0% found this document useful (0 votes)
26 views1 page

Electrical Revised Model

The document provides detailed electrical layouts for various floors, including ground, second, third, and roof deck lighting. It includes specifications for different types of LED lights, switches, and wiring methods, as well as compliance notes with the Philippine Electrical Code. Additionally, it outlines installation guidelines and mounting heights for electrical devices.

Uploaded by

alemarforex01
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
26 views1 page

Electrical Revised Model

The document provides detailed electrical layouts for various floors, including ground, second, third, and roof deck lighting. It includes specifications for different types of LED lights, switches, and wiring methods, as well as compliance notes with the Philippine Electrical Code. Additionally, it outlines installation guidelines and mounting heights for electrical devices.

Uploaded by

alemarforex01
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

LEGEND:

SYMBOL DESCRIPTION

1 2 3 4 1 2 3 4 - 3W, 230V, LED PIN LIGHT, SLIM TYPE, DL

- 6W, 230V, LED PIN LIGHT, SLIM TYPE, DL


3000 4000 3000
4000 2000
- 12W, 230V, LED PIN LIGHT, SLIM TYPE, DL
- 3X5W, 230V, LED DROP LIGHT SLIM
W W
2 1
D D - 6W, LED LIGHT WITH HOUSING, SURFACE TYPE

g
h h S/Sa - ONE GANG DEVICE SWITCH
2000
Sab
s s

W W 3000 - TWO GANG DEVICE SWITCH


Sg 1 1
C Sef Sh
C Scde - THREE GANG DEVICE SWITCH
D q
3 d d
t

Stu
Ss
Sqr
S3W - THREE WAY DEVICE SWITCH
- RACEWAY CONDUIT CONCEALED IN CEILING
3000
4000 e c
t
u
o - RACEWAY CONDUIT CONCEALED UNDER FLOOR
q
W f 1
2 DPB r
2
2
DPB - PANEL BOARD, MARKED AS "LP"
d
DPA
d
Sno
DPA
f
f Scd v
- CKT. BREAKER, RATING AS INDICATED
B B n n
p 2000
- DUPLEX CONVENIENCE OUTLET, GROUNDING
3000 Sv

DPB
b b
Sp TYPE, 20A, 250V "WP"DENOTES, WEATHER
1 W
DPA 3 v Sm PROOF OUTLET
m

W Sab
ACU - AIR CON DITIONING UNIT
4000 1
a

UP j j
w
to S3W i
up
W
3
k k to S3W x
up m - SERVICE METER
b b
3000
Sv Sjkl
A A S3W i - SERVICE ENTRANCE
w

l l
2000

ELECTRICAL NOTES:
W
1
i i

W W
4 4

1. ALL ELECTRICAL WORKS SHALL COMPLY IN ACCORDANCE


WITH THESE PLANS & SPECIFICATIONS. THE APPLICABLE
1 GROUND FLOOR LIGHTING LAYOUT 2 SECOND FLOOR LIGHTING LAYOUT PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE
ELECTRICAL CODE (PEC ). THE RULES & REGULATION OF
THE LOCAL ENFORCING AUTHORITY & THE REQUIREMENTS
OF THE LOCAL POWER COMPANY. THE ELECTRICAL WORKS
SHALL BE UNDER IMMEDIATE SUPERVISION OF A DULY
REGISTERED ELECTRICAL ENGINEER.
1 2 3 4 1 2 3 4
2. THE ELECTRICAL SERVICE POWER IS 1-PHASE, 2-WIRE 230 V
AC, 60 Hz.
3000 4000 3000
3. WIRING METHOD SHALL BE AS FOLLOWS;
5000
A. FEEDERS & RISERS - INTERMEDIATE METALLIC CONDUIT
D 10000 B. LIGHTING, POWER RECEPTACLE - POLYVINYL CHLORIDE
3000
CONDUIT
2000 TERRACE
W
5
W
5
4. ALL WIRES SHALL BE COPPER & THERMOPLASTIC
C S3W h' C DOWN TO INSULATED TYPE "THW" UNLESS OTHERWISE INDICATED IN
c' AT 3RD FLOOR
UP
1
DPC THE PLAN. THE MINIMUM SIZE OF WIRE FOR POWER AND
a' b'
LIGHTING CIRCUIT HOMERUN SHALL BE 3.5mm &
i'

4000
d' d' d' Si' INSULATED FOR 600 VOLTS. SMALLEST RACEWAY SHALL BE
c' DOWN
a' b'
S3W h'
down
W
6
Sc'd' i'
5. ALL OUTLET BOXES SHALL BE GALVANIZED GAGE NO. 16
5400
B g' Sa'b'
B Sj'
ROOF DECK DEEP TYPE FOR THE PARTICULAR LOCATION & PURPOSE OF
1 Sy
W
6
DPC
USAGE.
Sg'
z
DPC

Se'f' j'
f' 6. ALL MATERIALS TO BE USED SHALL BE BRAND NEW &
f'
APPROVED TYPE FOR THE PARTICULAR LOCATION &
e' z y
5000
PURPOSE OF USAGE.
f' f'
Sz
CLOSET
S3W x
7. GROUNDING SYSTEM SHALL BE PROVIDED TO ALL LIGHTING
A W
DOWN A & POWER CIRCUIT AS PER PHILIPPINE ELECTRICAL CODE
1
REQUIREMENT.
x x
8. MOUNTING HEIGHT OF WIRING DEVICES SHALL BE AS
W
4 FOLLOWS :
A.LIGHT SWITCH - 1.20 M ABOVE FINISH FLOOR
B.CONVENIENCE OUTLET - 0.30 M ABOVE FINISH FLOOR
3 THIRD FLOOR LIGHTING LAYOUT 4 ROOF DECK LIGHTING LAYOUT C.PANELBOARD - 1.50 M ABOVE FINISH FLOOR

You might also like