Data Cable7860ENH

The document describes the specifications and features of the Part Number 7860ENH, a Category 6 Bonded-Pair ScTP Cable designed for indoor use with a maximum frequency of 250 MHz. It includes details on physical characteristics, electrical performance, mechanical properties, and compliance with various standards. The cable supports current and future applications like Gigabit Ethernet and is available in multiple color variants.

Uploaded by

saied mereb
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
18 views3 pages

Data Cable7860ENH

The document describes the specifications and features of the Part Number 7860ENH, a Category 6 Bonded-Pair ScTP Cable designed for indoor use with a maximum frequency of 250 MHz. It includes details on physical characteristics, electrical performance, mechanical properties, and compliance with various standards. The cable supports current and future applications like Gigabit Ethernet and is available in multiple color variants.

Uploaded by

saied mereb
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Part Number: 7860ENH

Category 6 Bonded-Pair ScTP Cable

Product Description
Cat. 6 (250MHz), 4-Pair, F/UTP Foil shielded, Premise Horizontal Cable, 23 AWG solid bare copper conductors, Polyethylene insulation, Beldfoil® shield,
AWG 26 solid tinned copper drainwire, LSZH jacket

Technical Specifications

Product Overview

Environmental Space: Indoor - Euroclass Dca

Horizontal and building backbone cable; Support current and future Category 6 and 5e applications, such as: 1000Base - T (Gigabit Ethernet), 100 Base - T,
Suitable Applications:
10 Base - T, FDDI, ATM

Physical Characteristics (Overall)

Conductor

Element AWG Stranding Material No. of Pairs

Individual pair 23 Solid BC - Bare Copper 4

Conductor Count: 8

Total Number of Pairs: 4

Conductor Size: 23 AWG

Insulation

Element Type Material Nominal Diameter

Individual pair Dielectric Polyethylene 1.35 mm

Color Chart

Number Color

Pair 1 White/Blue & Blue

Pair 2 White/Green & Green

Pair 3 White/Orange & Orange

Pair 4 White/Brown & Brown

Outer Shield Material

Type Material Coverage [%] Drainwire Material Drainwire AWG Drainwire Position

Tape Aluminum/Polyester 100 % Solid tinned copper 26 Over foil

Aluminum/Polyester

Note: Aluminum facing outside in contact with drain wire

Outer Jacket Material

Material Color Nominal Diameter Diameter +/- Tolerance

LSZH / FRNC Grey or Blue 7.3 mm 0.3 mm

Construction and Dimensions

Min Elongation at Breakof Conductors: 10 %

Min Elongation at Breakof Insulation: 100 %

Cabling

Filler

Cross Web of Polyolefin

Min Elongation at Breakof Jacket: 100 %


Min Tensile Strength of Jacket: 9 MPa

Electrical Characteristics

Conductor DCR

Max. Conductor DCR Max DCR Unbalanced Between Pairs [%] Max. DCR Unbalanced Within Pair [%]

95 Ohm/km 4% 2 Ohm

Capacitance

Max. Capacitance Unbalance Max. Mutual Capacitance

1,600 pF/m 56 pF/m

Shielding: F/UTP - Overall Foil

Impedance

Nominal Characteristic Impedance

100 Ohm

Delay

Max. Delay Skew Min. Velocity of Propagation

40 ns/100m 60 %

High Freq

Frequency Max. Insertion Loss Min. NEXT Min. PSNEXT Min. ACR Min. PSACR Min. ACRF Min. PSACRF Min. RL (Return Min. TCL Min. ELTCTL
[MHz] (Attenuation) [dB] [dB] [dB] [dB] (ELFEXT) [dB] (PSELFEXT) [dB] Loss) [dB] [dB] [dB]

1 MHz 2.1 dB/100m 75.3 dB 72.3 dB 73.2 dB 70.2 dB 70 dB 67 dB 20 dB 40 dB 35 dB

4 MHz 3.8 dB/100m 66.3 dB 63.3 dB 62.4 dB 59.4 dB 58 dB 55 dB 23 dB 34 dB 23 dB

10 MHz 6 dB/100m 60.3 dB 57.3 dB 54.3 dB 51.3 dB 50 dB 47 dB 25 dB 30 dB 15 dB

16 MHz 7.6 dB/100m 57.2 dB 54.2 dB 49.6 dB 46.6 dB 45.9 dB 42.9 dB 25 dB 28 dB 10.9 dB

20 MHz 8.5 dB/100m 55.8 dB 52.8 dB 47.3 dB 44.3 dB 44 dB 41 dB 25 dB 27 dB 9 dB

31.2 MHz 10.7 dB/100m 52.9 dB 49.9 dB 42.1 dB 39.1 dB 40.1 dB 37.1 dB 23.6 dB 25.1 dB 5.1 dB

62.5 MHz 15.5 dB/100m 48.4 dB 45.4 dB 32.9 dB 29.9 dB 34.1 dB 31.1 dB 21.5 dB 22 dB

100 MHz 19.9 dB/100m 45.3 dB 42.3 dB 25.4 dB 22.4 dB 30 dB 27 dB 20.1 dB 20 dB

155 MHz 25.3 dB/100m 42.4 dB 39.4 dB 17.1 dB 14.1 dB 26.2 dB 23.2 dB 18.8 dB 18.1 dB

200 MHz 29.1 dB/100m 40.8 dB 37.8 dB 11.6 dB 8.6 dB 24 dB 21 dB 18 dB 17 dB

250 MHz 33 dB/100m 39.3 dB 36.3 dB 6.3 dB 3.3 dB 22 dB 19 dB 17.3 dB 16 dB

High Freq Table Note: Limits below 4MHz are for information only.

Coupling Attenuation

Coupling Attenuation [dB]

Type II V dB

Coupling Attenuation Class: Type II

Transfer Impedance

Frequency [MHz] Description Transfer Impedance

1 Mhz Grade 2 Max.50 mOhm/m

10 Mhz Max. 100 mOhm/m

30 Mhz Max. 200 mOhm/m

100 Mhz Max. 1000 mOhm/m

Current

Max. Recommended Current [A]

1.5 A

Voltage

Voltage Rating [V]

72 V

Temperature Range

Installation Temp Range: 0°C To +50°C

Operating Temp Range: -30°C To +60°C

Mechanical Characteristics

Bulk Cable Weight: 50 kg/km


Max Recommended Pulling Tension: 80 N

Min Bend Radius During Installation: 58 mm

Min Bend Radius During Operation: 29 mm

Standards

ISO/IEC Compliance: ISO/IEC 11801 Ed. 2.2:2002/A2:2010/C1:2011

CPR Euroclass: Dca-s2,d1,a1

CENELEC Compliance: EN 50173-1 Ed. 3:2011

Data Category: Category 6

ANSI Compliance: ANSI/TIA/EIA 568-B.2-1 (2002)

Flammability, LS0H, Toxicity Testing

ISO/IEC Flammability: IEC 60332-1

Burning Load: 745 kJ/m

Amount of Halogen acc. to IEC 60754-1 & Zero


EN50267-1:

Part Number

Variants

Item # Color

7860ENH.03500 Black, RAL 9005

7860ENH.011000 Blue, RAL 5015

7860ENH.01500 Blue, RAL 5015

7860ENH.001000 Gray

7860ENH.002000 Gray

7860ENH.002100 Gray

7860ENH.00305 Gray

7860ENH.00500 Gray

7860ENH.00B100 Gray

7860ENH.02500 Purple

7860ENH.04500 Yellow

Patent: http://www.belden.com/p

History

Revision Number: 4

© 2018 Belden, Inc


All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and