Cat UK CA2009 p3
Cat UK CA2009 p3
LAN tester
C.A 7028
> Detects, identifies and locates faults from up to 150 m
away
> Alphanumeric and graphical screen
> Large number of standards supported (TIA 568, ISO, EN,
USOC, ISDN)
C.A 7028
Specifications
Type of cable RJ 45
Tests Cut wires, short-circuit, crossed,
separated, split or reversed pairs,
shielding faults
Remote modules Identifiers nos. 1 to 9
Dimensions 165 x 90 x 37 mm
Weight 350 g
> For the C.A 7028: > C.A 7028 delivered with 2 x RJ45 leads,
Set of 4 identifiers nos. 2 to 5 > P01101994 1 identifier No. 1 and carrying case, 1 operating
Set of 4 identifiers nos. 6 to 9 > P01101995 manual in 5 languages and 1 battery
Cable tone tracer
Carrying bag > P01298532
Reference to order
Portable, on-site and laboratory test and measurement instruments 2009 catalogue Page 79
RADIOFREQUENCY AND MICROWAVE MEASUREMENTS
Wattmeter / reflectometers
RW 511, RW 5012, RW 501 & RW 521
> Wattmeters developed for military and civilian applications:
Simple installation testing
Testing of the assembly comprising the transmitter, cable and
antenna / audio circuit
1 product for each market:
• Single side-band transmission (RW 511)
• VHF networks, police, emergency services (RW 5012)
• Radio, FM and TV networks (RW 501)
• Rural VHF – HF networks (RW 521)
> RW511: delivered with a 9 V battery and an operating manual in > For the RW 511, RW 5012, RW 501 and RW 521:
5 languages Carrying bag > P01298046
> RW 5012, RW501and RW521: delivered with 2 x 1.5 V SWR chart for RW 501, 511 & 5012 > P01255901
batteries and an operating manual in 5 languages SWR chart for RW 521 > P01255902
References to order
Page 80
Fieldmeters
C.A 40
State at delivery
Portable, on-site and laboratory test and measurement instruments 2009 catalogue Page 81
RADIOFREQUENCY AND MICROWAVE MEASUREMENTS
LF fieldmeters
C.A 42
> Measurement of the fields and comparison
with the international standards
Measurement of Low-Frequency magnetic and electrical fields
Oscilloscope and frequency analysis functions
Isotropic probes
C.A 42
Specifications
Magnetic field measurement MF 400 – MF 400H – MF 05 isotropic probes:
10 nT to 1 T*
Electrical field measurement EF 400 isotropic probe: 1 V/m to 30 kV/m
Frequency range DC at 400 kHz*
Evaluation standards stored 6 as standard including ICNIRP
Probes 1 internal isotropic probe
and 4 external isotropic probes as an option
Outputs RS232 and analogue output
Functions Option: oscilloscope, frequency analysis
Dimensions 266 x 144 x 60 mm
Weight 950 g
*depending on the isotropic probe used
Page 82
Training benches: guided propagation
Education 1
Experiments*
Studies in guided mode Set Reference Accessories
GUNN oscillator
Frequency
Wavelength BDH R100 > P01275101
Standing-wave ratio
Detector quadratic law
Impedance and matching movable impedance
BDH R100 > P01275101 adapter LAZ 100 > P01275352
Attenuation BDH R100 > P01275101 Calibrated attenuator ATC 100 > P01275339
Power milliwattmeter MH 600 and > P01250101
BDH R100 > P01275101 + probe ST613 > P01285101
Coupling and directionality Cross guide and GCX 100/20 > P01275305
BDH R100 > P01275101 directional couplers and CDT 100/20 and > P01275341
Isolator and circulator CIR 100 > P01275344
BDH R100 > P01275101 circulator and isolator ISO 100 and > P01275308
Dielectrics BDH R100 > P01275101 dielectrics kit KED 100 > P01275353
* It is advisable to use the GUNN CF204 power supply to power the GUNN-diode oscillators in total safety
Accessories / Spares
Portable, on-site and laboratory test and measurement instruments 2009 catalogue Page 83
RADIOFREQUENCY AND MICROWAVE MEASUREMENTS
Wave polarization
Training benches
Education
MH 600
ANF 100
on rotating platform
on experimentation support
Experiments*
Studies in
free-space Kit Reference Accessories
propagation mode**
Polarization and space
E ANC 100 > P01275365
attenuation
Horn antenna E ANC 100 > P01275365
Parabolic antenna E ANP 100 > P01275366
Slot antenna E ANF 100 > P01275367
Dielectric antenna E AND 100 > P01275368
Patch antenna E ANP 100 > P01275370
Passive radar responder E RRL 100 > P01275371
DOPPLER effect Displacement
E DOP 100 > P01275374 simulator SDD 100 > P01275363
* It is advisable to use a GUNN CF204 power supply to power GUNN diode oscillators in total safety
** These experiments require the use of a BEM100 Emission Bench > P01275364
Accessories / Spares
Page 84
LABORATORY AND EDUCATIONAL INSTRUMENTATION
Training case
C.A 6710
C.A 6710
Specifications
Standards illustrated NF C 15-100, VDE 0100, IEE 16th, IEC 64-8,
ÖVE EN-1, RBT MIE, NIN/NIV, etc.
SLT simulations T, TN and IT
Measurement simulations Earth, resistivity, earth and phase/neutral loops,
insulation, RCD tests (30 mA / 300 mA),
current / leakage current
Fault simulations Phase/neutral or earth interruptions,
neutral/earth reversal, leakage current
Electrical safety Cat. II 230 V
Dimensions 490 x 395 x 195 mm
Weight 10 kg
Choice of current sensors: AmpFLEXTM, MN clamps, etc.: > C.A 6710 electrical installations training case.
please contact us Delivered with a 2P+E FRA/GER Schuko-type mains power cable
6 black safety leads 25 cm long with rear connector,
universal adapter for mains socket, FRA/GER adapter
for mains socket and operating manual in 2 languages.
Reference to order
Portable, on-site and laboratory test and measurement instruments 2009 catalogue Page 85
LABORATORY AND EDUCATIONAL INSTRUMENTATION
Training case
Power and Harmonics case
> Power and Harmonics case
* on phase 1
> Delivered with mains lead > Choice of current sensors: AmpFLEXTM, MN clamps, etc.:
please contact us
Reference to order
Page 86
Current sensors for oscilloscopes
Probes
MN60
Dimensions 135 x 51 213 x 66 216 x 111 310 x 120 231 x 67 224 x 97 236.5 x 97
(overall) x 30 mm x 34 mm x 45 mm x 48 mm x 36 mm x 44 mm x 44 mm
Weight 180 g 420 g 550 g 1200 g 330 g 440 g 520 g
Power supply 1 pile 9 V
References to order
PAC22
E3N PAC12
Portable, on-site and laboratory test and measurement instruments 2009 catalogue Page 87
LABORATORY AND EDUCATIONAL INSTRUMENTATION
Analogue testers
C.A 400 Series
> Economical and rugged for training applications
> Electrical safety compliant with IEC 61010-1
Resistant casing with fold-away stand
Single switch
Safety sockets
Dual insulation
C.A 401 C.A 402 C.A 403 C.A 404 C.A 405 C.A 406
Null galvanometer Multimeter with 6 black,
Function Single-phase AC/DC Single and three-phase
AC/DC ammeter AC/DC voltmeter 2 black scales green and red scales
wattmeter AC/DC wattmeter
(0 to 30 and 0 to 100)
Switchgear Magneto-electric rectifying Magneto-electric Ferrodynamic Magneto-electric
Calibres 6 single-phase cal.: 8 DC cal.:
Voltage 8 DC cal.:
1 DC cal.: 1 DC cal.: 4 cal.: 60 V to 480 V 100 mV to 1,000 V
100 mV to 1,000 V
100 mV for shunts 100 mV for shunts 60 V to 480 V 4 balanced three-phase 6 AC cal.: 3 V to 1,000 V
6 AC cal.: 3 V to 1,000 V cal.: 60 V√3 to 240 V√3
11 DC cal.: 4 DC cal.: 1 mA to 1 A
Intensity 100 ΩA to 10 A 2 DC cal.: + 1 cal. 50 ΩA
30 ΩA, 3 mA 2 cal.: 0.5 A; 1 A 1 cal.: 5 A 5 AC cal.: 0.3 mA to 3 A
7 AC cal.:
10 mA to 10 A + 1 cal. 150 ΩA
Resistance 3 cal.: 0.5 Ω - 1 kΩ to 1 MΩ
Basic accuracy 2 % DC 2.5 % DC, 1 % single-phase 1.5 % DC
1.5 % DC 1 % AC
2.5 % AC AC and 2 % three-phase AC
Operating
frequency 45 to 400 Hz 20 to 400 Hz 0 to 500 Hz 15 to 500 Hz 20 to 400 Hz
Fuses 3.15 A HRC and
Internal resistance:
1 A HRC and 160 mA HRC
20 kΩ/DC; 315 mA HRC 1.25 A HRC 6.3 A HRC
10 A HRC Int. res.: 20 kΩ/VDC ;
6.32 kΩ/AC 6.32 kΩ/VAC
Dimensions 165 x 105 x 50 mm
Weight 450 g
> C.A 401 delivered with a 1.5 V battery (LR6) > P01170301
> C.A 402 delivered with a 1.5 V battery (LR6) > P01170302
> C.A 403 delivered with a 1.5 V battery (LR6) > P01170303
> C.A 404 delivered with a 1.5 V battery (LR6) > P01170304
> C.A 405 delivered with a 1.5 V battery (LR6) > P01170305
> C.A 406 delivered with test-probe leads
and a 1.5 V battery (LR6) > P01170501
> C.A 406 kit version > P01170701
Page 88
Decade boxes and shunts
Resistance boxes
References to order
Specifications
0.1 to 1 Ω P03197521A
1 to 10 Ω P03197522A
10 to 100 Ω P03197523A
100 to 1,000 Ω P03197524A
1 to 10 kΩ P03197525A
10 to 100 kΩ P03197526A
100 to 1,000 kΩ P03197527A
1 to 10 MΩ P03197528A
BR 04:
4 decades, 1 Ω to 10 kΩ P01197401
BR 05:
5 decades, 1 Ω to 100 kΩ P01197402
BR 06:
6 decades, 1 Ω to 1 MΩ P01197403
BR 07:
7 decades, 1 Ω to 10 MΩ P01197404
References to order
Specifications
7-ratio K box P03197531A
Zero galvanometer P03197611A
Dual switch box P03197529A
Simple changeover-switch box P03197530A
Portable, on-site and laboratory test and measurement instruments 2009 catalogue Page 89
LABORATORY AND EDUCATIONAL INSTRUMENTATION
References to order
Specifications
0.01 to 0.1 µF P03199613A
0.1 to 1 µF P03199612A
1 to 10 µF P03199611A
BC 05:
5 decades, 0.1 nF to 10 µF P01197421
Inductance boxes
Reference to order
Specifications
BL 07:
7 decades, 1 µH to 10 H P01197421A
References to order
Specifications
1A HA 001
5A HA 005
10 A HA 010
20 A HA 020
30 A HA 030
Page 90
CURRENT MEASUREMENT
2x
1x
PAC
LEX
PAC
EN
AmpF
B1XX
K
C1XX
DN
YN
MN
MINI
For intensities
Clamping diameter (mm) 10 20 30 52 64 100 380 3.9 8 30 39
AC ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
DC ■ ■ ■ ■
Min 5 mA 10 mA 1A 1 mA 100 mA 500 µA 500 mA 100 µA 5 mA 200 mA 200 mA
MAX 150 A 240 A 600 A 1,200 A 3,600 A 400 A 10,000 A 4.5 A 150 A 600 A 1,000 A
Output
in mA AC ■ ■ ■ ■ ■
in mV AC ■ ■ ■ ■ ■ ■ ■
in mV DC ■ ■ ■
in mV AC+DC ■ ■ ■ ■
Connection
Insulated Ø 4 mm sockets ■ ■ ■
Lead with insulated elbowed ■ ■ ■ ■ ■ ■ ■ ■ ■
with Ø 4 mm plugs
Insulated Ø 4 mm plug box ■ ■
with standard 19 mm spacing
Coaxial cable with ■ ■ ■ ■ ■ ■ ■
insulated male BNC
Single-calibre ■ ■ ■ ■ ■
Multi-calibre ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
For multimeter ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
For oscilloscope ■ ■ ■ ■ ■ ■ ■ ■
For seeking leaks ■ ■ ■ ■
and insulation faults
For measuring power values, ■ ■ ■ ■ ■ ■ ■
harmonics, etc.
For the process and the 4-20/ ■
0-20 mA measurement loop
Power supply
Stand-alone ■ ■ ■ ■ ■ ■
9 V battery ■ ■ ■ ■ ■
Mains adapter ■ ■ ■ ■ ■
Page 95 95 95 95 95 95 97 96 96 96 96
Portable, on-site and laboratory test and measurement instruments 2009 catalogue Page 91
CURRENT MEASUREMENT
Current sensors
Choose
Page 92
Ammeter clamps
Portable, on-site and laboratory test and measurement instruments 2009 catalogue Page 93
CURRENT MEASUREMENT
Current measurement
Input Output / Connections Specific features
s
ltage
ift)
Measurement range (1)
ase sh
vervo
s)
)
scope
mm(2
ow ph
)
inst o
in Hz
4 mm
scillo
ent (l
gø4
d aga
ency
put) tio
C zero
a
ctor (o
kets ø
surem
ty plu
tion r
rent
racy
(frequ
rent
tecte
Leak current
atic D
w cur
l accu
m cur
t
forma
le soc
+ safe
onne
urren
ut pro
r mea
rrent
t/out
with
measurement
e
nt
Autom
Very lo
DC
a
g
Mediu
BNC c
AC
Fema
Low c
Ho cu
Powe
Trans
Curre
Typic
Band
(inpu
Outp
Volta
Lead
Series Model To
order
10 mA to 2.4 A 2 V AC 1 A/1000 mV 40 Hz to ≤ 1%
MN73 100 mA to 240 A 2 V AC 1 A/10 mV 10 kHz ≤ 2% > P01120421
Measurement on oscilloscope
0.1 to 60 A peak 2 V AC 1 A/100 mV 40 Hz to ≤ 2%
MN60 0.5 to 600 A 2 V AC 1 A/10 mV 40 kHz ≤ 1.5%
> P01120409
peak
1 A to 1200 A 5 Hz to
Y7N peak
1 V AC 1 mA/1 mV
10 kHz
≤ 2% > P01120075
50 mA to 10 A peak 1 A/100 mV DC to ≤ 3%
E3N 1 to 100 A peak 1 V peak
1 A/10 mV 100 kHz ≤ 4%
> P01120043A
0.2 to 60 A peak
PAC1 0.4 to 60 A DC 600 mV AC/DC
1 A/10 mV DC to ≤ 1.5% > P01120072
2 0.5 to 600 A peak 1 A/1 mV 10 kHz ≤ 2%
0.5 to 600 A DC
(1) The upper value corresponds to 120% of the maximum nominal value. (2) Lead + electronic unit with Ø 4 mm safety connectors, centre distance 19 mm, for K series
Page 94
Input Output / Connections Specific features
Current
ltage
Measurement range (1)
) ift
ase sh
overvo
es)
4 mm (2)
measurement AC
oscop
(low ph
in Hz)
4 mm
gainst
o
ill
n rati
plug ø
uency
tor (osc
C zero
t
remen
kets ø
racy
ent
cted a
nt
(inpu ormatio
q
curre
w curr
ith (fre
l accu
+ safety
atic D
measu
onnec
rrent
ut)
rrent
le soc
t prote
t/outp
m
ge
nt
lo
Bandw
u
Autom
a
DC
Hot cu
Transf
Mediu
BNC c
AC
Low c
Power
Fema
Typic
Curre
Volta
Outpu
Leads
Very
To
Series Model Order
MN039 . to
. to
> P01120408
MN060 . to
. to
peak
peak .
> P01120409
C100 . to .
> P01120301
31 mm
C112 to . > P01120314
. to peak peak
111 mm C160 . to
to
peak
peak
peak
peak
> P01120308
Ø 100 mm max to . .
. to .
C173 . to .
> P01120309
to .
43 mm to
312 mm B102 to
> P01120083
310 mm
D35N to
to
. .
.
> P01120054A
to peak
310 mm D38N to
to
peak
peak .
> P01120057A
(1) The higher value corresponds to 120% of the max. nominal value (2) Reshaping of AC signal by diodes.
Portable, on-site and laboratory test and measurement instruments 2009 catalogue Page 95
CURRENT MEASUREMENT
ge
Measurement range (1)
rvolta
shift)
)
st ove
mm(2
)
copes
phase
Hz)
again
cy in
scillos
4 mm
gø4
t (low
t/outp n ratio
equen
C zero
ty plu
remen
ected
tor (o
kets ø
racy
rent
rent
ut)
io
w cur
ith (fr
l accu
atic D
t
+ safe
measu
t prot
onnec
t
m cur
forma
rrent
le soc
urren
e
nt
lo
Bandw
Autom
a
DC
g
Hot cu
Outpu
Mediu
BNC c
AC
Leads
Low c
Power
Trans
Fem a
Typic
(inpu
Curre
Volta
Very
To
Ø 3.9 mm Series Model Order
to . .
15 mm to
111 mm K1 > P01120067
to . peak peak
to
K2 to . > P01120074
to peak peak
25 mm
. to
67 mm
E1N . to . . > P01120030A
. to .
231 mm
. to peak
E3N to peak
peak > P01120043A
to
Ø 11.8 mm 20 mm E6N to . . > P01120040A
to .
50 x 10 mm
or Ø 30 mm . to
26 mm
PAC10 . to
> P01120070
224 mm
. to
. to .
PAC11 . to
> P01120068
. to
. to peak
to .
.
PAC12 . to peak
> P01120072
. to
97 mm
50 x 12.5 mm
. to
or Ø 39 mm 20 mm PAC20 . to
. > P01120071
. to
224 mm . to .
PAC21 . to . > P01120069
. to .
. to peak
.
. to
PAC22 . to peak
. > P01120073
.
. to
97 mm
(1) The higher value corresponds to 120 % of the max. nominal value
(2) Lead + electronic housing with Ø 4 mm safety plugs,
centre distance 19 mm, for K series.
Page 96
AmpFLEX TM Flexible current sensors
ltage
Measurement range (1)
ift)
ase sh
overvo
es)
4 mm (2)
oscop
(low ph
in Hz)
4 mm
gainst
o
ill
n rati
plug ø
uency
tor (osc
C zero
t
remen
kets ø
racy
ent
cted a
nt
(inpu ormatio
q
curre
w curr
ith (fre
l accu
+ safety
atic D
measu
onnec
rrent
ut)
rrent
le soc
t prote
t/outp
m
ge
nt
lo
Bandw
u
Autom
a
DC
Hot cu
Transf
Mediu
BNC c
AC
Low c
Power
Fema
Typic
Curre
Volta
Outpu
Leads
Very
To
Models order
20A/200A (45 cm) 0.5 … 20A 1A / 100mV > P01120503
0.5 … 200A 2 V AC 1A / 10mV 10 … 20kHz ≤ 1 %
The range is composed of 9 standard models* processing electronics and a standard 9 V bat- the core makes it easy to handle even with
dedicated to the measurement of AC currents tery. The distance between the sockets (19 mm) safety gloves.
from 0.5 A to 10 kA, at industrial frequencies. facilitates direct connection to any type of mul- Other strong points: very lightweight (no mag-
Each flexible core (48, 80 or 120 cm long timeter, tester or recorder equipped with an AC netic circuit), no saturation effect, highly accu-
depending on the model) is connected by a voltage input (impedance Z > 1 MΩ). rate and very little phase shift (for wattmeter
shielded cable to a small box containing the The quick and simple system for opening/closing measurements).
AmpFLEXTM
1 kA / 10 kA
20 A / 200 A
* Specific models on request: consult us concerning the possible > Bring unlimited autonomy to your AmpFLEX™:
sensitivities (mV/A) and lengths. We can also supply bare sensors replace the battery with the mains adapted plug
for incorporation in assemblies including the signal processing Adaptator for AmpFLEXTM > P01101968
electronics.
-+
Portable, on-site and laboratory test and measurement instruments 2009 catalogue Page 97
MEASUREMENT ACCESSORIES
References to order
Dimensions
Cases
270 x 195 x 65 mm * P01298071
320 x 255 x 75 mm * P01298004
440 x 310 x 135 mm * P01298072
Hard cases
272 x 248 x 130 mm * P01298068
272 x 248 x 182 mm * P01298069
Carrying cases
References to order
Dimensions
Carrying cases
470 x 290 x 240 mm P01298025
480 x 380 x 260 mm P01298026
240 x 230 x 70 mm P01298033
260 x 160 x150 mm P01298006
300 x 260 x 120 mm P01298045
360 x 210 x 200 mm P01298061
385 x 260 x 240 mm P01298056*
P01298034*
520 x 230 x 170 mm P01298044
220 x 180 x 75 mm P01298036
References to order
Dimensions
Shoulder bags
230 x 140 x 130 mm P01298049
240 x 160 x 90 mm P01298032
260 x 205 x 65 mm P01298055
250 x 190 x 80 mm P01298051
180 x 75 x 45 mm P01298012
265 x 125 x 60 mm P01298043
220 x 120 x 70 mm P01298048
185 x 135 x 85 mm P01298046
210 x 120 x 30 mm P01298532
185 x 70 x 30 mm P01298007
Page 98
Specimen bags for portable instruments
Portable, on-site and laboratory test and measurement instruments 2009 catalogue Page 99
MEASUREMENT ACCESSORIES
Page 100
3
26 6
13
4
12 9
17
18
8
11
10
16 20
15
26
19
25
24
21
22 23
Portable, on-site and laboratory test and measurement instruments 2009 catalogue Page 101
MEASUREMENT ACCESSORIES
Selected accessories
Leads
IP2X leads IP2X test probe Ø 4 mm 600 V CAT IV 1 red / 1 black P01295284Z
Elbowed male plug Ø 4 mm 1,000 V CAT III
15 A 1.5 m
IP2X leads C.A 704, C.A 760 & C.A 765 600 V CAT IV 1 red / 1 black P01295285Z
IP2X test probe Ø 4 mm 1,000 V CAT III
Elbowed female connector
Ø 4 mm
15 A / 0.25 m & 0.85 m
Standard Straight male plug Ø 4 mm 600 V CAT IV 1 red / 1 black P01295288Z
PVC leads Straight male plug Ø 4 mm 1,000 V CAT III
Standard Male plugs Ø 4 mm with rear 600 V CAT III 1 red / 1 black P01295290Z
PVC leads connector
Page 102
Selected accessories
Kits
Portable, on-site and laboratory test and measurement instruments 2009 catalogue Page 103
INDEX BY FUNCTION
Aa Ee Mm Ss
Accessories: Earth measurements Measurement leads:
• protection and transport P.8, 17, 22, 23, 52 • with banana plugs, Sensors:
accessories P.98 - 101 Education (measurement instru- test probes, etc. P.102 - 103 • current sensors P.92 - 94
• test accessories (wire-grips, ments) P.85 to 90 Megohmmeters (see insulation • temperature sensors P.69
crocodile clips, terminal lugs, Electrical equipment testers testers) P.33 - 38 Shock-proof protective sheath
test probes) P.102 - 103 P.47 - 50 Micro-ohmmeter P.46 P.98
• oscilloscope accessories Electrical installation testers Microwave measurement Short-circuit location P.79
P.87 P.29 - 32 P.80 - 84 Software:
Accessory kits P.99 Electromagnetic disturbance Milliohmmeters P.46 • energy analyser software P.60
Air (temperature sensors) analysers P.81 - 82 Multifunction testers Soil resistivity measurement
P.69 - 70 Electromagnetic field P.31 – 32, 75 P.39, 41 - 44
Ampflex P.97 measurement P.81 - 82 Multimeter accessories Sound-level meters P.77
Analysers: Energy measurement, analysis P.99 - 100 Surface temperature sensors
• electrical energy P.51-59 & management P.51 - 60 Multimeters: P.67 - 69
• electromagnetic disturbances • analogue P.13 - 14
P.81 - 82 Ff • analogue/digital P.15 Tt
• power P.51 - 59 Field measurement P.81 - 82 • digital P.16 - 19 Telephone line measurement
Anemometers P.73 Fieldmeters P.81 - 82 • clamp-on P.21 - 24 P.79
Artificial neutral box P.21 Flexible coil Multitesters P.9 - 12 Temperature measurement
(current sensor) P.97 P.61 - 70
Bb Flexible current sensors P.97 Oo Temperature sensor P.69
Bags P.98 Free-space propagation Oscilloscope current probes Teslameter P.81
mode studies P.83 - 84 P.87 Test probes P.102 - 103
Cc Testers:
Cable and cabling testers P.79 Gg Pp • loop testers P.29 – 32, 45
Cable locators P.79 Gas detector P.78 Phase identification, phase • RCD testers P.9 – 12, 29
Cables (see measurement Gaussmeter P.81 - 82 detection, phase order testers • electrical equipment testers
leads) P.99 - 100 Guided propagation P.9 - 12 P.47 - 50
Calibrators P.20 mode studies P.83 - 84 Phase rotation • earth testers
Carrying cases P.98 P.9 – 11, 22 – 24, 29 - 32 P.29 - 30, 39 - 45
Clamp transformer P.92 - 93 Hh Phase shift measurement • insulation testers P.33 - 38
Clamps: Hall-effect clamps P.92 - 93 P.51 - 59 • electrical installation testers
• Hall-effect clamps P.92 - 93 Harmonics clamps P.25 Photoelectric cells P.29 – 32
• ammeter clamps P.92 - 93 Humidity detectors P.72 (light measurement) P.76 • phase order tester P.49
• current measurement clamps Hygrometric measurement P.72 Physical measurement • resistivity testers P.39, 41 - 44
P.92 - 93 probes P.69 - 70 • multifunction testers P.31 – 32
• earth clamps P.39, 45 Ii Portable ammeters P.92 - 93 • voltage testers P.9 – 11
• harmonics clamps P.25 Infrared cameras P.61 - 63 Portable voltmeters P.9 - 19 • cable testers P.79
• multimeter clamps P.21 - 24 Infrared thermometers P.61 - 66 Power factor measurement Thermo-anemometer P.73
• leakage current clamps P.27 Insulated current probes P.22, 23, 51 to 59 Thermocouples P.69
• transformer clamps P.54 P.92 - 93 Power measurement Thermography P.62 - 63
Continuity testing P.10 - 49 Insulation faults P.33 - 38 P.51 - 60, 86 Thermo-hygrometers P.72
Crocodile clips P.99 Insulation resistance Probes for oscilloscopes P.87 Training benches P.83 - 84
Current measurement P.91 - 97 measurement P.33 - 38 Process current measurement Transport (cases, hard cases,
Current transformer secondary IP2X leads and clamp P.94 bags) P.98
measurement P.92 - 93 probes P.99 – 100 Protection (cases, hard cases, Transport cases P.98
Cut cable location P.79 bags) P.98 - 101
Kk Vv
Dd Kelvin clamp P.46 Rr Varmeters P.51 - 59
Data acquisition P.97 Radiofrequency measurement Voltage absence tester (VAT)
Data recording P.54 - 60 Ll P.80 to 84 P.9 - 11
Decade boxes (resistance, Laboratory measurement Ratiometer P.49
capacitance) P.89 - 90 instruments P.85 - 90 RCD testers P.12, 29 - 32 Ww
Detectors: Laboratory shunts P.90 Reflectometers P.79 Wattmeters P.51 – 59, 88
• fault detectors LAN testers P.79 Resistance: Wire-grips P.99 - 100
(cuts, short-circuits) P.79 Laser: • decade boxes P.89 - 90
• humidity detectors P.71 - 72 • thermometer sight P.61 - 66 • earth resistance Zz
• gas detectors P.78 Leakage current measurement P.29 – 32, 40 – 41, 45 Zero galvanometer P.88 - 89
• voltage detectors P.9 - 12 clamp P.27, 39, 45 • insulation resistance P.33 - 38
Digital ohmmeters P.40 – 41, 45 Lighting measurement P.76 • Pt 100 Ω P.70
Loop ohmmeters P.40 – 41, 45 RMS current recorder P.26
Loop testers P.29 – 32, 45 Rotation speed measurement
Luminance measurement P.76 P.52
Luxmeters P.76
Page T 104
INDEX BY PRODUCT
Portable, on-site and laboratory test and measurement instruments T 2009 catalogue Page T 105
10 SUBSIDIARIES WORLDWIDE
ITALY SWITZERLAND
AMRA SpA Chauvin Arnoux AG
Via S. Ambrogio, 23/25 Einsiedlerstrasse 535
20050 MACHERIO (MI) 8810 HORGEN
Tel.: +39 039 245 75 45 Tel.: +41 44 727 75 55
Fax: +39 039 481 561 Fax: +41 44 727 75 56
info@amra-chauvin-arnoux.it info@chauvin-arnoux.ch
www.chauvin-arnoux.it www.chauvin-arnoux.ch
906 131 088 - Ed.7 11/2008 - Non-contractual document. Specifications must be confirmes before ordering.
www.chauvin-arnoux.com
USA
Chauvin Arnoux Inc
d.b.a AEMC Instruments
200 Foxborough Blvd.
Foxborough - MA 02035
Tel.: (508) 698-2115
Fax: (508) 698-2118
sales@aemc.com
www.aemc.com
MANUMESURE
248 avenue des Grésillons
92601 Asnieres sur Seine
FRANCE
Tel.: +33 1 75 61 01 90
Fax: +33 1 47 33 28 02
info@manumesure.fr
www.manumesure.fr