Conducting Value
COMMUNICATION CABLES
                 FOR MARINE
         AND OFFSHORE APPLICATIONS
204/1b
    CORPORATE VIDEO
     ISO 9001:2015
 Certificate No. CS1-249
                 MANAGEMENT
                   SYSTEMS
Assessed to ISO 9001:2015
    Cert/LPCB ref. 217
     ISO 9001:2015
      n. 9125.CAVL
     ISO 14001:2015
       n. 9191.CVCL
MARINE AND OFFSHORE
COMMUNICATION CABLES
Cavicel provides a wide range of Marine
and Offshore cables able to meet the highest
requirements of performance and safety.
Beyond the cables presented in this catalogue, Cavicel
offers customized solutions, including hybrid cables.
Be safe and choose Cavicel cables
                        Fiber Optic Cables
                        Fire Resistant Cables
                        Instrumentation and Control Cables
                          MADE IN ITALY
QFCI/QFCU
Multiloose Fire resistant
MLO-000-**-M1-A1-FR-QFCI/QFCU
Approved by:                                                APPLICATIONS                                    OPERATING TEMPERATURE
                                                            • Safety Systems, Critical Connections          -40 °C / + 70 °C (operating)
                                                              and Fire Fighting Systems                     -40 °C / + 70 °C (storage)
                                                            • Outdoor installation in Off-shore, Oil &      -10 °C / + 70 °C (installation)
                                                              Gas and Marine applications
                                                            • Data transmission and                         MINIMUM BENDING RADIUS
                                                              telecommunication systems
                                                                                                            20 times overall diameter (dynamic)
                                                                                                            10 times overall diameter (static)
CABLE CONSTRUCTION                                                                   APPLICABLE STANDARDS
Fibres                                                                               Materials                          Smoke density
Singlemode and multimode fibres, with loose technology                               IEC 60092-360                      IEC 61034-2 EN 50268-2
coating.                                                                             Optical fibre characteristics      Cables for offshore installation
Structure                                                                            IEC 60794-1-1, IEC 60794-1-2       NEK 606
The jelly filled tubes containing the fibres are individually
                                                                                     Fire resistant
wrapped with a mica tape and are cabled around a central steel
                                                                                     IEC 60331-25
or FRP (fibreglass reinforced plastic) element. A flame resistant
tape improves fire resistance.                                                       Fire retardant
Inner sheath                                                                         IEC 60332-3-24
LSZH compound.                                                                       Flame retardant
Armouring                                                                            IEC 60332-1-2
Galvanized steel wire braid                                                          Acid gas emission
Outer sheath                                                                         IEC 60754-1, EC 60754-2
QFCI type: LSZH - SHF1 compound
QFCU type: LSZH SHF2, SHF2 MUD resistant compound(1)
                                                   Fibre             Tube Diameter       Diameter        Weight           Tension load          Crush
                     Type
                                                 (n° max)                (mm)              (mm)          (kg/km)              (N)             (N/100mm)
MLO-000-**(n)-M1-A1-FR-QFCI/QFCU                    4                    2.5              13.5            230               1500               3000
MLO-000-**(n)-M1-A1-FR-QFCI/QFCU                    8                    2.5              13.5            230               1500               3000
MLO-000-**(n)-M1-A1-FR-QFCI/QFCU                   12                    2.5              13.5            230               1500               3000
MLO-000-**(n)-M1-A1-FR-QFCI/QFCU                   24                    2.5              13.5            230               1500               3000
MLO-000-**(n)-M1-A1-FR-QFCI/QFCU                   48                    2.5              13.5            230               1500               3000
approximate values
 Tested for: Oil based drilling fluid , Calcio Bromide Brine, IRM 902 and IRM 903 oils
(1)
M A D E I N ITA LY
Cavicel, Conducting Value                                                                                                                                 4
AICI/AICU
MultiTight
MTI-000-**-M1-A1-AICI/AICU
Approved by:                                                 APPLICATIONS                                          OPERATING TEMPERATURE
                                                             • Outdoor installation in Off-shore, Oil &            -40 °C / + 70 °C (operating)
                                                               Gas and Marine applications                         -40 °C / + 70 °C (storage)
                                                             • Data transmission and                               -10 °C / + 70 °C (installation)
                                                               telecommunication systems
                                                                                                                   MINIMUM BENDING RADIUS
                                                                                                                   20 times overall diameter (dynamic)
                                                                                                                   10 times overall diameter (static)
CABLE CONSTRUCTION                                                                        APPLICABLE STANDARDS
Fibres                                                                                    Materials
Singlemode and multimode fibres, with tight technology coating.                           IEC 60092-360
Structure                                                                                 Optical fibre characteristics
Thight fibers (each single fiber rinforced by PA at 850 micron),                          IEC 60794-1-1, IEC 60794-1-2
assembled around a central FRP with peripheral swellable
                                                                                          Fireretardant
aramide yarns.
                                                                                          IEC 60332-3-24
Inner sheath
                                                                                          Flame retardant
LSZH compound.
                                                                                          IEC 60332-1-2
Armouring
Galvanized steel wire braid                                                               Acid gas emission
                                                                                          IEC 60754-1, IEC 60754-2
Outer sheath
AICI type: LSZH SHF1 compound                                                             Smoke density
AICU type: LSZH SHF2 - MUD resistant compound(1)                                          IEC 61034-2
                                                                                          Cables for offshore installation
                                                                                          NEK 606
                                                    Fibre            Tube Diameter           Diameter          Weight           Tension load           Crush
                     Type
                                                  (n° max)               (mm)                  (mm)            (kg/km)              (N)              (N/100mm)
MTI-000-**-M1-A1-AICI/AICU                           2                  0.850                  7.8               88                500                2000
MTI-000-**-M1-A1-AICI/AICU                           4                  0.850                  8.0               98                600                2000
MTI-000-**-M1-A1-AICI/AICU                           8                  0.850                  9.0              110                800                2000
MTI-000-**-M1-A1-AICI/AICU                           12                 0.850                 10.0              130               1000                2000
approximate values
(1) Test for: Oil based drilling fluid , Calcio Bromide Brine, IRM 902 and IRM 903 oils
M A D E I N ITA LY
Cavicel, Conducting Value                                                                                                                                        5
AIOI/AIOU
MultiTight
MTI-000-**-M1-A1-AIOI/AIOU
Approved by:                                                 APPLICATIONS                                              OPERATING TEMPERATURE
                                                             • Outdoor installation in Off-shore, Oil &                -40 °C / +70 °C (operating)
                                                               Gas and Marine applications                             -40 °C / +70 °C (storage)
                                                             • Data transmission and                                   -10 °C / +70 °C (installation)
                                                               telecommunication systems
                                                                                                                       MINIMUM BENDING RADIUS
                                                                                                                       20 times overall diameter (dynamic)
                                                                                                                       10 times overall diameter (static)
CABLE CONSTRUCTION                                                                        APPLICABLE STANDARDS
Fibres                                                                                    Materials
Singlemode and multimode fibres, with tight technology coating.                           IEC 60092-360
Structure                                                                                 Optical fibre characteristics
Thight fibers (each single fiber rinforced by PA at 850 micron),                          IEC 60794-1-1, IEC 60794-1-2
assembled around a central FRP with peripheral swellable
                                                                                          Fireretardant
aramide yarns.
                                                                                          IEC 60332-3-24
Inner sheath
                                                                                          Flame retardant
LSZH compound.
                                                                                          IEC 60332-1-2
Armouring
Tinned copper wire braid                                                                  Acid gas emission
                                                                                          IEC 60754-1
Outer sheath
AIOI type: LSZH SHF1 compound                                                             IEC 60754-2
AIOU type: LSZH SHF2, SHF2 MUD resistant compound(1)                                      Smoke density
                                                                                          IEC 61034-2
                                                                                          Cables for offshore installation
                                                                                          NEK 606
                                                 Fibre                                    Diameter           Weight               Tension load            Crush
                   Type                                          Tube Diameter (mm)
                                               (n° max)                                     (mm)             (kg/km)                  (N)               (N/100mm)
 MTI-000-**-M1-A1-AICI/AICU                       2                   0.850                   7.8             88                     500                 2000
 MTI-000-**-M1-A1-AICI/AICU                       4                   0.850                   8.0             98                     600                 2000
 MTI-000-**-M1-A1-AICI/AICU                       8                   0.850                   9.0             110                    800                 2000
 MTI-000-**-M1-A1-AICI/AICU                      12                   0.850                   10.2            145                   1000                 2000
approximate values
(1)
      Tested for: Oil based drilling fluid , Calcio Bromide Brine, IRM 902 and IRM 903 oils
MA D E I N ITA LY
Cavicel, Conducting Value                                                                                                                                           6
SLO-FR
Single tube fire resistant cable
SLO-000-**-M1-A1-WB-FR
Approved by:                                       APPLICATIONS                                    OPERATING TEMPERATURE
                                                   • Safety Systems, Critical Connections          -40 °C / + 70 °C (operating)
                                                     and Fire Fighting Systems                     -40 °C / + 70 °C (storage)
                                                   • Outdoor installation in Off-shore, Oil &      -10 °C / + 70 °C (installation)
                                                     Gas and Marine applications
                                                   • Data transmission and                         MINIMUM BENDING RADIUS
                                                     telecommunication systems
                                                                                                   20 times overall diameter (dynamic)
                                                                                                   10 times overall diameter (static)
CABLE CONSTRUCTION                                                          APPLICABLE STANDARDS
Fibres                                                                      Materials                          Smoke density
Singlemode and multimode fibres, with loose technology                      IEC 60092-360                      IEC 61034-2 EN 50268-2
coating.                                                                    Optical fibre characteristics      Cables for offshore installation
Structure                                                                   IEC 60794-1-1, IEC 60794-1-2       NEK 606
The jelly filled tube containing up to 24 fibres wrapped with a
                                                                            Fire resistant
mica tape. Overall glass yarns and glass tape to improve the fire
                                                                            IEC 60331-25
and WB performance
                                                                            Fire retardant
Inner sheath
LSZH compound.                                                              IEC 60332-3-22
Armouring                                                                   Flame retardant
Galvanized steel wire braid                                                 IEC 60332-1-2
Outer sheath                                                                Acid gas emission
Type: LSZH - SHF1 compound                                                  IEC 60754-1, EC 60754-2
                                          Fibre             Tube Diameter      Diameter         Weight           Tension load          Crush
                     Type
                                        (n° max)                (mm)             (mm)           (kg/km)              (N)             (N/100mm)
SLO-000-**(n)-M1-A1-FR                     4                    2.7              9.6             120               1500               3000
SLO-000-**(n)-M1-A1-FR                     8                    2.7              9.6             120               1500               3000
SLO-000-**(n)-M1-A1-FR                    12                    2.7              9.6             120               1500               3000
SLO-000-**(n)-M1-A1-FR                    24                    2.7              9.6             120               1500               3000
approximate values
M A D E I N ITA LY
Cavicel, Conducting Value                                                                                                                        7
LAN 7
S/FTP LSZH 4x2xAWG23/1 Cat.7 (up to 600 MHz)
APPLICATIONS                                             OPERATING TEMPERATURE                                 MINIMUM BENDING RADIUS
• Indoor/Outdoor installation in                         -20°C / +70°C (operating)                             10 times the outer diameter (static)
  Off-shore, Oil & Gas and Marine                        -20°C / +70°C (storage)
  applications                                           -10°C / +60°C (installation)
• Data transmission and
  telecommunication systems
• Structured cabling for Ethernet
  networks.
CABLE CONSTRUCTION                                       PAIRS COLOUR CODE                                     ELECTRICAL CHARACTERISTICS
Conductors                                               1st pair:                                             Max DC conductor resistance
Plain annealed copper wire, AWG23/1                      2nd pair:                                             73 Ω/km
                                                         3rd pair:
Insulation                                               4th pair:
                                                                                                               Max operating voltage
Foam Polyolefin                                                                                                125 Vac
Twisting/Individual screen                               APPLICABLE STANDARDS                                  Min insulation resistance
The insulated cores shall be twisted in                                                                        5000 MΩ x km
pairs and wrapped with Al/Pet tape.
                                                         Standard reference                                    Capacitance @800 Hz
Cabling                                                  IEC 61156-5; EN 50288-5-1;                            43 pF/m
The pairs are cabled together                            EN 50289-4-16; ISO/IEC 11801;
                                                                                                               Characteristic Impedance
                                                         NEK 606
Overall screen                                                                                                 100 Ω
Tinned copper braid.                                     Flame retardant
                                                                                                               Velocity of propagation
                                                         IEC 60332-1-2
Outer sheath                                                                                                   >70%
LSZH thermoplastic material                              Fire retardant
                                                                                                               Loop resistance
(SHF1 - SHF2 - SHF2 MUD resistant                        IEC 60332-3-22
                                                                                                               146 Ω/km
compound (1))                                            Acid gas emission:
Nom. Outer diameter                                      BS EN 60754-1, BS EN 60754-2
9.00 mm                                                  Smoke density
                                                         BS EN 61034-2
                                                                                                                 Outer Diameter            Weight
                       Type                                 N° Pairs                Insulation Diameter (mm)
                                                                                                                      (mm)                 (kg/km)
 CAT. 7 S/FTP LAN -SHF1                                        4                             1.35                     9.0                   90
 CAT. 7 S/FTP LAN -SHF2                                        4                             1.35                     9.0                   90
 CAT. 7 S/FTP LAN -SHF2 MUD                                    4                             1.35                     9.0                   90
approximate values
  Tested for: Oil based drilling fluid , Calcio Bromide Brine, IRM 902 and IRM 903 oils
(1)
M A D E I N ITA LY
Cavicel, Conducting Value                                                                                                                             8
LAN 7 - Flexible
S/FTP LSZH 4x2xAWG23/7 Cat.7 (up to 600 MHz)
Approved by:                                             APPLICATIONS                                          OPERATING TEMPERATURE
                                                         • Indoor/Outdoor installation in                      -20°C / +70°C (operating)
                                                           Off-shore, Oil & Gas and Marine                     -20°C / +70°C (storage)
                                                           applications                                        -5°C / +50°C (installation)
                                                         • Data transmission and
                                                           telecommunication systems                           MINIMUM BENDING RADIUS
                                                         • Structured cabling for Ethernet
                                                           networks.                                           12 times the outer diameter (static)
CABLE CONSTRUCTION                                       PAIRS COLOUR CODE                                     ELECTRICAL CHARACTERISTICS
Conductors                                               1st pair:                                             Max DC conductor resistance
Plain annealed copper wire, AWG23/7                      2nd pair:                                             73 Ω/km
                                                         3rd pair:
Insulation                                               4th pair:
                                                                                                               Max operating voltage
Foam Polyolefin                                                                                                125 Vac
Twisting/Individual screen                               APPLICABLE STANDARDS                                  Min insulation resistance
The insulated cores shall be twisted in                                                                        5000 MΩ x km
pairs and wrapped with Al/Pet tape.
                                                         Standard reference                                    Capacitance @800 Hz
Cabling                                                  IEC 61156-5; EN 50288-5-1;                            43 pF/m
The pairs are cabled together                            EN 50289-4-16; ISO/IEC 11801;                         Characteristic Impedance
                                                         NEK 606;                                              100 Ω
Overall screen
Tinned copper braid.                                     Flame retardant                                       Velocity of propagation
                                                         IEC 60332-1-2                                         >70%
Outer sheath
LSZH thermoplastic material                              Fire retardant
(SHF1 - SHF2 - SHF2 MUD resistant                        IEC 60332-3-24
compound(1))                                             Acid gas emission:
Nom. Outer diameter                                      BS EN 60754-1, BS EN 60754-2
9.00 mm                                                  Smoke density
                                                         BS EN 61034-2
                                                                                                                 Outer Diameter              Weight
                       Type                                 N° Pairs                Insulation Diameter (mm)
                                                                                                                      (mm)                   (kg/km)
 CAT. 7 S/FTP LAN -SHF1                                        4                             1.55                     9.0                     100
 CAT. 7 S/FTP LAN -SHF2                                        4                             1.55                     9.0                     100
 CAT. 7 S/FTP LAN -SHF2 MUD                                    4                             1.55                     9.0                     100
approximate values
  Tested for: Oil based drilling fluid , Calcio Bromide Brine, IRM 902 and IRM 903 oils
(1)
MA D E I N ITA LY
Cavicel, Conducting Value                                                                                                                              9
LAN 7 A
S/FTP LSZH 4x2xAWG23/1 Cat.7A (up to 1000 MHz)
APPLICATIONS                                             OPERATING TEMPERATURE                                 MINIMUM BENDING RADIUS
• Indoor/Outdoor installation in                         -20°C / +70°C (operating)                             10 times the outer diameter (static)
  Off-shore, Oil & Gas and Marine                        -20°C / +70°C (storage)
  applications                                           -10°C / +60°C (installation)
• Data transmission and
  telecommunication systems
• Structured cabling for Ethernet
  networks.
CABLE CONSTRUCTION                                       PAIRS COLOUR CODE                                     ELECTRICAL CHARACTERISTICS
Conductors                                               1st pair:                                             Max DC conductor resistance
Plain annealed copper wire, AWG23/1                      2nd pair:                                             73 Ω/km
                                                         3rd pair:
Insulation                                               4th pair:
                                                                                                               Max operating voltage
Foam Polyolefin                                                                                                125 Vac
Twisting/Individual screen                               APPLICABLE STANDARDS                                  Min insulation resistance
The insulated cores shall be twisted in                                                                        5000 MΩ x km
pairs and wrapped with Al/Pet tape.
                                                         Standard reference                                    Capacitance @800 Hz
Cabling                                                  IEC 61156-5; EN 50288-5-1;                            43 pF/m
The pairs are cabled together                            EN 50289-4-16; ISO/IEC 11801;
                                                                                                               Characteristic Impedance
                                                         NEK 606;
Overall screen                                                                                                 100 Ω
Tinned copper braid                                      Flame retardant
                                                                                                               Velocity of propagation
                                                         IEC 60332-1-2
Outer sheath                                                                                                   >70%
LSZH thermoplastic material                              Fire retardant
                                                                                                               Loop resistance
(SHF1 - SHF2 - SHF2 MUD resistant                        IEC 60332-3-22
                                                                                                               146 Ω/km
compound(1))                                             Acid gas emission:
Nom. Outer diameter                                      BS EN 60754-1, BS EN 60754-2
9.00 mm                                                  Smoke density
                                                         BS EN 61034-2
                                                                                                                 Outer Diameter            Weight
                       Type                                 N° Pairs                Insulation Diameter (mm)
                                                                                                                      (mm)                 (kg/km)
 CAT. 7 S/FTP LAN -SHF1                                        4                             1.35                     9.0                   90
 CAT. 7 S/FTP LAN -SHF2                                        4                             1.35                     9.0                   90
 CAT. 7 S/FTP LAN -SHF2 MUD                                    4                             1.35                     9.0                   90
approximate values
  Tested for: Oil based drilling fluid , Calcio Bromide Brine, IRM 902 and IRM 903 oils
(1)
M A D E I N ITA LY
Cavicel, Conducting Value                                                                                                                             10
LAN 7 A - Flexible
S/FTP LSZH 4x2xAWG23/7 Cat.7A (up to 1000 MHz)
Approved by:                                             APPLICATIONS                                          OPERATING TEMPERATURE
                                                         • Indoor/Outdoor installation in                      -20°C / +70°C (operating)
                                                           Off-shore, Oil & Gas and Marine                     -20°C / +70°C (storage)
                                                           applications                                        -5°C / +50°C (installation)
                                                         • Data transmission and
                                                           telecommunication systems                           MINIMUM BENDING RADIUS
                                                         • Structured cabling for Ethernet
                                                           networks.                                           12 times the outer diameter (static)
CABLE CONSTRUCTION                                       PAIRS COLOUR CODE                                     ELECTRICAL CHARACTERISTICS
Conductors                                               1st pair:                                             Max DC conductor resistance
Plain annealed copper wire, AWG23/7                      2nd pair:                                             73 Ω/km
                                                         3rd pair:
Insulation                                               4th pair:
                                                                                                               Max operating voltage
Foam Polyolefin                                                                                                125 Vac
Twisting/Individual screen                               APPLICABLE STANDARDS                                  Min insulation resistance
The insulated cores shall be twisted in                                                                        5000 MΩ x km
pairs and wrapped with Al/Pet tape.
                                                         Standard reference                                    Capacitance @800 Hz
Cabling                                                  IEC 61156-5; EN 50288-5-1;                            43 pF/m
The pairs are cabled together                            EN 50289-4-16; ISO/IEC 11801;
                                                                                                               Characteristic Impedance
                                                         NEK 606;
Overall screen                                                                                                 100 Ω
Tinned copper braid.                                     Flame retardant
                                                                                                               Velocity of propagation
                                                         IEC 60332-1-2
Outer sheath                                                                                                   >70%
LSZH thermoplastic material                              Fire retardant
(SHF1 - SHF2 - SHF2 MUD resistant                        IEC 60332-3-24
compound(1))                                             Acid gas emission:
Nom. Outer diameter                                      BS EN 60754-1, BS EN 60754-2
9.00 mm                                                  Smoke density
                                                         BS EN 61034-2
                                                                                                                 Outer Diameter              Weight
                       Type                                 N° Pairs                Insulation Diameter (mm)
                                                                                                                      (mm)                   (kg/km)
 CAT. 7 S/FTP LAN -SHF1                                        4                             1.55                     9.0                     100
 CAT. 7 S/FTP LAN -SHF2                                        4                             1.55                     9.0                     100
 CAT. 7 S/FTP LAN -SHF2 MUD                                    4                             1.55                     9.0                     100
approximate values
  Tested for: Oil based drilling fluid , Calcio Bromide Brine, IRM 902 and IRM 903 oils
(1)
M A D E I N ITA LY
Cavicel, Conducting Value                                                                                                                              11
LAN 7 - ARMOURED
S/FTP LSZH 4x2xAWG23/1 Cat.7 (up to 600 MHz)
Approved by:                                              APPLICATIONS                                             OPERATING TEMPERATURE
                                                          • Indoor/Outdoor installation in                         -20°C / +70°C (operating)
                                                            Off-shore, Oil & Gas and Marine                        -20°C / +70°C (storage)
                                                            applications                                           -5°C / +50°C (installation)
                                                          • Data transmission and
                                                            telecommunication systems                              MINIMUM BENDING RADIUS
                                                          • Structured cabling for Ethernet
                                                            networks.                                              20 times the outer diameter (static)
CABLE CONSTRUCTION                                        PAIRS COLOUR CODE                                        ELECTRICAL CHARACTERISTICS
Conductors                                                1st pair:                                                Max DC conductor resistance
Plain annealed copper wire, AWG23/1                       2nd pair:                                                73 Ω/km
                                                          3rd pair:
Insulation                                                4th pair:
                                                                                                                   Max operating voltage
Foam Polyolefin                                                                                                    125 Vac
Twisting/Individual screen                                APPLICABLE STANDARDS                                     Min insulation resistance
The insulated cores shall be twisted in                                                                            5000 MΩ x km
pairs and wrapped with Al/Pet tape.                       Standard reference                                       Capacitance @800 Hz
Cabling                                                   IEC 61156-5; EN 50288-5-1;                               43 pF/m
The pairs are cabled together                             EN 50289-4-16; ISO/IEC 11801;
                                                          NEK 606;                                                 Characteristic Impedance
Overall screen                                                                                                     100 Ω
Tinned copper braid                                       Flame retardant
                                                          IEC 60332-1-2                                            Velocity of propagation
Inner sheath                                                                                                       >70%
LSZH thermoplastic material                               Fire retardant
                                                          IEC 60332-3-22                                           Loop resistance
Armour                                                                                                             146 Ω/km
Galvanized steel wire braid                               Acid gas emission:
                                                          BS EN 60754-1, BS EN 60754-2
Outer sheath
LSZH thermoplastic material                               Smoke density
(SHF1 - SHF2 - SHF2 MUD resistant                         BS EN 61034-2
compound (1))
Nom. Outer diameter
12.6 mm
                                                                            Insulation Diameter   Outer Diameter           Outer Diameter        Weight
                      Type                              N° Pairs
                                                                                    (mm)               (mm)                     (mm)             (kg/km)
 CAT. 7 S/FTP LAN -SHF1                                    4                      1.35                 9.0                     12.6               200
 CAT. 7 S/FTP LAN -SHF2                                    4                      1.35                 9.0                     12.6               200
 CAT. 7 S/FTP LAN -SHF2 MUD - GSWB                         4                      1.35                 9.0                     12.6               200
approximate values
(1)
    Tested for: Oil based drilling fluid , Calcio Bromide Brine, IRM 902 and IRM 903 oils
M A D E I N ITA LY
Cavicel, Conducting Value                                                                                                                                  12
LAN 7A - ARMOURED
S/FTP LSZH 4x2xAWG23/1 Cat.7A (up to 1000 MHz)
Approved by:                                              APPLICATIONS                                             OPERATING TEMPERATURE
                                                          • Indoor/Outdoor installation in                         -20°C / +70°C (operating)
                                                            Off-shore, Oil & Gas and Marine                        -20°C / +70°C (storage)
                                                            applications                                           -5°C / +50°C (installation)
                                                          • Data transmission and
                                                            telecommunication systems                              MINIMUM BENDING RADIUS
                                                          • Structured cabling for Ethernet
                                                            networks.                                              20 times the outer diameter (static)
CABLE CONSTRUCTION                                        PAIRS COLOUR CODE                                        ELECTRICAL CHARACTERISTICS
Conductors                                                1st pair:                                                Max DC conductor resistance
Plain annealed copper wire, AWG23/1                       2nd pair:                                                73 Ω/km
                                                          3rd pair:
Insulation                                                4th pair:
                                                                                                                   Max operating voltage
Foam Polyolefin                                                                                                    125 Vac
Twisting/Individual screen                                APPLICABLE STANDARDS                                     Min insulation resistance
The insulated cores shall be twisted in                                                                            5000 MΩ x km
pairs and wrapped with Al/Pet tape.                       Standard reference                                       Capacitance @800 Hz
Cabling                                                   IEC 61156-5; EN 50288-5-1;                               43 pF/m
The pairs are cabled together                             EN 50289-4-16; ISO/IEC 11801;
                                                          NEK 606;                                                 Characteristic Impedance
Overall screen                                                                                                     100 Ω
Tinned copper braid                                       Flame retardant
                                                          IEC 60332-1-2                                            Velocity of propagation
Inner sheath                                                                                                       >70%
LSZH thermoplastic material                               Fire retardant
                                                          IEC 60332-3-22                                           Loop resistance
Armour                                                                                                             146 Ω/km
Galvanized steel wire braid                               Acid gas emission:
                                                          BS EN 60754-1, BS EN 60754-2
Outer sheath
LSZH thermoplastic material                               Smoke density
(SHF1 - SHF2 - SHF2 MUD resistant                         BS EN 61034-2
compound (1))
Nom. Outer diameter
12.6 mm
                                                                            Insulation Diameter   Outer Diameter           Outer Diameter        Weight
                      Type                              N° Pairs
                                                                                    (mm)               (mm)                     (mm)             (kg/km)
 CAT. 7 S/FTP LAN -SHF1                                    4                      1.35                 9.0                     12.6               200
 CAT. 7 S/FTP LAN -SHF2                                    4                      1.35                 9.0                     12.6               200
 CAT. 7 S/FTP LAN -SHF2 MUD - GSWB                         4                      1.35                 9.0                     12.6               200
approximate values
(1)
    Tested for: Oil based drilling fluid , Calcio Bromide Brine, IRM 902 and IRM 903 oils
MA D E I N ITA LY
Cavicel, Conducting Value                                                                                                                                  13
QUALITY IS OUR
    BUSINESS
Conducting Value
            Conducting Value
    CAVICEL SpA
    Via Caduti del Lavoro, 18/A
    20096 Pioltello (Milano)
    Italy
    ph. +39 - 02 - 921.605.21
    fax +39 - 02 - 921.607.53
    e-mail: cavicel@cavicel.com
    DUBAI BRANCH OFFICE
    Fortune Executive Tower
    Office 406 - Plot No. T1
    Jumeirah Lakes Towers
    Dubai - UAE - PO Box 634377
    ph. +971 4.4581199
    fax +971 4.4581144
    e-mail: middleeast@cavicel.com
    HONG KONG OFFICE
    12/F, THE GRID
    133 Wai Yip Street, Kwun Tong
    Hong Kong
    ph: +852 9472 3067
    e-mail: apac@cavicel.com
    www.cavicel.com
     MADE IN ITALY
Cavicel firmly believes in the importance of the quality of its products and it undertakes itself to produce them using clean technologies for the respect and the protection of the environment.
                                                                                                   _
             All information contained in this brochure is believed to be accurate. Specifications can change at any time, according to technical developments and market changes.
                      All rights reserved. No part of this document may be reproduced in any form or by any means, without the prior written permission from Cavicel SpA.