DMRC Project (Mech)
DMRC Project (Mech)
SUBMITTED BY-
                     MECHANICAL ENGINEERING
        DELHI TECHNOLOGICAL UNIVERITY
        ACKNOWLEDGEMENT
It is indeed a great pleasure for me to present this Summer Training Report on Delhi Metro
Rail Corporation as a part of the curriculum of the B.Tech course Mechanical Engineering
I take this golden opportunity to thank all my mentors at DMRC who with their support and
venerated guidance made this training a real success . I express my sincere thanks to officers
of DMRC who inspite of their busy schedule have lent their precious time for helping out me
to understand various system used in DMRC.
Formation of DMRC
A company under the name DMRC was registered on 30.05.1995 under the companies act
for construction and operation of the metro project. DMRC is the joint venture of the
Government of India and Government of National Capital Territory of Delhi. It started
functioning in November 1997. It appointed General consultant in August, 1998 to assist
them for implementation of the project. This is the consortium office international
consultancy company led by Pac Consultants International (PCI), Japan. The whole project
of approximately 200Kms is to be completed in three phases up to 2021, the first phase of the
project, comprising of approximately 62.06Kms, is currently operational.
   It is having 18 stations in Line 1 (Red Line), 10 stations in Line 2 (Yellow Line) and 22
stations in Line 3 (Blue Line).
On the completion of the first phase of the Delhi Metro, it would be catering to around 2.18
million commuters per day resulting in decongestion of the roads. This would also mean that
there would be less number of buses on the roads. It has also reduced the travel time. Also the
pollution level is reduced to about 50%.
Since the first phase of the Delhi Metro is operational a large number of commuters are
having a lot of convenience in reaching their desired destination in the required time.
   Occupies no road space if underground and only about of 2 meter width of the road if
    elevated.
Awards won
The Delhi Metro has been awarded OHSAS (Occupational Health and Safety Assessment
Sequence 18001) by RINA (Registro Italiano Navale India Pvt. Ltd.), Geneva.
To help in proper maintenance the DMRC has been divided into departments and sub
departments:
       Signaling
       Telecom
       Rolling Stock
       P. Way
        AFC
Train Formation
At present each train train set consist of four cars.Both ends of the train-set are Driving
Trailer(DT) cars and middle cars are Motor(M) cars.
The train set can be controlled as a complete unit or as separate units for various maintenance
activities at the depot.
1) 4 car -   DT-M-M-DT
2) 6 car -   DT-M-M-T-M-DT
3) 8 car -   DT-M-M-T-M-T-M-DT (Here T car is the non-driving trailer car.)
Salient Features –
1. Broad Gauge
5. VVVF Control
   16. ATP/ATO
ITEM                                                        SPECIFICATION
                                         INDEX
1. Aircon
5. Coupler
6. Saloon Interior
   •   to control temperature
   •    to control humidity
   •    to supply pure air
Design Conditions
Description                               Condition
No. of passengers :-                      392
Ambient temperature:-                     430 DBT& 33% RH /
                                          390 DBT & 41%RH DBT
Inside condition:-                        330 DBT&/290DBT
Present inside condition:-                240 DBT
Fresh air per passenger :-                2.3 lps
Cooling capacity:-                        41 kw per unit
                                          82 kw per car
Operating modes
                        TEMPERATURE                                          TEMPERATURE
                          FALLING                                               RISING
                                                                               COOL2
                                                          Set Point + 1.0C
                             COOL2                                             COOL1
                                                  O
                                                      o
                                      Set
                                      SETPoint
                                          POINT+ 0.5C
                                                 +1C      Set Point + 0.5C
                             COOL1
                                                                               VENT
                                      SET POINT            SET POINT
VENT
   •   Smoke Mode
In this mode , system shuts off the fresh air intake and provides full recirculation of return
air within the saloon.
Normal operating sub -modes
    • Vent mode :-
air is supplied inside saloon without any cooling
    • Cool-1 mode:-
air is supplied with cooling (only 50% of cooling capacity
is used)
    • Cool-2 mode:-
air is supplied with cooling (100% cooling capacity is used.
   •   Refrigeration Equipment
   •   Air Transfer Equipment
   •   Electrical Equipment
A) Refrigeration equipment
1.Compressor
2. Condenser coil
3. Solenoid valve
4. Thermal exp. Valve
5. Evaporator coil
1. Compressor
The function of the compressor is to pump the refrigerant through the system and to
compress the low pressure, low temperature refrigerant into a high pressure high temperature
super heated vapour, to allow condensing to occur.
2. Condenser
The function of the condenser coil is to reject the heat from refrigerant absorbed by the
evaporator coil and during the compression process
3. T-X valve
The TX valve regulates the refrigerant flow into the evaporator coil, expanding the liquid
from high pressure to low pressure, and causing a large drop in refrigerant temperature.
Refrigerant R22
Range N       -40 ® +10 o C
Factory Superheat    5K
Max bulb temp.       100 o C
Max working pressure        28 bar
4. Evaporator coil
The prime function of the evaporator compartment is to deliver conditioned air to the main
supply air duct that services the vehicle
Its function is to switch off the refrigeration system in case of adverse system condition . It
monitors both the high and low refrigerant pressures. If the low (LP) or high (HP) pressures
reach a predetermined set point, the refrigeration system will be shut down.
              Fresh air
                                             Evaporator
                                                          Supply fan
                                             saloon
                                                                       saloon
1.Supply fan
As the name applies , it supplies the conditioned air inside saloon . It draws back 70% of
return air & 30% of fresh air & moves past t
2.Condenser fan
Its function is draw the atmospheric air through condenser coil , inside which hot refrigerant
is flowing , thus making the heat rejection & condensing the
Their function is to control the fresh air & return( recirculated) air volume as per
requirement.
Configuration
                      Piston
                    compress
       Ai           or VV120                                               Air dryer unit
       r
                                                                           LTZ015-H
                                              Air
                                              Reserv
                                              oir
1.Piston   Compressor
                        i. Main compressor:-
                              1. Discharge air pressure               max. 10 bars.
                              2. Nominal discharge capacity           900 L/min.
                              3. Type                                 piston type.
                              4. motor                                3, 415V AC, 50 Hz, induction
                                  motor
 It have forced air cool type ******** heat exchanger i.e. radiator.
                  It also has a torsion ally rigid bellow type coupling between motor and compressor
                   which allow no rotary vibration.
                  It is mounted with car by wire rope isolators for no resonance throughout the whole
                   compressor speed range.
                  Compressor can be drive by AC, DC and hydraulic motor i.e. very low specific
                   power consumption
                         i. It also has low breakaway torque for low starting current even at low
                            temperature.
2) Air Dryer Unit (LTZ015 –H)
At very high pressure when air is cooled some component of it condense in to liquid which make air
wet. So that why an air dryer unit mounted which perform following function on air:-
                                                                                    92.93     Insulators
                                                                                              (on LTZO15..H)
                                                                                     A        Drainage port
                                                                                     O..      Exhaust port
                                                                                    P1        Air supply port
                                                                                    P2        Air pipe connection to
                                                                                              main reservoir
25      Bracket
34      Duplex piston valve
3.Air Reservoir
There are 2 type of reservoir Main reservoir & Auxiliary reservoir
            1)   BP (Brake Pipe)
            2)   BCU (Brake Control Unit)
            3)   BECU (Brake Electronic Control Unit)
            4)   ASV (Anti Skied Valve)
            5)   BBU (Block Brake Unit)
                                        34.15 KNORR K-ring
                                        34.17    KNORR K-ring
                                        43       Valve magnet
                                        50       Regeneration choke
                                        55       Piston for pre control valve
                                        56       KNORR K-ring
                                        70       KNORR K-ring
                                        71       Valve head for bypass valve
       1)   BAKE PIPE
       i. Service brake
       ii. Blend brake
       iii.Emergency brake
       iv. Parking brake
       v. Holding brake
       vi. BP- back up brake
i. SERVICE BRAKE :-
M car DT car
                                                                 Train line
                                                                 brake demand
  TCU                  TCU
BECU
BECU
Blending request
F set by M & DT
F set by M EP
ED
V1 V2
v. HOLDING BRAKE
   1.It is microprocessor based control system which deals with many type of signal.
   2.It works as an interface between TIMS & BCU.
 D. ASV (Anti Skied Valve)
Wheel slide protection is used to optimize the stopping distance and to avoid the wheel flats
under wheel sliding conditions. Wheel slide protection is active in service brake and
Emergency brake.The wheel slide protection acts per bogie on each car by the dump valves
(G2).
When a potential wheel-slide event is detected, the BECU will release/apply the brakes
through energizing/ de-energizing the magnets of the dump valves or anti skied valve.
                                                                      1     Econnection
                                                                      2     Double valve
                                                                              magnet
                                                                      3     Plate
                                                                      4     Anchor spring
                                                                      5     Housing
                                                                      6     D – piston
                                                                      7     Compressing
                                                                              spring
                                                                      8     Control chamber
                                                                      9     Valve seat Vd
                                                                      10    Bypass nozzle
                                                                      11    Nozzle D
                                                                      12    Bracket
                                                                      13    To brake
                                                                              cylinder
                                                                              pressure
                                                                              supply
                                                                      14    To the brake
                                                                      15    Nozzle C
                                                                      16    Valve seat Vc
                                                                      17    C-piston
                                                                      18    Control chamber
                   19   Outer valve seat
                   20   Inner valve seat
     PARTITION DOOR
     CAB SIDE DOOR
     SALOON DOOR
     EMERGENCY DOOR
     Salient Features of Saloon Door
           Obstruction detection
           Door isolation
           Emergency operation
           Fault diagnosis
                                         110 V DC
       INPUT SIGNALS                      SUPPLY
1.   CLOSE SIGNAL
2.   LOCK SIGNAL
3.   EMERGENCY SIGNAL                   ISOLATION
4.   ZERO SPEED SIGNAL                    SWITCH
SOLENOID
MOTOR ENCODER
SPINDLE SHAFT
SPINDLE NUT
DRIVE BRACKET
DOOR PANEL
                                          DOOR
                                       OPEN/CLOSE
Types of Coupler –
  •  Circuit breaker tripping i.e SFB , CBF , CMB tripping: any circuit breaker gets trips,
     this fault comes.
 CBF-1 or 2 tripped:-     system will run as usual with increased discharge pressure
 CFB- 1&2 tripped :-       system will not run in cool mode
 CMB tripped:-             system will not run in cool mode
 SFB mode:-                system will not run in a any mode
  •   High pressure(HP) fault:- when system pressure increase beyond given safe limit for
      the system, then system gets tripped. If such instances occur more than 3times in a
      hours, then cooling system will shut down.
  •    Low pressure fault: when system pressure decreases beyond given safe limit for the
      system, cooling system will shut down.
• RAT/FAT probe fault:- these faults occurs in case of failure of temperature probe.
  •   COTS / IOAT getting operated:- these are temperature switches , installed inside
      compressor motor winding & inverter area respectively., & gets operated when
      temperature exceeds the given limit.& respective system gets shutdown.