EcoStruxure™ Building
www.se.com/buildings
SpaceLogic MP-C Pro
enable rapid identification of the location of the detected error
IP connectivity, flexible network while maintaining communication with the controllers on either
topologies, and support for side of the break.
BACnet/SC applications
The BACnet/IP controllers are based on open protocols that
BACnet/SC (Secure Connect)
simplify interoperability, IP configuration, and device support
management, and can be enabled as BACnet/SC nodes for
The BACnet/IP controllers support BACnet/SC applications as a
increased cybersecurity:
BACnet/SC node. This allows the controllers to be used in a
BACnet/SC network, which allows secure transport of BACnet
• IP addressing traffic and information between BACnet/SC devices over private
• BACnet/IP or BACnet/SC communications and public networks without the need for BBMDs, VLANs, and
VPNs, because the BACnet/SC protocol uses WebSocket
• DHCP for easy network configuration
technology and TLS 1.3 encryption. In addition, BACnet/SC uses
certificate management to help ensure only those devices
The BACnet/IP controllers have a dual-port Ethernet switch,
authorized to be on a BACnet/SC network can operate on that
which enables flexible network topologies:
network.
• Star
• Daisy chain
Models with a versatile mix of I/O
• Rapid Spanning Tree Protocol (RSTP) ring points
MP-C comes in five models with different I/O point count and a
In a star topology, the controller and the parent EcoStruxure BMS versatile mix of I/O point types that match a wide variety of
server are individually connected to an Ethernet switch. Daisy- applications. The universal inputs/outputs are highly flexible and
chain multiple controllers together to reduce installation time and can be configured as either inputs or outputs.
cost. When using a ring network topology, in the event of a
broken IP network or a non-operational controller, RSTP will
Universal I/O 8 10 10 16 20
Type Ub
Universal I/O - - - 4 8
Type Uc
Triac outputs 6 4 8 - -
Relay outputs - 3 - 4 8
Form A
MP-C Display
SpaceLogic Sensor devices
In WorkStation, you update the firmware of multiple BACnet/IP
controllers at the same time and with minimum down time. The The sensor bus provides both power and communications for up
EcoStruxure BMS server keeps track of the installed firmware to to four sensors that are daisy-chained using standard Cat 5 (or
support backup, restore, and replacement of the controllers and higher) cables. The maximum number of sensors that can be
sensors. The server can host controllers of different firmware connected to a controller varies depending on the sensor model
versions. and the combination of cover and sensor base type:
Configurable RS-485 port • Blank covers: Up to four sensors of any combination of sensor
base types
The MP-C controller has one configurable RS-485 port, which
can be configured to support two different types of networks: • 3-button and touchscreen covers:
– Up to two sensor bases with CO2 option
• Sensor bus – Up to four sensor bases without CO2 option
• Modbus network • SpaceLogic LCD temperature sensors: Up to four sensors are
supported
Sensor bus for living space sensors
The maximum total length of the sensor bus is 61 m (200 ft). For
The BACnet/IP controllers provide an interface designed for the
more information, see the SpaceLogic Sensors - SXWS Sensors
SpaceLogic Sensor family of living space sensors. The
for MP and RP IP Controllers - Specification Sheet.
SpaceLogic Sensor devices offer an efficient way to sense the
temperature, humidity, CO2, and occupancy in a room. The
The RS-485 Power Adapter can be used to supply 24 VDC power
SpaceLogic Sensor devices are available with different
to the MP controller sensor bus so that the maximum number of
combinations of sensor types and various covers and user
sensor bases with CO2 option can be increased from two to four
interface options, such as touchscreen, setpoint and override
sensor bases. The adapter can be ordered from Schneider
buttons, and blank covers.
Electric. For more information, see section the RS-485 Adapters
Specification Sheet.
• Maximum of 1,000 Modbus registers per network Using the Commission mobile application, you can connect to
one or many BACnet/IP controllers. You can connect to a single
64-bit Modbus registers are supported, which can be used in BACnet/IP controller using the SpaceLogic Bluetooth Adapter
energy metering. connected to a SpaceLogic Sensor. Using a wireless access
point or a network switch, you can connect to a network of
Maximum total length of the Modbus network is 72 m (236 ft). BACnet/IP controllers on the local IP network.
The Modbus devices require a separate power supply unit. Device configuration
With the Commission mobile application, you can easily discover
Modbus device types BACnet/IP controllers on the IP network. You can change the
configuration of each controller, including the BACnet and IP
Modbus device types are pre-configured Modbus applications
network settings, location, and parent server. To save
for quick and easy Modbus device integration in EcoStruxure
engineering time, you can save common device settings and
Building Operation solutions. For information on the Modbus
then reuse them for controllers of the same model.
devices supported using Modbus device types, see the
document EcoStruxure Building - Modbus Device Integration -
Supported Device Brochure. Field deployment and I/O checkout
The Commission mobile application does not require an
EcoStruxure BMS server or a network infrastructure to be in
Commission mobile application place. You can use the mobile application to load the controller
The Commission mobile application is designed for local application directly into the local BACnet/IP controller and deploy
configuration, field deployment, and commissioning of BACnet/IP the controller. The controller application can be created offline
controllers. The mobile application reduces the commissioning using Project Configuration Tool or WorkStation. You can also
time, allows flexibility in project execution, and minimizes perform an I/O checkout to verify that the controller's I/O points
dependencies on network infrastructure. are configured, wired, and operating correctly.
• WorkStation/WebStation interface
• Script and Function Block programming options
• Device discovery
• Engineering efficiency
Device discovery
The enhanced Device Discovery in WorkStation enables you to
easily identify BACnet/IP controllers on a BACnet network and to
associate the controllers with their parent server.
Engineering efficiency
The engineering and maintenance of BACnet/IP controllers can
be done very efficiently using the EcoStruxure Building Operation
reusability features. With these features, you can create library
items (Custom Types) for a complete controller application that
contains programs and all necessary objects such as trends,
alarms, and schedules. The controller application in the Custom
Types library is reusable across all controllers of the same
model. You can use the controller application as a base for
creating new controllers intended for similar applications. You
can then edit the controller application, and the changes are
automatically replicated to all controllers, while each controller Download page for preconfigured BMS applications
keeps its local values.
MP-C-15A SXWMPC15A10001
MP-C-18A SXWMPC18A10001
MP-C-18B SXWMPC18B10001
MP-C-24A SXWMPC24A10001
MP-C-36A SXWMPC36A10001
a
MP-C-15A-BAA SXWMPC15A10A01
MP-C-18A-BAAa SXWMPC18A10A01
a
MP-C-18B-BAA SXWMPC18B10A01
MP-C-24A-BAAa SXWMPC24A10A01
a
MP-C-36A-BAA SXWMPC36A10A01
MP-C-15A-SMKb SXWMPC15A1S001
b
MP-C-18A-SMK SXWMPC18A1S001
MP-C-18B-SMKb SXWMPC18B1S001
b
MP-C-24A-SMK SXWMPC24A1S001
MP-C-36A-SMKb SXWMPC36A1S001
a) Buy American Act (BAA) compliant. MP-C-15A-BAA and MP-C-36A-BAA are also included in BAA compliant bundles that include either the MP-C-15A-BAA controller
and MP-C-BAA DISPLAY or the MP-C-36A-BAA controller and MP-C-BAA DISPLAY. The bundles can be ordered using the part number SXWMPC15AB10A01 for the
MP-C-15A-BAA bundle or SXWMPC36AB10A01 for the MP-C-36A-BAA bundle.
b) Approved for use in UL 864 smoke control systems. The smoke control (SMK) models are shipped with a validated UL 864 software version, which can differ from the
latest released software. For information on the approved software revisions for the device when used in UL 864 smoke control systems, see the Smoke Control System
Approved Software Revisions - EcoStruxure Building Management document, 01-16001-XX-en.
Specifications
SpaceLogic MP-C Pro
AC input
Frequency 50/60 Hz
DC input
Environment
Material
Mechanical
Dimensions (MP-C-15A, -18A, -18B) 153 W x 110 H x 64 D mm (6.0 W x 4.3 H x 2.5 D in.)
110 44
(4.3) (1.7)
122
(4.8)
44 (1.7)
mm 64 (2.5)
(inches)
234 (9.2) 50 (2.0)
110 44
(4.3) (1.7)
122
(4.8)
44 (1.7)
Weight, MP-C-15A
Including terminal blocks 0.358 kg (0.789 lb)
Weight, MP-C-18A
Including terminal blocks 0.371 kg (0.818 lb)
Weight, MP-C-18B
Including terminal blocks 0.361 kg (0.796 lb)
Weight, MP-C-24A
Including terminal blocks 0.495 kg (1.091 lb)
Weight, MP-C-36A
Including terminal blocks 0.547 kg (1.206 lb)
Compatibility
Agency compliances
Emission RCM; BS/EN 61000-6-3; BS/EN IEC 63044-5-2; FCC Part 15, Sub-part B, Class B
Safety standards BS/EN 60730-1; BS/EN 60730-2-11; BS/EN IEC 63044-3; UL 916 C-UL US Listed
Real-time clock
Communication ports
Communications
CPU
Removable No
17
46 (0.7)
(1.8)
Digital inputs
Range Dry contact switch closure or open collector/open drain, 24 VDC, typical wetting current 2.4 mA
Range Dry contact switch closure or open collector/open drain, 24 VDC, typical wetting current 2.4 mA
Maximum frequency 25 Hz
Supervised inputs
5 V circuit, 1 or 2 resistors
Monitored switch combinations Series only, parallel only, and series and parallel
Voltage inputs
Range 0 to 10 VDC
Resolution 1.0 mV
Current inputs
Range 0 to 20 mA
Resolution 1 μA
Impedance 47 ohm
Resistive inputs
Supported thermistors
Honeywell 20 kohm
Balco 1 kohm
Measurement accuracy
20 kohm -50 to -30 °C: +/-1.5 °C (-58 to -22 °F: +/-2.7 °F)
-30 to 0 °C: +/-0.5 °C (-22 to +32 °F: +/-0.9 °F)
0 to 100 °C: +/-0.2 °C (32 to 212 °F: +/-0.4 °F)
100 to 150 °C: +/-0.5 °C (212 to 302 °F: +/-0.9 °F)
10 kohm, 2.2 kohm, and 1.8 kohm -50 to -30 °C: +/-0.75 °C (-58 to -22 °F: +/-1.35 °F)
-30 to +100 °C: +/-0.2 °C (-22 to +212 °F: +/-0.4 °F)
100 to 150 °C: +/-0.5 °C (212 to 302 °F: +/-0.9 °F)
Linearized 10 kohm -50 to -30 °C: +/-2.0 °C (-58 to -22 °F: +/-3.6 °F)
-30 to 0 °C: +/-0.75 °C (-22 to +32 °F: +/-1.35 °F)
0 to 100 °C: +/-0.2 °C (32 to 212 °F: +/-0.4 °F)
100 to 150 °C: +/-0.5 °C (212 to 302 °F: +/-0.9 °F)
Pt1000
Ni1000
LG-Ni1000
Voltage outputs
Range 0 to 10 VDC
Resolution 10 mV
Load range -1 to +2 mA
Range 0 to 20 mA
Accuracy +/-0.2 mA
Resolution 21 µA
Relay outputs, DO
Channels, MP-C-15A 0
Channels, MP-C-18B 0
Channels, MP-C-18B 0
Channels, MP-C-24A 0
Channels, MP-C-36A 0
Triac outputs, DO
Channels, MP-C-24A 0
Channels, MP-C-36A 0
Commons COM1 for DO1 and DO2 (on MP-C-15A, -18A, -18B)
COM2 for DO3 and DO4 (on MP-C-15A, -18A, -18B)
COM3 for DO5 and DO6 (on MP-C-15A, -18B)
COM4 for DO7 and DO8 (on MP-C-18B only)
The common terminals can be connected to 24 VAC or to ground.
Triac output protection MOV and snubber across each triac output
MOV from triac COM to ground
MP-C-15A
MP-C-18A
MP-C-18B
MP-C-24A
MP-C-36A
a) The SpaceLogic resistive temperature sensor (SLA...) is designed to be connected to I/O points/terminals on RP or MP controllers, or I/O modules. The sensor requires
an analog input (temperature input).
Regulatory Compliance Mark (RCM) - Australian Communications and Media Authority (ACMA)
This equipment complies with the requirements of the relevant ACMA standards made under the WEEE - Directive of the European Union (EU)
Radiocommunications Act 1992 and the Telecommunications Act 1997. These standards are This equipment and its packaging carry the waste of electrical and electronic equipment (WEEE)
referenced in notices made under section 182 of the Radiocommunications Act and 407 of the label, in compliance with European Union (EU) Directive 2012/19/EU, governing the disposal
Telecommunications Act. and recycling of electrical and electronic equipment in the European community.
UK Conformity Assessed UL 916 Listed products for the United States and Canada, Open Class Energy Management
S.I. 2016/1091 - Electromagnetic Compatibility Regulations 2016 Equipment. UL file E80146.
S.I. 2016/1101 - Electrical Equipment (Safety) Regulations 2016
S.I. 2012/3032 - Restriction of the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment Regulations 2012
S.I. 2013/3113 - Waste Electrical and Electronic Equipment Regulations 2013 UL 864 Listed products for the United States. 10th Edition Smoke Control System. UL file S5527.
This equipment complies with the rules, of the UK regulations, for governing the UKCA Marking
for the United Kingdom specified in the above directive(s).
www.se.com/buildings
© 2024 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
03-60035-02-en March 2024