POWER, PROTECTION & PRECISION PRODUCTS
CONDENSED CATALOG
4 AIRPAX Bimetal Thermostats
5 KLIXON Bimetal Thermostats & Air Sensors
7 AIRPAX Temperature Sensors & Combo Sensors
8 AIRPAX Hydraulic Magnetic Circuit Breakers & Modular Distribution Systems
11 KLIXON Thermal Circuit Breakers & Protectors
15 NSS LINEGARD Ground Fault Circuit Interrupters
17 DIMENSIONS DC to AC Power Inverters
ISO 9001 certified, Sensata Technologies is a global leader in providing world-class customer service, leading-edge
technology innovation, and continuous improvement in every product and service we offer to our customers.
With strategic partnerships with North Shore Safety Ltd, Sensata Power Protection provides your company with an
unprecedented offering of high quality components and integration systems at reasonable cost to you.
Our products include hydraulic-magnetic circuit breakers and protectors, thermal circuit protectors, bimetal thermostats,
temperature sensors, DC to AC inverters, speed and position sensors, fuses, power switches, ground fault circuit interrupters,
and modular distribution systems.
Our products are found in many of todays global markets, including telecommunications, industrial, recreational vehicles,
HVAC-R, marine, military, medical, information processing, electronic power supply, power generation, over-the-road trucks,
construction, agricultural, and alternative energy applications.
Sensata strives for constant improvement for the environment as well. Sensata has significantly lessened its impact on
the environment through environmental management systems including recycling, waste prevention, pollution prevention,
water use reduction programs and community outreach programs. All Sensata manufacturing (make) facilities have been
awarded, or are working toward ISO 14001 certification, and we are committed to meeting the RoHS lead-free compliance
standards wherever required by our customers.
BIMETAL THERMOSTATS
AIRPAX 6600 & 6700 Series
General Description Operating Switch Range Max Current and Voltage Rating Approvals
8-pin DIP or TO-220 international package standard 40C to 130C (104F to 266F) Up to 0.5 amp at 48VDC cUus recognized
Ideal for surface and air sensing on PC boards 0.001 to 0.2 amp at 5VDC VDE approved (upon request)
RoHS compliant per EU directive 2002/95/EC (gold contacts)
Gold-plated contacts
30,000 life cycles @ max standard amperage
100,000 life cycles @ max gold contact amperage
AIRPAX 5003 Series
General Description Operating Switch Range Max Current and Voltage Rating Approvals
1/2 button, environmentally sealed 35F to 325F (2C to 163C) 5 amp at 120VAC cUus recognized
Ideal for applications where space is at a 3 amp at 240VAC / 24VDC
premium 1.5 amp at 48VDC
RoHS compliant per EU directive 2002/95/EC
AIRPAX 5004 Series
General Description Operating Switch Range Max Current and Voltage Rating Approvals
1/2 button, environmentally sealed 35F to 325F (2C to 163C) 15 amp at 120VAC cUus recognized
Ideal for applications where high amperage 10 amp at 240VAC VDE approved
switching is required
RoHS compliant per EU directive 2002/95/EC
AIRPAX 4100 Series
General Description Operating Switch Range Max Current and Voltage Rating
Brass construction, NEMA 4 & 13 (IP67), SPST 40C to 130C (104F to 266F) 1 amp at 120VAC & 48VDC, 30K cycles
Available as grounded or isolated case 3 amp at 28VDC, 5K cycles
Ideal for industrial system applications in which
low-cost and reliability is the priority
RoHS compliant per EU directive 2002/95/EC
AIRPAX 5011 Series
General Description Operating Switch Range Max Current and Voltage Rating
1/2 button, hermetically sealed package, SPST 140F to 480F (60C to 249C) 3 amp at 120VAC isolated case
Ideal for surface and immersion sensing for 3 amp at 32VDC grounded or isolated case
industrial system applications in which
construction must have a hermetic seal
RoHS compliant per EU directive 2002/95/EC
AIRPAX 5020 Series
General Description Operating Switch Range Max Current and Voltage Rating
Grounded case, stainless steel, hermetically 35F to 480F (2C to 249C) 3 amp at 32VDC
sealed, SPST
Ideal for immersion sensing in industrial system
applications in which construction must have a
hermetic seal
RoHS compliant per EU directive 2002/95/EC
4 Airpax & Klixon - Bimetal Thermostats http://www.sensata.com/
BIMETAL THERMOSTATS
AIRPAX 5100 Series
General Description Operating Switch Range Max Current and Voltage Rating Approvals
Isolated case, stainless steel, hermetically 35F to 480F (2C to 249C) 5 amp at 120VAC cUus recognized
sealed, SPST 2.5 amp at 240VAC
Ideal for immersion sensing in industrial system
applications in which construction must have a
hermetic seal
RoHS compliant per EU directive 2002/95/EC
KLIXON 3BT & 4BT Series
General Description Operating Switch Range Max Current and Voltage Rating Approvals
Tiny Stat precision thermostat 0F to 350F (-18C to 177C) 1 amp at 115VAC & 30VDC 3BT: MIL-PRF-24236/19
Single pole, single throw (SPST) 0.01 amp at 30mVAC & 30mVDC 4BT: MIL-PRF-24236/13
Hermetically sealed and back-filled with nitrogen (gold contacts, min amps)
Gold-plated contacts available upon request 0.5 amp at 30VAC & 30VDC
10,000 life cycles 0.2 amp at 115VAC
(gold contacts, max amps)
KLIXON 5BT Series
General Description Operating Switch Range Max Current and Voltage Rating Approvals
bimetal disc thermostat, hermetically sealed -65F to 400F (-54C to 204C) 2 amp at 125VAC & 30VDC for MIL-PRF-24236 /24
Single pole, double throw (SPDT) 100,000 cycles
High resistance to shock and vibration 3 amp at 125VAC & 30VDC for
50,000 cycles
KLIXON M1, 11041 Series
General Description Operating Switch Range Max Current and Voltage Rating Approvals
bimetal disc thermostat, hermetically sealed -65F to 550F (-54C to 288C) 5 amp at 30VAC & 30VDC at MIL-PRF-24236/1
Single pole, single throw (SPST) 100,000 cycles
High resistance to shock and vibration 6 amp at 125VAC at
5,000 cycles
Other amperages, voltage,
cycles are available
KLIXON M2 Series
General Description Operating Switch Range Max Current and Voltage Rating Approvals
bimetal disc thermostat, hermetically sealed 0F to 300F (-18C to 149C) 2 amp at 120VAC & 30VDC at MIL-PRF-24236/20
Single pole, single throw (SPST) 250,000 cycles S-311-641
Low profile, narrow differential
KLIXON 4344 Series
General Description Operating Switch Range Max Current and Voltage Rating Approvals
bimetal disc thermostat, hermetically sealed -65F to 550F (-54C to 288C) 7 amps, 30VAC/VDC at CUL recognized (#34618)
Single pole, single throw (SPST) 5,000 cycles
Many option available, including switch packaged 3 amps, 125VAC at
into probe and strap mount options 50,000 cycles
Other amperages, voltage,
cycles are available
http://www.sensata.com/ Airpax & Klixon - Bimetal Thermostats 5
BIMETAL THERMOSTATS & AIRFLOW SENSORS
KLIXON 7BT2 Series
General Description Operating Switch Range Max Current and Voltage Rating Approvals
Environmentally sealed, high capacity, 30F to 400F (-1C to 204C) 10 amps, 120VAC / 240VAC UL & CUL recognized (#34618)
bimetal disc up to 100,000 cycles
SPST, normally open or closed 7 amps, 277VAC
up to 100,000 cycles
KLIXON 6786 Series
General Description Operating Switch Range Max Current and Voltage Rating Approvals
Environmentally sealed, low-profile, bimetal disc -20F to 350F (-29C to 177C) 7 amps, 30VAC/VDC at UL & CUL recognized (#34618)
SPST, normally open or closed 5,000 cycles
3 amps, 125VAC at
50,000 cycles
Other amperages, voltage,
cycles are available
KLIXON Probe Packages
General Description Operating Switch Range Max Current and Voltage Rating Approvals
Extreme temperature probes (up to 550F), fast Extreme temperature: Extreme temperature: Extreme temperature,
response probes and narrow differential probes -65F to 550F (-54C to 288C) Up to 7 amps, various voltages 28303 series only:
(2F to 8F reset differential) are available Fast response: Fast response: UL / CUL recognized
0F to 350F (-18C to 177C) Up to 1 amp at 115VAC & 30VDC (#E34618)
Narrow differential: Narrow differential:
0F to 275F (-18C to 135C) Up to 2 amp at 125VAC & 30VDC
AIRFLOW SENSORS
KLIXON Airflow Sensors
General Description Operating Temperature Range Max Current and Voltage Rating Approvals
Solid-state airflow sensors are designed to 10C to 50C (50F to 122F) 0.40 amp at 30VDC Military
recognize loss or reduction of airflow in power Aerospace
supplies, data processing units, commercial and Commercial
military electronic equipment
Ideal for even the dirtiest of environments
SPST or SPDT, normally open or closed
6 Klixon - Bimetal Thermostats & Air Flow Sensors http://www.sensata.com/
TEMPERATURE & SPEED SENSORS
BIMETAL THERMOSTAT + TEMPERATURE SENSOR
AIRPAX 6024 Series
General Description Max Switch Current and Voltage Rating
Stainless steel or brass, epoxy sealed, SPST 1 amp at 120VAC & 48VDC
Bimetal thermostat and temperature sensor in
one package Operating Switch Range
Ideal technology combination for industrial 40C to 120C (104F to 248F)
applications where engine ports are at a premium
Operating Sensor Range
-40C to 120C (-40F to 248F)
Additional sensor options available
TEMPERATURE SENSORS
AIRPAX 3000 Series
General Description Max Operating Sensor Range Available Sensors
Chose from standard stainless steel -40C to 125C (-40F to 257F) Thermistors
air, surface, and immersion sensor RTDs
package configurations ICs
AIRPAX 5024 Series
General Description Max Operating Sensor Range Available Sensors
Customer specified package -50C to 300C (-58F to 572F) Thermistors
configurations for air, surface, and RTDs
immersion sensing ICs
http://www.sensata.com/ Airpax - Temperature & Speed Sensors 7
CIRCUIT BREAKERS & CIRCUIT PROTECTORS
AIRPAX IAR / IER / IUR / CER / CUR Series
General Description Max. Poles Current and Voltage Rating Interrupting Capacity Approvals* (pending)
RU / 1RU hydraulic-magnetic circuit protection 2 2 to 50 amps, 80VDC & 250VAC up to 5000 amps cULus
Snap-acting trip mechanism increases UL1077
operational life UL489A Listed
Auxiliary switch options available for alarm TUV approved
signalling
AIRPAX T / R / PP / PR / CPP / CPR / CR (SNAPAK) Series
General Description Max. Poles Current and Voltage Rating Interrupting Capacity Approvals*
Compact hydraulic-magnetic circuit protection 2 0.10 to 7.5 amps at 50 VDC and 250 VAC 1000 amps UL 489A listed
Snap-acting trip mechanism increases 0.10 to 30 amps at 32 VDC UL recognized
operational life 0.10 to 30 amps at 120 VAC CSA certified
Aesthetically pleasing for front panel mounting 0.10 to 25 amps at 120/240 VAC (two poles) TUV approved
Toggle, rocker, push-pull, push-to-reset 0.10 to 20 amps at 250 VAC VDE approved
actuation options (50/60 Hz, at 500AIC) CE compliant
0.10 to 20 amps at 65 VDC (two poles) CCC approved
500AIC
AIRPAX AP / UP, AP-MIL Series
General Description Max. Poles Current and Voltage Rating Interrupting Capacity Approvals*
QPL to MIL-PRF-39019 3 AP ratings AP ratings MIL-PRF-M39019
Sealed hydraulic-magnetic circuit protection 0.05 to 20 amps at 50 VDC and 240 VAC 500 amps, UL recognized
Can withstand 100G shock repeatedly 50 VDC, 120 VAC (UP type only)
Tolerates 10G vibration from 10 to 2000 Hz under UP ratings (single pole only) 300 amps, 240 VAC FM approved
full load 0.05 to 20 amps at 50 VDC (UP type only)
Ideal for use in Class 1, Div. 2, Groups A, B, C, D 0.05 to 15 amps at 120 VAC UP ratings
hazardous locations 0.05 to 7.5 amps at 240 VAC 1000 amps,
50VDC, 240 VAC
AIRPAX IPA / CPA Series
General Description Max. Poles Current and Voltage Rating Interrupting Capacity Approvals*
Compact hydraulic-magnetic circuit protection 3 0.05 to 30 amps at 65 VDC 1000 amps UL 489A listed (CPA)
Quick-connect, screw, PC board mount 0.05 to 20 amps at 80 VDC (300 AIC) UL recognized
terminals available 0.05 to 25 amps at 250 VAC, 50/60 Hz CUR recognized
Auxiliary switch options 25.1 to 30 amps at 240 VAC, 50/60 Hz TUV certified
Multi-pole versions with multi or single handle 0.10 to 15 amps at 250 VAC, 400 Hz CE compliant
options 0.05 to 25 amps at 65 VDC (TUV) CCC approved
0.05 to 25 amps at 250 VAC, 50/60 Hz (TUV) (pending)
0.05 to 15 amps at 250 VAC, 400 Hz (TUV)
AIRPAX IAG / IUG / IEG / CEG / LEG Series
General Description Max. Poles Current and Voltage Rating Interrupting Capacity Approvals*
Hydraulic-magnetic circuit protection 6 0.05 to 50 amps at 80 VDC 5000 amps, 240 VAC, 50/60 Hz UL 489 listed (LEG)
IEG versions meet IEC spacing requirements for 0.05 to 50 amps at 240 VAC 1500 amps, 250 VAC, 400 Hz UL 489A listed (CEG)
installation in equipment that must comply with 0.05 to 30 amps at 277 VAC, 50/60 Hz 7500 amps, 80 VDC (IEG) UL recognized
IEC 601 and 950, and VDE 0730, 0804, 0805 0.05 to 30 amps at 250 VAC, 400 Hz 5000 amps, 80 VDC (CEG) CSA certified
Multi-pole versions with multi or single handle 0.05 to 30 amps at 125 VAC, 50/60 Hz 2000 amps, 250 VAC, VDE approved
options 1 to 30 amps at 120/240 VAC, 50/60 Hz 50/60 Hz (VDE) (IEG, CEG, LEG)
Auxiliary switch options 4000 amps, 80 VDC (VDE) CE compliant
Mid-trip handle option 5000 amps, 125 VAC, CCC approved
Snap-in mounting option 50/60 Hz (LEG) UL 1500 certified
Dual frequency delay options 5000 amps, 120/240 VAC, QPL to MIL-PRF-55629
50/60 Hz (LEG)
8 Airpax - Circuit Breakers & Protectors http://www.sensata.com/
CIRCUIT BREAKERS & CIRCUIT PROTECTORS
* Consult factory for conditions of acceptability
AIRPAX LEGA Series
General Description Max. Poles Current and Voltage Rating Interrupting Capacity Approvals*
Low-depth hydraulic-magnetic circuit 2 1.00 to 30.0 amps at 120 VAC/240VAC up to 5,000A UL489
protection 1.00 to 50.0 amps at 80VDC UL
Same ratings as our LEG series TUV
Designed to minimize PDU intrusion into CE
equipment rack space
Meets UL60950 & EN60950 ITE requirements
Short toggle & flat rocker actuator options
Rear access screw terminals
AIRPAX IAL / IUL / IEL Series
General Description Max. Poles Current and Voltage Rating Interrupting Capacity Approvals*
Hydraulic-magnetic circuit protection 6 0.05 to 100 amps at 65 VDC 5000 amps, UL recognized
IEL versions meet IEC spacing requirements 0.05 to 70 amps at 80 VDC 240 VAC, 50/60 Hz CSA certified
for installation in equipment that must comply 0.05 to 50 amps at 250VDC 1500 amps, VDE approved (IEL)
with IEC 601 and 950 and VDE 0730, 0804, 0805 0.05 to 50 amps at 300VDC 250 VAC, 400 Hz CE compliant (IEL)
Multi-pole versions with multi or single handle 0.05 to 70 amps at 240 VAC, 50/60 Hz 7500 amps, 80 VDC CCC approved
actuator 0.05 to 50 amps at 277 VAC, 50/60 Hz 2000 amps, UL 1500 certified
Auxiliary switch options 0.05 to 50 amps at 277/480 VAC, 50/60 Hz 240 VAC, 50/60 Hz (VDE) QPL to
Snap-in mounting option 0.05 to 50 amps at 250 VAC, 400 Hz 2000 amps, MIL-PRF- 55629
Mid-trip handle option 415 VAC, 50/60 Hz (VDE)
Various actuator options 4000 amps, 80 VDC (VDE)
Dual frequency delay options 1200 amps,
277/480 VAC, 50/60 Hz
5000 amps, 250VDC
1000 amps, 300VDC
AIRPAX LEL Series
General Description Max. Poles Current and Voltage Rating Interrupting Capacity Approvals*
Hydraulic-magnetic circuit protection 3 0.05 to 100 amps at 80 VDC 50000 amps 80 VDC UL 489 listed
LEL versions meet IEC spacing requirements 0.05 to 50 amps at 125 VAC, 50/60 Hz 5000 amps, 125 VAC, CSA certified
for installation in equipment that must comply 0.05 to 70 amps at 120/240 VAC, 50/60 Hz 120/240 VDC 50/60 Hz VDE approved
with IEC 601 and 950 and VDE 0730, 0804, 0805 0.05 to 100 amps at 80 VDC (VDE) 2000 amps, 80 VDC CE compliant
Multi-pole versions with multi or single handle 0.05 to 50 amps at 250 VAC (VDE) 2000 amps, 250 VAC, CCC approved
actuator 50/60 Hz (VDE)
Auxiliary switch options
Snap-in mounting option
Mid-trip handle option
Various actuator options
Dual frequency delay options
AIRPAX IULP / LELP / CELP Series
General Description Max. Poles Current and Voltage Rating Interrupting Capacity Approvals*
Hydraulic-magnetic circuit protection 1 125 amps at 80 VDC 10000 amps, 80 VDC UL 489 listed
Unique, parallel current sensing design 150 amps at 80 VDC 50000 amps, 65 VDC UL 489A listed
Compact size, high current capacity 175 amps at 80 VDC (up to 150 amps) CSA certified
Auxiliary switch options 200 amps at 80 VDC 10000 amps, 80 VDC
Mid-trip handle option 250 amps at 80 VDC (> 150 amps)
251 - 300 amps at 80 VDC
Two paralleled poles
Three paralleled poles
http://www.sensata.com/ Airpax - Circuit Breakers & Protectors 9
BREAKERS & MODULAR DISTRIBUTION SYSTEMS
AIRPAX 205 / 295 / 205D Series
General Description Max. Poles Current and Voltage Rating Interrupting Capacity Approvals*
Hydraulic-magnetic circuit protection 9 0.050 to 30 amps at 277/480 VAC 5000 amps, UL recognized
Dust proof enclosure sensing design 0.050 to 60 amps at 250 VAC 250 VAC, 65 VDC CSA certified
Compact size, high current capacity 0.050 to 100 amps at 65 VDC 3000 amps, 65 VDC CE compliant
Auxiliary switch options 1500 amps, 277/480 VAC
Mid-trip handle option (30 amps max. rating)
5000 amps, 277.480 VAC
with 125 amp series fuse
AIRPAX IALR / IULR / IELR Series
General Description Max. Poles Current and Voltage Rating Interrupting Capacity Approvals*
Hydraulic-magnetic circuit protection 4 0.050 to 70 amps at 80 VDC 7500 amps, 80 VDC UL recognized
Meets IEC spacing requirements for 0.050 to 70 amps at 250 VAC, 50/60 Hz 5000 amps, CSA certified
installation in equipment that must comply 0.100 to 50 amps at 80 VDC (VDE) 250 VAC, 50/60 Hz VDE approved (IELR)
with IEC 601 and 950, and VDE 0730, 0804, 0805 0.100 to 50 amps at 2000 amps, CE compliant
Designed to mount on standard 35mm DIN 250 VAC, 50/60 Hz (VDE) 277 VAC, 50/60 Hz
rails 0.100 to 30 amps at 2000 amps at
415 VAC, 50/60 Hz (VDE) 250 VAC, 50/60 Hz (VDE)
2000 amps at
415 VAC, 50/60 Hz (VDE)
4000 amps at
80 VDC (VDE)
AIRPAX 209 / 219 / 229 / 279 Series
General Description Max. Poles Current and Voltage Rating Interrupting Capacity Approvals*
Hydraulic-magnetic circuit protection 6 0.100 to 100 amps at 160 VDC 5000 amps UL 489 listed
Front or back connected terminal styles 0.100 to 125 amps at 125 VDC 10000 amps UL 489A listed (279)
E-frame style model complies with UL 489 0.100 to 77 amps at 600 VAC 4000 amps (VDE) UL recognized
249 Power Selector Breaker system is 0.100 to 100 amps at 347/600 VAC CSA certified
listed as a branch circuit breaker per UL 489 0.100 to 100 amps at VDE approved
Complies with international requirements 120, 240, 277, 480 VAC UL1500 certified
279 complies with UL 489A CCC approved
CE compliant
AIRPAX JAE / JRE / JTE / JLE Series
General Description Max. Poles Current and Voltage Rating Interrupting Capacity Approvals*
Hydraulic-magnetic circuit protection 6 UL489 10000 amps, 160 VDC UL 489 listed
F-frame style complies with UL 489 100 to 250 amps at 160 VDC 10000 amps, 125/250 VDC UL 489A listed
Various terminal options for design flexibility 100 to 250 amps at 65 VDC 65000 amps, 65 VDC UL recognized
Reduced voltage drop through the circuit 100 to 250 amps at 125/250 VDC 10000 amps, 240 VAC CSA certified
breaker compared to other protective 100 to 250 amps at 240 VAC 18000 amps, 240 VAC VDE approved
devices 100000 amps, 65VDC CCC approved
Auxiliary switch options UL489A (UL489A up to 800 amps) CE compliant
Mid-trip handle options 275 to 800 amps at 160 VDC
275 to 1200 amps at 65 VDC
MODULAR DISTRIBUTION SYSTEMS
AIRPAX MDS & MDS2 Series
General Description Current and Voltage Rating Max Positions
The Modular Distribution System Maximum load bus rating per 20
provides unprecedented system position is 100 amps, 125VDC
flexibility
Hot Plug modules allow for equipment expansion
without power shutdown
Unique alarm conductors simplify signal wiring
Modular load terminals available with top or rear
access
10 Airpax - Circuit Breakers & Protectors http://www.sensata.com/
CIRCUIT BREAKERS & CIRCUIT PROTECTORS
KLIXON Arc Shield Series * Consult factory for conditions of acceptability
General Description
The ArcFault Circuit Interrupters (AFCI) will detect potentially hazardous arcing conditions and prevent
catastrophic damage caused by electrical fires
Hazardous arcfault conditions can result in overheated wiring and has been shown to result in fires or cause
a loss of function on the affected circuit
Protect AC and DC electrical systems in aircraft, commercial & residential, and 42 VDC applications
KLIXON 2TC & 3TC Series, Aircraft Circuit Breakers
General Description Current and Voltage Rating Interrupting Capacity Approvals*
Thermal circuit breakers 2TC: 1A to 25A for 4 to 16 seconds 1-20 amps : 6,000 amps @ 28 VDC Mil-qualifications
28VDC or 120VAC, 1 to 35 Amps 3TC: 15A to 35A for 4 to 20 seconds 25 amps : 1,625 amps @ 28 VDC European & SAE
High vibration resistance and interrupt capacity 1-15 amps : 2,500 amps @ 120 VAC, 400 Hz standards
Ambient temperature compensation and 20 amps : 2,000 amps @ 120 VAC, 400 Hz All U.S. and most
trip-free design 24 amps : 1,800 amps @ 120 VAC, 400 Hz European aircraft
OEMs qualifications
KLIXON 5TC Series, Aircraft Circuit Breakers
General Description Current and Voltage Rating Interrupting Capacity Approvals*
Thermal circuit breakers 20A to 50A for 2 to 18 seconds 20 to 50 amps: 4000 amps at 28 VDC Mil-qualifications
28VDC or 120VAC, 20 to 50 Amps 20 to 50 amps: 2000 amps at 115 VAC, 400 Hz European & SAE
High vibration resistance and interrupt capacity standards
Ambient temperature compensation and All U.S. and most
trip-free design European aircraft
OEMs qualifications
KLIXON 6TC & 9TC Series, Three-Phase Aircraft Circuit Breakers
General Description Current and Voltage Rating Interrupting Capacity Approvals*
Thermal circuit breakers 6TC: 2A to 25A for 4 to 20 sec 2-20 amps : 2,000 amps @ 120 VAC, 400 Hz Mil-qualifications
28VDC or 120VAC, 1 to 35 Amps 9TC: 1A, 15A to 35A for 4 to 20 sec 1, 15-35 amps : 2,000 amps @ 120 VAC, European & SAE
Three-phase aircraft circuit breaker 400Hz standards
High vibration resistance and interrupt capacity All U.S. and most
Ambient temperature compensation and European aircraft
trip-free design OEMs qualifications
KLIXON 7274 & 7277 Series, Aircraft Circuit Breakers
General Description Current and Voltage Rating Interrupting Capacity Approvals*
Thermal circuit breakers 0.5A to 20A for 2 to 20 seconds to 5 amps: unlimited at 28 VDC MIL-C-5809 qualified
30VDC or 120VAC, to 20 Amps 7 to 15 amps: 2,000 amps at 28 VDC
High vibration resistance and interrupt capacity to 1 amps: unlimited at 120 VAC, 400 Hz
Non-ambient temperature compensated 2 to 5 amps: 800 amps at 120 VAC, 400 Hz
7 to 20 amps: 500 amps at 120 VAC,
400 Hz
http://www.sensata.com/ Klixon - Circuit Breakers & Protectors 11
CIRCUIT BREAKERS & CIRCUIT PROTECTORS
KLIXON 15TC Series, Three-Phase Aircraft Circuit Breakers
General Description Current and Voltage Rating Interrupting Capacity Approvals*
Thermal circuit breakers 20A to 50A for 10 to 70 seconds 20 to 50 amps: 4000 amps at 28 VDC Inactive MS90351
28VDC or 120VAC, 20 to 50 Amps 20 to 50 amps: 2000 amps at 115 VAC, 400 Hz
High vibration resistance and
interrupt capacity
Non-ambient temperature compensated
Trip-free design
KLIXON 15TC Series, Three-Phase Aircraft Circuit Breakers
General Description Current and Voltage Rating Interrupting Capacity Approvals*
Thermal circuit breakers 6TC: 2A to 25A for 4 to 20 seconds 2.5 - 50 amps : 6,000 amps @ 30 VDC (-12s) Mil-qualifications
28VDC or 120VAC, 2.5 to 100 Amps 9TC: 1A, 15A to 35A for 4 to 20 seconds 2.5 - 50 amps : 6,000 amps @ 120 VA, 400 Hz MIL-C-22715 (USAF)
Usable on large electrical systems: 2.5 - 50 amps : 4,200 amps @ 205 VA, 400 Hz
6000 amps interrupting capacity 50 - 100 amps : 3,500 amps @ 120 VAC, 400Hz
Ambient temperature compensation 50 - 100 amps : 6,000 amps @ 28 VDC
and trip-free design
KLIXON 7270 & 7271 Series, Miniature Aircraft Circuit Breakers
General Description Current and Voltage Rating Interrupting Capacity Approvals*
Thermal circuit breakers 3A to 35A for 15 to 65 seconds 4,000 amps @ 30 VDC MIL-C-5809 qualified
30VDC or 120VAC, 3 to 35 Amps 3,500 amps @ 120 VAC, 400Hz
Miniature aircraft breaker
Ambient temperature compensation and
trip-free design
Available with neck mounting or
standard cover plate
KLIXON 20TC Series, Rocker-Type Aircraft Circuit Breakers
General Description Current and Voltage Rating Interrupting Capacity
Thermal circuit breakers 3A to 35A for 10 to 130 seconds 2,000 amps at 30 VDC
30VDC or 120VAC, 3 to 35 Amps 1,000 amps at 120 VAC, 400 Hz
Versatile rocker actuator: snapon,
switch type
Panel mounting
Provides dual function (on/off) circuit
switching and protection
KLIXON 7235 & 7236 Series, Thermal Overload Sensing Controls
General Description Current and Voltage Rating
28VDC or 120VAC, 2.5 to 100 Amps 750 amps: 2,000 amp adjusted circuit
High reliability: does not switch overload current Over 50 amps: 4,000 amp adjusted circuit
Adaptable for AC, DC, singlephase, or threephase applications
Stops nuisance trips: unaffected by transient current surges
Long trouble-free operation: 20,000 operating cycles
Military approved
KLIXON 3SB Series, Simulators, single-phase, low amp, quick trip
General Description Current and Voltage Rating
High shock and viabration performance 200mA max, current draw @ 28VDC
Optional panel mount configuration, replaceable amp rating insterts 3 seconds max trip time
(reference PN # 27515 when ordering), auxiliary switch
12 Klixon - Circuit Breakers & Protectors http://www.sensata.com/
CIRCUIT BREAKERS & CIRCUIT PROTECTORS
KLIXON C Series (CM, CA, CDM, CDA) * Consult factory for conditions of acceptability
General Description Calibration : 200% rated current, 77F Interrupting Capacity Approvals*
Thermal circuit breakers 2 to 10 amps : 20 to 150 seconds Per SAE J553 and ABYC E-11 UL Listed E36869
30VDC or 120VAC, 2 to 40 Amps 12.5 to 40 amps : 5 to 55 seconds
Open and closed construction
Automatic and manual reset options
Ignition protected SAE J1171
Weatherproof SAE J553
KLIXON 7851 & 7854 Series
General Description Calibration : 200% rated current, 77F Interrupting Capacity Approvals*
Thermal circuit breakers 12.5 to 60 amps : 5 to 55 seconds Per SAE J553 and ABYC E-11 UL Listed E36869
30VDC or 120VAC, 12.5 to 60 Amps
Sealed assemblies, manual and automatic
reset options
Ignition protected SAE J1171
Weatherproof SAE J 553
KLIXON F Series (FDLM, FDLA, FDLS, FDLT)
General Description Calibration : 200% rated current, 77F Interrupting Capacity
Thermal circuit breakers 35 to 150 Amps : 8 to 100 seconds Per SAE J1625 and ABYC E-11
30VDC, 35 to 150 Amps
Weatherproof, ignition protected,
trip-free design
Meets 5000 amps @ 12VDC for interrupt
capacity per ABYC E-11, DC electrical
systems of boats
KLIXON S Series (SDLM, SDLA, SLA)
General Description Calibration : 200% rated current, 77F Interrupting Capacity Approvals*
Thermal circuit breakers 35 to 150 Amps : 8 to 100 seconds Per SAE J1625 and ABYC E-11 UL Listed (E 69772)
30VDC, 35 to 150 Amps
Open and sealed assemblies, manual and
automatic reset options
Ignition protected
KLIXON 6766-19 Series
General Description Calibration : 200% rated current, 77F Interrupting Capacity
Thermal circuit breakers 35 to 150 Amps : 8 to 100 seconds Per SAE J1625 and ABYC E-11
30VDC, 35 to 150 Amps
Manual reset
Weatherproof SAE J1625 and ideally suited
for rugged applications
Ignition protected SAE J1171
KLIXON 7855 Series
General Description Calibration : 200% rated current, 77F Interrupting Capacity Approvals*
Thermal circuit breakers 175 to 200 Amps : 8 to 100 seconds Per SAE J1625, 900A 7855-6 meets
30VDC, 175 to 200 Amps CID A-A-55571/03
Sealed assemblies, manual and automatic specifications
reset options 7855-7 meets
Ignition protected CID A-A-55571/08
specifications
http://www.sensata.com/ Klixon - Circuit Breakers & Protectors 13
CIRCUIT BREAKERS & CIRCUIT PROTECTORS
KLIXON Small Frame PD Series (PDM, PDA)
General Description Calibration : 200% rated current, 77F Interrupting Capacity Approvals*
Thermal circuit breakers 2 to 10 amps : 20 to 150 seconds Per SAE J553 and ABYC E-11 CCC certified
30VDC or 120VAC, 2 to 40 Amps 12.5 to 40 amps : 8 to 50 seconds
Sealed assemblies, available in manual
and automatic reset options
Ignition protected
KLIXON Large Frame PDL Series (PDLM, PDLA)
General Description Calibration : 200% rated current, 77F Interrupting Capacity Approvals*
Thermal circuit breakers 35 to 150 Amps : 8 to 100 seconds Per SAE J1625 and ABYC E-11 PDLM meets
30VDC, 35 to 150 Amps CID A-A-55571/04
Sealed assemblies, available in manual PDLA meets
and automatic reset options CID A-A-55571/07
Ignition protected UL Listed (E 36869)
CCC certified
KLIXON PS Series (PSM, PSA)
General Description Calibration : 200% rated current, 77F Interrupting Capacity Approvals*
Thermal circuit breakers 10A for 20 to 150 seconds Per SAE J553, 600A PSM meets
30VDC, 2 to 35 Amps >10A for 8 to 50 seconds CID A-A-55571/06
Available in manual and automatic PSA meets
reset options CID A-A-55571/05
Ignition protected
KLIXON PS Neck Mounting Series (PSM-XX-N)
General Description Calibration : 200% rated current, 77F Interrupting Capacity Approvals*
Thermal circuit breakers 2 to 10 amps : 20 to 150 seconds Per SAE J553 and ABYC E-11 CCC certified
30VDC, 2 to 35 Amps 12.5 to 35 amps : 8 to 50 seconds
Sealed assemblies, available in manual
and automatic reset options
Ignition protected
KLIXON 9115 Series
General Description Calibration : 200% rated current, 77F Interrupting Capacity Approvals*
Thermal circuit breakers 15 to 30 Amps : 8 to 50 seconds Per SAE J553, 600A 9115-5 meets
30VDC, 15 to 30 Amps CID A-A-55571/01
Sealed assemblies, available in manual 9115-6 meets
and automatic reset options CID A-A-55571/02
Ignition protected SAE J1171 UL Listed (E 36869)
CCC certified
14 Klixon - Circuit Breakers & Protectors http://www.sensata.com/
GFCI & ELCI
Linegard PGFM Sensing Module
General Description Ground Trip Current Interrupting Capacity Approvals*
Ground fault sensing module designed to 4 to 6 mA As per ratings of the UL 943, Class A
operate in tandem with the Airpax LEL series Airpax LEL series or
circuit breaker with a shunt voltage trip and Trip Time, Combined Assembly circuit breaker UL 1053 Compliant
auxiliary switch and up to 3 poles max 25 mS
Manufactured by North Shore Safety, Ltd.,
a leader in innovative safety products Operating Voltage Rating
Automatic and manual reset configurations 120 VAC or 240 VAC, 50/60 Hz
Power and fault status indicators
Double insulated user interface Let-Go Voltage
60% of supply voltage
Linegard 40, 50 & 60 Amp PGFI Portable Series
General Description Rated Current Packaging Approvals*
40, 50 & 60 amp in-line Equipment Leakage 40, 50 or 60 amps NEMA 4X wet location UL 1053 compliant
Circuit Interrupter (ELCI) rated
Manufactured by North Shore Safety, Ltd., Rated Voltage
a leader in innovative safety products 120 VAC, 240 VAC, 208 VAC, 277 VAC,
Automatic and manual reset key switch 120/240 VAC, 3 240 VAC, 3 208 VAC,
selector 3 277 VAC, 3 480 VAC, 3 600 VAC
Fault threshold key switch selector
Available with locking connectors / plugs or Operating Voltage Range
flying leads 85% to 110% of rating
Electro-magnetically latched contacts
Ground Trip Current Threshold
Key switch selectable
6 mA, 10mA, and 30mA
Linegard 40, 50 & 60 Amp PGFS Permanent Series
General Description Rated Current Packaging Approvals*
40, 50 & 60 amp splice-in Equipment Leakage 40, 50 or 60 amps NEMA 4X wet location UL 1053 compliant
Circuit Interrupter (ELCI) rated
Manufactured by North Shore Safety, Ltd., Rated Voltage
a leader in innovative safety products 120 VAC, 240 VAC, 208 VAC, 277 VAC,
Automatic / manual reset key switch 120/240 VAC, 3 240 VAC, 3 208 VAC,
Fault trip level key switch 3 277 VAC, 3 480 VAC, 3 600 VAC
Keyed power switch
Dual indication lights displaying power and Operating Voltage Range
fault status 85% to 110% of rating
Grounded and open neutral protected
Electro-magnetically latched contacts Fault Trip Level Current
6 mA, 10 mA and 30mA
Linegard 30 Amp PGFS Permanent Series
General Description Rated Current Packaging Approvals*
30 amp splice-in Ground Fault Circuit Up to 30 amps NEMA 4X wet location cULus 943, Class A
Interrupter (GFCI) rated cCSAus certified to
Manufactured by North Shore Safety, Ltd., Rated Voltage CSA-C22.2 No. 144
a leader in innovative safety products 120 VAC, 208 VAC, 240 VAC, 120/240 VAC
Automatic and manual reset configurations 277 VAC (non-UL)
Fault output options available
Grounded and open neutral protected Operating Voltage Range
Electro-magnetically latched contacts 85% to 110% of rating
Ground Trip Current
4 to 6 mA
Linegard 30 Amp PGFS Multi-Phase Permanent Series
General Description Rated Current Packaging Approvals*
30 amp multi-phase splice-in Ground Fault Up to 30 amps NEMA 4X wet location cULus 943, Class A
Circuit Interrupter (GFCI) rated cCSAus certified to
Manufactured by North Shore Safety, Ltd., Rated Voltage CSA-C22.2 No. 144
a leader in innovative safety products 120/240 VAC dual voltage,
Automatic and manual reset configurations 120/208 VAC 3, 240 VAC 3,
Dual indication lights displaying power and 208 VAC 3, 277 VAC 3 (non-UL or CSA)
fault status
Grounded and open neutral protected Operating Voltage Range
Electro-magnetically latched contacts 85% to 110% of rating
Ground Trip Current
4 to 6 mA
http://www.sensata.com/ North Shore Safety - GFCI & ELCI 15
GFCI & ELCI
Linegard 15 Amp PGFP Plug Series
General Description Rated Current Packaging Approvals*
15 amp plug cordset Ground Fault Circuit Up to 15 amps at 120 VAC, 50/60 Hz NEMA 3R rated cULus 943, Class A
Interrupter (GFCI) or
Manufactured by North Shore Safety, Ltd., Ground Trip Current UL recognized
a leader in innovative safety products 4 to 6 mA
Automatic and manual reset configurations
Available as a field wireable plug or with Insulation Voltage
attached cords and outlets 1500 VRMS - 1 minute
Plug assembly with power single or tri-tap
outlet Endurance Operations
Electro-magnetically latched contacts 3000 operations
Linegard 15 Amp PGFI In-line Series
General Description Rated Current Packaging Approvals*
15 amp in-line cordset Ground Fault Circuit Up to 15 amps at 120 VAC, 50/60 Hz NEMA 3R rated cULus 943, Class A
Interrupter (GFCI) cCSAus certified to
Manufactured by North Shore Safety, Ltd., Ground Trip Current CSA-C22.2 No. 144
a leader in innovative safety products 4 to 6 mA or
Automatic and manual reset configurations UL recognized
Available as a field wireable plug or with Insulation Voltage
attached cords and outlets 1500 VRMS - 1 minute
Plug assembly with power single or tri-tap outlet
Electro-magnetically latched contacts Endurance Operations
3000 operations
Linegard 20 Amp PGFI Portable Series
General Description Rated Current Packaging Approvals*
20 amp in-line cordset Ground Fault Circuit Up to 20 amps NEMA 4X wet location cULus 943, Class A
Interrupter (GFCI) rated cCSAus certified to
Manufactured by North Shore Safety, Ltd., Rated Voltage CSA-C22.2 No. 144
a leader in innovative safety products 120 VAC, 208 VAC, 240 VAC, 277 VAC
Automatic and manual reset configurations
Available with locking connectors / plugs or Operating Voltage Range
flying leads 85% to 110% of rating
Electro-magnetically latched contacts
Ground Trip Current
4 to 6 mA
Linegard 30 Amp PGFI Portable Series
General Description Rated Current Packaging Approvals*
30 amp in-line cordset Ground Fault Circuit Up to 30 amps NEMA 4X and 6P wet cULus 943, Class A
Interrupter (GFCI) location rated cCSAus certified to
Manufactured by North Shore Safety, Ltd., Rated Voltage CSA-C22.2 No. 144
a leader in innovative safety products 120 VAC, 208 VAC, 240 VAC, 277 VAC
Automatic and manual reset configurations
Available with locking connectors / plugs or Operating Voltage Range
flying leads 85% to 110% of rating
Electro-magnetically latched contacts
Ground Trip Current
4 to 6 mA
Linegard 30 Amp PGFI Multi-Phase Portable Series
General Description Rated Current Packaging Approvals*
30 amp multi-phase cordset Ground Fault Up to 30 amps NEMA 4X and 6P wet cULus 943, Class A
Circuit Interrupter (GFCI) location rated cCSAus certified to
Manufactured by North Shore Safety, Ltd., Rated Voltage CSA-C22.2 No. 144
a leader in innovative safety products 120/240 VAC dual voltage,
Automatic and manual reset configurations 120/208 VAC 3, 240 VAC 3,
Dual indication lights displaying power and 208 VAC 3, 277 VAC 3 (non-UL or CSA)
fault status
Grounded and open neutral protected Operating Voltage Range
Electro-magnetically latched contacts 85% to 110% of rating
Ground Trip Current
4 to 6 mA
16 North Shore Safety - GFCI & ELCI http://www.sensata.com/
DC TO AC POWER INVERTERS
MILITARY
General Description List of Standard & Add-On Options
DIMENSIONS inverters provide DC to AC power conversion for many of todays Cage code: 0CCB0
military systems:
Configuration limitations vary for each product, but available options
Troop transport Mobile weaponry systems can include:
Light & heavy armor vehicles Mobile radar & communications
Operating temperature up to -37C to 70C (-35F to 158F)
With the ever-growing demand for remote on-demand AC power, we provide Ventless construction for moisture and dust resistance
multiple wave form outputs to satisfy your customers AC power needs: Thermally-controlled cooling fan
Heavy duty conformal coating on circuit boards
Single Phase Pure Sine Wave, <5% THD typical NATO input receptacles
Single Phase Quasi Sine Wave, with wave form stabilizer NEMA connector distribution box with circuit breakers
Three Phase Quasi Sine Wave, single pulse per phase, pulse-width modulated Water fording capability
Outdoor plug covers
DC input reverse polarity protection
Electrical Specifications Ground fault circuit interrupt (GFCI) outlet protection
Ground fault circuit interrupt (GFCI) hard wire output protection
Depending on your AC energy requirements, there are many DIMENSIONS Enclosed AC and DC cable connections
inverters available to meet your power needs, including ratings of: Integrated ON / OFF switch
Remote ON / OFF switch hookup
Input Voltage = 24 Volts DC Battery voltage indicator with push-to-reset
Output Power = from 300 to 12,000 Watts Continous Output circuit breakers
Branch breakers
Output Current = up to 32 Amps 120 VAC, 42 Amps 240 VAC
Automatic electronic short circuit / overload protection
Peak Output = up to 250 Amps AC Automatic high temperature shutdown
Output Rating = up to 10.0 horse power Automatic low battery shutdown with in-rush delay
Input Current = up to 600 Amps DC Dual output voltage, 120/240 VAC
LED indication of inverter power, low input voltage, overload and
GSA Products high temperature
Elapsed time hour meter
The following DIMENSIONS inverters are GSA registered:
DIMENSIONS MIL-24/300NQ
NSN # 6130-01-453-0020
DIMENSIONS MIL-24/2600Q
NSN # 6130-01-452-0577
Military PN # 0CCB0405570
DIMENSIONS MIL-24/3200DQ
NSN # 6130-01-439-1789
Military PN # 0CCB0DUI24/32DQ
DIMENSIONS MIL-24/6000H-3PH
NSN # 6130-01-492-3067
Military PN # 11B258001
DIMENSIONS MIL-24/12000H-3PH
Dimensions - DC to AC Power Inverters 17
DC TO AC POWER INVERTERS
MOBILE AC POWER
General Description List of Standard & Add-On Options
DIMENSIONS inverters provide DC to AC power conversion for many of todays Configuration limitations vary for each product, but available options
mobile markets: can include:
Utility & Work Truck Marine UL & CUL listed
Emergency Vehicles Auto Glass Replacement Vehicles Quasi wave form stabilizer
Recreational Vehichles (RVs) Construction Equipment Quasi wave form smoothing filter
Thermally-controlled cooling fan
With the ever-growing demand for remote on-demand AC power, we provide Ground fault circuit interrupt (GFCI) outlet protection
multiple wave form outputs to satisfy your customers AC power needs: Ground fault circuit interrupt (GFCI) hard wire output protection
Enclosed AC and DC cable connections with strain relief
Single Phase Pure Sine Wave, <5% THD typical Integrated ON / OFF switch
Single Phase Quasi Sine Wave, with wave form stabilizer Remote ON / OFF switch hookup
Battery voltage indicator with push-to-test
Three Phase Quasi Sine Wave, single pulse per phase, pulse-width modulated
Output circuit breakers
Branch breakers
Electrical Specifications
Automatic electronic short circuit / overload protection
Automatic high temperature shutdown
Depending on your AC energy requirements, there are many DIMENSIONS
Automatic low battery shutdown with in-rush delay
inverters available to meet your power needs, with ratings of:
Automatic 120/240 VAC input voltage sensing
Automatic battery conditioning
Input Voltage = 12 or 24 Volts DC Transfer relays (including fail-safe transfer to shore power)
Output Power = from 250 to 12,000 Watts Continous Battery chargers (including automatic safety start and power share)
Output Current = up to 33 Amps AC Dual output voltage, 120/240 VAC
Peak Output = up to 140 Amps AC Remote LCD and LED display / control panels
Motor-starting capability
Output Rating = up to 10.0 horse power
Ventless construction for moisture and dust resistance
Input Current = up to 600 Amps DC Elapsed time hour meter
Battery Charger Output = up to 140 Amps DC, 28 Amps AC One-wire ground start
INTERNATIONAL STANDBY POWER SYSTEMS (EXPORT ONLY)
General Description List of Standard & Add-On Options
Depending on your AC energy requirements, there are many DIMENSIONS Configuration limitations vary for each product, but available options
inverters available to meet your power needs: can include:
Single Phase Pure Sine Wave, <5% THD typical Thermally-controlled cooling fan
Single Phase Quasi Sine Wave, with wave form stabilizer AC hard wire output
Enclosed AC and DC cable connections
Electrical Specifications Remote ON / OFF switch hookup
Digital signal controller for improved performance
Whether its 120VAQC 60Hz or 230VAC 50Hz output, there is a DIMENSIONS Output circuit breakers
inverter available to meet your power needs, with ratings including: Automatic electronic short circuit / overload protection
Automatic high temperature shutdown
Input Voltage = 12 or 24 Volts DC Automatic low battery shutdown with in-rush delay
Battery chargers (temperature compensated)
Output Power = from 600 to 3,600 Watts Continous
LED status display and battery voltage indicator
Output Current = up to 30 Amps AC
Peak Output = up to 90 Amps AC
Input Current = up to 180 Amps DC
18 Dimensions - DC to AC Power Inverters http://www.sensata.com/
DC TO AC POWER INVERTERS
TRAFFIC SIGNAL BATTERY BACKUP SYSTEMS
General Description List of Standard & Add-On Options
Dimensions Battery Backup Systems are designed to provide reliable power Configuration limitations vary for each product, but available
to your traffic signal intersections. Through thunderstorms, blown transformers, options can include:
downed power lines or other interruptions, our Battery Backup Systems will keep
your LED intersections running for hours. LCD Display, easy to read, large 4 line backlit display
Scrolling banner which lists relay status, alarms and faults
Electrical Specifications Display shows input/output values including battery % charge
Keypad for local programming
Whether its 170,2070, NEMA or external cabinet mount, there is a DIMENSIONS Web browser interface
inverter available to meet your requirements, with ratings that can include: Buck / boost for line interactive / automatic voltage regulation operation
Time of day program
Input Voltage = 24 or 48 Volts DC Adjustable transfer points with normal and generator settings
Six fully programmable dry relay contacts w/ low battery and timer
Output Power = from 1,100 to 1,700 Watts Continous
Backup event and run time meters with reset
Output Current = up to 14 Amps AC Buck / boost event and run time meters with reset
Peak Output = up to 53 Amps AC Event log of events, up to 200 events with export capability
Input Current = up to 60 Amps DC Ethernet (IP is user configurable) and RS-232 communications
Pure Sine Wave, <3%THD, 60Hz 0.05%
3 stage, power factor corrected, fast rate charger
Temperature compensated charging
Transient voltage protection compliant with IEEE 587/ANSI C.62.41
Thermally controlled cooling fan
Automatic low battery shutdown
Completely connectorized system
Caltrans approved version available
INDUSTRIAL (HIGH VOLTAGE)
General Description List of Standard & Add-On Options
For industrial locations, where high voltage is a must, DIMENSIONS inverters Configuration limitations vary for each product, but available
come in a single phase quasi sine wave form, capable of accepting up to 300VDC options can include:
input. DIMENSIONS also offers 250VDC input UPS and transient voltage surge
suppressors. Quasi-sine wave with waveform stabilizer
Thermally-controlled cooling fan
Electrical Specifications Ground fault circuit interrupt (GFCI) outlet protection
Enclosed AC and DC cable connections
When high voltage DC input is needed, there is a DIMENSIONS inverter NEMA type 12 enclosure
available to meet your requirements, with ratings that can include: Remote ON / OFF switch hookup
Output circuit breakers
Input Voltage = 32, 36, 48, 64, 125, 250 or 300 Volts DC Automatic electronic short circuit / overload protection
Output Power = from 500 to 10,000 Watts Continous Automatic high temperature shutdown
Automatic low battery shutdown with in-rush delay
Output Current = up to 83 Amps AC Transfer relay
Peak Output = up to 240 Amps AC
Output Rating = up to 5.0 horse power
Input Current = up to 300 Amps DC
http://www.sensata.com/ Dimensions - DC to AC Power Inverters 19
Sensata Technologies is one of the worlds leading suppliers of sensing, electrical protection and control solutions across a
broad array of industries and applications in the automotive, appliance, aircraft, industrial, military, heavy vehicle, heating,
ventilation and air conditioning, telecommunications, recreational vehicles, marine, medical, information processing,
electronic power supply, power generation, construction, agricultural, and alternative energy markets.
For more information, please visit our web site at www.sensata.com
AIRPAX 6600 & 6700 bimetal thermostats Sensata Technologies
AIRPAX hydraulic magnetic circuit breakers & protectors Power Protection
LINEGARD GFCI & ELCI 807 Woods Road
AIRPAX power switches Cambridge, MD 21613 USA
AIRPAX modular distribution systems Tel: 410.228.4600 (Main)
Fax: 410.228.3456
E-mail: cmbinfoppp@sensata.com
http://airpax.sensata.com
KLIXON thermal & aircraft circuit breakers Sensata Technologies
KLIXON bimetal thermostats Precision Products
AIRPAX bimetal thermostats (not 6600 & 6700) 529 Pleasant Street, MS 1-38
KLIXON airflow sensors Attleboro, MA 02703 USA
Tel: 508.236.3800
Fax: 508.236.2266
E-mail: klixonmail@list.sensata.com
http://www.klixon.com
DIMENSIONS DC to AC power inverters Sensata Technologies
DIMENSIONS battery chargers Power Protection
4467 White Bear Parkway
St. Paul, MN 55110 USA
Tel: 800.553.6418 (Toll-free)
Tel: 651.653.7000 (Main)
Fax: 651.653.7600
E-mail: inverterinfo@sensata.com
http://dimensions.sensata.com
2012 Sensata Technologies, Inc. All rights reserved worldwide. Printed in USA, revised April 2012.
Doc # 245-500-5003
Important Notice: Sensata Technologies reserves the right to make changes to, or to discontinue, any product
or service identified in this publication without notice. Before placing orders, users should obtain the latest
version of the relevant information to verify that the information being relied upon is current.
Sensata Technologies assumes no responsibility for customers product designs or applications. Users must
determine the suitability of the Sensata device described in this publication for their application, including the
level of reliability required. Many factors beyond Sensatas control can affect the use and performance of a
Sensata product in a particular application, including the conditions under which the product is used and the
time and environmental conditions in which the product is expected to perform. As these factors are uniquely
within the users knowledge and control, it is essential that the user evaluate the Sensata product to determine
whether it is t for a particular purpose and suitable for the users application. Sensata Technologies products
are sold subject to Sensatas Terms and Conditions of Sale which can be found at: www.sensata.com/terms.htm