.78
Skylight without Curb, All, % of Roof
0%–2.0% U-7.72 0.36 U-7.72 0.19 U-7.72
NR
2.1%–5.0% U-7.72 0.19 U-7.72 0.19 U-7.72
c.i. = continuous insulation
f.i. = fully insulated

SBC 601-CR-18 20