SUP 23T User Manual
SUP 23T User Manual
catalogue
1. Overview ....................................................................................................................1
     1.1 Operating environment and parameters ............................................................ 3
     1.2 Attention information ........................................................................................4
2. Installation and connection ........................................................................................ 4
     2.1 Controller interface definition .......................................................................... 4
          2.1.1 Power supply terminal of the controller ................................................. 7
          2.1.2 The LCD screen terminal of the controller ............................................. 7
          2.1.3 Controller signal interface 1 ................................................................... 7
          2.1.4 Controller signal interface 2 ................................................................... 8
          2.1.5 Controller signal interface 3 ................................................................... 9
     2.2 Terminal block diagram of the controller ....................................................... 10
     2.3 Optical fiber input interface ............................................................................10
     2.4 Protect the gas and the water cooler interface .................................................11
     2.5 Connecting interface between welding gun and control box ..........................11
3. Control panel operation guide ..................................................................................12
4. Maintenance .............................................................................................................22
5. Common exception handling ................................................................................... 28
     5.1 Warning of laser / water cooler / air pressure alarm ....................................... 28
     5.2 Screen not bright / click not responsive ..........................................................28
     5.3 No light ........................................................................................................... 29
     5.4 Suddenly stop producing light during processing ...........................................29
appendix .......................................................................................................................30
     Thank you for choosing the four-in-one system, and this user manual provides
you with important safety, operation, maintenance and other information. Therefore,
please read this user manual carefully before using this product.
    To ensure safe operation and optimal product performance, follow the following
precautions and warnings and other information in this manual.
1. Overview
     This manual covers the basic installation, factory setting, operation and
maintenance services of SUP series 23T model.
     SUP23T Four-in-one hand welding head is a new super great application in
handheld laser welding, non-contact welding, welding cleaning, cutting field of single
motor scanning swing welding head —— hereinafter referred to as SUP23T. The
product includes a handheld laser head and its control system, and has multiple safety
alarms and active safety light break settings. It is developed on the basis of the
SUP20T handheld laser head which has been mass produced by our company.
Compared with the previous generation, it is further improved in insulation, stability,
maintenance and other aspects, and has the characteristics of more compact, lighter
and more reliable.
    The product can be adapted to various brands of fiber lasers, optimized optical
and water cooling design so that the laser head can work stably for a long time at
3000W, and the cleaning width of switching cleaning mode is up to 120mm.
             Figure 1.1 Schematic diagram of the SUP-23T welding head
 Product features:
● Basic features of the product: self-developed control system and structural design,
adapt to various welding requirements within 3000W, set multiple safety alarms and
state indicator lights, abnormal state instantaneous response. The net weight of 750k
is flexible and easy to use.
● The whole machine is more stable: all parameters can be seen, monitor the state of
the whole machine in real time, avoid problems in advance, facilitate troubleshooting
and troubleshooting, and ensure the stable operation of the hand-held welding head.
● Subversion structure design: the main structure integrated design and processing,
greatly reduce the failure rate, and facilitate the later maintenance.
● Controlled parameters and high repeatability. Stable nozzle pressure and lens state,
as long as the laser power is stable, the process parameters must be repeated, save the
adjustment time, improve the work efficiency.
   As shown in Table 1.1, the operating environment requirements and main
parameters of SUP23T:
    Table 1.1 Operating environment requirements and main parameters of SUP23T
             input voltage (V)           220V±10% AC 50/60Hz
                Installation           Flat, no vibration and
                 environment                   impact
            Working environment
                                                 10~40
             temperature: (℃)
            Working environment
                                                  <70
               humidity: (%)
            cooling-down method              hydrocooling
                 Applicable
                                           1064nm(±10nm)
                 wavelength
              Applicable power                  ≤3000W
                  alignment                   D16*4.5/F60
                    focus                    D20*4.5/F150
                    reflex                      30x14xT2
             Protection mirror
                                                 D18*T2
               specifications
            Maximum air pressure
                                                 15Bar
                  support
             Focus of vertical
                                                 ±10mm
              adjustment range
               Scan width-weld                   0~8mm
                                              F150-0~30mm
               Scan Width-Wash                F400-0~60mm
                                             F800-0~120mm
            The net weight of the
                                                 0.75kg
                     gun
     (1) Ensure reliable grounding before power supply.
     (2) The laser output head is connected with the hand-held laser head through
 QBH, please carefully check the laser output head to prevent dust or other pollution.
 Please use special lens paper when cleaning the laser output head.
     (3) If the equipment is not used according to the method specified in the manual,
 it may be in an abnormal working state and lead to damage.
     (4) When replacing the protective mirror, please ensure good protection.
     (5) Please note: for the first time, when the red light can not come out of the
 copper mouth, be sure not to shine.
     (6) State indication: the gun body [state indicator light] is ①, red flashing
 indicates that the —— water cooler alarm, laser alarm, air pressure alarm, can not
 shine at this time.②, The red light indicates that the —— protection mirror over
 temperature alarm, the motor driver over temperature alarm, at this time the
 equipment is in an abnormal state can force light, should be stopped for inspection.
      The LCD screen wiring is randomly attached and connected directly. See
 Table 2.1 above for specific definition.
      Signal interface 1 uses 8P interface and is the input signal interface, and the
 detailed interface definition is shown in Table 2.2:
                              Signal interface 1
The pin
                  Signal definition                     function declaration
 number
  1                         GND                 For the pressure alarm signal
                                                    input port, if enabling
                                                   (wiring), please set the
  2         Air pressure alarm signal           "pressure alarm level" of the
                                                display setting page with the
                                                actual air valve alarm level.
  3                         GND                 Water tank alarm signal input
                                                  port. If you need to enable
  4           Water tank alarm signal            (wiring is required), please
                                                  set the "water cooler alarm
                                                  level" on the display setting
                                                  page consistent with the actual
                                                    water cooler alarm level.
                                                  When connecting the metal clip,
                      Safety ground lock           the system does not make the
     5
                        reference place              judgment, and the foot is
                                                             suspended
                                              Seven-core wire-blue wire
                                            (upper mark safety lock) -in
     6                Safety lock          cleaning mode, the system does
                                           not make a judgment, this foot
                                                     is suspended
                                           Seven-core-black line (marked
     7         Welding head light switch 1
                                                   light switch 1)
                                                    Seven-core-brown line (marked
     8         Welding head light switch 2
                                                          light switch 2)
Note: Note that normal output signal on the subsequent output port only
when there is no alarm and the safety lock and switch signal are displayed
                                 in green.
    Signal interface 2 uses the 6P interface, and the detailed functional definition is
shown in Table 2.3:
                                 Signal interface 2
 The pin
                Signal definition                     function declaration
  number
            Temperature measurement:          Control status indicator lamp to
    1
             1 / status indication                  form a loop with GND
            Temperature measurement          The protective mirror needs to form
    2
                       2                               a loop with GND
    3         Protection Gas Valve-            Air valve open: protection air
                                                     valve + output 24V;
    4        Protective gas valve +          Air valve is closed: protection air
                                                      valve + no output.
    5                wire feed-              Wire supply switch signal of wire
    6               wire feed +               feeder, wiring by wire standard.
    The signal interface 3 uses the 7P interface, and the detailed functional definition
is shown in Table 2.4:
                                   Signal interface 3
   The pin
                    Signal definition                    function declaration
   number
                                             To enable (wiring), set the "laser alarm
                      Laser abnormal
        1                                  level" of the display setting page consistent
                          signal
                                             with the alarm level of the actual laser.
                     The laser enables     Enabling +, connected to the laser enabling
        2
                           light                               +.
                                              24V output, power directly output 24V
        3                24V output
                                                            voltage.
                                           Common ground (reference ground for foot
        4                  GND
                                                       1 / 2 / 3 / 5)
                                           Analog output (the default is 0-10 V analog
        5           analog quantity +
                                                            voltage).
        6                RF- (PWM-)                     PWM-modulating signal
        7            RF + (PWM +)                   PWM+ modulating signal
   Note: Both the ± 15V switching power supply COM end and the
+ 24V switching power supply-V (0V) end should be connected to the
GND. The switching power supply shell must be connected to the
earth, otherwise there may be no light and other abnormalities.
    SUP welding head is suitable for the vast majority of industrial laser generators,
commonly used optical fiber joints including IPG, Ruike, Chuangxin, Feibo, Spurs,
Jept, Kaplin, etc. The optics must be kept clean, all dust must be removed before use,
and the torch head must be placed horizontally to prevent dust from falling into the
interface.
method of erection
    The water pipe and gas pipe interface can be installed with a hose with outer
diameter 6mm inner diameter 4mm. Access and exit pipeline of waterway (regardless
of entry and exit direction)
The cooling system is divided into waterway section of welding head and waterway
section of optical fiber head connected in series as shown in the following figure:
Figure 2.2 Water route diagram of welding head and optical fiber head
The handheld welding head is connected to the control box through a group of
"multi-function system connecting lines". The handheld welding head end is the
aviation plug female head, and the control box head end is the aviation plug male
head. The seven-core wire connecting gun body controls the light and temperature
monitoring, and the two-core and five-core wires are the vibrator motor control line.
3.      The Control Panel Operating Guide
      SUP-23T handheld welding head control panel version number is V5.8-802-801,
the version number is subject to the physical picture for reference only.
     Supported languages: 19 languages.
 Simplified Chinese          English                Korean                  Russian
Traditional Chinese         Japanese                Dervin                  French
       Italian               Spanish              Portuguese                Turkish
       Greek                  Czech                 Slovak                  polish
        Thai                Vietnam                 Romania
Table 1
     1. Welding mode
                Figure 3.1-1, the front page of the control panel
    ① This interface can see the current process parameters (this page can not be
modified process) and real-time alarm information.
    ② The default is ON, the red light is LINE by default, and the welding mode is
continuous. When the enabling is turned off, the enabling signal will not be sent to the
laser and can be used to test the outlet function. Close the red light indicator, the
motor stops swinging, and the red light is a point to adjust the center position. The
welding mode is divided into continuous and spot welding. When the spot welding is
selected, the spot welding type needs to be set on the setting page.
    ③ The safety lock is divided into gray and green. When the metal clip is
clamped on the processing piece and the copper nozzle of the gun contacts the
processing piece, the 5 and 6 feet of the signal interface 1 are connected, and the
safety lock indicator is displayed as green. At this time, the light can be realized
according to the trigger.
        ④ Click on the upper right corner to switch to the cleaning mode.
    The current process page provides 10 process items for users to save
parameters. The definition and scope of process parameters are described below:
                    Figure 3.1-2 Control panel process page
click the box (red) to modify, click OK, and then save in the quick process,
② The scan speed range is 2-6000mm / S, and the scan width range is 0 ^ 6mm. The
scan speed is limited by the scan width, which is: 10 scan speed / (scan width * 2)
1000 If the limit is exceeded, it automatically becomes the limit value. When the
scan width is set to 0, it does not scan (ie, a point light source)
(The most commonly used scanning speed: 300mm / S, width of 2.5-4mm).
③ The peak power should be less than or equal to the laser power of the parameter
page (if the laser power is 1000W, this value is not higher than 1000).
⑥ Click the HELP button on the top right to get more relevant parameter
explanations.
⑦ After modifying the parameters, you can see whether the import is successful on
the home page
                               graph 3.1-4
   Generally preset switch light power 20%, switch light step time 200ms;
   ④ Silk delay compensation is the advance time relative to the light
signal, which can be used with the withdrawal function, not set by default;
   ⑤ The maximum value of the three temperature alarm valves is 70℃.
When the value is set to 0, the temperature is not detected, and the buzzer
alarms when the measured temperature is greater than the set value;
   ⑥ Scan correction coefficient = target line width / measured line
width, range from 0.01 to 4. Generally set to 1;
   ⑦ Laser center offset-3~3mm, decrease to the left, increase to the
right, applied to adjust the red axis light center;
   ⑧ Air pressure / water cooler / laser alarm level signal is low level,
and when this alarm signal is used, the alarm level here should be set
to the same with the alarm level of external equipment;
   ⑨ The spot welding duration is the light output time in each cycle
in the spot welding mode, and the spot welding interval time is the light
stop time in each cycle in the spot welding mode;
   ⑩ Click on the Help button at the top right to get more relevant
parameter explanations.
                                   graph 3.2-1
    [Scan width] is set to [0], which refers to the [copper mouth] for replacing
cutting, which can be cut.[safe ground lock] needs to be ensured.
    3. Cleaning mode
                                   graph 3.3-1
    ① This interface can see the current process parameters (this page can not be
modified process) and real-time alarm information.
    ② The default state is ON, indicating that the red light is LINE by default. When
the enabling is turned off, the enabling signal will not be sent to the laser and can be
used to test the outlet function. Close the red light indicator, the motor stops swinging,
and the red light is a point to adjust the center position.
    ③ Click on the upper right corner to switch to the cleaning mode.
                                       graph 3.3-2
    ① The process interface contains the process parameters of debugging, click the
box (red) to modify, click OK, and then save in the quick process, click import
(modify-save-import).
    ② The scan frequency range is 10-100 HZ, and the scan width range is 0 ^
30mm.
    (At the focusing lens F800, the maximum width is 130mm. At the focusing mirror
F150, the maximum width is 30mm).
    ③ Peak power should be less than or equal to the parameter page laser power.
    (If the laser power is 1000W, then this value is not higher than 1000).
    ④ Duty cycle range 0 to 100 (default 100, usually not changed).
    ⑤ The pulse frequency range is recommended from 5-5000Hz (default 2000,
usually no modification).
    ⑥ Click the "Help" button on the top right to get more relevant parameters
explained.
    ⑦ After modifying the parameters, you can see whether the import is successful
on the home page.
    ⑧ Reference process, can be used in the small program process reference.
                                    graph 3.3-3
     Password: 123456
    ① The laser power is the power of the used laser, please fill in correctly.
    ② The default gas delay default 200ms, range 200ms-3000ms.
    ③ From N1% of process power to 100%; from 100% of process power to N2;
(as shown in the figure below).
                                     graph 3.3-4
  The higher the process power, the lower the recommended open light power. Open
light power usually should not exceed 50%, too high open light power will greatly
reduce the service life of the lens.
④ The maximum temperature alarm valve value is 65℃. When the value is set to 0,
the temperature alarm is not detected.
⑤ Scan correction coefficient range 0.01~4, coefficient target line width / measured
line width: the default is 1.0.
⑥ Laser center offset: The cleaning mode only shows the current offset. If you need
to adjust the center, please cut back to the welding mode, and replace the F150
aggregation mirror to ensure accuracy.
⑦ The pressure / water cooler / laser alarm level signal is low level by default. When
this alarm signal is used, if the external pressure alarm is installed, it will be changed
to high level, otherwise there will be abnormal alarm will occur, and other alarm
signals should be the same.
⑧ Click the "Language" button, you can switch to other languages in the language
selection bar. Currently, the standard version supports 19 languages. Please contact us
if necessary.
                                     graph 3.3-5
⑨ Click "Help" in the upper right corner to enter the help page of the Settings page.
Long press "Restore factory Settings" to restore the setting parameters to the factory
state. Long press "Save as factory settings" to modify the factory parameters.
                                     graph 3.3-6
⑩ Click "Gun size number" to focus the mirror to select the maximum scanning
width.
                                     graph 3.4-1
This page displays the status of each signal and the equipment information
Laser trigger signal: when the trigger is pulled, this state changes from gray to green
Laser / water cooler / air pressure alarm signal: monitor its set high and low levels
The output signal is shown in the middle of the page, colored green when the signal is
output
Equipment authorization: the equipment can be authorized, when the equipment is
used over the set time, the authorization shall be terminated,
System version: three groups of numbers, the first group is the hardware version, the
second group is the microcontroller program version, the third group is the touch
screen version
                                     graph 3.4-2
Click the Diagnostic-button to enter the diagnostic page. Under this page, the laser
will not emit light, you can control the independent output "PWM", "laser enabling",
"air valve enabling" and "analog amount" through the "switch control", and compare
the detection value to judge the theoretical value of the control box function is
normal.
    4. Welding seam cleaning
  Change the [AS-2.0D] copper nozzle in welding mode. For the specific process, see
the wechat small program demonstration video
4. Maintenance
     Maintenance and replacement method of related lenses:
    ① Before the operation, please clean your hands and dry them first, and then
wipe your hands again with cotton dipped in alcohol.
    ② Open the protective mirror in a relatively dust-free place, focus the mirror
compartment cover, pull out the lens bracket, do a good job of protection (beautiful
paper cover), check the protective lens, if there is an obvious burning point on the lens
surface, should be directly replaced.
    ③ Then check the white storage seal ring under the lens.(If the storage sealing
ring cannot be used, it must be replaced immediately.
    ④ Wipe the warehouse mouth and the inside of the warehouse cover with a
cotton ball dipped in alcohol, quickly insert the protective lens bracket into the
protective mirror compartment, and lock the screws.
    ① If the above alarm does not using the alarm signal, please change the alarm
level of screen setting page.
    ② If the alarm appears in the above alarm signal, check whether the alarm or the
high and low level of the alarm signal is set correctly.
    ① The screen is not bright, make sure the controller is powered on. Check
whether the controller and the four-core wire of the screen are connected correctly,
and whether the voltage of foot 1 and 4th foot 24V is normal.
    ② If not clicked in normal use, check whether the temperature of the machine is
too high.
    ③ Click unable to input, check whether the wiring between the controller and
the screen is correct, and whether the second and third feet are normal. See 2.1.2
controller display end for details.
    ④ Newly installed equipment click no reaction may be the system version does
not match, use the SD card to rebrush the program can be, please ask us for the
specific version.
    ① Check whether there is an alarm prompt on the home page, and whether the
laser enabling system is ON;
    ② Check whether the trigger signal and safety lock signal of the monitoring
page are displayed in green during welding;
    ③ Check whether the PWM, laser enabling and analog output of the monitoring
page are normal during welding.
     If the above conditions are normal, check the laser for abnormal alarm.
    Example: the air supply wire but not the light, for the laser fault or laser wiring
error. If neither air nor wire supply, the input signal may be missing, see: 2.1.3
Controller signal interface 1.
    Check whether the safety ground lock and other alarm of the monitoring interface
are normal.
appendix
     Laser welding machine three-phase power supply connection reference:
    Note: Two-phase or three-phase electricity depends on the power supply required
by the laser and the chiller, rather than the amount of wire harness.