AX96                     U241E AUTOMATIC TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM
Shift Solenoid "D" Control Circuit Low (Shift
           DTC                   P0982
                                                   Solenoid Valve S4)
                                                   Shift Solenoid "D" Control Circuit High (Shift
           DTC                   P0983
                                                   Solenoid Valve S4)
AX   DESCRIPTION
     Shifting from 1st to O/D is performed in combination with the ON and OFF operation of the shift solenoid
     valves SL1 and SL2, which are controlled by the ECM. If an open or short circuit occurs in any of the shift
     solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be
     operated safely (see page AX-31).
     DTC No.                                        DTC Detection Condition                           Trouble Area
     P0982                                          ECM detects short in solenoid valve S4 circuit       Short in shift solenoid valve S4 circuit
                                                    2 times when solenoid valve S4 is operated (1        Shift solenoid valve S4
                                                    trip detection logic)                                ECM
     P0983                                          ECM detects open in solenoid valve S4 circuit        Open in shift solenoid valve S4 circuit
                                                    2 times when solenoid valve S4 is not                Shift solenoid valve S4
                                                    operated (1 trip detection logic)                    ECM
     MONITOR DESCRIPTION
     This DTC indicates an open or short in the shift solenoid valve S4 circuit. The ECM commands gear shifts
     by turning the shift solenoid valves ON/OFF. When there is an open or short circuit in any shift solenoid
     valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. Also, the ECM
     performs the fail-safe function and turns the other normal shift solenoid valves ON/OFF. In case of an
     open or short circuit, the ECM stops sending current to the circuit (see page AX-31).
     MONITOR STRATEGY
                                                                            P0982: Shift solenoid valve S4/Range check (Low resistance)
     Related DTCs
                                                                            P0983: Shift solenoid valve S4/Range check (High resistance)
     Required sensors/Components                                            Shift solenoid valve S4
     Frequency of operation                                                 Continuous
     Duration                                                               0.128 sec.
     MIL operation                                                          Immediate
     Sequence of operation                                                  None
     TYPICAL ENABLING CONDITIONS
     P0982: Range check (Low resistance)
     The monitor will run whenever this DTC is not present.                 None
     Shift solenoid valve S4                                                ON
     Battery voltage                                                        8 V or more
     Ignition switch                                                        ON
     Starter                                                                OFF
     P0983: Range check (High resistance)
     The monitor will run whenever this DTC is not present                  None
     Shift solenoid valve S4                                                OFF
     Battery voltage                                                        8 V or more
     Ignition switch                                                        ON
     Starter                                                                OFF
                          U241E AUTOMATIC TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM                                        AX97
TYPICAL MALFUNCTION THRESHOLDS
P0982: Range check (Low resistance)
Shift solenoid valve S4 resistance                               8  or less
P0983: Range check (High resistance)
Shift solenoid valve S4 resistance                               100 k or more
                                                                                                                                      AX
COMPONENT OPERATING RANGE
Shift solenoid valve S4                                          Resistance: 11 to 15  at 20C (68F)
WIRING DIAGRAM
                                                                                                           ECM
                Shift Solenoid Valve S4
                (ECT Solenoid Valve)
                                                                                                         S4
                                          S4
                                                                                                                         C119178E12
INSPECTION PROCEDURE
   1       INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S4)
                                                       (a) Disconnect the B27 wire connector.
                                                       (b) Measure the resistance of the transmission wire.
                                                           Standard resistance
                                                       Tester Connection          Condition              Specified Condition
                                                       8 (S4) - Body ground       20C (68F)            11 to 15 
                                                        NG                        Go to step 3
                            S4
                                          C129039E04
   OK
     AX98           U241E AUTOMATIC TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM
       2     CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM)
                                                       (a) Disconnect the B30 ECM connector.
                                                       (b) Measure the resistance of the wire harness side
                                                           connector.
                                                           Standard resistance
     Wire Harness Side
AX                            B30                      Tester Connection    Condition            Specified Condition
                                                       B30-78 (S4) - Body   20C (68F)          11 to 15 
                                                       ground
                                                        NG           REPAIR OR REPLACE HARNESS AND
                                                                     CONNECTOR
                         S4
                                          A107892E22
       OK
     REPLACE ECM
       3     INSPECT SHIFT SOLENOID VALVE S4
                                                       (a) Remove the shift solenoid valve S4.
                                                       (b) Measure the resistance of the solenoid valve.
                          (+)       (-)
                                                           Standard resistance:
                                                             11 to 15  at 20C (68F)
                                                       (c) Connect the battery's positive (+) lead to the terminal of
                                                           the solenoid valve connector, and the negative (-) lead to
                                                           the solenoid body. Then check that the valve moves and
                                                           makes an operating noise.
                                                           OK:
                                      G028386E02             Valve moves and makes operating noise.
                                                        NG           REPLACE SHIFT SOLENOID VALVE S4
       OK