AmaCan D, 60 HZ
AmaCan D, 60 HZ
AmaCan D
60 Hz
All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
edited or processed for any other purpose, nor otherwise transmitted, published or made available to a
third party without the manufacturer's express written consent.
Subject to technical modification without prior notice.
Contents
Water Applications: Water Transport / Waste Water Transport, Flood Protection..................................... 4
Submersible Pump in Discharge Tubes ..................................................................................................................................... 4
AmaCan D............................................................................................................................................................................. 4
Main applications........................................................................................................................................................... 4
Fluids handled ................................................................................................................................................................ 4
Operating data............................................................................................................................................................... 4
Designation .................................................................................................................................................................... 4
Design details ................................................................................................................................................................. 5
Materials ......................................................................................................................................................................... 5
Coating and preservation .............................................................................................................................................. 6
Product benefits ............................................................................................................................................................. 6
Acceptance tests and warranty ..................................................................................................................................... 6
Design and selection information................................................................................................................................. 6
Overview of product features / selection tables .......................................................................................................... 8
Specifications required for inquiries/orders ............................................................................................................... 10
Selection chart.............................................................................................................................................................. 11
Characteristic curves..................................................................................................................................................... 12
Dimensions ................................................................................................................................................................... 63
Installation types .......................................................................................................................................................... 67
Scope of supply ............................................................................................................................................................ 67
Accessories .................................................................................................................................................................... 68
General assembly drawing with list of components.................................................................................................. 72
Index ................................................................................................................................................................ 73
3
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Water Applications: Water Transport / ▪ Raw water pumps and clean water pumps in waterworks
and waste water treatment plants
Waste Water Transport, Flood Protection
▪ Cooling water pumps in power stations and in industry
Submersible Pump in Discharge Tubes ▪ Industrial water supply
▪ Water pollution control
▪ Flood control
AmaCan D ▪ Aquaculture
Fluids handled
▪ Waste water
▪ Sludge
▪ Surface water
▪ Stormwater
▪ Gray water
▪ Seawater
▪ Brackish water
Operating data
Table 1: Operating properties
Characteristic Value
Flow rate Q [US.gpm] ≤ 31700
Q [l/s] ≤ 2000
Head H [ft] ≤ 120
Main applications H [m] ≤ 36
▪ Irrigation pumping stations Motor rating P₂ [hp] ≤ 455
▪ Drainage pumping stations P₂ [kW] ≤ 340
Fluid temperature T [°F] ≤ +104
▪ Stormwater pumping stations
T [°C] ≤ +40
Designation
Code Description
AmaCan Type series
D Impeller type
D Open mixed-flow multi-vane impeller
B Impeller variant
A
B
3 Number of vanes
2
3
600 Nominal diameter of the discharge tube [mm]
420 Nominal impeller diameter [mm]
1581.56/01-EN-US
4 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Code Description
IE3 Motor efficiency classification1)
-2) No efficiency classification
IE3 Premium Efficiency
Materials
Table 3: Overview of materials depending on material variant (EN and ASTM)
Part No. Description Material variant
G1 G2 G34)
(seawater variant)
112 Pump bowl EN: EN-GJL-250/ASTM: A48 Cl. 35B
138 Bellmouth EN: EN-GJL-250/ASTM: A48 Cl. 35B
230 Impeller EN: 1.4593/1.4517/ASTM: A995 Gr. 1B
350 / Bearing housing / bearing bracket EN: EN-GJL-250/ASTM: A48 Cl. 35B
330
360 Bearing cover EN: EN-GJL-250/ASTM: A48 Cl. 35B
412 O-ring EN/ASTM: NBR5)
EN: (Viton FPM)6)/ASTM: (Viton FKM)
433 Mechanical seal SiC/SiC
(pump end)
1581.56/01-EN-US
1 The IEC 60034-30 standard is not binding for submersible motor pumps. Efficiencies are calculated / determined by analogy
with the measurement method specified in IEC 60034-2. The marking is used for submersible motors that achieve efficiency
levels similar to those of standardized motors acc. to the IEC 60034-30 standard.
2 Blank
3 ECB = Self-cleaning blade profile (EverCleanBlade)
4 Pump set with cathodic protection (anodes to be checked every 6 to 12 months) and top coat of 250 µm
5 Nitrile rubber (Perbunan)
6 FPM fluorocarbon rubber variant available as an option against a surcharge
AmaCan D 5
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Description of materials
Duplex stainless steel (1.4517 or technically equivalent material)
This type of cast steel is resistant to cavitation, has excellent strength values and is used for high circumferential speeds. An
excellent resistance to pitting corrosion makes ferritic-austenitic stainless steel a popular choice for pumping acidic waste water
with a high chloride content as well as seawater and brackish water. Thanks to its good chemical resistance, e.g. against waste
water containing phosphorus and sulphuric acid, this material is used in a wide range of applications in the chemical industry and
process engineering. Pumps made of duplex stainless steel have a very long service life, even when handling brines, chemical
waste water (pH 1 - 12), gray water and landfill leachate.
Acceptance tests
Special coating
▪ Acceptance testing to ISO/DIN or comparable standards is
▪ Available on request (extra charge and a longer delivery available against a surcharge.
period apply).
Warranty
Product benefits ▪ Quality is assured by means of an audited and certified
▪ The pump’s own weight ensures self-centering seating in quality assurance system to DIN EN ISO 9001.
the discharge tube, and an O-ring seals it; quick to install
or remove without additional anchoring or anti-rotation
device. Design and selection information
▪ Non-clogging low-maintenance design with large free
passages reduces clogging risk and, consequently, Information for pump selection
maintenance work.
The guaranteed point of submersible pumps in discharge tubes
▪ The slim motor keeps discharge tube flow losses down. is measured at a head of 1.65 ft [0.5 m] above the motor. The
▪ Optimum hydraulic and energy efficiency by high- documented characteristic curves refer to this data. This must
efficiency motors and variable hydraulic systems be taken into account when calculating system losses. The
indicated heads and performance data apply to pumped fluids
▪ High reliability thanks to bearing temperature monitoring, with a density ρ = 7.48 lbs/ft3 [1 kg/dm3] and a kinematic
vibration sensor, thermal motor protection, leakage viscosity ν of up to 20 mm2/s.
sensors in the motor space and connection space as well as
▪ Adjust the power input to the density of the fluid
1581.56/01-EN-US
6 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Intake chamber
Determine the minimum water level t1min (diagram in general
arrangement drawing):
The minimum water level t1min is the water level required in the
pump's suction chamber to ensure the following:
▪ The hydraulic system (propeller) is sufficiently submerged
(shown in diagram depending on pump size).
▪ The pump does not draw in air-entraining vortices (shown
in diagram depending on flow rate).
▪ The hydraulic system is free from cavitation (check against
the NPSHrequired value in the technical literature. The
following conditions must be met:
– NPSHavailable > NPSHrequired + safety allowance
– NPSHavailable = 10.0 + (t1 - t3 - h7/2)
– Safety allowance:
up to Qopt ⇒1.65 ft [0.5 m]
larger than Qopt ⇒ 3.3 ft [1.0 m]
Head (H)
The total pump head is composed as follows:
H = Hgeo + Δ HV
Hgeo (static head)
▪ Without discharge elbow – Difference between suction-
side water level and overflow edge
▪ With discharge elbow – Difference between suction-side
and discharge-side water level
Δ HV (losses in the system)
▪ Starting 1.65 ft [0.5 m] downstream of the pump: e.g. pipe
friction, elbow, swing check valve, etc.
8 If larger power reserves are stipulated by local regulations, these larger reserves must be provided.
AmaCan D 7
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Table 5: Selection aid for material variants and fluid temperature per fluid
Fluid handled9)
fluid tem-
Max. per-
Comments, further recommendations
perature
missible
Material
variant
Screen
[°F] [°C]
Waste water
▪ Industrial, corrosive, non-abrasive, slightly acidic; pH 104 40 G2 ✔ 2-component high solid epoxy finish coat
value ≥ 6 (RAL 5002) 250 µm required
9 Fluids to be pumped which are not listed in this table usually require higher-grade materials. Contact the manufacturer.
10 For t > 77 °F [25 °C] contact KSB (stainless steel variant).
11 Efficiency reduced by 2 % to 3 %; anode to be checked every 6 to 12 months
8 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Size Required space between screen bars Size Required space between screen bars
[inch] [mm] [inch] [mm]
800-460 1 9/16 40 900-630 3 1/8 80
800-580 2 3/8 60 900-650 3 1/8 80
1000-650 3 1/8 80
AmaCan D 9
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Specifications required for inquiries/orders – For a support rope indicate dimension "L", the
number of additional lifting rings (depending on the
▪ Designation of the pump lifting height of the lifting equipment) as well as the
▪ Flow rate Q, head Htotal elevations and type of installation.
▪ Type of fluid handled and fluid temperature Always define dimension "L" when ordering a support rope to
allow the correct length to be determined. The lifting height
▪ Voltage, frequency, starting method, cable length of the crane must be taken into account when ordering a sup-
port rope. This determines the number of lifting rings re-
▪ Quantity and language of operating manuals quired for installing the pump in or removing it from the dis-
▪ Required accessories charge tube.
– For discharge tubes indicate all required elevations 1
and the type of installation.
– For flow-straightening vanes indicate the type of
installation and design (with or without suction
umbrella). 2
4
1581.56/01-EN-US
10 AmaCan D
1581.56/01-EN-US
Selection chart
AmaCan D 60 Hz, n = 1750 / 1160 / 875 rpm (diameter-based selection chart)
50
40
700/800-460B2 4p 900-630B2 6p
600/700-390B3 4p 20
900-630B3 8p
600/700-390B2 4p
50 900-630A3 8p
4
600/700-420B2 6p
600/700-420A3 6p 900/1000-650A3 8p
10 3
800-580B2 8p 800-580A3 8p
H
4
2000 3000 4000 5000 Q[US.gpm] 10000 20000 30000 40000
AmaCan D
Characteristic curves
n = 1750 rpm
1581.56/01-EN-US
12 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
H [ft] 84 82
83.1 80
82
82
40 80
80 ø397
75 10
75 70
70 ø381
20
ø365
NPSH [m]
40 3%
10
NPSH [ft]
3%
20 6
150
100
P [hp]
100 P [kW]
ø397
ø381 50
50
ø365
AmaCan D 13
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
1581.56/01-EN-US
19 - = No efficiency classification
14 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
100 Qmin
85 30
86
η [%]
87
87.2 H [m]
80 85 87
86 86
86.2 85
83 20
86
83
60 85
84.1 ø388
83
H [ft]
83 80
40 80
ø372
75 10
70
20 ø357
20
5
200
P [hp]
ø388
150
100
ø372
100 P [kW]
ø357 50
AmaCan D 15
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
1581.56/01-EN-US
20 - = No efficiency classification
16 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
80 84.5
84.2
H [ft] H [m]
82
82
82.1
40 82 82 80
80
80 75 10
75
70
75 70
20 70
ø416
ø403
ø389
NPSH [m]
3%
40
10
NPSH [ft]
3%
20
200
150
100
P [hp]
ø403
50
50 ø389
AmaCan D 17
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
1581.56/01-EN-US
21 - = No efficiency classification
18 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
80 86 η [%]
82
100 H [m]
84 86.8
80
86
80 82
85.9
84
84 82 20
83.8
60 80
82
82 80
H [ft] 80 ø463
75
40 75
70 ø444
20 ø426
ø444 ø463
ø426
20
60
40
10
20
300
200
P [hp]
ø463
200 P [kW]
ø444 100
100
ø426
AmaCan D 19
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
1581.56/01-EN-US
22 - = No efficiency classification
20 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
n = 1160 rpm
1581.56/01-EN-US
AmaCan D 21
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Qmin
84
85
40
86 η [%]
82
86.2
84
86
85
10
85
30 82 85.2
85 84
84 82
H [ft] H [m]
83.3 80
82
82 80
20 ø391
80
75
5
75
ø378
70
10
ø364
10 3
60
40
P [hp]
ø391
40 P [kW]
ø378
20
ø364
20
22 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
23 - = No efficiency classification
AmaCan D 23
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Qmin 75
40 80
82
84 η [%]
80 10
82 84.8
30
84
80
H [ft] 83.9
H [m]
82
82 80
81.8
20
80
80 ø397
5
75
75
70
70
10 ø381
ø365
5
NPSH [ft]
3%
10
40 30
P [kW]
30
ø397
20
P [hp]
20 ø381
ø365 10
10
3000 3500 Q [US.gpm] 4000 4500 5000
K43910 US/0
1581.56/01-EN-US
24 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
24 - = No efficiency classification
AmaCan D 25
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Qmin 83
84
40 85
η [%]
83 85.9
84
85 10
81 84
30 84.8
82 83
82
84 81
H [ft] 82.8 83 H [m]
82
ø388
81
82 80
20 81
80
75
5
75 ø372
70
10
ø357
5
60
40
50
ø388 P [kW]
40 30
P [hp]
ø372
30
20
20 ø357
26 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
25 - = No efficiency classification
AmaCan D 27
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Qmin 82
80 10
84 η [%]
82
84.3
30
84
80
83.7
H [ft] H [m]
82
81.8
82 80
20 80
80 75
75 5
70
75
70
70
10 ø418
ø408
ø398
10
80 60
P [kW]
60
40
P [hp] ø418
40 ø408
ø398 20
20
7000 8000 Q [US.gpm] 9000 10000 11000 12000
K43687 US/0
1581.56/01-EN-US
28 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
26 - = No efficiency classification
AmaCan D 29
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
82 83.8
H [ft] H [m]
82.9 83
80
82
20 82
80.8 80
80 5
80
75
75
70
75 70
10
70
ø416
ø403
ø389
NPSH [ft]
3%
NPSH [m]
3%
15
10
60
40
P [hp]
40 P [kW]
ø416
20
ø403
20
ø389
30 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
27 - = No efficiency classification
AmaCan D 31
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Qmin
η [%] 10
85.0
82
30
84.0 84
80
H [ft] H [m]
82
82 80
81.9
20 80
75
80 75
5
ø416
70
75
70 ø403
10
ø389
NPSH [m]
3%
20
80 60
P [hp]
P [kW]
60
ø416
40
ø403
40
ø389
20
32 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
28 - = No efficiency classification
AmaCan D 33
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
H [ft] 84 86.9
H [m]
82 86
40 85.8
84
84 82
83.9 80 10
82
82 80 ø456
80
75
20 75
70 ø440
ø425
NPSH [m]
3%
20
140
100
120
80
ø456
100
P [kW]
80 60
P [hp] ø440
60
40
ø425
40
6000 7000 Q [US.gpm] 8000 9000 10000 11000
K43913 US/0
1581.56/01-EN-US
34 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
29 - = No efficiency classification
AmaCan D 35
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
ø426
20
10
100
80 60
P [kW]
ø463
60
40
P [hp]
ø444
40
ø426 20
20
4500 5000 5500 Q [US.gpm]
6000 6500 7000 7500 8000
K43920 US/0
1581.56/01-EN-US
36 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
30 - = No efficiency classification
AmaCan D 37
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Qmin
60 84 18
η [%]
86
H [ft] 86.5
84
86 H [m]
82 85.5
40 84
82
83.5 84
ø452 10
82
82 80
80 75
20 75 ø434
70
ø416
20
120
80
100 ø452
P [kW]
80 60
P [hp] ø434
60
40
ø416
40
38 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
31 - = No efficiency classification
AmaCan D 39
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Qmin
60 85 18
84 85.8 η [%]
H [ft]
H [m]
84.9 85
82
84
40
84
82.8 82
82 80 10
82
80
80 75
75
70
20 75 70
ø581
70
ø562
ø542 2
7
20
300
200
P [hp]
200 P [kW]
ø581
100
ø562
100
ø542
40 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
32 - = No efficiency classification
AmaCan D 41
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Qmin
80
82
100 84 30
80 86
82 η [%]
84 87.1 H [m]
80
80
82 86 86
86.2 20
86
84
60
8484.1 84 82
84
H [ft] 80
82
82 80 ø643
40 80
75
75 10
ø618
70
20 ø593
60 18
ø593 ø618 ø643
40
10
20
500
400 300
P [hp]
P [kW]
ø643
300
200
ø618
200
ø593 100
42 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
33 - = No efficiency classification
AmaCan D 43
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
H [ft] 84 H [m]
83.3 84
82
40 82 80
82 80
75 10
80
75
70
75 70
20 70 ø645
ø624
ø602
NPSH [m]
40 3%
10
25
500
400 300
P [kW]
300
200
P [hp] ø645
200
ø624
ø602 100
100
18000 20000 22000 Q [US.gpm]
24000 26000 28000 30000 32000
K43886 US/0
1581.56/01-EN-US
44 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
34 - = No efficiency classification
AmaCan D 45
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
n = 875 rpm
1581.56/01-EN-US
46 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
84 85.8
10
85
30 82 85.2 85
85 84
ø555
200
150
100
P [hp]
ø584
100 P [kW]
ø570
50
ø555
50
14000 16000 18000 Q [US.gpm]
20000 22000 24000
K43874 US/0
1581.56/01-EN-US
AmaCan D 47
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
1581.56/01-EN-US
35 - = No efficiency classification
48 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
84 85
80
H [ft] 84.2
84 H [m]
84
82
82
82.2
20 82
82 80
80
5
80 75
75
70
75 70
10 70 ø581
ø562
ø542
5
NPSH [ft]
3%
10
100
120
80
100
P [kW]
80 60
P [hp]
ø581
60
40
ø562
40
ø542
AmaCan D 49
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
1581.56/01-EN-US
36 - = No efficiency classification
50 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
40 Qmin
86
η [%]
86.4
84
10
86
30 85.4
82
84
H [ft] 84
82 H [m]
83.4 82 80
80 ø581
20 82
80 75
5
75 ø562
70
10 ø542
ø562 ø581
40
ø542
10
NPSH [ft]
3%
NPSH [m]
3%
20
150
ø581 100
P [hp]
100 P [kW]
ø562
ø542 50
AmaCan D 51
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
1581.56/01-EN-US
37 - = No efficiency classification
52 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Qmin
86 20
87 η [%]
60
84 87.8
86
H [ft] H [m]
87
86.8 86
84
40 86 84
84.9 82
84
84 82 ø634 10
82 80
80
75
75
20 ø612
70
ø591
20
300
200
P [hp]
ø634
200 P [kW]
ø612
100
100 ø591
AmaCan D 53
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
1581.56/01-EN-US
38 - = No efficiency classification
54 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Qmin
60 80
18
82
84
80 86 η [%]
H [ft] 82
86.5 H [m]
84
80 86
40
82 85.5
84
84 82 10
83.4
80
82
82 80 ø643
80
75
20
75
ø618
70
ø593
2
20
5
10
200 150
P [kW]
150
ø643 100
P [hp]
100
ø618
50
ø593
50
9000 10000 11000 Q [US.gpm]
12000 13000 14000 15000 16000 17000
K43945 US/0
1581.56/01-EN-US
AmaCan D 55
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
1581.56/01-EN-US
39 - = No efficiency classification
56 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Qmin 20
86 η [%]
60 87
84
87.5
H [ft] 86 87 H [m]
86
86.5
84
84 86
40 82
84.4 ø628
84
84 82 10
80
82
80
75 ø603
20
70
ø578
20
200
250
P [kW]
ø628
200 150
P [hp]
150 ø603
100
100 ø578
AmaCan D 57
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
1581.56/01-EN-US
40 - = No efficiency classification
58 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
ø633
10
ø617
ø648 14
40 ø633 NPSH [m]
3%
ø617 10
NPSH [ft]
3%
20
300
200
P [hp]
200 P [kW]
ø648
ø633
100
100 ø617
AmaCan D 59
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
1581.56/01-EN-US
41 - = No efficiency classification
60 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
85 H [m]
40
86
85.8
85
83
85 10
83
30
83.8 83
80
H [ft] 83 80
75 ø645
80
20
75 ø624
5
70
ø602
10
18000 20000 22000 Q [US.gpm]
24000 26000 28000
10
20 6
300
200
250
P [kW]
ø645
200 150
P [hp]
ø624
150
100
ø602
100
18000 20000 22000 Q [US.gpm]
24000 26000 28000
K43884 US/0
1581.56/01-EN-US
AmaCan D 61
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
1581.56/01-EN-US
42 - = No efficiency classification
62 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Dimensions
Dimensions [inch]
l2
d5
h2
d4
h4
d1
h1
l1
h3
d2
d3
Fig. 1: Pump set dimensions
600-390 47 6 23 19 2/3 20 6/7 15 1/6 1 4/7 89 5/7 88 1/7 20 1/3 62 1/2 28 3/7 3 1/7 2085
600-390 60 6 23 19 2/3 20 6/7 15 1/6 1 4/7 89 5/7 88 1/7 20 1/3 62 1/2 28 3/7 3 1/7 2085
600-390 65 6 23 19 2/3 20 6/7 15 1/6 1 4/7 89 5/7 88 1/7 20 1/3 62 1/2 28 3/7 3 1/7 2120
600-390 80 6 23 19 2/3 20 6/7 15 1/6 1 4/7 97 3/5 96 20 1/3 70 2/5 28 3/7 3 1/7 2340
600-390 100 6 23 19 2/3 20 6/7 15 1/6 1 4/7 97 3/5 96 20 1/3 70 2/5 28 3/7 3 1/7 2440
600-390 120 6 23 19 2/3 20 6/7 15 1/6 1 4/7 97 3/5 96 20 1/3 70 2/5 28 3/7 3 1/7 2540
700-390 150 4 23 19 2/3 20 6/7 18 5/7 1 4/7 110 1/4 108 2/3 20 1/3 83 28 3/7 3 1/7 3430
43 Pump set in material variant G3, with 33 ft [10 m] power cable and 16.4 ft [5 m] support rope. The indicated weights are
reference values only. Refer to the data sheet for the exact weight.
AmaCan D 63
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
900-650 290 6 34 1/2 30 30 1/3 21 6/7 2 123 1/4 121 26 7/9 99 2/3 40 1/2 3 1/2 6340
900-650 340 6 34 1/2 30 30 1/3 21 6/7 2 123 1/4 121 26 7/9 99 2/3 40 1/2 3 1/2 6640
900-650 140 8 34 1/2 30 30 1/3 18 5/7 1 4/7 113 111 1/2 26 7/9 85 6/7 40 1/2 3 1/7 4500
900-650 160 8 34 1/2 30 30 1/3 18 5/7 1 4/7 113 111 1/2 26 7/9 85 6/7 40 1/2 3 1/7 4630
900-650 205 8 34 1/2 30 30 1/3 21 6/7 2 123 1/4 121 26 7/9 99 2/3 40 1/2 3 1/2 6020
900-650 250 8 34 1/2 30 30 1/3 21 6/7 2 123 1/4 121 26 7/9 99 2/3 40 1/2 3 1/2 6320
900-650 290 8 34 1/2 30 30 1/3 21 6/7 2 123 1/4 121 26 7/9 99 2/3 40 1/2 3 1/2 6615
64 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Dimensions [mm]
l2
d5
h2
d4
h4
d1
h1
l1
h3
d2
d3
Fig. 2: Pump set dimensions
600-390 80 6 582 500 530 385 40 2479 2439 517 1788 722 80 1060
600-390 100 6 582 500 530 385 40 2479 2439 517 1788 722 80 1105
600-390 120 6 582 500 530 385 40 2479 2439 517 1788 722 80 1150
700-390 150 4 582 500 530 475 40 2800 2760 517 2109 722 80 1555
700-390 170 4 582 500 530 475 40 2800 2760 517 2109 722 80 1555
600-420 90 4 580 510 510 385 40 2443 2403 486 1752 673 80 1045
600-420 105 4 580 510 510 385 40 2443 2403 486 1752 673 80 1085
44 Pump set in material variant G3, with 10-meter power cable and 5-meter support rope. The indicated weights are reference
values only. Refer to the data sheet for the exact weight.
AmaCan D 65
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
900-650 205 8 876 760 770 555 50 3131 3072 680 2532 1028 90 2730
900-650 250 8 876 760 770 555 50 3131 3072 680 2532 1028 90 2865
900-650 290 8 876 760 770 555 50 3131 3072 680 2532 1028 90 3000
66 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Installation types
Table 36: Overview of installation types
AmaCan D 67
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Accessories
Design of the intake chamber wall surfaces (to prevent vortex formation)
The flow-straightening vane is indispensable for the inlet conditions of the pump set. It prevents the development of a submerged
vortex (floor vortex) which could cause a drop in performance, for example. In addition, the floor and wall surfaces of the intake
chamber should be designed as a rough concrete surface. Rough surfaces minimize the separation of boundary layers that may
cause wall and floor vortices.
1581.56/01-EN-US
68 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
Variant 1 Variant 2
Flow-straightening vane cast from concrete Steel section
s2
sR
s1
hR
hR
A
D
(e1) (e1)
lR lR
AmaCan D 69
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
59-8
59-17.2
59-24
720
59-47*
A A
59-7
59-17.1
*= The number of (intermediate) lifting rings depends on the lifting height of the hoisting tackle and on the building structure.
(Intermediate lifting rings are supplied as an option).
70 AmaCan D
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
2 6
5 4
A-A
4 3
2 6 5 1 6
1 Discharge tube cover47) 4 Threaded bush with cable entry to DIN 22419
with strain relief and protection against kink-
ing and twisting
2 Cover 5 Eyeplate for fastening the cable support
(support rope)
3 Welding sleeve 6 Gasket, e.g. fabric-reinforced rubber
AmaCan D 71
Water Applications: Water Transport / Waste Water Transport, Flood Protection
Submersible Pump in Discharge Tubes
834
571
812
412
330
811
(80-1)
818
360
412
350
412
412
112 433
502 230
138
UG2096168
72 AmaCan D
Index
Index
B
Bearings 5
D
Design 5
Designation 4
Drive 5
I
Impeller type 5
M
Materials 5
S
Scope of supply 67
Shaft seal 5
1581.56/01-EN-US
73
2023-11-28
1581.56/01-EN-US