CHEMIGUARD EPOXY 1905 TOPCOAT (HB)
Description and Uses               : A solvent free, high build, epoxy resin coating, heavy duty epoxy product specially designed for floor coating. It
                                       is specially formulated to offer durable protection. It provides chemical and abrasion resistant finish. Excellent
                                       for use in industrial plants, hospitals, car parks, laboratories, or any other surface where a hard and durable film
                                       with chemical resistance required.
                                        Special additive is added to provide fungi and algae growth resistance.
 Type                            : Pure Epoxy Resin and Epoxy Curing Agent
 Color                           :      As specified in color cards.
                                        Special colors could be provided upon special request.
 Finish                          : Satin, semi-gloss or gloss finish
 Fitness of Grind               :       5 Hegman
 Viscosity                      : 1 110± 5 K.U. ( system )
 Total Solid by Volume          : 99 % ± 1
 Specific Gravity               : 1.7± 0.05 ( system )
 Curing Mechanism                :      Crosslink polymerization
 Performance                     : Compressive Strength:             70 N/ mm²
                                       Flexural strength:            40 N/mm²
                                       Tensile strength:             20 N/mm²
                                       Bond strength:                Greater than cohesive strength of concrete
                                       Shore D Hardness:             100
                                       Physical Properties
                                          Abrasion resistance (pure white)…132mg. ASTM D4060 CS-17 wheel, 1000 cycles.
                                          Direct impact resistance (ASTM G14) 84 in lb.
                                          Dry heat resistance 250°F or (121°C) (ASTM D2485, discolor)
                                          Elcometer adhesion (ASTM D4541) 750 psi exterior durability …excellent (with non progressive chalk
                                              face developing in 3-6 months)
                                          Flexibility passes (ASTM, 180° Bend, 1/4° mandrel)
                                          Moisture condensation resistance No Failure (ASTM D4585, 100°F, 1500 hours)
                                          Pencil hardness (ASTM D3363) 3H
                                          Salt fog resistance good (ASTM B117, 1000 hrs)
                                          Scrub resistance no gloss change (ASTM D2486, 9700 cycles)
                                          Thermal shock (ASTM D2246, 5 cycles)
                                          Good wash ability and stain resistance max 25 cycles for complete removal of: lipstick, butter, tea,
                                              kitchen, coke, fruit, juice
[Chemiguard Epoxy 1905 HB] – April 2006
Chemipaint, UAE, Lebanon & Irbil
All information is correct at the date of publication. Published technical data and instructions are subject to change without prior notice       Page 1/3
CHEMIGUARD EPOXY 1905 TOPCOAT (HB)
                                             Wet heat resistance (not immersion) 100°F (38°) Fire resistance: the system will exceed the fire spread
                                              requirements of 25 and a smoke development of 50 when tested in accordance with ASTM E84 on
                                              asbestos cement boards.
                                     Resistance Guide
                                             I. Excellent Resistance:
                                                1. Jet fuel A1 in accordance with ASTM D543.
                                                2. Resistance to fumes, splash and spillage not immersion ASTM D3912
                                                3. Aliphatic hydrocarbon solvents
                                                4. Oils (cutting, vegetable, lubricating )
                                                5. Fresh water & salt water
                                             II. Moderate Resistance:
                                                1. Alcohol, selected chlorinated solvents, formaldehyde, glycol,, ethers:
                                                2. Aromatic hydrocarbon solvents
                                     Acid Resistance
                                          Acetic: 5%
                                          Hydrochloric: 10%
                                          Muriatic: 10%
                                          Citric: 10%
                                          Lactic: 85%
                                          Linseed fatty acids-nitric: 10%
                                          Tanic: 50%
                                          Sulfuric: 10%
                                     Alkali Resistant
                                          Ammonium hydroxide 10%
                                          Potassium hydroxide 10%
                                          Sodium hydroxide 50%
                                          Tri-sodium phosphate 5%
 Shelf Life                     :    2 years unopened @ 75°F or (24°C)
 Spreading Rate                 :    Approximately 2.5 m² / ltr @ 400 microns DFT
 Drying Time                     :   Initial Cure:                              24 hours
                                     Max. over coating time:                    36 hours
                                     Full cure:                                 7 days
                                     Full chemical resistance:                  7 days
                                     Pot life:                                  Approximately 40 mins. depending upon ambient temperature.
 Packaging                      :    In cylindrical containers of the following capacities:
                                     Epoxy: 1U.S Gallon                                  Hardener: 1 Liter – quantity needed for 1 Gallon
                                               1 Pail                                              1 Gallon – quantity needed for 1 Pail
[Chemiguard Epoxy 1905 HB] – April 2006
Chemipaint, UAE, Lebanon & Irbil
All information is correct at the date of publication. Published technical data and instructions are subject to change without prior notice   Page 2/3
CHEMIGUARD EPOXY 1905 TOPCOAT (HB)
 Surface Preparation             :   The concrete substrate must be cured for minimum 28 days and have a moisture content of less than 5%
                                     prior to application of epoxy coating. It is most important that the substrate must be correctly prepared prior
                                     to application. It should be sound and free from contamination such as oil, grease, mortar and paint splashes
                                     or any curing compound residues. Laitence can be removed by the use of mechanical methods, dust and
                                     other debris should be removed by vacuum cleaning. Sound and clean substrate is essential to achieve
                                     maximum adhesion. Oil and grease penetration should be removed by the use of proprietary chemical
                                     degreaser or grinding media.
 Application Condition :             Temperature (air, surface, material):
                                     55°-95°F or 13°C-35°C (At least 5°F above the dew point)
                                     Relative humidity: 85 % maximum.
 Method of Application                :   Thinning: An epoxy thinner is used for cleaning the paint tools only.
                                          Stir both epoxy base and catalyst separately thoroughly, then mix together and again stir thoroughly.
                                          The mixture must stand for at least 10 mins. before using.
                                          This product may be applied by any of the following:
  1. Airless Spray                    :   Pressure: 2500PSI                     Filter: 60mesh                           Tip: 0.15˝
  2. Brush                            :   China Bristle
  3. Roller                           :   ¼” to ¾ “ nap.
 Application System              :   Sand blasting is usually recommended vacuum blasting and grit blasting would work
                                     as well, and furthermore it is recommended to:
                                                1.   One coat Chemiguard Epoxy SF Sealer
                                                2.   Two coats of Chemiguard Epoxy 1905 Topcoat (HB)
 Precautions                     :   Combustible. Keep away from heat and open flame.
                                     Contains Epoxy Resin and Xylene.
                                     Avoid contact with skin and eyes.
                                     Do not take internally.
                                     Close container after each use.
                                     Protect from freezing.
                                     Keep out of reach of children.
 Clean Up                        :   Clean up tools with epoxy thinner T-011.
 Disposable                      :   Material and all related packing should be properly disposed in accordance with the government requirements
                                     and procedures in addition to the site requirements if applicable.
                                     Empty can should be sent for recycling.
[Chemiguard Epoxy 1905 HB] – April 2006
Chemipaint, UAE, Lebanon & Irbil
All information is correct at the date of publication. Published technical data and instructions are subject to change without prior notice       Page 3/3