Rex Catalog
Rex Catalog
Together we offer:
   Innovative solutions
   Energy Savings
   Easy programming
   Easy installation
   Reliable support and service
2
               Table of Contents
                                                                                                                                                         3
    Rex - digital time switches
    AlphaRex
NEW
A40 107
Reference Reference
Dimensions
         According to UL 60730-1, UL 60730-2-7, VDE 631-1 and 631-2-7, IEC 60 730-1 and                             1.42                              1.97
         60 730-2-7, EN 60 730-1 and 60 730-2-7                                                                     36 mm                             50 mm
          with text based programming concept
          selectable languages: English, German, French, Italian, Spanish and Dutch
          fast programming due to selection of pre-set groups of days Mo-Su, Mo-Fr, Sa-Su
           and individual selection of days
          easy programming with PC using Rex software and data key
                                                                                                    83 mm
                                                                                                                                                                              45 mm
                                                                                                     3.27
1.77
          a program consists of an ON and OFF time and their assignment to certain days
          backup on data key possible
          with additional functions:
           - holiday program
           - random function
           - pulse function (only 1 channel) with pulse duration of 1 sec up to 59 min., 59 sec.
             and 84 start times (NOT D22 and D21s)
           - hour counter for max. 65,535 hours.                                                                                                          2.6
          background lighting for display and buttons                                                                                                   66 mm
          running reserve of 6 years for date and time
          programs are stored in a EEPROM
          programs are shown as a weekly matrix on the display
          automatic summer-/wintertime change (daylight saving)
          precision +/ 0.2 sec/day
          manual switching
          lead sealable cover, even with inserted data key
4
                                Rex - digital time switches
                                AlphaRex
               Programming
                A program consists of an ON and OFF time and the assigned day(s). Before setting the ON and OFF times, the requested days have to be selected:
                MONDAY-SUNDAY, MONDAY-FRIDAY, SATURDAY-SUNDAY or INDIVIDUAL.
                The INDIVIDUAL mode allows to select every single day of the week. It is also possible to program over midnight.
               Relay function
                With MENU and FUNCTION it is possible to change the relay position. By default it is AUTO, the time switch switches at the programmed times.
                Additional selections are: CONST ON, CONST OFF and EXTRA. With choosing EXTRA the stored program will be inverted.
                When the next programmed switching time has been reached, the time switch returns to normal mode.
               Holiday
                Selection the HOLIDAY function allows to set the start- and end date of the holidays and has to be activated by selecting ACTIVE, or deactivate it
                by selecting PASSIVE. When the HOLIDAY function is activated, the stored program will be ignored during the selected days and replaced
                by CONST ON or CONST OFF. When holiday is over, the AlphaRex return to default mode.
               Data key
                When the time switch is connected to the power supply, the data key activates automatically the DATA KEY menu with the options READ and WRITE.
                WRITE: programs stored in the time switch will be copied into the data key. Eventually stored programs on the data key will be overwritten!
                READ: programs stored on the data key will be copied into the time switch. Eventually stored programs on the time switch will be overwritten.
                It is only possible to save 1 time switch program which consist of max. 56 ON/OFF (1 channel) or max. 84 ON (1 channel pulse) or
                max. 2 x 28 ON/OFF (2 channel) on the time switch and the data key.
                When inserting the data key without the time switch being connected to the supply, the DATA KEY menu will not appear automatically, but has to be selected manually!
               Programming on the PC
                Next to the easy and text based programming directly on the time switch, it is also possible to do it on your PC by using the Rex software and to transfer
                the program with the data key to the time switch. To save the PC-created programs on the data key, the USB-adapter has to be installed.
                System requirements: USB-port; Windows98 second edition; Windows2000; WindowsME or WindowsXP, 10MB free disc space
               Reset
                Pressing simultaneously on all 4 buttons for more than 2 seconds, will cause a deletion of all stored data. Language, time/date, summer / winter time and
                switching programs will need to be reinstalled.
                                                                                                                                                                                             5
LIGHT CONTROL
                                                              >>>               Rex - Astronomical
                                                                                time switches
                                                                                AlphaRex Astro
Rex
astronomical
time switches
Easy control of light based on the calculation
of sunrise and sunset, with no need of                                                                             A45 195
installing a light sensor!
Reference
Technical data
 1)
      Each program comprises a switch-on and switch-off
      time and the associated on and off days or day blocks.
                                                                                                                   45 mm
                                                                                        3.27
1.77
                                                                                                            2.6
                                                                                                           66 mm
Functions
MENU              Menu selection, one step back, press and hold for more than 1 second
                  to return to main display
                                                                                                                            7
    Rex-light controllers
    AlphaRex-Astro time switch
    Basic settings
      Menu guidance
       The AstroRex guides the user through the programming and setup in plain English. Every step can be read off on the display; the momentarily active function is
       indicated by a flashing light. Integrated display and push-button illumination makes operation easier even in poor visibility.
       The language can be selected via the "MENU" button. English is set on delivery.
       The time switch is set to the actual time and date by the manufacturer, as well as to the summer / winter time applicable in Europe. Times can be changed via "MENU" +
       "SET".
Position (astro)
       The different daily sunrise and sunset times are calculated for the position programmed in the AstroRex. "GERMANY - SOEST" is set on delivery. The actual position
       should be entered for optimum operation. This can be done in two ways: via "MENU", "SET" and "ASTRO" to the two options "POSITION" and "COORDINATES".
"POSITION": The town and country closest to the position of use can be selected via this menu item.
       "COORDINATES": The coordinates of the actual location can be entered in this menu item if desired. Information on
       coordinates and time zones can be found in the time zone map enclosed with every time switch or can be found on the internet.
Offset
       Time differences in relation to the calculated switching times can be set via "MENU", "SET", "ASTRO" and "OFFSET". The actual switching time can be offset by up to
       +/- 120 minutes in relation to the sunrise and sunset times by entering a time difference. This time is set separately for sunrise and sunset.
                                                                                                              Example:
                                                                                                              If an offset of +30 minutes is entered, the time
       t                                                                                                      switch switches 30 minutes after sunrise and
           0h         3          6           9         12         15          18         21         24h       30 minutes after sunset.
8
                            Rex-light controllers
                            AlphaRex-Astro time switch
   The relay setting can be changed via "MENU" and "FUNCTIONS". The default function is "AUTO", i.e. the time switch switches at the programmed times. Other options available are:
   "CONST ON", "CONST OFF" and "EXTRA". If "EXTRA" is selected, the switch status specified by the program is reversed. Switch-on and switch-off are controlled by the programmed
   switching times with the next switching command.
Holiday time
   The start and end time of the holiday period are set in the holiday program and activated with the program item "ACTIVE" or deactivated with the program item "PASSIVE". If the holiday
   program is active, the time switch will not execute any programmed switch commands during the corresponding period, but remains "CONST ON" or "CONST OFF" as preferred during
   the holiday period. Upon expiry of the holiday period, the time switch automatically switches in accordance with the programmed switching times.
1 hour test
   The function "1H-TEST" can be used to simulate switching. When the "1H-TEST" is activated, the switch outputs are switched for one hour. At the end of this time, the time switch
   automatically switches in accordance with the programmed switching times.
PIN code
   Input and programming can be disabled via a four-digit "PIN code". The inhibit can also be cancelled with the "PIN code". The inhibit can additionally be cancelled via the "RESET"
   function; in this case, all settings and programs are also deleted.
The relay ON time and date of the last reset are displayed.
Contrast
   The 1-channel AstroRex has a control input with variable delay-time. The control input permits additional switching by the relay in parallel to the switching program. Variable delay-time
   0 min - 23 h 59 min; the delay-time begins as soon as the voltage at the control input drops.
Data key
   The menu item "KEY - READ - WRITE" is automatically activated if a data key is inserted when the power supply is connected.
   "WRITE": Program data are transferred from the time switch to the data key.
   Important: Data already saved on the data key are overwritten.
   "READ": Program data are transferred from the data key to the time switch. Any switching programs already saved in the time switch are overwritten.
   The number of programs in the time switch and the basic settings can be saved in the time switch and on the data key. Example: AstroRex D21 maximum 28 programs plus basic set-
   tings.
   When working without power supply connected, the menu item "KEY - READ - WRITE" is not activated automatically when a data key is inserted. The "KEY" function must be selected via
   the menu and the required function can then also be executed without a power supply.
 PC programming
   In addition to simple, menu-based programming directly on the time switch, switching programs and basic settings for the AstroRex can also be compiled on a personal computer with
   the Rex software AlphaSoft and transferred to the time switch with a data key. A read/write device (part number 047 73) is needed to transfer switching programs and settings compiled
   on the personal computer to the data key. The device is connected to the personal computer via the USB port. The read/write device is supplied together with a CD-ROM containing the
   AlphaSoft program and the necessary driver. System requirements for the personal computer: USB port, Windows 98 second edition, Windows 2000 or Windows XP, 40 MB free
   memory capacity on the system drive.
Reset
   Pressing simultaneously on all 4 buttons for more than 2 seconds, will cause a deletion of all stored data. Language, date/time, summer / winter time and switching programs will need
   to be reinstalled.
                                                                                                                                                                                          9
 Rex - digital time switches
 AlphaRex DY64
                                               NEW
                                                                                                  The AlphaRex DY64 offers 3 different types of programming:
                                                                                                  Weekly Program
                                                                                                  This menu item is provided for the simple input of programs which are to be repeated
                                                                                                  weekly (such as switching of lights and boilers). A weekly program consists of an ON time,
                                                                                                  an OFF time and the associated ON and OFF days.
                                                                                                   MON TO SUN: the days of the week are already assigned and you only need to set
                                                                                                    the ON and OFF times. This is used where the same program is to be executed on every
                                                                                                    day of the week.
                                                                                                   INDIVIDUAL: you can assign the ON and OFF times to any desired days.
                                     A41 163                                                        This is used where the same program is to be executed only on certain days of the week
                                                                                                    or different programs are to be executed on the various days.
  Reference
                                                                                                  Yearly Program
              AlphaRex DY64                                                                       This menu item permits the input of (additional) annual programs which are to be executed
              annual time switch, 4 channels                                                      only during a specified period. These programs and the weekly programs of the same chan-
 A41 163 120/230 V, 50/60 Hz                                                                      nel are programmed together as described above. The period during which a program is to
 A41 164 24 V, AC/DC                                                                              be executed is defined by entering a start date and an end date.
         Accessories                                                                               The option EVERY YEAR should be selected if the additional program is to be executed
 A40 125 Data key for DY64 (NOT identical to A40 107!)
 A40 126 Replacement battery                                                                        during the same period of each year (e.g. Christmas, national holidays, birthdays, etc.).
                                                                                                   The option ONCE should be selected if the additional program is to be executed only
                                                                                                    during a single period (e.g. vacation period), but the start and end dates of this period are
      According to UL 60730-1, UL 60730-2-7, VDE 631-1 and 631-2-7, IEC 60 730-1                    different in each year.
      and 60 730-2-7, EN 60 730-1 and 60 730-2-7
10
                              Rex - digital time switches
                              AlphaRex DY64
Exceptional Program
The weekly and annual programs defined for a channel are not executed as long as an extra         Technical data
program is active. However, other exception programs will be executed while an exception
                                                                                                  Type                                                                                                                AlphaRex
program is active. The various exception programs are programmed together as described                                                                                                                                  DY64
above. (see OR function 3a)                                                                       No. of pitch units of 17.5 mm                                                                                           6
                                                                                                  Number of channels                                                                                                      4
 The option EVERY YEAR should be selected if the exception program is to be activated for        Power reserve                                                                                                        5 years
  the same period in each year (e.g. Christmas, national holidays, birthdays, etc.).              Switching increment                                                                                                   1 sec
                                                                                                  Shortest switching time                                                                                               1 sec
 The option ONCE should be selected if the exception program is to be activated only             Accuracy                                                                                                        0.2 sec/day/ or frequency
  during a single period (e.g. vacation period), but the start and end dates of this period are   Switching capacity
  different in each year.                                                                          Resistive 230 V~cos j =1                                                                                           16 A~
                                                                                                   Incandescent lamp 230 V                                                                                              8 A~
 Option MON TO SUN: the exception program is active from 00:00 hours on the start date            Inductive 230 V~cos j =0.6                                                                                         10 A~
  to 24:00 hours on the end date. During this period, the output of the related channel           Switch output                                                                                                       4 SPDT
  switches only as defined in the exception program.                                              Programs1)                                                                                                      3 x 4 x 28 (336)
                                                                                                  Control input with delay-time                                                                                       0 min 
 Option INDIVIDUAL: the exception program is active from 00:00 hours on the start date
                                                                                                                                                                                                                    23 h 59 min
  to 24:00 hours on the end date. During this period, the output of the related channel           Operating temperature                                                                                           20 C+55 C
  switches only as defined in the exception program.                                              Protection                                                                                                            IP20
 Option PROG ON: the exception program is active from the ON time on the start date
  to OFF time on the end date. During this period, the output of the channel is permanently            1)
                                                                                                            Each program comprises a switch-on and switch-off
  on.                                                                                                       time and the associated on and off days or day blocks.
 Option PROG OFF: the exception program is active from the ON time on the start date to
  OFF time on the end date. During this period, the output of the channel is permanently off.
                                                                                                  Dimensions
Cycle function for channel 1
Instead of its STANDARD function, the output of channel 1 can be switched on and off cycli-
cally. The available parameters are the PERIOD and the                                                                                                   1       4            2           1       4
                                                                                                                                                 2
                                                                                                                                                     1               2
                                                                                                                                                         ON                  ON
                                                                                                                                                                                                                         83 mm
                                                                                                                                                         AUTO                AUTO
                                                                                                                                                                                                                          3.27
                                                                                                                                                         OFF                 OFF
                                                                                                                                                                                                  +
                                                                                                                                                     3               4
                                                                                                                                                         ON                  ON
                                                                                                                                                         AUTO                AUTO
                                                                                                                                                         OFF                 OFF
120V/230V~50/60Hz
                                                                                                                                                         1       4
                                                                                                       L    M   N S Ch1                      3
                                                                                                                                                 2                            2           1       4
                                                                                                                                                                                                      4
                                                                                                            
                                                                                                                                                   4.24                                                                                       2.6
                                                                                                                                                 107.7 mm                                                                                     66 mm
Wiring diagram
                                                                                                                                                             2           1        4           2       1   4
                                                                                                                                   047 70
                                                                                                                    M     120V/230V 50/60Hz
                                                                                                                         R6a -20T
                                                                                                                                                                     1                2
                                                                                                                                                                         ON               ON
                                                                                                                                                                                                          +
                                                                                                                                                                         AUTO             AUTO
                                                                                                                                                                         OFF              OFF
                                                                                                                                                                     3                4
                                                                                                                                                                         ON               ON
                                                                                                                                                                         AUTO             AUTO
                                                                                                                                                                         OFF              OFF
120V/230V~50/60Hz
                                                                                                                                                                         1        4
                                                                                                                         L    M    N S Ch1               3
                                                                                                                                                             2                                2       1   4
                                                                                                                                                                                                              4
                                                                                                                              
                                                                                                                                                                                                                                                      11
 Rex - digital time switches
 MicroRex / MicroRex Plus
NEW
      Additional features:
       manual override (ON/OFF): permanent ON or OFF
                                                                                                                   86 mm
                                                                                                                    3.39
                                                                                                                                                                        45 mm
                                                                                                                                                                         1.77
       automatic override (ON/OFF): actual program will be inverted (ON->OFF,
        OFF->ON) until next programmed ON time
       automatic changing of summer/winter time (daylight saving)
       running reserve of 6 years
              1   2
                                                                                                               83 mm
                                                                                                                                                                              45 mm
                                                                                                                3.27
1.77
4 3
                                                                                                                                                           2.6
                                                                                                                                                          66 mm
12
                                  Rex - digital time switches
                                  Front panel and wall mounting
                                  MaxiRex Plus
NEW
A44 210
     Example:
     1. prog.:        ON 07:00h          OFF 08:15h            Mo-Fr       CH1                Overview                                Wall mounting
     2. prog.:        ON 16:00h          OFF 20:15h            Mo-Su       CH2
     2. prog.:        ON 10:00h          OFF 15:15h            Fr          CH1+2
                                                                                                                                          38 mm
                                                                                                                                           1.49
     Additional features:
      manual override (ON/OFF): permanent ON or OFF                                                              MEN
                                                                                                                     U
                                                                                                                         OK
      automatic override (ON/OFF): actual program will be inverted (ON -> OFF,
       OFF -ON) until next programmed on time.
      automatic changing of summer/winter time (daylight saving)
      running reserve: 6 years
Dimensions
                 2.83                                 1.73
                72 mm                                 44 mm
                                                                                                                                                          1
                                                                                                                                                       2.6 mm
                                                                                                                                                       66.4
                                        66 mm
                                       2.60
                              110 mm
                               4.33
OK
                                                                                                                                                                   U
                                                                                                                                                                MEN
Ref. 044 09
              2.71                                1.33
             69 mm                                34 mm
                                                                                                                                                                            13
Rex - analog time switches                                                            Rex - analog time switches
MicroRex - 3 modules for DIN rail mounting                                            MicroRex - 1 module for DIN rail mounting
14
                           Rex - analog time switches
                           MicroRex
                                                                                                           2.07                                  1.73
                                                                                                          52.6 mm                                 44 mm
                                                                                                                                                               45 mm
                                                                                                                                 104.9 mm
                                                                                                                                                                2.6
                                                                                                                                   4.13
       U1 U2 1 4 2
                                                                                                                    0
                                                                                                             0.69                              1.73
                                                                                                            17.5 mm                            44 mm
                                                                                                 86 mm
                                                                                                  3.39
                                                                                                                                                             45 mm
                                                                                                                                                              1.77
                                                                                                                                                                       15
 Rex - analog time switches
 Front panel and wall mounting
 EconoRex M
                                                                                         Technical data
                                                                                         Type                                              EconoRex         EconoRex           EconoRex        EconoRex
                                                                                                                                           MT               MQT                MW              MQW
                                                                                         Motor                                               synchron          quartz            synchron         quartz
                                                                                         Switching dial                                                  24 h                                7d
                                                                                         Running reserve                                         none             >100 h           none           >100 h
                                                                                         Switching step                                                10 min                               1h
                                                                                         Min. switching time                                           20 min                               2h
                                                                                         Switching accuracy                                          +/-5 min                            +/-30 min
                                           912 441                                                                                           according      +/-2.5 sec         according        +/-2.5 sec
                                                                                         Accuracy                                          to frequency       a day            to frequency a day
                                                                                         Switching capacity
                                                                                          Resistive 230 V~ cos  =1                             20 A~            16 A~           20 A~             16 A~
Reference
                                                                                          Incandescent lamps 230 V~                                      4 A~                               4 A~
                                                                                          Inductive 230 V~ cos  =0.6                                   12 A~                              12 A~
                     Time switch modules with flat plugs for                             Contacts                                                                       1 SPDT
                     panel mounting (without accessories)                                Operating temperature                                                        -10....+55 C
                                                                                         Protection                                                                       IP30
                     EconoRex MT
                     24 h, without running reserve
                                                                                         Dimensions
 912 441 230 V, 50 Hz
 A12 463 120 V, 60 Hz                                                                                          2.83                                                  1.32
                                                                                                               72 mm                                                 35.5 mm
                     EconoRex MQT
                                                                                                                                                                     0.83
                     24 h, with running reserve                                                                                                                     21mm
                                                                                                                                                          67 mm
                                                                                                                                                          2.64
                                                                                                                                        72 mm
                                                                                                                                         2.83
                     EconoRex MW
                     7 day, without running reserve
                     EconoRex MQW
                     7 day, with running reserve
              Compact analog daily or weekly time switch for front panels and
              surface mounting
               with manual override
               with 72 x 72 mm display conform to DIN EN 50 022 part C
                R3
  68 mm+0.7
 2.67
                                                                                                     1
                                                                                                 2 .7 m
                                                                                                     m
                                                                                                 69
                                                                                   2
                                                                                2.1 mm
                                                                                  54
Ref. 495 94
16
                                                  Rex - analog time switches
                                                  MaxiRex 30A
NEW
A23 460
      Robust analog daily and weekly time switch with REAL 30 Amp switching capacity,
      for DIN rail mounting and wall mounting.
     The MaxiRex 30A is our perfect solution to control your special applications with
     heavy loads like:
      the lighting of commercial billboards / sign boards
      water heaters
      hydrochlorinators
      heating / ventilation systems
      post lights
      blowers
      pool heaters
      electric fences                                                                                                                                                      Dimensions with terminal cover
      filters, pumps and conveyers                                                                                                                                                                  2.83                    2.04
                                                                                                                                                                                                                             52 mm
                                                                                                                                                                                                    72 mm
112.2 mm
     POWER
                                                                                       4.30
4.41
                 POWER           LOAD
             L           N   N          L
POWER
                                                                                                            POWER           LOAD
                                                                                                        L           N   N          L
 L
 N                                                                                                                                                                                                                                            17
 Rex - analog time switches
 defrost time switches
 PolarRex
Technical data
                                                                                                                                                                          14
                                                                                                                            24 23
                                                                                                                                                                                                                                                                                         72 mm
                                                                                                                                                                           11
                                                                                                                                                                                                                                                                                          2.83
                                                                                                                                 2
                                                                                                                                                                          10
                                                                                                                                     3
                                                                                                                                                     6
              Defrost time switches with running reserve
                                                                                                                                                                      9
                                                                                                                                                                                                                               113.7 mm
                                                                                                                                          4
                                                                                                             min.                              5             8                          min.
                                                                                                                                                    6    7
                                                                                                                                                                                                                                 4.47
                                                                                                                    10                                                             10
                                                                                                                                                                                        30 60
                                                                                                                         30 60
                                                                                                                                                                               5
                                                                                                             5
                                                                                                                                                                               1
                                                                                                             1
                                                                                                                 1                                                                 2
              PolarRex QKT                                                                                                            1                          STOP               2
              24 hour, 1 channel
                                                                                                                    L N 1 2 3 4 5 6
24 hour, 2 channels
                                                                                                                                    Programming
      According UL 60730-1, UL 60730-2-7, IEC 730-1, EN 60730-1,
      VDE 0631-1, IEC 730-2-7, EN 60730-2-7, VDE 0631-2-7.
      The time switch has a 24h dial and one (1 channel) or two (2 channel)
      continuously adjustable short time programs, which can repeated several
      times in 24h. The programs duration has to be adjusted with a button
      which is dedicated to a specific channel. The start of the program has to be
      set on the dial by pulling a segment on the desired time. The shortest
      duration between 2 programs is 30 min. The short time program can be
      repeated up to 48 times in 24h. The beginning, the duration and the
      number of the programs can be changed easily without any accessories.                                                                                                    Programming the defrost times and visualization of the
                                                                                                                                                                               working status with 2 green LEDs
      Different types of mounting:
       DIN rail
       wall
                                         DIN-rail                                                                                Wall mounting
                                                                                                                                                                        1. 
                                                                                                                                                                      28.512
                                                                                                                                                                          mm
                                                                                                                                                                                                                                .137 x 1.57
                                                                                                                                                                                                                                3.5mm x 40mm
                                                                                                                                                         89 mm
                                                                                                                                                          3.50
                                                                                                                                                                                                       10
                                                                                     10
                                                                                          30
                                                                                                                                                                                                            30
                                                                                           60
                                                                               1 5
60
                                                                                                                                                                                                                     10
                                                                                                                                                                                                                 5
                                                                                                                                                                                                                          30
                                                                                                                                                                                                                 1
60
                                                                    10
                                                                         30
                                                                          60
                                                              1 5
                                                                                                                                                                                                                                    .137 x 1.18
                                                                                                                                                                                                                                    3.5mm x 30mm
18
                            Rex - analog time relays
Reference Reference
Contact Contact
A63 209 Clock generator relay (impulse starting) Flasher (off-time starting)
Contact Contact
Contact Contact
Additive fleeting ON
    According to UL 60730-1, UL 60730-2-7, VDE 0631-1 and 0631-2-7, EN 60 730-1                        Control input Y1
    and 60 730-2-7                                                                                     Contact
    Application:
    To control single timer functions like:
    illumination, ventilation, automation, control systems . . .
     sealable cover
     supply voltage: 12 V...230 V AC
                                                                                                                                                                     19
 Rex - analog time relays
Technical data
                                                                  Wiring diagram                            7 domains of time:
 Type                                    Time relays
                                                                  83 mm
                                                                   3.27
                                                                                                                             45 mm
                                                                                                                              1.77
Functions and switching diagrams                                           Multifunctional relay (A63 208)
                                                                           additionally to the previous mentioned functions, (except flashing
                                                                           relay) the multifunctional relay offer the following functions:
ON-delay relay                                          A63 205            ON/OFF delay
Contact Contact
Contact Contact
Contact Contact
Contact Contact
Contact Contact
Additive fleeting ON
Control input Y1
Contact
20
                             Hour counters
                             Front panel, Din-rail, flush-mounting
                             ContaRex
Dimensions
495 54      120 V, 60 Hz
495 57      230 V, 60 Hz
                                                                                                              45 mm
495 60      10 - 80 V, DC
                                                                                                               1.77"
            ContaRex 36 x 24 front panel
    According to UL 863, cUL C22.2, IEC 1010-1, EN 61010-1, VDE 0411 part 1
     square 48 x 48 mm, IP 40
     55 x 55 adapter included (48 x 48 mm version)
     AC-version: = 0 to 99999.99 h
     DC-version: = 0 to 999999.9 h
     front panel mounting
                                                                                                     45 mm
                                                                                                      1.77"
0006723 h
Reference
                                                                                         1.89"                                          1.96"
                                                                                        48 mm                                          50 mm
            ContaRex round,  80 mm                                                      2.16"
                                                                                                                        1.77"
                                                                                        55 mm                          45 mm
    According to UL 863, cUL C22.2, IEC 1010-1, EN 61010-1, VDE 0411 part 1
     round,  80 mm, IP 67
     protected against vibrations by a rubber buffer ring
     DC-version: 0 to 99999.9 h
     front panel mounting                                                            3.14"                                 2"         .7"
                                                                                     80 mm                                51 mm      18 mm
                                                                              ContaRex 36x24
                                                                                                     22mm x33mm
                                                                                                      .866"x1.29"
                                                                                                        24 mm
                                                                                                         .944"
                                                                                     1.41"                             .31"
                                                                                    36 mm                              8mm             2.16"
                                                                                                                                      55 mm
                                                                                                                                                              21
 Hour counters
 Din-rail mount
 Rex 2000 HC2
961 103
Dimensions
Reference
                                                                                       83 mm
                                                                                        3.27
         According to UL 863, cUL C22.2, IEC 1010-1, EN 61010-1, VDE 0411 part 1
                                                                                                                     45 mm
                                                                                                                      1.77
         Analog modular hour run indicator in for DIN rail mounting
          easy and quick mounting on DIN rail by using the 2 locking clamps
          sealable cover
22
Notes
        23
                Baco Controls, Inc.
           P.O. Box 570, Cazenovia, NY 13035
       Phone: (315) 655-8372 Fax: (800) 356-3981
Web: www.bacocontrols.com Email: sales@bacocontrols.com