SCHEDULE OF DOOR & WINDOW

SL NAME DIMENSION SILL LINTEL


DESCRIPTION
IN MTRS IN MTRS IN MTRS
1 D 1.5 X 2.1 - 2.1 M PANELLED DOOR
2 D1 0.90 X 2.1 - 2.1 M PANELLED DOOR
3 D2 0.8 X2.1 - 2.1 M PANELLED DOOR
4 D3 1.0 X2.1 - 2.1 M PANELLED DOOR
5 D4 1.5X2.6 - SLIDING DOOR
6 V 0.60 X 1.2 1.5 M 2.1 M GLAZED WOODEN
7 W1 2 X 1.35 0.762 M 2.1 M GLAZED ALUMINIUM WINDOW

CALCULATION FOR SOLAR HOT WATER SYSTEM


NO.OF SOLAR CAPACITY TOTAL SOLAR NOS.OF PANELS
SL DESCRIPTION PER FLAT (LPD) CAPACITY(LPD)
FLATS PROVIDED(125LPD)
7M WIDTH D R I V E W A Y P31 P31 P32 P33 P34 P35 P36 P37 P38 P39 P40 T-1 S+12 46 100
P41 P42 4600 24
T-2 S+12 72 100 7200 39

BASEMENT 2 RAMP DOWN


NOTES:
FIRE LIFT

S. LIFT ·ALL DIMENSIONS ARE IN METERS.


2.2MX3M

WAY TO BASEMENT 2
FIRE ROOM
7MX6M
D4
ELECTRICAL ROOM 6M WIDTH D R I V E W A Y ·WRITTEN DIMENSION SHOULD BE FOLLOWED.
D4
7MX6M
·DRAWING MUST NOT BE SCALED.
FIRE STAIRCASE
P77
3.5MX5.5M D
FRD
D D

D
P76
PUMP ROOM

12M WIDTH D R I

6.5M WIDTH D R I
P43 P44 P45 P46 P48 P49 P50 P51 P52
P47 P75

LIFT D4
P74

P24 P25 P26 LIFT D4

P73
FIRE STAIRCASE

V E

V E
STAIRCASE
P72
AREA AND BUILDING PARAMETERS
D4 FIRE LIFT
D FRD

W
AREA-8266 SQM

A Y

A Y
D4 S.LIFT
P71

P53 P54 P55 P56 P57 P58 FAR-3


PERMISSIBLE(BUA)=8266X3=24798
D4 D4
ELE.ROOM
3MX2.4M
P27 P28 P29 P30
6M WIDTH D R I V E W A Y
GROUND COVERAGE-40%
LIFT LIFT STAIRCASE
3.5MX5.5M BUILDBLE AREA=3166M.SQR
6.5M WIDTH D R I V E W A Y

P59 P60 P61 P62 P63 P64 P65 P66 P67 P68 P69 P70 3.5 BHK UNIT PLAN
AREA=158

2.5 BHK UNIT PLAN


AREA=135

BASEMENT1

LIST OF SHEETS
7M WIDTH D R I V E W A Y P93 P94 P95 P96 P97 P98 P99 P100 P101 P102 P103 P104 P105
SL.NO. DESCRIPTION SHEET NO.

1. SITE PLAN 01
2. BASEMENT FLOOR PLAN 02
3. STILT FLOOR PLAN 03
4. TOWER 1 AND TOWER 2 FLOOR PLANS 04
FIRE LIFT

S. LIFT
5. SECTIONS 05
2.2MX3M
D4 6. TOWER 1 ELEVATIONS 06
6M WIDTH D R I V E W A Y
D4
P80 P81 P82 P83 P84 7. TOWER 2 ELEVATIONS 07
P78 P79 P138
FIRE STAIRCASE
3.5MX5.5M

FRD
D SPACE FOR AUTHORITY:

P137
12M WIDTH D

6.5M WIDTH D
P106 P107 P108 P109 P010 P111 P112 P113 P114 P115 P136

TWO WHEELER LIFT D4 P135


PARKING P116
R

P85 P86 P87 P88

R
LIFT D4

P134
I

I
P117 FIRE STAIRCASE
V

V
E. V
CHARGING POINT
E

E
STAIRCASE
D4 FIRE LIFT P133
P118 D FRD
W

W
A

NORTH
S.LIFT
P132
D4
Y

Y
SHEET NO.: SCALE:
01
1:200
D4 D4 (TO BE PRINTED IN A1 SIZE)
ELE.ROOM P89 P90 P91 P92
3MX2.4M 6M WIDTH D R I V E W A Y
LIFT LIFT STAIRCASE
3.5MX5.5M

The drawing has been prepared as per the ODA


(Planning & Building Standards) Rules, 2020.
6.5M WIDTH D R I V E W A Y

P119 P120 P121 P122 P123 P124 P125 P126 P127 P128 P129 P130 P131
NAME-PRAVAT KUMAR SAMAL
REG NO-2202295043
SEM-7 SEC-B

SEAL & SIGN OF SEAL & SIGN OF


TECHNICAL PERSON: MEP CONSULTANT:

APPLICANT'S SIGN:

BASEMENT2