Incorporating
FAS 10 mm PICOSOL
Direct acting solenoid valve
> 2/2, 3/2;
Manifold mounting
> Compact Design
> Long life – 100 million
cycles
> Low power
consumption
Technical features
Medium: Flow: Life expectancy: Materials:
Air, oxygen, neutral gases 5 … 32 l/min at 2 bar (29 psi) ≥100 Mio. cycles for 1 W valves Body: PPS
(10% ... 95% humidity, non at +20°C (+68°F) Weight: Seat seals: FPM, NBR, EPDM
condensing), 40 μm filtered Mounting: 10,5 g (0,023 lbs) Internal parts:
Operation: Manifold Ambient/media temperature: Stainless steel, PAA
Direct acting 2-way and 3-way Orifice: –10 ... +50°C (+14 ... +122°F)
valves, normally closed and 0,6 … 2 mm Air supply must be dry enough
normally opened Response time: to avoid ice formation at
Operating pressure: 10 ... 15 ms temperatures below +2°C (+35°F).
0 ... 10 bar (0 ... 145 psi) Response time measured
Details on page 2 according to ISO 12238
Electrical details Following options Embedded
Voltage 24 V d.c.
on request electronics options
Rating 100% E.D. Operating pressure (vacuum) Integrated pulse width modulation (PWM)
Voltage tolerance ± 10% Medium temperature Enhanced opening time repeatability
Power consumption 1[W] (3/0,3 W)* Ambient temperature Larger input voltage tolerances
Electrical insulation 1000 V a.c. Response time Improved boosting by plunger movement
Protection class IP51 Power consumption detection
Insulation class F (155°C) Materials Improved boosting by plunger movement
detection with power adaptation
* with optional PWM control Coils
Faster valve closing
Protection class
Current control for improved
Degreased for oxygen use performances over temperature range
Manual override Reverse polarity protection
Pulse width modulation (PWM) control Led signalization
A PWM can be used to control the valve and should be set as follows:
Definition Value to be applied
Hit voltage Voltage used for the valve to commute Valve nominal voltage
Holding voltage Voltage applied to the valve after commutation Set duty cycle to guarantee specified holding voltage.
50% of nominal voltage can be used if no value specified.
Hit time Maximum time required to ensure full valve commutation 40 ms at T > 20°C *1)
PWM frequency 20 ... 30 kHz
*1) Please contact us for application outside of those conditions.
Our policy is one of continued research and development. We therefore reserve the right to amend, 09/20
without notice, the specifications given in this document. (2006 - 5017e) © 2020 Fluid Automation Systems s.a. en 5.2.030.01
Incorporating
Technical data – standard models
Symbol Operation Orifice Operating kv*2) Power Voltage Manual Seal Drawing Model
3 10 12 3 10 pressure consumption override material
*3) *4)
2 2 (mm) (bar) (psi) (l/min) (W) (V d.c.) No.
32 10
10 12
12 32 10
10 0,6 0 ... 10 0 ... 145 0,12 1 24 With FPM 2 11-221PI060H1+1111+AYV
2/2 NO
(3/2 mounting 1,1 0 ... 4 0 ... 58 0,3 1 24 With FPM 2 11-221PI011H1+1111+AYR
21 21 pattern)
32 10
10 12 32 10
10 0,6 0 ... 8 0 ... 116 0,12 1 24 With FPM 2 11-211PI060H1+1111+AYV
12 2/2 NC
(3/2 mounting 0,8 2 ... 8 29 ... 116 0,19 1 24 With FPM 2 11-211PI01-H1+1111+AYV
pattern) 1,1 0,5 ... 2,1 7,2 ... 30 0,3 1 24 With FPM 2 11-211PI011H1+1111+AYV
21 21
22210 0,8 0 ... 8 0 ... 116 0,2 1 24 Without FPM 1 11-211P601-H1+1311+AYV
2 1010 12
12
12 222 10
10
2/2 NC 1,2 0 ... 4 0 ... 58 0,39 1 24 Without FPM 1 11-211P602-H1+1311+AYR
111 3 111 3 1,6 0 ... 8 0 ... 116 0,54 4/0,4 24 Without FPM 1 11-211P603-H1+6311+AXA
2 10 2 10
0,6 0 ... 8 0 ... 116 0,12 1 24 With FPM 2 11-311PI060H1+1111+AYV
2 10 12 2 10
2 12
2 2 10 12 2 10 0,8 2 ... 8 29 ... 116 0,19 1 24 With FPM 2 11-311PI01-H1+1111+AYV
3/2 NC
1 1 1,1 2 ... 8 29 ... 116 0,37 3/0,3 24 With FPM 2 11-311PI011H1+6111+AZR
1 3 1 3
1 3 1 3
1,3 2 ... 6,5 29 ... 94 0,44 3/0,3 24 With FPM 2 11-311PI013H1+6111+AZR
2 210 12 22 10
2
2 2 10 12 2 10 0,8 0 ... 6 0 ... 87 0,19 1 24 With FPM 2 11-321PI01-H1+1111+AYV
2 2 1010
12
12 2 10
10
11 1 3/2 NO
1 3
3 1
1 33
1 3 1 3
2 2
2 10 12 2
2 10 0,8 0 ... 2 0 ... 29 0,18 1 24 With FPM 2 11-331PI01-H1+1111+AYV
2 10 12 10
3/2 UNI
1
1 3
3 1
1 3
3
2
*2) Cv =120,07 kv2 10
2 10
*3) Power consumption: “boosting power during ca. 50 ms”/ “holding power”
*4) Push only
1 3 1 3
Accessories Electrical connection
Mounting plate with barbed Mounting manifold with M3 threads — Mounting manifold with M5 threads — Electrical connector Molex 50-57-
fittings for 3 mm ØID tubing 1 position 1 ... 8 positions 9402 with 300 mm flying leads
(up to 2 bar)
Page 4 Page 4 Page 5 Page 5
S111.1772 S110.1277 Available on request S110.1032
Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.2.030.02 without notice, the specifications given in this document. (2006 - 5017e) © 2020 Fluid Automation Systems s.a. 09/20
Incorporating
Dimensions Dimensions in mm
Projection/First angle
1
6,4
2,54 2
18,5
32
23
A
7
3
12,4 6,2
4
2,6
A
10
3,5 22,7 1
1,9
M2
3,9
8,5
2
4,5
2
2
6,4
2,54 2
18,5
32
23
A
6,2
3
12,4 6,8
4
A
10
M1,6
0,2
3,5 22,7
3
2,7 2,7
2
1
1,6
0,8
2,4
2 4
1 Manual override, push only
2 Sealing area
3 he recommended
T
mounting screw tightening torque
is 0,15 Nm.
4 onnector mates with
C
Molex 50-57-9402
All solenoids are supplied with
mounting screws and gasket.
Our policy is one of continued research and development. We therefore reserve the right to amend,
09/20 without notice, the specifications given in this document. (2006 - 5017e) © 2020 Fluid Automation Systems s.a. en 5.2.030.03
Incorporating
Mounting plate with barbed fittings for Mounting manifold Dimensions in mm
Projection/First angle
3 mm ØID tubing (up to 2 bar) Model: S110.1277
Model: S111.1772
14,5 1
A
6,5 2
3
15
10,5
2
2,6
2 9
7
R
3 1
6,5
M5 10,5 5
3
5,5 7,5 19,5
5,5
10
A
M5
20
12
5,5
5 M5
ø1,8
ø3,6
13
1 Mounting thread M2 x 5 deep
Mounting manifold
Model: on request
M5 M5
20
14
4,5
5 6 10,5 ±0,1
8 (N-1) x 10,5
5
3
15
3
X
Y
M5
10,5
6 10,5 ±0,1
(N-1) x 10,5 5 Mounting thread M3 x 4,5 deep
Valve station X Y
2 16,5 22,5
3 27 33
4 37,5 43,5
5 48 54
6 58,5 64,5
7 69 75
8 79,5 85,5
Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.2.030.04 without notice, the specifications given in this document. (2006 - 5017e) © 2020 Fluid Automation Systems s.a. 09/20
Incorporating
Electrical connector Dimensions in mm
Projection/First angle
Model: S110.1032
5,5
2,54 15
Texte sind in Datei „#Texte Standardzusätze.xslx“ erfasst!
Bescheibung in „#Anleitung DGRL-Hinweise.pdf“
Rahmenhöhe belassen.
Keine Rahmen löschen – Absatzformate sind sprachabhängig (Silbentrennung)!
Am Ende des Absatzes in der Spalte einen Spaltenumbruch einfügen (Enter-Taste - nicht Return)
EN - Englisch Warning_FAS_air_oxygen_neutral_gases
Warning
These products are intended for use in air, oxygen and neutral gas The system designer is warned to consider the failure modes
systems only. Do not use these products where pressures and of all component parts used in fluid power systems and to provide
temperatures can exceed those listed under »Technical features«. adequate safeguards to prevent personal injury or damage
to equipment in the event of such failure.
Before using these products with fluids other than those specified,
for non-industrial applications, life-support systems, or other System designers must provide a warning to end users in the system
applications not within published specifications, consult instructional manual if protection against a failure mode cannot be
IMI Precision Engineering, Fluid Automation Systems s.a. adequately provided.
Through misuse, age, or malfunction, components used in fluid
power systems can fail in various modes.
Our policy is one of continued research and development. We therefore reserve the right to amend,
09/20 without notice, the specifications given in this document. (2006 - 5017e) © 2020 Fluid Automation Systems s.a. en 5.2.030.05