Spor Lan
Spor Lan
P
O
R
L
A
N
R
E
F
.
&
A
/
C
P
R
O
D
U
C
T
S
Sporlan
Refrigeration and
Air Conditioning
Products
Oil Level Controls
Suction Filters Oil Filters
SeeAll
Head Pressure Control Valves
Solenoids
Three-Way Heat Reclaim Valves
TEV
Crankcase Pressure Regulating Valves
Catch-All
Discharge Bypass Valves
Evaporator Pressure Regulating Valves
SPORLAN REF. & A/C PRODUCTS
632
T
H
E
R
M
O
S
T
A
T
I
C
E
X
P
A
N
S
I
O
N
V
A
L
V
E
S
SPORLAN THERMOSTATIC EXPANSION VALVES
Selective Thermostat Charges Designed to provide optimum performance for all applications air conditioning
and heat pump, medium and Low temperature refrigeration.
Thermostatic Element Design Long lasting and field proven stainless steel diaphragm and welded element
construction.
Diaphragm Design Large flat diaphragm permits precise valve control.
Replaceable Thermostatic Elements Field replaceable elements on all standard valves.
Balanced Port Design Provides perfect pin and port alignment, and prevents changes in pressure drop across
the valve from influencing Valve operation. Provides excellent control on applications with widely varying operating
conditions.
Pin Carrier Design (Conventional Valves) Provides precise pin and port alignment, and tighter seating.
Accessible Internal Parts Durable, leak proof body joint construction allows the valve to be disassembled, and
the internal parts cleaned and inspected.
Materials of Construction Pin and port material offer maximum protection against corrosion and erosion.
Silver Soldered Connections For leak proof, high strength connection-to-body joints.
Adjustable Superheat Design All standard valves are externally adjustable.
VALVE NOMENCLATURE/ORDERING INSTRUCTIONS
Combine the letters and numbers in the following manner to obtain the complete valve designation. Also include all
connection Sizes and the capillary tube length.
CONVENTIONAL VALVES:
S V E - 8 - GA
5/8ODF
Solder
X
7/8ODF
Solder
X
1/4 ODF
Solder
X 5
Sporlan Code - REFRIGERANT -
Element Label Color Code
Body
Type:
FB,F,
EF,G,
EG,
RI,RC,
S,
EBS*,
O*,
V**,
W**
F - R-12 Yellow
E - R-13 - Blue
V - R-22 -Green
G - R-23 - Blue
M - R124 - Blue
J- R134a -Blue
X - R-401A Pink
L - R-402ASand
S- R-404A Orange
V - R-407A Green
N - R-407 Lt. Brown
S - R-408A -Purple
F - R-409A -Yellow
R - R-502 - Purple
W - R-503 - Blue
P - R-507 - Teal
W - R-508B - Blue
A - R-717 White
E specifies
external
equalizer.
Omission of
letter E
indicates
valve with
internal
equalizer.
e.g.
EGV-1-C
Nominal
Capacity
in Tons
Thermostatic
Charge
Inlet
Connection
Size
and
Style
Outlet
Connection
Size
and
Style
External
Equalizer
Connection
Size
and
Style
Capillary
Tubing
Length
(Inches
or Feet)
BALANCE PORTED VALVES:
EBF
V
E
-
AA
-
C
3/8
Extended
ODF Solder
X
1/2
Extended
ODF Solder
X
1/4
Extended
ODF Solder
X
30
Port
Size
Nominal
Capacity
in Tons
AAA 1/8 thru 1/3
AA 1/2 thru 2/3
A 3/4 thru 1-1/2
B 1-3/4 thru 3
22 (V)
407C (N)
407A (V)
C 3-1/4 thru 5-1/2
AAA 1/8 thru 1/5
AA 1/4 thru 1/3
A 1/2 thru 1
B 1-1/4 thru 1-3/4
134a (J)
12 (F)
401A (X)
409A (F)
C 2 thru 3
AAA 1/8 thru 1/5
AA 1/4 thru 1/3
A 1/2 thru 1
B 1-1/4 thru 2
404A (S)
502 (R)
408A (S)
C 2-1/4 thru 3
AAA 1/8 thru 1/5
AA 1/4 thru 1/3
A 1/2 thru 1
B 1-1/4 thru 2
Body
Type:
BF,SBF,
EBF
507 (P)
402A (L)
E specifies
external
equalizer.
Omission of
letter E
indicates
valve
with internal
equalizer.
C 2-1/4 thru 3
Thermostatic
Charge
Inlet
Connection
Size
and
Style
Outlet
Connection
Size
and
Style
External
Equalizer
Connection
Size
and
Style
Capillary
Tubing
Length
(Inches)
*EBS and O valves are balance ported valves, but follow conventional valve nomenclature.
**V and W valves have dual port semi-balance design.
THERMOSTATIC EXPANSION VALVES
633
T
H
E
R
M
O
S
T
A
T
I
C
E
X
P
A
N
S
I
O
N
V
A
L
V
E
S
SPORLAN SELECTIVE CHARGES ENGINEERED FOR PEAK PERFORMANCE FOR EACH SPECIFIC
APPLICATION
RECOMMENDED THERMOSTATIC CHARGES*
REFRIGERANT
APPLICATION
12
409A
22
407A
134a
401A
402A
404A
408A
407C
502
507
717
ACTUAL
THERMOSTATIC
CHARGES
FCP60 JCP60 XCP60 FCP60
VCP100 NCP100 VCP100
VGA NGA VGA
AIR CONDITIONING
SCP115 RCP115 SCP115
FC JC XC FC
VC NC VC
SC RC SC
LC PC PC
COMMERCIAL
REFRIGERATION 50F
TO -10F
AC, AL AC, AL
FZ FZ
FZP FZP
VZ VZ
VZP40 VZP40
LZ SZ RZ PZ SZ
LZP SZP RZP PZP SZP
LOW TEMPERATURE
REFRIGERATION 0F
TO -40F
AZ, AL AZ, AL
VX VX EXTREME LOW
TEMP.REFRIGERATION
-40F TO -100F LX SX RX PX SX
* APPLICATION FACTORS:
1. The Type ZP charges have essentially the same characteristics as the Type Z charge with one exception: they produce a
pressure limit Maximum Operating Pressure (MOP). ZP charges are not intended as replacements for Z charges. Each
should be selected for its own unique purpose.
2. All air conditioning and heat pump charges are intended for use with externally equalized valves.
3. Type L liquid charges are also available for most commonly used refrigerants in most element sizes.
4. If in doubt as to which charge to use, contact Sporlan Valve Company, Washington, Missouri with complete system data.
5. The Type X charges are not to be used with EBS and O valves.
IMPORTANT NOTES:
A. R-134a air conditioning and commercial refrigeration applications are using R-12 or R-409A or
R-401A valves.
B. R-404A commercial refrigeration applications are using R-502 or R-408A valves.
C. R-404A and R-507 low temperature refrigeration applications are using R-502 or R-402A or
R-408A valves.
THERMOSTATIC EXPANSION VALVES
634
T
H
E
R
M
O
S
T
A
T
I
C
E
X
P
A
N
S
I
O
N
V
A
L
V
E
S
QUICK REFERENCE GUIDE REFRIGERATION VALVES
NOMINAL CAPACITY
RANGE (Tons) VALUE
TYPE
R-22
R-134a
R-404A
&
R-507
CONNECTION
TYPES
VALVE DESCRIPTION AND APPLICATION
F
1/5
thru
3
1/8
thru
2
1/8
thru
2
SAE Flare
Small brass bar body, externally adjustable valve for
small capacity refrigeration systems. SAE flare inlet
connection has a removable 100 mesh strainer. Typical
applications: Refrigerated cases, coolers, freezers.
EF
1/5
thru
3
1/8
thru
2
1/8
thru
2
ODF Solder
Same as the Type F valve except it features ODF
solder connections. The inlet connection has a 50
mesh strainer. Typical applications: Refrigerated
cases, coolers, freezers.
G
1/5
thru
3
1/8
thru
2
1/8
thru
2
SAE Flare
Forged brass bar body, externally adjustable valve for
small capacity refrigeration systems. Inlet connection
has a removable 100 mesh strainer. Typical
applications: Refrigerated cases, coolers, freezers and
small capacity air conditioners.
EG
1/5
thru
3
1/8
thru
2
1/8
thru
2
ODF Solder
Same as the Type G valve except it features ODF
solder connections and a forged brass inlet fitting with
a removable 100 mesh strainer which can be cleaned
and/or replaced without moving the valve from the line.
FB
1/4
thru
8
1/4
thru
5
1/4
thru
6
SAE Flare
or
ODF Solder
Small brass body valve available only with straight
through connections and external adjustment. Typical
applications: Small capacity air conditioning and
refrigeration applications where an external adjustment
is desired
BF
1/3
thru
5
1/4
thru
3
1/4
thru
3
SAE Flare
Same physical size as the Type F valve with SAE flare
connection except it features a balanced port
construction. Inlet connection has removable 100 mesh
strainer. Typical applications: Small capacity refrigeration
that operates over widely varying operating conditions.
SBF
1/3
thru
5
1/4
thru
3
1/4
thru
3
Extended
ODF Solder
Same as the Type BF valve except it features ODF
solder connection and a forged brass inlet fitting with a
removable 100 mesh strainer which can be cleaned
and/or replaced without removing the valve from
the line.
EBF
1/3
thru
5
1/4
thru
3
1/4
thru
3
Extended
ODF Solder
Same as the Type BF valve except it features ODF
solder connections.
S
2
thru
10
2
thru
6
2
thru
7
ODF Solder
Brass bar body, externally adjustable valve. General
purpose valve for air conditioning and refrigeration
applications.
EMC
0.64
thru
2.34
0.46
thru
1.69
0.42
thru
1.51
ODF Solder
Multi-capacity two part valve designed to perform
effectively over the range of load conditions inherent
with most refrigeration systems. Large port is for pull
down load and smaller port to control holding loads.
THERMOSTATIC EXPANSION VALVES
635
T
H
E
R
M
O
S
T
A
T
I
C
E
X
P
A
N
S
I
O
N
V
A
L
V
E
S
PART
NO*
SPORLAN MODEL**
PART
NO*
SPORLAN MODEL**
PART
NO*
SPORLAN MODEL**
TYPE F
TYPE BF
TYPE FB
FF-1-1/2-C 3X4 SAE 30"
BFF-A-C 3X4 SAE 30"
FBS-1/4-C 3SX4 ODF 30"
FF-1-C 3X4 SAE 30"
BFJE-A-C 3X4 SAE 30"
FBS-1/4-Z 2SX4 ODF 30"
FFE-1-C 3X4 SAE 30"
BFJE-B-C 3X4 SAE 30"
FBS-1/4-ZP 3SX4 ODF 30"
FFE-2-C 3X4 SAE 30"
BFR-A-C 3X4 SAE 30"
FBSE-1/2-C 3SX4X2 ODF 30"
FJ-1/2-C 2X4 SAE 30"
BFRE-A-Z 3X4 SAE 30"
FBSE-1/4-C 3SX4X2 ODF 30"
FJ-1/4-C 2X4 SAE 30"
BFRE-A-ZP 3X4 SAE 30"
FBSE-1/4-ZP 3SX4X2 ODF 30"
FJ-1/4-Z 2X4 SAE 30"
BFRE-B-C 3X4 SAE 30"
FBSE-1\2-ZP 3SX4 ODF 30"
FR-1/4-Z 2X4 SAE 30"
BFRE-B-Z 3X4 SAE 60"
FBSE-1-1\2-C 3SX4 ODF 30"
FRE-1/2-C 3X4 SAE 30"
BFRE-B-ZP 3X4 SAE 30"
FBSE-1-1\2-ZP 3SX4 ODF 30"
FRE-1/2-Z 3X4 SAE 30"
BFSE-AA-ZP 3X4 SAE 30"
FBSE-1-C 3SX4 ODF 30"
FRE-1/2-ZP 3X4 SAE 30"
BFSE-A-C 3X4 SAE 30"
FBSE-1-Z 3X4X2 ODF 30"
FRE-1/4-Z 2X4 SAE 30"
BFSE-C-ZP 3X4 SAE 30"
FBSE-1-ZP 3SX4 ODF 30"
FRE-1-1/2-C 3X4 SAE 30"
BFV-AA-C 3X4 SAE 30"
FBSE-2-C 3SX4X2 ODF 30"
FRE-1-1/2-Z 3X4 SAE 30"
BFV-A-C 3X4 SAE 30"
FBSE-2-Z 3X4X2 ODF 30"
FRE-1-1/2-ZP35 2X4 SAE 30"
BFVE-AAA-C 3X4 SAE 30"
FBSE-2-ZP 3SX4X2 ODF 30"
FRE-1-ZP 3X4 SAE 30"
BFVE-AA-C 3X4 SAE 30"
FBSE-3.5-C 4X7X2 ODF 60"
FRE-2-Z 3X4 SAE 30"
BFVE-A-C 3X4 SAE 30"
FBSE-3.5-ZP 4X7X2 ODF 30"
FRE-2-ZP 3X4 SAE 30"
BFVE-B-C 3X4 SAE 30"
FBSE-3-C 4X7X2 ODF 60"
FS-1/2-C 2X4 SAE 30"
FBSE-3-ZP 4X7X2 ODF 30"
FS-1/4-C 2X4 SAE 30"
FBSE-4.5-C 4X7X2 ODF 60"
FS-1/4-ZP 2X4 SAE 30"
FBSE-4.5-ZP 4X7X2 ODF 30"
FSE-1/2-Z 2X4 SAE 30"
FBSE-6-C 5X7X2 ODF 60"
FSE-1/2-ZP35 2X4 SAE 30"
FBSE-6-ZP 5X7X2 ODF 30"
FSE-1/4-ZP 2X4 SAE 30"
FBV-1/4-C 2*SX4 ODF 30"
FSE-1/4-ZP30 2X4 SAE 30"
TYPE G
FBV-1/4-C 3*SX4 ODF 30"
FSE-1-C 3X4 SAE 30"
GRE-1-1/2-ZP 3X4 SAE 5'
FBV-1/4-ZP40 3SX4 ODF 30"
FV-1/4-C 2X4 SAE 30"
GRE-1-ZP 3X4 SAE 5'
FBVE-1/2-ZP40 3*SX4X2 ODF 30"
FVE-1/2-C 3X4 SAE 30"
GVE-1-C 3X4 SAE 5'
FBVE-1/4-C 3*SX4X2 ODF 30"
FVE-1/4-C 2X4 SAE 30"
GVE-3/4-C 3X4 SAE 5'
FBVE-1/4-ZP40 3*SX4X2 ODF 30"
FVE-1-1/2-C 3X4 SAE 30"
GVE-3/4-ZP 3X4 SAE 5'
FBVE-1\2-C 3*SX4 ODF 30"
FVE-1-C 3X4 SAE 30"
GVE-3-C 3X4 SAE 5'
FBVE-1-1/2-ZP40 3*SX4X2 ODF 30"
FVE-2-C 3X4 SAE 30"
FBVE-1-1\2-C 3*SX4 ODF 30"
FVE-3-C 3X4 SAE 30"
FBVE-1-C 3*SX4 ODF 30"
FBVE-1-ZP40 3*SX4X2 ODF 30"
FBVE-2.5-C 4X5X2 ODF 60"
FBVE-2.5-ZP40 4X5X2 ODF 30"
TYPE FB
FBVE-2-C 4X5X2 ODF 30"
FBFE-1-C 3SX4X2 ODF 30"
FBVE-2-ZP40 4X5X2 ODF 30"
TYPE EF
FBJE-1/2-CP60 3X4X2 ODF 30"
FBVE-3-C 4X5X2 ODF 60"
EFF-1/4-Z 2SX3 ODF 30"
FBJE-1/2-Z 3X4X2 ODF 30"
FBVE-3-ZP40 4X5X2 ODF 60"
EFJ-1/2-C 2SX3 ODF 30"
FBR-1/2-Z 2X4 SAE 30"
FBVE-4-C 4X7X2 ODF 60"
EFJ-1/4-C 2SX4 ODF 30"
FBR-1/4-Z 2X4 SAE 30"
FBVE-4-ZP40 4X7X2 ODF 60"
EFS-1/4-C 2SX3 ODF 30"
FBS-1/2-C 3SX4 ODF 30"
FBVE-5-C 4X7X2 ODF 60"
EFS-1/4-Z 2SX3 ODF 30"
FBS-1/2-Z 2SX4 ODF 30"
FBVE-5-ZP40 4X7X2 ODF 60"
EFS-1-Z 3X4 ODF 30"
FBS-1/2-ZP 3SX4 ODF 30"
FBVE-6-C 4X7X2 ODF 60"
EFSE-1/2-Z 3X4 ODF 30"
FBVE-6-GA 4X5X2 ODF 30"
EFSE-1/4-Z 3X4 ODF 30"
FBVE-6-ZP40 4X7X2 ODF 60"
EFSE-1/6-Z 2X4 ODF 30"
FBVE-8-C 5X7X2 ODF 60"
EFVE-1/2-C 3X4 ODF 30"
FBVE-8-ZP40 5X7X2 ODF 60"
EFVE-1/2-L1 3X4 ODF 30"
EFVE-1/3-C 2X4 ODF 30"
EFVE-1/3-C 3X4 ODF 30"
EFVE-1/3-L1 3X4 ODF 30"
EFVE-1/5-C 2X4 ODF 30"
EFVE-1-C 3X4 ODF 30"
IMPORTANT NOTE:
00*S - with Insert Strainer
Connection Sizes are in eighths of
inch (3x4 means 3/8 inlet x 1/2
outlet).
*( ) Please contact your local Carlyle Certified Refrigeration Partner or RCD Customer Service Center for part number and pricing.
THERMOSTATIC EXPANSION VALVES
636
T
H
E
R
M
O
S
T
A
T
I
C
E
X
P
A
N
S
I
O
N
V
A
L
V
E
S
PART
NO*
SPORLAN MODEL** PART
NO*
SPORLAN MODEL** PART
NO*
SPORLAN MODEL** PART
NO*
SPORLAN MODEL**
EGV-1/2-ZP40 3X4 ODF 5'
SBFP-AAA-Z 3X4 ODF 30"
EGV-1/3-C 3X4 ODF 5'
SBFP-AA-C 3X4 ODF 30"
EGV-1/3-Z 3X4 ODF 5'
SBFP-AA-Z 3X4 ODF 30"
EGV-1/5-C 3X4 ODF 5'
SBFP-A-C 3X4 ODF 30"
EGV-1/5-Z 3X4 ODF 5'
SBFP-B-C 3X4 ODF 30"
EGV-1-C 3X4 ODF 5'
SBFPE-AAA-C 3X4 ODF 30"
TYPE EG
EGV-3/4-C 3X4 ODF 5'
SBFPE-AA-C 3X4 ODF 30"
TYPE EBF
EGFE-1/2-C 3X4 ODF 5'
EGV-3/4-Z 3X4 ODF 5'
SBFPE-AA-Z 3X4 ODF 30"
EBFF-AAA-C 3X4 ODF 30"
EGFE-1/4-C 3X4 ODF 5'
EGV-3/4-ZP 3X4 ODF 5'
SBFPE-B-C 3X4 ODF 30"
EBFF-A-C 3X4 ODF 30"
EGFE-1-C 3X4 ODF 5'
EGV-3/4-ZP40 3X4 ODF 5'
SBFPE-C-C 3X4 ODF 30"
EBFFE-A-C 3VX4 ODF 30"
EGFE-2-C 3X4 ODF 5'
EGVE-1/2-C 3X4 ODF 5'
SBFR-AAA-Z 3X4 ODF 30"
EBFFE-B-C 3X4 ODF 30"
EGJ-1/4-C 3X4 ODF 5'
EGVE-1/2-L1 3X4 ODF 5'
SBFR-AAA-ZP 3X4 ODF 30"
EBFLE-A-C 3X4 ODF 30"
EGJ-1/6-C 3X4 ODF 5'
EGVE-1/2-Z 3X4 ODF 5'
SBFR-AA-C 3X4 ODF 30"
EBFLE-A-Z 3X4 ODF 30"
EGJ-1/8-C 3X4 ODF 5'
EGVE-1/2-ZP40 3X4 ODF 5'
SBFR-AA-Z 3X4 ODF 30"
EBFPE-C-C 3X4 ODF 30"
EGJE-1/6-C 3X4 ODF 5'
EGVE-1/3-C 3X4 ODF 5'
SBFR-AA-ZP 3X4 ODF 30"
EBFPE-C-Z 3X4 ODF 30"
EGJE-1/8-C 3X4 ODF 5'
EGVE-1/5-C 3X4 ODF 5'
SBFR-A-C 3X4 ODF 30"
EBFR-A-C 3EX4 ODF 30"
EGJE-1-1/2-C 3X4 ODF 5'
EGVE-1-1/2-C 3X4 ODF 5'
SBFR-A-ZP 3X4 ODF 30"
EBFRE-AA-Z 3VX4 ODF 30"
EGP-1/2-C 3X4 ODF 5'
EGVE-1-1/2-Z 3X4 ODF 5'
SBFR-B-C 3X4 ODF 30"
EBFRE-AA-ZP 3VX4 ODF 30"
EGP-1/4-C 3X4 ODF 5'
EGVE-1-1/2-ZP40 3X4 ODF 5'
SBFRE-AAA-C 3X4 ODF 30"
EBFRE-A-Z 3EX4 ODF 30"
EGP-1/6-C 3X4 ODF 5'
EGVE-1-C 3X4 ODF 5'
SBFRE-AAA-Z 3X4 ODF 30"
EBFRE-A-Z 3X4 ODF 30"
EGP-1/8-C 3X4 ODF 5'
EGVE-1-Z 3X4 ODF 5'
SBFRE-AA-Z 3X4 ODF 30"
EBFRE-A-ZP 3EX4 ODF 30"
EGPE-1/2-C 3X4 ODF 5'
EGVE-1-ZP40 3X4 ODF 5'
SBFRE-A-Z 3X4 ODF 30"
EBFS-AAA-ZP 2X4 ODF 30"
EGPE-1/4-C 3X4 ODF 5'
EGVE-2-C 3X4 ODF 5'
SBFRE-B-Z 3X4 ODF 30"
EBFSE-AAA-Z 2SX4 ODF 30"
EGPE-1/8-C 3X4 ODF 5'
EGVE-2-Z 3X4 ODF 5'
SBFS-AAA-C 3X4 ODF 30"
EBFSE-AAA-ZP 3VX4 ODF 30"
EGPE-1-1/2-C 3X4 ODF 5'
EGVE-2-ZP40 3X4 ODF 5'
SBFSE-AAA-ZP 3X4 ODF 30"
EBFSE-AA-C 3X4 ODF 30"
EGPE-1-C 3X4 ODF 5'
EGVE-3/4-C 3X4 ODF 5'
SBFSE-AA-C 3X4 ODF 30"
EBFSE-A-C 3VX4 ODF 30"
EGPE-2-C 3X4 ODF 5'
EGVE-3/4-L1 3X4 ODF 5'
SBFSE-AA-ZP 3X4 ODF 30"
EBFSE-A-Z 3VX4 ODF 30"
EGR-1/2-C 3X4 ODF 5'
EGVE-3/4-X 3X4 ODF 5'
SBFSE-A-C 3X4 ODF 30"
EBFSE-B-C 3VX4 ODF 30"
EGR-1/2-Z 3X4 ODF 5'
EGVE-3/4-Z 3X4 ODF 5'
SBFSE-A-ZP 3X4 ODF 30"
EBFSE-B-Z 3VX4 ODF 30"
EGR-1/2-ZP 3X4 ODF 5'
EGVE-3/4-ZP 3X4 ODF 5'
SBFSE-B-C 3X4 ODF 30"
EBFSE-B-ZP 3X4 ODF 30"
EGR-1/4-C 3X4 ODF 5'
EGVE-3/4-ZP40 3X4 ODF 5'
SBFSE-B-Z 3X4 ODF 30"
EBFSE-C-C 3X4 ODF 30"
EGR-1/4-Z 3X4 ODF 5'
EGVE-3-C 3X4 ODF 5'
SBFSE-B-ZP 3X4 ODF 30"
EBFSE-C-Z 3X4 ODF 30"
EGR-1/6-C 3X4 ODF 5'
EGVE-3-Z 3X4 ODF 5'
SBFSE-C-C 3X4 ODF 30"
EBFSE-C-ZP 3VX4 ODF 30"
EGR-1/8-C 3X4 ODF 5'
EGVE-3-ZP40 3X4 ODF 5'
SBFSE-C-Z 3X4 ODF 30"
EBFV-AAA-C 3EX4 ODF 30"
EGR-1/8-Z 3X4 ODF 5'
EGX-1/2-C 3X4 ODF 5'
SBFSE-C-ZP 3X4 ODF 30"
EBFV-AA-C 3EX4 ODF 30"
EGR-1-C 3X4 ODF 5'
SBFV-AAA-C 3X4 ODF 30"
EBFV-AA-Z 3EX4 ODF 30"
EGRE-1/4-Z 3X4 ODF 5'
SBFV-AAA-Z 3X4 ODF 30"
EBFV-AA-ZP40 3EX4 ODF 30"
EGRE-1/6-C 3X4 ODF 5'
SBFV-AA-C 3X4 ODF 30"
EBFV-A-C 3EX4 ODF 30"
EGRE-1/8-C 3X4 ODF 5'
SBFV-AA-Z 3X4 ODF 30"
EBFV-B-C 3X4 ODF 30"
EGRE-1-ZP40 3X4 ODF 5'
SBFV-AA-ZP40 3X4 ODF 30"
EBFVE-AAA-C 3X4 ODF 30"
EGRE-2-C 3X4 ODF 5'
TYPE SBF
SBFV-A-C 3X4 ODF 30" EBFVE-AA-C 3EX4 ODF 30"
EGRE-2-Z 3X4 ODF 5'
SBFF-AA-ZP 3X4 ODF 30"
SBFV-B-C 3X4 ODF 30"
EBFVE-AA-CP100 3VX4 ODF 30"
EGSE-1/2-C 3X4 ODF 5'
SBFF-A-ZP 3X4 ODF 30"
SBFVE-AAA-C 3X4 ODF 30"
EBFVE-AA-Z 3EX4 ODF 30"
EGSE-1/2-Z 3X4 ODF 5'
SBFFE-AA-ZP 3X4 ODF 30"
SBFVE-AAA-ZP40 3X4 ODF 30"
EBFVE-AA-ZP40 3EX4 ODF 30"
EGSE-1/2-ZP 3X4 ODF 5'
SBFFE-A-ZP 3X4 ODF 30"
SBFVE-AA-C 3X4 ODF 30"
EBFVE-A-C 3EX4 ODF 30"
EGSE-1/4-C 3X4 ODF 5'
SBFFE-B-ZP 3X4 ODF 30"
SBFVE-AA-Z 3X4 ODF 30"
EBFVE-A-Z 3X4 ODF 30"
EGSE-1/4-ZP 3X4 ODF 5'
SBFJ-AAA-C 3X4 ODF 30"
SBFVE-AA-ZP40 3X4 ODF 30"
EBFVE-A-ZP40 3VX4 ODF 30"
EGSE-1-1/2-C 3X4 ODF 5'
SBFJ-AA-C 3X4 ODF 30"
SBFVE-A-C 3X4 ODF 30"
EBFVE-B-C 3X4 ODF 30"
EGSE-1-1/2-Z 3X4 ODF 5'
SBFJ-A-C 3X4 ODF 30"
SBFVE-A-Z 3X4 ODF 30"
EBFVE-B-CP100 3X4 ODF 30"
EGSE-1-1/2-ZP 3X4 ODF 5'
SBFJ-B-C 3X4 ODF 30"
SBFVE-A-ZP 3X4 ODF 30"
EBFVE-B-Z 3X4 ODF 30"
EGSE-1-C 3X4 ODF 5'
SBFJE-AAA-C 3X4 ODF 30"
SBFVE-A-ZP40 3X4 ODF 30"
EBFVE-B-ZP40 3X4 ODF 30"
EGSE-1-X 3X4 ODF 5'
SBFJE-AA-C 3X4 ODF 30"
SBFVE-B-C 3X4 ODF 30"
EBFVE-C-C 3X4 ODF 30"
EGSE-1-Z 3X4 ODF 5'
SBFJE-A-C 3X4 ODF 30"
SBFVE-B-Z 3X4 ODF 30"
EBFVE-C-CP100 3X4 ODF 30"
EGSE-1-ZP 3X4 ODF 5'
SBFJE-B-C 3X4 ODF 30"
SBFVE-B-ZP40 3X4 ODF 30"
EBFVE-C-ZP40 3VX4 ODF 30"
EGSE-2-C 3X4 ODF 5'
SBFJE-C-C 3X4 ODF 30"
SBFVE-C-C 3X4 ODF 30"
EGSE-2-ZP 3X4 ODF 5'
SBFP-AAA-C 3X4 ODF 30"
SBFVE-C-Z 3X4 ODF 60"
EGV-1/2-C 3X4 ODF 5'
SBFVE-C-ZP40 3X4 ODF 30"
EGV-1/2-Z 3X4 ODF 5'
IMPORTANT NOTES:
E Elbow Inlet
V 877 Series (100 Mesh) Strainer
*( ) Please contact your local Carlyle Certified Refrigeration Partner or RCD Customer Service Center for part number and pricing.
THERMOSTATIC EXPANSION VALVES
637
T
H
E
R
M
O
S
T
A
T
I
C
E
X
P
A
N
S
I
O
N
V
A
L
V
E
S
PART
NO*
SPORLAN MODEL** PART
NO*
SPORLAN MODEL** PART
NO*
SPORLAN MODEL**
TYPE KT
KT-43-FC 5(1.5M) ELEMENT
KT-43-FZ 5(1.5M) ELEMENT
KT-43-FZP 5(1.5M) ELEMENT
KT-43-PC 5 ELEMENT
KT-43-RC 5(1.5M) ELEMENT
KT-43-RZ 30"(.75M) ELEMENT
TYPE S
TYPE EMC
KT-43-RZP 5(1.5M) ELEMENT
SRE-1/2-C 4X5 ODF 5'
EMC-10-PC 3X4 ODF 5'
KT-43-VC 5(1.5M) ELEMENT
SRE-1/2-ZP 4X5 ODF 5'
EMC-10-SC 3X4 ODF 5'
KT-43-VZ 5(1.5M) ELEMENT
SRE-1-1/2-C 4X5 ODF 5'
EMC-10-SZ 3X4 ODF 5'
KT-43-VZP 5(1.5M) ELEMENT
SRE-1-1/2-Z 4X5 ODF 5'
EMC-10-VC 3X4 ODF 5'
KT-53-FC 5 ELEMENT
SRE-1-1/2-ZP 4X5 ODF 5'
EMC-10-VZ 3X4 ODF 5'
KT-53-FZ 5(1.5M) ELEMENT
SRE-1-C 4X5 ODF 5'
EMC-11-SZ 3X4 ODF 5'
KT-53-FZP 5(1.5M) ELEMENT
SRE-1-ZP 4X5 ODF 5'
EMC-20-PC 3X4 ODF 5'
KT-53-RC 5 ELEMENT
SRE-2-L1 4X5 ODF 5'
EMC-20-SC 3X4 ODF 5'
KT-53-SZ 5 ELEMENT
SRE-4-Z 4X7 ODF 5'
EMC-20-VC 3X4 ODF 5'
KT-53-SZP 5 ELEMENT
SSE-1/4-C 3X4 ODF 5'
EMC-21-PC 3X4 ODF 5'
KT-53-VC 5 ELEMENT
SSE-10-ZP 5X7 ODF 5'
EMC-21-SC 3X4 ODF 5'
KT-53-VZ 5(1.5M) ELEMENT
SSE-10-ZP 7X9 ODF 5'
EMC-21-VC 3X4 ODF 5'
KT-53-VZP 5(1.5M) ELEMENT
SSE-2-C 4X5 ODF 5'
EMCE-10-JC 3X4 ODF 5'
KT-83-FC 5 ELEMENT
SSE-2-ZP 4X5 ODF 5'
EMCE-10-PC 3X4 ODF 5'
KT-83-SC 5 ELEMENT
SSE-3-C 4X7 ODF 5'
EMCE-10-SC 3X4 ODF 5'
KT-83-SZ 5 ELEMENT
SSE-3-L1 4X7 ODF 5'
EMCE-10-SZ 3X4 ODF 5'
KT-83-SZP ELEMENT
SSE-3-ZP 4X7 ODF 5'
EMCE-10-VC 3X4 ODF 5'
KT-83-VC 5 ELEMENT
SSE-3-ZP40 4X7 ODF 5'
EMCE-10-VZ 3X4 ODF 5'
KT-45-ZGA, 30" ELEMENT
SSE-4-C 4X7 ODF 5'
EMCE-11-SZ 3X4 ODF 5'
SSE-4-ZP 4X7 ODF 5'
EMCE-11-VZ 3X4 ODF 5'
SSE-6-C 4X7 ODF 5'
EMCE-12-SC 3X4 ODF 5'
SSE-6-C 5X7 ODF 5'
EMCE-12-SZ 3X4 ODF 5'
SSE-6-X 5X7 ODF 5'
EMCE-12-VC 3X4 ODF 5'
SSE-6-Z 5X7 ODF 5'
EMCE-12-VZ 3X4 ODF 5'
SSE-6-ZP 5X7 ODF 5'
EMCE-13-SZ 3X4 ODF 5'
SSE-7-C 5X7 ODF 5'
EMCE-13-VZ 3X4 ODF 5'
SSE-7-ZP 5X7 ODF 5'
EMCE-20-JC 3X4 ODF 5'
SVE-1/2-C 4X5 ODF 5'
EMCE-20-PC 3X4 ODF 5'
SVE-10-C 5X7 ODF 5'
EMCE-20-SC 3X4 ODF 5'
SVE-1-1/2-C 4X5 ODF 5'
EMCE-20-VC 3X4 ODF 5'
SVE-1-1/2-L1 3X4 ODF 5'
EMCE-21-JC 3X4 ODF 5'
SVE-1-1/2-Z 3X4 ODF 5'
EMCE-21-PC 3X4 ODF 5'
SVE-1-1/2-ZP40 4X5 ODF 5'
EMCE-21-SC 3X4 ODF 5'
SVE-15-C 7X11 ODF 5'
EMCE-21-VC 3X4 ODF 5'
SVE-15-CP100 7X9 ODF 5'
EMCE-22-JC 3X4 ODF 5'
SVE-1-C 4X5 ODF 5'
EMCE-22-PC 3X4 ODF 5'
SVE-1-ZP40 4X5 ODF 5'
EMCE-22-SC 3X4 ODF 5'
SVE-2-C 4X5 ODF 5'
EMCE-22-VC 3X4 ODF 5'
SVE-2-L1 4X5 ODF 5'
EMCE-23-PC 3X4 ODF 5'
SVE-2-ZP40 4X5 ODF 5'
EMCE-23-SC 3X4 ODF 5'
SVE-3-C 4X5 ODF 5'
EMCE-23-VC 3X4 ODF 5'
SVE-3-L1 4X5 ODF 5'
SVE-3-L2 4X5 ODF 5'
SVE-3-ZP40 4X5 ODF 5'
SVE-4-C 4X7 ODF 5'
SVE-4-L1 4X7 ODF 5'
SVE-4-X 4X7 ODF 5'
SVE-4-ZP40 4X7 ODF 5'
SVE-5-C 4X7 ODF 5'
SVE-8-C 5X7 ODF 5'
SVE-8-L1 5X7 ODF 5'
SVE-8-Z 5X7 ODF 5'
IMPORTANT NOTES:
A. R-134a air conditioning and
commercial refrigeration
applications are using R-12 or
R-409A or R-401A elements.
B. R-404A commercial refrigeration
applications are using R-502 or
R-408A elements.
C. R-404A and R-507 low temperature
refrigeration applications are using
R-502 or R-402A or R-408A elements.
*( ) Please contact your local Carlyle Certified Refrigeration Partner or RCD Customer Service Center for part number and pricing.
THERMOSTATIC EXPANSION VALVES
638
T
H
E
R
M
O
S
T
A
T
I
C
E
X
P
A
N
S
I
O
N
V
A
L
V
E
S
SPORLAN THERMOSTATIC EXPANSION VALVES
QUICK REFERENCE GUIDE AIR CONDITIONING VALVES
NOMINAL CAPACITY RANGE (Tons)
VALVE TYPE
R-22
R-134a
R-404A &
R-507
CONNECTION
TYPES
VALVE DESCRIPTION AND APPLICATION
2 thru 6
ODF Solder
Compact and adjustable thermostatic expansion valve
with an internal check valve to allow reverse flow on
heat pump applications. Valve also can be used for
refrigerant 410A applications.(2 ton through 6 ton) RC
valve replaces RI valve.
2 thru 10
2 thru 6
2 thru 7
ODF Solder
Brass bar body, externally adjustable valve. Inlet has a
permanent 12 mesh strainer. General purpose valve for
air conditioning and refrigeration applications.
8 & 11
5 & 7
6 & 7-1/2
Extended ODF
Solder
Same physical size as the Type S valve except it
features extended ODF connections and a balanced
port construction.
15 thru 70
9 thru 40
9 thru 45
ODF Solder
Brass bar body, externally adjustable valve. Inlet has a
permanent 12 mesh strainer. General purpose valve for
air conditioning and refrigeration applications.
52 thru 100
35 thru 55
38 thru 70
ODF Solder or
FPT Flange
Cast bronze body, externally adjustable valve with
flange connections. Inlet has a 12 mesh strainer. This
valve type features a dual port semi-balanced design.
This valve type provides valve capacities greater than
the Type M, and is suitable for air conditioning and
refrigeration applications. Flanges for the Type V are
interchangeable with the Type M.
135 & 180
80 & 110
ODF Solder
Flange
Cast bronze body, externally adjustable valve with
flange connections. Inlet has a 12 mesh strainer. This
valve type features a dual port semi-balanced design
and it is primarily for large capacity chillers. This valve
type provides the largest valve capacities available for
flange connection TEVs.
R-22 M Valves With GA & CP 100 Thermostatic chargers are also available
THERMOSTATIC EXPANSION VALVES
639
T
H
E
R
M
O
S
T
A
T
I
C
E
X
P
A
N
S
I
O
N
V
A
L
V
E
S
SPORLAN THERMOSTATIC EXPANSION
VALVES
Type-S
ELEMENT SIZE No. 83, Knife Edge
Joint. Standard Tubing Length 5 Feet.
STANDARD
CONNECTIONS
(in. ODF Solder)
REFRIGERANT
(Sporlan Code)
TYPE &
CAPACITY
T
H
E
R
M
O
S
T
A
T
I
C
C
H
A
R
G
E
S
A
V
A
I
L
A
B
L
E
Inlet
Outlet
SVE-2
SVE-3
5/8
SVE-4
SVE-5
1/2
SVE-8
22 (V)
SVE-10
GA or
CP100
5/8
7/8
Type-EBS
Balanced Port Construction ELEMENT SIZE No. 83,
Knife Edge Joint, Standard Tubing Length 5 Feet
TYPE &
CAPACITY
STANDARD
CONNECTIONS
(in. Extended
ODF Solder)
REFRIGERANT
(SPORLAN
CODE) External
Equalizer
Only
T
H
E
R
M
O
S
T
A
T
I
C
C
H
A
R
G
E
S
A
V
A
I
L
A
B
L
E
Inlet
Outlet
EBSVE-8
22 (V) EBSVE-11
GA or
CP100
5/8
7/8
Type-O
Balanced Port Construction ELEMENT SIZE
No. 83 and 33, Knife Edge Joint,
Standard Tubing Length 5 Feet
STANDARD
CONNECTIONS
(in. ODF
Solder)
REFRIGERANT
(Sporlan
Code) T
Y
P
E
&
C
A
P
A
C
I
T
Y
E
L
E
M
E
N
T
S
I
Z
E
N
U
M
B
E
R
T
H
E
R
M
O
S
T
A
T
I
C
C
H
A
R
G
E
S
Inlet
Outlet
OVE-15 1-1/8
OVE-20
7/8
OVE-30
83
OVE-40
OVE-55
22 (V)
OVE-70
33
GA or
CP100
1-1/8
1-3/8
With internal check valve.
R-22 ELEMENT SIZE No. 43, Knife Edge Joint,
Standard Tubing Length 30 Inches
R-410A ELEMENT SIZE No. 45, Knife Edge Joint,
Standard Tubing Length 30 Inches
TYPE &
CAPACITY
STANDARD
CONNECTIONS
(In. ODF Solder)
REFRIGERANT
(Sporlan Code)
External
Equalizer
Only
T
H
E
R
M
O
S
T
A
T
I
C
C
H
A
R
G
E
S
A
V
A
I
L
A
B
L
E
Inlet
Outlet
RCVE-2
RCVE-3
3/8
RCVE-4
1/2
RCVE-5
22 (V)
RCVE-6
1/2
5/8
RCZE-2
RCZE-3
3/8
RCZE-4
1/2
RCZE-5
410A (Z)
RCZE-6
GA
Only
1/2
5/8
ELEMENT SIZE No. 63, Small Capacity No. 7 Large
Capacity Gasket Joint, Standard Tubing Length
10 Feet, Flange Ring Size 2-3/4 OD x 3-3/16 ID.
T
Y
P
E
&
C
A
P
A
C
I
T
Y
STANDARD
CONNECTIONS
(in. ODF Solder)
REFRIGERANT
(Sporlan
Code)
E
x
t
e
r
n
a
l
E
q
u
a
l
i
z
e
r
O
n
l
y
E
L
E
M
E
N
T
S
I
Z
E
N
U
M
B
E
R
T
H
E
R
M
O
S
T
A
T
I
C
C
H
A
R
G
E
S
A
V
A
I
L
A
B
L
E
Inlet
Outlet
WVE-
135
63 GA or
CP100
22(V)
WVE-
180
7 G only
1-5/8
2-1/8
ELEMENT SIZE No. 63, Gasket Joint,
Standard Tubing Length 5 Feet Flange
Ring Size 1-3/4 OD x 1-1/2 ID.
Type &
CAPACITY
STANDARD
CONNECTIONS
(In. Extended
ODF Solder)
REFRIGERANT
(Sporlan Code) External
Equalizer
Only
T
H
E
R
M
O
S
T
A
T
I
C
C
H
A
R
G
E
S
A
V
A
I
L
A
B
L
E
Inlet
Outlet
VVE-52
VVE-70 22 (V)
VVE-100
GA or
CP10
0
1-3/8
1-3/8
TEV REPLACEMENT ELEMENTS
Item Descriptions
KT-43-VGA 30 KT-43-VCP100 30
KT-33-VGA 60 KT-33-VCP100 60
KT-53-VGA 60 KT-53-VCP100 60
KT-83-VGA 60 KT-83-VCP100 60
KT-63-VGA 10 KT-63-VCP100 10
Type-RC
Type-W
Type-V
THERMOSTATIC EXPANSION VALVES
640
T
H
E
R
M
O
S
T
A
T
I
C
E
X
P
A
N
S
I
O
N
V
A
L
V
E
S
THERMOSTATIC EXPANSION VALVE CAPACITIES FOR REFRIGERANTS (Tons of Refrigeration)
AIR CONDITIONING AND HEAT PUMP APPLICATIONS
REFRIGERANT
22 410A
RECOMMENDED THERMOSTATIC CHARGES
VCP100, VGA N, ZGA
EVAPORATOR TEMPERATURE (F)
VALVE
TYPES
NOMINAL
CAPACITY
40 40
RC 2 2.30 2.76
RC 3 3.20 3.83
RC 4 4.20 5.03
RC 5 5.00 5.99
RC 6 6.01 7.20
EBS 8 8.51
EBS 11 11.50
O 15 15.00
O 20 22.20
O 30 30.50
O 40 40.30
O 55 55.00
O 70 73.00
S 2 2.00
S 3 3.20
S 4 4.50
S 5 5.20
S 8 8.00
S 10 10.00
S 15 15.00
V 52 52.00
V 70 73.00
V 100 100.00
W 135 143.00
W 180 180.00
LIQUID TEMPERATURE ENTERING TEV (F)
60 70 80 90 100 110 120 130 140 REFRIGERANT
CORRECTION FACTOR, CF LIQUID TEMPERATURE
22 1.23 1.17 1.12 1.06 1.00 0.94 0.88 0.82 0.76
410A 1.32 1.24 1.16 1.08 1.00 0.92 0.83 0.73 0.62
These factors include corrections for liquid refrigerant density and
net refrigerating effect and are based on an evaporator temperature
of 40 F.
PRESSURE DROP ACROSS TEV (PSI)
75 100 125 150 160 175 200 225 250 275
CORRECTION FACTOR, CF PRESSURE DROP
REFRIGERANT
40F EVAPORATOR TEMPERATURE
22 0.87 1.00 1.12 1.22 1.32 1.41 1.50 1.58 1.66
410A 0.68 0.79 0.88 0.97 1.00 1.05 1.12 1.19 1.25 1.31
TEV CAPACITY = TEV RATING X CF LIQUID TEMPERATURE X
CF PRESSURE DROP
Example: Calculate the actual capacity of a nominal 2 ton, R-22,
Type RC valve at 40 F evaporator, 80 F liquid temperature enter-
ing the TEV, and 75 psi pressure drop across the TEV:
TEV capacity = 2.30 (from rating chart) x 1.12 (CF liquid tempera-
ture) x 0.87 (CF pressure drop)
= 2.24 tons
THERMOSTATIC EXPANSION VALVES
641
T
H
E
R
M
O
S
T
A
T
I
C
E
X
P
A
N
S
I
O
N
V
A
L
V
E
S
SPORLAN THERMOSTATIC EXPANSION VALVE
PART NUMBERS
Type S Series Valves
Part No DESCRIPTION
SVE-10-GA5/8X7/8ODF SVE-10-GA 5/8X7/8 ODF
SVE-15-GA7/8X1-1/8ODF SVE-15-CP100 7/8X1-1/8 ODF
SVE-2-GA1/2/5/8ODF SVE-2-GA 1/2X5/8 ODF
SVE-3-GA1/2X5/8ODF SVE-3-GA 1/2X5/8 ODF
SVE-4-GA1/2X7/8ODF SVE-4-GA 1/2X7/8 ODF
SVE-5-GA1/2X7/8ODF SVE-5-GA 1/2X7/8 ODF
SVE-8-GA5/8X7/8ODF SVE-8-GA 5/8X7/8 ODF
SVE10CP1005/8X7/8ODF SVE-10-CP100 5/8X7/8 ODF
SVE15CP1007/8X11/8OD SVE-15-CP100 7/8X1-1/8 ODF
SVE2-CP1001/2X5/8OD SVE-2-CP100 1/2X5/8 ODF
SVE3-CP1001/2X5/8OD SVE-3-CP100 1/2X5/8 ODF
SVE4-CP1001/2X7/8OD SVE-4-CP100 1/2X5/8 ODF
SVE5-CP1001/2X7/8OD SVE-5-CP100 1/2X5/8 ODF
SVE8CP1005/8X7/8ODF SVE-8-CP100 5/8X7/8 ODF
Type RC Series Valves
Part No DESCRIPTION
RCVE-2-GA3/8X1/2ODF RCVE-2-GA 3/8X1/2 ODF
RCVE-3-GA3/8X1/2ODF RCVE-3-GA 3/8X1/2 ODF
RCVE-4-GA1/2X1/2ODF RCVE-4-GA 1/2X1/2 ODF
RCVE-4-GA1/2X5/8ODF RCVE-4-GA 1/2X5/8 ODF
RCVE-5-GA1/2X1/2ODF RCVE-5-GA 1/2X1/2 ODF
RCVE-5-GA1/2X5/8ODF RCVE-5-GA 1/2X5/8 ODF
RCVE-6-GA1/2X1/2ODF RCVE-6-GA 1/2X1/2 ODF
RCVE-6-GA1/2X5/8ODF RCVE-6-GA 1/2X5/8 ODF
RCZE-2-GA3/8X1/2ODF RCZE-2-GA 3/8X1/2 ODF
RCZE-3-GA3/8X1/2ODF RCZE-3-GA 3/8X1/2 ODF
RCZE-4-GA1/2X1/2ODF RCZE-4-GA 1/2X1/2 ODF
RCZE-5-GA1/2X5/8ODF RCZE-5-GA 1/2X5/8 ODF
RCZE-6-GA1/2X5/8ODF RCZE-6-GA 1/2X5/8 ODF
Part No DESCRIPTION
EBSVE-11-GA5/8X7/8OD EBSVE-11-GA 5/8X7/8 ODF
EBSVE-8-CP1005/8X7/8 EBSVE-8-C100 5/8X7/8 ODF
EBSVE-8-GA5/8X7/8ODF EBSVE-8-GA 5/8X7/8 ODF
EBSVE11CP1005/8X7/8O EBSVE-11-CP100 5/8X7/8 ODF
Part No DESCRIPTION
OVE-20-GA7/8X7/8ODF TXV, VALVE 7/8X7/8 ODF
OVE15CP1007/8X11/8O OVE-15-CP100 7/8X1-1/8 ODF
OVE15GA7/8X1-1/8ODF OVE-15-GA 7/8X1-1/8 ODF
OVE20CP1007/8X1-3/8OD OVE-20-CP100 7/8X1-3/8 ODF
OVE20GA7/8X1-1/8ODF OVE-20-GA 7/8X1-1/8 ODF
OVE30CP1001-1/8X1-3/8O OVE-30-CP100 1-1/8X1-3/8 ODF
OVE30GA1-1/8X1-3/8OD OVE-30-GA 1-1/8X1-3/8 ODF
OVE40CP10011/8X13/8O OVE-40-CP100 1-1/8X1-3/8 ODF
OVE40CP10011/8X15/8O OVE-40-CP100 1-1/8X1-5/8 ODF
OVE40GA1-1/8X1-3/8OD OVE-40-GA 1-1/8X1-3/8 ODF
OVE40GA1-1/8X1-5/8OD OVE-40-GA 1-1/8X1-5/8 ODF
OVE55CP10011/8X13/8O OVE-55-CP100 1-1/8X1-3/8 ODF
OVE55CP10011/8X15/8O OVE-55-CP100 1-1/8X1-5/8 O
OVE55GA1-1/8X1-3/8OD OVE-55-GA 1-1/8X1-3/8 ODF
OVE55GA1-1/8X1-5/8OD OVE-55-GA 1-1/8X1-5/8 ODF
OVE70CP10011/8X13/8O OVE-70-CP100 1-1/8X1-3/8 ODF
OVE70CP10011/8X15/8O OVE-70-CP100 1-1/8X1-5/8 ODF
OVE70GA1-1/8X1-3/8OD OVE-70-GA 1-1/8X1-3/8 ODF
OVE70GA1-1/8X1-5/8OD OVE-70-GA 1-1/8X1-5/8 ODF
Part No DESCRIPTION
VVE-100-GA13/8X13/8 VVE-100-GA 1-3/8X1-3/8 ODF
VVE-52-GA13/8X138OD VVE-52-GA 1-3/8X1-3/8 ODF
VVE-70-GA13/8X13/8OD VVE-70-GA 1-3/8X1-3/8 ODF
VVE100CP10013/8X13/8 VVE-100-CP100 1-3/8X1-3/8 ODF
VVE52CP10013/8X13/8 VVE-52-CP100 1-3/8X1-3/8 ODF
VVE70CP10013/8X13/8O VVE-70-CP100 1-3/8X1-3/8 ODF
Part No DESCRIPTION
WVE-135-GA15/8X21/8 WVE-135GA 1-5/8X2-1/8 ODF
WVE135CP10015/8X21/8 WVE-135-CP100 1-5/8X2-1/8 ODF
Type EBS Series Valves
Type O Series Valves
Type V Series Valves
Type W Series Valves
THERMOSTATIC EXPANSION VALVES
642
S
O
L
E
N
O
I
D
V
A
L
V
E
S
SPORLAN SOLENOID VALVES
Refrigerants 22, 134a, 402A, 404A, 407C, 502, 507
SPECIFICATIONS
6 Proven Benefits of Sporlan Solenoid Valves
Molded coil for most sizes.
Class F temperature rating Coil types MKC-1, OMKC-1, MKC-2, and OMKC-2.
Extremely rugged, simple design few parts.
E Series may be brazed without disassembly.
Tight closing through use of synthetic seating material.
Can be used on Refrigerants 22, 134a, 401A, 402A, 404A, 407C, 502 and 507 because of high MOPD ratings.
Sporlan Solenoid Valves are made in two general types, normally closed and normally open. The normally closed types
may be further sub-divided into direct acting and pilot operated types.
The Sporlan E series solenoid valves feature extended solder type connections as standard. One important benefit to the
user is that all valves in the E series can be installed without disassembly using either low or no silver content brazing alloy.
The E series is interchangeable with the B series; solder type valves, providing the overall length can be accommodated.
All valves in the E series have the same capacities as the B series with the exception of the E42.
Its capacity is approximately 15% greater than the MA42.
All Sporlan solenoid valves are designed for liquid, suction and discharge gas applications.
Most Sporlan Solenoid Valves are listed by Underwriters Laboratories, Inc. Guide No. Y10Z File No.MH4576 and
Canadian Standards Association Guide 440-A-O, Class 3221, File 19953 and CE provisions of the LVD 73/23/EEC.
LIQUID CAPACITY SELECTION TABLE
PART NO TONS OF REFRIGERATION**
R-22 R-134a R-401A R-402A
PRESSURE DROP psi*
E
SERIES
VALVE 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
E3 0.9 1.3 1.6 1.9 2.1 0.8 1.2 1.5 1.8 2.0 0.9 1.3 1.6 1.9 2.1 0.6 0.9 1.1 1.2 1.4
E5 1.6 2.3 2.8 3.3 3.6 1.5 2.1 2.6 3.0 3.4 1.6 2.3 2.8 3.3 3.7 1.1 1.5 1.9 2.1 2.4
E6 2.9 4.0 4.9 5.7 6.4 2.7 3.8 4.6 5.3 5.9 2.9 4.1 4.9 5.7 6.4 1.9 2.7 3.3 3.8 4.2
E9 4.7 6.6 8.1 9.3 10.4 4.4 6.2 7.5 8.7 9.7 4.7 6.6 8.1 9.3 10.4 3.1 4.4 5.3 6.2 6.9
E10 6.4 9.1 11.1 12.8 14.3 6.0 8.5 10.4 12.0 13.4 6.4 9.1 11.1 12.8 14.4 4.2 6.0 7.3 8.5 9.4
E14 9.1 12.9 15.8 18.2 20.3 8.5 12.0 14.7 17.0 18.9 9.1 12.9 15.8 18.2 20.4 6.0 8.5 10.4 12.0 13.4
E19 13.9 19.8 24.2 28.0 31.4 13.0 18.4 22.6 26.1 29.2 14.0 19.8 24.3 28.1 31.4 9.2 13.0 16.0 18.5 20.7
E25 23.8 33.8 41.4 47.8 53.5 22.2 31.5 38.6 44.6 49.9 23.9 33.8 41.4 47.9 53.6 15.7 22.2 27.3 31.5 35.3
E34 33.2 47.0 57.6 66.5 74.4 31.0 43.8 53.7 62.0 69.4 33.3 47.1 57.7 66.6 74.5 21.9 31.0 38.0 43.9 49.0
60.9 82.3 98.2 111 123 56.7 76.7 91.5 104 114 61.0 82.5 98.0 112 123 40.4 54.6 65.1 73.8 81.4
E42 73.5 104 127 147 164 68.6 96.9 119 137 153 73.6 104 127 147 165 48.5 68.5 83.9 96.9 108
109 147 175 199 219 101 137 163 185 204 109 147 176 199 220 72.1 97.5 116 132 145
PART NO TONS OF REFRIGERATION**
404A 407C 502 507
PRESSURE DROP psi*
E
SERIES
VALVES
1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
E3 0.6 0.9 1.1 1.2 1.4 0.8 1.2 1.5 1.7 1.9 0.6 0.8 1.0 1.2 1.4 0.6 0.8 1.0 1.2 1.4
E5 1.1 1.5 1.9 2.1 2.4 1.5 2.1 2.6 3.0 3.4 1.0 1.5 1.8 2.1 2.4 1.0 1.5 1.8 2.1 2.4
E6 1.9 2.7 3.3 3.8 4.2 2.6 3.7 4.5 5.2 5.8 1.9 2.6 3.2 3.7 4.1 1.9 2.6 3.2 3.7 4.1
E9 3.1 4.4 5.4 6.2 6.9 4.3 6.1 7.4 8.6 9.6 3.0 4.3 5.2 6.0 6.8 3.0 4.3 5.2 6.0 6.7
E10 4.2 6.0 7.3 8.5 9.5 5.9 8.3 10.2 11.8 13.2 4.2 5.9 7.2 8.3 9.3 4.2 5.9 7.2 8.3 9.3
E14 6.0 8.5 10.4 12.0 13.4 8.4 11.8 14.5 16.7 18.7 5.9 8.4 10.2 11.8 13.2 5.9 8.3 10.2 11.8 13.2
E19 9.2 13.1 16.0 18.5 20.7 12.8 18.2 22.3 25.8 28.8 9.0 12.8 15.7 18.2 20.3 9.0 12.8 15.7 18.1 20.3
E25 15.7 22.3 27.4 31.6 35.4 21.9 31.0 38.0 44.0 49.2 15.5 21.9 26.8 31.0 34.7 15.4 21.8 26.8 30.9 34.6
E34 22.0 31.1 38.1 44.0 49.2 30.5 43.2 53.0 61.2 68.4 21.5 30.5 37.4 43.2 48.3 21.5 30.4 37.3 43.1 48.2
40.8 55.2 65.8 74.6 82.2 56.4 76.3 91.1 103 114 39.5 53.4 63.7 72.2 79.5 39.8 53.8 64.2 72.8 80.2
E42 48.6 68.8 84.2 97.2 109 67.6 95.6 117 135 151 47.7 67.4 82.5 95.3 107 47.6 67.3 82.4 95.1 106
72.8 98.5 118 133 147 101 136 163 184 203 70.4 95.3 114 129 142 71.0 96.1 115 130 143
*Do not use below 1 psi pressure drop, except Types E3 and A3 valves.
**Capacities are based on 40 F evaporator and 100 F liquid. Valve types whether Normally Closed or Normally Open have the same
capacities, i.e., B10 or OB10, E10 or OE10.
Solenoid valves for brine applications consult Sporlan Valve Company, Washington, MO.
SOLENOID VALVES
643
S
O
L
E
N
O
I
D
V
A
L
V
E
S
SPORLAN SOLENOID VALVES
SPECIFICATIONS
Refrigerants 22, 134a, 402A, 404A, 407C, 502, 507
PART NOE Series Extended Connections
Without Manual Lift Stem With Manual Lift Stem Normally Closed CONNECTIONS (in) PORT SIZE (in) MOPD psi AC WATTS
E3S120 .101 300 10
E3S130 3/8 ODF Solder .101 300 10
E5S120 1/4 ODF Solder .150 300 10
E5S130 3/8 ODF Solder .150 300 10
E6S130 ME6S130 3/8 ODF Solder 3/16 300 10
E6S140 ME6S140 1/2 ODF Solder 3/16 300 10
E9S240 ME9S240 1/2 ODF Solder 9/32 300 15
E10S240 ME10S240 1/2 ODF Solder 5/16 300 15
E10S250 ME10S250 5/8 ODF Solder 5/16 300 15
E14S250 ME14S250 5/8 ODF Solder 7/16 300 15
E19S250 ME19S250 5/8 ODF Solder 19/32 300 15
E19S270 ME19S270 7/8 ODF Solder 19/32 300 15
E25S270 ME25S270 7/8 ODF Solder 25/32 300 15
E25S290 ME25S290 1-1/8 ODF Solder 25/32 300 15
E34S290 ME34S290 1-1/8 ODF Solder 1 300 15
E34S2110 ME34S2110 1-3/8 ODF Solder 1 300 15
E42S2130 ME42S2130 1-5/8 ODF Solder 1-5/16 300 15
E42S2170 ME42S2170 2-1/8 ODF Solder 1-5/16 300 15
SOLENOID PARTS KITS
Part No.
KS-B6/E6 KS-B19/E19
KS-B9/E9 KS-B25/E25
KS-B10/E10 KS-B34/E34
KS-B14/E14 KS-B42/E42
SOLENOID COILS
Coil Type and Voltage
MKC-1 and MKC-2 24 JAQ and CAQ
MKC-1 and MKC-2 120 JAM and CAM
MKC-1 and MKC-2 208-240 JAN and CAN
MKC-1 and MKC-2 Dual JAU and CAU
SOLENOID VALVES
644
T
H
R
E
E
-
W
A
Y
H
E
A
T
R
E
C
L
A
I
M
V
A
L
V
E
S
THREE WAY HEAT RECLAIM VALVES
Sporlan Heat Reclaim Valves are tight synthetic seating three way
valves designed specifically to divert hot gas from the normal to
auxiliary condenser.
OPERATION
B TYPE
Normal (Outdoor) Condenser De-energized With the pilot valve
de-energized, high side pressure is prevented from entering the cavity
above the piston-seat assembly. At the same time the upper pilot port
is opened to suction pressure. The resulting pressure differential
across the piston moves the piston-seat assembly to close the reclaim
(upper) main port. When the upper pilot port is open, the cavity above the
piston is open to suction. Pump out of the reclaim condenser is controlled
by the bleed rate through the piston. After the reclaim condenser has been
pumped out, and the valve continues to operate in the normal condenser
mode, all flow ceases, thus eliminating high to low side bleed and the
resulting capacity loss.
C TYPE
Normal (Outdoor) Condenser De-energized With the
pilot valve de-energized, high side pressure is prevented from
entering cavity above the piston-seat assembly. At the same
time the upper pilot port is opened to suction pressure. The
resulting pressure differential across the piston moves the
piston-seat assembly to close the reclaim (upper) main port.
The non bleed piston prevents high to low side bleed with the
system operating in the normal condenser mode.
B AND C TYPE
Reclaim (Reheat) Condenser Energized When the pilot
valve is energized, high side pressure is permitted to flow thru
the lower pilot port. At the same time the upper pilot port is
closed to suction. High side pressure on top of the piston
moves the piston-seat assembly to close the normal
condenser port and open the reclaim (upper) main port. With
the upper pilot port closed there is no high to low side bleed
loss with the system operating in the reclaim mode.
HEAT RECLAIM SYSTEMS
PART NO* Sporlan Model
10G711B 120/50-60 JAM
10G79B 120/50-60 JAM
12D11B LESS COIL
12D11C LESS COIL
12D13B LESS COIL
12D13B-SC LESS COIL
12D13C LESS COIL
16D17B LESS COIL
16D17B-SC LESS COIL
16D17C LESS COIL
8D7B 208-240/50-60 JAN
8D7B DUAL JAU
8D7C LESS COIL
8D9B DUAL JAU
8D9B LESS COIL
8D9B-CV 24/50-60 LAQ
With Head Pressure Control
With Split Condenser Control
With Integral Check Valve
When employing heat reclaim on a refrigeration system, the
addition of head pressure controls is important not only to
maintain liquid pressure at the expansion valve inlet, but also to
assure availability of quality hot gas at the reclaim heat
exchanger. Split condenser controls are important to minimize
the required refrigerant charge for wintertime operation. And,
integral check valves are important to minimize installation
costs.
8D9C LESS COIL
Note: SC - split condenser; CV - check valve.
*( ) Please contact your local Carlyle Certified Refrigeration Partner or RCD Customer Service for P/N and Pricing.
THREE-WAY HEAT RECLAIM VALVES
645
F
I
L
T
E
R
D
R
I
E
R
S
SPORLAN CATCH-ALL SEALED TYPE
The universal acceptance of the Catch-All Filter Drier
is due to its unique molded porous core, consisting of a
blend of highly effective desiccants. The quality
features built into it assure years of service on any
refrigeration system.
MOISTURE The Catch-All Filter Drier removes
moisture from the refrigerant by adsorbing and retaining
it deep within the desiccant granules.
FOREIGN MATTER The Catch-All Filter Drier will
filter out scale, solder particles, carbon, sludge, dirt, or
any other foreign matter with negligible pressure drop.
Fine particles that would go through an ordinary
strainer are removed down to a minimum size in one
pass filtration. The large filtering area of the Catch-All
Filter Drier core permits it to collect a large amount of
dirt without plug up.
OIL SLUDGE AND VARNISH Even the best
refrigeration oils break down to produce varnish, sludge,
and organic acids. Only the Catch-All Filter Drier is
capable of removing these products of oil decomposition.
ACID The Catch-All Filter Drier is unexcelled in
acid removal ability. The hydrochloric, hydrofluoric,
and various organic acids are adsorbed and held by
the desiccant in a manner similar to the adsorption of
moisture. Tests have demonstrated that the Catch-
All Filter Drier will remove over 10 times as much
acid as the desiccant used in most driers. This ability,
along with its excellent ability to clean up the oil, is
responsible for the excellent field performance in
cleaning up severely contaminated
systems.SPECIAL APPLICATIONS A special
HH core Catch-All Filter Drier is available to
remove wax which frequently causes difficulty on low
temperature Refrigerant 22 and 502 systems. For cap
tube systems, use the C-032-CAP or CW-032-CAP
Catch-All which has fittings suitable for attaching to
any size capillary tube.
RememberIts not how much moisture you
remove from a refrigeration system that counts,
its how little moisture is left
SEALED TYPE Liquid Line and Suction Line
SPECIFICATIONS
Listed by Underwriters Laboratories Inc. Guide SMGT-File No. SA-1756A& B. Maximum Rated Pressure of 650 psi, except for
the C-140 Series which has a maximum pressure of 450 psi.
LIQUID LINE TYPE
SUCTION LINE
TYPE
OVERALL
LENGTH (in.)
SAE Flare ODF Solder ODF Solder
CONNECTION
SIZE (in.)
VOLUME OF
DESICCANT
(cu in.) SAE Flare ODF
Solder
SOLDER
SOCKET
DEPTH (in.)
DIAMETER
of BODY
(in.)
C-032 C-032-S 1/4 4.19 3.81 0.38
C-033 C-033-S 3/8
3
4.69 3.88 0.44
1.75
C-052
C-053
C-052-S
C-0525-S
C-053-S
1/4
5/16
3/8
5
4.75
5.19
4.19
4.38
4.31
0.38
0.44
0.44
2.44
C-082
C-083
C-084
C-082-S
C-0825-S
C-083-S
C-084-S
C-084-S-T-HH
1/4
5/16
3/8
1/2
9
5.62
6.06
6.31
5.12
5.31
5.25
5.44
0.38
0.44
0.44
0.50
2.62
C-162
C-163
C-164
C-165
C-162-S
C-1625-S
C-163-S
C-164-S
C-165-S
C-167-S
C-164-S-T-HH
C-165-S-T-HH
C-166-S-T-HH
C-167-S-T-HH
1/4
5/16
3/8
1/2
5/8
3/4
7/8
16
6.25
6.75
6.94
7.25
5.75
5.94
5.88
6.00
6.31
6.75
6.93
0.38
0.44
0.44
0.50
0.62
0.62
0.75
3.00
C-303
C-304
C-305
C-303-S
C-304-S
C-305-S
C-306-S
C-307-S
C-309-S
C-305-S-T-HH
C-306-S-T-HH
C-307-S-T-HH
C-309-S-T-HH
3/8
1/2
5/8
3/4
7/8
1-1/8
30
9.69
9.88
10.19
8.88
9.00
9.25
9.65
9.80
9.75
0.44
0.50
0.62
0.62
0.75
0.96
3.00
C-413
C-414
C-415
C-414-S
C-415-S
C-417-S
C-419-S
C-417-S-T-HH
C-419-S-T-HH
3/8
1/2
5/8
7/8
1-1/8
41
9.56
9.94
10.25
9.05
9.35
9.81
9.75
0.50
0.62
0.75
0.90
3.50
C-437-S-T-HH
C-439-S-T-HH
C-4311-S-T-HH
C-4313-S-T-HH
7/8
1-1/8
1-3/8
1-5/8
48
10.34
10.62
10.94
10.94
0.75
0.94
1.00
1.06
4.75
C-607-S
C-609-S
C-607-S-T-HH
C-609-S-T-HH
7/8
1-1/8
60
16.00
16.00
0.75
0.90
3.00
COMPACT STYLE
C-144-S-TT-HH
C-145-S-TT-HH
C-146-S-TT-HH
C-147-S-TT-HH
C-149-S-TT-HH
1/2
5/8
3/4
7/8
1-1/8
14
4.14
4.38
4.83
4.97
4.93
0.50
0.66
0.66
0.75
0.96
4.44
FILTER DRIERS
646
F
I
L
T
E
R
D
R
I
E
R
S
SPORLAN CATCH-ALL REPLACEABLE CORE TYPE
The rugged construction of the Replaceable Core Catch-All has proven itself in the field for
many years. The design features include:
1. The famous molded porous core for maximum
contaminant removal. The core cannot swell,
powder, or packassuring ease of installation
and removal;
2. The bolt and nut attachment of the end plate
provides simple and trouble free installation;
3. The internal construction gives a one piece
assembly and assures proper core alignment;
4. A complete line of fitting sizes
all with copper fittings;
5. No plastic parts are used all
internal parts are plated steel;
6. A corrosion resistant powder
paint protects the exterior of the
shell.
REPLACEABLE CORE TYPE
TYPE CONNECTIONS (in)
ODF Solder
NUMBER OF
CORES
CORE PART NO VOLUME OF
DESICCANT (cu in)
MOUNTING
BRACKETS
OVERALL
LENGTH (in)
C-485,C-485-G 5/8 1 RCW-48, RC-4864, or RC-4864-HH 48 A-685 9.15
C-485-T 5/8 1 RCW-48, RC-4864, or RC-4864-HH 48 A-685 9.15
C-487,C-487-G 7/8 1 RCW-48, RC-4864, or RC-4864-HH 48 A-685 9.30
C-487-T 7/8 1 RCW-48, RC-4864, or RC-4864-HH 48 A-685 9.30
C-489-T,C-489-G 1-1/8 1 RCW-48, RC-4864, or RC-4864-HH 48 A-685 9.50
C-4811-T,C-4811-G 1-3/8 1 RCW-48, RC-4864, or RC-4864-HH 48 A-685 9.60
C-4813-T,C-4813-G 1-5/8 1 RCW-48, RC-4864, or RC-4864-HH 48 A-685 9.60
C-967,C-967-G 7/8 2 RCW-48, RC-4864, or RC-4864-HH 96 A-685 14.84
C-967-T 7/8 2 RCW-48, RC-4864, or RC-4864-HH 96 A-685 14.84
C-969,C-969-G 1-1/8 2 RCW-48, RC-4864, or RC-4864-HH 96 A-685 15.04
C-969-T 1-1/8 2 RCW-48, RC-4864, or RC-4864-HH 96 A-685 15.04
C-9611-T,C-9611-G 1-3/8 2 RCW-48, RC-4864, or RC-4864-HH 96 A-685 15.14
C-9613-T,C-9613-G 1-5/8 2 RCW-48, RC-4864, or RC-4864-HH 96 A-685 15.14
C-1449,C-1449-G 1-1/8 3 RCW-48, RC-4864, or RC-4864-HH 144 A-685 20.58
C-1449-T 1-1/8 3 RCW-48, RC-4864, or RC-4864-HH 144 A-685 20.58
C-14411,C-14411-G 1-3/8 3 RCW-48, RC-4864, or RC-4864-HH 144 A-685 20.68
C-14411-T 1-3/8 3 RCW-48, RC-4864, or RC-4864-HH 144 A-685 20.68
C-14413-T,C-14413-G 1-5/8 3 RCW-48, RC-4864, or RC-4864-HH 144 A-685 20.68
C-19211,C-19211-G 1-3/8 4 RCW-48, RC-4864, or RC-4864-HH 192 A-685 26.22
C-19211-T 1-3/8 4 RCW-48, RC-4864, or RC-4864-HH 192 A-685 26.22
C-19213,C-19213-G 1-5/8 4 RCW-48, RC-4864, or RC-4864-HH 192 A-685 26.22
C-19213-T 1-5/8 4 RCW-48, RC-4864, or RC-4864-HH 192 A-685 26.22
C-30013,C-30013-G 1-5/8 3 RCW-100, RC-10098, or RC-10098-HH 300 A-175-2 26.22
C-30013-T 1-5/8 3 RCW-100, RC-10098, or RC-10098-HH 300 A-175-2 27.94
C-30017-T,C-30017-G 2-1/8 3 RCW-100, RC-10098, or RC-10098-HH 300 A-175-2 28.06
C-40017,C-40017-G 2-1/8 4 RCW-100, RC-10098, or RC-10098-HH 400 A-175-2 28.06
C-40017-T 2-1/8 4 RCW-100, RC-10098, or RC-10098-HH 400 A-175-2 34.56
C-40021-T,C-40021-G 2-5/8 4 RCW-100, RC-10098, or RC-10098-HH 400 A-175-2 34.57
C-40025-T,C-40025-G 3-1/8 4 RCW-100, RC-10098, or RC-10098-HH 400 A-175-2 34.44
C-40029-T,C-40029-G 3-5/8 4 RCW-100, RC-10098, or RC-10098-HH 400 A-175-2 34.81
C-40033-T,-C-40033-G 4-1/8 4 RCW-100, RC-10098, or RC-10098-HH 400 A-175-2 35.12
OPTIONAL SECONDARY FILTER ORDER SEPARATELY
Filter Part No. Description Quantity Required
FS-480
FS-960
FS-1440
Filter for C-480 Series Shell 1
FS-19200
FILTER DRIERS
647
F
I
L
T
E
R
D
R
I
E
R
S
SPORLAN CATCH-ALL FILTER DRIERS
LIQUID LINE RATINGS AND SELECTION RECOMMENDATIONS
RATINGS AT ARI STANDARD CONDITIONS SELECTION RECOMMENDATIONS (Tons)
Water Capacity-Drops Refrigeration Air Conditioning
Refrigerant
22
60 PPM
Refrigerant
134a
50PPM
Refrigerant
404A/507 50
PPM
Refrigerant
407C
50 PPM
Refrigerant
410A
50 PPM
Refrigerant Flow
Capacity**
(Tons at 1 psi P)
Commercial & Low
Temperature
Equipment
Field Replacement
or Field Built Up
Systems
TYPE
SURFACE
FILTERING
AREA
75F 125 F 75 F 125 F 75 F 125 F 75 F 125 F 75 F 125 F 22 134a 404A
507
407C 410A 12 &
134a
22 404A, 502
& 507
12 &
134a
22, 407C &
410A
C-032
C-032-CAP
C-032-S
C-032-F
C-032-FM
1.5
1.3
1.0
1.3
1.4
C-033 3.5 3.2 2.3 3.2 3.4
C-033-S
9
61
50
67
48
71
58
52
17
27
20
3.8 3.5 2.6 3.5 3.7
1/4
1/4
1/4
1/2
1/2
C-052
C-052-S
C-052-F
C-052-FM
2.1
1.9
1.4
1.9
2.0
C-0525-S 3.4 3.1 2.3 3.1 3.3
C-053 4.1 3.8 2.7 3.8 4.0
C-053-S
15
146
119
158
114
169
138
123
40
63
48
4.7 4.3 3.1 4.3 4.5
1/3
1/3
1/3
3/4
thru
1
3/4
thru
2
C-082
C-082-S
2.1
1.9
1.4
1.9
2.0
C-0825-S 3.7 3.3 2.4 3.3 3.5
C-083 4.5 4.2 3.0 4.2 4.4
C-083-S 5.2 4.7 3.4 4.7 5.0
C-084 8.7 7.9 5.9 8.0 8.5
C-084-S
21
240
196
261
188
279
227
202
65
104
78
9.6 8.8 6.4 8.8 9.4
1/2
thru
1-1/2
1/2
thru
1-1/2
1/2
thru
1
3/4
thru
2
1
thru
2
C-162
C-162-S
2.1
1.9
1.4
1.9
2.0
C-1625-S 3.7 3.3 2.4 3.3 3.5
C-163 4.5 4.2 3.0 4.2 4.4
C-163-S 5.2 4.7 3.4 4.7 5.0
C-164 10.1 9.3 6.8 9.3 9.8
C-164-S 11.0 10.1 7.3 10.1 10.7
C-165 13.8 12.6 9.2 12.7 13.4
C-165-S
33
346
297
396
285
424
345
307
100
158
119
15.9 14.5 10.6 14.6 15.5
1
thru
2
1-1/2
thru
3
3/4
thru
2
1
thru
5
1-1/2
thru
5
C-303 4.6 4.2 3.0 4.2 4.4
C-303-S 5.3 4.7 3.4 4.7 5.0
C-304 10.1 9.3 6.8 9.3 9.8
C-304-S 11.0 10.1 7.3 10.1 10.7
C-305 14.9 13.6 9.9 13.7 14.5
C-305-S 16.9 15.5 11.3 15.5 16.4
C-307-S
53
696
567
756
545
809
658
586
189
302
227
21.6 19.8 14.4 19.9 21.0
3
thru
5
3
thru
5
2
thru
5
3
thru
7-1/2
4
thru
10
C-414 11.5 10.5 7.6 10.5 11.1
C-414-S 12.4 11.4 8.3 11.4 12.1
C-415 15.8 14.5 10.6 14.6 15.4
C-415-S 17.5 16.1 11.8 16.2 17.1
C-417-S 22.1 20.3 14.8 20.4 21.5
C-419-S
67
936
713
1017
733
1088
885
788
254
407
305
24.3 22.3 16.3 22.4 23.7
5
thru
10
5
thru
12
5
thru
10
5
thru
12
7-1/2
thru
15
C-607-S 29.1 26.6 19.5 26.8 28.4
C-609-S
106
1392
1134
1512
1090
1618
1316
1172
378
604
454
33.2 30.4 22.3 30.7 32.4
15
15
10
15
20
*The filtration area is equal to the core surface area plus the large internal surface available for depth filtration.
20 drops = 1 gram = 1cc.
**Based on 86 F liquid line temperature and a refrigerant flow of 3.1 pounds per minute per ton of Refrigerant 134a; 2.9 pounds per minute per ton of
Refrigerant 22; 3.9 pounds per minute per ton for Refrigerant 404A; 2.9 pounds per minute per ton for Refrigerant 407C; 2.8 pounds per minute per ton for
Refrigerant 410A and 4.1 pounds per minute per ton for Refrigerant 507. Ratings in accordance to ARI Standard 710.
NOTES:
1. R-12 water capacity values are approximately 15 percent greater than R-134a. R-502 water capacities are similar to R-404A and R-507.
2. The variation in flow ratings of filter-driers having the same size core and shell is caused by the difference in connection sizes used.
FILTER DRIERS
648
F
I
L
T
E
R
D
R
I
E
R
S
SPORLAN CATCH-ALL SUCTION LINE FILTER DRIER RECOMMENDATIONS
FOR CLEAN-UP AFTER BURNOUT AND NEW SYSTEMS
SYSTEM CAPACITY IN HORSEPOWER
Refrigerant 22 & 407C Refrigerant
12, 134a, 404A, 502 & 507
TYPE NUMBER
CONNECTIONS
(in.)
ODF Solder
Number of
Cores
CORE
PART NO
LENGTH
(in.)
SOLDER
SOCKET
DEPTH
(in.)
WIDTH
(in.)
Permanent
Installation
with Cores
Temporary
Installation
Cores for
Cleanup;
Filter
Elements
after Cleanup
Permanent
Installation
with Cores
Temporary
Installation
Cores for
Cleanup;
Filter
Elements
after Cleanup
C-084-S-T-HH 1/2 5.44 0.50
2.62 1 1/2
C-164-S-T-HH 1/2 6.00 0.50
C-165-S-T-HH 5/8 6.31 0.62
C-166-S-T-HH 3/4 6.75 0.62
2
1
C-167-S-T-HH 7/8 6.93 0.75
3.00
C-305-S-T-HH 5/8 9.25 0.62
C-306-S-T-HH 3/4 9.65 0.62
3
C-307-S-T-HH 7/8 9.80 0.75
2
C-309-S-T-HH 1-1/8 9.75 0.96
3.00
C-417-S-T-HH 7/8 9.81 0.75
5
C-419-S-T-HH 1-1/8 9.75 0.96
3.50
3
C-437-S-T-HH 7/8 10.34 0.75
C-439-S-T-HH 1-1/8 10.74 0.96
7-1/2
4
C-4311-S-T-HH 1-3/8 10.94 1.00
C-4313-S-T-HH 1-5/8 10.94 1.06
4.75
10
5
C-607-S-T-HH 7/8 16.00 0.75
S
E
A
L
E
D
T
Y
P
E
C-609-S-T-HH 1-1/8 16.00 0.96
3.00
5
3
C-144-S-TT-HH 1/2 4.14 0.50
2 1
C-145-S-TT-HH 5/8 4.38 0.62
C-146-S-TT-HH 3/4 4.83 0.69
3
2
C-147-S-TT-HH 7/8 4.97 0.75
S
E
A
L
E
D
T
Y
P
E
C
O
M
P
A
C
T
S
T
Y
L
E
C-149-S-TT-HH 1-1/8
Sealed
Type Filter
Driers
Sealed
Type Filter
Driers
4.93 0.96
4.44
5
Select these
types on
basis of
permanent
installation
3
Select these
types on
basis of
permanent
installation
C-30013-G 1-5/8
C-30017-G 2-1/8
3
C-40017-G 2-1/8
25
50
15
25
C-40021-G 2-5/8
C-40025-G 3-1/8
C-40029-G 3-5/8 R
E
P
L
A
C
E
A
B
L
E
C
O
R
E
T
Y
P
E
*
C-40033-G 4-1/8
4
RC-10098-HH
or
RC-10098
30
60
20
30
*See page for RSF shells.
CATCH-ALL SUCTION LINE FILTER DRIER SELECTION INSTRUCTIONS
Selection of the proper Catch-All Suction Line Filter Drier will
depend upon the intended usage. Either the Permanent
Installation with Cores or Temporary Installation Cores for
Cleanup; Filter Elements after Cleanup column may be used.
When the best possible system protection is desired, the
Permanent with Cores column should be used for selection.
These recommendations are made on the basis of a low pressure
drop, and as a result the cores can be left in the shell for
maximum drying and acid removal when the system returns to
normal operation delivering its full rated capacity.
An alternate selection that is satisfactory and less
expensive is to install cores temporarily for cleanup, and then
remove these cores and install filter elements after cleanup.
Because of the larger system capacity, the pressure drop
through the temporarily installed cores will be somewhat larger
than normal, but still within the limits. After cleanup, the use of filter
elements will assure a minimum pressure drop when the system is
in normal operation. The low pressure drop through the filter
elements assures maximum energy savings during normal
operation. Cleanup of the system can be accomplished with either
the standard core (RC-10098) or the charcoal core
(RC-10098-HH).
SIGNIFICANCE OF THE PART NUMBER
The letters and numerals in the Catch-All part number each
have a significance. The C indicates Catch-All, and CW
indicates the High Water Capacity Catch-All. The FIRST TWO
OR THREE DIGITS indicate cubic inches of desiccant. The
LAST ONE OR TWO DIGITS indicate fitting size in eighths. For
sealed models, a -S following the last digit indicates solder
fittings, and NO LETTER indicates a flare fitting. Replaceable
core models (C-420 and larger) only have solder connections
and the -S is omitted.
Examples: C-083 is 8 cu. in. and 3/8 in. flare, C-309-S is 30 cu.
in. and 1-1/8 in. solder, C-19213 is 192 cu. in. and 1-5/8 in.
solder.
Other suffix letters indicate special qualities. For example:
-T indicates a pressure tap consisting of a Schrader type
access valve on the inlet end of the Catch-All.
-HH indicates a charcoal style core for wax removal and
cleanup after a hermetic motor burnout.
FILTER DRIERS
649
F
I
L
T
E
R
D
R
I
E
R
S
REPLACEABLE CORES AND PLEATED FILTER ELEMENTS
Cores for replaceable core type filter-driers are molded
with the same desiccants that are used in the popular
sealed filter-driers.
Cores are individually packed in metal cans, fully
activated and hermetically sealed against moisture and
dirt.
Filter elements are dried and packed in individuals
sealed metal cans. This method of packaging prevents
the element from picking up moisture from the
atmosphere
Each can contains a triple gasket consisting of a new
end plate gasket, an end plate gasket for certain
competitive filter-driers, and a core gasket where
desired. See the specifications on Page * for the number
of cores required for each type drier.
RC-4864 Activated Core Order as separate item
Fits types C-480 thru C-19200 Series Shells. This is the
standard core suitable for most installations in the liquid
or suction line.
RCW-48 High Water Capacity Core Order as
separate item Fits types C-480 thru C-19200 Series
shell. Designed specially for use with POE
lubricants. This core should be used on systems that
have a ruptured water cooled condenser, or that have
been exposed to the atmosphere, or for some reason
have a high amount of moisture in the system.
RC-4864-HH Activated Charcoal Core Order as
separate item Fits types C-480 thru C-19200 Series
Shells. This core should be used for wax removal, and
for clean-up of systems that have had a hermetic motor
burnout.
RPE-48-BD Filter Element Order as separate
item Fits types C-480 thru C-19200 Series
Shells and Replaceable Suction Filter (RSF)
Shells. This element should be used in RSF shells
installed in the suction line to obtain the lowest
possible pressure drop. In cleaning up a system
after a hermetic motor burnout, cores should be
used first. After clean-up, the filter element should
be installed.
RC-10098 Activated Core Order as a separate
item Fits types C-30,000 and C-40,000 Series
Shells. This is the standard core suitable for liquid
and suction line applications.
RCW-100 High Water Capacity Core Order
as separate item Fits types C-30,000 and C-
40,000 Series Shells. Designed specially for use
with POE lubricants. This core should be used on
systems that have a ruptured water cooled
condenser, or that have been exposed to the
atmosphere, or for some reason have a high
amount of moisture in the system.
RC-10098-HH Activated Charcoal Core Order
as separate item Fits types C-30,000 and C-
40,000 Series Shells. This core should be used for
wax removal, and for clean-up of systems that have
had a hermetic motor burnout.
RPE-100 Filter Element Order as separate
item Fits types C-30,000 and C-40,000 Series
Shells. This filter element should be used in the
suction line to obtain the lowest possible pressure
drop after cores were used for system clean-up.
HH STYLE CATCH-ALL FOR WAX REMOVAL
U.S. PATENT NUMBER 3,407,617
Small amounts of wax are often a problem on low temperature
systems. Even well engineered systems frequently contain
minute quantities of wax which are sufficient to clog expansion
valve screens or cause sticking of the valve. Sporlan has
developed a special blend of desiccants including activated
charcoal which removes small amounts of wax in the liquid line
before this wax can cause trouble at the expansion valve.
These Catch-All Filter Driers have been very successful in
correcting trouble jobs in the field.
By installing HH Style Catch-All Filter Driers in the liquid line of
all low temperature systems these wax problems can be
entirely prevented. In addition to their wax removal ability, these
filter driers will remove all of the other harmful contaminants
that the standard filter driers remove.
The following Catch-All Filter Driers are available with the HH
core to meet the needs of low temperature systems. For
dimensions, refer to the specifications for standard filter
driers or consult Bulletin 40-10.
PART NO.
CONNECTIONS
(in.)
PART NO.
CONNECTIONS
(in.)
C-052-HH 1/4 SAE Flare C-303-HH 3/8 SAE Flare
C-082-HH 1/4 SAE Flare C-304-HH 1/2 SAE Flare
C-083-HH 3/8 SAE Flare C-304-S-HH 1/2 ODF Solder
C-162-HH 1/4 SAE Flare C-305-HH 5/8 SAE Flare
C-163-HH 3/8 SAE Flare C-305-S-HH 5/8 ODF Solder
C-163-S-HH 3/8 ODF Solder C-414-HH 1/2 SAE Flare
C-164-HH 1/2 SAE Flare C-415-HH 5/8 SAE Flare
C-164-S-HH 1/2 ODF Solder C-417-S-HH 7/8 ODF Solder
C-165-HH 5/8 SAE Flare RC-4864-HH
C-165-S-HH 5/8 ODF Solder RC-10098-HH
Replaceable Core
FILTER DRIERS
650
F
I
L
T
E
R
D
R
I
E
R
S
REVERSIBLE HEAT PUMP FILTER-DRIER
DESIGN BENEFITS
A short overall length for easy installation.
Drier operates in either flow direction with low pressure drop.
Proven metal check valves used in construction no synthetic materials.
The Sporlan dependable molded core used for maximum filtration ability. When the flow
direction reverses, dirt already collected remains in the filter-drier.
A carefully engineered blend of desiccants for maximum water capacity and acid removal
ability. The HPC-160-HH Series also has the HH style core with activated charcoal which
offers maximum ability to remove oleoresin and other reactive chemical constituents in the oil.
Same rugged construction as used in the Catch-All.
SPECIFICATIONS -FOR NEW INSTALLATIONS AND HFC SYSTEM USE
Flow Capacity
Tons at 1 psi
P
Water Capacity
Dimensions
Refrigerant
Liquid Capacity
Ounces (Wt.)
@100F
R-22
Drops at 60 ppm
R-410A
Drops at 80 ppm*
Part No
Connection
Size Inches
Selection
Recommendations
Tons
Overall
Length
Inches
Diameter
Inches
R-22
R-410A
75F 125F 75F 125F
R-22
R-410A
HPC-103 3/8 Flare 6.75
HPC-103-S 3/8 Solder 5.88
3.4
3.3
HPC-104 1/2 Flare 6.94
HPC-104-S 1/2 Solder
1 thru 5
6.00
3.00
4.5
4.4
215
176
171
105
12.2
10.6
FOR CLEAN-UP AFTER BURNOUT
Dimensions
Water Capacity
Refrigerant 22
Drops at 60 ppm Part No
Connection
Size
Inches
Selection
Recommendations
Tons
Overall
Length
Inches
Diameter
Inches
Flow Capacity
R-22 Tons at 1
psi P
75F
125F
Liquid Capacity
Ounces (Wt.)
R-22 @ 100F
HPC-163-HH 3/8 Flare 1 thru 5 7.78 3.00 3.7 93 81 14.5
HPC-163-S-HH 3/8 Solder 1 thru 5 6.92 3.00 3.7 93 81 14.5
HPC-164-HH 1/2 Flare 1 thru 5 7.95 3.00 4.0 93 81 14.5
HPC-164-S-HH 1/2 Solder 1 thru 5 7.07 3.00 4.0 93 81 14.5
HPC-165-HH 5/8 Flare 1 thru 5 8.28 3.00 4.9 93 81 14.5
HPC-165-S-HH 5/8 Solder 1 thru 5 7.35 3.00 4.9 93 81 14.5
UL and ULc Listed Guide-SMGT-File No. SA-1756A & B. Core volume is 10 cubic inches for HPC-100 Series and 14 cubic inches for the
HPC-160-HH Series. Core surface filtering area is 18 sq. in. for the HPC-100 Series and 26 sq. in. for the HPC-160-HH Series. HPC-100
Series are rated for 650 psig; HPC-160-HH have a 500 psig rating.
*As of this printing, ARI has not established an EPD for R-410A.
FILTER DRIERS
651
F
I
L
T
E
R
D
R
I
E
R
S
SUCTION FILTER WITH THE EXCLUSIVE BI-DIRECTIONAL FEATURE
DESIGN BENEFITS
Protects the compressor from dirt
A relief device opens if the filter plugs
Suitable for use with all brazing alloys
Maximum corrosion resistance
Full flow design for low pressure drop
Complete line of sizes
Sporlan offers an exclusive concept in Suction Filter
design a filter which is Bi-directional. When flow is
in one direction, the bypass relief feature is active. If
the pressure drop across the element becomes
excessive the bypass relief will open slightly to
maintain sufficient gas flow and assure proper
cooling of the hermetic motor.
When the Suction Filter is installed
with flow in the opposite direction,
the bypass relief feature is inactive
and will never open, regardless of the
increase in pressure drop.
The -T in the part number indicates
that these models are equipped with
an access valve to permit pressure
drop readings. The access valve will
be operational provided the Suction
Filters are installed with the bypass
feature inactive.
SPECIFICATIONS
Types with bypass relief feature (Bi-directional Flow)
Part No Dimensions
WITHOUT Access
Valve
WITH Access Valve CONNECTIONS (in) FILTER AREA Sq In Overall Length Inches SOCKET DEPTH Inches SHELL DIAMETER
Inches
SF-283-F 3/8 SAE Flare 28 8.78 3.00
SF-285-T 5/8 ODF Solder 28 8.34 0.62 3.00
SF-286-T 3/4 ODF Solder 28 8.79 0.69 3.00
SF-287-T 7/8 ODF Solder 28 8.93 0.75 3.00
SF-289-T 1-1/8 ODF Solder 28 9.51 0.91 3.00
SF-489-T 1-1/8 ODF Solder 48 12.42 0.91 3.00
SF-4811-T 1-3/8 ODF Solder 48 13.10 0.97 3.00
SF-4813-T 1-5/8 ODF Solder 48 13.44 1.09 3.00
Types without bypass relief feature (Single Flow Direction)
Part No Dimensions
WITHOUT Access
Valve
WITH Access Valve CONNECTIONS (in) FILTER AREA Sq In Overall Length Inches SOCKET DEPTH Inches SHELL DIAMETER
Inches
SF-114 1/2 ODF Solder 11 4.36 0.50 2.00
SF-114-F 1/2 ODF Flare 11 5.25 2.00
SF-115 5/8 ODF Solder 11 4.60 0.62 2.00
SF-115-F 5/8 ODF Flare 11 5.56 2.00
SF-6417-T 2-1/8 ODF Solder 388 1094 1.24 4.75
SF-6421-T 2-5/8 ODF Solder 388 1094 1.38 4.75
SELECTION RECOMMENDATIONS
Part No NOMINAL SYSTEM HORSEPOWER* Refrigerant
WITHOUT Access Valve WITH Access Valve CONNECTIONS (in) 12, 134a, 404A, 502, 507 22, 407C
SF-114 1/2 ODF 1/2 1
SF-114-F 1/2 SAE 1/2 1
SF-115 5/8 ODF 1 2
SF-115-F 5/8 SAE 1 2
SF-283-F 3/8 SAE 1/2 1
SF-285-T 5/8 ODF 1-1/2 4
SF-286-T 3/4 ODF 1-1/2 5
SF-287-T 7/8 ODF 3 7-1/2
SF-289-T 1-1/8 ODF 5 7-1/2
SF-489-T 1-1/8 ODF 5 10
SF-4811-T 1-3/8 ODF 5 12
SF-4813-T 1-5/8 ODF 7 15
SF-6417-T 2-1/8 ODF 20 55
SF-6421-T 2-5/8 ODF 30 60
*Use R-502 horsepower recommendations for R-502A & B and R-508A.
Use R-12 horsepower recommendations for R-501A & B and R-509A. Ratings are in accordance with ARI Standard 730.
FILTER DRIERS
652
F
I
L
T
E
R
D
R
I
E
R
S
REPLACEMENT SUCTION FILTER
The Replaceable Suction Filter shell, used with RPE-48-BD pleated filter element, is designed to be
installed in the suction line of new systems to remove resident contaminants.
DESIGN BENEFITS:
Low pressure drop
Can be used with desiccant cores for clean-up after burnout
Various fitting sizes up to 3-1/89line size
Access valve supplied for pressure drop measurement or charging
HOW ITS USED Sporlan Replaceable Suction Filters are installed in the suction line of air conditioning
systems to remove contaminants that may be in the system at start-up. The Replaceable Suction Filter has
large fittings permitting the use of a small shell on a system with a large line size, resulting in considerable
economy. The angle construction is suitable for flow in either direction, which results in easy installation
even on compact racks. The Replaceable Suction Filters should be used with cores for cleaning up a
system after a hermetic motor burnout. Select the RC-4864, RC-4864-HH or RCW-48 replaceable cores.
After clean-up, install RPE-48-D elements in the shells.
SELECTION The table below gives information for choosing the proper model for a given system. The
filter elements are supplied in hermetically sealed metal cans.
SELECTION RECOMMENDATIONS WITH FILTER ELEMENTS
NOMINAL SYSTEM HORSEPOWER
Refrigerant
PART NO
CONNECTIONS
Inches
ODF Solder
12 & 134a 22 & 407C 404A, 502 & 507
NO. OF
FILTER
ELEMENTS
NO. OF CORES
OVERALL
LENGTH
Inches
RSF-487-T 7/8 7 10 10 9.30
RSF-489-T 1-1/8 8 15 12 9.37
RSF-4811-T 1-3/8 10 20 15 9.60
RSF-4813-T 1-5/8 12 25 20 9.60
RSF-4817-T 2-1/8 20 35 25 9.37
RSF-4821-T 2-5/8 25 50 35
One
RPE-48-BD
One
RC-4864
or
RC-4864-HH
9.75
RSF-9617-T 2-1/8 20 40 30 14.96
RSF-9621-T 2-5/8 30 50 40 15.43
RSF-9625-T 3-1/8 40 80 55
Two
RPE-48-BD
Two
RC-4864
or RC-4864-HH 15.12
Safety screen Part No.: 6171-S is required when cores are used in the RSF shell. Remove the screen when RPE-48-BD elements are used.
UL and ULc Listed Guide-SMGT-File No. SA-1756A & B.
ACID TEST KIT
PART NO
TA-1 One Time Acid Test Kit
FILTER DRIERS
653
M
O
I
S
T
U
R
E
A
N
D
L
I
Q
U
I
D
I
N
D
I
C
A
T
O
R
S
See -All Moisture and Liquid Indicators offers these 8 outstanding benefits
1. The SeeAll Moisture and Liquid Indicator provides a true
moisture indication for Refrigerants 12, 134a, 22, 404A, 407C, 410A,
502 and 507. The See All is also suitable for Refrigerants 401A & B,
402A & B, 408A and 409A. The dark green indicates dry and a bright
yellow indicates wet. The one indicator avoids the confusion found in
models with two elements. You cannot pick the wrong element when
checking the moisture content of the system.
2. RELIABLE and ACCURATELY CALIBRATED COLOR CHANGE
POINTS. The SeeAll Moisture and Liquid Indicator is accurately
calibrated in parts per million of moisture for each refrigerant. All
moisture indicators change color on the basis of relative saturation of
the refrigerant. Therefore, liquid line temperature must be considered
if an accurate calibration is to be obtained. A color chart is part of the
label, for easy comparison.
3. COLOR CHANGES ARE EASILY DISTINGUISHED and
REVERSIBLE. The indicators color differs so widely between WET
and DRY conditions that there is no possibility of confusion between
the two. Colors will reverse as often as moisture concentration in the
system changes.
4. LARGE FULL VIEW SIGHT GLASS. The SeeAll Moisture and
Liquid Indicator has an extra large crystal clear sight glass for
viewing the refrigerant. Bubbles indicate a shortage of refrigerant or a
restriction in the liquid line.
5. INDICATOR PROTECTED from DISCOLORATION and DIRT.
The indicator is protected by a filter pad and screen. This prevents
washing of the indicator by the refrigerant and protects it from system
contamination and turbulence.
6. REPLACEABLE INDICATOR ELEMENT. The color indicator
paper can be changed on the new fused glass models without
removing the SeeAll from the line. Replacement is thru the bottom
(see SA-14SU below). Request the K-SA-4 kit.
7. DISASSEMBLY OF THE SMALLER SIZES NOT REQUIRED.The
extended steel fittings on solder models in the smaller sizes make it
unnecessary to disassemble for installation since steel conducts onl
one eighth as much heat as copper.
8. A DOUBLE DUTY PLASTIC CAP is supplied to keep the glass
free from dust, dirt, and grease. It also permits the service engineer
to use his own discretion concerning instructions to his customers on
observing the SeeAll Moisture and Liquid Indicator.
Specifications
MALE FLARE
FEMALE & MALE
FLARE
MALE FLARE X
SWIVEL NUT
SWIVEL NUT X
SWIVEL NUT
FEMALE FLARE X
SWIVEL NUT
SWIVEL NUT X
ODF SOLDER
ODF SOLDER
CONNEC
-TION
SIZES
Inches
Part
No
Overall
Length
Inches
Part
No
Overall
Length
Inches
Part
No
Overall
Length
Inches
Part
No
Overall
Length
Inches
Part
No
Overall
Length
Inches
Part
No
Overall
Length
Inches
Part
No
Overall
Length
Inches
1/4 SA-12 2.87 SA-12FM 2.56 SA-12S
3/8 SA-13 3.37 SA-13FM 2.97 SA-13U 3.64 SA-13UU 3.95 SA-13UU 3.19 SA-13SU 4.19 SA-13S
4.62
1/2 SA-14 3.81 SA-14FM 3.44 SA-14U 4.13 SA-14UU 4.50 SA-14UU 3.75 SA-14SU 4.62 SA-14S
5/8 SA-15 4.13 SA-15U 4.44 SA-15UU 4.75 SA-15SU 4.89 SA-15S
4.87
7/8 SA-17S
1-1/8 SA-19S
6.31
1-3/8 SA-211
1-5/8 SA-213
2-1/8 SA-217
7.97
Listed by Underwriters Laboratories, Inc. - Guide SEYW - File No. SA3182
Maximum Rated Pressure 650 psi. Overall width is: 1.31 in. for 1/4 in. and 3/8 in. sizes, 1.58 in. for 1/2 in. and 5/8 in. sizes, and 1.38 in. for 7/8 in. and
1-1/8 in. sizes. Most solder connections can be used as male fittings as well as female fittings. The 1/4 in. ODF is 3/8 in. ODM, the 3/8 in. ODF is 1/2 in.
ODM, the 1/2 in. ODF is 5/8 in. ODM, and the 5/8 in. ODF is 3/4 in. ODM. Models with female flare and/or swivel nut connections are supplied with a copper
gasket in the fitting.
Moisture Content PPM
REFRIGERANT
12 22 134a 502 404A & 507 407C 410A SEEALL
SHOWS
LIQUID
LINE
TEMP
75 F 100 F 75 F 100 F 75 F 100 F 75 F 100 F 75 F 100 F 75 F 75 F
Green Dry Below 5 Below 10 Below 30 Below 45 Below 50 Below 80 Below 10 Below 20 Below 15 Below 30 Below 120 Below 75
Chartreuse CAUTION 5-15 10-30 30-90 45-130 50-200 80-225 10-45 20-65 15-90 30-140 120-280 75-150
Yellow WET
Above
15
Above
30
Above
90
Above
130
Above
200
Above
225
Above
45
Above
65
Above
90
Above
140
Above
280
Above
150
NOTE: Change or add Catch-All Filter-Drier when paper turns from green to chartreuse.
MOISTURE AND LIQUID INDICATORS
654
D
I
S
C
H
A
R
G
E
B
Y
P
A
S
S
V
A
L
V
E
S
SPORLAN DISCHARGE BYPASS VALVES
The Sporlan line of discharge bypass valves are designed to
provide an economical method of compressor capacity control
in place of cylinder Unloader or to handle unloading
requirements below the last step of cylinder unloading. These
modulating control valves automatically bypass the required
amount of discharge gas to the low side to maintain the
desired minimum evaporator pressure. The valves are
applicable on any refrigeration or air conditioning system that
operates during periods of low load, which can result in coil
icing or short cycling. These valves respond to downstream
pressure changes and open when the evaporator pressure
falls below the valve setting. At normal loads and evaporator
conditions, the valve remains closed and the system operates
in a conventional manner.
The DR line of valves consists of three basic types of valves:
the adjustable models, the adjustable remote bulb models, and
the non-adjustable models.
The SHGB valves are adjustable and pilot operated with a
solenoid stop feature that eliminates the need for a hot gas
solenoid valve. They were developed for use on larger
capacity systems.
APPLICATION The discharge bypass valve is normally
applied in a branch line off the discharge line. To allow system
pump down control, a solenoid valve or hand valve must be
installed upstream of the discharge DR type bypass valves.
The bypassed hot gas can enter the low side at several
locations; however, two of the possible locations are preferred
because of superior operating performance: into the side
connection of a Sporlan side connection distributor or directly
into the suction line. By using the side connection distributor
method, the system TEV will act as a desuperheating valve to
keep the compressor suction temperature below the
recommended maximum temperature published by the
compressor manufacturer. When the hot gas is bypassed
directly into the suction line, an auxiliary desuperheating TEV
may be required.
SELECTION and CAPACITY RATINGS The capacities
given in the table below are valve hot gas capacities and not
the capacities of the system on which the valve is to be applied.
To select a valve, first determine the compressor capacity at
the minimum allowable evaporating temperature.
Then the discharge bypass valve must supply the difference
between this compressor capacity and the minimum evaporator
load at which the system is to be operated. The valve pressure
setting will be that pressure at which the bypass valve must
start to open.
Connections (Standard Connections are in BOLD type).
ADRS(E)-2 3/8 in., 1/2 in., 5/8 in. ODF Solder or 3/8 in., 1/2
in., 5/8 in. SAE Flare
ADRP(E)-3 1/2 in., 5/8 in. ODF Solder on 1/2 in., 5/8 in. SAE
Flare
ADRHE-6 & DRHE-6 5/8 in., 7/8 in., 1-1/8 in. ODF Solder
SHGB(E)-8 7/8 in. ODF, 1-1/8 in. ODF Solder
SHGB(E)-15 1-1/8 in., 1-3/8 in. ODF Solder
Valves with ODF solder connections are supplied standard with
1/4 in. ODF external equalizer, 1/4 in. SAE Flare external
equalizer available on special order. Pilot operated models are
supplied with 1/4 in. SAE external equalizer.
DISCHARGE BYPASS VALVES
655
D
I
S
C
H
A
R
G
E
B
Y
P
A
S
S
V
A
L
V
E
S
SPORLAN DISCHARGE BYPASS VALVES
DISCHARGE BYPASS VALVE CAPACITIES Tons
Capacities based on 6 F evaporator temperature change from closed to rated opening (does not apply to pilot operated models),
discharge temperature 30 F above isentropic compression, 100 F condensing temperature, 0 F subcooling, 25 F superheat at
the compressor and includes both the hot gas bypassed and liquid refrigerant for desuperheating, regardless of whether the
liquid is fed through the system thermostatic expansion valve or auxiliary desuperheating thermostatic expansion valve.
VALVE TYPE & ADJUSTMENT RANGE (psig)
ADRI-1-1/4
ADRIE-1-1/4
ADRS-2
ADRSE-2
ADRP-3
ADRPE-3
ADRHE-6
DRHE-6
(Adjustable Remote Bulb Model)*
SHGB-8
SHGBE-8
SHGB-15
SHGBE-15
REFRIGERANT
MINIMUM
ALLOWABLE
EVAPORATOR
TEMPERATURE
0/55 0/75 0/100 0/30 0/80 0/30 0/80 0/30 0/80 25/35 32/44 55/70 65/80 0/100 0/75
40 0.58 0.53 3.51 5.99 9.16 1 9.8 15.7 58
26 0.44 0.64 0.54 3.57 6.26 9.90 1 6.9 15.9 62
0 0.63 0.60 0.49 3.90 3.66 7.38 6.61 13.9 10.9 16.2 66
22
20 0.59 0.50 0.44 3.75 3.65 7.45 6.64 14.1 11.0 16.2 69
40 0.40 0.43 0.34 2.67 4.94 9.34 9.64 10.9 41
26 0.41 0.39 0.32 2.60 2.44 4.95 4.42 9.36 7.26 8.31 10.9 43
134a
0 0.38 0.31 0.28 2.46 4.89 9.41 11.0 46
40 0.45 0.48 0.39 2.76 4.95 7.99 11.0 12.3 52
26 0.47 0.45 0.37 2.97 2.79 5.66 5.04 10.7 8.26 9.49 1 .4 52
401A
0 0.44 0.36 0.32 2.83 2.74 5.62 5.01 10.8 8.32 12.5 56
40 0.54 17.3
26 0.65 0.60 3.91 6.66 10.3 17.7 63
0 0.66 0.72 0.57 4.00 7.16 11.7 17.9 63
402A
20 0.69 0.63 0.52 4.22 4.04 8.11 7.33 15.3 12.2 18.0 64
40 0.55 17.5
26 0.67 0.60 3.91 6.70 10.4 21.4 17.7 64
0 0.67 0.71 0.56 4.00 7.16 11.7 17.9 65
404A
20 0.68 0.61 0.51 4.17 4.02 8.08 7.28 15.3 12.1 17.9 65
40 0.78 0.65 4.25 7.50 12.1 22.9 18.6 74
26 0.61 0.78 0.63 4.25 7.50 12.1 19.3 18.7 75
0 0.74 0.68 0.56 4.51 4.31 8.63 7.81 16.3 13.0 18.9 76
407C
20 0.68 0.56 0.50 4.33 4.23 8.64 7.71 16.5 12.9 19.1 77
40 0.46 3.14 5.28 7.85 19.2 14.3
26 0.56 0.49 3.19 5.51 8.55 16.6 14.5 55
0 0.55 0.57 0.46 3.58 3.28 6.64 5.90 12.5 9.62 14.7 59
502
20 0.55 0.59 0.41 3.43 3.30 6.68 6.00 12.6 9.91 14.8 61
40 0.53 17.4
26 0.65 0.59 3.87 6.60 10.2 17.7 64
0 0.71 0.57 3.96 7.09 11.5 17.8 64
507
20 0.69 0.62 0.52 4.17 4.00 8.02 7.25 15.2 12.0 17.9 65
PART NO DESCRIPTION
ADRS-20/30ODF ADRS-2 0/30 4 ODF
ADRS-20/305ODF ADRS-2 0/30 5 ODF
ADRSE-20/304ODF ADRSE-20/304ODF
ADRSE-20/305ODF ADRSE-20/305ODF
ADRS-20/804ODF ADRS-2 0/80 4 ODF
ADRS-20/805ODF ADRS-2 0/80 5 ODF
ADRSE-20/803ODF ADRSE-20/803ODF
ADRSE-20/804ODF ADRSE-20/804ODF
ADRSE-20/805ODF ADRSE-20/805ODF
ADRP-30/304ODF ADRP-3 0/30 4 ODF
ADRP-30/305ODF ADRP-3 0/30 5 ODF
ADRPE-30/304ODF ADRPE-30/304ODF
ADRPE-30/305ODF ADRPE-30/305ODF
ADRP-30/804ODF ADRP-3 0/80 4 ODF
ADRP-30/805ODF ADRP-3 0/80 5 ODF
ADRPE-30/804ODF ADRPE-30/804ODF
ADRPE-30/805ODF ADRPE-30/805ODF
ADRHE-60/305ODF ADRHE-60/305ODF
PART NO DESCRIPTION
ADRHE-60/805ODF ADRHE-6 0/80 5 ODF
ADRHE-60/807ODF ADRHE-6 0/80 7 ODF
ADRHE-60/809ODF ADRHE-6 0/80 9 ODF
DRHE-6-55/70AR7X7 DRHE-6-55/70AR 7 ODF
DRHE-6-55/70AR9X9 DRHE-6-55/70AR 9 ODF
SHGBE-8-0/1009ODF SHGBE-8-0/100 9 ODF LESS COIL
SHGBE-8-0/1007ODF SHGBE-8-0/100 7 ODF LESS COIL
SHGB-8-0/107ODF SHGB-8-0/100 7 ODF LESS COIL
SHGB-8-0/1009ODF SHGB-8-0/100 9 ODF LESS COIL
SHGB-15-0/759ODF SHGB-15-0/75 9 ODF LESS COIL
SHGB-15-0/7511ODF SHGB-15-0/75 11 ODF LESS COIL
SHGBE-15-0/759ODF SHGBE-15-0/75 9 ODF LESS COIL
SHGBE-15-0/7511 ODF SHGBE-15-0/75 11 ODF LESS COIL
DISCHARGE BYPASS VALVES
656
P
R
E
S
S
U
R
E
R
E
G
U
L
A
T
I
N
G
V
A
L
V
E
S
CRANKCASE PRESSURE REGULATING VALVES
Crankcase Pressure Regulating Valves are designed to
prevent overloading of the compressor motor by limiting
the crankcase pressure to a predetermined maximum
value during and after a defrost cycle or a normal
shutdown period. These valves automatically throttle the
vapor flow from the evaporator until the compressor can
handle the load.
Sporlan manufactures five adjustable models
CRO-4, CRO-6, CROT-6, CRO-10 and
CROT-10all models respond only to their outlet
pressure and modulate to prevent the suction pressure
at the compressor from rising above the valve setting.
Since these valves are adjustable, the setting may be
altered to suit the specific system requirements.
SELECTION and CAPACITY RATINGS
The ratings for these valves vary depending on three
items: design suction pressure after pull down, maximum
allowable suction pressure recommended by the
compressor or unit manufacturer (this is the valve
setting), and pressure drop across the valve. The
difference between the design suction pressure and the
valve setting determines how much of the valve stroke is
used. Therefore, the valve setting should be kept as high
as possible without exceeding the recommendation of
the compressor or unit manufacturer.
PART NO* SPORLAN MODEL
CRO-4-0/20 4X4 ODF LS
CROT-10 30/110 9 ODF WS
CROT-10 30/110 11 ODF WS
CROT-10 0/6011ODF WS
CROT-10 0/60 1-1/8"ODF
CROT-10 0/60 7 ODF WS
CROT-10 30/110 7 ODF WS
CROT-12-65/225 9 ODF
CROT-15-65/225 11 ODF
CROT-6 0/60 5 ODF WS
CROT-6 0/60 1/2" SAE
CROT-6 0/60 5/8" SAE
CROT-6 0/60 7 ODF WS
CROT-6 30/110 5 ODF WS
CROT-6 30/110 7 ODF WS
*( ) Please contact your local Carlyle Certified Refrigeration
Partner or RCD Customer Service for P/N and Pricing.
HEAD PRESSURE CONTROL VALVES
Sporlan Head Pressure Control for systems with air cooled condensers
can be accomplished with several valve types or combinations. The
valve types are: LAC-4, OROA-5, LAC-5, LAC-10, ORI/ORD
combination and the ORIT/CROT combination.
The LAC, OROA, ORI and ORIT are designed for application in
the liquid line and should not be applied in the discharge line for
any reason. Compressor pulsations can greatly shorten the life
of the valves. If any of the valves are applied in any manner
other than described here, the Sporlan warranty is void.
PART NO* SPORLAN MODEL
ORD-4-20 5/8 ODF
ORD-4-20 7/8 ODF
ORD-4-25 5/8 ODF
ORD-4-30 5/8 ODF
ORD-4-35 5/8 ODF
ORI-10 65/225 1-1/8"
ORI-10 65/225 1-3/8"
ORI-10 65/225H 7ODF WS
ORI-10 65/225H 11 ODF WS
ORI-6 65/225 5/8" WS
ORI-6 0/50 5 ODF WS
ORI-6 65/225 7/8" WS
ORI-6 65/225H 9ODF WS
ORIT-15-65/225 11 ODF
ORIT-20-65/225 13 ODF
PART NO* SPORLAN MODEL
OROA-5-100 5/8 ODF WS
OROA-5-100 7/8 ODF WS
OROA-5-150 7/8 ODF WS
OROA-5-180 5/8 ODF WS
OROA-5-180 7/8 ODF WS
OROA-5-220 5/8 ODF WS
IMPORTANT NOTES: WS - With Strainer
LS - Less Strainer
PART NO* SPORLAN MODEL
LAC-10-100 11X7 ODF LS
LAC-10-100 11X9 ODF LS
LAC-4-100 1/2 ODF LS
LAC-4-180 3/8 0DF LS
LAC-4-190 1/2 ODF LS
LAC-4-210 1/2 ODF LS
LAC-4-240 1/2 ODF LS
LAC-5-100 1-1/8 ODF LS
LAC-5-210 5/8 ODF WS
LAC-5-75 1/2 ODF LS
PART NO* SPORLAN MODEL
CROT-12-65/225 9 ODF
CROT-15-65/225 11ODF
*( ) Please contact your local Carlyle Certified Refrigeration Partner or RCD Customer Service for P/N and Pricing.
PRESSURE REGULATING VALVES
657
P
R
E
S
S
U
R
E
R
E
G
U
L
A
T
I
N
G
V
A
L
V
E
S
DEFROST DIFFERENTIAL PRESSURE REGULATING VALVES
ADJUSTMENT RANGE AND PRESSURE
SETTINGS
All defrost differential valves are set by turning
the adjusting stem located under the cap on
the pilot differential valve.
The adjustment range is 5 to 50 psig. The
(O)LDR has a factory setting of 18 psid and
the DDR-20 has a factory setting of 30 psid.
Turning the stem clockwise increases the
setting, counterclockwise decreases
the setting.
DDR-20 VALVE OPERATION
The DDR-20 is designed to create a differential
pressure between its inlet (discharge) pressure and the
receiver pressure.
A solenoid bypass feature is incorporated in the valve
so that the valve can be made to go full open when
there is no need for a differential to be created.
Energizing the solenoid coil opens the valve fully.
LOCATION
The (O)LDR valve is located between the receiver and
the liquid header. The DDR-20 is located in the
discharge line before the condenser.
PART
NO*
SPORLAN MODEL
OLDR-15 11ODF LESS COIL
OLDR-15 9ODF LESS COIL
OLDR-20 13ODF LESS COIL
OLDR-20 17ODF LESS COIL
DDR-20 13 ODF LESS COIL
*( ) Please contact your local Carlyle Certified Refrigeration Partner or RCD Customer Service for P/N and Pricing.
EVAPORATOR PRESSURE REGULATING VALVES
The Sporlan line of evaporator pressure regulating
(EPR) valves are designed to provide an accurate and
economical means of balancing system capacity and
load requirements during low loads and/or while
maintaining different evaporator conditions on multi-
temperature evaporator systems. These valves control
evaporator temperature by maintaining evaporator
pressure. As the evaporator load increases the ORI
valves will Open on Rise of I nlet pressure above the
valves setting to provide more flow capacity to meet the
evaporator load. When the evaporator load decreases
the valves will modulate closed to maintain the pressure
setting of the valve.
Sporlan offers a number of EPR valve types in various
sizes, and with optional features to accommodate
almost any industry requirement. For more complete
information on any of the EPR valve types see your
Sporlan Wholesaler or contact your Sporlan Sales
Engineer.
APPLICATIONS
Maintain minimum evaporator temperature to avoid
frost on air coils and provide improved humidity control
Evaporator temperature control for food merchandisers
(single and multiple evaporator systems)
Evaporator temperature control on water chilling units
PART
NO*
SPORLAN MODEL
PART
NO*
SPORLAN MODEL
ORI-6 0/50 5 ODF WS
SORIT-12 0/100 208-240VAC 9ODF
ORIT-10 0/50 7 ODF WS
SORIT-12-0/100 LC 9ODF
ORIT-10 0/50 11 ODF WS
SORIT-15-0/100 LC 11ODF
ORIT-10 0/50 9 ODF WS
SORIT-20-0/100 LC 13ODF
ORIT-10 30/100 7 ODF WS
SORIT-PI-211S-0/100 LC
ORIT-10 30/100 9 ODF WS
SORIT-PI-25S-0/100 LESS COIL
ORIT-10 30/100 11 ODF WS
SORIT-PI-25SE-0/100 LESS COIL
ORIT-12 0/100 9 ODF
SORIT-PI-27S-0/100 LESS COIL
ORIT-15 0/100 11 ODF
SORIT-PI-27SE-0/100 LESS COIL
ORIT-20 0/100 13 ODF
SORIT-PI-29S-0/100 LESS COIL
ORIT-6 0/50 5/8" SAE
SORIT-PI-29SE-0/100 LESS COIL
ORIT-6 0/50 1/2" SAE
SORIT-PI-311S-0/100 LESS COIL
ORIT-6 0/50 5 ODF WS
SORIT-PI-313S-0/100 LESS COIL
ORIT-6 0/50 7 ODF WS
SORIT-PI-37S-0/100 LESS COIL
ORIT-6 30/100 5 ODF WS
SORIT-PI-39S-0/100 LESS COIL
ORIT-6 30/100 7 ODF WS
SORIT-PI-411S-0/100 LESS COIL
ORIT-PI-25-0/100
SORIT-PI-413S-0/100 LESS COIL
ORIT-PI-27-0/100
SORIT-PI-417S-0/100 LESS COIL
ORIT-PI-29-0/100
SORIT-PI-49S-0/100 LESS COIL
ORIT-PI-311-0/100
SORIT-PI-511S-0/100 LESS COIL
ORIT-PI-39-0/100
SORIT-PI-513S-0/100 LESS COIL
ORIT-PI-411-0/100
SORIT-PI-517S-0/100 LESS COIL
ORIT-PI-413-0/100
ORIT-PI-513-0/100
IMPORTANT NOTES:WS - With Strainer
*( ) Please contact your local Carlyle Certified Refrigeration Partner or RCD
Customer Service for P/N and Pricing.
PRESSURE REGULATING VALVES
658
E
L
E
C
T
R
O
N
I
C
T
E
M
P
C
O
N
T
R
O
L
S
Y
S
T
E
M
S
/
O
I
L
F
I
L
T
E
R
S
ELECTRONIC TEMPERATURE CONTROL SYSTEMS
Type CDS-9 and CDS-16
PART NO* SPORLAN MODEL
CDS-16 11ODF 10'-S ST
CDS-16 11ODF 20'-S ST
CDS-9 7ODF 20'-H
CDS-9 9ODF 20'-S
*( ) Please contact your local Carlyle Certified Refrigeration
Partner or RCD Customer Service for P/N and
Pr icing.
SERIES OIL FILTER
DESIGN BENEFITS
Virtually eliminates the need for oil changes due to
suspended particulate in circulation
Unsurpassed filtering efficiency
99% removal of 3 micron sized particles
98% removal of 2 micron sized particles
Element utilizes a pleated design for maximum
surface area
Unsurpassed filtration capacities ESIGN BENEFITS
High flow capacities with
low pressure drop
Filter element utilizes an
O-ring seal
Inert micro glass filter
material insures lubricant
compatibility
Dimensions allow for easy
replacement of current filter
The Sporlan Catch-All or SF-283-F Suction Filter has been
used for many years as an oil filter in refrigeration rack systems
with mineral or alkylbenzene as the lubricant of choice.
With the use of the new polyolester (POE) oils, system
chemistry has changed. Unlike mineral and alkylbenzene oils,
POE oil has solvent like tendencies. POE oil has the ability to
suspend and recirculate small, solid contaminants left from
system installation or retrofit. Analysis of POE oil samples
taken from actual systems have shown the oil to suspend and
recirculate a high concentration of 2-20 micron sized particles,
with the largest percentage between 2-10 microns. Although
some particles are smaller than bearing tolerances, studies
have shown bearing life can still be affected.
Bearing wear depends upon the size, hardness, and
concentration of particles in circulation. To effectively remove
these small particles, Sporlan developed a new type of oil filter.
The OF Series Oil Filters are designed to be 99% efficient in
removing 3 micron sized particles and yet have sufficient flow
capacity at a low pressure drop. The unsurpassed filtration
ability of the oil filters will assure clean POE, mineral, or
alkylbenzene oil is returned to the compressors. Clean oil
insures proper operation of the oil level control and minimizes
compressor wear. The Sporlan OF Series Oil Filters were
designed to virtually eliminate the need for oil changes
resulting from suspended solid contaminants in circulation.
PART NO* SPORLAN MODEL
OF-303 OIL FILTER
OF-303-T OIL FILTER
OF-303-BP OIL FILTER
ROF-413-T REPLACEABLE FILTER
OFE-1 OIL FILTER ELEMENT
*( ) Please contact your local Carlyle Certified Refrigeration Partner or
RCD Customer Service for P/N and Pricing.
ELECTRONIC TEMP CONTROL SYSTEMS/OIL FILTERS
659
O
I
L
L
E
V
E
L
C
O
N
T
R
O
L
S
Y
S
T
E
M
OIL LEVEL CONTROL SYSTEM
The OCV will only relieve pressure from the
reservoir in excess of its fixed set point.
Systems with fluctuating suction pressure as a
result of compressor unlades, staging or other
suction line controls must be fitted with an OCV
with a differential greater than the suction
pressure fluctuation to assure oil flow from the
OR-1-1/2 through the oil level control to the
compressor crankcase.
Sporlan offers OCVs with a 5, 10,
and 20 psi fixed differential setting.
However, Sporlan recommends the use of an
OCV-20 on all field built
up applications.
OIL LEVEL CONTROLS
The purpose of the Sporlan Oil Level Control is
to regulate the flow of oil to the compressor
crankcase to maintain a minimum oil level as
specified by the compressor manufacturer for
any given application.
Sporrans Oil Level Control System Components were
developed to offer the refrigeration industry an oil level
control system of the highest quality. The heart of the
system is the Oil Level Control which when matched
with the Oil Reservoir and Oil Differential Check Valve
maintains a minimum oil level in the compressor
crankcase during all phases of system operation.
OIL RESERVOIR Type OR-1-1/2
The Sporlan Oil Reservoir (OR-1-1/2) is a holding vessel
to contain the oil that is not within the crankcase, the oil
separator, or in circulation. The OR-1-1/2 has an inlet
and an outlet service valve so it may be isolated from
the rest of the system, or the oil supply from the oil
reservoir to the Oil Level Control can be eliminated for
service. The OR-1-1/2 also contains two sight glasses
so the maximum and minimum oil level can be
observed. The sight glasses are placed on the shell
symmetrically so 1/4 gallon of oil is contained between
the lower sight glass and the bottom of the shell; 1
gallon is contained between the sight glasses; and 1/4
gallon is contained between the upper sight glass and
the top of the shell. This allows the shell to be mounted
vertically with either service valve on top. Depending on
which end of the OR-1-1/2 Oil Reservoir is mounted to
the top, the oil service valves will be pointing either right
or left for piping convenience.
OIL DIFFERENTIAL CHECK VALVE
Types OCV-5, OCV-10, OCV-20
The Sporlan Oil Level Differential Check Valve (OCV) is
installed on the 3/8 SAE fitting on top of the OR-1-1/2,
and allows pressure to be relieved from the reservoir to
the suction as required to maintain a pressure in the
reservoir at a preset level above the suction pressure.
The pressure differential created by the OCV assures oil
flow from the reservoir to the Oil Level Control providing
there is adequate oil in the reservoir.
NOTE: OL-60CH replaces OL-1CH and OL-2CH;
OL-60FH replaces OL-1FH and OL-2FH models.
PART NO* SPORLAN MODEL
OL-60CH OIL LEVEL CONTROL
OL-60FH OIL LEVEL CONTROL
OL-60XH OIL LEVEL CONTROL
OR-1-1/2 OIL RESERVOIR
OCV-10 CHECK VALVE
OCV-20 CHECK VALVE
OCV-30 CHECK VALVE
OCV-5 CHECK VALVE
S-OL OIL LEVEL SIGHT GLASS KIT
AOL-A COPELAND ADAPTOR
AOL-K-1 ADAPTOR KIT -OM-1
AOL-R-1 KIT
*( ) Please contact your local Carlyle Certified Refrigeration Partner or RCD
Customer Service for P/N and Pricing.
TEMPERATURE RESPONSIVE MISCELLANEOUS VALVES, REPLACEMENT PARTS, PARTS
KITS, SOLENOID COILS, AND STRAINER
PART
NO*
SPORLAN MODEL
ADRHE-60/307 ODF
ADRHE-60/309 ODF
ADRIE-1-1/4-0/55 3X3 ODF ST
ADRIE-1-1/4-0/75 3X3 ODF ST
825-005 INLET STRAINER 5/8 ODF
825-007 INLET STRAINER 7/8 ODF
825-009 INLET STR 1-1/8 ODF
825-011 INLET STR 1-3/8 ODF
877-003 INLET STRAINER 3/8 ODF
877-004 INLET STRAINER 1/2 ODF
6034 Y-TYPE 1/2 FPT STRAINER
PART
NO*
SPORLAN MODEL
K-PI-E KIT
RK-SORIT-PI-2 0/100
RK-SORIT-PI-3 0/100
RK-SORIT-PI-4 0/100
KS-12DB
KS-12DC
KS-16DB
KS-ORI/CDA-15 INT PARTS KIT
KS-ORI/CDA-20 INT PARTS KIT
K-SORIT-PI KIT
K-Y1005-1 0/100 PILOT ASSY KIT
OMKC-2 120/50-60 JAM
OMKC-2 208-240/50-60 JAN
PART
NO*
SPORLAN MODEL
Y 1037-FV-1-1/2-190 3VX3 ODF 5
Y 1037-FV-1-190 3VX3 ODF 30
Y 1037-FV-2-190 3VX3 ODF 5
Y 1037-FV-3-190 3VX3 ODF 5
Y 1037-FV-5-190 3VX3 ODF 5
Y 1037-FV-1/2-190 3VX3 ODF 5
Y 1037-FV-1/2-220 3VX3 ODF 5
Y 1037-FV-1/2-230 3VX3 ODF 5
Y 1037-FV-1/2-250 3VX3 ODF 5
Y 1037-FV-1/3-190 3VX3 ODF 5
Y 1037-FV-1-1/2-220 3VX3 ODF 5
Y 1037-FV-1-1/2-230 3VX3 ODF 5
Y 1037-FV-1-1/2-250 3VX3 ODF 5
Y 1037-FV-1-220 3VX3 ODF 5
Y 1037-FV-1-230 3VX3 ODF 5
Y 1037-FV-1-250 3VX3 ODF 5
* ( ) Please contact your local Carlyle Certified Refrigeration Partner or RCD Customer Service for P/N and Pricing.
OIL LEVEL CONTROL SYSTEM
660
M
I
S
C
E
L
L
A
N
E
O
U
S
PART
NO*
SPORLAN MODEL
ADRHE-60/307 ODF
ADRHE-60/309 ODF
ADRIE-1-1/4-0/55 3X3 ODF ST
ADRIE-1-1/4-0/75 3X3 ODF ST
825-005 INLET STRAINER 5/8 ODF
825-007 INLET STRAINER 7/8 ODF
825-009 INLET STR 1-1/8 ODF
825-011 INLET STR 1-3/8 ODF
877-003 INLET STRAINER 3/8 ODF
877-004 INLET STRAINER 1/2 ODF
PART
NO*
SPORLAN MODEL
K-PI-E KIT
RK-SORIT-PI-2 0/100
RK-SORIT-PI-3 0/100
RK-SORIT-PI-4 0/100
KS-12DB
KS-12DC
KS-16DB
KS-ORI/CDA-15 INT PARTS KIT
KS-ORI/CDA-20 INT PARTS KIT
K-SORIT-PI KIT
K-Y1005-1 0/100 PILOT ASSY KIT
PART
NO*
SPORLAN MODEL
MKC-1 120/50-60 JAM
MKC-1 208-240/50-60 JAN
MKC-1 24/50-60 JAQ
MKC-1-DUAL/50-60 JAU
MKC-2 24/50-60 JAQ
MKC-2 120/50-60 JAM
MKC-2 208-240/50-60 JAN
MKC-2-DUAL/50-60 JAU
OMKC-2 120/50-60 JAM
OMKC-2 208-240/50-60 JAN
6034 Y-TYPE 1/2 FPT STRAINER
* ( ) Please contact your local Carlyle Certified Refrigeration Partner or RCD Customer Service for P/N and Pricing.
MISCELLANEOUS
661