Hardware Engineer's Guide
CONNECTORS             & CABLES
      ByShimiCohen
Connectors and Cables
               Connector Type      Pins Pinout
            1 USB        Type-C     24
            2 HDMI       A          19
            3 RJ45       8P8C       8
            4 PWR Jack   5.5/2.1   2–3
 2
Connectors and Cables
          Conn          Type   Pins   Pinout
     5    Audio Jack    TRS     2-4
     6    DisplayPort   STD      24
     7    SWD           20p      20
     8    SMA           SMA      1
 3
Connectors and Cables
          Conn          Type         Pins Pinout
     9    SD            Mini/Micro   8-9
     10   SATA          Molex         5
     11   BNC           50Ω/75Ω       2
     12   RS232         D-SUB         9
          DB-9
 4
Connectors and Cables
       INTERCONNECT BASICS
       Electrical interconnects serve as the circulatory system of electronic hardware.
       They enable power distribution, signal transmission, and data transfer between
       discrete components, PCBs, and subsystems.
       PRIMARY FUNCTIONS:
          •   Signal path establishment between processing units
          •   Power delivery from sources to loads
          •   Grounding and EMI management
          •   Mechanical support and positioning
          •   Environmental protection of electrical connections
       SYSTEM IMPACT ANALYSIS:
          •   Interconnects directly affect system reliability
          •   Signal integrity degradation increases with poor interconnect design
          •   Cost optimization requires balanced connector selection strategies
          •   Maintenance accessibility depends on interconnect architecture
 5
Connectors and Cables
       BOARD-TO-WIRE CONFIGURATIONS:
          •   Direct PCB termination for fixed installations
          •   Removable connectors for serviceable systems
          •   Mixed architectures for modular designs
          •   Hybrid power/signal distribution schemes
       BOARD-TO-BOARD CONFIGURATIONS:
          •   Parallel PCB stacking with vertical connectors
          •   Perpendicular board mounting with right-angle interfaces
          •   Flexible circuit interconnection for dynamic assemblies
          •   Backplane architectures for scalable systems
       WIRE-TO-WIRE CONFIGURATIONS:
          •   In-line splicing for harness extensions
          •   Junction boxes for multi-branch distribution
          •   Sealed connectors for harsh environment applications
          •   Quick-disconnect systems for field maintenance
 6
Connectors and Cables
       LEVEL 1: COMPONENT LEVEL
          •   IC package interconnects (BGA, QFP, LGA)
          •   Passive component terminations
          •   Test point accessibility
          •   Thermal management interfaces
       LEVEL 2: PCB LEVEL
          •   On-board trace routing optimization
          •   Via placement and sizing strategies
          •   Layer stack-up for signal integrity
          •   Ground plane continuity maintenance
       LEVEL 3: SYSTEM LEVEL
          •   Inter-PCB connection planning
          •   Cable harness architecture design
          •   Connector placement optimization
 7
Connectors and Cables
       CONNECTOR STANDARDS
       D-SUB CONNECTORS:
          •   Standard: DA-15, DB-25, DC-37, DD-50, DE-9
          •   Applications: Serial, parallel, control
          •   Current ratings: 5A (per), 13A (max)
          •   Voltage ratings: 250VAC/350VDC standard
       USB CONNECTORS:
          •   USB-A: Host-side standard connector
          •   USB-B: Device-side square connector
          •   USB-C: Reversible, HP capable (100W)
          •   Micro-USB: Mobile device standard
          •   Mini-USB: Legacy mobile applications
       HIROSE CONNECTORS:
          •   DF Series: 7.92mm pitch, 30A rating
          •   GT Series: 3.0mm pitch, 3A rating
          •   FX Series: 1.25mm pitch, 1A rating
          •   HR Series: 1-2.5mm pitch, 2-3A rating
       MOLEX CONNECTOR SYSTEMS:
          •   Mini-Fit: 4.2mm pitch (8.5A)
          •   Micro-Fit: 3.0mm pitch (5A)
          •   KK: 2.54mm pitch (3A)
          •   Pico-Blade: 1.25mm pitch (1A)
 8
Connectors and Cables
       SIGNAL CONNECTORS:
          •   Low-level analog signals (<1V)
          •   Digital logic levels (3.3V, 5V, 12V)
          •   High-speed differential pairs
          •   RF and microwave applications
       POWER CONNECTORS:
          •   DC power distribution (12V, 24V, 48V systems)
          •   AC mains connections (120VAC, 240VAC)
          •   High-current applications (>10A per contact)
          •   Battery interconnections
       HYBRID CONNECTORS:
          •   Combined power and signal in single housing
          •   Ethernet with PoE (Power over Ethernet)
          •   USB with power delivery capability
          •   Multi-function automotive connectors
       HIGH-FREQUENCY CONNECTORS:
          •   Coaxial connectors (SMA, BNC, N-type)
          •   Board-mount RF connectors
          •   Millimeter-wave applications
          •   Impedance-controlled designs (50Ω, 75Ω)
 9
Connectors and Cables
       IP RATING SYSTEM:
        IP Code         Dust Protection         Water Protection      Typical Applications
         IP44 Protected against 1mm objects      Splash resistant      Indoor electronics
         IP65              Dust tight           Water jet resistant   Outdoor equipment
         IP67              Dust tight           Immersion to 1m       Marine applications
         IP68              Dust tight         Continuous immersion Underwater systems
       MIL-STD ENVIRONMENTAL CLASSIFICATIONS:
          •     MIL-STD-810: Environmental testing procedures
          •     MIL-DTL-38999: Circular connector specifications
          •     MIL-DTL-83723: Rectangular connector standards
          •     MIL-STD-1344: Connector reliability testing
          •     Mating force: 10-50N typical for manual connections
          •     Insertion cycles: 10-10,000 depending on application
          •     Vibration resistance: 10-2000Hz, 20G acceleration
          •     Shock resistance: 50-100G peak acceleration
          •     Temperature cycling: -55°C to +125°C for military applications
 10
Connectors and Cables
       CABLE TYPES
       COAXIAL CABLES:
           •     Single center conductor with concentric shield
           •     Controlled impedance (50Ω, 75Ω standard)
           •     Applications: RF signals, high-speed digital, video
           •     Construction: Center conductor → Dielectric → Shield → Jacket
       Common Coaxial Types:
        Cable Type Impedance Center Conductor Dielectric   Applications
        RG-58        50Ω       20 AWG solid    Polyethylene General purpose RF
        RG-6         75Ω       18 AWG solid    Foam PE     Cable TV, satellite
        RG-213       50Ω       13 AWG stranded Polyethylene High-power RF
       TWISTED PAIR CABLES:
           •     Balanced transmission line
           •     Cat5e, Cat6, Cat6A, Cat7, Cat8
           •     Ethernet, telephony, industrial
       Twisted Pair Performance:
        Category Bandwidth Max Length Crosstalk (NEXT)      Applications
         Cat5e     100 MHz     100m    35.3 dB @ 100MHz 1 Gigabit Ethernet
          Cat6     250 MHz     100m    39.9 dB @ 100MHz 1 Gigabit Ethernet
         Cat6A     500 MHz     100m    42.4 dB @ 500MHz 10 Gigabit Ethernet
          Cat7     600 MHz     100m    62.1 dB @ 600MHz 10 Gigabit Ethernet
 11
Connectors and Cables
       SHIELDED CABLES:
           •    Overall shield (OS): Single shield around conductors
           •    Individual shield (IS): Shield per conductor pair
           •    Combined (S/FTP): Overall + individual shields
       RIBBON CABLES:
           •    Multiple parallel conductors in flat configuration
           •    Standard pitches: 0.05", 0.1", 1.27mm, 2.54mm
           •    Internal computer connections, test equipment
       FLEXIBLE FLAT CABLES & PCB(FFC&FPC):
           •    Ultra-thin profile (0.1-0.3mm typical)
           •    High conductor density (0.5mm pitch common)
           •    Construction: Copper traces on polyimide
       IMPEDANCE CHARACTERISTICS:
           •    Characteristic impedance (Z₀): Function of conductor geometry & dielectric
           •    Coaxial cable: 𝑍₀ = 60 × 𝑙𝑛(𝐷/𝑑) / √𝜀ᵣ
           •    Twisted pair: 𝑍₀ = 120 × 𝑙𝑛(2𝑆/𝑑) / √𝜀ᵣ
       CONDUCTOR SIZING:
        AWG Size Diameter (mm) Resistance (Ω/km) Current Rating (A) Typical Applications
           30           0.255           339               0.5           Signal wires
           28           0.321           213               0.8           Signal wires
           26           0.405           134               1.3           Signal wires
           24           0.511          84.2               2.1         Signal/low power
           22           0.644          53.0               3.3            Low power
           20           0.812          33.3               5.2          Medium power
           18           1.024          21.0               8.2          Medium power
           16           1.291          13.2               13            High current
 12
Connectors and Cables
       INSULATION MATERIALS:
          •   PVC: General purpose, -10°C to +70°C, low cost
          •   Polyethylene: Low dielectric loss, -40°C to +80°C
          •   PTFE (Teflon): Chemical resistance, -200°C to +260°C
          •   Polyimide: High temperature, -269°C to +400°C
          •   XLPE: Cross-linked polyethylene, improved thermal properties
       JACKETING MATERIALS:
          •   PVC: Indoor applications, flame retardant options
          •   Polyurethane: Flexibility, abrasion resistance
          •   TPE (Thermoplastic Elastomer): Oil resistance, flexibility
          •   Fluoropolymers: Chemical resistance, low smoke generation
       SHIELDING EFFECTIVENESS:
          •   Braided shield: 85-95% coverage, 20-40 dB attenuation
          •   Foil shield: 100% coverage, 10-30 dB attenuation
          •   Combination: 90-95% braid over foil, 40-80 dB attenuation
          •   Spiral wrap: 60-80% coverage, 10-20 dB attenuation
 13
Connectors and Cables
       SIGNAL INTEGRITY
       PROPAGATION DELAY CALCULATION:
          •   Velocity of propagation (𝑉𝑝) = 𝑐 / √𝜀ᵣ
          •   Propagation delay = 𝐿𝑒𝑛𝑔𝑡ℎ / 𝑉𝑝
          •   Typical values: 1.5-2.0 ns/ft for common cables
          •   Critical for high-speed digital systems and timing analysis
       REFLECTION ANALYSIS:
          •   Occurs at impedance discontinuities
          •   Reflection coefficient: 𝜌 = (𝑍₂ − 𝑍₁) / (𝑍₂ + 𝑍₁)
          •   Standing wave ratio: 𝑆𝑊𝑅 = (1 + |𝜌|) / (1 − |𝜌|)
          •   Target: 𝑆𝑊𝑅 < 1.5 for good signal quality
 14
Connectors and Cables
       VOLTAGE DROP CALCULATION:
           •   Vₐᵣₒₚ = I × R × 2 (for DC circuits, round trip)
           •   R = ρ × L / A (resistance calculation)
           •   Where: ρ = resistivity, L = length, A = cross-sectional area
       CURRENT DERATING FACTORS:
        Condition                      Derating Factor Typical Applications
        Single conductor in free air   1.0             Reference condition
        Cable bundle (3-6 conductors) 0.8              Harness assemblies
        Cable bundle (7-24 conductors) 0.7             Multi-conductor cables
        Elevated temperature (+40°C)   0.82            Engine compartments
        Elevated temperature (+60°C)   0.71            Industrial ovens
       POWER DELIVERY DESIGN EXAMPLE:
           •   Load: 5V @ 10A
           •   Cable length: 3 meters
           •   Voltage drop budget: 2% (0.1V)
           •   Required wire resistance: 0.1V / 10A = 0.01Ω
           •   18 AWG copper: 21.0 Ω/km × 0.006km = 0.126Ω (too high)
           •   14 AWG copper: 8.29 Ω/km × 0.006km = 0.050Ω (too high)
           •   12 AWG copper: 5.21 Ω/km × 0.006km = 0.031Ω (marginal)
           •   10 AWG copper: 3.28 Ω/km × 0.006km = 0.020Ω (acceptable)
 15
Connectors and Cables
       SIGNAL RISE TIME IMPACT:
          •   Transmission line effects become significant when:
          •   Cable length > Vp × tᵣᵢₛₑ / 6
          •   For 2ns rise time: Critical length ≈ 0.3m
          •   Faster signals require more careful cable design
       DIFFERENTIAL PAIR IMPLEMENTATION:
          •   Common mode rejection improves EMI immunity
          •   Skew matching: <10% of rise time
          •   Impedance matching: 100Ω ±10% typical
          •   Length matching: <5mm for Gbps signals
       HIGH-SPEED DESIGN GUIDELINES:
        Data Rate Max Skew Impedance Tolerance Length Matching
        100 Mbps    1ns           ±20%             ±10mm
         1 Gbps    100ps          ±10%             ±5mm
        10 Gbps    10ps            ±5%             ±1mm
        25 Gbps     4ps            ±3%            ±0.5mm
 16
Connectors and Cables
       PINOUT & POLARIZATION
       POWER PIN PLACEMENT:
          •   Corner pins for mechanical strength
          •   Adjacent pins for high current (parallel paths)
          •   Center pins for sensitive analog supplies
          •   Separate analog and digital supply pins
       GROUND PIN STRATEGY:
          •   Multiple ground pins for low impedance
          •   Ground pins adjacent to high-speed signals
          •   Separate analog and digital grounds
          •   Shield connection to chassis ground
       SIGNAL PIN ASSIGNMENT:
          •   Differential pairs on adjacent pins
          •   High-speed signals away from power switching
          •   Critical signals with dedicated ground returns
          •   Test points for key signals
 17
Connectors and Cables
       ASYMMETRIC HOUSING DESIGN:
           •   Trapezoidal profiles prevent 180° rotation
           •   Chamfered corners indicate proper orientation
           •   Color coding for visual confirmation
           •   Tactile feedback for blind mating
       DEDICATED KEY FEATURES:
           •   Plastic keys in connector housing
           •   Metal guide pins for alignment
           •   Threaded fasteners for retention
           •   Bayonet locks for quick connection
       KEYING IMPLEMENTATION METHODS:
        Keying Type     Advantages      Disadvantages        Applications
        Housing shape Low cost,         Limited config       Simple 2-wire connections
        Removable       Multiple coding Additional part      Modular systems
        Pin presence Many combos Manufacturing complexity High-density connectors
        size            Obvious diff.   Space requirements   Power vs signal
 18
Connectors and Cables
       PIN 1 IDENTIFICATION:
          •   Square pin vs round pins
          •   Colored pin (red for positive)
          •   Larger pin diameter
          •   Corner pin designation
       HOUSING POLARIZATION:
          •   Chamfered corners
          •   Molded alignment features
          •   Color-coded housings
          •   Arrow indicators
       PCB FOOTPRINT POLARIZATION:
          •   Silkscreen indicators
          •   Square pad for pin 1
          •   Asymmetric hole patterns
          •   Reference designator placement
       CABLE ASSEMBLY POLARIZATION:
          •   Keyed connectors on both ends
          •   Wire color coding standards
          •   Cable marking every meter
          •   Unique connector types per function
 19
Connectors and Cables
       BOARD-TO-WIRE DESIGN
       TERMINAL BLOCKS:
          •   Screw terminals for field wiring
          •   Spring clamps for maintenance-free operation
          •   Rising clamps for solid/stranded wire versatility
          •   Push-in terminals for quick assembly
       TERMINAL BLOCK SPECIFICATIONS:
        Terminal Type   Wire Range Current Rating Voltage Rating Applications
        Screw 2.5mm²    0.2-2.5mm² 17A            300V           Control panels
        Spring 4mm²     0.2-4.0mm² 32A            500V           Industrial automation
        Push-in 1.5mm² 0.2-1.5mm² 13A             250V           Building automation
        PCB mount 6mm² 0.5-6.0mm² 41A             630V           Power distribution
       WIRE-TO-BOARD CONNECTORS:
          •   Crimp contacts for reliable connections
          •   Insulation displacement (IDC) for mass production
          •   Solderless terminals for prototyping
          •   Combination power/signal connectors
       DIRECT PCB TERMINATION:
          •   Through-hole solder connections
          •   Surface mount pad termination
          •   Wire bonding for fine pitch
          •   Mechanical strain relief requirements
 20
Connectors and Cables
       MECHANICAL CONSIDERATIONS:
           •   Component height clearance
           •   Mating direction accessibility
           •   PCB thickness compatibility
           •   Mounting hole placement
       ELECTRICAL FOOTPRINT REQUIREMENTS:
           •   Pad size optimization for soldering
           •   Thermal relief connections
           •   Via placement for signal routing
           •   Ground plane continuity
       STANDARD FOOTPRINT DIMENSIONS:
        Connector Family   Pin Pitch Pad Size     Drill Size Applications
        Terminal blocks    5.0-7.5mm 2.0mm diam 1.3mm       Power connections
        Molex KK           2.54mm    1.6mm diam 1.0mm       General purpose
        JST XH             2.5mm     1.4mm diam 0.9mm       Signal connections
        Phoenix COMBICON 5.08mm      2.2mm diam 1.4mm       Industrial control
 21
Connectors and Cables
       PCB MOUNTING METHODS:
          •   Through-hole mounting for mechanical strength
          •   Surface mount for automated assembly
          •   Mixed mounting for optimal performance
          •   Mechanical support posts
       STRESS RELIEF IMPLEMENTATION:
          •   Strain relief boots at cable entry
          •   Cable tie mounting points
          •   Flexible service loops
          •   Mechanical decoupling from PCB
       MOUNTING HARDWARE:
          •   Threaded standoffs for panel mounting
          •   Snap-fit clips for enclosure assembly
          •   Adhesive mounting for non-critical applications
          •   Vibration isolation considerations
 22
Connectors and Cables
       BOARD-TO-BOARD DESIGN
       HEADERS AND SOCKETS:
           •   Standard 2.54mm pitch for prototyping
           •   2.0mm and 1.27mm for higher density
           •   Single and double row configurations
           •   Right-angle variants for space constraints
       STACKING CONNECTOR SPECIFICATIONS:
        Connector Type Pitch   Current Rating Height Range Applications
        Standard header 2.54mm 3A per pin    8-25mm        Development boards
        Mini header     2.0mm 2A per pin     6-20mm        Compact systems
        Micro header    1.27mm 1A per pin    4-15mm        High-density boards
        Board-to-board 0.8mm 0.5A per pin    2-10mm        Mobile devices
       EDGE CONNECTORS:
           •   Card edge design for easy insertion
           •   Gold-plated contacts for reliability
           •   Keying slots for proper orientation
           •   Retention mechanisms for security
       MEZZANINE CONNECTORS:
           •   High-density parallel connection
           •   Controlled impedance design
           •   Power and signal in single connector
           •   Low-profile configurations available
 23
Connectors and Cables
       MATING CYCLE RATINGS:
          •   Development/prototyping: 50-100 cycles
          •   Production testing: 100-500 cycles
          •   Field service: 500-1,000 cycles
          •   High-reliability: 10,000+ cycles
       INSERTION FORCE CONSIDERATIONS:
          •   Manual insertion: 2-10N per contact
          •   Tool-assisted: 10-50N per contact
          •   Automatic assembly: Force feedback control
          •   Extraction force: 50-80% of insertion force
       FORCE CALCULATION:
          •   Total force = Contact force × Number of contacts
          •   Example: 50-pin @ 5N = 250N total
          •   Consider connector housing friction
          •   Design for available insertion equipment
       CONTACT DENSITY OPTIMIZATION:
          •   0.4-0.8mm pitch for high-density applications
          •   Area array contacts for maximum density
          •   Multi-row configurations
          •   Micro-miniature contact technology
       SIGNAL INTEGRITY IN HIGH-DENSITY DESIGNS:
          •   Controlled impedance pathways
          •   Ground contact placement strategy
          •   Power distribution architecture
          •   EMI containment methods
 24
Connectors and Cables
       HARNESS DESIGN
       CABLE BUNDLING STRATEGY:
           •   Group by function (power, signal, data)
           •   Separate high-current from sensitive signals
           •   Maintain consistent bundle diameter
       ROUTING OPTIMIZATION:
           •   Minimize cable length while maintaining service access
           •   Avoid sharp bends and stress concentrations
           •   Provide strain relief at all termination points
       HARNESS ARCHITECTURE TYPES:
        Architecture     Advantages          Disadvantages            Applications
        Point-to-point Simple, reliable Many individual cables       Small systems
        Star topology Centralized control Single point of failure Automotive body control
        Bus topology    Efficient wiring   Protocol complexity     Industrial fieldbus
        Hybrid design     Optimized        Design complexity       Complex systems
 25
Connectors and Cables
       MINIMUM BEND RADIUS GUIDELINES:
          •   Single conductor: 4 × cable diameter
          •   Multi-conductor: 6 × cable diameter
          •   Coaxial cable: 5 × cable diameter
          •   Fiber optic: 10 × cable diameter
       DYNAMIC BEND RADIUS (FLEXING APPLICATIONS):
          •   Continuous flexing: 10-20 × static bend radius
          •   Cycle life dependent on bend radius
          •   Temperature effects on flexibility
          •   Stress concentration at bend points
       STRAIN RELIEF IMPLEMENTATION:
          •   Boot-style strain reliefs for standard cables
          •   Cord grips for panel-mount applications
          •   Service loops for equipment movement
          •   Mechanical decoupling from connectors
 26
Connectors and Cables
       HARNESS DOCUMENTATION REQUIREMENTS:
           •     Schematic diagram with pin assignments
           •     Assembly drawing with routing details
           •     Cable schedule with specifications
           •     Test procedures and acceptance criteria
       WIRE IDENTIFICATION SYSTEMS:
           •     Color coding per application standards
           •     Printed markers at regular intervals
           •     Heat-shrink labels for permanent marking
           •     Cable tags for individual identification
       STANDARD WIRE COLOR CODES:
        Function IPC Standard Aerospace Industrial
        Power (+) Red           Red        Brown
        Power (-) Black         Black      Blue
        Ground      Green       Green      Green
        Signal      Various     Various    Various
       MANUFACTURING SPECIFICATIONS:
           •     Strip length, strand count
           •     Crimp specifications, pull tests
           •     Routing sequence, bundle diameter
           •     Test Continuity, isolation etc.
 27
Connectors and Cables
       TERMINATION TECHNIQUES
       CRIMPING SPECIFICATIONS:
        Gauge Length     Force      Pull   Contacts
        30 AWG 2-3mm 200-400N     4.5kg Micro-miniature
        26 AWG 3-4mm 400-800N     6.8kg      Signal
        22 AWG 4-5mm 800-1200N 11.3kg       Power
        18 AWG 5-6mm 1200-2000N 18.1kg     Hi-Current
       QUALITY FACTORS:
          •   Wire preparation: Proper strip length, strand control
          •   Crimp tool calibration: Force and dimensional control
          •   Contact selection: Wire gauge compatibility
          •   Inspection criteria: Visual and dimensional checks
       SOLDERING TECHNIQUES:
          •   Thermal connection with metallurgical bond
          •   Flux selection for oxidation prevention
          •   Temperature and time control
          •   Joint inspection and rework procedures
       SOLDER JOINT QUALITY:
          •   Wetting angle: <90°
          •   Fillet formation: Concave profile
          •   Intermetallic layer: 1-3μm thickness
          •   Void content: <25% for reliability
 28
Connectors and Cables
       CONNECTOR SELECTION
       VOLTAGE RATINGS:
           •   Working voltage: Maximum continuous operating voltage
           •   Withstand voltage: Short-term overvoltage capability
           •   Breakdown voltage: Insulation failure threshold
           •   Altitude derating: Voltage reduction at high altitude
       CURRENT RATINGS AND DERATING:
           •   Continuous current: Steady-state capability
           •   Peak current: Short-term overload capability
           •   Temperature derating: Current reduction at elevated temperature
           •   Contact resistance: Voltage drop at rated current
       CURRENT DERATING FACTORS:
        Ambient Temperature Derating Factor Altitude Derating Factor
               +23°C              1.00      Sea level     1.00
               +40°C              0.90       3,000m       0.95
               +60°C              0.75       6,000m       0.85
               +80°C              0.60      10,000m       0.70
       INSULATION RESISTANCE:
           •   Minimum values: 1000 MΩ for low-voltage applications
           •   Environmental effects: Humidity, contamination
           •   Measurement conditions: Standard test voltage and time
           •   Aging effects: Degradation over time
 29
Connectors and Cables
       TEMPERATURE PERFORMANCE:
           •    Operating temperature range
           •    Storage temperature range
           •    Thermal shock resistance
           •    Thermal cycling endurance
       VIBRATION AND SHOCK RESISTANCE:
           •    Sine wave vibration: Frequency and amplitude
           •    Random vibration: Power spectral density
           •    Shock resistance: Peak acceleration and duration
           •    Mechanical resonance considerations
       CHEMICAL RESISTANCE:
           •    Fluid compatibility: Oils, solvents, cleaning agents
           •    Corrosion resistance: Salt spray, acidic environments
           •    Outgassing: Space and medical applications
           •    UV resistance: Outdoor applications
       ENVIRONMENTAL TEST STANDARDS:
          Test Parameter    Test Standard    Typical Requirements
        Temperature cycling IEC 60068-2-14 -40°C to +85°C, 100 cycles
               Humidity     IEC 60068-2-78 85°C, 85% RH, 1000 hours
               Vibration    IEC 60068-2-6 10-2000Hz, 10G, 2 hours
                Shock       IEC 60068-2-27    50G, 11ms duration
               Salt spray   IEC 60068-2-11     5% NaCl, 96 hours
 30