0% found this document useful (0 votes)
13 views16 pages

204 1b Communication Offshore 1

204 1b Communication Offshore 1

Uploaded by

sakda wongiam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views16 pages

204 1b Communication Offshore 1

204 1b Communication Offshore 1

Uploaded by

sakda wongiam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

Conducting Value

COMMUNICATION CABLES
FOR MARINE
AND OFFSHORE APPLICATIONS

204/1b
CORPORATE VIDEO

ISO 9001:2015
Certificate No. CS1-249

MANAGEMENT
SYSTEMS

Assessed to ISO 9001:2015


Cert/LPCB ref. 217

ISO 9001:2015
n. 9125.CAVL

ISO 14001:2015
n. 9191.CVCL
MARINE AND OFFSHORE
COMMUNICATION CABLES
Cavicel provides a wide range of Marine
and Offshore cables able to meet the highest
requirements of performance and safety.

Beyond the cables presented in this catalogue, Cavicel


offers customized solutions, including hybrid cables.

Be safe and choose Cavicel cables

Fiber Optic Cables

Fire Resistant Cables

Instrumentation and Control Cables

MADE IN ITALY
QFCI/QFCU
Multiloose Fire resistant
MLO-000-**-M1-A1-FR-QFCI/QFCU

Approved by: APPLICATIONS OPERATING TEMPERATURE

• Safety Systems, Critical Connections -40 °C / + 70 °C (operating)


and Fire Fighting Systems -40 °C / + 70 °C (storage)
• Outdoor installation in Off-shore, Oil & -10 °C / + 70 °C (installation)
Gas and Marine applications
• Data transmission and MINIMUM BENDING RADIUS
telecommunication systems
20 times overall diameter (dynamic)
10 times overall diameter (static)

CABLE CONSTRUCTION APPLICABLE STANDARDS

Fibres Materials Smoke density


Singlemode and multimode fibres, with loose technology IEC 60092-360 IEC 61034-2 EN 50268-2
coating. Optical fibre characteristics Cables for offshore installation
Structure IEC 60794-1-1, IEC 60794-1-2 NEK 606
The jelly filled tubes containing the fibres are individually
Fire resistant
wrapped with a mica tape and are cabled around a central steel
IEC 60331-25
or FRP (fibreglass reinforced plastic) element. A flame resistant
tape improves fire resistance. Fire retardant
Inner sheath IEC 60332-3-24
LSZH compound. Flame retardant
Armouring IEC 60332-1-2
Galvanized steel wire braid Acid gas emission
Outer sheath IEC 60754-1, EC 60754-2
QFCI type: LSZH - SHF1 compound
QFCU type: LSZH SHF2, SHF2 MUD resistant compound(1)

Fibre Tube Diameter Diameter Weight Tension load Crush


Type
(n° max) (mm) (mm) (kg/km) (N) (N/100mm)
MLO-000-**(n)-M1-A1-FR-QFCI/QFCU 4 2.5 13.5 230 1500 3000
MLO-000-**(n)-M1-A1-FR-QFCI/QFCU 8 2.5 13.5 230 1500 3000
MLO-000-**(n)-M1-A1-FR-QFCI/QFCU 12 2.5 13.5 230 1500 3000
MLO-000-**(n)-M1-A1-FR-QFCI/QFCU 24 2.5 13.5 230 1500 3000
MLO-000-**(n)-M1-A1-FR-QFCI/QFCU 48 2.5 13.5 230 1500 3000

approximate values
Tested for: Oil based drilling fluid , Calcio Bromide Brine, IRM 902 and IRM 903 oils
(1)

M A D E I N ITA LY

Cavicel, Conducting Value 4


AICI/AICU
MultiTight
MTI-000-**-M1-A1-AICI/AICU

Approved by: APPLICATIONS OPERATING TEMPERATURE

• Outdoor installation in Off-shore, Oil & -40 °C / + 70 °C (operating)


Gas and Marine applications -40 °C / + 70 °C (storage)
• Data transmission and -10 °C / + 70 °C (installation)
telecommunication systems
MINIMUM BENDING RADIUS

20 times overall diameter (dynamic)


10 times overall diameter (static)

CABLE CONSTRUCTION APPLICABLE STANDARDS

Fibres Materials
Singlemode and multimode fibres, with tight technology coating. IEC 60092-360
Structure Optical fibre characteristics
Thight fibers (each single fiber rinforced by PA at 850 micron), IEC 60794-1-1, IEC 60794-1-2
assembled around a central FRP with peripheral swellable
Fireretardant
aramide yarns.
IEC 60332-3-24
Inner sheath
Flame retardant
LSZH compound.
IEC 60332-1-2
Armouring
Galvanized steel wire braid Acid gas emission
IEC 60754-1, IEC 60754-2
Outer sheath
AICI type: LSZH SHF1 compound Smoke density
AICU type: LSZH SHF2 - MUD resistant compound(1) IEC 61034-2
Cables for offshore installation
NEK 606

Fibre Tube Diameter Diameter Weight Tension load Crush


Type
(n° max) (mm) (mm) (kg/km) (N) (N/100mm)
MTI-000-**-M1-A1-AICI/AICU 2 0.850 7.8 88 500 2000
MTI-000-**-M1-A1-AICI/AICU 4 0.850 8.0 98 600 2000
MTI-000-**-M1-A1-AICI/AICU 8 0.850 9.0 110 800 2000
MTI-000-**-M1-A1-AICI/AICU 12 0.850 10.0 130 1000 2000

approximate values
(1) Test for: Oil based drilling fluid , Calcio Bromide Brine, IRM 902 and IRM 903 oils

M A D E I N ITA LY

Cavicel, Conducting Value 5


AIOI/AIOU
MultiTight
MTI-000-**-M1-A1-AIOI/AIOU

Approved by: APPLICATIONS OPERATING TEMPERATURE

• Outdoor installation in Off-shore, Oil & -40 °C / +70 °C (operating)


Gas and Marine applications -40 °C / +70 °C (storage)
• Data transmission and -10 °C / +70 °C (installation)
telecommunication systems
MINIMUM BENDING RADIUS

20 times overall diameter (dynamic)


10 times overall diameter (static)

CABLE CONSTRUCTION APPLICABLE STANDARDS

Fibres Materials
Singlemode and multimode fibres, with tight technology coating. IEC 60092-360
Structure Optical fibre characteristics
Thight fibers (each single fiber rinforced by PA at 850 micron), IEC 60794-1-1, IEC 60794-1-2
assembled around a central FRP with peripheral swellable
Fireretardant
aramide yarns.
IEC 60332-3-24
Inner sheath
Flame retardant
LSZH compound.
IEC 60332-1-2
Armouring
Tinned copper wire braid Acid gas emission
IEC 60754-1
Outer sheath
AIOI type: LSZH SHF1 compound IEC 60754-2
AIOU type: LSZH SHF2, SHF2 MUD resistant compound(1) Smoke density
IEC 61034-2
Cables for offshore installation
NEK 606

Fibre Diameter Weight Tension load Crush


Type Tube Diameter (mm)
(n° max) (mm) (kg/km) (N) (N/100mm)
MTI-000-**-M1-A1-AICI/AICU 2 0.850 7.8 88 500 2000
MTI-000-**-M1-A1-AICI/AICU 4 0.850 8.0 98 600 2000
MTI-000-**-M1-A1-AICI/AICU 8 0.850 9.0 110 800 2000
MTI-000-**-M1-A1-AICI/AICU 12 0.850 10.2 145 1000 2000
approximate values
(1)
Tested for: Oil based drilling fluid , Calcio Bromide Brine, IRM 902 and IRM 903 oils

MA D E I N ITA LY

Cavicel, Conducting Value 6


SLO-FR
Single tube fire resistant cable
SLO-000-**-M1-A1-WB-FR

Approved by: APPLICATIONS OPERATING TEMPERATURE

• Safety Systems, Critical Connections -40 °C / + 70 °C (operating)


and Fire Fighting Systems -40 °C / + 70 °C (storage)
• Outdoor installation in Off-shore, Oil & -10 °C / + 70 °C (installation)
Gas and Marine applications
• Data transmission and MINIMUM BENDING RADIUS
telecommunication systems
20 times overall diameter (dynamic)
10 times overall diameter (static)

CABLE CONSTRUCTION APPLICABLE STANDARDS

Fibres Materials Smoke density


Singlemode and multimode fibres, with loose technology IEC 60092-360 IEC 61034-2 EN 50268-2
coating. Optical fibre characteristics Cables for offshore installation
Structure IEC 60794-1-1, IEC 60794-1-2 NEK 606
The jelly filled tube containing up to 24 fibres wrapped with a
Fire resistant
mica tape. Overall glass yarns and glass tape to improve the fire
IEC 60331-25
and WB performance
Fire retardant
Inner sheath
LSZH compound. IEC 60332-3-22

Armouring Flame retardant


Galvanized steel wire braid IEC 60332-1-2
Outer sheath Acid gas emission
Type: LSZH - SHF1 compound IEC 60754-1, EC 60754-2

Fibre Tube Diameter Diameter Weight Tension load Crush


Type
(n° max) (mm) (mm) (kg/km) (N) (N/100mm)
SLO-000-**(n)-M1-A1-FR 4 2.7 9.6 120 1500 3000
SLO-000-**(n)-M1-A1-FR 8 2.7 9.6 120 1500 3000
SLO-000-**(n)-M1-A1-FR 12 2.7 9.6 120 1500 3000
SLO-000-**(n)-M1-A1-FR 24 2.7 9.6 120 1500 3000

approximate values

M A D E I N ITA LY

Cavicel, Conducting Value 7


LAN 7
S/FTP LSZH 4x2xAWG23/1 Cat.7 (up to 600 MHz)

APPLICATIONS OPERATING TEMPERATURE MINIMUM BENDING RADIUS

• Indoor/Outdoor installation in -20°C / +70°C (operating) 10 times the outer diameter (static)
Off-shore, Oil & Gas and Marine -20°C / +70°C (storage)
applications -10°C / +60°C (installation)
• Data transmission and
telecommunication systems
• Structured cabling for Ethernet
networks.

CABLE CONSTRUCTION PAIRS COLOUR CODE ELECTRICAL CHARACTERISTICS


Conductors 1st pair: Max DC conductor resistance
Plain annealed copper wire, AWG23/1 2nd pair: 73 Ω/km
3rd pair:
Insulation 4th pair:
Max operating voltage
Foam Polyolefin 125 Vac
Twisting/Individual screen APPLICABLE STANDARDS Min insulation resistance
The insulated cores shall be twisted in 5000 MΩ x km
pairs and wrapped with Al/Pet tape.
Standard reference Capacitance @800 Hz
Cabling IEC 61156-5; EN 50288-5-1; 43 pF/m
The pairs are cabled together EN 50289-4-16; ISO/IEC 11801;
Characteristic Impedance
NEK 606
Overall screen 100 Ω
Tinned copper braid. Flame retardant
Velocity of propagation
IEC 60332-1-2
Outer sheath >70%
LSZH thermoplastic material Fire retardant
Loop resistance
(SHF1 - SHF2 - SHF2 MUD resistant IEC 60332-3-22
146 Ω/km
compound (1)) Acid gas emission:
Nom. Outer diameter BS EN 60754-1, BS EN 60754-2
9.00 mm Smoke density
BS EN 61034-2

Outer Diameter Weight


Type N° Pairs Insulation Diameter (mm)
(mm) (kg/km)

CAT. 7 S/FTP LAN -SHF1 4 1.35 9.0 90


CAT. 7 S/FTP LAN -SHF2 4 1.35 9.0 90
CAT. 7 S/FTP LAN -SHF2 MUD 4 1.35 9.0 90

approximate values
Tested for: Oil based drilling fluid , Calcio Bromide Brine, IRM 902 and IRM 903 oils
(1)

M A D E I N ITA LY

Cavicel, Conducting Value 8


LAN 7 - Flexible
S/FTP LSZH 4x2xAWG23/7 Cat.7 (up to 600 MHz)

Approved by: APPLICATIONS OPERATING TEMPERATURE

• Indoor/Outdoor installation in -20°C / +70°C (operating)


Off-shore, Oil & Gas and Marine -20°C / +70°C (storage)
applications -5°C / +50°C (installation)
• Data transmission and
telecommunication systems MINIMUM BENDING RADIUS
• Structured cabling for Ethernet
networks. 12 times the outer diameter (static)

CABLE CONSTRUCTION PAIRS COLOUR CODE ELECTRICAL CHARACTERISTICS


Conductors 1st pair: Max DC conductor resistance
Plain annealed copper wire, AWG23/7 2nd pair: 73 Ω/km
3rd pair:
Insulation 4th pair:
Max operating voltage
Foam Polyolefin 125 Vac
Twisting/Individual screen APPLICABLE STANDARDS Min insulation resistance
The insulated cores shall be twisted in 5000 MΩ x km
pairs and wrapped with Al/Pet tape.
Standard reference Capacitance @800 Hz
Cabling IEC 61156-5; EN 50288-5-1; 43 pF/m
The pairs are cabled together EN 50289-4-16; ISO/IEC 11801; Characteristic Impedance
NEK 606; 100 Ω
Overall screen
Tinned copper braid. Flame retardant Velocity of propagation
IEC 60332-1-2 >70%
Outer sheath
LSZH thermoplastic material Fire retardant
(SHF1 - SHF2 - SHF2 MUD resistant IEC 60332-3-24
compound(1)) Acid gas emission:
Nom. Outer diameter BS EN 60754-1, BS EN 60754-2
9.00 mm Smoke density
BS EN 61034-2

Outer Diameter Weight


Type N° Pairs Insulation Diameter (mm)
(mm) (kg/km)

CAT. 7 S/FTP LAN -SHF1 4 1.55 9.0 100


CAT. 7 S/FTP LAN -SHF2 4 1.55 9.0 100
CAT. 7 S/FTP LAN -SHF2 MUD 4 1.55 9.0 100

approximate values
Tested for: Oil based drilling fluid , Calcio Bromide Brine, IRM 902 and IRM 903 oils
(1)

MA D E I N ITA LY

Cavicel, Conducting Value 9


LAN 7 A
S/FTP LSZH 4x2xAWG23/1 Cat.7A (up to 1000 MHz)

APPLICATIONS OPERATING TEMPERATURE MINIMUM BENDING RADIUS

• Indoor/Outdoor installation in -20°C / +70°C (operating) 10 times the outer diameter (static)
Off-shore, Oil & Gas and Marine -20°C / +70°C (storage)
applications -10°C / +60°C (installation)
• Data transmission and
telecommunication systems
• Structured cabling for Ethernet
networks.

CABLE CONSTRUCTION PAIRS COLOUR CODE ELECTRICAL CHARACTERISTICS


Conductors 1st pair: Max DC conductor resistance
Plain annealed copper wire, AWG23/1 2nd pair: 73 Ω/km
3rd pair:
Insulation 4th pair:
Max operating voltage
Foam Polyolefin 125 Vac
Twisting/Individual screen APPLICABLE STANDARDS Min insulation resistance
The insulated cores shall be twisted in 5000 MΩ x km
pairs and wrapped with Al/Pet tape.
Standard reference Capacitance @800 Hz
Cabling IEC 61156-5; EN 50288-5-1; 43 pF/m
The pairs are cabled together EN 50289-4-16; ISO/IEC 11801;
Characteristic Impedance
NEK 606;
Overall screen 100 Ω
Tinned copper braid Flame retardant
Velocity of propagation
IEC 60332-1-2
Outer sheath >70%
LSZH thermoplastic material Fire retardant
Loop resistance
(SHF1 - SHF2 - SHF2 MUD resistant IEC 60332-3-22
146 Ω/km
compound(1)) Acid gas emission:
Nom. Outer diameter BS EN 60754-1, BS EN 60754-2
9.00 mm Smoke density
BS EN 61034-2

Outer Diameter Weight


Type N° Pairs Insulation Diameter (mm)
(mm) (kg/km)

CAT. 7 S/FTP LAN -SHF1 4 1.35 9.0 90


CAT. 7 S/FTP LAN -SHF2 4 1.35 9.0 90
CAT. 7 S/FTP LAN -SHF2 MUD 4 1.35 9.0 90

approximate values
Tested for: Oil based drilling fluid , Calcio Bromide Brine, IRM 902 and IRM 903 oils
(1)

M A D E I N ITA LY

Cavicel, Conducting Value 10


LAN 7 A - Flexible
S/FTP LSZH 4x2xAWG23/7 Cat.7A (up to 1000 MHz)

Approved by: APPLICATIONS OPERATING TEMPERATURE

• Indoor/Outdoor installation in -20°C / +70°C (operating)


Off-shore, Oil & Gas and Marine -20°C / +70°C (storage)
applications -5°C / +50°C (installation)
• Data transmission and
telecommunication systems MINIMUM BENDING RADIUS
• Structured cabling for Ethernet
networks. 12 times the outer diameter (static)

CABLE CONSTRUCTION PAIRS COLOUR CODE ELECTRICAL CHARACTERISTICS


Conductors 1st pair: Max DC conductor resistance
Plain annealed copper wire, AWG23/7 2nd pair: 73 Ω/km
3rd pair:
Insulation 4th pair:
Max operating voltage
Foam Polyolefin 125 Vac
Twisting/Individual screen APPLICABLE STANDARDS Min insulation resistance
The insulated cores shall be twisted in 5000 MΩ x km
pairs and wrapped with Al/Pet tape.
Standard reference Capacitance @800 Hz
Cabling IEC 61156-5; EN 50288-5-1; 43 pF/m
The pairs are cabled together EN 50289-4-16; ISO/IEC 11801;
Characteristic Impedance
NEK 606;
Overall screen 100 Ω
Tinned copper braid. Flame retardant
Velocity of propagation
IEC 60332-1-2
Outer sheath >70%
LSZH thermoplastic material Fire retardant
(SHF1 - SHF2 - SHF2 MUD resistant IEC 60332-3-24
compound(1)) Acid gas emission:
Nom. Outer diameter BS EN 60754-1, BS EN 60754-2
9.00 mm Smoke density
BS EN 61034-2

Outer Diameter Weight


Type N° Pairs Insulation Diameter (mm)
(mm) (kg/km)

CAT. 7 S/FTP LAN -SHF1 4 1.55 9.0 100


CAT. 7 S/FTP LAN -SHF2 4 1.55 9.0 100
CAT. 7 S/FTP LAN -SHF2 MUD 4 1.55 9.0 100

approximate values
Tested for: Oil based drilling fluid , Calcio Bromide Brine, IRM 902 and IRM 903 oils
(1)

M A D E I N ITA LY

Cavicel, Conducting Value 11


LAN 7 - ARMOURED
S/FTP LSZH 4x2xAWG23/1 Cat.7 (up to 600 MHz)

Approved by: APPLICATIONS OPERATING TEMPERATURE

• Indoor/Outdoor installation in -20°C / +70°C (operating)


Off-shore, Oil & Gas and Marine -20°C / +70°C (storage)
applications -5°C / +50°C (installation)
• Data transmission and
telecommunication systems MINIMUM BENDING RADIUS
• Structured cabling for Ethernet
networks. 20 times the outer diameter (static)

CABLE CONSTRUCTION PAIRS COLOUR CODE ELECTRICAL CHARACTERISTICS


Conductors 1st pair: Max DC conductor resistance
Plain annealed copper wire, AWG23/1 2nd pair: 73 Ω/km
3rd pair:
Insulation 4th pair:
Max operating voltage
Foam Polyolefin 125 Vac
Twisting/Individual screen APPLICABLE STANDARDS Min insulation resistance
The insulated cores shall be twisted in 5000 MΩ x km
pairs and wrapped with Al/Pet tape. Standard reference Capacitance @800 Hz
Cabling IEC 61156-5; EN 50288-5-1; 43 pF/m
The pairs are cabled together EN 50289-4-16; ISO/IEC 11801;
NEK 606; Characteristic Impedance
Overall screen 100 Ω
Tinned copper braid Flame retardant
IEC 60332-1-2 Velocity of propagation
Inner sheath >70%
LSZH thermoplastic material Fire retardant
IEC 60332-3-22 Loop resistance
Armour 146 Ω/km
Galvanized steel wire braid Acid gas emission:
BS EN 60754-1, BS EN 60754-2
Outer sheath
LSZH thermoplastic material Smoke density
(SHF1 - SHF2 - SHF2 MUD resistant BS EN 61034-2
compound (1))
Nom. Outer diameter
12.6 mm

Insulation Diameter Outer Diameter Outer Diameter Weight


Type N° Pairs
(mm) (mm) (mm) (kg/km)

CAT. 7 S/FTP LAN -SHF1 4 1.35 9.0 12.6 200


CAT. 7 S/FTP LAN -SHF2 4 1.35 9.0 12.6 200
CAT. 7 S/FTP LAN -SHF2 MUD - GSWB 4 1.35 9.0 12.6 200

approximate values
(1)
Tested for: Oil based drilling fluid , Calcio Bromide Brine, IRM 902 and IRM 903 oils

M A D E I N ITA LY

Cavicel, Conducting Value 12


LAN 7A - ARMOURED
S/FTP LSZH 4x2xAWG23/1 Cat.7A (up to 1000 MHz)

Approved by: APPLICATIONS OPERATING TEMPERATURE

• Indoor/Outdoor installation in -20°C / +70°C (operating)


Off-shore, Oil & Gas and Marine -20°C / +70°C (storage)
applications -5°C / +50°C (installation)
• Data transmission and
telecommunication systems MINIMUM BENDING RADIUS
• Structured cabling for Ethernet
networks. 20 times the outer diameter (static)

CABLE CONSTRUCTION PAIRS COLOUR CODE ELECTRICAL CHARACTERISTICS


Conductors 1st pair: Max DC conductor resistance
Plain annealed copper wire, AWG23/1 2nd pair: 73 Ω/km
3rd pair:
Insulation 4th pair:
Max operating voltage
Foam Polyolefin 125 Vac
Twisting/Individual screen APPLICABLE STANDARDS Min insulation resistance
The insulated cores shall be twisted in 5000 MΩ x km
pairs and wrapped with Al/Pet tape. Standard reference Capacitance @800 Hz
Cabling IEC 61156-5; EN 50288-5-1; 43 pF/m
The pairs are cabled together EN 50289-4-16; ISO/IEC 11801;
NEK 606; Characteristic Impedance
Overall screen 100 Ω
Tinned copper braid Flame retardant
IEC 60332-1-2 Velocity of propagation
Inner sheath >70%
LSZH thermoplastic material Fire retardant
IEC 60332-3-22 Loop resistance
Armour 146 Ω/km
Galvanized steel wire braid Acid gas emission:
BS EN 60754-1, BS EN 60754-2
Outer sheath
LSZH thermoplastic material Smoke density
(SHF1 - SHF2 - SHF2 MUD resistant BS EN 61034-2
compound (1))
Nom. Outer diameter
12.6 mm

Insulation Diameter Outer Diameter Outer Diameter Weight


Type N° Pairs
(mm) (mm) (mm) (kg/km)

CAT. 7 S/FTP LAN -SHF1 4 1.35 9.0 12.6 200


CAT. 7 S/FTP LAN -SHF2 4 1.35 9.0 12.6 200
CAT. 7 S/FTP LAN -SHF2 MUD - GSWB 4 1.35 9.0 12.6 200

approximate values
(1)
Tested for: Oil based drilling fluid , Calcio Bromide Brine, IRM 902 and IRM 903 oils

MA D E I N ITA LY

Cavicel, Conducting Value 13


QUALITY IS OUR
BUSINESS
Conducting Value
Conducting Value

CAVICEL SpA
Via Caduti del Lavoro, 18/A
20096 Pioltello (Milano)
Italy
ph. +39 - 02 - 921.605.21
fax +39 - 02 - 921.607.53
e-mail: cavicel@cavicel.com

DUBAI BRANCH OFFICE


Fortune Executive Tower
Office 406 - Plot No. T1
Jumeirah Lakes Towers
Dubai - UAE - PO Box 634377
ph. +971 4.4581199
fax +971 4.4581144
e-mail: middleeast@cavicel.com

HONG KONG OFFICE


12/F, THE GRID
133 Wai Yip Street, Kwun Tong
Hong Kong
ph: +852 9472 3067
e-mail: apac@cavicel.com

www.cavicel.com

MADE IN ITALY

Cavicel firmly believes in the importance of the quality of its products and it undertakes itself to produce them using clean technologies for the respect and the protection of the environment.
_
All information contained in this brochure is believed to be accurate. Specifications can change at any time, according to technical developments and market changes.
All rights reserved. No part of this document may be reproduced in any form or by any means, without the prior written permission from Cavicel SpA.

You might also like