TECHNICAL DATA
CABLE GLAND TYPE : A2F
INGRESS PROTECTION : IP66, IP67, IP68, NEMA 4X

INSTALLATION INSTRUCTIONS
PROCESS CONTROL SYSTEM : ISO 9001
ISO/IEC 80079-34:2011
EXPLOSIVE ATMOSPHERES CLASSIFICATION
ATEX CERTIFICATION No : CML 18ATEX1321X, CML 18ATEX4313X

FOR A2F CABLE GLAND


ATEX CERTIFICATION CODE : ^II 2G Ex db IIC Gb, II 2G Ex eb IIC Gb, II 1D Ex ta IIIC Da IP66, 67, 68
: ^ II 3G Ex nR IIC Gc IP66, 67, 68
UKEX CERTIFICATION No : CML 21UKEX1245X, CML 21UKEX4246X
UKEX CERTIFICATION CODE : ^II 2G Ex db IIC Gb, II 2G Ex eb IIC Gb, II 1D Ex ta IIIC Da IP66, 67, 68
: ^ II 3G Ex nR IIC Gc IP66, 67, 68
IECEx CERTIFICATION No
IECEx CERTIFICATION CODE
: IECEx 18.0179X
: Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da, Ex nR IIC Gc IP66, IP67, IP68
CABLE GLAND FOR USE WITH UNARMOURED AND BRAIDED
CSA CERTIFICATION No
CSA CERTIFICATION CODE
: 1211841
: Ex d IIC, Ex e II, Ex nR II, Enclosure Type 4X
CABLES IN EXPLOSIVE ATMOSPHERES
INSTALLATION INSTRUCTIONS
1. Installation should only be performed by a competent person using the correct tools. Spanners should be used for tightening. Read all instructions before beginning installation.
2. The interface between a cable entry device and its associated enclosure / cable entry will require additional sealing to achieve ingress protection (IP) ratings higher than IP54. The minimum protection level is IP54
for explosive gas atmospheres and IP6X for explosive dust atmospheres. Parallel threads (and tapered threads when using a non-threaded entry) require a CMP sealing washer or integral O-ring face seal (where
available) to maintain IP66, 67 and 68 (when applicable). It is the installer’s responsibility to ensure the IP rating is maintained at the interface. INCORPORATING EU DECLARATION OF CONFORMITY TO DIRECTIVE 2014/34/EU AND UK
3.
Note: When fitted to a threaded entry, all tapered threads will automatically provide an ingress protection rating of IP66.
A CMP earth tag should be used when it is necessary to provide an earth bond connection. CMP earth tags have been independently tested to comply with Category B rating specified in IEC 62444 (there are no STATUTORY REQUIREMENTS SI 2016 No. 1107 (AS AMENDED)
ratings stated in IEC 60079-0). Ratings are shown in the associated table. CMP earth tags slip over the cable gland or accessory entry thread from inside/outside the enclosure and must be secured with a locknut
(if fitted internally).
4. Metric entry threads comply with ISO 965-1 and ISO 965-3 with a 6g tolerance as required by IEC 60079-1:2014. The CMP standard metric thread pitch is 1.5mm for threads up to M75, and 2.0mm from M90
and above. Special thread pitches between 0.7 – 2.0mm are available on all products on request. See certificate for details of other thread types. NPT threads are in accordance with ASME B1.20.1-2013 gauging
to Cl 3.2 for external threads. For details of other thread types refer to IECEx certificate.
5. Enclosures must be strong enough to support the cable and cable gland assembly. The enclosure surface finish must be smooth and flat to facilitate sealing with an O-ring or Entry Thread Sealing Washer for the
required IP rating.
6. Enclosure walls must be sufficiently strong enough to support the cable and cable gland assembly. Enclosure entries shall be perpendicular. Any draft angles from the casting/moulding process should have a
perpendicular flat spot machined to facilitate sealing with an O-ring or Entry Thread Sealing Washer.
7. CMP Products recommends that when using the cable gland with a through-hole, the hole must be circular, free of burrs and the diameter no larger than 0.7mm above the thread major diameter.
A suitable CMP Products locknut shall be used to secure the product. See CMP Products catalogue for locknut options.
8. Cable glands do not have any serviceable parts and are therefore not intended to be repaired.

SPECIFIC CONDITIONS OF USE


1. All cable gland types and sizes are only suitable for fixed installations. Cables must be effectively clamped to prevent pulling or twisting.
2. The entry item component may be supplied with an alternative nearest equivalent recognised thread type and size to the metric thread, whilst maintaining a tolerance of fit, equal to or better than, a medium
fit to ISO 965-1 & ISO 965-3. Intended for use within existing installations only, that incorporate female thread types that are no longer permitted by the current edition of EN/IEC 60079-1, but comply with the
requirements of EN 50018:2000 & IEC 60079-1:2001 Product selection table
3. When the cable glands are supplied with an entry thread that is one size up from the nominal gland size, designated with the letter ‘B’ after the gland size, e.g. 32B****, they shall not be used with any adaptor
device. Available Entry Threads Combined Ordering
(Alternate Metric Thread Lengths Available) Overall Cable Across Across
4. The cable glands shall only be used where the temperature, at the point of entry, is in the following ranges: Reference
Diameter Flats Corners Cable
a. EPDM (Black): -60°C +130°C Cable Gland Standard Option Protrusion (*Brass Metric)
Shroud Gland Weight
5. For Ex d applications, cable gland types CA2F, CA2F-RC, CA2F-FC, CA2F-HC and CA2F- FF are to be installed in associated Ex d equipment having a minimum wall thickness as follows: Size Length
Thread Length Thread Ordering (kg)
a. 10.5mm minimum for cable gland having entry thread sizes M16 x 1.5 to M75 x 1.5 Metric NPT NPT Min Max Max Max Size Type
(Metric) Length (NPT) Suffix
b. 12.5mm minimum for cable gland having entry thread sizes M90 x 2.0 to M115 x 2.0
6. Designed for appropriate Steel Tape Armour (STA), Steel Wire Armour (SWA), and appropriate braided cable. These cables must be extruded sealing (solid polymeric) completely surrounding the “core” (insulation 16S* M16 15.0 - - - 2.0 7.4 24.0 26.4 29.9 16S A2F 1RA PVC04 0.060
and conductor), allowing for no holes or ventilation through the inner jacket or along the cores. 16 M16 15.0 - - - 3.2 8.7 24.0 26.4 29.9 16 A2F 1RA PVC04 0.060
7. IEC Canadian Standards may have either tapered or non-tapered threads which comply with ISO Standards. 20S/16S* M20 15.0 1/2” 19.9 3/4” 2.0 7.4 24.0 26.4 26.0 20S16S A2F 1RA PVC04 0.070
8. According to CEC C22.1 -98, Section 18-106 Part 3, Tapered Threads shall have 5 fully engaged threads, and where non-tapered threads are used in Groups IIC there must be 8 fully engaged threads. 20S/16 M20 15.0 1/2” 19.9 3/4” 3.2 8.7 24.0 26.4 26.0 20S16 A2F 1RA PVC04 0.070
20S M20 15.0 1/2” 19.9 3/4” 6.1 11.7 24.0 26.4 26.0 20S A2F 1RA PVC04 0.060
ACCESSORIES 20 M20 15.0 1/2” 19.9 3/4” 6.5 14.0 27.0 29.7 27.7 20 A2F 1RA PVC05 0.070
The following accessories are available from CMP Products, as optional extras, to assist with fixing, sealing and earthing: 25 M25 15.0 3/4” 20.2 1” 11.1 20.0 36.0 39.6 35.5 25 A2F 1RA PVC09 0.130
Locknut, Earth Tag, Serrated Washer, Entry Thread (I.P.) Sealing Washer, Shroud 32 M32 15.0 1” 25.0 1 1/4” 17.0 26.3 41.0 45.1 35.1 32 A2F 1RA PVC10 0.150
40 M40 15.0 1 1/4” 25.6 1 1/2” 23.5 32.2 50.0 55.0 35.1 40 A2F 1RA PVC13 0.200
Short Circuit Ratings Symmetrical Fault Current
CMP Earth Tag Size 50S M50 15.0 1 1/2” 26.1 2” 31.0 38.2 55.0 60.5 33.0 50S A2F 1RA PVC15 0.260
(kA) for 1 second
50 M50 15.0 2” 26.9 2 1/2” 35.6 44.0 60.0 66.0 37.3 50 A2F 1RA PVC18 0.270
20 3.06
25 4.06 63S M63 15.0 2” 26.9 2 1/2” 41.5 49.9 70.5 77.6 33.5 63S A2F 1RA PVC21 0.430
32 5.40 63 M63 15.0 2 1/2” 39.9 3” 47.2 55.9 75.0 82.5 36.2 63 A2F 1RA PVC23 0.400
40 7.20 75S M75 15.0 2 1/2” 39.9 3” 54.0 61.9 84.0 92.4 34.1 75S A2F 1RA PVC24 0.520
50 10.40 75 M75 15.0 3” 41.5 3 1/2” 61.1 67.9 84.0 92.4 40.9 75 A2F 1RA PVC24 0.500
63 10.40 90 M90 24.0 3 1/2” 42.8 4” 66.6 79.9 108.0 118.8 60.3 90 A2F 1RA PVC31 1.600
75 10.40 100 M100 24.0 4” 44.0 4” 76.0 91.0 123.0 135.3 57.2 100 A2F 1RA LSF33 1.780
CMP Products Limited on its sole responsibility declares that the equipment referred to herein conforms to the requirements of the ATEX Directive 2014/34/EU and UK statutory 115 M115 24.0 4” 44.0 5” 86.0 97.9 133.4 146.7 67.3 115 A2F 1RA LSF34 2.670
requirements SI 2016 No. 1107 (as amended). This is shown in the following harmonised/designated standards; and/or the latest technical knowledge. 130 M130 24.0 5” 46.8 - 97.0 114.9 152.4 167.6 74.7 130 A2F 1RA LSF35 3.800
Dimensions are displayed in millimetres unless otherwise stated
EN IEC 60079-0:2018, EN 60079-1:2014, EN IEC 60079-7:2015 + A1:2018, EN IEC 60079-15:2019, IEC 60079-31:2022
Note: Standard Seal (Black) Temperature Range = -60°C to +130°C,
High Temperature Seal (Brown) Temperature Range = -60°C to +180°C for High Temperature Seal add ‘HT’ to ordering reference after Gland Type e.g. 20SA2FHT1RA.
*Only available with standard seal material and ATEX/IECEx/UKEX certification.
FI413
Malcolm Webber - Product Engineering Manager - (Authorised Person)
CMP Products Limited, Cramlington, NE23 1WH, UK Certificate Revision Date

EU Economic Operator: CMP Products Germany GmbH. Address: Lukasstraße 25a, 52070 Aachen UKEX 1 01/24
17th March 2020 IFS 24 04/24
Glasshouse Street • St. Peters • Newcastle upon Tyne • NE6 1BS

2776 Notified Body: CML B.V., Koopvaardijweg 32, 4906CV Oosterhout, The Netherlands Tel: +44 191 265 7411 • Fax: +44 1670 715 646
E-Mail: customerservices@cmp-products.com • Web: www.cmp-products.com
ATEX / IECEx 4 01/24

2503
CSA 2 01/17
Approved Body: Eurofins E&E CML Limited, Newport Business Park, New Port Road, Ellesmere Port, CH65 4LZ

www.cmp-products.com www.cmp-products.com
INSTALLATION INSTRUCTIONS FOR CMP CABLE GLAND TYPES A2F 4. Slacken the seal nut (3) to relax the seal (2).

CABLE GLAND COMPONENTS - It is not necessary to dismantle the cable gland any further than illustrated below
1. Entry Item 1 2 3
2. Seal
3. Seal Nut

PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING THE INSTALLATION


1. It is not necessary to dismantle the gland any further than illustrated below.

5. Pass the cable through the gland to the desired position, then tighten the seal nut using a spanner until resistance is felt (when the
seal contacts the cable). Tighten with a spanner one further turn.

2. Fit the gland into the equipment and fully tighten the entry item (1).

3. Determine the conductor length required to suit the installation and prepare the cable accordingly, removing part of the outer sheath
where required to reveal the insulated conductors.