Trans Basic Operation:
Shift delay and pressure rise are controlled by vacuum modulator, while the up-shift signal is produced from output shaft mounted governor.
A kick-down rod is also used but only for full throttle
kick-downs.
Oldies but Goodies Trivia...
1964-66 years were Green Dot Drive applications.
Selector positions were P,R,N,D2,D1 & Low. D2
function was 2nd gear start and auto shift to 3rd.
D1 function was 1st gear start and auto shift to 2nd
and 3rd. Manual Low provides 1st gear only.
C4/C5 - General Reference Data
Intermediate Tighten 10 ft pounds
and back off 1 3/4 turns
Line Tap
Line Pressure Specs
Drive - Idle 55-65 WOT 150-165
Reverse - Idle 60-110 WOT 240-270
L/R hub freewheels CW.
Clutch & Band Application Chart
Forward
Clutch
High
Clutch
Intermediate
Band
Low/Reverse
Band
Low
Sprag
Locked
Park
Applied
Reverse
Applied
Locked
Neutral
Drive (D)
1st Speed
Applied
Drive (D)
2nd Speed
Applied
Drive (D)
3rdSpeed
Applied
Manual 2
2nd Speed
Applied
Manual Low (1)
Applied
Locked
Applied
OR*
Applied
OR*
Applied
OR*
Applied
Locked
OR* = Overunning
Cooler return rear line
Servo ID and Ratio
Stronger/Firmer Shift < - - > Weaker/Softer Shift
Reverse Tighten 10 ft. pounds
and back off 3 turns
Direct Forward
Servo
Release
Modulators can be push-in style or screw-in style.
Letter
Code
Apply
Dia.
3.130
2.960
2.825
2.825
2.710
2.500
2.560
2.460
Release
Dia.
3.785
3.785
3.265
3.785
3.785
3.335
3.785
3.785
Ratio
%
68%
61%
75%
56%
51%
56%
46%
42%
Servo
Apply
Modulator Pin Length
Modulator
Type
Minimum
Length
Average
Length
Maximum
Length
Push
In
1 19/32
1 5/8
1 11/16
Screw
In
1 5/8
1 11/16
1 3/4
Governor springs and valves
vary by model and axle ratio.
Gov
Output
Low
Reverse
Gov
Feed
Air Checks
 TransGo 2006