Indicador NT 200a
Indicador NT 200a
NT-200 Series
 NT-200
  OPERATING MANUAL
         -1-
                     Table of Contents
0. Precaution ------------------ 3
1. Introduction ------------------ 4
3. Specification ------------------ 6
4. Dimensions ------------------ 7
7. Installation ------------------ 12
                            -2-
 0. Precaution
Our Dealers:    CAS feels that each of its valued customers should get the
   best service available. Whether it’s the initial installation of our product,
   maintenance/repair work, or simply answering questions about our
   products, CAS Corporation and all of its Authorized Dealers are highly
   trained to assist you with any need regarding CAS products.
                                      -3-
1. Introduction
                                -4-
2. Features & Main Function
Features
  Appropriate for Weight and Measurement System
  Easy Operation
  Full Digital Calibration
  Weight Back-Up [ Weight Memory at Sudden Power Failure ]
  4 Multi-Point Calibration
  Command Mode Function (Control by PC – Request and Set the Data)
  6 Wires / 4 Wires Load Cell (Select the Dip Switch inside)
  Dual Range
  Kg/lb Conversion & kg/lb Calibration
  Lock Function of Front Key
  User Message Print Function
                                      -5-
   Output the signal of Hi & Low limit, Zero, OK with serial comm.
   Count, Limit, Accumulation and Percent Function
   Set Point ( 20 of (tare     ), (Hi-limit, Low-limit, Count unit each   )
   Preset Tare
   Gravity Compensation
Main Function
   Various Printer Connection [ Roll DEP & Label DLP Printer Support ]
   Users can Set the Desirous Max. weight and a Division Freely
   Independent Zero Calibration
   Self Hard Ware Test
3. Specification
                                         -6-
                                 1 / 10,000 (Non NTEP, OIML, KS)
Digital Part
                                 NT-200A, NT-200S         LED (6 digit)
 Display
                                 NT-201A, NT-201S         LCD (6 digit + Sign)
                                 NT-200A, NT-200S         25 mm (Height)
 Character Size
                                 NT-201A, NT-201S         24 mm (height)
 Display below zero              "-" minus sign
 Lamp                            ZERO, TARE, GROSS, NET, STABLE, HOLD,
                                 UNIT(kg, lb)
 AC Adapter                      AC 230 V (DC 9V, 600mA)
 Operating Temperature           -10℃ ~ 40℃
 Product Size                    96mm(H) x 200mm(L) x 52mm(W)
 Product Weight                  Approx. 0.5Kg
 Communication Part
 Standard                        COM1 (RS-232 Printer & PC Interface )
 Option                          RTC (Real Time Clock)
                                 COM2 (RS-422 Multi Drop Interface)
* You can use COM2 for connecting printer (RS-232)
 4. Dimension
NT-200A, NT-201A
                                      -7-
NT-200S, NT-201S
5. Front Panel
                   -8-
NT-201A
    Display Lamp
        STABLE         Measured Weight is stable
                            -9-
NT-200A
    Display Lamp
STABLE          Measured Weight is stable
ZERO            Current Weight is 0 kg
TARE            Used to weigh an item by using the container
    Key Board
Used to enter setting value in TEST, CAL, and SET mode instead of
Numeric keys
                                  - 10 -
◀          Moves one digit to left
    ZERO KEY
    Used to remove small variations in the indicator’s zero
    If pressed for 2 sec,   you can go to SYSTEM Mode
    TARE KEY
    Used to weigh an item by using the container
    Current weight is memorized as tare weight
    If pressed in unload condition, tare setting is released
    If pressed for 2 sec,   you can go to KeyTare Mode
    When you know the tare weight, you can enter the tare weight
If pressed for 2 sec, you can "CodE=Z lim=t". Then you can
    PRINT KEY
    If you print, current weight is added to total weight
    You can print out the sub total weight with ZERO key and
    total sum weight with TARE key
    After the sub total weight is printed out, it is set to zero(0)
                               - 11 -
       If pressed for 2 sec, you can see "dEvi = Z   Set = t".
You can go to DEVIDE with ZERO, SET Mode with TARE key
       UNIT KEY
       You can change the unit of weight ( kg/lb ) (USA Version)
       All functions are used with the unit of weight is selected
       in weight calibration in CAL MODE.
       If you press UNIT key for 2 sec, power is turned off
 6. Rear Panel
NT-200A, NT-201A
NT-200S, NT-201S
                                - 12 -
.CAL S/W           Calibration Switch Bolt
.POWER             Port for Power
.LOAD CELL         Port for connecting Load Cell
.RS-232C           Serial Interface COM1, COM2 Port
                   [connect to PC, Printer]
.F/G               Ground Terminal [ Frame Ground ]
                   If it is not connected, it may cause trouble
7. lnstallation
                                    - 13 -
Note: Wire color can be different depending on the manufacturer or
       Load cell’s model
4 (SEN-) BLACK
8. Test Mode
                                     - 14 -
 In Test mode, Back-light is On.
TEST 1
KEY TEST
   KEY       FUNCTION        DISPLAY                    DESCRIPTION
  UNIT      Go to TEST2      tESt 1       TEST 1 Condition
            Testing               1       Press any key to test then the
OTHERS
            Key Codes                     Code of that key is shown below
KEY
CODE 0 1 2 4 8 Go to TEST2
TEST 2
                                       - 15 -
 A/D Conversion TEST (Load Cell Test)
    KEY         FUNCTION       DISPLAY                      DESCRIPTION
   UNIT       Go to TEST3        tESt 2       TEST 2 Condition
                                              TEST 2 is performed automatically
                                 24750
                                              This value can be changed
Note 1. Check the numeric by loading and unloading a weight.
If the numeric is not changed or it is o, check the connection of the load cell.
TEST 3
 RS - 232 TEST with Computer (RS - 232C)
    KEY         FUNCTION       DISPLAY                      DESCRIPTION
   ZERO       Transmit ‘0
   TARE       Transmit ‘1        tESt 3       TEST 3 Condition
 NET/GRS      Transmit ‘2
  PRINT       Transmit ‘4        -----        Waiting for Transmission & reception
  ENTER       Transmit ‘8’     0 ----- 1      Receive : 1     Transmit : 0
   UNIT       Go to TEST4      2 ----- 1      Receive : 1     Transmit : 2
Note 1. Before testing, connect RS-232C of PC to COM1 port of Indicator.
Note 2. If you send ASCII code 0 ~ 9 in PC keyboard, Indicator receives this data.
          If you press "1(ZERO key) " of indicator, you can check it in PC.
                                           - 16 -
TEST 4
 RS - 422/485 TEST with Computer (RS - 422/485)
    KEY         FUNCTION      DISPLAY                   DESCRIPTION
   ZERO       Transmit ‘0’
   TARE       Transmit ‘1’     tESt 4     TEST 4 Condition
 NET/GRS      Transmit ‘2’
  PRINT       Transmit ‘4’      -----     Waiting for Transmission & reception
  ENTER       Transmit ‘8’    0 ----- 1   Receive : 1       Transmit : 0
   UNIT       Go to TEST5     2 ----- 1   Receive : 1       Transmit : 2
Note 1. Before testing, connect RS-422/485 of PC to COM2 port of Indicator and
          run the communication program of PC.
Note 2. Before testing, connect COM2 port of Indicator.
Note 3. If you send ASCII code 0 ~ 9, Indicator receives this data.
          If you press "1(ZERO key) " of indicator, you can check it in connected
          device.
TEST 5
 PRINTER TEST
    KEY         FUNCTION       DISPLAY                  DESCRIPTION
              Go to
   UNIT
              Normal Mode       tESt 5
                                             TEST 5 Condition
              Testing the
  ENTER
              Printer
Note 1. You should set the use of printer and printer in Device mode.
Note 2. If printer connection and setting is done successfully,
          the display shows "good" and if not, the displays shows error message.
Note 3. Test Output Form of Printer is as follows.
          And see " TEST OK " in the Hyper Terminal also.
TEST OK
                                          - 17 -
9. System Mode
you can see the "SyS" on the display after showing "on". And then
you can move to any mode where you want to go using the G/N key.
SYSTEM MODE
     MODE                [G/N] key     DISPLAY [ENTER] key      ACTION
Count MODE      Ⅱ) ↓
               (Ⅱ                      CoUnt      END        Count   Mode
                         Circulation
              Ⅲ)
Percent MODE (Ⅲ      ↓ Key             PEr        END        Percent Mode
Accumulation
                                                             Accumulation
                     ↓                 ACC        END
MODE            Ⅳ)
               (Ⅳ                                            Mode
                         ENTER
                                       WEiGht     END        Weighing Mode
WEIGHT MODE(ⅠⅠ)
Weighing Mode
                                       - 18 -
           Ⅱ)
COUNT MODE(Ⅱ
Counting Mode
( ) Press the [TARE] key long to set the Count Mode in detail
     DISPLAY           KEY                          DESCRIPTION
                                Input the weight of unit with sample,
         on          ZERO       and go to count weighing mode
                                       - 19 -
                                Input the weight of sample with key
WEiGht
                                For example, set the 0.5kg to count ‘1’
0.500 kg
                    ENTER       After saving, go to initial display of count mode
Err 08                          If the weight of sample is over the maximum
                                Capacity, err 08 is displayed and return
                    ENTER       It is displayed and then go to counter mode
             Ⅲ)
PERCENT MODE(Ⅲ
Percent Mode
( ) Press the [TARE] key long to set the Percent Mode in detail
     DISPLAY          KEY                           DESCRIPTION
                                After weighing the weight of 100%,
         on         ZERO
                                go to the percent weighing mode
                                      - 20 -
    DISPLAY         KEY                      DESCRIPTION
                           Input the weight of sample with key.
WEiGht                     Set the 20.00kg to 100%
20.00 kg                   After saving,
                  ENTER
                           go to initial display of percent mode
Err 08                     If the weight of sample is over the maximum
                           Capacity, err 08 is displayed and return
                  ENTER    It is displayed and then go to percent mode
                                  - 21 -
                  Ⅳ)
ACCUMULATION MODE(Ⅳ
Accumulation Mode
                                     - 22 -
                               Times of Adding and Total weight are
                   Short       displayed for 5 seconds ( C = 003, 20.5kg)
ENTER
                               If you press [ZERO] key, All data is cleared
                   Long        Go to the Function mode
UNIT               Long        Power Off
Multi-point
                                    - 23 -
                                      rEAdY
                                  CALMod
   UNIT                : 0 : kg         1 : lb
   CAL 0               : Multi Calibration Setting
   CAL 1               : Maximum Capacity Setting
   CAL 2               : Minimum Division Setting
   CAL 3               : Zero Calibration
   CAL 4/6/8/10        : A Weight Setting (First~Fourth)
   CAL 5/7/9/11        : Span Calibration (First~Fourth)
CAL 0
MULTI - CALIBRATION SETTING
                                       - 24 -
    KEY      FUNCTION        DISPLAY                    DESCRIPTION
                             CAL 0        CAL 0 Condition
                              P=1         1 Point Multi-Calibration
             Increase or
                              P=2         2 Point Multi-Calibration
             decrease
                              P=3         3 Point Multi-Calibration
             set   value
                              P=4         4 Point Multi-Calibration
  ENTER
             Next Menu                          Save the value and go to CAL 1
   UNIT
1 (OFF)   : You can calibrate indicator with zero calibration and span calibration.
2 ~ 4 (ON): You can set the weight what you want in the zero calibration and
            the setting weight (CAL 4) and span calibration (CAL 5)
CAL 1
 MAXIMUM CAPACITY SETTING
 Available Setting Range : 1kg ~ 999,999kg
    KEY      FUNCTION        DISPLAY                    DESCRIPTION
                             CAL 1        CAL 1 Condition
             Increase or
             decrease         5000        5000kg
             set   value
             Move one
             digit to left   10000        10000kg
CAL 2
 MINIMUM DIVISION SETTING
 Available Setting Range : 0.001kg ~ 100kg
    KEY      FUNCTION        DISPLAY                    DESCRIPTION
                             CAL 2        CAL 2 Condition
                                       - 25 -
             Increase or          1           1kg
             decrease
             set   value        0.01          0.01kg
  ENTER      Next Menu                        Save the value and go to CAL 3
Note 1. The minimum division means one division
Note 2. External resolution should be within 1/20,000.
          (External resolution= a division/maximum weight).
CAL 3
 ZERO CALIBRATION
    KEY       FUNCTION       DISPLAY                      DESCRIPTION
                              CAL 3           CAL 3 Condition
                                              Remove weight from the platter
                              ULoAd
                                              and Press UNIT KEY
                               ---------      Performing Zero Calibration
                               Good           Zero Calibration is finished
  ENTER      Next Menu                        Save the value and go to CAL 4
Note 1. If zero calibration is finished successfully, the display shows “Good" and
        then you will go to CAL 4 automatically.
CAL 4
 WEIGHT SETTING
 Available Setting Range : 1kg ~ 999,999kg
    KEY       FUNCTION       DISPLAY                      DESCRIPTION
                              CAL 4           CAL 4 Condition
             Increase or
             decrease          1000           1000kg
             set   value
             Move one                         2000kg
                                           - 26 -
              digit to left    2000
CAL 5
 SPAN CALIBRATION
    KEY       FUNCTION        DISPLAY                     DESCRIPTION
                                              Put the weight that is set in CAL 4
                              CAL 5
                                              and then press the UNIT KEY
                                              Repeat this step according to multi
                              LoAd1
                                              calibration setting
                               ---------      Performing Span Calibration
                               Good           Span calibration is finished
                               Save           Remove the weight,
                                              press ENTER KEY Move to the
                                              initial CALMOd
   For example, if you set CAL 0 to 4, perform CAL 4, CAL 5, CAL 6 , CAL 7, CAL 8,
   CAL 9, CAL10, and CAL11.
                                           - 27 -
※ Example
Max. capacity: 5000 kg, Min. division: 1 kg, Multi calibration(CAL 0) : 4 point
A weight: 2000 kg 1EA, 1000 kg 2EA, 500 kg 1EA
CAL 0 : 4            CAL 1 : 5000         CAL 2 : 1        CAL 3 : Zero calibration
CAL 4 : 2000         CAL 5 : LOAD1        CAL 6 : 1000     CAL 7 : LOAD2
CAL 8 : 1000         CAL 9 : LOAD3        CAL 10 : 500     CAL 11 : LOAD4
 GRAVITY COMPENSATION
    KEY        FUNCTION         DISPLAY                      DESCRIPTION
                                G-CAL           Gravity Compensation
               Increase or
                                Gr CAL          Gravity of calibration place
               decrease
                                98000           Set the value
               set    value
  ENTER        Next Menu                        Save and go to Gr Set
               Move one
                                 Gr Set         Gravity of using place
               digit to left
                                 98000          Set the value
                                             - 28 -
Bangkok           9.783 ㎨   Lisbon             9.801 ㎨      San Francisco     9.800 ㎨
Birmingham        9.813 ㎨   London             9.812 ㎨      Singapore         9.781 ㎨
Brussels          9.811 ㎨   Los Angeles        9.796 ㎨      Stockholm         9.818 ㎨
Buenos Aires      9.797 ㎨   Madrid             9.800 ㎨      Sydney            9.797 ㎨
Calcutta          9.788 ㎨   Manila             9.784 ㎨      Tainan            9.788 ㎨
Chicago           9.803 ㎨   Melbourne          9.800 ㎨      Taipei            9.790 ㎨
Copenhagen        9.815 ㎨   Mexico City        9.779 ㎨      Tokyo             9.798 ㎨
Cyprus            9.797 ㎨   Milan              9.806 ㎨      Vancouver BC      9.809 ㎨
Djakarta          9.781 ㎨   New York           9.802 ㎨      Washington DC     9.801 ㎨
Frankfurt         9.810 ㎨   Oslo               9.819 ㎨      Wellington        9.803 ㎨
Glasgow           9.816 ㎨   Ottawa             9.806 ㎨      Zurich            9.807 ㎨
STABLE CONDITION
  KEY       FUNCTION        DISPLAY     VAL.                  DESCRIPTION
            Increase or                   11       21: Judge if the weight is changed
            decrease                                   Within 1 division for 1 sec
            set   value     S02 =         ~        45: Judge if the weight is changed
                                                       Within 2 division for 5 sec
ENTER       Save &
                                          99       90: Judrge if the weight is changed
 UNIT       Go to Next
                                                       Within 4.5 division for 9 sec
                                          - 29 -
            decrease                                          Within 1 division for 1 sec
                                              :
            set    value      S03 =                       45: Judge if the weight is changed
                                             99               Within 2 division for 5 sec
 ENTER      Go to initial
                                                          90: Judrge if the weight is changed
  UNIT      CALMod
                                                              Within 4.5 division for 9 sec
   Sealing Method
After calibration, you have to seal as follows.
  1. Fasten the CAL Switch Bolt.
  2. Connect the sealing wire as figure.
  3. Press the sealing wax as figure.
                                             - 30 -
11. Function Mode
 How to Go to Set Mode
 If you press the [ENTER] key during 3 seconds in normal mode,
 you can go to Function Mode after displaying
              "on"    and " dEUI=Z "         " SEt=t "
                                  - 31 -
 F04    Back-light
WEIGHT BACKUP
 KEY     FUNCTION       DISPLAY VAL.                   DESCRIPTION
                         SET
        Select 0 or 1              0       Not use weight backup
        Save &            F01
ENTER                              1       Use weight backup (Zero, Tare….)
        Go to F02
 UNIT   Save & Exit                        Save & go to Normal Mode
                                  - 32 -
  UNIT      Save & Exit                                 Save & go to Normal Mode
 BACK-LIGHT
   KEY       FUNCTION        DISPLAY VAL.                            DESCRIPTION
                                                0       Always off
            Select 0 ~ 3                                If you press any key, back-light is
                                                1
                                   F04                  on for 5 seconds
                                                        If there is a weight change, back-
            Save &                              2
 ENTER                                                  light is on for 5 seconds
            Go to F05
                                                3       Always on
  UNIT      Save & Exit                                 Save & go to Normal Mode
[ CHECKER MODE]
   Weight
                     (Low Limit)         (High Limit)                                   OUT
Comm
                0 kg          50 kg              100 kg                                 PUT
Signal
                                                                                          1
  ZERO                                                                                    0
                                                                                          1
  LOW                                                                                     0
                                               - 33 -
                                                                                          1
  HIGH                                                                                    0
                                                                                          1
   OK                                                                                     0
Note 1.     All outputs are generated regardless of stable state.
[ LIMIT MODE]
   Weight
                     (Low Limit)          (High Limit)                                   OUT
Comm
                  0 kg            50 kg           100 kg                                 PUT
Signal
                                                                                          1
  ZERO
                                                                                          0
                                                                                          1
  LOW
                                                                                          0
                                                                                          1
  HIGH
                                                                                          0
                                                                                          1
   OK                                                                                     0
Note 1.     OK signal is output when the state is stable only.
 KEY LOCK
  KEY         FUNCTION            DISPLAY VAL.                      DESCRIPTION
                                                - 34 -
          Select 0 or 1                 0        Not change the key lock
          Save &              F08
ENTER                                   1        Set the key lock item (L01 ~ L10)
          Go to F09
 F08 = 1 (Key Lock)
                              L01                Zero Key
                              L02                Tare Key
                              L03                Gross Key
                              L04                Print Key
          0 : Not             L05                Enter Key
             lock the key     L06                Unit Key
          1 : Lock            L07                Zero Sub Key
                                        0
             that key         L08                Tare Sub Key
          Sub :               L09                Gross Sub Key
                                        or
             Press for        L10
             3 seconds
                                        1
          Select 0 ~ 1
          Save & Next                            Print Sub Key
ENTER
 UNIT     Save & Exit                            Save & go to Normal Mode
Note 1. Although key lock is set after setting the value of F08 to 1,
          The value of F08(1) is not saved. Always the value of F08 is started to 0.
          Same to F09 and F10.
                                        - 35 -
                             Good      4 digits
                            PASS - 0 Not set the Enter key password
          Select 0 or 1
                            PASS - 1 Set the Enter key password
 UNIT     Save & Exit                  Save & go to Normal Mode
Note 1. If the password is not correct, the message of "AgAIn" is displayed.
         If you failed three times continuously, the message of "Fail" is displayed
         and exit this mode automatically.
DEVICE Mode
                                        - 36 -
 D07    Printer type                       D14      Set the current clock
DEVICE ID
 KEY    FUNCTION       DISPLAY   VAL.                  DESCRIPTION
        Increase or                        01: ID=0,   99: ID=99
        decrease                 00        If you use a system, you can iden-
        set   value     d01      ~         tify each indicator by this device ID
                                 99        If you set it to 00, there is no trans-
        Save &
ENTER                                      mission response cause 00 means
        Go to d02
                                           that is no device
 UNIT   Save & Exit                        Save & go to Normal Mode
                                  - 37 -
 KEY    FUNCTION       DISPLAY   VAL.      DESCRIPTION VAL. DESCRIPTION
                                  0        2400 bps             3   19200 bps
        Select 0 ~ 4
                                  1        4800 bps             4   38400 bps
                        d04
        Save &                    2
ENTER                                      9600 bps
        Go to d05
 UNIT   Save & Exit                        Save & go to Normal Mode
PRINTER TYPE
 KEY     FUNCTION      DISPLAY VAL.                    DESCRIPTION
        Select 0 ~ 2              0        Do not use
        Save &           d07      1        DLP (Label printer)
ENTER
        Go to d08                 2        DEP (Roll printer)
 UNIT   Save & Exit                        Save & go to Normal Mode
AUTOMATIC PRINT
 KEY     FUNCTION      DISPLAY VAL.                    DESCRIPTION
                                  - 38 -
          Select 0 ~ 2            0         Do not use
          Save &          d08     1         When the weight is stable
ENTER
          Go to d09               2         When the weight is OK in limit mode
 UNIT     Save & Exit                       Save & go to Normal Mode
LINE FEED
 KEY        FUNCTION     DISPLAY VAL.                      DESCRIPTION
          Select 0,1,5            1         1 line feed
          Save &          d09      |
ENTER
          Go to d10               5         5 line feed
 UNIT     Save & Exit                       Save & go to Normal Mode
                                  - 39 -
  Tare :        50.00kg                              2004.06.24     14:32:58
  Net    :      72.52kg                              COUNT               123
                                                     WEIGHT         23423.42kg
Note 1. The No which is able to be printed is from 1 to 999.
Note 2. The unit of weight is changed by the mode (kg/lb)
                                        - 40 -
 SELECT CLOCK
    KEY       FUNCTION      DISPLAY VAL.                      DESCRIPTION
            Select 0 ~ 1                 0        Do not use clock
                               d14
 ENTER      Go to next                   1        Use clock
 Change date / time (Ex. 2004.08.31 14:28:47) [d14 = 1]
   KEY        FUNCTION       DISPLAY                          DESCRIPTION
            Increase or      C1 : 04    Year : 2004
            decrease         C2 : 08    Month : 08
            Shift to one     C3 : 31    Day : 31
            digit to left    C4 : 14    Hour : 14
            Save & go to     C5 : 28    Minute : 28
 ENTER
            weighing mode C6 : 47       Second : 47
   UNIT     Save & Exit                 Save & go to Normal Mode
Note 1. Although key clock is set after setting the value of d14 to 1,
           the value of d14(1) is not saved. Always the value of d14 is started to 0.
                                         - 41 -
                                                                      Show the ID of goods
    5      Press [ENTER] key                            Goods(Iron)
                                                                      Display the weight
Note 1. The ID of goods can be from 0 to 19.
                                               - 42 -
12 - 4.   HOW to INPUT the VALUE OF TARE with ID
 STEP          VFD DISPLAY and KEY INPUT             PLATFORM   DESCRIPTION
   1      Press [ G / N ] key for 3 seconds          Empty
          It’s displayed “CodE=z LiM=t tArE=g”,
   2                                                 Empty
          press [ZERO] key
   3      Set the id what you want to
          press [ G / N ] key.
          If the step 2 is displayed,
   4
          press [ZERO] key
   5      Input the value of tare & press [ENTER]
   6      Repeat from step 2 to step 5 if you want
   7      Press [ENTER] key and exit
                                          - 43 -
          “A/D value”, press ENTER Key and then
          after displaying “LoAd” “A/D value”
          put the sample on the platform and
          press [ENTER] key
   6      Display : “Good” “nUMbEr” “0 pcs”
   7      Using the        key, input the number    Sample
   8      Press [ENTER] key                         Sample
                                         - 44 -
          After displaying “SAMPLE” “UnLoAd”
          “A/D value”, press ENTER Key and then
   5      after displaying “LoAd” “A/D value”       Sample
          put the sample on the platform and
          press [ENTER] key
          Display : “Good” “Per”     “0 %”
   6      Using the        key,                     Sample
          input the percent of one sample
   7      Press [ENTER] key                         Sample
  13. Communication
   How to connect PC (COM1)
                                        - 45 -
 OPTION ( RS-485/422 :: COM2 & CLOCK )
                     - 46 -
How to connect to printer (COM2)
                       - 47 -
          ,             ,            ,      Weight Data (8byte)
 ⓐ ⓑ          ⓒ ⓓ           ⓔ ⓕ                                      ⓖ ⓗ ⓘ ⓙ ⓚ
         g                                CR                           LF
 ⓘ                              ⓙ                              ⓚ
         OK signal                        CR                           LF
 ⓛ                              ⓜ                              ⓝ
                                           - 48 -
   Command Mode Protocol
  Command (ASCII code)                            Description                    State
  HI                                 High Limit Value                     Read / Write
  LO                                 Low Limit Value                      Read / Write
  KT                                 Key Tare Value                       Read / Write
  CO                                 Code Value                           Read / Write
  WT                                 Current Weight                       Read
  ZE                                 Operating like the ZERO key          Read
  TR                                 Operating like the TARE key          Read
  GN                                 Operating like the Gross/Net key     Read
  ID                                 Change Device ID                     Read
  HD                                 Operating like the ENTER key         Read
  PR                                 Operating like the PRINT key         Read
  TP                                 Operating like the Total Print key   Read
  PW                                 Power off                            Read
  Read
           1                2                    3              4                  5
   Device ID                    Command                         CR                LF
Note. 1 Device ID is hex and Command is ASCII
[Ex]       Device ID is 13 when user want to know the current weight.
           -> 0x0d 0x57 0x54 0x0d 0x0a
  Write
       1         2      3        4         5            6   7        8       9           10
 Device ID      Command         DATA (Not include decimal point)            CR           LF
Note. 1 Device ID is hex and DATA is ASCII
[Ex]       When user want to change hi limit weight (10.50kg).
           -> 0x02 0x48 0x49 0x30 0x31 0x30 0x35 0x30 0x0d 0x0a
Note. 1 When Device ID and Code is changed, Data value is HEX and 1byte.
P.S.
1. To input the command, set the value D02=1 or 2, D03=3 when com1 uses
   and D05=1 or 2, D06=3 when com2 uses.
                                               - 49 -
   CAS DLP Protocol
 VARIABLE                                    DESCRIPTION
     V00       Gross Weight (8 bytes)
     V01       Tare Weight (8 bytes)
     V02       Net      Weight (8 bytes)
     V03       Barcode (net weight) (8 bytes)
     V04       Number of count when count mode (8 bytes)
     V05       Percentage when percent mode (8 bytes)
It is impossible to print the weight, count and percentage at the same time.
If you do, only one data which is met the current mode can be printed correctly
                                           - 50 -
  ASCII CODE
Letter   Hex   Letter   Hex   Letter     Hex      Letter   Hex   Letter   Hex
         20      4      34      H            48     \      5C      p      70
  !      21      5      35      I            49     ]      5D      q      71
  “      22      6      36      J            4A     ^      5E      r      72
  #      23      7      37      K            4B     _      5F      s      73
  $      24      8      38      L            4C     ‘      60      t      74
  %      25      9      39      M            4D     a      61      u      75
  &      26      :      3A      N            4E     b      62      v      76
  ‘      27      ;      3B      O            4F     c      63      w      77
  (      28      <      3C      P            50     d      64      x      78
  )      29      =      3D      Q            51     e      65      y      79
  *      2A      >      3E      R            52     f      66      z      7A
  +      2B      ?      3F      S            53     g      67      {      7B
  ,      2C     @       40      T            54     h      68      |      7C
  -      2D      A      41      U            55     i      69      }      7D
  .      2E      B      42      V            56     j      6A      ~      7E
  /.     2F      C      43     W             57     k      6B    END      FF
  0      30      D      44      X            58     l      6C
  1      31      E      45      Y            59     m      6D
  2      32      F      46      Z            5A     n      6E
  3      33      G      47      [            5B     o      6F
                                    - 51 -
15.Error Message & Trouble Shooting
                - 52 -
Error                  Reason                                   Solution
Err 01   Initial value of A/D is fail              Check the L/C connector & test
                                                   A/D conversion in Test Mode 2
Err 02   Load cell connection failure,             Check the L/C connector & test
         Error in A/D conversion part              A/D conversion in Test Mode 2
Err 05   Input value is over the range             Input the value from 32 to 255
Err 07   Product ID is larger than 19              The range of Product ID is 0 to 19
Err 08   Hi limit weight is larger than            Set the Hi limit weight to under
         Maximum weight                            the maximum weight
Err 09   Low limit weight is larger                Set the Low limit weight to under
         than hi limit weight                      the Hi limit weight
Err 11   The unit of weight is different           Can’t process cause the unit of
                                                   weight calibration is not same
Err 13   Zero value exceeds the initial            Remove a weight from the platter
         zero range                                and turn on power
Err 21   The resolution exceeds 1/20,000           Lower the resolution
Err 22   The weight for span calibration           The weight of Span calibration
         is set to under 10% of maximum            Should be set to over 10% of max.
         capacity                                  Capacity (Check it in CAL 1)
Err 23   The weight for span calibration           The weight of Span calibration
         is set to over 100% of maximum            Should be set to under 100% of
         capacity                                  max. capacity (Check it in CAL 1)
Err 24   The value of Span is high or low          Adjust resolution
Err 31   The password before and the cur- Input the new password again
         rent password are not same
Err 32   The number of sample is too low           Put more samples or
                                                   Decrease the number of samples
Err 50   Internal memory data is erased            The product is in trouble
                                                   Contact the A/S center
- 53 -