0% found this document useful (0 votes)
20 views5 pages

6EP34347SB003AX0 Datasheet en

The document provides detailed specifications for the SITOP PSU6200/3AC/24VDC/10A power supply, which features a 3-phase AC input and delivers a stabilized 24 V DC output at 10 A. It includes information on input and output characteristics, efficiency, safety standards, and environmental conditions. Additionally, it outlines the product's certifications, dimensions, and connection methods.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
20 views5 pages

6EP34347SB003AX0 Datasheet en

The document provides detailed specifications for the SITOP PSU6200/3AC/24VDC/10A power supply, which features a 3-phase AC input and delivers a stabilized 24 V DC output at 10 A. It includes information on input and output characteristics, efficiency, safety standards, and environmental conditions. Additionally, it outlines the product's certifications, dimensions, and connection methods.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Data sheet 6EP3434-7SB00-3AX0

SITOP PSU6200/3AC/24VDC/10A

SITOP PSU6200 24 V/10 A stabilized power supply input: 400 - 500 V AC output:
24 V DC/10 A with diagnostics interface

input
type of the power supply network 3-phase AC or DC
supply voltage at AC
● minimum rated value 400 V
● maximum rated value 500 V
● initial value 323 V
● full-scale value 576 V
supply voltage at DC 500 ... 550 V
input voltage at DC 450 ... 600 V
buffering time for rated value of the output current in the event of 30 ms
power failure minimum
operating condition of the mains buffering at Vin = 400 V
line frequency 50/60 Hz
line frequency 47 ... 63 Hz
input current
● at rated input voltage 400 V 0.39 A
● at rated input voltage 500 V 0.32 A
current limitation of inrush current at 25 °C maximum 13 A
fuse protection type in the feeder three-poled coupled circuit breaker from 4 A characteristic C to 16 A
characteristic C or circuit breaker 3RV2011-1EA10 (setting 4 A) or 3RV2711-
1ED10 (UL 489)
output
voltage curve at output Controlled, isolated DC voltage
number of outputs 1
output voltage at DC rated value 24 V
output voltage
● at output 1 at DC rated value 24 V

output voltage adjustable Yes; via potentiometer


adjustable output voltage 24 ... 28 V; max. 240 W (288 W up to 45°C)
relative overall tolerance of the voltage 3%
relative control precision of the output voltage
● on slow fluctuation of input voltage 0.2 %
● on slow fluctuation of ohm loading 0.1 %
residual ripple
● maximum 30 mV
● typical 20 mV
voltage peak
● maximum 30 mV

6EP34347SB003AX0 Subject to change without notice


5/26/2025
Page 1/5 © Copyright Siemens
● typical 20 mV
display version for normal operation Green LED for 24 V OK
type of signal at output Electronic contact (NO contact, contact rating 30 V DC/0.1 A) for DC O.K. or
diagnostic interface
behavior of the output voltage when switching on Overshoot of Vout < 2 %
response delay maximum 0.5 s
voltage increase time of the output voltage
● typical 100 ms
output current
● rated value 10 A
● rated range 0 ... 10 A; 12 A up to +45°C; +60 ... +70 °C: Derating 3%/K

supplied active power typical 240 W


short-term overload current
● on short-circuiting during the start-up typical 12 A
● at short-circuit during operation typical 12 A
parallel switching of outputs can be set with DIP switch
bridging of equipment Yes; switchable characteristic
number of parallel-switched equipment resources for increasing 2
the power
efficiency
efficiency in percent 95.4 %
power loss [W]
● at rated output voltage for rated value of the output 12 W
current typical
● during no-load operation maximum 2.9 W
closed-loop control
relative control precision of the output voltage at load step of 2%
resistive load 10/90/10 % typical
setting time
● load step 10 to 90% typical 1 ms
● load step 90 to 10% typical 1 ms
● maximum 2 ms
protection and monitoring
design of the overvoltage protection < 32 V
property of the output short-circuit proof Yes
design of short-circuit protection Shutdown and periodic restart attempts
● typical 12 A
overcurrent overload capability
● in normal operation overload capability 150 % Iout rated up to 5 s/min
safety
galvanic isolation between input and output Yes
galvanic isolation ES1 output voltage Vout according to EN 62368-1
operating resource protection class Class I
leakage current
● maximum 3.5 mA
protection class IP IP20
EMC
standard
● for emitted interference EN 55022 Class B
● for mains harmonics limitation EN 61000-3-2
● for interference immunity EN 61000-6-2
standards, specifications, approvals
certificate of suitability
● CE marking Yes
● UL approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus
(CSA C22.2 No. 60950-1, UL 60950-1)
● CSA approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus
(CSA C22.2 No. 60950-1, UL 60950-1)
● UKCA marking Yes
● EAC approval Yes
● Regulatory Compliance Mark (RCM) Yes
● NEC Class 2 No

6EP34347SB003AX0 Subject to change without notice


5/26/2025
Page 2/5 © Copyright Siemens
● SEMI F47 Yes
type of certification
● BIS Yes; R-41188271
● CB-certificate Yes
standards, specifications, approvals hazardous environments
certificate of suitability
● IECEx No
● ATEX No
● ULhazloc approval No
● cCSAus, Class 1, Division 2 No
● FM registration No
standards, specifications, approvals marine classification
shipbuilding approval Yes
Marine classification association
● American Bureau of Shipping Europe Ltd. (ABS) Yes
● French marine classification society (BV) No
● Det Norske Veritas (DNV) Yes
● Lloyds Register of Shipping (LRS) No
standards, specifications, approvals Environmental Product Declaration
Environmental Product Declaration Yes
global warming potential [CO2 eq]
● total 393.2 kg
● during manufacturing 16.8 kg
● during operation 375.8 kg
● after end of life 0.42 kg
Siemens Eco Profile (SEP) Siemens EcoTech
ambient conditions
ambient temperature
● during operation -30 ... +70 °C; with natural convection a monotonically increasing start-up from
-25 °C, safe start-up from -40 °C
● during transport -40 ... +85 °C
● during storage -40 ... +85 °C
environmental category according to IEC 60721 Climate class 3K3, 5 ... 95% no condensation
connection method
type of electrical connection push-in terminals
● at input L1, L2, L3, PE: push-in for 0.5 ... 6 mm²
● at output +1, +2, -1, -2, -3: push-in for 0.5 ... 2.5 mm²
● for auxiliary contacts 13, 14 (alarm signal): 1 push-in terminal each for 0.2 ... 1.5 mm²
mechanical data
width × height × depth of the enclosure 45 × 135 × 155 mm
installation width × mounting height 45 mm × 225 mm
required spacing
● top 45 mm
● bottom 45 mm
● left 0 mm
● right 0 mm
fastening method Snaps onto DIN rail EN 60715 35x7.5/15
● DIN-rail mounting Yes
● S7 rail mounting No
● wall mounting No
housing can be lined up Yes
net weight 0.9 kg
accessories
electrical accessories Buffer module, redundancy module
mechanical accessories Identification labels SIMATIC ET 200SP 6ES7193-6LF30-0AW0
further information internet links
internet link
● to website: Industry Mall https://mall.industry.siemens.com
● to web page: selection aid TIA Selection Tool https://www.siemens.com/tstcloud
● to web page: power supplies https://siemens.com/sitop

6EP34347SB003AX0 Subject to change without notice


5/26/2025
Page 3/5 © Copyright Siemens
● to website: CAx-Download-Manager https://siemens.com/cax
● to website: Industry Online Support https://support.industry.siemens.com
identification link Yes; acc. to IEC 61406-1:2022
additional information
other information Specifications at rated input voltage and ambient temperature +25 °C (unless
otherwise specified)
security information
security information Siemens provides products and solutions with industrial cybersecurity functions
that support the secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber
threats, it is necessary to implement – and continuously maintain – a holistic,
state-of-the-art industrial cybersecurity concept. Siemens’ products and
solutions constitute one element of such a concept. Customers are responsible
for preventing unauthorized access to their plants, systems, machines and
networks. Such systems, machines and components should only be connected
to an enterprise network or the internet if and to the extent such a connection is
necessary and only when appropriate security measures (e.g. firewalls and/or
network segmentation) are in place. For additional information on industrial
cybersecurity measures that may be implemented, please visit
www.siemens.com/cybersecurity-industry. Siemens’ products and solutions
undergo continuous development to make them more secure. Siemens strongly
recommends that product updates are applied as soon as they are available
and that the latest product versions are used. Use of product versions that are
no longer supported, and failure to apply the latest updates may increase
customer’s exposure to cyber threats. To stay informed about product updates,
subscribe to the Siemens Industrial Cybersecurity RSS Feed under
https://www.siemens.com/cert. (V4.7)
Classifications
Version Classification

eClass 14 27-04-07-01
eClass 12 27-04-07-01
eClass 9.1 27-04-07-01
eClass 9 27-04-07-01
eClass 8 27-04-90-02
eClass 7.1 27-04-90-02
eClass 6 27-04-90-02
ETIM 9 EC002540
ETIM 8 EC002540
ETIM 7 EC002540
IDEA 4 4130
UNSPSC 15 39-12-10-04

Approvals Certificates
General Product Approval

Manufacturer Declara- Declaration of Con-


tion formity

General Product Approval Maritime application

Miscellaneous BIS CRS

Maritime application Environment

6EP34347SB003AX0 Subject to change without notice


5/26/2025
Page 4/5 © Copyright Siemens
last modified: 4/4/2025

6EP34347SB003AX0 Subject to change without notice


5/26/2025
Page 5/5 © Copyright Siemens