0% found this document useful (0 votes)
15 views4 pages

iHFG Standard Components: International Health Facility Guidelines

The document outlines the layout and components for a cardiac operating room, including various medical equipment and furniture such as anaesthetic machines, monitors, and power outlets. It specifies the room codes and includes details on the placement of each component within the room. Additionally, it notes the requirements for radiation shielding and service adjustments based on project needs.

Uploaded by

Mohamed Amr
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
15 views4 pages

iHFG Standard Components: International Health Facility Guidelines

The document outlines the layout and components for a cardiac operating room, including various medical equipment and furniture such as anaesthetic machines, monitors, and power outlets. It specifies the room codes and includes details on the placement of each component within the room. Additionally, it notes the requirements for radiation shielding and service adjustments based on project needs.

Uploaded by

Mohamed Amr
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

iHFG Standard Components

Room Layout Sheet

RLS Room Code or-ca-i


Room Name Operating Room - Cardiac RDS Room Code or-ca-i

ANMM ANAESTHETIC - MACHINE WITH ANAESTHETIC MONITOR PO/C POWER OUTLET - CLEANER'S
AV AUDIO VISUAL OUTLET PTZ PAN-TILT-ZOOM CAMERA
SERVCIE 4 x AV
AV/DC AUDIO VISUAL OUTLET - DIRECT CONNECTION PU/IN1 PUMP - INFUSION, SINGLE PENDANT - 4 x COM/2
BNR BENCH - RESINATE PU/IR PUMP - INFUSION, RAPID SURGICAL DROP 1 x O2
BRCCM BRACKET - CARDIAC MONITOR PU/S PUMP - SYRINGE (SPE/S) 1 x MA
BS1 BOWL STAND - SINGLE PU/SAM PUMP - SUCTION, ASPIRATOR, MOBILE 1x S
CARP CARDIAC PROTECTED PU/SAP PUMP - SUCTION, ASPIRATOR, PORTABLE 2 x SA (FOR DRILLS)
CBT/BFW CABINET - BLANKET/ FLUID WARMING RAG RETURN AIR GRILLE 1 x CO2 (OPTIONAL)
10 x PO/1I
CBT/SER CABINET - SERVER, OPERATING THEATRE INTEGRATION S SUCTION
1 x DCE
CBT/STO CABINET - STORAGE, OPERATING THEATRE INSTRUMENT SA SURGICAL AIR 1 x TA/DC (FOR SUPPLY UNIT BRAKES)
CHR/A CHAIR - ANAESTHETIST SAC STAFF ASSIST CALL
CMP COMPUTER SB SUCTION BOTTLE
L/O2M 1 x AV (MON/D)
COM/1 COMMUNICATION OUTLET - SINGLE SBC SUCTION BOTTLE CARRIER
(IN CEILING 1 x COM/2 (MON/D)
COM/2 COMMUNICATION OUTLET - DOUBLE SC SCAVENGE OUTLET OUTLETS) 1 x DCU/1
COM/DC COMMUNICATION OUTLET - DIRECT CONNECTION SK4 FLOOR VINYL COVED SKIRTING 1 x PO/2U (MON/D)
CONP/SR CONTROL PANEL - SURGICAL, RECESSED SME SMOKE EVACUATOR
DCE DIRECT CONNECTION - EMERGENCY POWER SUPPLY SPE/A SERVICES PENDANT - ANAESTHESIA L/O3CM2 2 x AV (MON/D & MON/TS)
DCU/1 DIRECT CONNECTION - UNINTERRUPTED POWER SUPPLY, SINGLE SPE/P SERVICES PENDANT - PERFUSSIONIST (IN CEILING 2 x COM/2 (MON/D & MON/TS)
DDG DISPENSER - DISPOSABLE GLOVES SPE/S SERVICES PENDANT - SURGICAL OUTLETS) 1 x DCU/1
DFP DOOR AND DOOR FRAME PROTECTION ST/O STOOL - OPERATING, MOBILE 2 x PO/2U (MON/D & MON/TS)
1 x COM/DC (IN LIGHT CAMERA)
DFR DEFIBRILLATOR T/A TROLLEY - ANAESTHETIC
EC EMERGENCY CALL T/AMD TROLLEY - AUTOMATED MEDICATION DISPENSING
ESU ELECTRO SURGICAL UNIT T/G TROLLEY - GOWNS CONP/SR 1 x DCU/1
1 x COM/DC
HHU HYPO-HYPERTHERMIA UNIT T/I TROLLEY - INSTRUMENT
IM/USU IMAGING - ULTRASOUND SCANNING UNIT T/R TROLLEY - RESUSCITATION, ADULT
IVS IV STAND - MOBILE TA/DC TOOL AIR - DIRECT CONNECTION MON/D 55" 2 x AV (1 PER MONITOR)
KB KICKBUCKET & STAND TB/MY TABLE - MAYO (BOTH) 2 x COM/2 (1 PER MONITOR)
2 x PO/2U (1 PER MONITOR)
L/CCD LIGHT - COLOUR CORRECTED, DIMMABLE TP/HH TELEPHONE - HANDSET, HANDSFREE
L/LA LIGHT - 'LASER IN USE' V1 VINYL FLOORING, STANDARD SLIP RESISTANT
MON/TS 1 x AV
L/O2M LIGHT - OPERATING, 2-ARM, 1 LIGHT / 1 MONITOR WPFSR WALL PAINT FINISH, SCRUB RESISTANT
(WALL MOUNTED 1 x COM/2
L/O3CM2 LIGHT - OPERATING, 3-ARM, 1 LIGHT WITH CAMERA / 2 MONITORS WV WALL VINYL FULLY RECESSED) 1 x PO/2U
LIND/S LINEN CARRIER - DIRTY, SINGLE
MA MEDICAL AIR
SERVICE 4 x AV (2 PER ARM) PTZ, OPTIONAL 1 x COM/DC
MON/C MONITOR - CARDIAC (IN CEILING 1 x DCU/1
PENDANT - 4 x COM/2 (2 PER ARM)
MON/D MONITOR - DISPLAY ANAESTHETIC 1 x O2 (ANAESTHESIA ARM) OUTLETS)
MON/TS MONITOR - TOUCH SCREEN DROP (SPE/A) 2 x O2 (PERFUSIONIST ARM)
N2O NITROUS OXIDE PERFUSSIONIST 2 x N2O (ANAESTHESIA ARM) NOTE:
DROP (SPE/P) 1 x MA (ANAESTHESIA ARM) RADIATION SHIELDING REQUIREMENTS TO BE PROVIDED BY A QUALIFIED
O2 OXYGEN
2 x MA (PERFUSIONIST ARM) RADIATION SHIELDING CONSULTANT
OPC ORDERLY/ PORTER CALL
OPS/R OBSERVATION PANEL WITH SLIDING PANEL - RADIATION SHIELDING 1 x S (ANAESTHESIA ARM) NOTE:
2 x S (PERFUSIONIST ARM) NUMBER OF REQUIRED SERVICES PER PENDANT TO BE ADJUSTED TO MEET
OPV OBSERVATION PANEL WITH INTEGRAL VENETIAN BLINDS
2 x SC (ANAESTHESIA ARM) PROJECT REQURIEMENTS BUT NOT TO BE LESS THAN THE NUMBERS SHOWN
OTA/M OPERATING TABLE - MOBILE, ELECTRIC 1 x CO2 (PERFUSIONIST ARM) - (OPTIONAL) HERE.
PC2 PLASTERBOARD CORNICE, FLUSHED COVED 1 x EC
PO/1-32A POWER OUTLET - SINGLE, 32 AMPS 1 x SAC NOTE:
PO/1I ISOLATED POWER SUPPLY - SINGLE 1 x OPC (OPTIONAL) WALL FINISH: FULL HEIGHT WALL VINYL OR EPOXY PAINT OR WPFSR.
20 x PO/1I (10 PER ARM) DOOR: LAMINATED DOOR PANEL WITH ENAMEL PAINT FINISH ON METAL DOOR
PO/2E POWER OUTLET - EMERGENCY, DOUBLE
1 x DCE FRAME
PO/2U UNINTERRUPTED POWER SUPPLY - DOUBLE
8400 1 x TA/DC (FOR SUPPLY UNIT BRAKES)

725 CL OF WALL 7675 WALL CL 725


SERVICES CL OF ROOM FROM STERILE STOCK/SETUP (SLIDING DOOR OPTIONAL)
ZONE L/LA
CL OF WALL
920MM CLEAR

LOW LEVEL RAG


LOW LEVEL RAG

T/R
PU/SAP

T/G OPENING
BS1
CHR/A
DFR

T/A
900

TB/MY
IVS IVS T/AMD
PU/S PU/S PU/IR IM/USU BS1
PU/IN1 PU/IN1 CARDIAC/ECHO (OPTIONAL)

KB SERVICES
ZONE
SPE/P
900

CBT/STO MON/D
(OPTIONAL) MON/C KB
SPE/A (FULLY
BRCCM HEAT LUNG RECESSED,
BYPASS OPTIONAL)
MACHINE LIND/S
725 HEPA FILTER
T/I
IN CEILING
ANMM
1850

LIND/S
MON/D T/I
(FULLY
RECESSED, MON/TS
OPTIONAL) (FULLY
T/I RECESSED,
6850

CL OF ROOM OPTIONAL)
PUMP -
L/O2M L/O3CM2 INTRA-AORTIC
(OPTIONAL)

CBT/BFW BALLOON CMP BNR


(OPTIONAL) (OPTIONAL)
MON/D

(OPTIONAL)
MON/TS MON/D

ST/O

AUTOMATED OTA/M
SUPPLY TP/HH
2200

STATION - ST/O
ESU , SME
MAIN UNIT MOUNTED ON
SUP/S SPE/S
COAGULATION
AUTOMATED UNIT - ACT

SERVICES
SUPPLY
STATION -
1550
55 m² CBT/SER
(OPTIONAL)
AUX UNIT 1 CARP FLOOR=V1
ZONE 4 2
3
LOW LEVEL RAG

LOW LEVEL RAG

SB SB
SBC
SB SB
1600MM CLEAR PU/SAM
HHU 1600MM CLEAR
OPENING OPENING
CL OF WALL
L/LA CONP/SR DDG L/LA SERVICES
FROM ANESTHETIC INDUCTION ROOM EXIT BAY & (SLIDING DOOR ZONE
CL OF COLUMN (SLIDING DOOR OPTIONAL) SCRUB UP OPTIONAL) CL OF COLUMN

PLAN
REV DESCRIPTION DATE BY REV DESCRIPTION DATE BY COMPATIBILITY
1 FIRST ISSUE 27.01.23 AK
iHFG

International Health Facility Guidelines at: DESIGNED APPROVED SCALE(S) SHEET


International Health
DATE
www.healthdesign.com.au/ihfg
Editable version of Standard Components on
AK RH 27.01.23 1 : 50 1 OF 4

Facility Guidelines
Health Facility Briefing System (HFBS) at: REVIT FILE NAME PAPER DRAWING ID ISSUE
www.healthdesign.com.au ©TAHPI
or-ca-i or-ca-i-1 1
This document is for advisory purpose only
iHFG Standard Components
Room Layout Sheet

RLS Room Code or-ca-i


Room Name Operating Room - Cardiac RDS Room Code or-ca-i

BNR BENCH - RESINATE


PTZ
BS1 BOWL STAND - SINGLE 3000
CBT/BFW CABINET - BLANKET/ FLUID WARMING PC2 WPFSR PC2
CBT/SER CABINET - SERVER, OPERATING THEATRE INTEGRATION
CBT/STO CABINET - STORAGE, OPERATING THEATRE INSTRUMENT
CHR/A CHAIR - ANAESTHETIST
2200
CMP COMPUTER
COM/1 COMMUNICATION OUTLET - SINGLE CBT/STO IVS IVS
(OPTIONAL)
COM/2 COMMUNICATION OUTLET - DOUBLE

PU/IN1

PU/IN1
CONP/SR CONTROL PANEL - SURGICAL, RECESSED IM/USU
CARDIAC/ECHO

PU/SAP
DDG DISPENSER - DISPOSABLE GLOVES (OPTIONAL)

OPS/R
DFP DOOR AND DOOR FRAME PROTECTION T/AMD

PU/IR
DFR DEFIBRILLATOR

PU/S

PU/S
HHU HYPO-HYPERTHERMIA UNIT T/G DFR BS1
900

TB/MY

CHR/A
IM/USU IMAGING - ULTRASOUND SCANNING UNIT DFP
T/A T/R
IVS IV STAND - MOBILE 600
KB KICKBUCKET & STAND
L/O2M LIGHT - OPERATING, 2-ARM, 1 LIGHT / 1 MONITOR 300 DOOR FROM
L/O3CM2 LIGHT - OPERATING, 3-ARM, 1 LIGHT WITH CAMERA / 2 MONITORS 150 STERILE SK4
SK4 STOCK
LIND/S LINEN CARRIER - DIRTY, SINGLE 0 SK4
MON/D MONITOR - DISPLAY PO/2E PO/2U PO/2E

ELEVATION 1
COM/1
MON/TS MONITOR - TOUCH SCREEN
OPS/R OBSERVATION PANEL WITH SLIDING PANEL - RADIATION SHIELDING
3000
OPV OBSERVATION PANEL WITH INTEGRAL VENETIAN BLINDS
PC2 WPFSR L/O3CM2 WPFSR PC2
PC2 PLASTERBOARD CORNICE, FLUSHED COVED
PO/1-32A POWER OUTLET - SINGLE, 32 AMPS
PO/2E POWER OUTLET - EMERGENCY, DOUBLE
PO/2U UNINTERRUPTED POWER SUPPLY - DOUBLE 2200
PO/C POWER OUTLET - CLEANER'S MON/D MON/TS WPFSR
MON/D (OPTIONAL) (OPTIONAL)
PTZ PAN-TILT-ZOOM CAMERA WV
(FULLY
PU/IN1 PUMP - INFUSION, SINGLE RECESSED, CBT/SER
PU/IR PUMP - INFUSION, RAPID OPTIONAL) (OPTIONAL)
MON/TS COAGULATION
PU/S PUMP - SYRINGE (OPTIONAL) CMP UNIT, ACT
PU/SAM PUMP - SUCTION, ASPIRATOR, MOBILE (FULLY RECESSED)
PU/SAP PUMP - SUCTION, ASPIRATOR, PORTABLE 1100

(OPTIONAL)
TP/HH

PO/1-32A
RAG RETURN AIR GRILLE 900

SBC
BS1 BS1 LIND/S LIND/S BNR

PO/2U
COM/2

SB

SB
SB SUCTION BOTTLE

PO/2U
PO/2U
COM/2
COM/2
COM/1
WPFSR
SBC SUCTION BOTTLE CARRIER 600 WV
KB KB

RAG
RAG

SK4 FLOOR VINYL COVED SKIRTING


300
SPE/S SERVICES PENDANT - SURGICAL
150 SK4 SK4
T/A TROLLEY - ANAESTHETIC SK4
0 SK4 SK4
T/AMD TROLLEY - AUTOMATED MEDICATION DISPENSING
2 x PO/2U (OPTIONAL)
T/G TROLLEY - GOWNS PUMP - INTRA-AORTIC BALLOON
T/I
T/R
TROLLEY - INSTRUMENT
TROLLEY - RESUSCITATION, ADULT
ELEVATION 2
TB/MY TABLE - MAYO 3000
TP/HH TELEPHONE - HANDSET, HANDSFREE PC2 WPFSR WPFSR PC2
WPFSR WALL PAINT FINISH, SCRUB RESISTANT SPE/S
WV WALL VINYL ENAMEL PAINT FINISH ON
METAL DOOR FRAME
2200 LAMINATED DOOR PANEL
SERVICE 4 x AV (2 PER ARM)
PENDANT - 4 x COM/2 (2 PER ARM) CBT/SER CONP/SR
ANAESTHETIC 1 x O2 (ANAESTHESIA ARM) (OPTIONAL)
DROP (SPE/A) 2 x O2 (PERFUSIONIST ARM)
DDG
PERFUSSIONIST 2 x N2O (ANAESTHESIA ARM)
DROP (SPE/P) 1 x MA (ANAESTHESIA ARM)
OPV

OPV
2 x MA (PERFUSIONIST ARM) 1200 CMP
1 x S (ANAESTHESIA ARM)
2 x S (PERFUSIONIST ARM)
SBC

900 BNR HHU PU/SAM


SB

SB

PO/C

2 x SC (ANAESTHESIA ARM) DFP DFP DFP DFP


1 x CO2 (PERFUSIONIST ARM) (OPTIONAL) 600
1 x EC
PO/2E

1 x SAC 300 EXIT DOOR ANAESTHETIC


1 x OPC (OPTIONAL) 150 TO BAY INDUCTION ROOM
20 x PO/1I (10 PER ARM) SK4 SCRUB SK4 SK4 (OPTIONAL) SK4
0 SK4
1 x DCE

ELEVATION 3
1 x TA/DC (FOR SUPPLY UNIT BRAKES)

SERVCIE 4 x AV (OPTIONAL) PTZ


PENDANT - 4 x COM/2 3000
SURGICAL DROP 1 x O2 PC2 WPFSR WPFSR PC2
L/O2M
(SPE/S) 1 x MA
1x S AUTOMATED AUTOMATED
2 x SA (FOR DRILLS) SUPPLY SUPPLY
10 x PO/1I 2200 STATION - STATION -
1 x DCE AUX UNIT MAIN UNIT MON/D
1 x TA/DC (FOR SUPPLY UNIT BRAKES) (OPTIONAL)
MON/D CBT/STO
(FULLY (OPTIONAL)
L/O2M 1 x AV (MON/D) RECESSED,
(IN CEILING 1 x COM/2 (MON/D) CBT/BFW
(OPTIONAL) OPTIONAL)
OUTLETS) 1 x DCU/1
1 x PO/2U (MON/D)
T/I T/I T/I TB/MY
L/O3CM2 2 x AV (MON/D & MON/TS)
(IN CEILING 2 x COM/2 (MON/D & MON/TS) RAG RAG
OUTLETS) 1 x DCU/1 600
PO/2E
PO/2U
COM/2

2 x PO/2U (MON/D & MON/TS)


300
PO/2U
COM/2

1 x COM/DC (IN LIGHT CAMERA)


150 SK4
0 SK4 SK4
CONP/SR 1 x DCU/1
1 x COM/DC SK4
ELEVATION 4 NOTE:
RADIATION SHIELDING REQUIREMENTS TO BE PROVIDED BY A QUALIFIED
MON/D 55" 2 x AV (1 PER MONITOR) RADIATION SHIELDING CONSULTANT
(BOTH) 2 x COM/2 (1 PER MONITOR)
NOTE:
2 x PO/2U (1 PER MONITOR)
NUMBER OF REQUIRED SERVICES PER PENDANT TO BE ADJUSTED TO MEET
MON/TS 1 x AV PROJECT REQURIEMENTS BUT NOT TO BE LESS THAN THE NUMBERS SHOWN
(WALL MOUNTED 1 x COM/2 HERE.
FULLY RECESSED) 1 x PO/2U
NOTE:
WALL FINISH: FULL HEIGHT WALL VINYL OR EPOXY PAINT OR WPFSR.
PTZ, OPTIONAL (IN 1 x COM/DC
DOOR: LAMINATED DOOR PANEL WITH ENAMEL PAINT FINISH ON METAL DOOR
CEILING OUTLETS) 1 x DCU/1
FRAME

REV DESCRIPTION DATE BY REV DESCRIPTION DATE BY COMPATIBILITY


1 FIRST ISSUE 27.01.23 AK
iHFG

International Health Facility Guidelines at: DESIGNED APPROVED SCALE(S) SHEET


International Health
DATE
www.healthdesign.com.au/ihfg
Editable version of Standard Components on
AK RH 27.01.23 1 : 50 2 OF 4

Facility Guidelines
Health Facility Briefing System (HFBS) at: REVIT FILE NAME PAPER DRAWING ID ISSUE
www.healthdesign.com.au ©TAHPI
or-ca-i or-ca-i-2 1
This document is for advisory purpose only
iHFG Standard Components
Room Layout Sheet

RLS Room Code or-ca-i


Room Name Operating Room - Cardiac RDS Room Code or-ca-i

GENERAL NOTES:
THIS DRAWING TO BE READ IN CONJUNCTION WITH R.D.S.
(ROOM DATA SHEETS) WHICH TAKES PRECEDENCE.

ALL SERVICES INDICATED ARE INDICATIVE AND SUBJECTED TO


DETAILED PROJECT SPECIFIC ENGINEERING DESIGN.

CEILING LEGEND:
CEILING TYPE
CORNICE TYPE
BP-PC2
2700 HEIGHT ABOVE F.F.L.

PBSR PLASTERBOARD FLUSH SET CEILING, SCRUB RESISTANT PAINT


FINISH
PBSR-PC2 PLASTERBOARD FLUSH SET CEILING, SCRUB RESISTANT PAINT
FINISHLINE
GRID WITH PLASTERBOARD CORNICE, FLUSHED COVED

ELECTRICAL LEGEND:

L/CC LIGHT - COLOUR CORRECTED

L/CCD LIGHT - COLOUR CORRECTED, DIMMABLE

MECHANICAL LEGEND:

HEPA FILTER GRILLE

FIRE SERVICES LEGEND:


SMOKE DETECTOR

SPRINKLER

CL OF ROOM
L/LA

PTZ

L/CCD L/CCD L/CCD L/CCD

PBSR-PC2
L/CC L/CC L/CC 3000

SETTING OUT OUT


PBSR
2200

POINT FOR SUP/A

2400
L/CC
L/CC

L/CCD L/CCD
SETTING OUT POINT
SETTING OUT FOR L/03CM2
CL OF ROOM

POINT FOR L/02M


L/CC

L/CC

PBSR
3000

2200
L/CC
L/CC

L/CCD L/CCD
L/CCD

SETTING OUT OUT


POINT FOR SUP/S
L/CC

L/CC

L/CC L/CC L/CC

L/CCD L/CCD L/CCD L/CCD

L/LA L/LA

REFLECTED CEILING PLAN

REV DESCRIPTION DATE BY REV DESCRIPTION DATE BY COMPATIBILITY


1 FIRST ISSUE 27.01.23 AK
iHFG

International Health Facility Guidelines at: DESIGNED APPROVED SCALE(S) SHEET


International Health
DATE
www.healthdesign.com.au/ihfg
Editable version of Standard Components on
AK RH 27.01.23 1 : 50 3 OF 4

Facility Guidelines
Health Facility Briefing System (HFBS) at: REVIT FILE NAME PAPER DRAWING ID ISSUE
www.healthdesign.com.au ©TAHPI
or-ca-i or-ca-i-3 1
This document is for advisory purpose only
iHFG Standard Components
Room Layout Sheet

RLS Room Code or-ca-i


Room Name Operating Room - Cardiac RDS Room Code or-ca-i

ISOMETRIC VIEW 1

ISOMETRIC VIEW 2

REV DESCRIPTION DATE BY REV DESCRIPTION DATE BY COMPATIBILITY


1 FIRST ISSUE 27.01.23 AK
iHFG

International Health Facility Guidelines at: DESIGNED APPROVED SCALE(S) SHEET


International Health
DATE
www.healthdesign.com.au/ihfg
Editable version of Standard Components on
AK RH 27.01.23 4 OF 4

Facility Guidelines
Health Facility Briefing System (HFBS) at: REVIT FILE NAME PAPER DRAWING ID ISSUE
www.healthdesign.com.au ©TAHPI
or-ca-i or-ca-i-4 1
This document is for advisory purpose only