Belden 3084a

The 3084A DeviceBus® cable is designed for ODVA DeviceNet™ applications, featuring 2 pairs of 22+24AWG tinned copper conductors with PVC and foam PE insulation. It is suitable for harsh environments and industrial automation, supporting communication between devices like sensors and PLCs. The cable complies with various standards, including UL and NEC, and offers a maximum current rating of 4 Amps per conductor.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
24 views2 pages

Belden 3084a

The 3084A DeviceBus® cable is designed for ODVA DeviceNet™ applications, featuring 2 pairs of 22+24AWG tinned copper conductors with PVC and foam PE insulation. It is suitable for harsh environments and industrial automation, supporting communication between devices like sensors and PLCs. The cable complies with various standards, including UL and NEC, and offers a maximum current rating of 4 Amps per conductor.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Product: 3084A

DeviceBus®, 2 Pr #22+24 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt,
CMG, CL2

Product Description
DeviceBus® for ODVA DeviceNet™, 2 Pair 22+24AWG (19x34+19x36) Tinned Copper, PVC+Foam PE Insulation, Individual Beldfoil® & OA Tinned Copper
Braid(65%) Shield, PVC Outer Jacket, CMG, CL2

Technical Specifications
harsh environment, ODVA device-level communication, used with CIP (common Industrial Protocol) for control, configuration, and data collection between devices, such as sensors
Suitable Applications:
and actuators, and higher level devices such as PLC, and PC in industrial automation, bus topology, etc.

Conductor

Element Number of Element AWG Stranding Material

Power Pair(s) 1 22 19x34 TC - Tinned Copper

Data Pair(s) 1 24 TC - Tinned Copper

Insulation

Element Material Thickness [in.] Color Code

Power Pair(s) PVC - Polyvinyl Chloride 0.021 Red & Black

Data Pair(s) PE - Polyethylene (Foam) 0.026 Blue & White

Inner Shield Material

Element Shield Type Material Coverage

Power Pair(s) Tape Bi-Laminate (Alum+Poly) 100%

Data Pair(s) Tape Bi-Laminate (Alum+Poly) 100%

Outer Shield Material

Shield Type Material Coverage Drainwire Type

Braid Tinned Copper (TC) 65% 22 AWG (19x34) TC

Outer Jacket Material

Material Thickness Nom. Diameter

PVC - Polyvinyl Chloride 0.032 in 0.280 in

Cable Diameter 0.280 in


(Nominal):

Electricals

Element Nom. Conductor DCR Nom. Capacitance Cond-to-Cond Characteristic Impedence Max. Current

Power Pair(s) 17.5 Ohm/1000ft 4 Amps per Conductor at 25ºC (Power Pair)

Data Pair(s) 28.0 Ohm/1000ft 12 pF/ft 120 Ohm 4 Amps Per Conductor at 24 V (per NEC CL2) (Power Pair)

Nom Outer Shield DCR: 3.2 Ohm/1000ft

High Freq

Element Frequency [MHz] Max. Insertion Loss (Attenuation)

Data Pair(s) 0.125 MHz .95 dB/100ft

0.5 MHz 1.64 dB/100ft

1 MHz 2.3 dB/100ft

Voltage

UL Voltage Rating
300 V (CMG), 600 V (UL AWM 20201)

Temperature

UL Rating Operating

75°C -20°C to +60°C

Bend Radius

Stationary Min. Installation Min.

3.36 in 3.36 in

Max. Pull Tension: 65 lbs

Bulk Cable Weight: 155 lbs/1000ft

Environmental Suitability: Indoor, Sunlight Resistance, Oil Resistance

Flammability / Fire UL1685 FT4 Loading, FT4, 1202, IEC 60332-1-2


Resistance:

NEC / UL Compliance: Article 725, Article 800, CL2, CMG

AWM Compliance: 20201, I/II A

CEC / C(UL) CMG


Compliance:

CPR Euroclass: Eca

European Directive EU CE Mark, EU Directive 2015/863/EU, EU Directive 2011/65/EU (ROHS II), EU Directive 2012/19/EU (WEEE)
Compliance:

APAC Compliance: China RoHS II (GB/T 26572-2011)

Other Standard ODVA Class 2 Thin


Compliance(s):

Flex Life: +/- 90 Degree Flex Test, 2" Diameter, 2 lbs. tension: 2000 Cycles minimum. Meter marks on jacket to aid users in installation. ODVA DeviceNet is an Open DeviceNet
Notes:
Vendor Association, Inc. trademark.

Update and Revision: Revision Number: 0.388 Revision Date: 08-25-2020

© 2020 Belden, Inc


All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and
regulations based on their individual usage of the product.

You might also like