Product: 3076ELS
Profibus PA, 1PR #18 Str TC, PO ins, OS, LSNH Jkt, 300V SWA
Product Description
Profibus PA, 1 Pair AWG 18 Tinned Copper - Stranded, Polyolefin (PO, PE, PP) insulation, Foil(s) or Copper Tape(s) shielding, LSZH / FRNC jacket , 300V
SWA
Technical Specifications
Product Overview
Profibus PA or Foundation FieldBus PA exposure to rodent, crush, or cut through force, harsh environment, outdoors, where multiple cable runs are required, data
Suitable Applications:
transmission applications such as Profibus DP or PA, Instrumentation and computer cable, etc. exposure to temperature extremes, humidity/moisture, dust, and oil.
Physical Characteristics (Overall)
Conductor
AWG Stranding Material
18 7x26 TC - Tinned Copper
Conductor Count: 2
Total Number of Pairs: 1
Insulation
Material Nominal Diameter Diameter +/- Tolerance Nominal Wall Thickness
PE - Polyethylene 2.55 mm 0.05 mm 0.67 mm
Color Chart
Number Color
Option .00 with blue inner- and outerjacket White & Black
Option .02 with yellow inner- and outerjacket White & Black
Option .03 with orange inner- and outerjacket White & Black
Option .05 with blue inner- and orange outer jacket White & Black
Option .07 with orange inner- and black outer jacket Orange & Blue
Inner Shield
Type Material Drainwire Material Drainwire AWG
Tape Bi-Laminate (Alum+Poly) TC - Tinned Copper AWG20/7
Inner Jacket
Material Nominal Diameter Nominal Wall Thickness
LSZH - Low Smoke Zero Halogen (Flame Retardant) 7.5 mm 1.15 mm
Outer Jacket
Material Nominal Diameter Nominal Wall Thickness
LSZH - Low Smoke Zero Halogen (Flame Retardant) 13 mm 1.85 mm
Construction and Dimensions
Armor
Type of Armor Material Thickness of Armoring Wires Coverage Percentage
Steel Wire Armoring Galvanized steel wire 0.9 mm Min. 95%
Electrical Characteristics
Conductor DCR
Max. Conductor DCR Max. Outer Shield DCR
20.5 Ohm/km 26 Ohm/km
Capacitance
Max. Capacitance Conductor to Conductor Max. Capacitance Conductor to Shield Max. Capacitance Unbalance
80 pF/m 155 pF/m 4 pF/m
Inductance
Nominal Inductance
0.62 uH/m
Impedance
Frequency [MHz] Nominal Characteristic Impedance Nominal Characteristic Tolerance
0.03125 MHz 100 Ohm 5 Ohm
Delay
Nominal Velocity of Propagation (VP) [%]
66%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation)
0.01 MHz 0.2 dB/100m
0.039 MHz 0.3 dB/100m
0.1 MHz 0.6 dB/100m
0.5 MHz 2.8 dB/100m
1 MHz 3.7 dB/100m
Voltage
Voltage Rating [V]
300 V
Temperature Range
Installation Temperature Range: -15°C To +80°C
Storage Temperature Range: -45°C To +80°C
Operating Temp Range (Flexible -15°C To +80°C
Install):
Operating Temp Range (Fixed -45°C To +80°C
Install):
Mechanical Characteristics
Oil Resistance: IEC 60811-404
Min. Bend Radius During Installation: 260 mm
Standards
ISO/IEC Compliance: IEC 61158-2
CPR Euroclass: Eca
CENELEC Compliance: EN 50290-2-27, EN 50288-7
Applicable Environmental and Other Programs
Environmental Space: Indoor/Outdoor - Euroclass Eca
Suitability
Suitability - Outdoor: Yes
Suitability - Sunlight Resistance: Yes
Flammability, LS0H, Toxicity Testing
IEC Flammability: IEC 60332-1-2, IEC 60332-3-24
IEC 60754-1 - Halogen Amount: Zero
IEC 60754-2 - Halogen Acid Gas 2.5 µS/mm
Amount - Max. Conductivity:
IEC 60754-2 - Halogen Acid Gas 4.3
Amount - Min. pH:
IEC 61034-2 - Smoke Density Min. 60%
Transmittance:
Related Part Numbers
Variants
Item # Color Put-Up Type Length EAN
3076ELS.07500 Black Reel 500 m 8719605180131
3076ELS.00500 Blue Reel 500 m 8719605005397
3076ELS.001000 Blue Reel 1,000 m 8719605005380
3076ELS.03320 Orange Reel 320 m 8719605005441
3076ELS.03500 Orange Reel 500 m 8719605005458
3076ELS.031000 Orange Reel 1,000 m 8719605005434
3076ELS.051000 Orange Reel 1,000 m 8719605005465
3076ELS.031150 Orange Reel 1,150 m 8719605179968
3076ELS.02500 Yellow Reel 500 m 8719605005427
3076ELS.021000 Yellow Reel 1,000 m 8719605005403
3076ELS.021100 Yellow Reel 1,100 m 8719605005410
History
Update and Revision: Revision Number: 0.229 Revision Date: 03-30-2023
© 2023 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and
regulations based on their individual usage of the product.