L E G E N D S: GENERAL NOTES
1. ALL EQUIPMENT SHALL BE INSTALLED IN APPROXIMATE LOCATIONS AS SHOWN
ON THE DRAWINGS.
EXHAUST HOOD GUIDELINES: NOTES: 2. ALL EQUIPMENT SHALL SET ON LEVEL REINFORCED CONCRETE FOUNDATION AT
DRAIN PIPE
LEAST 150 mm HIGHER THAN THE FLOOR LINE, IF APPLICABLE.
249
3. ALL EQUIPMENT SHALL BE MOUNTED ON OR SUPPORTED WITH VIBRATION ISOLATION 302
102
FCU 3TR FREE STANDING UNITS OR ASSEMBLIES AS SPECIFIED AND OR AS SHOWN ON THE DRAWINGS.
4. INSTALLTION OF ALL WORKS SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER, 172
IMPROPERLY SETWORK OR FINISH AS DETERMINE BY THE ARCHITECT SHALL BE
Ø177
EQUIPMENT DESIGNATION REMOVED AND REPLACE AT NO EXTRA COST. 412
EQUIPMENT NUMBER 5. ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND CLEAN.
6. DEVIATIONS AND REVISIONS FROM PLANS SHALL BE REFFERRED TO THE OWNER Ø7,9
ACCU AIR COOLED CONDENSING UNIT
ARCHITECT / CONSULATANT / ENGINEERS FOR REVIEW AND APPROVAL.
294 70
7. ALL NECESSARY GOVERNMENT PERMIT SHALL BE SECURED/ PAID FOR BY
319 113
THE CONTRACTOR.
CEILING CONCEALED TYPE
8. ALL DIMENSIONS ARE IN MILLIMETER UNLESS OTHERWISE SPECIFIED.
9. ALL MECHANICAL WORKS SHALL BE IN ACCORDANCE WITH THE LATEST MECHANICAL
6300 6300 ENGINEERS CODE ASVE AND ASHRAE STANDARD.
2 AIR HANDLING UNIT DETAILS
SCALE
M-1 NTS
10. MECHANICAL CONTRACTOR SHALL OBSERVED ALWAYS SAFETY AND ORDERLINESS.
11. MECHANICAL CONTRACTOR SHALL VERIFY SITE PRIOR TO ACTUAL INSTALLATION.
3150 3150 3150 3150
EXHAUST AIR DUCT
TAPPING POINT
12. THE MECHANICAL CONTRACTOR SHALL CONDUCT TESTING OF ALL THE
A/C EQUIPMENT.
KITCHEN EXHAUST RANGE HOOD
13. REFRIGERANT PIPING SHALL BE COPPER OR COPPER TUBING, TYPE "L", ANNEALED
250 x 150 EAD
DEHYDRATED AND SEALED. SOFT TEMPER SHALL BE USED WHERE BENDING IS
48" - MAX.
REQUIRED AND WHERE FLARE JOINTS ARE USED. HARD DRAWN TUBING SHALL BE
USED WHERE NO BENDING IS REQUIRED AND SILVER BRAZED JOINTS ARE USED.
14. REFRIGERANT SUCTION AND LIQUID LINES SHALL BE INSULATED SEPARATELY
WITH 25 mm. THICK CLOSED CELL RUBBER INSULATION AND WRAPPED WITH
POLYTHELENE TAPE.
5652
5652
5652
5652
250 x 250 FAD 350 x 300 FAD
15. AS-BUILT PLANS SHALL BE SUBMITTED BY THIS CONTRACTOR AFTER
FRESH AIR DUCT
KITCHEN AREA KITCHEN AREA TAPPING POINT COMPLETION OF WORKS.
16. MECHANICAL A/C CONTRACTOR TO SUPPLY AND INSTALL ALL COMBINATION
MAGNETIC STARTER, AIR CIRCUIT BREAKER WITH OVERLOAD RELAY IN NEMA-3R
OR NEMA-1 ENCLOSURE FOR AIRCON UNITS.
17. THIS PLANS ARE DIAGRAMATIC LAYOUT ONLY, ANY MATERIALS AND FITINGS NOT
SHOWN OR NOT SPECIFED SHALL BE CONSIDERED INCLUDED WITH CONTRACTOR
SCOPE OF WORKS TO COMPLETE THE SYSTEM AND OPERATIONAL. 5 REF. PIPE SUPPORT DETAIL
3 PIPE RISER
SCALE
4 PIPING ISULATION DETAIL
SCALE
M-1 SCALE NTS
M-1 NTS M-1 NTS
1300
1300
PROVIDE VENTILATION PLAN AND FOLLOW BELOW GUIDELINES
15002
15002
15002
15002
COUNTER AREA COUNTER AREA
4345
4345
8050
8050
6 PIPE THRU WALL DETAIL 7 REF. PIPES THRU OUTSIDE WALL DETAIL
M-1 SCALE NTS M-1 SCALE NTS 8 DRAIN CONNECTION DETAIL
SCALE
M-1 NTS
5005
5005
3/8 DIAMETER HANGER ROD
EQUIPMENT SCHEDULE
TO BE CONNECTED AT EXISTING
STRUCTURE COOLING CAPACITY ENTERING AIR LEAVING AIR EVAPORATOR COIL DATA EVAPORATOR FAN DATA ELECTRICAL SUPPLY WEIGHT
UNIT QTY. TYPE AIRFLOW REMARKS
(CFM) 2 ( KG )
TR BTU/HR DB °C WB °C DB °C WB °C FACE AREA (M) FPI ROWS TYPE ESP, Pa DRIVE MOTOR (KW) VOLTS PHASE HERTZ
400 1 5.0 36,000
FREE STANDING
FREE BELOW/ 1,200 26.6 19.5 12.2 11.7 0.325 16 4
DIDW
150 DIRECT 2x 0.50 230 1 60 45
FLOOR MOUNTED TYPE, FREE BELOW, SPLIT TYPE
CARRIER MODEL.
SELF-SERVICE AREA CENTRIFUGAL
3955 2345 3955 2345 AIR DUCT
400
6300 6300 COOLING CAPACITY SATURATED TEMPERATURE CONDENSER COIL DATA CONDENSER FAN DATA COMP. MOTOR ELECTRICAL SUPPLY WEIGHT
4"
UNIT QTY. AIRFLOW REMARKS
(CFM) ( KG )
TR BTU/HR SUCTION °C DISCHARGE °C FACE AREA ROWS FPI TYPE MOTOR (KW) QTY/DIA. (mm) TYPE (KW) VOLTS PHASE HERTZ
HORIZONTAL DISCHARGE, TO MATCH THE FCU'S ABOVE MECH.
1 5.0 36,000 2,400 4.5 48 1.130 2 24 PROPELLER 0.184 1 / 460 DIRECT 3.20 230 1 60 82 CONTRACTOR TO INSTALL, WIRE AND MAKE UNIT OPERATIONAL
VARIES
HORIZONTAL DISCHARGE, TO MATCH THE FCU'S ABOVE MECH.
AIRCON LAYOUT PLAN DUCTING LAYOUT PLAN 1 KITCHEN EXHAUST FAN DETAILS
SCALE
M-1 NTS
PEDRO ANGELO SALIGUMBA PATIÑO
-
PROPOSED EATERY - RAINBOWL AS SHOWN
SM MARKETMALL, BRGY. BUROL MAIN, DASMARIÑAS CITY, CAVITE
M-2