The document contains detailed structural drawings and specifications for a proposed locker room in Passi City, Philippines. It includes information on various materials, dimensions, and reinforcement details for beams, walls, and trusses. The drawings are prepared by a civil engineer and include approval and revision details.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views1 page

Locker Room Layout1

The document contains detailed structural drawings and specifications for a proposed locker room in Passi City, Philippines. It includes information on various materials, dimensions, and reinforcement details for beams, walls, and trusses. The drawings are prepared by a civil engineer and include approval and revision details.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

2-16mmØ RSB VERT.

A B C D E 4-16mmØ
VERT. BARS
BARS w/ 10mmØ RSB
16.00 TIES @ 0.20m. OC. 10mmØ RSB VERT. BARS @ REPUBLIC OF THE PHILIPPINES
w/ 10mmØRS LAT. TIES
sp. 3@ 0.05, 2@0.10 0.60m. & HOR. BARS @ EVERY
4.00 4.00 4.00 4.00
3.00 1.50 1.50 2.00 4.00 2.00 2.00
REST @ 0.20m OC
3-12mmØ
3-LAYERS OF CHB
4-12mmØ HOR. BARS
w/ 10mmØ TIES @ O.20m. OC. 0.15
D.P.W.H.
C1/F1 C1/F1 RSB MAIN BARS
C1/F1 C1/F1
w/ 10mmØ RSB TIES OFFICE OF THE BUILDING OFFICIALS

0.20
SC SC SC SC
4 WF WF WF
@ 0.60m. OC.
0.40

N.G.L
WF WF F.F.L

0.30
WF WF WF
3.78
3.78

3.78
WF WF SC WF
PASSI CITY

1.00

0.60
SC
SC SC SC
LINTEL BEAM DETAIL

1.25
C1/F1
SCALE 1:30MTS
WF WF WF 0.25
3

0.20
0.10
WF SC

0.25
1.69

1.69
C1/F1 C1/F1 C1/F1 C1/F1 C1/F1
WF WF 0.40
10mmØ RSB MATT BARS 4-16mmØ RSB HOR. BARS w/ 10mmØ RSB
WF
STIRRUPS SPACED @ 6@0.05m.,2@0.10m.,
11.45

@ 0.60m O.C B.W 1@ 0.15m. REST @ 0.20m. OC.


WF WF
SC DETAIL 0.20 0.20
1.27

1.27
WF 4"THK CHB WALL 6-16mmØ
SCALE 1:20MTS

0.30
WF DETAIL

0.30
SC SC
SCALE 1:30MTS

0.25

1.00
6-16mmØ 2-16mmØ STRUC TU RAL
WF
WF
WF 4-12mmØ RSB HOR. BARS w/ 10mmØ RSB
L/4 L/2 L/4 @ SUPPORT @ MIDSPAN
3.27

3.27
STIRRUPS SPACED @ 5-0.05m.,3-0.10m.,
REST @ 0.15m. OC.
0.15 L
C1/F1 C1/F1 C1/F1 C1/F1 C1/F1 3.78

0.20
WF 0.30 7-16mmØMATT.
WF WF WF
2 BARS BOTHWAYS
ROOF BEAM DETAIL
1.00
1.45

SCALE 1:30MTS
WF WF BEAM-1 DETAIL

2.40
WF WF WF
C1/F1 DETAIL SCALE 1:30MTS
A C D E
SCALE 1:30MTS
B
1 FOUNDATION PLAN WF WF
A C D E 16.00
SCALE 1:100MTS
B
16.00

A B C D E 4.00 4.00 4.00 4.00 INSIDE GUTTER


-SEE DTL.
3.00 1.50 1.50 2.00 4.00 2.00 2.00

0.60
16.00
4.00 4.00 4.00 4.00 4

0.60
3.00 1.50 1.50 2.00 4.00 2.00 2.00
4 RB RB RB RB

3.78
4 RB RB
RB RB
RB

3.78

3.78
RB RB
RB RB
3.78

3.78 3

RAFTER TRUSS-2

RAFTER TRUSS-2

RAFTER TRUSS-2
RAFTER TRUSS-2

T R U S S - 2

T R U S S - 2

T R U S S - 2
T R U S S - 2

T R U S S - 1
CB CB
3 RB RB RB RB

3.10
1.69

1.69
B1 RB
3

13.00
CB CB
11.45
1.69

1.69

13.00
1
4" THK ORD. PLYWOOD

1.27

1.27
PRATT TRUSS PRATT TRUSS PRATT TRUSS PRATT TRUSS
11.45

1.27

1.27

12.40

12mmX38mmX5m FURRING CHANNEL

3.13
SP. @ 0.60m O.C B.W RB
3.27

3.27
RB RB
SIDE GIRT-2 SIDE GIRT-2 SIDE GIRT-2 SIDE GIRT-2
19mmX50mmX5m CARRYING CHANNEL
2
3.27

3.27

SP. @ 1.20m O.C B.W


RB RB RB
2

TRUSS-3
2.40
RB
1.45

CB CB
2

2.40
B1 B1 RB RB SIDE GIRT-1
1
1.45

ROOF FRAMING PLAN


2.40

1
CEILING PLAN CB RB
SCALE 1:100MTS
SCALE 1:100MTS
1 ROOF BEAM FRAMING PLAN
SCALE 1:100MTS
19mmX50mmX5m
CARRYING CHANNEL
HANGER 19mmX50mmX5m
CARRYING CHANNEL 2-6mmX50mmX50mm ANGLE BAR FRAME
SP. @ 1.20m O.C B.W 2-6mmX38mmX38mm ANGLE BAR SUPPORT 2-6mmX50mmX50mm ANGLE BAR FRAME
W- CLIP 12mmX38mmX5m FURRING CHANNEL 2-6mmX38mmX38mm ANGLE BAR SUPPORT
3.00
SP. @ 0.60m O.C B.W 4-16mmØ RSB HOR. BARS w/ 10mmØ RSB 4.00
STIRRUPS SPACED @ 6@0.05m.,2@0.10m.,
A 1@ 0.15m. REST @ 0.20m. OC. 0.20

B
4-16mmØ
2-12mmØ
0.40
0.25

1.25
1.50
2-16mmØ

A-A

0.20
1 1.00 1.00 1.00 1.00
4" THK ORD. PLYWOOD 4-16mmØ
1.50 1.00 1.00 1.00
2-12mmØ
0.25

25mmX25mm WALL ANGLE 2-16mmØ


CANTILIVER BEAM DTL. B-B
CEILING DETAIL scale 1:30 mts.
SECTION
SIDE GIRT-1 DTL. SIDE GIRT-2 DTL.
scale 1:40 mts. scale 1:40 mts.
SCALE 1:10mts.

ARCHITECH/CIVIL ENGINEER PRC NO.: 0162295 PROJECT TITLE / LOCATION : APPROVED BY: SHEETCONTENT REVISION SHEET NO.
DRAWNED BY:
TIN: 736-820-178
PREPARED BY:
PTR NO.: 7761313
ANTONIO STEVEN L. CHAN S
EL FRED A. DEL CASTILLO DATE of ISSUE: 1-7-2020
PROPOSED LOCKER ROOM DATE:
CIVIL ENGINEER
CENTRAL AZUCARERA DE SAN ANTONIO INC. S 3
PLACE of ISSUE: PASSI CITY LOCATION : BRGY. CADILANG, PASSI CITY OWNER PLACE: