Le23m934 e LW DG 502 4009
Le23m934 e LW DG 502 4009
7 6 5 4 3 2 1
B
MA
IN
GA
TE
4M
FEN
WID
(TY G
W1 EF PPR
CIN
N:2 33258
OA
E:2
S1
CH
P)
D RO
312
AD
346 28
(CHARGED AT 6.6kV)
blo ust
.8
.79
thr
ck
4
(OUTDOOR AREA) 23 24 25
900IPE
(ty b
(REFER SHEET - 03) 19 20
DJ
BFV
P
p)
n
SS-2
4M RS
5M WIDT
SS-2
PT
SAN
HEIG H x
FIT
TO
EB
HT MA
INT
SS-2
BFV
EN
EB
PRESSURE FILTER
ARO
BA ANCE
BFV
Y
as-1
21
DJ BF
DPCV
HIL
as-1
DJ
900 E
(ty b
DPCV
as-1
V
A
BFV
PIP
VALAIR
p ) BO
n
SS-1
500 E
VE
(ty b
SS-1
PIP
600 E
p)
(ty b
n
OS
PUM R PRES
nrv SS-1
PIP
p)
DJ
n
FIL ARY
TE
PRIM
BFV nrv
EB DJ
P
SS-1
TER
BFV nrv
EB DJ
SS-1 BFV
EB
SS-1
FIL URE
VT-1
S
T ER
VT-2
11KV
VT-3
PLC
RO FO
BOOSTER PUMP 2Nos OF 40NB GI PIPE O M S UR
(CH TRUC POLE
SEC
AR T
GE URE
D
CONCEALED IN SLAB 6.6 AT
CA Y
VT-03 VT-02 VT-01
URIT
ELE KV)
CT
BIN
RIC
AL
RO
OM
THIS AREA
PIP INT
1.5
RC
N:2 33270
M X GATE
E 12 AKE
E:2
C
CABLE CELLAR ROOM TA
312
SLU
NS
00N
1.5
FO
RM
348.678
WIT EVEL
ER
ICE
M
B
L
.65
H 10 TRA
P.F.L
CLA NB ANSMIT
3
0
SS
150 I B16.5R
N
FLA CED
S
FA
W1
NG
TE
E
BFV BFV BFV
A
13
27
C PRIMARY FILTRATION
1:100
0
SLOP
D1 EF EF 28 SYSTEM
E
29
N:2 33415
E:2
22
312
295 79
.5
UP
.913
18
KEY PLAN
UP
NOTES:
14 PUMP HOUSE 1. ALL DIMENSIONS ARE IN MM & LEVELS ARE IN METER UNLESS OTHERWISE SPECIFIED.
B
P.F.L
B 26
2. ALL PANELS SHOWN IN THE DRAWING WILL HAVE BOTTOM CABLE ENTRY.
3. FOR DIMENSIONS OF COLUMN, WALLS, SLABS & BEAMS REFER CIVIL DRAWING.
4. LEVELS AND OTHER SECTIONAL ELEVATIONS SHALL BE AS PER CIVIL DRAWING.
A 5. FOR EXACT LOCATION OF DOORS, WINDOWS, VENTILATIONS & CUTOUTS REFER CIVIL DRAWING.
6. CABLE TRAYS AND CABLE TRENCH SHOWN ARE INDICATIVE ONLY. CABLE ROUTING LAYOUT SHALL BE SUBMITTED SEPARATELY.
7. INDIVIDUAL EQUIPMENT DIMENSION INDICATED ARE TENTATIVE ONLY. HOWEVER ACTUAL DIMENSION SHALL BE UPDATED ON
A
RECEIPT OF VENDOR DRAWINGS.
8. OPEN VENTILATION IS NOT CONSIDERED IN ELECTRICAL ROOM.
9. PANEL BOTTOM FRAME SHALL BE MATCHED WITH THE ELECTRICAL ROOM FINISHED FLOOR LEVEL AND THERE SHALL NOT BE
ANY GAP EITHER IN VERTICAL OR HORIZONTAL FACES OF THE BOTTOM OF THE PANEL.
9. ALL THE OPEN FLOOR CUTOUTS SHALL BE COVERED BY CHEQUERED PLATE AFTER PLACEMENT OF PANELS.
10. EARTHING AND LIGHTNING PROTECTION LAYOUT SHALL BE SUBMITTED SEPARATELY.
11. RUBBER MAT SHALL BE PROVIDED IN FRONT OF PANELS AS PER IS-15652 (2006).
12. CONTROL ROOM LAYOUT FOR PUMPING STATION DETAILS SHALL BE SUBMITTED SEPARATELY VIA DOCUMENT NO.
LE23M934-I-LW-WS-502-CR-5006.
13. ROOF TOP SOLAR PANEL ARRANGEMENT SHALL BE AS PER VENDOR DOCUMENT.
14. REFER SHEET 2 FOR SWITCHGEAR ROOM EQUIPMENT LAYOUT PLAN, SECTION, CUTOUT DETAILS & EQUIPMENT DIMENSION.
15. REFER SHEET 3 FOR DSS DETAIL DRAWINGS.
REFERENCE DRAWINGS:-
3 2 1
S.NO. DESCRIPTION DOCUMENT NO.
SOLAR PANEL
OVERALL SINGLE LINE DIAGRAM FOR SANA ROHILA
01. LE23M934-E-LW-1L-502-4001
(ID NO-502) PUMP HOUSE
GENERAL ARRANGEMENT OF PUMP HOUSE
02. LE23M934-M-LW-WS-GA-2003
7 6 5 4 FOR SANA ROHILA
11KV FOUR POLE
STRUCTURE
(REFER SHEET-03)
PUMP HOUSE
WF WF
12.5T EOT CRANE
ELECTRICAL SWITCHGEAR ROOM PLC CONTROL
ROOM A FOR APPROVAL
NK/RP 22.08.24 NGP 22.08.24 AKKS 22.08.24 GK 22.08.24
16
10 REV.NO. DESCRIPTION DESIGNED DRAWN CHECKED APPROVED
01
VT-03 VT-02 VT-01
02 03 04 REVISIONS
E.F.L PRIMARY FILTRATION
P.F.L+3.000 SYSTEM CLIENT : DEPARTMENT OF WATER RESOURCES, ODISHA
B.O.B
PROJECT DIRECTOR-CUM-CHIEF ENGINEER, PMU, MEGALIFT PROJECTS
27
PROJECT : MEGA LIFT IRRIGATION PROJECT - CLUSTER XXII
EL(+)121.550
F.Gr.L
EL(+)121.500
QR CODE
EL(+)121.450
T.O.C P.F.L
CONTRACTOR:
L&T Construction
Water & Effluent Treatment IC
7 6 5 4 3 7 6 5 4 3
100(L)x100(W)
B B FLOOR OPENING
(TYP)
V1
W3
W3
01 02 03 04
12
PLC CONTROL ELECTRICAL SWITCHGEAR ROOM PLC CONTROL
ELECTRICAL SWITCHGEAR ROOM DD2
10 ROOM E.F.L DD2 ROOM
E.F.L
A A A EDGE ANGLE ISA 100X100X8 AROUND FLOOR CUTOUT A
11 CORNERS OF CUTOUT(TYP) (TYP)
W3
W3
05 06 08 07 09 100(L)x100(W)
W1/V1
W1/V1
FLOOR OPENING
15
DD1 DD3 DD1 DD3
SD1 C SD1 C
W1/EF W1/V1 W1/EF W1/V1
CAGE CAGE
LADDER LADDER
LANDING LANDING
HAND RAIL HAND RAIL
PLATFORM UP PLATFORM UP
UP UP
REMOVABLE REMOVABLE
HAND RAIL HAND RAIL
B B
3 TON MONO RAIL 3 TON MONO RAIL
FOR CHAIN FOR CHAIN
PULLEY BLOCK B PULLEY BLOCK B
17 ELECTRICAL SWITCHGEAR ROOM VENTILATION FAN STARTER PANEL-3 SWITCHGEAR ROOM 400x200x400 T
13
18 PUMP HOUSE VENTILATION FAN STARTER PANEL-1 PUMP HOUSE 400x200x400 T
CABLE CELLAR
A FOR APPROVAL
EL(+)121.500
ROOM 19 PUMP HOUSE VENTILATION FAN STARTER PANEL-2 PUMP HOUSE 400x200x400 T NK/RP 22.08.24 NGP 22.08.24 AKKS 22.08.24 GK 22.08.24
P.F.L
20 PUMP HOUSE VENTILATION FAN STARTER PANEL-3 PUMP HOUSE 400x200x400 T REV.NO. DESCRIPTION DESIGNED DRAWN CHECKED APPROVED
21 PUMP HOUSE VENTILATION FAN STARTER PANEL-4 PUMP HOUSE 400x200x400 T REVISIONS
22 PUMP HOUSE VENTILATION FAN STARTER PANEL-5 PUMP HOUSE 400x200x400 T
CLIENT : DEPARTMENT OF WATER RESOURCES, ODISHA
23 DESILTING PUMP MOTOR ISOLATOR BOX-01 PUMP HOUSE 600x300x600 T
PROJECT DIRECTOR-CUM-CHIEF ENGINEER, PMU, MEGALIFT PROJECTS
24 FORCED WATER LUBRICATION BOOSTER PUMP-1 LOCAL CONTROL PANEL PUMP HOUSE 600x300x600 T
SECTION B-B
25 FORCED WATER LUBRICATION BOOSTER PUMP-2 LOCAL CONTROL PANEL PUMP HOUSE 600x300x600 T
PROJECT : MEGA LIFT IRRIGATION PROJECT - CLUSTER XXII
26 EOT CRANE ISOLATOR BOX PUMP HOUSE 300x250x400 T
QR CODE
27 LOCAL PUSH BUTTON STATION FOR VT PUMP MOTOR-1 PUMP HOUSE 250x200x350 T
CONTRACTOR:
L&T Construction
28 LOCAL PUSH BUTTON STATION FOR VT PUMP MOTOR-2 PUMP HOUSE 250x200x350 T
Water & Effluent Treatment IC
29 LOCAL PUSH BUTTON STATION FOR VT PUMP MOTOR-3 PUMP HOUSE 250x200x350 T
TRANSFORMER & DO
D 01 6kV, 10kA LIGHTING ARRESTER
℄ OF LA, AB SWITCH
3 Nos
4. CABLE ROUTING LAYOUT, EARTHING LAYOUT & DETAILS, LIGHTING & LIGHTNING
℄ OF STRUCTURE
℄ OF STRUCTURE
AIR BREAK SWITCH WITH EARTH SWITCH. PROTECTION LAYOUT SHALL BE SUBMITTED IN SEPARATE DRAWING.
02 1 Set
(DOUBLE BREAK) 7.2kV, 400A, 25kA FOR 3 SEC. 5. FOUNDATION LAYOUT WITH DETAILS OF CIVIL COMPONENTS FOR MAJOR EQUIPMENTS &
AUXILIARY
DO FUSE
DO FUSE
AIR BREAK SWITCH (DOUBLE BREAK) 7.2kV, STRUCTURES, FENCE DETAILS SHALL BE SUBMITTED IN SEPARATE DRAWING.
D 03
FUSE
400A, 25kA FOR 3 SEC. 2 Set
6. THE LAYOUT HAS BEEN PREPARED AS PER COMPATIBLE REC STANDARDS.
7. GALVANIZED STRUCTURES ARE OF 7.5M HEIGHT FROM PLINTH LEVEL.
04 100kVA, 6.6/0.433kV, AUXILIARY TRANSFORMER 1 No
8. AUXILIARY TRANSFORMER HAS BEEN SIZED BASED ON ACTUAL CALCULATED LOAD FOR
THE PUMP HOUSE.
05 7.2kV DROP OUT FUSE, 200A. (VERTICAL TYPE) 1 Set
9. TOP OF PLINTH SHALL BE 325MM ABOVE THE FGL.
CHAIN LINK FENCE (TYP) 11kV DISC POLYMER INSULATOR SET WITH GALVANIZED 10. THERE MAY BE RE-ORIENTATION OF LAYOUT BASED SITE CONDITION.
3 Nos
HARDWARE TO SUIT INCOMING OVERHEAD CONDUCTOR.
11. DUE CARE SHALL BE TAKEN TO ENSURE THAT THE CABLE TAKEN FROM DSS IS
06
W1
(Approx.)
℄ - CENTER LINE
℄ OF STRUCTURE & AB
SWITCH & AUX. B.O - BOTTOM OF
TRANSFORMER C.O - CENTER OF
SYSTEM CLEARANCES:
LEVELS:
MIN. CLEARANCE 11kV
C B Y R C F.F.L (FINISHED FLOOR LEVEL) EL(+)121.500
6.6kV INCOMING LINE 01 PHASE-PHASE CLEARANCE 200 mm
F.Gr.L (FINISHED GRAVEL LEVEL) EL(+)121.550
02 PHASE-EARTH CLEARANCE 180 mm
06 PHASE-PHASE 760 mm
07 PHASE-EARTH 740 mm
LIGHTNING SPIKE
G.I. PIPE 2.5M LONG
(TYP)
LIGHTNING
ARRESTOR
T-CONNECTOR
AB SWITCH WITH (SP-SP)(TYP)
EARTH SWITCH
ACSR PANTHER
T-CONNECTOR CONDUCTOR
B.O AB SWITCH WITH (SD-SP)
EARTH SWITCH LEVEL
C.O DISC INSULATOR 6.6kV INCOMING LINE
LEVEL FROM MSDSS
DO FUSE
C.O DO FUSE LEVEL PIPE CLAMPING
(TYP)
100kVA, 6.6/0.433kV
AUXILIARY TRANSFORMER
TRANSFORMER
BELT 100MM DIA
PIPE
P.F.L+3.000
B.O.B
C.O TRANSFORMER
LEVEL A FOR APPROVAL
NK/RP 22.08.24 NGP 22.08.24 AKKS 22.08.24 GK 22.08.24
CONTRACTOR:
L&T Construction
Water & Effluent Treatment IC
℄ OF AB SWITCH & DO
℄ OF AB SWITCH, DO
℄ OF STRUCTURE &
AB SWITCH & AUX.
℄ OF STRUCTURE
℄ OF STRUCTURE
NK/RP
AB SWITCH
FUSE