V28
(ATTACHMENT) TEST RESULT
571.118 Standard No. 118; Power-operated window, partition and roof panel systems.
ITEM
REQUIREMENT
TEST RESULT
PASS/FAIL
Operating requirements.
S4.
Except as provided in S5, power operated window, partition, or roof panel
PASS
systems may be closed only in the following circumstances:
(a)
When the key that controls activation of the vehicle's engine is in the "ON",
OK
PASS
"START", or "ACCESSORY" position;
(b)
By muscular force unassisted by vehicle supplied power;
N/A
(c)
Upon continous activation by a locking system on the exterior of the vehicle;
N/A
(d)
Upon continous activation of a remote actuation device, provided that the
N/A
OK
PASS
N/A
N/A
remote actuation device shall be incapable of closing the power window,
partition or roof panel from a distance of more than 6 meters from the vehicle;
(e)
During the interval between the time the locking device which controls the
activation of the vehicle's engine is turned off and the opening of either of
a two-door vehicle's doors or, in the case of a vehicle with more than two doors,
the opening of either of its front doors;
If the window, partition, or roof panel is in a static position before starting to
(f)
close and in that position creates an opening so small that a 4mm diameter
semi-rigid cylindrical rod cannot be placed through the opening at any location
arround its edge in the manner described in S5(b); or
(g)
Upon continous activation of a remote actuation device, provided that the
remote actuation device shall be incapable of closing the power window,
partition or roof panel if the device and the vehicle are separated by
an opaque surfaceand provided that the remote actuation device shall be
incapable of closing the power window, partition or roof panel from
a distance of more than 11meters from the vehicle.
/ (HeeTae Yang) / 2015-09-07 10:00/ , .
ITEM
REQUIREMENT
TEST RESULT
PASS/FAIL
Automatic reversal systems.
S5.
A power operated window, partition, or roof panel systems that is capable of
N/A
closing or of being closed under any circumstances other than those specified
in S4 shall be meet the requirements of S5.1, S5.2, and, if applicable, S5.3.
While closing, the power-operated window, partition, or roof panel shall stop
S5.1.
and reverse direction either before contacting a test rod with properties
described in S8.2 orS8.3, or before exerting a squeezing force of 100newtons(N)
or more on a semi-rigid cylindrical test rod with the properties described
in S8.1, when such test rod is placed through the window, partition, or
roof panel opening at any location in the manner described in the
applicable test under S7.
Upon reversal, the power-operated window, partition, or roof panel system
S5.2.
must open to one of the following positions, at the manufacturer's option:
(a)
A position that is at least as open as the position at the time closing was
initiated;
(b)
A position that is not less than 125milimeters(mm) more open than the position
at the time the window reversed direction; or
(c)
A position that permits a semi-rigid cylindrical rod that is 200mm in diameter
to be placed through the opening at the same location as the rod described in
S7.1 or S7.2(b)
S5.3.
If a vehicle uses proximity detection by infrared reflection to stop and reverse a
power-operated window, partition, or roof panel, the infrared source shall
project infrared light at a wavelength of not less than 850nm and not
more than 1050nm.
The system shall meet the requirements in S5.1 and S5.2 in all ambient light
conditions from total darkness to 65,000 lux (6,000 foot candles) incandescent
light intensity.
/ (HeeTae Yang) / 2015-09-07 10:00/ , .
ITEM
REQUIREMENT
TEST RESULT
PASS/FAIL
Actuation Devices.
S6.
Except as provided in paragraph S6(b), actuation devices in the occupant
PASS
compartments of vehicles used to close power-operated windows, partitions,
and roof panels must meet the following requirements:
(a)
An actuation device must not cause a window, partition, or roof panel to
OK
PASS
N/A
OK
PASS
begin to close from any open position when tested as follows:
(1) Using a stainless steel sphere having a surface finish between
8 and 4 micro inches and a radius of 20mm0.2mm, place the surface
of the sphere against any position of the actuation device.
(2) Apply a force not to exceed 135 Newtons(30 pounds) through the geometric
center of the sphere. This force may be applied at any angle with respect to
the actuation device.
(3) For actuation devices that cannot be contact by the sphere specified in S6(a)(1)
prior to the application of force, apply a force up to the level specified in S6(a)(2)
at any angle in an attempt to make contact with the actuation device.
The sphere is directionally applied in such a manner that, if unimpeded, it
would make contact with the actuation device.
(b)
The requirement in S6(a) does not apply to either(1) actuation devices that are mounted in a vehicle's roof, headliner, or overhead
console that can close power-operated windows, partitions, or roof panels
only by continuous rather than momentary switch actuation, or
(2) actuation devices for closing power-operated windows, partitions, or roof
panels which comply with paragraph S5.
(c)
Any actuation device for closing a power-operated window must operate
by pulling away from the surface in the vehicle on which the device is mounted.
(Window Only)
An actuation device must operate only when pulled vertically up (if horizontally
mounted), or out (if vertically mounted), or in a direction perpendicular to the
surrrounding surface if mounted in a sloped orientation, in order to cause
the widndow to move in the closing direction.
/ (HeeTae Yang) / 2015-09-07 10:00/ , .
DATA SHEETS
FMVSS 118
COMPLIANCE DATA SUMMARY SHEET
PASS
FAIL
NOT
APPLICABLE
S4
Intetior Locking System in Off Position(s)
S4
Intetior Locking System With Key Removed
S4
Extetior Locking System
S4
Remote Actuation Device
REQUIREMENT
S6
Occupant Compartment Actuation Devices
(Sphere Test/Pull Up or Pull Out Test)
S5
Automatic Reversal System
REMARKS: The power operated window and roof systems comply with S4/S6, so it don't need to be satisfactory with S5
LEFT
FRONT
LEFT
REAR
RIGHT
FRONT
RIGHT
REAR
TAIL
GATE
PARTITIO
N
ROOF
PANEL
Power WPRP Installed
N/A
N/A
Individual Interior Actuation Devices
N/A
N/A
Master Control Panel Actuation
Devices
N/A
N/A
N/A
WPRP Operaed by Exterior
Locking System
N/A
N/A
N/A
N/A
N/A
N/A
N/A
WPRP Operaed by Remote
Control
N/A
N/A
N/A
N/A
N/A
N/A
N/A
WPRP with Auto-Reverse
Control
N/A
N/A
N/A
N/A
N/A
WPRP with Express-Up Capability
N/A
N/A
N/A
N/A
N/A
Master Control Panel Location: Left Front
Exterior Locking System Location: N/A
/ (HeeTae Yang) / 2015-09-07 10:00/ , .
Remote Control Type: N/A
)Line-of-Sight
)Non-line-of-Sight:
WPRP Actuation Device Design [Toggle, Rocker, Push/Pull(Lever), or describe other]:
Master Control Panel : Push/Pull
Individual Window : Push/Pull
Roof Panel : Push/Pull/Toggle
Partition : N/A
Interior Locking System Key Positions (clockwise): Clockwise
All WPRP open/close cycles are satisfactory with key in "ON" position:
( O ) YES
) NO
If NO, Compliance test shall not proceed.
All WPRP open/close cycles are satisfactory with key in "ACCESSORY" position:
(
) YES
( O ) NotApplicable - NO power to WPRPs
Key lock position at start of test execution.
( O ) ON
Key lock off position dusing test execution.
ACTUATION DEVICE
) LOCK
) ACCESSORY
( O ) OFF
LEFT DOOR
OPEN
DOORS CLOSED
INOP.
OPER.
INOP.
OPER.
) OTHER
RIGHT DOOR
OPEN
INOP.
PASS/FAIL
OPER.
MASTER CONTROL PANEL ACTUATION DEVICES
Left Front (LF)
PASS
Right Front (RF)
PASS
Left Rear (LR)
PASS
Right Rear (RR)
PASS
Tail Gate (TG)
N/A
N/A
N/A
N/A
Vent Window (s)
N/A
N/A
N/A
N/A
Partition (P)
N/A
N/A
N/A
N/A
Roof Panel (RP)
PASS
INDIVIDUAL ACTUATION DEVICES
Left Front (LF)
PASS
Right Front (RF)
PASS
Left Rear (LR)
PASS
Right Rear (RR)
PASS
Tail Gate (TG)
N/A
N/A
N/A
N/A
Vent Window (s)
N/A
N/A
N/A
N/A
Partition (P)
N/A
N/A
N/A
N/A
Roof Panel (RP)
PASS
/ (HeeTae Yang) / 2015-09-07 10:00/ , .
Key lock position at start of test execution.
( O ) ON
) ACCESSORY
LEFT DOOR
OPEN
DOORS CLOSED
ACTUATION DEVICE
INOP.
OPER.
INOP.
OPER.
RIGHT DOOR
OPEN
INOP.
PASS/FAIL
OPER.
MASTER CONTROL PANEL ACTUATION DEVICES
Left Front (LF)
PASS
Right Front (RF)
PASS
Left Rear (LR)
PASS
Right Rear (RR)
PASS
Tail Gate (TG)
N/A
N/A
N/A
N/A
Vent Window (s)
N/A
N/A
N/A
N/A
Partition (P)
N/A
N/A
N/A
N/A
Roof Panel (RP)
PASS
INDIVIDUAL ACTUATION DEVICES
Left Front (LF)
PASS
Right Front (RF)
PASS
Left Rear (LR)
PASS
Right Rear (RR)
PASS
Tail Gate (TG)
N/A
N/A
N/A
N/A
Vent Window (s)
N/A
N/A
N/A
N/A
Partition (P)
N/A
N/A
N/A
N/A
Roof Panel (RP)
PASS
Sphere Test
/ (HeeTae Yang) / 2015-09-07 10:00/ , .
ACTUATION DEVICE
APPLICABLE
(YES/NO) *
SPHERE ACTIVATED
ACTUATION DEVICE
CLOSES WPRP
(YES/NO)
TEST RESULT
(PASS/FAIL)
COMPLIANCE
REQUIRED
(Y/N) **
MASTER CONTROL PANEL ACTUATION DEVICES
Left Front (LF)
YES
NO
PASS
Right Front (RF)
YES
NO
PASS
Left Rear (LR)
YES
NO
PASS
Right Rear (RR)
YES
NO
PASS
Tail Gate (TG)
N/A
N/A
N/A
N/A
Vent Window (s)
N/A
N/A
N/A
N/A
Partition (P)
N/A
N/A
N/A
N/A
Roof Panel (RP)
YES
NO
PASS
INDIVIDUAL ACTUATION DEVICES
Left Front (LF)
YES
NO
PASS
Right Front (RF)
YES
NO
PASS
Left Rear (LR)
YES
NO
PASS
Right Rear (RR)
YES
NO
PASS
Tail Gate (TG)
N/A
N/A
N/A
N/A
Vent Window (s)
N/A
N/A
N/A
N/A
Partition (P)
N/A
N/A
N/A
N/A
Roof Panel (RP)
YES
NO
PASS
* This requirement does not apply to actuation devices that are mounted in a vehicle's roof, headliner, or overhead
console and that can close a window, partition, or roof panel only by continuous rather than momentary
switch actuation, or actuation devices that comply with the reversing requirements of FMVSS 118, S5.
** Requirement is effective 1 October 2008. Early compliance is voluntary and test results are used for information only
ACTUATION DEVICE
Switch Orientation
a. Horizontal
b. Vertical
c. Angled
Closes poweroperated window
ONLY IF :
Pull up or Pull out
TEST RESULT
(PASS/FAIL)
COMPLIANCE
REQUIRED
(Y/N) **
MASTER CONTROL PANEL ACTUATION DEVICES
Left Front (LF)
Pull Up
PASS
Right Front (RF)
Pull Up
PASS
Left Rear (LR)
Pull Up
PASS
Right Rear (RR)
Pull Up
PASS
Vent Window (s)
N/A
N/A
N/A
N/A
INDIVIDUAL ACTUATION DEVICES
Left Front (LF)
Pull Up
PASS
Right Front (RF)
Pull Up
PASS
Left Rear (LR)
Pull Up
PASS
Right Rear (RR)
Pull Up
PASS
Vent Window (s)
N/A
N/A
N/A
N/A
** Requirement is effective 1 October 2008. Early compliance is voluntary and test results are used for information only
/ (HeeTae Yang) / 2015-09-07 10:00/ , .
V28
Power window, partition, roof panel
FMVSS
118
S4
1. Key ON, START, or ACCESSORY
2.
3. Key Locking System
4. (6m
)
5. E/G Frt Door
6. 4mm
7. . ,
.
-
- 11m .
Power window S4
1. 4-200mm ,
100N
FMVSS
118
S4
-
2.
S5
125mm
200mm
FMVSS
118
FMVSS
118
FMVSS
118
S5
S6
S6
2008. 10. 1 :
( )
2008. 10. 1 : Power window, partition, roof
panel S/W
1. 8~4 micro inch 20 mm 0.2 mm
, ,
,
135N(30
lbs)
2.
roof,
headliner
overhead
console
, (, one touch
auto-close type )
,
2010. 10. 1 : Power-operated window
/ (HeeTae Yang) / 2015-09-07 10:00/ , .
1.
V28
2.
1) : 202mm
( : X, : O)
0 ~ 20N
OK
20 ~ 40N
OK
40 ~ 60N
OK
60~ 80N
OK
80 ~ 100N
OK
100 ~ 135N
OK
135 ~ 150N
OK
2) :
( : X, : O)
0 ~ 20N
OK
20 ~ 40N
OK
40 ~ 60N
OK
60~ 80N
OK
80 ~ 100N
OK
100 ~ 135N
OK
135 ~ 150N
OK
3.
No
20mm
070807-0100
/ (HeeTae Yang) / 2015-09-07 10:00/ , .