CC-BCD: T00W2DHM
CC-BCD: T00W2DHM
CC-BCD
T00W2DHM Page: 1 /2
TASK INFORMATION
OEM Part Number Serial Nº Effective Code Task Priority
Panels Zones
196BB - Yellow hydraulic bay. (Access to the same 190 - BELLY FAIRING, AIR CONDITIONING AND
components as through 196 AB) HYDRAULKICS COMPARTMENT
195BB - Blue hydraulic bay. (Access to the same 500 - Left Wing
components as through 195 AB)
DESCRIPTION
(LH WING) TANKS
NOTE:
INTERVAL:
- DEPENDING ON OPERATING ENVIRONMENT AND OPERATORS
EXPERIENCE, A LESS FREQUENT OR MORE FREQUENT
INITIAL INTERVAL MAY BE USED.
Enginnering Instructions
AMM TASK 12-32-28-281-001-A AMM REV. 49,01 May 2025
Action Taken
1. herman german izquierdo suarez, 03- PERFORMED LH DRAIN WATER CONTENT IAW AMM TASK 12-32-28-281-001-A. REV 49
SEP-2025 07:12 SATISFACTORY
PARTS ON/OFF
TOOLS
SIGNATURE
The signer(s) below certifies that the work has been completed satisfactorily
STEP 1
AMM TASK 12-32-28-281-001-A Accomplished By
Drain Water Content STATUS: Complete
WARNING: MAKE SURE THAT THE SAFETY DEVICES AND THE WARNING NOTICES ARE IN POSITION BEFORE
YOU START A TASK ON OR NEAR:
herman german
izquierdo suarez
- THE FLIGHT CONTROLS
A320
- THE FLIGHT CONTROL SURFACES
WARNING: BE CAREFUL NOT TO GET AIRCRAFT FUEL IN YOUR MOUTH OR IN YOUR EYES.
IF YOU GET FUEL ON YOUR SKIN OR ON YOUR CLOTHES, FLUSH IT IMMEDIATELY WITH WATER.
You can do this task together with TASK 12-32-28-281-003-A (Sample Fuel for
Microbiological Contamination Analysis) and TASK 12-32-28-281-802-A (Sample Fuel for
Hydraulic-Oil Contamination Analysis). If you are sampling for microbiological
contamination of fuel do task 12-32-28-281-003-A instead of this task. If you do the
Microbiological/Hydraulic-Oil Contamination Analysis, you must clean the applicable drain
tool and the container as given in the AMM tasks.
NOTE: If possible, Airbus recommends you to do the water drain procedure before the flight or the refuel procedure.
If you do this procedure after the flight or the refuel procedure, you must wait for one hour for the separation of the
water and the fuel.
NOTE: It is permitted to do this procedure when the APU is in operation only if the fuel tank pumps are set to
OFF.
If you have less than 10% content of the fuel, then the indirect water drain-valves will
have a decreased flow.
If you have less than 10% content of the fuel it is recommended that you fill more fuel or
use the suction procedure.
Uplift of additional fuel is not required for the operation of direct water drain-valves.
No specific AR HYDROKIT
97A28002117002 1 TOOL-PURGING
195BB
196BB
C. Referenced Information
REFERENCE DESIGNATION
Cold Weather
12-31-28-660-001-A Maintenance -
Fuel
Deactivation of
the VHF
23-12-00-040-802-A
Antenna for
Maintenance
Reactivation of
the VHF
23-12-00-440-802-A
Antenna After
Maintenance
Fuel Safety
28-00-00-910-001-A
Procedures
** On A/C 001-009 011-050 101-150 154-200 246-300 351-352 356-356 358-372 378-379
381-400 501-501 503-504 506-506 508-508 510-512 517-525 527-527 529-529 531-536
540-550 561-567 571-571 582-600 605-608 610-611 615-709 712-712 717-718 725-725
729-750 901-908 911-951 953-957 960-999
(Ref. Fig 12-32-28-991-00100-00-B - Fuel Sampling For Analysis)
** On A/C ALL
** On A/C 401-425 427-428 430-433 435-450 801-900
(Ref. Fig 12-32-28-991-00100-00-C - Fuel Sampling For Analysis)
** On A/C ALL
** On A/C 001-009 011-050 101-150 154-200 246-300 351-352 356-356 358-372 378-379
381-400 501-501 503-504 506-506 508-508 510-512 517-525 527-527 529-529 531-536
540-550 561-567 571-571 582-600 605-608 610-611 615-709 712-712 717-718 725-725
729-750 901-908 911-951 953-957 960-999
(Ref. Fig 12-32-28-991-00700-00-B - Fuel Sampling For Analysis - Suction Procedure)
** On A/C ALL
** On A/C 401-425 427-428 430-433 435-450 801-900
(Ref. Fig 12-32-28-991-00700-00-C - Fuel Sampling For Analysis - Suction Procedure)
** On A/C ALL
STEP 2
Accomplished By
** On A/C ALL
STATUS: Complete
3. Job Set-up
** On A/C 001-009 011-050 101-150 154-200 246-300 351-352 356-356 358-372 378-379 381-400 501-501 503-504 herman german
506-506 508-508 510-512 517-525 527-527 529-529 531-536 540-550 561-567 571-571 582-600 605-608 610-611 izquierdo suarez
615-709 712-712 717-718 725-725 729-750 901-908 911-951 953-957 960-999
A320
(Ref. Fig 12-32-28-991-00100-00-B - Fuel Sampling For Analysis)
** On A/C 401-425 427-428 430-433 435-450 801-900 Lic. No.: 6040
(Ref. Fig 12-32-28-991-00100-00-C - Fuel Sampling For Analysis) 03/09/2025 07:12:29
** On A/C ALL (UTC)
SUBTASK 12-32-28-040-052-A
STEP 3
Accomplished By
SUBTASK 12-32-28-941-054-B
STATUS: Complete
B. Safety Precautions
herman german
WARNING: OBEY THE FUEL SAFETY PROCEDURES. THIS CAN PREVENT INJURY AND DAMAGE.
izquierdo suarez
(1) You must obey the fuel safety procedures when you do work on the fuel system (Ref. TASK 28-00-00-910-001-
A). A320
(2) As necessary, use the applicable SAFETY BARRIER(S), specified by the operator's Lic. No.: 6040
instructions and your local regulations.
03/09/2025 07:12:29
(3) In the cockpit, on panel 400VU:
(UTC)
Make sure that the landing-gear control-lever 6GA is in the DOWN
position
(4) Put the WARNING NOTICE(S) in position to tell persons not to operate the landing
gear doors.
(5) If the fuel temperature is less than 0 DEG.C (32.00 DEG.F) and/or the water drain
valves are frozen, to keep the flight turnaround times, one of the two steps that
follow:
(6) If the APU is in operation during this procedure, you must make sure that the fuel
tank pumps are set to OFF.
STEP 4 - N/A
Accomplished By
SUBTASK 12-32-28-010-050-B
STATUS: N/A
C. Get Access
herman german
(1) To get access to the center-tank water-drain valves, open the applicable access izquierdo suarez
door:
A320
(a) FOR 94QM (VALVE-WATER DRAIN, L CTR TK)
Lic. No.: 6040
Open access door 195BB.
03/09/2025 07:12:29
(b) FOR 95QM (VALVE-WATER DRAIN, R CTR TK) (UTC)
Open access door 196BB.
STATUS NOTE:
STEP 5
Accomplished By
SUBTASK 12-32-28-480-050-A
STATUS: Complete
D. Preparation of the Equipment
herman german
(1) To get access to the high water drain valves from the ground, attach the: izquierdo suarez
ADAPTING PIPE - WATER DRAINING FROM FUEL A320
(98A28101000000)
or the Lic. No.: 6040
PIPE ADAPTING-WATER DRAINING (98D28104000000) 03/09/2025 07:12:29
to the bottle and funnel of the PURGER-WATER DRAIN (UTC)
(98A28104000000).
STEP 6
Accomplished By
** On A/C 001-009 011-050 101-150 154-200 246-300 351-352 356-356 358-372 378-379 381-400 501-501 503-504
506-506 508-508 510-512 517-525 527-527 529-529 531-536 540-550 561-567 571-571 582-600 605-608 610-611 STATUS: Complete
615-709 712-712 717-718 725-725 729-750 901-908 911-951 953-957 960-999
herman german
(Ref. Fig 12-32-28-991-00100-00-B - Fuel Sampling For Analysis)
izquierdo suarez
(Ref. Fig 12-32-28-991-00700-00-B - Fuel Sampling For Analysis - Suction Procedure)
A320
** On A/C 401-425 427-428 430-433 435-450 801-900
Lic. No.: 6040
(Ref. Fig 12-32-28-991-00100-00-C - Fuel Sampling For Analysis)
03/09/2025 07:12:29
(Ref. Fig 12-32-28-991-00700-00-C - Fuel Sampling For Analysis - Suction Procedure)
(UTC)
** On A/C ALL
STEP 7
Accomplished By
** On A/C ALL
STATUS: Complete
SUBTASK 12-32-28-281-050-B
herman german
A. Fuel Sampling for Water Contamination
izquierdo suarez
(1) Gravity Procedure:
A320
(a) For the gravity procedure, you can use the TOOL-PURGING
(97A28002117002) to drain the fuel from the wing tanks and the centre tank, but Lic. No.: 6040
it does not prevent leaks. 03/09/2025 07:12:29
1 It is recommended to use the TOOL - PURGING (98A28104000002) to drain (UTC)
the fuel from the centre tank and the PURGER-WATER DRAIN
(98A28104000000) to drain the fuel from the wing tanks.
(b) For indirect water drain-valves, make sure that the fuel tanks are filled to a
minimum of 10% of capacity. This is necessary to cover the water drain-valve
outlet, so that the water drain valves can operate satisfactorily.
1 Push the center of the applicable water drain valve with the PURGER-WATER
DRAIN (98A28104000000):
a Drain approximately 1.0 l (0.26 USgal) of fuel from the water drain valve.
NOTE: The surge tanks are the temporary tanks that are made to collect fuel that can overflow from the vent lines.
Usually, no fuel can be drained from the surge tanks.
1 Push the center of the applicable water drain valve with the TOOL -
PURGING (98A28104000002):
a Drain approximately 1.0 l (0.26 USgal) of fuel from the water drain valve.
a If the water drain valve does leak, use the TOOL - PURGING
(98A28104000002) to push (in) and release (out) the center of the
valve three or four times.
(f) Do the sample removal procedure at all the water drain valves.
(a) If you use the TOOL-PURGING (97A28002117002), do the steps that follow:
3 Put the hexagonal end of the bush (2) into the bottom of the water drain valve.
5 Turn the nut (5) until it touches and seals against the bottom skin.
8 Hold the bush (2) and turn the screw (4) clockwise to its stop:
a This causes the plunger (1) to open the drain valve. Fuel can now flow
into the PUMP - SUCTION (ATEX APPROVED).
10 Continuously monitor the fuel flow into the CONTAINER 10 L(2 1/2 USGAL).
11 Drain approximately 1.0 l (0.26 USgal) of fuel (as a sample) from the drain
valve.
NOTE: The surge tanks are the temporary tanks that are made to collect fuel that can overflow from the vent lines.
Usually, no fuel can be drained from the surge tanks.
12 When you drained sufficient fuel sample, turn the screw (4) counter
clockwise to its stop.
14 Remove the PUMP - SUCTION (ATEX APPROVED) from the hose (3).
15 Turn the nut (5) until it does not touch the bottom skin.
16 Turn the hexagonal end of the bush (2) to 30 deg (30 deg):
(b) If you use the PURGER-WATER DRAIN (98A28104031001), do the steps that
follow:
CAUTION: MAKE SURE THAT THE PLUNGER OF THE TOOL ALIGNS CORRECTLY WITH THE WATER DRAIN
VALVE. INCORRECT ALIGNMENT OF THE TOOL CAN CAUSE:
THE WATER DRAIN VALVE TO STAY IN THE OPEN POSITION AFTER THE TOOL IS REMOVED
A FUEL LEAK.
1 Push the center of the applicable water drain valve with the PURGER-WATER
DRAIN (98A28104031001).
3 Continue to operate the water drain valve until only fuel comes out.
a If the water drain valve does leak, use the PURGER-WATER DRAIN
(98A28104031001) to push (in) and release (out) the center of the
valve three or four times.
(3) Do a test for the microbiological contamination in less than 10 days, if:
(a) You can see brown slimy, white particles and/or sludge in the sample that you
drain from the tank.
(b) You can see particles in the sample (Ref. TASK 12-32-28-281-003-A).
STEP 8
Accomplished By
SUBTASK 12-32-28-750-050-A
STATUS: Complete
B. Water Contamination Test
herman german
NOTE: This procedure gives the instructions to find the water content in the drained
sample. izquierdo suarez
This procedure is applicable to find out if the drained sample contains A320
water.
(a) If the sample moves into two layers it contains water. Drain the water from the
03/09/2025 07:12:29
water drain valve continuously until it has no water. (UTC)
WARNING: DO THE TEST ONLY IN AN APPROVED AREA. THIS WILL HELP TO PREVENT CONTAMINATION
AND EXPLOSIONS.
(b) If the sample stays in one layer, it can be full of fuel or full of water. To find if the
sample is fuel or water, do the test that follows:
If you test for the microbiological contamination, do not use the HYDROKIT
or put other material in the fuel (if not water).
ACTION RESULT
If the powder stays white, then
the sample is fuel and the test is
complete.
or
1.If you have the HYDROKIT available, then put the
contents into the sample. If the white powder changes color
to purple, the sample is water.
or
2.If you do not have the HYDROKIT available, then add
water to the sample. If the sample stays in one layer,
then the sample is water.
STEP 9 - N/A
Accomplished By
5. Close-up STATUS: N/A
SUBTASK 12-32-28-410-050-B
herman german
A. Close Access izquierdo suarez
(1) Make sure that the work area is clean and clear of tools and other items. A320
(2) Close the applicable access door: Lic. No.: 6040
(a) FOR 94QM (VALVE-WATER DRAIN, L CTR TK) 03/09/2025 07:12:29
(UTC)
Close access door 195BB.
STATUS NOTE:
STEP 10
Accomplished By
SUBTASK 12-32-28-942-050-A
STATUS: Complete
B. Removal of Equipment
herman german
(1) Make sure that the work area is clean and clear of tools and other items. izquierdo suarez
NOTE: To discard the water samples, refer to the local regulations.
A320
(2) Remove the safety barriers.
Lic. No.: 6040
(3) Remove the WARNING NOTICE(S).
03/09/2025 07:12:29
(4) Remove the ground support and maintenance equipment, the special and standard (UTC)
tools and all other items.
STEP 11
Accomplished By
SUBTASK 12-32-28-440-050-A
STATUS: Complete
C. Reactivation of the VHF Antenna
herman german
(1) If deactivated, do the reactivation of the VHF antenna after maintenance (Ref. TASK 23-12-00-440-802-A).
izquierdo suarez
A320
Lic. No.: 6040
03/09/2025 07:12:29
(UTC)
23QM
(24QM) A
21QM
(22QM)
94QM 95QM
A RIB15
RIB16
RIB22
RIB23
WATER
FUEL TANK
DRAIN VALVE
BOTTOM-SKIN
PLUNGER B
PURGING TOOL
98A28104000000 A
TYPICAL
B 01
NOTE:
0 1 CORRECT ALIGNMENT OF THE PLUNGER WITH THE WATER DRAIN VALVE. N_MM_123228_3_ACM0_01_02
Page 1 of 8
Fuel Sampling For Analysis : Fuel Sampling For Analysis - Sheet 1
On A/C 001-009 011-050 101-150 154-200 246-300 351-352 356-356 358-372 378-379 381-400 501-501 503-504 506-506 508-508 510-512 517-525
527-527 529-529 531-536 540-550 561-567 571-571 582-600 605-608 610-611 615-709 712-712 717-718 725-725 729-750 901-908 911-951 953-957
960-999
FUEL TANK D
BOTTOM-SKIN
PLUNGER
C
TYPICAL
PURGING TOOL
98A28104000002
D 01
NOTE:
0 1 CORRECT ALIGNMENT OF THE PLUNGER WITH THE WATER DRAIN VALVE. N_MM_123228_3_ACM0_02_01
Page 2 of 8
Fuel Sampling For Analysis : Fuel Sampling For Analysis - Sheet 2
On A/C 001-009 011-050 101-150 154-200 246-300 351-352 356-356 358-372 378-379 381-400 501-501 503-504 506-506 508-508 510-512 517-525
527-527 529-529 531-536 540-550 561-567 571-571 582-600 605-608 610-611 615-709 712-712 717-718 725-725 729-750 901-908 911-951 953-957
960-999
RIB2
25QM
C (26QM)
A
21QM
(22QM)
94QM 95QM
A
RIB22
RIB23
WATER
FUEL TANK
DRAIN VALVE
BOTTOM-SKIN
PLUNGER B
PURGING TOOL
98A28104000000 A
TYPICAL
B 01
NOTE:
0 1 CORRECT ALIGNMENT OF THE PLUNGER WITH THE WATER DRAIN VALVE. N_MM_123228_3_SAM0_01_02
Page 3 of 8
Fuel Sampling For Analysis : Fuel Sampling For Analysis - Sheet 1
On A/C 401-425 427-428 430-433 435-450 801-900
FUEL TANK D
BOTTOM-SKIN
PLUNGER
C
TYPICAL
PURGING TOOL
98A28104000002
D 01
NOTE:
0 1 CORRECT ALIGNMENT OF THE PLUNGER WITH THE WATER DRAIN VALVE. N_MM_123228_3_SAM0_02_01
Page 4 of 8
Fuel Sampling For Analysis : Fuel Sampling For Analysis - Sheet 2
On A/C 401-425 427-428 430-433 435-450 801-900
RIB2
25QM
(26QM)
A C
A C
23QM
(24QM)
21QM
(22QM)
94QM 95QM
A C RIB15
RIB16
RIB22 WATER DRAIN VALVE
RIB23
B
1
5
PURGING TOOL
2 97A28002117002
4
3
A
TYPICAL
B 01
NOTE:
0 1 CORRECT ALIGNMENT OF THE PLUNGER WITH THE WATER DRAIN VALVE. N_MM_123228_3_ANM0_01_04
Page 5 of 8
Fuel Sampling For Analysis - Suction Procedure : Fuel Sampling For Analysis - Suction Procedure - Sheet 1
On A/C 001-009 011-050 101-150 154-200 246-300 351-352 356-356 358-372 378-379 381-400 501-501 503-504 506-506 508-508 510-512 517-525
527-527 529-529 531-536 540-550 561-567 571-571 582-600 605-608 610-611 615-709 712-712 717-718 725-725 729-750 901-908 911-951 953-957
960-999
FUEL TANK
BOTTOM-SKIN
PLUNGER
C
TYPICAL
WATER DRAIN
PURGER
D 01
NOTE:
0 1 CORRECT ALIGNMENT OF THE PLUNGER WITH THE WATER DRAIN VALVE. N_MM_123228_3_ANM0_02_01
Page 6 of 8
Fuel Sampling For Analysis - Suction Procedure : Fuel Sampling For Analysis - Suction Procedure - Sheet 2
On A/C 001-009 011-050 101-150 154-200 246-300 351-352 356-356 358-372 378-379 381-400 501-501 503-504 506-506 508-508 510-512 517-525
527-527 529-529 531-536 540-550 561-567 571-571 582-600 605-608 610-611 615-709 712-712 717-718 725-725 729-750 901-908 911-951 953-957
960-999
RIB2
25QM
(26QM)
A C
A C
21QM
(22QM)
94QM 95QM
A C
RIB22 WATER DRAIN VALVE
RIB23
B
1
5
PURGING TOOL
2 97A28002117002
4
3
A
TYPICAL
B 01
NOTE:
0 1 CORRECT ALIGNMENT OF THE PLUNGER WITH THE WATER DRAIN VALVE. N_MM_123228_3_AQM0_01_04
Page 7 of 8
Fuel Sampling For Analysis - Suction Procedure : Fuel Sampling For Analysis - Suction Procedure - Sheet 1
On A/C 401-425 427-428 430-433 435-450 801-900
FUEL TANK
BOTTOM-SKIN
PLUNGER
C
TYPICAL
WATER DRAIN
PURGER
D 01
NOTE:
0 1 CORRECT ALIGNMENT OF THE PLUNGER WITH THE WATER DRAIN VALVE. N_MM_123228_3_AQM0_02_01
Page 8 of 8
Fuel Sampling For Analysis - Suction Procedure : Fuel Sampling For Analysis - Suction Procedure - Sheet 2