Experience the Speed of light with

Reliable Transfer Switching Equipment

Catalogue 2023
1
ABOUT US

Havells India Limited a leading


Fast-Moving Electrical Goods (FMEG) Company

Over 6000 Professionals


over 17000 dealers and 35 branches
in the country & 15 state-of-the-art
manufacturing plants in India

Care 360
first FMEG Company to offer door
step service via its initiative

2
CONTENTS
InstaShift Manual Changeover Switches 4

InstaShift Motorized Changeover Switches 10

3
MANUAL
CHANGEOVER SWITCH
C

Designed to cater the need for


a new beginning in electrical distribution

4
The InstaShift Manual Changeover Switches
are manually operated four pole Changeover Switches,
having ratings 40 A to 800 A in 4 different frame sizes. The
main components of this changeover switch are proven
technology devices, fulfilling all the requirements for LV
distribution.

Suitable for Standards Conformity


Safe changeover, source inversion or switching ON-load IS / IEC 60947-3
between two low voltage power circuits as well as their safety
isolation. IS / IEC 60947-6-1

USPs
• 3 Stable Positions
• Staggered Terminals • Direct Aluminium Cable Connection
• Load and Line Reversibility • Easy wiring facilities for auxiliary switches
• Neutral Pole Interchangeability • 360° Mounting Orientation
• IP 43 Enclosure available • Voltage Sensing Kit for Automatic Transfer Switching Equipment

Product Salient Features


Safety Termination
q Power Control and Safety between q Shorting links mounted on all ratings
Primary and Secondary Source q Compact in size
q Fully Assembled and Tested Solution q Extended outgoing terminals
q Quick Make – Quick Break q Open Execution as well as in Enclosure
q Unaffected from typical Vibration and
Shock
q Provision of Phase Separators, Reliability
Source Separators and add-on q Switches are designed to be virtually
Auxiliary Switches
maintenance free across their entire
q Door Interlock and Padlock Facility extended lifespan and offer reliable
performance in any and all possible
circumstances.
Environmental Conditions​ q Durability has been ensured by testing
switches against the IS / IEC 60947-3
q IP Rating​ standard at stringent utilization category.
• IP2X against direct contact from front. q Minimal downtime with the possibility to
• IP32 in SS Enclosure versions. perform easy maintenance.
• IP43 available as an option on request.
Modularity
q Operating Conditions​ q Manual Transfer Switching Equipment can
be converted to RTSE/ATSE by adding
• Temperature: + 50 °C without derating.​
motor module as an accessory
• Hygrometry: 80% humidity at 55 °C, 95% humidity
at 40 °C without condensation.​
• Altitude: - Up to 2000 m without de-rating.​
5
Technical Characteristics

Unit

Rating A
Reference Standards
No. of Poles
No. of Breaks per pole
Electrical Characteristics
Rated Operational Voltage (Ue) VAC
Rated Insulation Voltage (Ui) V
Rated Impulse Withstand Voltage (Uimp) kV
Rated Frequency Hz
Pollution Degree

Conventional thermal current (Ith) at 50 °C A

Conventional enclosed thermal current (Ithe) at 50 °C A

Rated Operational Current (Ie) according to IEC 60947-3


415 VAC, AC-21A/ AC-22A/ AC-23A A
415 VAC, AC-21A/ AC-22A A
Rated Breaking Capacity for AC-23A A
Rated Making Capacity for AC-23A A
Rated Breaking Capacity for AC-22A / AC-21A A
Rated Making Capacity for AC-22A / AC-21A A
Short-time withstand (Icw), 1s kArms
Short-circuit making capacity, Icm kApeak
Mechanical Endurance O-I-O-II-O cycle
Electrical Endurance O-I-O-II-O cycle
Rated short-circuit current at 415 V, 50 Hz / 60 Hz kArms
Termination
Termination
Max. Al. cable with lug mm2
Max. link width mm
Max. link thickness mm
Termination tightening torque Nm
Installation and connection - Fixed, front connection
Installation
Wiring
Weight kg
As per IEC 60947-6-1
Class of Equipment
Rated short time withstand current Icw (r.m.s) 415 V,
kArms
0.03 s
Rated short time withstand current Icw (r.m.s) 415 V,
kArms
0.06 s
Short-circuit making capacity (Icm) kApeak
Rated Operational current (Ie):
415VAC, AC-31B A
415VAC, AC-32B A
415VAC, AC-33B A

6
IS00 IS02 IS04 IS06
IS00A IS00C IS02A IS02C IS04A IS04C IS06A IS06C
40 A, 63 A, 80 A, 100 A 125 A 125 A, 160 A, 200 A 250 A 250 A, 315 A 400 A 400 A, 630 A 800 A
IS / IEC 60947-3, IEC 60947-3, IS/IEC 60947-6-1, IEC 60947-6-1
FP
2

415 VAC
1000 V
6 kV 8 kV 12 kV 12 kV
50 Hz / 60 Hz
3 3 3 3
40 A 63 A 80 A 100 A 125 A 125 A 160 A 200 A 250 A 250 A 315 A 400 A 400 A 630 A 800 A

40 A 63 A 80 A 100 A 125 A 125 A 160 A 200 A 250 A 250 A 315 A 400 A 400 A 630 A 800 A

40 A 63 A 80 A 100 A - 125 A 160 A 200 A - 250 A 315 A - 400 A 630 A -


- - - - 125 A - - - 250 A - - 400 A - - 800 A
320 A 504 A 640 A 800 A 1000 A 1280 A 1600 A 2000 A 2520 A 3200 A 5040 A
400 A 630 A 800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3150 A 4000 A 6300 A
375 A 750 A 1200 A 2400 A
375 A 750 A 1200 A 2400 A
5 kArms 7 kArms 10 kArms 13 kArms
8 kApeak 12 kApeak 22 kApeak 26 kApeak
20000 16000 16000 10000
3000 2000 2000 2000
80 50 50 50 50

Unmarked Terminals
16 25 35 50 50 70 120 150 185 185 2x120 2x150 2x150 2x300 3x240
16 mm 22 mm 30 mm 40 mm 40 mm 50 mm 50 mm 60 mm
2 mm 4.7 mm 5 mm 8 mm 8 mm 2x8 mm 2x8 mm 2x10 mm
3.7 Nm 10 Nm 20 Nm 27 Nm

Mounting Bracket Mounting Bracket Mounting Bracket Mounting Bracket


Busbar / Cable Busbar / Cable Busbar / Cable Busbar / Cable
1.8 9 12 21.5

PC

5 - 10 10 -

- - - - 12.6

7.7 - 17 17 25.2

40 63 80 100 - 125 160 200 250 250 315 400 400 630 800
- - - - - - - - 250 315 400 400 500 630
- - - - - - - - - 200 200 200 200 400 400

7
Dimension
Open Execution
R

S
T
IS00 IS02 - IS06
DOOR DRILLING DOOR DRILLING
4.5
3

37
30
25
35.5
37 30

J J J
H
B

D
E
F
G

J J J K K C1

M
O

P N

Overall Dimensions (in mm)


Frame Rating (A)
A B C C1 D E F G H I J K L M N O P Q R S T
40/63/80/100 153 74 142.5 20.6 117.9 98 95 74 110 20.4 27 2.5 32.6 103.8 13 8.4 6.5 125.6 50.5 38.9 174.2
IS00
125 CD 153 74 142.5 20.6 117.9 98 95 74 110 20.4 27 2.5 32.6 103.8 13 8.4 6.5 125.6 50.5 38.9 174.2
125/160/200 248.2 112 188 21.6 160 137 143 100 160 27 48 3.2 47.2 142.9 22 8.5 8.5 205.9 125 53.2 234.8
IS02
250 CD 248.2 112 188 21.6 160 137 143 100 160 27 48 4 47.2 142.9 25 8.5 8.5 205.9 125 53.2 234.8
250/315 308 112 188 21.6 194 160 143 112 160 41 60 4 47.2 143.7 34 17 11.2 265.5 125 53.2 234.8
IS04
400 CD 308 112 188 21.6 213 179 143 112 160 51 66 4 47.2 143.7 40 17 11.2 265.5 125 53.2 234.8
400/630 338.2 112 235.2 21.6 260 230 190.9 160 220 50 70 6 60.7 184.4 44 15 12.5 294.3 153.9 55.3 319.8
IS06
800 CD 338.2 112 235.2 21.6 260 230 190.9 160 220 50 70 8 61.7 185.4 44 15 12.5 294.3 153.9 55.3 319.8

8
With Enclosure

Frame L M N O P Q
IS00 260 200 260 215 4.3 181
IS02 325 275 370 300 4.3 241
IS04 410 340 420 350 4.3 241
IS06 500 390 730 460 4.3 326

Exploded View
1. Changeover Switch

8 2. Line Terminals
6 3. Load Terminals
3
10 4. Contact Pocket
7
5. Mechanism Housing
11 6. Shorting Link
1
7. Mounting Bracket
4
13 8. Phase Separator
9. Source Separator
5 10. Cam Holding Housing Cover
15 14
11. Auxiliary Switches

2
12 12. Rotary Handle
13. Shaft
14. Cam
15. Center Shaft

9
MOTORIZED
CHANGEOVER SWITCH

Designed to maximize customer’s range of selection and


level of satisfaction

10
Dimensions MOTORIZED
CHANGEOVER SWITCH

The InstaShift Motorized Changeover Switches


are motor operated Four Pole Changeover Switches,
having ratings 125 A to 800 A in 3 different frame sizes. The
motorized design enables Precise Changeover and Smooth
Operation.

Suitable for Standards Conformity


Safe changeover, source inversion or switching ON-load IS / IEC 60947-3
between two low voltage power circuits as well as their safety
isolation. IS / IEC 60947-6-1

USPs
• 3 Stable Positions
• Staggered Terminals • Direct Aluminium Cable Connection
• Load and Line Reversibility • Easy wiring facilities for auxiliary switches
• Neutral Pole Interchangeability • 360° Mounting Orientation
• IP 43 Enclosure available • Voltage Sensing Kit for Automatic Transfer Switching Equipment

Exploded View

1. Changeover Switch
2. Motorized Unit
1
3. Dummy Cover
4. Emergency Handle

Fascia Description
4
3

1. Power LED – Indicating the ON / OFF status


of Motorized Changeover Switch.

2. Manual / Fault LED - Indicates the Manual


1 Mode or Fault occurs.
2
3. Auto / Manual / Padlock Indication – For
indicating the mode of operation.
7
3 6 4. Auto / Manual / Padlock Knob – Visual
Indication of Mode of Operation.

4 5. Padlock Lever

5 6. Emergency / Manual Handle

7. Position Window

11
Technical Characteristics
Unit

Rating A
Reference Standards
No. of Poles
No. of Breaks per pole
Electrical Characteristics
Rated Operational Voltage (Ue) VAC
Rated Insulation Voltage (Ui) (Power Circuit) V
Rated Insulation Voltage (Ui) (Control Circuit) V
Rated Impulse Withstand Voltage (Uimp) (Power Circuit) kV
Rated Impulse Withstand Voltage (Uimp) (Control Circuit) kV
Rated Frequency Hz
Pollution Degree
Data according to IEC 60947-3, IS / IEC 60947-3
Conventional thermal current (Ith) at 50 °C A
Conventional enclosed thermal current (Ithe) at 50 °C A
Rated Operational Current (Ie)
415 VAC, AC-21A/ AC-22A / AC-23A A
415 VAC, AC-21A/ AC-22A A
Rated Breaking Capacity for AC-23A A
Rated Making Capacity for AC-23A A
Rated Breaking Capacity for AC-22A / AC-21A
Rated Making Capacity for AC-22A / AC-21A
Short-time withstand (Icw), 1s kArms
Short-circuit making capacity, Icm kApeak
Rated short-circuit current at 415 V, 50 Hz / 60 Hz kArms
Mechanical Endurance O-I-O-II-O cycle
Electrical Endurance
Termination
Max. Al. cable with lug mm2
Max. link width mm
Max. link thickness mm
Termination tightening torque Nm
Weight kg
Data as per IS/IEC60947-6-1, IEC 60947-6-1
Conventional thermal current (Ith) at 50 °C A
Conventional enclosed thermal current (Ithe) at 50 °C A
Rated Operational current (Ie):
415 VAC, AC-31B A
415 VAC, AC-32B A
415 VAC, AC-33B A
Short-time withstand (Icw) for 30 ms kArms
Short-time withstand (Icw) for 60 ms kArms
Short-circuit making capacity (Icm) kApeak
Switching time (rated voltage, after receiving
command)
Time of transfer I-II or II-I s
I-0 or II-0 s
Time of contact transfer (black-out I-II) minimum s
Power supply
Min./max. power VAC
Control supply power demand
Demand/rated power VA
12
IS02 IS04 IS06
IS02A IS02C IS04A IS04C IS06A IS06C
125 A, 160 A, 200 A 250 A 250 A, 315 A 400 A 400 A, 630 A 800 A
IS / IEC 60947-3, IS/IEC 60947-6-1
FP
2

415 VAC
1000 V
300 V
8 kV 12 kV 12 kV
4 kV
50 Hz / 60 Hz
3

125 A 160 A 200 A 250 A 250 A 315 A 400 A 400 A 630 A 800 A
125 A 160 A 200 A 250 A 250 A 315 A 400 A 400 A 630 A 800 A

125 A 160 A 200 A 250 A 315 A 400 A 630 A


250 A 400 A 800 A
1000 A 1280 A 1600 A 2000 A 2520 A 3200 A 5040 A
1250 A 1600 A 2000 A 2500 A 3150 A 4000 A 6300 A
750 A 1200 A 2400 A
750 A 1200 A 2400 A
7 kArms 10 kArms 13 kArms
12 kApeak 22 kApeak 26 kApeak
50 kArms 50 kArms
16000 16000 10000
2000 2000 2000
Unmarked Terminals
70 120 150 185 185 2x120 2x150 2x150 2x300 3x240
30 mm 40 mm 40 mm 50 mm 50 mm 60 mm
5 mm 8 mm 8 mm 2x8 mm 2x8 mm 2x10 mm
10 Nm 20 Nm 27 Nm
9 kg 12 kg 21.5 kg

125 A 160 A 200 A 250 A 250 A 315 A 400 A 400 A 630 A 800 A
125 A 160 A 200 A 250 A 250 A 315 A 400 A 400 A 630 A 800 A

125 A 160 A 200 A 250 A 250 A 315 A 400 A 400 A 630 A 800 A
- - - - 250 A 315 A 400 A 400 A 500 A 630 A
200 A 200 A 200 A 200 A 400 A 400 A
10 kArms 10 kArms -
- - 12.6 kArms
17 kApeak 17 kApeak 25.2 kApeak

0.8 s 0.9 s
0.5 s
0.3 s 0.4 s

166 VAC / 332 VAC

276 VA / 138 VA 230 VA / 105 VA 253 VA / 115 VA


13
Connectors Description

Control Inputs
[Pin 31: Remote Mode]
The remote mode is active when Pin 31 (Ctrl) is closed with pin 36 (C). Only when pin 31 is closed with 36 other inputs 33, 34 and 35
are activated.

NOTE: Pin 32 (OFF) is an exception and its activation state doesn’t depends on the state of 31. Even if 31 is not closed with 36, pin
32 will remain active.
Action on pin 32 is having priority over actions on other input pins.

[Pin 32: OFF Mode]


The OFF pin (32) when closed with pin 36 transfers the switch to position 0. In more accurate words, it forces the switch to go to OFF
position (0 position).
Pin 32 is having priority input over all other pins inputs and commands. No other inputs will work till 32-36 remains closed. Impulse
duration to activate command is 60ms minimum.

[Pin 33: Position II Command]


Pin 33 closed with pin 36 transfers the switch to position II. This input works when 31-36 is also closed.
Impulse duration to activate command is 60ms minimum. This input is a RTSE functionality.

[Pin 34: Position I Command]


Pin 34 closed with pin 36 transfers the switch to position I. This input works when 31-36 is also closed.
Impulse duration to activate command is 60 ms minimum. This input is a RTSE functionality.

[Pin 35: Position 0 Command]


Pin 35 closed with pin 36 transfers the switch to position 0. This input works when 31-36 is also closed.
Impulse duration to activate command is 60ms minimum. This input is a RTSE functionality.

For contactor logic, keep pins 35-36 closed.


In maintained mode when an order is sent it will be maintained until a different order is sent.

Output Status
[Pin 41|42: Product available output]
Pin 41|42 is a normally open contact which remains closed when the product is available to operate.
This contact gives the feedback about the product availability and its capacity to be operated remotely or automatically.

[Pin 43: Common] Common pin to be used with pin 44, 45, 46

[Pin 44: Position 0 Status] Pin 44 closed with pin 43 shows the Position 0 of the RTSE. This signal can be used for LED/buzzer etc.

[Pin 45: Position II Status] Pin 45 closed with pin 43 shows the Position II of the RTSE. This signal can be used for LED/buzzer etc.

[Pin 46: Position I Status] Pin 46 closed with pin 43 shows the Position I of the RTSE. This signal can be used for LED/buzzer etc.

Power Connector
InstaShift RTSE is to be powered between terminals 8 and 9 with a supply within the limits of:
208 Vac – 277 Vac ± 20% (166 Vac – 332 Vac) 50 Hz / 60 Hz ±10%
14
Auto / Manual / Padlock Knob
There are three different Modes of Operation of Switch; Manual Mode, Automatic Mode and Padlock Mode. This knob is
to provide visual indication for different Modes of Operation of Changeover Switch.

Manual Mode
(Fault LED will
activate in this position)
Auto Mode

Padlock Mode*

This lever to
be pulled for
padlocking
*Padlock can be put in this condition

Wiring Diagram
Source I Source II
To Load
N L1 L2 L3 L3 L2 L1 N

Connect the product with


a cable of section of 1.5 mm2 RTSE
to 2.5 mm2. 8
9
Screw M3 - Tightening
torque: min.: 0.5 Nm -
max.: 0.6 Nm
31 32 33 34 35 36 41 42 43 44 45 46

CONTROL INPUTS OUTPUT STATUS

Output Status
Control Inputs Product
240 V / 2A
24 V / 2 A

Ctrl OFF II I O C Available C O II I

41 42 43 44 45 46
31 32 33 34 35 36

15
Dimension
Open Execution
A
H
B B B

CONTROL CONNECTION
& DISCONNECTION AREA
C

J
D

B B B K TRIPLE PADLOCK TAB


L

E M
N

G
F

R R
Q
P
O

HANDLE 124
48
86

16
With Enclosure

S 34
T W 19
U
V

DOOR CUTOUT
192 20
67
55
112

36
38

Frame Rating
Overall Dimnesions
(A)
A B C D E F G H I J K L M N O P Q R S T U V W
125 339 48 137 154 22 27 347 205.9 143 100 6.2 8.5 8.5 158 253 143 47 3.2 435 375 300 370 250
160 339 48 137 154 22 27 347 205.9 143 100 6.2 8.5 8.5 158 253 143 47 3.2 435 375 300 370 250
IS02
200 339 48 137 154 22 27 347 205.9 143 100 6.2 8.5 8.5 159 253 143 47 3.2 435 375 300 370 250
250 CD 339 48 137 154 22 27 347 205.9 143 100 6.2 8.5 8.5 160 253 143 47 4 435 375 300 370 250
250 399 60 160 194 34 41 245 265.5 143 112 6.2 17 11.2 160 253 144 47 4 511 430 350 420 250
IS04 315 399 60 160 194 34 41 245 265.5 143 112 6.2 17 11.2 160 253 144 47 4 511 430 350 420 250
400 CD 405 66 179 213 40 50 285 265.5 143 112 6.2 17 11.2 160 253 144 47 4 511 430 350 420 250
400 429 70 230 260 44 50 407 294.3 190.9 160 8.2 15 12.5 220 300 184 61 6 565 472 460 730 298
IS06 630 429 70 230 260 44 50 407 294.3 190.9 160 8.2 15 12.5 220 300 184 61 6 565 472 460 730 298
800 CD 429 80 250 295 50 50 407 294.3 190.9 160 8.2 22.5 12.5 220 300 185.4 61.7 8 565 472 460 730 298

17
Ordering Code - Manual Changeover Switch

Open Execution SS Enclosure Version


Frame Rating (A) Catalogue Code Frame Rating (A) Catalogue Code
40 IHCCFO0040 40 IHCCFE0040
63 IHCCFO0063 63 IHCCFE0063
IS00 IS00
100 IHCCFO0100 100 IHCCFE0100
125* IHCPFO0125 125* IHCPFE0125
125 IHCCFO0125 125 IHCCFE0125
160 IHCCFO0160 160 IHCCFE0160
IS02 IS02
200 IHCCFO0200 200 IHCCFE0200
250* IHCPFO0250 250* IHCPFE0250
250 IHCCFO0250 250 IHCCFE0250
IS04 315 IHCCFO0315 IS04 315 IHCCFE0315
400* IHCPFO0400 400* IHCPFE0400
400 IHCCFO0400 400 IHCCFE0400
IS06 630 IHCCFO0630 IS06 630 IHCCFE0630
800* IHCPFO0800 800* IHCPFE0800
*Compact Design

Ordering Code - Motorised Changeover Switch

Open Execution SS Enclosure Version


Frame Rating (A) Catalogue Code Frame Rating (A) Catalogue Code
125 IHLFNAO125 125 IHLFNAE125
160 IHLFNAO160 160 IHLFNAE160
IS02 IS02
200 IHLFNAO200 200 IHLFNAE200
250* IHLFNAO25D 250* IHLFNAE25D
250 IHLFNAO250 250 IHLFNAE250
IS04 315 IHLFNAO315 IS04 315 IHLFNAE315
400* IHLFNAO40D 400* IHLFNAE40D
400 IHLFNAO400 400 IHLFNAE400
IS06 630 IHLFNAO630 IS06 630 IHLFNAE630
800* IHLFNAO80D 800* IHLFNAE80D
*Compact Design

18
AUTOMATIC
TRANSFER SWITCH

Designed for safe changeover, source inversion


or switching ON-load between two low voltage power
circuits as well as their safety isolation

19
AUTOMATIC
TRANSFER SWITCH

Today the needs are increasing for a reliable and independent


power changeover system during power failures. In
such event, the stand-by power is expected to take
over automatically which is achieved efficiently by
Automatic Transfer Switch. The InstaShift Automatic Changeover
Switches enable Precise Changeover and Smooth Operation
through motor operated mechanism. Range comprises of 125
A to 800 A Four Pole Changeover Switches in 3 different frame
sizes.

• Available with 3 different controllers - B Type, M Type, H Type Standards Conformity


• Provision For Unit / Door Mountable HMI Kit
IS / IEC 60947-3
IS / IEC 60947-6-1

Exploded View - B Type

1. Changeover Switch
2. Motorized Unit
1
3. Display Module B Type
4 4. Emergency Handle
3

Salient Features (B Type): Salient Features (M Type):


• Allows Mode of Operations like Auto, Remote and Manual • Offers LCD Display
• Offers Protection by Switching in case of : • Allows Password Protection
- Phase Missing
- Voltage unbalance • Gives Alarm for Key Protection Parameters

• Allows Setting for : • Offers measurement of Line & phase voltage and Frequency
- Under and Over Voltage
- Under and Over Frequency

Exploded View - M Type

1. Changeover Switch
1 2. Motorized Unit
3. Display Module M
Type
4. Emergency Handle
4 3

20
Exploded View - H Type
Salient Features:
• Remote connectivity enabling monitoring and controlling
• Feasibility of remote configuration through Cloud
• Wi-Fi connectivity
• Wired ETHERNET for achieving real-time monitoring and display of energy parameters
• Data logger showing event history
• Multiple ports for communication with genset control module: RS485, RS232
• Parameters adjust function: users can adjust parameters via USB port

1. Changeover Switch

2. Motorized Unit

3. High End Module

4. Emergency Handle
4

21
Accessories - MTSE
Castell Lock

Code Item Description


ISSCNX0218 Castell Lock Frame IS00
ISSCNX0217 Castell Lock Frame IS02 / IS04 / IS06

Auxiliary Switch

Code Item Description


ISCELQOX0074 Auxiliary Switch Assembly 2NO 2NC Frame IS00
ISCELQOX0076 Auxiliary Switch Assembly 2NO 2NC Frame IS02, IS04 & IS06

Direct Handle Conversion Kit

Code Item Description


ISSCNX0235 Direct Handle IS00
ISSCNX0221 Direct Handle IS02-IS04-IS06

Enclosure for MTSE (with IP 43)*

Code Item Description


ISSCNX0192 Enclosure Frame IS00
ISSCNX0191 Enclosure Frame IS02
ISSCNX0190 Enclosure Frame IS04
ISSCNX0189 Enclosure Frame IS06

*Available on request

22
Accessories - RTSE
MTSE to RTSE Conversion Kit

Code Item Description


ISSCNX0211 MOTOR MODULE 125A-400A CD
ISSCNX0212 MOTOR MODULE 400A-800 A CD

Enclosure for RTSE (with IP 32)

Code Item Description


ISSCNX0204 Enclosure Frame IS02
ISSCNX0205 Enclosure Frame IS04
ISSCNX0206 Enclosure Frame IS06

Enclosure for RTSE (with IP 43)*

Code Item Description


ISSCNX0256 Enclosure Frame IS02
ISSCNX0257 Enclosure Frame IS04
ISSCNX0258 Enclosure Frame IS06

*Available on request

23
REGIONAL & BRANCH OFFICES:
NORTH - REGIONAL OFFICE: Corporate Office: QRG Towers, 2D, Sector-126, Expressway, Noida-201304, Tel: 0120-3331000, Delhi: 011-47676700, 23888200, Chandigarh: 0172-4232400-401,
Dehradun: 0135-6670202, Haldwani: 05946-222935/222933, Noida / Haryana: 0120-3331000, Ludhiana: 0161-4676000/24,
Amritsar: 0183-5202400/401, Jammu: 0191-2478330, 2479330, Sri Nagar: 0194-2459248, Jaipur: 0141-4211000, 4211011, Jodhpur: 9214201640/41,
Lucknow: 0522- 4921600/4921649, Kanpur: 0512-6710400
EAST - REGIONAL OFFICE: Kolkata: ICC Tower, 5th Floor, 4 India Exchange Place, Kolkata-700001, Tel: 033-40129851/52, Bhubaneshwar: 0674-6668101/102/103/104, Guwahati: 0361-2458923,
2134521, Siliguri: 0353-2525907, Ranchi: 0651-2244861, 2244862, 2244864, 2244868, 2244869, Jamshedpur: 0657-6542492, 09234369436, Patna: 0612-2207221, 2207222, 2207223, 2655518
WEST - REGIONAL OFFICE: 1271, Solitaire Corporate Park, Bldg. No. 12, 7th Floor, Andheri - Ghatkopar Link Road, Chakala, Andheri (East), Mumbai- 400093.
Tel: 022 - 67298600-602, Ahmedabad: 079-40061111, 40060738/740, Indore: 0731-4219444/4219422, 0731-2572340, Rajkot: 0281-2481112, 2921212, Nagpur: 0712-2240932, 2242692, 2242699
Pune: 020-26056175-76, Raipur: 0771-4243400/01, Surat: 0261-2350137, 9979890137, Jabalpur: 0761-4064491, Bhopal: 0755-4271544, 0755-4011025,
SOUTH - REGIONAL OFFICE: Chennai: Sigapi Achi Building, No. 18 / 3, 6th Floor, Rukmani Lakshmipathy Road, Egmore, Chennai-600008, Tel: 044-42280600, 605, Bangalore: 080-49075000,
Coimbatore: 0422-4550200/282, Hyderabad: 040-27533372, 27533355, 27533632, Cochin: 0484-4099000, Calicut: 0495-4019193/4/5, Trivandrum: 0471-4015323, Vizag: 0891-6514339,
Vijayawada: 0866-2546161/62/67/68/69, Madurai: 0452-4267000, Hubli: 0836-4248660, Trichy: 0431-4041005/06
Representative Offices: • Goa • Solapur • Gwalior • Kathmandu • Bhopal • Kolapur • Vadodara
Warranty Policy: Terms & Conditions
All the products listed in the price list carry a warranty, against manufacturing  Prices are in Indian `.
defects for a period of 18* months from the date of purchase / 12 months  This Price List supersedes all our previous Price Lists.
from the date of commissioning, whichever is earlier.  Prices are subject to change without notice.
*Proof of purchase to be retained to avail warranty.  Company reserves the right to issue amendments, which may arise due to any errors in the price list.

Actual products may vary in colour, design, description and colour combination etc. Although every effort has been made to ensure accuracy in the compilation of the technical detail within this
publication. Specifications & performance data are constantly changing.
“Copyright Subsists. Imitation of trade dress, graphics and color scheme of this document is a punishable offence.”

Note: All Products to be billed at 18% *GST (Subject to change as per Govt. Notification).

Havells India Ltd.


Corp Office: QRG Towers, 2D, Sector-126, Expressway, Noida-201304 (U.P.)
Ph. +91-120-3331000, Email:marketing@havells.com, www.havells.com
Customer Care No.: 08045 77 1313
Join us on Facebook at www.facebook.com/havells and share your ways to save planet!
CIN - L31900DL1983PLC016304

You might also like