PN 91-6020/rev.
B April 2006
Liquid Division
Mounting Solutions
INTRODUCTION:
Rosemount Analytical, Inc, Liquid Division is pleased to offer a variety of sensor mounting options to fit many demanding process needs. Mounting tees, ball valve kits, advanced automated assemblies, and other configurations used for mounting conductivity, pH, and amperometric (dissolved oxygen, chlorine, and ozone) sensors are listed on the following pages. Please note that each mounting accessory is only valid for the stated sensors. Sensors must be purchased separately. The mounting accessories found in this brochure can be used in a wide variety of applications commonly found in the following industries:
Pulp and Paper
Chemical
Metals and Mining
Food and Beverage
Hydrocarbon Processing
Water Treatment
Textile
Utilities
Pharmaceutical
The symbol for each industry is noted on each page if it is a mounting solution commonly used in the industry. Also, for some accessories, specific examples of the applications are noted. The following mounting accessories are helpful for mounting sensors in ponds, pipes, and tanks and for tapping into lines. Some mounting assemblies are designed to be used with only conductivity, amperometric, or pH sensors.
MOUNTING SOLUTIONS INDEX
MOUNTING ACCESSORY
In-Line Tees
INDUSTRIES TYPICALLY FOUND IN
USED FOR:
Direct in-line insertion of sensor 1/4 inch connection to existing piping, or needing minimal flow for measurement Quick access to sensor without cable twisting Insertion into ponds and tanks Sensor cleaning in ponds and tanks Adapting sensors into existing pipelines Processes that cannot be shut down for service or where long insertion length is needed for sensor to fit into large diameter pipes Adapting sensors into existing pipelines High pressure processes
PAGE
4
Low Flow Cell
Quik-Loc Assembly
Handrail Mounting Assembly Jet Spray Cleaner
10
12
Mounting Adapters
14
Ball Valve Kits
16
Process Connectors
20
Valve Insertion Assemblies Rotary Retraction Valve - PASVE
26
Processes that cannot be shut down for servicing sensor
28
Choosing the right mounting solution Sensor to Mounting Accessory Capability Chart Compatible Sensors
36 38 39
IN-LINE TEES
COMMON INDUSTRIES:
Metals & Mining
Food & Beverage
Hydrocarbon Processing
Municipal
Textile
Utilities Pharmaceutical
Used with conductivity, dissolved oxygen, chlorine, ozone, and pH sensors Installed directly into pipelines and slip streams in the process plant Compatible with various sizes of process lines. Adapters (offered on most tees) allow easy removal of sensors without twisting cables. Used in a wide variety of applications including (but not limited to): * Wastewater and sour gas scrubbers lines in the Hydrocarbon Processing Industry * Sanitation water lines containing ozone, chlorine, or bromine in the Pharmaceutical or Food & Beverage Industries * Cooling water sample manifolds found in many industries IN-LINE TEE PART NUMBER 2002011
Tee Size Adapter Thread Size Process Connection Ends Tee Material O-Ring/Gasket Material Maximum Rating Compatible pH Sensor Models Compatible Amperometric Sensor Models Compatible Conductivity See Figure 1.5 in. 1.0 in. threads CPVC, Schedule 80
23567-00
1.5 in. 1.0 in. 1.5 in. socket CPVC, Schedule 80 Buna N
915240-03
2.0 in. 1.0 in. 3/4 in. threads PVC, Schedule 80 Buna N
915240-04
2.0 in. 1.0 in. 1.0 in. threads PVC, Schedule 80 Buna N
915240-05
2.0 in. 1.0 in. 1.5 in. threads PVC, Schedule 80 Buna N
150 psig (1136 kPa) 65 psig (549 kPa) 60 psig (514 kPa) 60 psig (514 kPa) 60 psig (514 kPa) @ 150F (65C) @ 122F (50C) @ 120F (49C) @ 120F (49C) @ 120F (49C) 396*, 396P, 389, 399, 385+* 396*, 396P, 389, 399, 385+* 396P, 389, 399 396P, 389, 399 396P, 389, 399
499ADO, 499ACL 499ADO, 499ACL 499ADO, 499ACL 499ADO, 499ACL 499ADO, 499ACL 499AOZ 499AOZ 499AOZ 499AOZ 499AOZ 150 Sensor Models 1 3 2 2 2
* Sensor must use a process connector; see page 20 for connector part numbers. INSTALLATION NOTES: 1. Sensing tip of sensor should be wetted at all times with process liquid. 2. Allow at least 3.5 in. (90 mm) head room for sensor removal. 3. To ensure proper sensor performance, sensor must be mounted at least 10 degrees above the horizontal. Side view of Tee PN 915240-03, -04, or -05 with Model 399 shown in middle of process flow. See Figure 2 for dimensional drawing. Model 399 shown in Tee PN 915240-03, -04, or -05. Tee is available with 3/4 in., 1 in., or 1-1/2 in. NPT process connection threads. See Figure 2 for dimensional drawing.
IN-LINE TEES (continued)
IN-LINE TEE (PN 2002011) PRESSURE/TEMPERATURE SPECIFICATIONS psig (kPa) 150 (1136) 128 (984) 102 (805) 80 (653) 57 (494) 48 (432) F (C) 150 (65) 160 (71) 170 (77) 180 (82) 200 (93) 210 (99)
FIGURE 1. 1 in. tee with 1 in. threaded process connection (PN 2002011) shown with a TUpH Model 396P mounted for angle or straight process flow.
FIGURE 2. 2 in. tee with , 1, or 1 in. threaded process connections (PN 915240-03, -04, -05 respectively) shown with a Model 499A amperometric sensor. The tee assembly is offered with a sensor mounting adapter that allows the user to remove the sensor without twisting the cable.
FIGURE 3. 1 in. tee with 1 in. socket process connection (PN 23567-00) shown with a Model 499A amperometric sensor. The tee assembly is offered with a sensor mounting adapter that allows the user to remove the sensor without twisting the cable.
LOW FLOW CELL:
COMMON INDUSTRIES:
Food and Beverage
Municipal
Utilities
Pharmaceutical
Used with dissolved oxygen, ozone, chlorine, and pH sensors Tap into existing piping and connect to 1/4" tubing Easy access to sensor without process shutdown Perfect for applications where large volumes of the process slip stream cannot be wasted to drain Clear, see-through plastic chamber allows visual inspection of the process stream Allows regulation of flow rate when used with a valved rotameter (sold separately) Ideal for applications such as * Can and bottle sanitation using ozone, chlorine, or bromine in the Food and Beverage Industry * Sanitation for Pharmaceutical applications * Ultra Pure Water measurements in the Power and Semiconductor Industry * Ozone contact tanks typically found in potable water plants
Low Flow Cell Part Number 23728-00 Process Connection Wetted Materials Maximum Temperature Maximum Pressure Compatible pH Sensors Compatible Amperometric Sensors 1/4 inch 316 SST male tube connector Body - Acrylic; Nut - CPVC; Fitting - 316 SST; Seals - Buna N 122F (50C) 65 psig (547 kPa) 396*, 396P, 399, 389, 385+* 499A DO, 499A CL, 499A OZ
* Sensor must use a process connector; see page 20 for connector part numbers.
LOW FLOW CELL (continued)
PN 24091-01 has bubble sweeping nozzle for low flow applications (2 to 3 gph).
FIGURE 4. Low Flow Cell (PN 24091-00 or 24091-01)
REQUIRED FLOW RATES (Optional Rotameters sold separately):
Sensor Model All pH sensor models 499A CL 499A DO 499A OZ Flow Rate 2 - 5 g/hr (7.6 - 19 L/hr) 8 - 15 g/hr (30 - 57 L/hr) 2 - 5 g/hr (7.6 - 19 L/hr) 2 - 5 g/hr (7.6 - 19 L/hr) Recommended Valved Rotameter PN 9390004 or PN 196-898754 PN196-898754 PN 9390004 PN 9390004
Optional Overflow Sampler
Low Flow Cell VALVED ROTAMETERS (Used with the Low Flow Cell):
All sensors
3 g/hr
PN 24035-00
PN 9390004 (see Figure 4) PN 196-898754 (see Figure 4) Range of Flow Regulated 0.4 - 5.0 g/hr (1.5 - 19.0 L/hr) 2.0 - 20.0 g/hr (7.6 - 76.0 L/hr) Wetted Parts acrylic, 316 SST, Viton polycarbonate, 316 SST, brass, Buna N Process Connection 1/4 inch FNPT (316 SST) 1/8 inch FNPT (brass) Maximum Pressure Maximum Temperature 100 psig (790 kPa) 150F (65C) 100 psig (790 kPa) 130F (54C)
PN 24035-00 3 g/hr 11 L/hr acrylic, polycarbonate, kynar, nylon, silicone 1/4 inch OD tubing compression fitting 3 to 65 psig (122 to 549 kPa abs) 0 to 50C
THE QUIK-LOC ASSEMBLY:
COMMON INDUSTRIES:
Chemical
Metals & Mining
Hydrocarbon Processing
Textile
PEEK Adapter
DIXON 316 SST Coupler
QUIK-LOC KIT WITH TUpH MODEL 397 pH SENSOR
Designed for use with TUpH Model 397 pH Sensor Unique design eliminates cable twisting Quick and easy sensor access by simple release of the coupler arms Coupler arms lock in place when sensor is in use Used in applications needing a quick disconnect solution: * Coagulation and flocculation, waste neutralization, and scrubbers found in the Chemical Industries * Waste water lines and crude overhead towers found in the Hydrocarbon Processing Industries * Batch tanks typically found in the Food and Beverage Industry
PN 23757-00 Process Connection Wetted Materials 1 inch MNPT Coupler - 316 SST Gasket - EP Adapter - PEEK 32 - 176F (0 - 80C) 0 - 100 psig (100 - 790 kPa) 1.4 in./35 mm 397
PN 23757-01 1 inch MNPT Coupler - 316 SST Gasket - EP Adapter - PEEK 32 - 176F (0 - 80C) 0 - 100 psig (100 - 790 kPa) 2.0 in./50 mm 397
Temperature Rating Pressure Rating Sensor Insertion Depth Compatible pH Sensor
THE QUIK-LOC ASSEMBLY (continued):
FIGURE 5. Quik-Loc mounting assembly (PN 23757-00, -01) shown with TUpH Model 397 pH sensor.
FIGURE 6. Unassembled view of the TUpH Model 397 pH sensor and the Quik-Loc assembly. 9
HANDRAIL MOUNTING ASSEMBLY:
COMMON INDUSTRIES:
Metals & Mining
Food & Beverage
Municipal
Textile
Utilities
Pharmaceutical
Used with pH, dissolved oxygen, and chlorine sensors Excellent for use in tanks, aeration basins, or open channels where levels may vary Mounts easily onto handrail Sensor can be removed from tank or basin quickly and easily for servicing Assembly can be inserted to various depths Can be used with the Jet Spray Cleaner (see page 12) for dirty applications
Part Number 11275-01 Process Connection Wetted Materials Temperature Rating Compatible pH Sensors Compatible Amperometric Sensors Optional Accessory Mounting brackets for various sizes of handrails PVC 140F (60C) max. 396*, 396P, 399, 389, 385+* 499A DO**, 499A CL**, 499A OZ** The Jet Spray Cleaner (see page 12)
* Sensor must use a process connector; see page 20 for connector part numbers. ** If used with the Handrail Mounting Assembly in a tank, remember that a correct measurement can only be made if there is a continuous flow pass the membrane of the sensor. These sensors will not operate properly in standing liquid.
10
HANDRAIL MOUNTING ASSEMBLY (continued):
FIGURE 7. Handrail Mounting Assembly (PN 11275-01) shown with Model 499A Dissolved Oxygen Sensor. 11
FLOATING BALL SYSTEM
COMPATIBLE WITH ROSEMOUNT Dissolved Oxygen Sensor Model 499ADO MAINTAINS CONSTANT SENSOR DEPTH regardless of changes in liquid or tank level EXTENDED BUOYANCY supports sensor weight with reserve capacity ACCEPTS ANY SENSOR WITH 1 INCH REAR FACING MNPT CONNECTION The Floating Ball System provides the flexibility to position the sensor almost anywhere in the basin SYSTEM DESCRIPTION
The materials of construction of the floating ball is thick walled flexible PVC material, and includes PVC elbows and fittings to angle the sensor into the process and prevent air bubbles from becoming trapped and prevent erratic sensor readings. The floating ball will accommodate a pipe boom using a 1-1/2 inch diameter Schedule 80 PVC pipe.
MODEL BB11
The Model BB11 is available in three model options. The model BB11-01 is designed for DO Sensor Model 499ADO and includes the sensor union adapter. The sensor can be removed without twisting the cable.
Model BB11-01 for DO Sensor Model 499ADO with sensor union adapter 12
FLOATING BALL MODEL BB11-02 WITH OPTIONAL HANDRAIL MOUNTING SYSTEM MODEL HRMS-02
MODEL BB11-02
The model BB11-02 can be used with DO sensor with Washer Head Assembly.
MODEL BB11-03
The Model BB11-03 is designed for any sensor with a 1 inch rear facing MNPT connection and includes a PVC union for removing the sensor without twisting the sensor cable.
Model BB11-02 for DO Sensor Model 499ADO and Washer Head Assembly
Model BB11-03 for any Sensor with a 1 inch Rear Facing MNPT Connection
REMOVING DISSOLVED OXYGEN SENSOR FROM SENSOR UNION ADAPTER
DISSOLVED OXYGEN MEASUREMENT SYSTEM WITH AIR BLAST CLEANER
The Air Blast Sensor Cleaner, which includes the washer head and air compressor, keeps the sensor membrane clean At programmed intervals, the air blast cleaner blows a stream of air across the membrane to clear bio-film from on the membrane.
SPECIFICATIONS - COMPRESSOR FOR AIR BLAST CLEANER SYSTEM
Enclosure: Fiberglass reinforced polyester with polyester cover, NEMA 4x (IP65). 11.9 x 11.9 x 6.9 in (302 x 302 x 175 mm). Compressor: Oil-less, non-lubricating piston and cylinder. 1/12 HP permanent split capacitor motor with thermal overload protection. Maximum continuous pressure: 50 psig (446 kPa abs) Operating pressure: 20 psig (239 kPa abs) Air hose: 25 ft (7.6 m) included with ABSH Ambient temperature: 5 to 122F (-15 to 50C) assuming intermittent operation Power: Code -03: 115 VAC, 60 Hz or 100 VAC, 50/60 Hz, single phase,1.3 to 1.4 A, starting current 3.88 A, insulation class B; UL approved Code -04: 220 VAC, 50 Hz, single phase, 0.6 A, starting current 1.5 A, insulation class A; CE approved
SPECIFICATIONS - HANDRAIL MOUNTING ASSEMBLY
Materials of Construction: Weather cap: Schedule 40 PVC Pipe clamp and bracket: Aluminum Clevis: zinc-plated steel U-bolts, nuts, and bolts: zinc-plated steel Washers: stainless steel
PLANT AIR SYSTEM REQUIREMENTS (for customers using plant air in place of air compressor)
Pressure: 20 psig (239 kPa abs) Flow: 0.50 SCFM (14 L/min at STP) Air hose: (customer supplied) compatible with inch barbed fitting for connection at washer head
SPECIFICATIONS - AIR BLAST CLEANER SYSTEM WASHER HEAD
Process connection: 1-1/2 inch PVC pipe socket Dimensions (diameter x length): 2-1/2 x 10-3/4 inches (64 x 273 mm) Wetted materials: PVC, Noryl, Viton Pipe boom: 1-1/2 inch schedule 80 PVC, maximum length 12 feet (3.6 m) past handrail mounting clamp. Pipe boom is supplied by customer. Maximum distance between compressor and sensor: 25 ft (7.6 m). ABSH is supplied with 25 ft (7.6 m) of air hose. 14
WHEN INCH AND METRIC DIMS ARE GIVEN INCH MILLIMETER
ENCLOSURE DIMENSIONS
STANDARD SENSOR WITH INTEGRAL CABLE
AIR BLAST WASHER HEAD
15
JET SPRAY CLEANER:
COMMON INDUSTRIES:
Metals & Mining
Food & Beverage
Municipal
Textile
Utilities
Pharmaceutical
JET SPRAY CLEANER SHOWN WITH TUpH MODEL 396P pH SENSOR Compatible with pH and amperometric sensors Can be used with the Handrail Mounting Assembly (see page 10) Cleans sensor tip using water, cleaning solutions, or compressed air Eliminates routine, manual maintenance For dirty or coating liquids typically found in waste water aeration basins or influent channels The cleaning spray can be controlled by a solenoid valve operated by the interval timer relay found in the Models 54, 1054A series, and 1054B series analyzers.
Part Number 12707-00 Process Connection Wetted Materials Compatible pH Sensors Compatible Amperometric Sensors 2 in. NPT threads OR use sensor/conduit 316 SST, polypropylene, PVC 396P, 389, 399 499A CL, 499A DO, 499A OZ
16
JET SPRAY CLEANER (continued):
FIGURE 8. Jet Spray Cleaner (PN 12707-00) shown with Model 399 pH sensor. The Jet spray Cleaner can be used with the Handrail Mounting Assembly. 17
MOUNTING ADAPTERS:
COMMON INDUSTRIES:
Metals & Mining
Food & Beverage
Hydrocarbon Processing
Municipal
Textile
Utilities
Used with conductivity, pH, dissolved oxygen, chlorine, and ozone sensors Perfect for any application with process connection thread sizes larger than sensor thread sizes; allows the sensor to mount in various process situations: * Pipe Mounting Accessory mounts sensor on end of pipe for submersion into tanks and ponds * Insertion Adapter is used for mounting sensor in pipe tees; sensor can be removed without cable twisting ADAPTER Materials of Construction Process Connection Sensor Adapter/Union Thread Size Sensor Compatibility Figure Number 23242-02 316 SST, PEEK, Viton 1 in. MNPT 1 in. x 3/4 in. 228, 499A, 389, 396P, 399 9, 12 23242-03 316 SST, PEEK, Viton 1 in. MNPT 3/4 in. x 5/8-11 UNC 228 10, 12 9330022 CPVC 1 in. FNPT 1 in. FNPT 396*, 396P, 389, 399, 385+* 11
* Sensor must use process connector. See page 20 for connector part numbers.
FIGURE 9. Model 396P pH Sensor shown with Adapter PN 23242-02 18
FIGURE 10. Model 228 Toroidal Conductivity Sensor shown with Adapter PN 23242-03
MOUNTING ADAPTERS (continued):
The Pipe Mounting Accessory (PN 9330022) is ideal for connecting a sensor to a pipe for insertion into a pond, tank, aeration basin, or open channel.
FIGURE 11. Example of pipe mounting sensor with mounting adapter
FIGURE 12. Insertion Mounting Adapter (PN 23242-02, -03)
*NOTE: PEEK ADAPTER IS OFFERED IN TWO VERSIONS: A) 3/4 X 1 IN. NPT ADAPTER THAT IS USED FOR 1 OR 3/4 IN. SENSORS (ORDER MOUNTING ADAPTER PN 23242-02) B) 5/8-11 UNC X 3/4 NPT ADAPTER THAT IS USED FOR MODEL 228 SENSORS (ORDER MOUNTING ADAPTER PN 23242-03)
The Insertion Adapter mounts sensors into a 1-1/2 inch NPT process pipe. Unscrewing the hex nut allows easy sensor removal without twisting the sensor cable.
19
BALL VALVE KITS:
COMMON INDUSTRIES:
Pharmaceutical Pulp & Paper
Chemical
Metals & Mining
Hydrocarbon Processing
Textile
Utilities
Used with retractable conductivity and pH sensors Can be installed in large pipes or tanks, with or without the use of weldalets Allows removal of the sensor from the process under operating conditions Perfect choice for process lines that cannot be shut down when sensor maintenance must be performed Proven in pulp and paper, chemical, and other severe process applications Conductivity measurements using Ball Valve Kits include: * Demineralizer process water, reused evaporator condensate, and whitewater applications in the Pulp and Paper Industry * Water/organic separators and demineralizer water applications typically found in the Hydrocarbon and Chemical Industries * Bulk/raw ingredients in the Pharmaceutical Industry pH measurements using Ball Valve Kits include: * Headbox, whitewater and stock prep applications in the Pulp and Paper Industry * Waste neutralization, coagulation and flocculation, and scrubber applications in the Chemical Industries * Hydrogenations, Hydroxylation, and bulk/raw ingredients in the Pharmaceutical Industry
Process Connections Wetted Materials Temperature Rating Pressure Rating Maximum Retraction Pressure pH Sensors Conductivity Sensors Other necessary parts to install sensor Figure Number
1 in. Ball Valve Kit (PN 23240-00) 1 in. FNPT 316 SST 32 - 212F (0 - 100C) 100 psig (790 kPa) For 21 inch pH sensors: 64 psig (542 kPa) For 36 inch pH sensors: 35 psig (343 kPa) 396R, 398R, 385, 385+ Process connector* 14
1 in. Ball Valve Kit (PN 23765-00 and 23765-01) 1 in. MNPT 316 SST 32 - 212F (0 - 100C) 200 psig (1481 kPa) 64 psig (542 kPa) for all Model 400 conductivity sensors 402 None 15
* When using a 396R or 398R, the customer must use Process Connector (ordered separately) PN 23166-00 or 233166-01 to connect sensor to ball valve kit. Process Connector is included with the 385 and 385+ retractable sensors. INSTALLATION NOTES: 1. All pH sensors must be mounted at least 10 above the horizontal. 2. For the best performance, all conductivity sensors should be oriented with the open end of the sensor facing the process flow with the process flowing into the sensor tip.
20
BALL VALVE KITS (continued)
FIGURE 13. Common ball valve mounting shown with pH sensor and optional sensor-mounted junction box.
21
BALL VALVE KITS (continued)
B MM/IN 327.7/12.9 660.0/27.4 A MM/IN 586.2/23.1 954.5/37.58 SENSOR TUBE LENGTH 21 in. 36 in.
FIGURE 14. 1 in. FNPT Ball Valve Kit (PN 23240-00) shown with process connector (sold separately) and TUpH Model 396R pH sensor.
Ball valve kit includes a 1 in. full port ball valve, a 1 in. to 1 in. reducer, and a 1 in. close nipple. A process connector is required to connect sensor to the ball valve kit. See page 20 for process connector options.
Ball Valve Kit (PN 23240-00) used with Models 396R, 398R, 385, and 385+ pH retractable sensors
A process connector (PN 23166-00 or -01) must be used to connect the sensor to Ball Valve Kit 23240-00. Process connector can be purchased separately for use with Models 396R and 398R. The process connector is provided with Models 385 and 385+ retractable pH sensors.
22
BALL VALVE KITS (continued)
Ball Valve Kit PN 23765-00 (or 23765-01) used with Endurance Model 402 Conductivity Sensor
FIGURE 15. 1 in. MNPT Ball Valve Kit (PN 23765-00 or 23765-01) shown with retraction kit and Endurance Model 402 conductivity sensor.
Ball valve kit includes a 1 in. full port ball valve, a 1 in. MNPT nipple, and a retraction kit.
23
PROCESS CONNECTORS:
COMMON INDUSTRIES:
Pharmaceutical
Pulp & Paper
Chemical
Metals & Mining Food & Beverage
Hydrocarbon Proc. Municipal
Textile
Utilities
Required for process connection of non-threaded pH sensors for direct pipe or ball valve mounting Compression fitting holds the sensor body in place Allows for variable sensor insertion depth Sensor cable twisting is avoided Necessary accessory for first time installation of retractable pH sensor to ball valve kit PN 23240-00 (included accessory with Models 385 and 385+ retractable sensors; must purchase separately with Models 385+ [non-retractable], 396R, and 398R). PN 23166-00 PN 23166-01 Titanium 385+, 396, 398, 396R, 398R EPDM PN 9550220 Kalrez 1 in. MNPT 17 PN 9510066 Nylon 396, 398 Polyethylene 1 in. MNPT 16
Wetted Materials Compatible Sensors O-ring Material Optional O-ring PN and Material Process Connection Size Figure Number
316 Stainless Steel 385+, 396, 398, 396R, 398R EPDM PN 9550099 Viton 1 in. MNPT 17
Nylon Process Connector PN 9510066 can be used for insertion or submersion sensor connection
Metal Process Connector PN 23166-xx (xx = 00 for 316 SST and xx = 01 for titanium) can be used for insertion or submersion sensor connection
24
PROCESS CONNECTORS:
Nylon Process Connector shown with Model 396 pH sensor. Process threads can be switched for use in in-line tees or submersion pipes.
FIGURE 16. Nylon process connector (PN 9510066) shown with TUpH Model 396 pH sensor.
Must be used for low pressure, non-aggressive chemical processes only.
The metal process connector gives the sensor various insertions depths, depending on where the user locates the compression fitting. Also the threads can be switched to face the cable end of the sensor for connection to submersion pipes.
FIGURE 17. Metal process connector (PN 23166-00 [316 SST] or PN 23166-01 [titanium]) shown with TUpH Model 396 pH sensor.
This process connector can be used for all Model 396 and 385+ installations. Also, it must be used for Model 396R and 398R installations with or without a ball valve. See page 18 for ball valve drawing.
25
VALVE INSERTION ASSEMBLIES:
COMMON INDUSTRIES:
Pulp & Paper Used with Toroidal Conductivity Sensor Model 228
Chemical
Hydrocarbon Processing
Easy insertion/retraction of sensor in process conditions up to: 295 psig (2036 kPa) and 392F (200C) with the mechanical assembly 35 psig (241 kPa) and 266F (130C) with the manual assembly Convenient isolation of sensor from process for cleaning (using flush ports) or replacement Choice of mechanical or manual assembly Used with 1 1/2 " full port ball valve (purchased separately as PN 9340065) Recommended for Separators and Scrubbers typically found in the Chemical and Hydrocarbon Processing Industries Also used in CIP solutions and concentration control for the Chemical Industry Excellent for use in the white liquor alkali, brown stock washing, and green liquor alkali processes found within the Pulp and Paper Industry
PART NUMBER 23311-00 Process Connection Wetted Materials Maximum Operating Temperature Maximum Operating Pressure Max. Insertion/Retraction Conditions Maximum Insertion Travel Maximum Insertion Travel using PN 9340065 Ball Valve Compatible Conductivity Sensors Figure Number 1-1/2 in. MNPT 316 SST, Teflon, EP 392F (200C) 295 psig (2036 kPa) 392F (200C) 295 psig (2036 kPa) 8.5 in. (21.6 cm) 6.25 in. (15.9 cm) 228 18
PART NUMBER 23311-01 1-1/2 in. MNPT 316 SST, Teflon, EP 392F (200C) 295 psig (2036 kPa) 266F (130C) 35 psig (241 kPa) 12 in. (30 cm) 7.0 in. (17.8 cm) 228 19
26
VALVE INSERTION ASSEMBLIES (continued)
MECHANICAL ASSEMBLY SHOWN WITH MODEL 228 TOROIDAL SENSOR
MANUAL ASSEMBLY SHOWN WITH MODEL 228 TOROIDAL SENSOR
FIGURE 18. Mechanical Retraction/Insertion Assembly (PN 23311-00)
FIGURE 19. Manual Retraction/Insertion Assembly (PN 23311-01) 27
PASVE ROTARY RETRACTION VALVE:
COMMON INDUSTRIES:
Pulp & Paper
Mining
Chemical
Pharm
Food & Beverage
Textile
Used with Rosemount Analytical's Models 389, 396, 396P, 398 pH sensors Can be mounted on pipe lines, tanks, or directly in-line Ideal for mounting pH sensors in Headbox, whitewater, and stock preparation lines in the Pulp and Paper Industry Also used in waste neutralization, coagulation and flocculation, and scrubbers typically found in the Chemical Industry Ideal for COP (clean-out-of-place) and bulk ingredients in the Pharmaceutical and Food & Beverage Industries
Suited for on-line mounting up to 150 psig Excellent for use in pulp stock lines Also great for dirty, coating, and/or abrasive applications typically found in the Pulp and Paper, Chemical, and Mining Industries Patented, Unique Rotary valve design provides cleaning and calibrating without sensor removal or process shutdown Manual or Automatic rotation available Extended sensor life: Sensor can rotate into process for critical measurement, then rotate out and flushed with water until next measurement time is needed. Especially good when used in harsh processes.
Code C Process Connection Figure Number Wetted Materials (Valve) Wetted Materials (Seals) Welded on Tank 20, 24, 28
Code P Welded on Pipe 20, 24, 28 AISI 316LSST or Titanium PTFE (Teflon) or PTFE (with carbon graphite filling) 212F (100C) 150 psig (1136 kPa) 1/4 inch 396, 396P, 389 398 Viton or Kalrez
Code F Flange 20, 24, 27, 28
Code D Flow-through with Flanged Connection 20, 25, 26
Maximum Operating Temperature Maximum Operating Pressure Cleaning Port Connections Compatible pH Sensors
28
Wetted Materials (O-rings)
PASVE ROTARY RETRACTION VALVE (continued)
PASVE Valve, shown in welded on tank, manual operation configuration
FIGURE 20. PASVE Body Types
29
PASVE ROTARY RETRACTION VALVE (continued)
FIGURE 21. Operating PASVE Measuring Position
FIGURE 22. Operating PASVE Servicing and Calibration Position
FIGURE 23. PASVE Example of Flush Water Set-Up 30
PASVE ROTARY RETRACTION VALVE (continued)
FIGURE 24. PASVE pHC/P/F Recommended Flanged or Welded Mounting
31
PASVE ROTARY RETRACTION VALVE (continued)
FIGURE 25. Threaded and Flanged Connection to Process Flow PASVE pHT/D-(b) Manually Operated Dimensional Drawing.
FIGURE 26. Threaded and Flanged Connection to Process Flow PASVE pHT/D-(b) Pneumatic Operated Dimensional Drawing. 32
PASVE ROTARY RETRACTION VALVE (continued)
FIGURE 27. Flanged Process Connection PASVE pHC/P/F Pneumatic Operated Dimensional Drawing.
FIGURE 28. Flanged & Welded on Pipe or Tank PASVE pHC/P/F Manually Operated Dimensional Drawing. 33
PASVE ROTARY RETRACTION VALVE (continued)
ORDERING INFORMATION
The PASVE pH Rotary Retraction Valve is designed for safe, continuous measurement and on-line maintenance in tanks and pipelines to prolong sensor life, increase accuracy, and reduce maintenance requirements in harsh, coating applications, typically found in the pulp and paper industry. The valve operates via rotary motion to remove the electrode from the process for cleaning or storage and then rotates back to the sensing position when cleaning is completed. The sensor can also be safely removed from the valve under pressure, without process disruption or leakage for calibration and other routine maintenance.
MODEL PASVE pH Rotary Retraction Valve
CODE C B P FA FB DH2 DU2 CODE 0 1 CODE R10 R40 R60 CODE MD AD3 AE AS3 CODE 0IEO XIEO
MOUNTING METHODS Welded on tank Welded on tank with 15 angle Welded on pipe Flange mounted 3 ANSI, 150# Flange mounted 3 ANSI, 300# Flow through 1 ANSI 150# flanged connection Flow through 2 ANSI 150# flanged connection SEALS PTFE (Teflon) with graphite and carbon 100% PTFE (Teflon) ELECTRODE HOLDER TYPES Rosemount Analytical Model 389 Rosemount Analytical Model 396 Rosemount Analytical Model 396P ACTUATOR No actuator, for manual use only Double-action/solenoid 115 VAC 60 Hz Electric Actuator 115 VAC 60 Hz Spring-return/solenoid 115 VAC 60 Hz POSITION SWITCH None Standard
Notes: Consult factory for other materials of construction, such as titanium or Hastelloy C.
34
PASVE ROTARY RETRACTION VALVE (continued)
FIGURE 29. Operation of Manual Valve
PASVE and Model 54 in a pulp mill
Pneumatic PASVE mounted on a pipe
35
CHOOSING THE RIGHT MOUNTING SOLUTION FOR YOUR PROCESS NEEDS
The best way to choose the right mounting solution for your process is to do the following:
1) Locate a place to mount the sensor. Typical locations to mount a sensor are: a) small pipelines which mount the sensor in-line using pipe tees, the Quik-Loc Assembly, process connectors, or mounting adapters b) larger pipes where a ball valve kit or Pasve could be used for in-line mounting c) tanks, ponds, aeration basins, and open channels which could use a handrail mounting assembly (with or without the Jet Spray Cleaner) d) tanks using a ball valve kit or Quik-loc assembly e) in a low flow cell by tapping into an existing process with a 1/4" connection 2) Determine the process connection thread size that will mount the sensor. Typical process connection sizes are 3/4", 1", 1-1/2, and 2". 3) Determine the chemical compatibility of the sensor wetted materials to the process liquid components. In more aggressive chemicals, the sensor and mounting accessory wetted materials must be chosen carefully. Check the Chemical Resistance Chart or consult Rosemount Analytical Customer Support Center or Industry Specialists if there is a question about chemical compatibility - (800) 854-8257. 4) Choose the correct mounting accessory for your process. The guide below should help in understanding Rosemount Analytical's offerings of various sensor threads:
PROCESS END (FRONT END) THREADS, CLOSEST TO SENSING/MEASURING END OF THE SENSOR
CABLE END (BACK END) PROCESS THREADS, CLOSEST TO CABLE END OF THE SENSOR
FIGURE 31. TUpH Model 396P pH sensor is offered with 1 inch threads in two locations: one on the process end and one on the cable end.
Understanding sensor process connections:
Rosemount Analytical sensors are offered with wide variety of threaded process connections. The sensor shown above is TUpH Model 396P pH sensor. All sensors use similar terminology for process connection threads. Note that not all sensors are offered with front and back end threads for mounting the sen-
36
FIGURE 32. Model 228 Toroidal Conductivity Sensor (shown above) is offered with back end process threads only.
FIGURE 33. TUpH Model 396 pH sensor (shown above) is offered without process threads. A compression fit, process connector is used on the sensor body and gives the user flexibility for insertion depths because the process connector can be tightened in various locations on the sensor body. Retractable sensors (a longer version of what is shown above) are also offered without process threads. This is so the sensor can be mounted through a ball valve.
The sensors shown in Figures 32 and 33 are much different than the first sensor (396P) shown in Figure 31. Figure 32 is a Model 228 Toroidal sensor with 3/4" threads and is also offered with 5/8" UNC threads, both sizes an industry standard for conductivity sensor threads. Figure 33 is a Model 396 pH sensor and is not offered with any threads. The Model 396 is used with a process connector which allows variable insertion depths for the sensor and easy sensor removal without twisting the cable. The following pages contain a list of the sensors that are compatible with the mounting solutions listed in this brochure. The process thread sizes are also listed in the Sensor Compatibility Chart to aid with your choosing the correct mounting solution. Ordering Information: All sensors used with the accessories mentioned in this catalog must be purchased separately. Also, please note that additional accessory items must be purchased along with the stated mounting accessories in order for the complete mounting to be accomplished. Please consult your local representative for more information about sensors or consult the factory at 1-800-854-8257 (in the U.S.) or 1-949-757-8500 (outside of the U.S.). You can also visit the Rosemount Analytical, Uniloc Division, web site at http:\\www.RAuniloc.com .
37
SENSOR TO MOUNTING ACCESSORY COMPATIBILITY CHART
Description
Part Number
Compatible pH Sensors 396*, 396P, 389, 399, 385+* 396*, 396P, 389, 399, 385+* 396P, 389, 399 396P, 389, 399 396P, 389, 399 396*, 396P, 389, 399, 385+* 397 397 396*, 396P, 389, 399, 385+* 396*, 396P, 389, 399, 385+* 396*, 396P, 389, 399, 385+* 396*, 396P, 389, 399, 385+* 396R*, 398R*, 385, 385+
Compatible Conductivity Sensors
Compatible Dissolved Oxygen, Chlorine, & Ozone Sensors 499ADO, 499ACL 499AOZ
In-line Tee In-line Tee In-line Tee In-line Tee In-line Tee Low Flow Cell Quik-Loc Assembly Quik-Loc Assembly Handrail Mounting Jet Spray Cleaner Mounting Adapter Mounting Adapter Ball Valve Ball Valve Ball Valve Mechanical Valve Insertion Assembly Mechanical Valve Insertion Assembly Rotary Retraction Valve Process Connectors Process Connectors
23567-00 2002011 915240-03 915240-04 915240-05 23728-00 23757-00 23757-01 11275-01 12707-00 23242-02 23242-03 9330022 23240-00 23765-00 23765-01 23311-00 23311-01 See PASVE Ordering Matrix 23166-00 23166-01 9510066
150
499ADO, 499ACL 499AOZ 499ADO, 499ACL 499AOZ 499ADO, 499ACL 499AOZ 499ADO, 499ACL 499AOZ 499ADO, 499ACL 499AOZ
499ADO, 499ACL 499AOZ 499ADO, 499ACL 499AOZ 228
402-11, 402-12, 402-13 402-14 228 228 396, 396P, 389 396, 385+ 396, 385+
* Sensor process connector for connection to process must be purchased separately for first time installations.
38
COMPATIBLE SENSORS
Model Number 396 Threaded Process Connection Size None -to connect to process, order process connector PN 23166-00 or -01 Model Number Threaded Process Connection Size
385
Standard 1 inch process connector always shipped with sensor
396P
1 inch, front and back end threads
385+
None -to connect to process, order process connector PN 23166-00 or -01
396R and None 398R -mount sensor thru ball valve and use process connector PN 23166-00 or -01
397
None -must use Quik-Loc assembly (order separately)
389
1 inch, front and back end threads 328A None -for use with mounting assembly shown
399
1 inch, front and back end threads
150 499A CL 499A OZ 499A DO 1 inch, front and back end threads
1 inch, front and back end threads
402 228 3/4 inch NPT or 5/8 inch UNC, back end threads
None - mount sensor through ball valve
39
The right people, the right answers, right now.
ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE
http://www.raihome.com Specifications subject to change without notice.
Credit Cards for U.S. Purchases Only.
Emerson Process Management Liquid Division
2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com Rosemount Analytical Inc. 2006