Low voltage
Acti9
the efficiency you deserve
Catalogue
2010
Acti9
Summary
Acti9 offer presentation
General
Principle of catalogue numbers, protection (TIM)
CA901009
Circuit protection
Circuit breaker
Circuit breaker panorama
iC60a
iC60N
iC60H
iC60L
iC60LMA
C60H-DC
iK60 (B curve)
iK60 (C curve)
C120N
C120H
NG125a
NG125N
NG125H
NG125L
NG125LMA
iDPN, iDPN N
P25M
CA901000
CA901010
CA901002
CA901003
CA901004
CA901005
90102
CA901006
CA901007
CM901025
CM901024
CM901027
CM901028
CM901029
CM901030
CM901031
CM903012
CM901026
Switches
NG125NA
CM901035
Fuses
STI
SBI
IF
CM901033
CM901034
CM901032
Residual current device
Choice of earth leakage protection devices
Overview of the earth leakage protection product range
Vigi iC60
Vigi C120
Vigi NG125
iID
iID K
RCCB-ID 125 A
RCCB-ID type B
DPNa Vigi
DPN N Vigi
CA902000
CA902011
CA902005
CM902007
CM902008
CA902002
CA902007
CM902001
CM902002
91943
91942
Load protection (surge arrester)
PRF1 - PRD1
iPF
iPRD
version: 1.0
CM905001
CA903001
CA903002
CA909000E.indd
Acti9
Summary (cont.)
Accessories, auxiliaries
Accessorisation / Auxiliarisation iID, iC60, Vigi iC60
Accessories for iC60, iID
Electrical auxiliaries for iC60, iID, RCA and ARA
Accessories and auxiliaries for C120
and Vigi C120 devices
Accessories for C120 devices
Electrical auxiliaries for C120 devices
Accessories and auxiliaries for NG125 devices
Accessories for NG125 devices
Electrical auxiliaries for NG125 devices
CA907000
CA907001
CA907002
CM907001
CM907003
CM907002
CM907004
CM907006
CM907005
Control
iCT contactors
iTL impulse relays
iPB pushbuttons
iSSW linear switches
iSW switches
RCA remote controls for iC60 circuit breakers
ARA automatic reclosers for iC60 and iID
Reflex iC60 integrated control circuit breakers
CA904007
CA904008
CA904003
CA904004
CA904005
CA904011
CA904010
CA904012
Monitor
iIL indicator lights
Kilowatt-hour meters
CA904006
CA904009
Install
Infrastructure catalogue
Connection comb busbars for STI, DPN, iC60, iID,
C120, NG125
Distribloc 63 A
Distribloc 125 A
Multiclip 80 A
Printer
CA907006
CM907007
CA907003
CM907008
CA907004
CM907009
Technical advices
Tripping curves
CA908024
Short-circuit current limiting
CA908025
Cascading
557E4200
Auxiliaries contact indication
CA908028
Tripping auxiliaries
CA908029
Combination electrical auxiliaries for iC60, iID, RCA, ARA CA908030
Protection discrimination
557E4300/4305/4310/4320/4330
Direct current distribution
CA908006
Influence of ambient temperature
CA908007
Earth leakage protection
CA908023
Response time of high-sensitivity residual current devices CA908013
Response time of medium-sensitivity residual
current devices
CA908018
Routine operating checks
CA908012
Resistance to environmental conditions
CA908027
Temperature derating dissipated power and voltage
drop for C120
CM908001
Short-circuit current limitation for C120
iTL impulse relays and iCT contactors, choice of rating
according to load type
SBI / STI Fuse cartridges
CA909000E.indd
version: 1.0
CM908002
CA908026
CM908003
3
generations
of industry experience and 21 new patents
make Acti 9 the new reference in low voltage
modular systems
Acti 9
In short, I optimize my own energy.
The new core modular system that
makes your power distribution installation
safer, simpler and more efficient
High quality
modular
system without
compromise
We leveraged five generations of low voltage expertise
to design a precision, high quality modular system without
compromise. The Acti 9 offers the fastest and most
flexible installation experience, and completely eliminates
safety concerns during maintenance and operation.
Engineered to adapt to the most challenging networks
and environments while remaining cost-effective over time,
it is the most flexible, coordinated, comprehensive and
innovative range of low voltage modular systems available.
The Acti 9
gives you safety,
simplicity and
efficiency for the
lifespan of your
installation
Acti 9:
The 5th
generation
of modular
systems
F70
F32
Multi 9 -C32
Multi 9 -C60
Acti 9 - iC60
Acti 9
The safest, simplest and most efficient
system for power distribution solutions
Protection Systems
> Miniature circuit-breaker
> Residual current circuit breaker
> Vigi module
> Surge arrester
> Automatic Recloser Auxiliary
> Remote Control Auxiliary
> Electrical auxiliaries
Safer
More Efficient
VisiSafe and Class 2 give
complete safety for the life
of your installation
VisiTrip, Super immunization &
automatic reclosers increase
continuity of service,
enhance reliability
Control Systems
Installation Systems
> Contactors
> Impulse relays
> Indicator lights
> Pushbuttons
> Kilowatt hour meters
> Selector switches
> IP20B terminals
> Splitter block
> Full range of mounting
and wiring accessories
Simpler and Smarter
- Two certifications for one product, 100% MCB
& RCD coordination, easy ordering & design
- Fully BMS compatible, up to 50% less wiring, control
mode flexibility adapts to changes, 100% recyclable
3
Safe
Safest operation guaranteed even in
the most demanding environments
100%
safe for installers and
users in the most
severe environments
The best choice for
industrial and tertiary
buildings
Designed for safety, even in the most demanding environments
Safety matters most, and the Acti 9 system gives you, your customers, and their installations the
highest level of protection available. It guarantees 100% safe operation and maintenance for you
and your customers; its international certifications and numerous protection innovations mean
the Acti 9 system exceeds even the most demanding requirements to give you total safety during
maintenance, for the lifetime of your installation.
Comprehensive certification
Delivers complete industry-approved protection
The Acti 9 is fully tested, approved and certified by national and international third
parties. It guarantees that your installation is safe and compliant with all relevant
safety standards, and demonstrates to your customers that you use industryapproved materials and best practices.
I have no worries about the safety of the electrical
installation, the buildings and everyone inside.
Guarantees total safety
during maintenance
VisiSafe
VisiSafe guarantees the downstream
circuit is always safe, regardless of
overvoltage conditions, wear or
operator experience, even in the
most demanding environments.
VisiSafe
Only Available from
Schneider Electric
Promises absolute protection
against electric shocks
Only Available from
Schneider Electric
The green strip indicates the safe position
of contacts.
Unique safety features:
 Highest Impulse voltage withstand:
Uimp = 6 kV
 Guarantees heightened equipment
service life despite overvoltage
conditions.
Highest pollution resistance among
modular devices: Pollution degree:
level 3
 Promises a true all-terrain product
ideally suited for all environments,
even those with dust and
conductive pollution.
Leading edge insulation voltage:
500 V
 Complete safety for operators
maneuvering the operating handle
of the modular switchgear.
Protects the load and
guarantees long service life
Fast Closing Mechanism
Fast closure of all Acti 9 RCBs and
MCCBs limits wear and reduces voltage
drops, helping to prevent premature
equipment ageing and overheating.
Class 2 Front Face
The Acti 9 is the only device available with
this level of safety. Clearances between
breaker surfaces and internal parts are over
double the industry standard. It guarantees
risk-free handling during the life of the
installation, regardless of environment
or operator experience.
Provides zero-risk
lockdown to guarantee
protection and safety
Integrated Padlocking
Available for Acti 9 remote control devices,
the rugged, integrated padlock allows
complete lockdown for guaranteed protection
and safety. It prevents toggle device
movement and inadvertent or unauthorized
access, so you can ensure employee or
contractor safety at all times.
Efficient
The system that streamlines
your operations workflow
Designed to minimize downtime and avoid nuisance trips
With features like VisiTrip, which greatly reduces diagnostic and repair time, and super
immunization of the RCDs to guarantee the highest continuity of service available, the Acti 9
system allows easier building management, eliminates downtime and makes your business
even more competitive, limiting intervention costs on distant infrastructure sites.
Less downtime, more continuity of service
VisiTrip minimizes downtime and reduces repair times
Identify faults in one glance, and easily see the operating status of your network.
VisiTrip indicates only the faulty outgoer, allowing fast diagnosis, resolution and
re-closing loads for easier building management and reduced downtime.
Only Available from
Schneider Electric
VisiTrip
When I install the Acti 9 I know I dont
have to come back to the job.
100%
preventative
maintenance
0
downtime
Prevents unnecessary trips
Only Available from
Schneider Electric
Super immunization (SI) of the RCDs
guarantees the highest continuity of
service and electrical immunity, especially
where switchgear contends with
electromagnetic or chemical interference.
It also meets the high continuity of
service requirements in all critical power
applications (hospitals, data centres,
telecom and tunnels).
No need for onsite intervention
Enhances service
reliability
Acti 9 devices provide maximum continuity
of service. Extended discrimination ranges
allow for a variety of solutions for continuity
of service, restricting downtime to only the
affected circuit and leaving the rest of your
installation intact.
The Acti 9 introduces a new automatic
recloser auxiliary (ARA iC60) designed to
limit the cost of intervention on far away
infrastructure sites. No need to have
permanent on-site teams responding
to transient faults, limiting distant site
intervention costs.
Simple and Smart
The right solution for every application
The Acti 9 simplifies final distribution operations in buildings and industrial facilities, giving
you the right solution with the right technical characteristics, for every application. As new
installation standards emerge or building requirements are modified, the Acti 9 system
can easily scale to meet your needs. Its a flexible, open system with all-in-one, integrated
components that can communicate with any Building Management System.
Designed to be simple to choose, easy
to design, and straightforward to install
Easy to design and choose
Meets two certifications
The Acti 9 complies with both
IEC/EN 947 (industrial) and IEC/EN 898
(tertiary) standards  two certifications
in one product  making it perfect for
commercial and industrial applications.
Supports intuitive ordering and design
Meaningful part numbers mean no
mistakes and no doubts when ordering
or designing. Get the product type, poles
and rating in one glance.
A9XXX225 = 2P, 25A
Conforms to any BMS
Reflex iC60 has integrated signal auxiliaries for complete simplicity. Its control
mode flexibility easily adapts to changes
in your installation, optimizing design time
for lighting and building control.
Guarantees 100%
coordination
100% coordination between RCDs
and MCBs means no more searching
through technical guides or coordination
tables. Plus, in the Reflex iC60 the MCB
and internal actuator are a unique all
in one concept fully covered by the
manufacturer warranty.
30%
of switchboards
are modified at
design, cabling or
commissioning
stages, increasing
project start-up times
Reflex iC60: The all in one concept integrated
control circuit-breaker of the Acti 9 system
The Reflex iC60 combines an MCB with an internal actuator. Designed to
evolve and adapt with the dynamic requirements of tertiary and industrial lighting
control applications, it easily communicates with PLCs and BMS systems without
the need for add-ons, retrofits or extras. Everything you need is included.
Only Available from
Schneider Electric
Simple and Smart
100%
coordination
between MCB
and actuator
15%
time saved on
design and
installation
Easy to install
Up to 50% less wiring
Reflex iC60 all-in-one concept means
up to 50% less wiring for reduced
cabling and more efficient verification
and connection.
Lighting control solution without (left) & with (right) Reflex iC60 all in one concept
Allows heavy-duty, reliable tightening
Safe and secure connections
Twice the terminal tightening torque for more robust connections.
Provides secure connections with quick,
ergonomic and safe IP20B terminals shutters.
10
Everything is simpler with Acti 9. Whatever
the application, I have no second thoughts.
Easy to operate
Allows quick intervention
Provides greater readability
Large circuit ID area for no doubt about
referenced circuits. Acti 9 label maker
gives a professional appearance.
Ergonomic interface with specific color coding for locking
padlocking devices. N indication for easy readability and
speed of servicing.
Easy to upgrade
Comes with tailored accessories
Adapts to your installation
The Acti 9 system includes a comprehensive list of accessories:
easily-installed padlock system, splitter block, rotary handle mount
for switchboard doors, screw shields, sealable terminal shields,
plug-in base, interpole barrier, clip-on markers.
Double DIN rail locker allows circuit changeouts
without removing the comb. It adapts to new
requirements and simplifies switchboard evolution.
Evolves with changing
site requirements
Multiclip distribution system allows you to
quickly add outgoers and balance phases.
Multiclip offers screwless, safe connections.
11
Attractive and
environmentally friendly
Advanced ergonomics and attention to all detail
Acti 9 lets you
touch and feel
the difference
The Acti 9 is designed to be noticed. We incorporated clean lines with distinctive,
gently rounded shapes to give the Acti 9 its faultless appearance. It immediately
suggests well-designed and user-friendly aesthetics and particular attention
to detail. Clarity of identified circuits and elegant appearance will have your
customers impressed with their outstanding installations.
High quality, subtle and precise
Even holding the Acti 9 in your hand, the Acti 9 feels high quality. Contacts
close quickly and precisely, with no hint of dubious noise. The solid fit of its
components and its smooth surfaces mean you can feel the difference even
before you use it.
12
You can tell its a high quality product
when you hold it in your hands.
A better use of energy, from start to finish
100%
The Acti 9 helps you meet developing energy efficiency and environmental
certifications or requirements, now and in the future. It minimizes impact
from the design stage, through the installations lifetime of use, and
eventual recycling. Through both design and technology, the Acti 9
provides you with the key combination of less impact and more efficiency
that is necessary for the environment today.
100% recyclable
and recoverable
materials
The Acti 9: your safe, efficient and simple
choice for low voltage modular systems.
100% RoHS
compliant
100% REACH
20%
savings in
energy losses
13
Protection
Circuit protection
Earth leakage protection
Principle of catalogue numbers
iID, iC60, Vigi iC60, Reflex iC60
Description
A9 R 15 2 63
Range
Family
Code
Code
Rating (A) Code
Acti9 (A9)
iID
00
Vigi iC60
iC60
V
F
1P
2P
0.5
0.75
70
71
Internal code Poles
iK60
3P
01
Auxiliaries and accessories
4P
1.6
72
Switches
1N
02
Reflex iC60
1P+N
2.5
73
3P+N
03
04
06
6.3
76
08
10
10
12.5
82
13
13
16
16
20
20
25
25
32
32
40
40
50
50
63
63
80
80
100
91
125
92
version: 1.1
CA901009E.indd
Protection
Circuit protection
Circuit breaker panorama
Selection guide
Circuit breakers
Type
Standard
Quality label
Number of poles
Add-on residual current devices (Vigi)
Auxiliaries for remote tripping and indication
Electrical characteristics
Curves
Ratings (A)
In
Maximum operational voltage (V)
Ue
max
Minimum operational voltage (V)
Ue
min
Insulation voltage (V AC)
Ui
Rated impulse withstand voltage (kV)
Uimp
Breaking capacity
AC-Breaking capacity
IEC 60947-2 (kA)
Icu
AC (50/60 Hz)
DC
AC (50/60 Hz)
DC
Icn
Icu
iDPN N
IEC/EN 60898-1
Country approval pictogram
1P+N
b
b
IEC/EN 60898-1
Country approval pictogram
1P+N, 3P, 3P+N
b
b
B, C
1 to 40
230
440
4
C, D
1 to 40
230/400
440
4
Ue
(50/60 Hz)
12...60 V
12...133 V
100...133 V
220...240 V
380...415 V
440 V
4500
6000
b
b
Upstream connection
IP20
IP40
b
b
Upstream connection
IP20
IP40
CM903012
CM903012
CM907002
CM903012
CM903012
CM907002
Ics
EN 60898 (A)
DC-Breaking capacity
IEC 60947-2 (kA)
iDPN
230/400 V
Ue
DC
12...60 V (1P)
100...133 V (2P)
100...133 V (3P)
220...250 V (4P)
Ics
Other characteristics
Suitable for industrial isolation according to IEC/EN 60947-2
Fault tripping indication
Positive contact indication
Fast closing
Dismounting with comb busbar in place
Degree of protection
IP
Device only
Device in modular
enclosure
For more detail, see module
Accessories
Auxiliaries
Add-on residual current devices (Vigi)
(1) 100 % of Icu for ratings 6 to 25 A under Ue 100 to 133 V AC Ph/Ph and Ue 12 to 60 V AC Ph/N.
version: 1.0
CA901000E.indd
Protection
Circuit protection
Circuit breaker panorama (cont.)
iK60N
iC60a
iC60N
iC60H
iC60L
IEC/EN 60898-1
Country approval pictogram
1P, 1P+N
2, 3, 4P
IEC/EN 60898-1
Country approval pictogram
1P
2, 3, 4P
b
b
IEC/EN 60947-2, 60898-1
Country approval pictogram
1P, 1P+N
2, 3, 4P
b
b
IEC/EN 60947-2, 60898-1
Country approval pictogram
1P, 1P+N
2, 3, 4P
b
b
IEC/EN 60947-2, 60898-1
Country approval pictogram
1P
2, 3, 4P
b
b
B, C
1 to 63
440
12
400
4
C
1 to 63
415
220
500
6
B, C, D
0.5 to 63
440
250
12
12
500
6
B, C, D
0.5 to 63
440
250
12
12
500
6
B, C, K, Z
0.5 to 63
440
250
12
12
500
6
Ph / N
Ph / Ph
Ph / N
Ph / Ph
50 (0.5 to 4 A)
20 (6 to 63 A)
10
50 (0.5 to 4 A)
10 (6 to 63 A)
50 (0.5 to 4 A)
20 (6 to 63 A)
70 (0.5 to 4 A)
15 (6 to 63 A)
70 (0.5 to 4 A)
30 (6 to 63 A)
50 (0.5 to 4 A)
10 (6 to 63 A)
70 (0.5 to 4 A)
15 (6 to 63 A)
25 (0.5 to 4 A)
6 (6 to 63 A)
50 (0.5 to 4 A)
10 (6 to 63 A)
100 % of Icu (0.5 to 4 A)
75 % of Icu (6 to 63 A)
6000
6000
15
100 % of Icu
100 % of Icn
100 % of Icu
6000
6000
4500
4500
100 % of Icu
Upstream connection
IP20
IP40
Insulation class II
CA901006 and CA901007
CA901000E.indd
b
Visi-trip window
b
b
Upstream connection
IP20
IP40
Insulation class II
CA901010
CA907000 and CA907001
CA907000 and CA907002
CA902005
Ph / N
50 (0.5 to 4 A)
36 (6 to 63 A)
Ph / Ph
50 (0.5 to 4 A)
36 (6 to 63 A)
20
30
40
b
Visi-trip window
b
b
Upstream connection
IP20
IP40
Insulation class II
CA901002
CA907000 and CA907001
CA907000 and CA907002
CA902005
version: 1.0
Ph / N
70 (0.5 to 4 A)
42 (6 to 63 A)
Ph / N
100 (0.5 to 4 A)
70 (6 to 63 A)
Ph / Ph
100 (0.5 to 4 A)
80 (6 to 63 A)
100 (0.5 to 4 A)
50 (6 to 25 A)
36 (32/40 A)
30 (50/63 A)
100 (0.5 to 4 A)
25 (6 to 25 A)
20 (32/40 A)
15 (50/63 A)
100 (0.5 to 4 A)
70 (6 to 63 A)
100 % of Icu (0.5 to 4 A)
75 % of Icu (6 to 63 A)
10000
10000
100 (0.5 to 4 A)
50 (6 to 25 A)
36 (32/40 A)
30 (50/63 A)
100 (0.5 to 4 A)
25 (6 to 25 A)
20 (32/40 A)
15 (50/63 A)
70 (0.5 to 4 A)
20 (6 to 25 A)
15 (32/40 A)
10 (50/63 A)
100 % of Icu (0.5 to 4 A)
50 % of Icu (6 to 63 A) (1)
15000
15000
20
100 % of Icu
25
100 % of Icu
30
50
70
70 (0.5 to 4 A)
30 (6 to 63 A)
Ph / Ph
70 (0.5 to 4 A)
42 (6 to 63 A)
25
40
50
b
Visi-trip window
b
b
Upstream connection
IP20
IP40
Insulation class II
CA901003
CA907000 and CA907001
CA907000 and CA907002
CA902005
b
Visi-trip window
b
b
Upstream connection
IP20
IP40
Insulation class II
CA901004
CA907000 and CA907001
CA907000 and CA907002
CA902005
Protection
Circuit protection
Circuit breaker panorama (cont.)
Selection guide (cont.)
Circuit breakers
Type
C120N
C120H
Standard
IEC 60947-2, IEC/EN 60898-1
IEC 60947-2, IEC/EN 60898-1
Quality label
Country approval pictogram
Country approval pictogram
Number of poles
1P
Add-on residual current devices (Vigi)
2, 3, 4P
1P
Auxiliaries for remote tripping and indication
2, 3, 4P
Electrical characteristics
Curves
Ratings (A)
Maximum operational voltage (V)
In
Ue
max
B, C, D
B, C, D
63, 80, 100, 125
10 to 125
AC (50/60 Hz)
240/440
240/440
DC
125 per pole
125 per pole
AC (50/60 Hz)
12
12
Minimum operational voltage (V)
Ue
min
12
12
Insulation voltage (V AC)
Ui
500
500
Rated impulse withstand voltage (kV)
Uimp
DC
Breaking capacity
AC-Breaking capacity
IEC 60947-2 (kA)
Ue
Icu
(50/60 Hz) Ph / N
110...130 V
Icn
DC-Breaking capacity
IEC 60947-2 (kA)
Ph / N
Ph / Ph
130 V
20
30
230/400 V
10
20
15
30
380...415 V
400/415 V
3 (1)
10
4.5 (1)
15
440 V
10
500 V
230/400 V
10000
10000
15000
75 % of Icu
Ue
Icu
Ph / Ph
220...240 V
Ics
EN 60898 (A)
50 % of Icu
60 V (1P)
10
15
125 V (1P)
10
15
250 V (2P)
10
15
500 V (4P)
100 % of Icu
100 % of Icu
Other characteristics
Suitable for industrial isolation according to IEC/EN 60947-2
Ics
Fault tripping indication
Positive contact indication
Fast closing
Dismounting with comb busbar in place
Special comb busbar
Special comb busbar
Degree of protection
For more detail, see module
IP
15000
DC
Device only
IP20
IP20
Device in modular IP40
enclosure
IP40
Accessories
CM901025
CM907001 and CM907003
CM901024
CM907001 and CM907003
Auxiliaries
CM907001 and CM907002
CM907001 and CM907002
Earth leakage module (Vigi)
CM902007
CM902007
(1) Breaking capacity under 1 pole with IT isolated neutral system (case of double fault).
version: 1.0
CA901000E.indd
Protection
Circuit protection
NG125a
Circuit breaker panorama (cont.)
NG125N
NG125H
NG125L
IEC/EN 60947-2
IEC/EN 60947-2
IEC/EN 60947-2
IEC/EN 60947-2
Country approval pictogram
Country approval pictogram
Country approval pictogram
3, 4P
1P
1P
B, C, D
B, C, D
80 to 125
10 to 125
10 to 80
10 to 80
500
240/500
240/500
240/500
125 per pole
125 per pole
125 per pole
2, 3, 4P
2, 3, 4P
Country approval pictogram
1P
12
12
12
12
12
12
12
690
690
690
690
2, 3, 4P
Ph / Ph
Ph / N
Ph / Ph
Ph / N
Ph / Ph
Ph / N
Ph / Ph
50
70
100
25
50
36
70
50
100
16
25
36
50
20
30
40
10
12
15
75 % of Icu
75 % of Icu
25
36
50
25
36
50
25
36
50
25
36
50
100 % of Icu
75 % of Icu
75 % of Icu
100 % of Icu
100 % of Icu
Toggle position
Toggle position
Toggle position
Toggle position
IP20
IP20
IP20
IP20
IP40
IP40
IP40
IP40
CM901027
CM901028
CM907004 and CM907006
CM901029
CM907004 and CM907006
CM901030
CM907004 and CM907006
CM907004 and CM907005
CM907004 and CM907005
CM907004 and CM907005
CM907004 and CM907005
CM902008
CM902008
CM902008
CM902008
CA901000E.indd
version: 1.0
CM907004 and CM907006
Protection
Motor protection
Circuit breaker panorama (cont.)
Selection guide (cont.)
Instantaneous circuit breakers (ICB)
Type
Standard
Quality label
Number of poles
Add-on residual current devices (Vigi)
Auxiliaries for remote tripping and indication
Electrical characteristics
Curves
Ratings (A)
In
Maximum operational voltage (V)
Ue
max
Minimum operational voltage (V)
Ue
min
Insulation voltage (V AC)
Ui
Rated impulse withstand voltage (kV) Uimp
Breaking capacity
AC-Breaking capacity
IEC 60947-2 (kA)
Icu
AC (50/60 Hz)
DC
AC (50/60 Hz)
DC
Ue
(50/60 Hz)
12...60 V
12...133 V
100...133 V
110...130 V
130 V
220...240 V
230/400 V
380...415 V
400/415 V
440 V
500 V
EN 60898 (A)
DC-Breaking capacity
IEC 60947-2 (kA)
Ics
Icn
Icu
230/400 V
Ue
DC
12...60 V (1P)
60 V (1P)
100...133 V (2P)
125 V (2P)
100...133 V (3P)
220...250 V (4P)
500 V (4P)
Ics
Other characteristics
Suitable for industrial isolation according to IEC/EN 60947-2
Fault tripping indication
Positive contact indication
Fast closing
Dismounting with comb busbar in place
Degree of protection
IP
Device only
Device in modular
enclosure
For more detail, see module
Accessories
Auxiliaries
Add-on residual current devices (Vigi)
iC60LMA
NG125LMA
IEC/EN 60947-2
Country approval pictogram
2, 3, 4P
b
b
IEC/EN 60947-2
Country approval pictogram
2, 3P
b
b
MA
1.6 to 40
440
250
12
12
500
6
MA
4 to 80
500
12
690
8
100 (1.6 to 4 A)
50 (6.3 to 25 A)
36 (40 A)
100 (1.6 to 4 A)
25 (6.3 to 25 A)
20 (40 A)
50 (1.6 to 4 A)
20 (6.3 to 25 A)
15 (40 A)
50 % of Icu (1.6 to 40 A)
100
b
Visi-trip window
b
b
Upstream connection
IP20
IP40
Insulation class II
CA901005
CA907000 and CA907001
CA907000 and CA907002
CA902005
b
Toggle position
b
b
IP20
IP40
version: 1.0
50
40
15
75 % of Icu
CM901031
CM907004 and CM907006
CM907004 and CM907005
CM902008
CA901000E.indd
Protection
Motor protection
Circuit breaker panorama (cont.)
Selection guide (cont.)
P25M circuit breakers
Type
P25M
Standard
Quality label
Number of poles
Add-on residual current devices (Vigi)
Auxiliaries for remote tripping and indication
IEC 60947-2 and IEC 60947-4-1
CEBEC, DEMCO, NEMKO, SEMKO, FI
3P
Electrical characteristics
Magnetic tripping
Ratings (A)
Maximum operational voltage (V)
Minimum operational voltage (V)
Insulation voltage (V AC)
In
Ue
max
Ue
min
AC (50/60 Hz)
12 In ( 20 %)
0.16 to 25 (63 A with limiter block)
690
DC
AC (50/60 Hz)
230
DC
Ui
690
Rated impulse withstand voltage (kV) Uimp
Breaking capacity
AC-Breaking capacity
IEC 60947-2 (kA)
Ue
Icu
(50/60 Hz)
230...240 V
Ics
Icu
400...415 V
Ics
Icu
440 V
Ics
Icu
500 V
Ics
Icu
690 V
Ics
Ratings (A) 0.16 to 1.6 2.5
23
25
Unlimited
6.3
10
14
18
50
50
100 % of Icu
Unlimited
15
50 % of Icu
40 % of Icu
Unlimited
50
100 % of Icu
50 % of Icu
Unlimited
50
100 % of Icu
75 % of Icu
Unlimited
75 % of Icu
15
15
10
3
8
6
3
15
15
Other characteristics
Suitable for industrial isolation according to IEC/EN 60947-2
Fault tripping indication
Positive contact indication
Fast closing
Dismounting with comb busbar in place
Degree of protection
IP
Device only
Device in modular
enclosure
For more detail, see module
b
Toggle position
IP20
IP40
CM901026
Accessories
CM901026
Auxiliaries
CM901026
Add-on residual current devices (Vigi)
CA901000E.indd
version: 1.0