Directional Control Valve
Catalogue HY11-3500/UK
Series D1VW
Characteristics
The NG06 directional control valve series D1VW provides
high functional limits up to 80 l/min in combination with a
very low, energy-saving pressure drop.
A wide variety of spool options allows to design an unlimited number of hydraulic circuits.
Versions with 8 watt coils, position control, Atex approval,
surface protection and connector variants are shown in
the following chapters.
Technical data
General
Design
Actuation
Nominal size
Mounting interface
Mounting position
Ambient temperature
MTTFD value
Weight
Hydraulic
Max. operating pressure
Fluid
Fluid temperature
Viscosity permitted
Viscosity recommended
Filtration
Flow max.
Leakage at 50 bar
Static / Dynamic
Step response
Electrical characteristics
Directional spool valve
Solenoid
DIN NG06 / CETOP 03 / NFPA D03
DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03
unrestricted, preferably horizontal
[C] -25...+50
[years] 150
[kg] 1.5 (1 solenoid), 2.1 (2 solenoids)
[bar] P, A, B: 350; T: 210 (DC), T: 140 (AC)
Hydraulic oil in accordance with DIN 51524 / 51525
[C] -25 ... +70
[cSt] / [mm/s] 2.8...400
[cSt] / [mm/s] 30...80
ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
[l/min] 80 (see shift limits)
[ml/min] Up to 10 per flow path, depending on spool, up to 15 per flow path for spool type 008 + 009
see table response time
Duty ratio
Max. switching frequency
Protection class
100% ED; CAUTION: coil temperature up to 150 C possible
[1/h] 15000 (not for soft shift)
IP 65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code
K
J
U
G
Y
T
110V
at
50Hz/
230V
at
50Hz/
Supply voltage
[V]
12 V =
24 V =
98 V =
205 V =
120V at 60Hz 240V at 60Hz
Tolerance supply voltage
[%]
10
10
10
10
5
5
Current consumption hold
[A]
2.72
1.29
0.33
0.15
0.6 / 0.55
0.3 / 0.27
Current consumption in rush
[A]
2.72
1.29
0.33
0.15
2.5 / 2.4
1.25 / 1.2
Power consumption
hold
32.7 W
31 W
31.9 W
30.2 W
70 / 70 VA
70 / 70 VA
Power consumption
in rush
32.7 W
31 W
31.9 W
30.2 W
280 / 290 VA 280 / 290 VA
Solenoid connection
Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W).
Wiring min.
[mm] 3 x 1.5 recommended
Wiring length max.
[m] 50 recommended
With electrical connections the protective conductor (PE :) must be connected according to the relevant regulations.
D1VW UK.INDD RH 15.08.2011
2-7
Parker Hannifin Corporation
Hydraulics Group
Directional Control Valve
Catalogue HY11-3500/UK
Series D1VW
Ordering Code
Size 3-chamber Wet pin
Directional
armature
control DIN NG06 valve
CETOP 03
solenoid,
valve
NFPA D03
threaded
in tube
Spool
type
Spool
position
3 position spools
Code
001
002
Spool type
a
003
3 position spools
004
Code
Spool position
3 positions.
Spring offset in position 0.
Operated in position a or b.
005
006
Standard
007
008
009
Spool type 008,009,
204, 205
1)
1)
010
011
Operated in
position a.
Operated in
position b.
Spring offset in
Spring offset in
position b.
position a.
Operated in
position b.
Operated in
position a.
Spring offset in
Spring offset in
position a.
position b.
014
2 positions.
F
015
2 positions.
Spring offset in position 0.
Operated in position 0.
016
021
022
031
032
2 positions.
034
035
2 positions.
Spring offset in position 0.
Operated in position 0.
061
2 position spools
081
Code
082
102
204
1)
205
1)
020
a b
Spool type 083
2 position spools
Code
Spool position
Standard
Spool type
a
a b
2 positions.
Spring offset in position b.
Operated in position a.
2 positions.
Operated in position a or b.
No center or offset position.
2 positions.
Spring offset in position a.
Operated in position b.
026
030
083
1)
101
208
1)
Consider specific spool position.
D1VW UK.INDD RH 15.08.2011
2-8
Parker Hannifin Corporation
Hydraulics Group
Directional Control Valve
Catalogue HY11-3500/UK
Series D1VW
Ordering Code
W
Seals
Solenoid
voltage
Solenoid
Solenoid
connector as per option
EN 175301-803,
without plug
(other connectors
are available for
D1MW Series)
Design
series
(not required
for ordering)
Code
Solenoid option
Standard solenoid with
manual override
omit
T
without manual override
S2 3) Soft shift orifice size 0.5 mm.
S3 3) Soft shift orifice size 0.75 mm.
4N 3) with lockable manual override
3)
DC only
Code
Voltage
U 2)
G 2)
98V =
205V =
110V 50Hz /
120V 60Hz
230V 50Hz /
240V 60Hz
K
J
12V =
24V =
Y
T
2)
To be used in combination with
rectifier plugs at 120VAC / 230VAC
power supply.
Code
Seals
FPM
NBR
Further spool types, solenoid voltages and connectors on request.
D1VW UK.INDD RH 15.08.2011
2-9
Parker Hannifin Corporation
Hydraulics Group
Directional Control Valve
Catalogue HY11-3500/UK
Series D1VW
Flow Curve Diagram
Flow curve
14
24
10 9
13
8
7
20
6
5
16
11
12
Pressure drop [bar]
4
3
2
1
12
8
4
0
20
40
60
80
Flow [l/min]
All characteristic curves measured with HLP46 at 50C.
Spool
001
002
003
004
005
006
007
010
011
014
015
016
020B
026B
030B
034
035
081
082
101B
102
61
83H
104
208
008
009
83B
204
205
Spool
021
022
P-A
2
1
3
2
2
1
3
3
2
3
3
2
4
4
2
4
3
13
13
11
1
1
5
1
3
P-B
4
5
5
1
4
P-A
2
P-A
6
2
Position b
B-T
2
4
4
3
2
4
2
P-B
2
2
6
2
4
3
3
13
13
10
4
3
2
A-T
5
5
2
3
3
Position b
P-B
4
B-T
2
2
A-B
P-B
2
1
3
2
2
1
2
3
2
2
3
2
2
4
1
3
4
13
13
10
1
1
5
2
2
P-A
4
6
5
4
1
P-B
4
P-A
5
2
Position a
A-T
2
4
6
3
2
4
2
P-A
P-A
P-B
12
7
2
2
4
2
3
Position 0
A-T
B-T
P-T
5
7
7
7
3
2
14
2
14
5
7
7
5
13
13
9
4
3
2
5
1)
1)
5
3
5
2
B-T
5
7
2
3
3
P-A
7
12
2
3
14
P-B
A-T
14
B-T
P-T
9
7
Position a
A-T
2
P-B
2
A-B
1)
Only for pressure compensation,
no high flow possible.
D1VW UK.INDD RH 15.08.2011
2-10
Parker Hannifin Corporation
Hydraulics Group
7
5
Directional Control Valve
Catalogue HY11-3500/UK
Shift Limits
Series D1VW
The diagram below specifies the shift limits for valves with
DC solenoids. Valves with spool position F or M can
only be operated up to 70% of the limits. The specifications apply to a viscosity of 40mm2/s and balanced flow
conditions. The shift limits can be considerably lower at
unbalanced flow conditions. To avoid flow rates beyond
the shift limits, a plug-in orifice can be inserted in the
P-port.
Pressure [bar]
Pressure [bar]
Valve with standard DC solenoid
350
300
250
200
150
100
50
0
350
300
250
200
150
100
50
0
011
003, 004, 015
081
082
020, 030
021, 022
007, 008,
009, 014,
083
10
20
30
40
50
60
70
80
90
Flow [l/min]
001,002, 006
005, 016
010
026
10
20
30
40
50
60
70
Measured with HLP46 at 50C, 90% Unom and warm solenoids
90
80
Flow [l/min]
Pressure [bar]
Pressure [bar]
Valve with standard AC solenoid
350
300
250
200
150
100
50
0
350
300
250
200
150
100
50
0
005, 008,
016, 020
001
006, 030
004
002
007,
014, 081
026
20
30
10
101
082
10
20
005, 008,
016, 020
004
40
002
50
009,
011,
102
003, 015,
204, 205
30
60
70
80
90
Flow [l/min]
70
90
80
Flow [l/min]
010,021,
022
40
50
Measured with HLP46 at 50C, 95% Unom and warm solenoids
60
D1VW UK.INDD RH 15.08.2011
2-11
Parker Hannifin Corporation
Hydraulics Group
Directional Control Valve
Catalogue HY11-3500/UK
Series D1VW
Response Times
Supply pressure [bar]
Shift limit diagram - Soft shift with 1 DC solenoid
350
300
250
200
150
100
50
101
030
002,
020
10
20
009,
102
30
001, 004,
081
40
50
60
Supply pressure [bar]
Shift limit diagram - Soft shift with 2 DC solenoid
350
300
250
200
150
100
50
020D
10
002
20
081,
082
009
30
40
001,
004
50
60
Measured with HLP46 at 50C, 90% Unom and warm solenoids
Response times D1VW Standard and Soft Shift
Standard solenoid
Standard DC
Standard AC
Standard DC with rectifier plug
Response times
Soft Shift
Code
Orifice size
70
80
Flow [l/min]
70
80
Flow [l/min]
Orifice
Energize
De-energize
2 solenoid valve
3 positions
Center position: Closed
Energize
De-energize
2 solenoid valve
3 positions
Center position: Open
Energize
De-energize
1 solenoid valve
2 positions
w/o
w/o
w/o
45 - 60
13
60 -70
20 - 30
20
70- 90
Energize
S2
0.50mm
200 - 750
310 - 650
220 - 400
350 - 750
90 - 350
S3
0.75mm
180 - 300
300 - 400
200 - 350
300 - 500
90 - 350
The lower value applies to small flow rates and low pressure, the upper value to high flow rates and high pressure
De-energize
160 - 500
130 - 350
Step response times were obtained under the following conditions: HLP46 at 50C with the valve operating at nominal pressure and flow. Published
response times are nominal and may vary with spool, flow, pressure and temperature.
Acceleration for orifice size 0.75, code S3 (measured against a standard valve)
build-in orifice
For even softer shifting, the proportional spools 081, 082, 101 and 102 can be used.
D1VW UK.INDD RH 15.08.2011
2-12
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
Directional Control Valve
Interface EN 175301-803, DC solenoid
B, E, F -style
H, K, M -style
Series D1VW
Dimensions
91.4
69
22
22
69
93
9.5
93
9.5
A B
5.5
A B
5.5
46
162
C, D -style
134.6
162
46
Option 4N, with lockable manual override
(available for all styles, DC only)
9.5
93
22
69
93
9.5
22
A B
5.5
91.4
226
119.4
46
Interface EN 175301-803, AC solenoid
B, E, F -style
A B
5.5
190
H, K, M -style
9.5
84
69.5
93.5
22
22
69.5
93.5
9.5
B
5.5
46
152
A B
5.5
127
152
46
C, D -style
22
69.5
93.5
9.5
84
B
5.5
211
46
Surface finish
BK375
4x M5x30
DIN 912 12.9
7.6 Nm
15%
NBR: SK-D1VW-N-91
FPM: SK-D1VW-V-91
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm.
The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.
D1VW UK.INDD RH 15.08.2011
2-13
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
Notes
2-14
Parker Hannifin Corporation
Hydraulics Group
Directional Control Valve
Catalogue HY11-3500/UK
Characteristics
Series D1VW 8 Watt
The D1VW 8 Watt series is based on the standard D1VW
design. The low watt, low current (<0.5 A) solenoid allows
direct connection to a PLC or a bus knot. The valves
are offered with standard solenoid connection (as per
EN175301-803) and M12 x 1 connection. The version
with M12 x 1 connection and LEDs are conform to the
DESINA standard (DistributEd and Standardised INstAllation technology) for machine tools and manufacturing
systems.
Technical data
General
Design
Actuation
Size
Mounting interface
Mounting position
Ambient temperature
MTTFD value
Weight
Hydraulic
Max. operating pressure
Fluid
Fluid temperature
Viscosity permitted
Viscosity recommended
Filtration
Flow max.
Leakage at 50 bar
Static / Dynamic
Step response at 95%
Electrical characteristics
Directional spool valve
Solenoid
DIN NG06 / CETOP 03 / NFPA D03
DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03
unrestricted, preferably horizontal
[C] -25...+50
[years] 150
[kg] 1.5 (1 solenoid), 2.1 (2 solenoids)
[bar] P, A B: 350, T: 210
Hydraulic oil in accordance with DIN 51524 / 51525
[C] -25 ... +70
[cSt] / [mm/s] 2.8...400
[cSt] / [mm/s] 30...80
ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
[l/min] 60 (see shift limits)
[ml/min] Up to 10 per flow path, depending on spool
[ms] Energized: 80...120; De-energized: 35...55
Duty ratio
Max. switching frequency
Protection class
100% ED; CAUTION: coil temperature up to 70 C possible
[1/h] 10000
IP 65 in acc. with EN 60529, M12x1 IP67 (each with correctly mounted plug-in connector)
Code J
Supply voltage
[V] 24 V =
Tolerance supply voltage
[%] 10
Current consumption
[A] 0.33
Power consumption
[W] 8
Solenoid connection
Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code W).
Plug M12x1 on coil as per IEC 61076-2-101 (code D).
Wiring min.
[mm] 3 x 1.5 recommended
Wiring length max.
[m] 50 recommended
With electrical connections the protective conductor (PE :) must be connected according to the relevant regulations.
D1VW-8W UK.INDD RH 15.08.2011
2-15
Parker Hannifin Corporation
Hydraulics Group