Smith Meter® CT Series PD Meter
for Crude Transportation
                                                                                     16" Steel Model M16
                                                                                                         Specifications
Issue/Rev. 0.7 (2/10)									                                                                               Bulletin SS01021							
The Smith Meter® Model M16 Meter is a 16", double-
case, straight-through type, rotary vane, positive displace-
ment flow meter and is part of the Crude Transportation
(CT) Series of large PD meters.
The Crude Transportation Series PD meters incorporate
updated design features including lightened blades, full-
width wear strips, Armalloy coated rollers and cam and
tungsten carbide roller pins to provide extended service
in harsh crude applications.
The Crude Transportation Series is suitable for both crude
oil and refined product applications such as blending,
batching and leak detection as well as traditional custody
transfer applications.
Options
   High Viscosity Meter Clearances – To extend opera-
   tion at maximum flow rate from 200 mPa•s to 2,000              Model M16-S3
   mPa•s.
   High Temperature Meter Clearances – To extend
                                                                  Minimum Flow Rate – Typical Performance
   operating temperatures from 105°F to 200°F (41°C
   to 93°C).
                                                                                              Viscosity (Centipoise – mPa•s)
                                                                      Linearity1   Units
   All Iron Trim – For operating temperatures above                                          1      5       20     100     200
   200°F (93°C).                                                                   BPH     1,400   560     140      36    18.0
                                                                       ±0.15%
   NACE Construction – Special components available                                m3/h     222     89      22       6     2.9
   to meet requirements of NACE Standard MR-01-75.                                 BPH     1,050   420     105      27    14.0
                                                                       ±0.25%
                                                                                   m3/h     167     67      17       4     2.2
                                                                                   BPH      700    280      70      18    10.0
                                                                       ±0.50%
Operating Specifications                                          	
                                                                                   m3/h     111     45      11       3     1.6
Maximum Flow Rate                                                 Repeatability
	                                          BPH	m3/h               ±0.02%
Continuous Rating -
Standard Trim	                            12,500	      2,000      Viscosity
Continuous Rating -                                               Standard: 200 mPa•s2 (1,000 SSU) maximum.
All Iron Trim	                            9,375	       1,500      Optional: 2 Pa•s (10,000 SSU) maximum – specify “High
                                                                  Viscosity Meter Clearances.”
                                                                  Over 2 Pa•s: Specify “High Viscosity Meter Clearances”
                                                                  and derate maximum flow rate in direct proportion to vis-
                                                                  cosity over 2 Pa•s (e.g., at 4 Pa•s, derate Maximum Flow
                                                                  Rate to 50% of normal continuous rating – 6,250 BPH).
1	 Based on a maximum flow rate of 12,500 bph (2,000 m3/h).
2	 1,000 mPa•s.
                                              The Most Trusted Name In Measurement
Temperature Ranges                                                         Pressure Drop (∆P)
  Operating:
  Standard Trim, Standard Meter Clearances:                                                           Flow - Cubic Meters per Hour
  -20°F to 105°F (-29°C to 41°C).                                                       0        400       800     1,200    1,600   2,000   2,400
                                                                                  5.0                                                           32
  Standard Trim, High Temperature Meter Clearances:                                         Data based on 0.82 sp. gr.,
  -20°F to 200°F (-29°C to 93°C).                                                           2 Centipoise product.                                 28
                                                                                  4.0
  All Iron Trim, Standard Meter Clearances:                                                                                                       24
  -20°F to 400°F (-29°C to 205°C).                                                                                                                20
                                                                                  3.0
                                                                            ∆P                                                                       ∆P
  Elastomers:                                                               psi                                                                   16 kPa
  Buna N:	       -20°F to 255°F (-29°C to 108°C).                                 2.0                                                             12
  Viton:	        10°F to 400°F (-12°C to 205°C).
                                                                                                                                                  8
Meter Gearing                                                                     1.0
                                                                                                                                                  4
One barrel or 50 dekalitres per revolution of meter
calibrator output shaft.                                                           0                                                              0
                                                                                        0        2        4      6      8     10    12       14
                                                                                                     Flow - Barrels per Hour (x 1000)
Maximum Working Pressure
   Model	           Flange           PSI	               kPa
	 M16-S3	             150	  285 	  1,9654
                                        4
	 M16-S5	             300	  300	  2,068                                    Materials of Construction
	 M16-S6	             300	  7404	  5,1024
	                                                                            Trim               Housing             Internals                Seals
Note: Flange Class per ANSI B16.5 Raised Face.                             Standard              Steel             Iron, Steel,            Buna N,
                                                                                                                 Stainless Steel,      Viton, or PTFE3
Installation                                                                                                        Aluminum
It is recommended that the meter be protected with a                        All Iron             Steel           Delete Aluminum           Buna N,
suitable mesh strainer.	                                                                                                               Viton, or PTFE3
Dimensions
Inches (mm)
                                                      Meter Anchor Bolt Holes
                                                       6 - 1-1/8" (29) Bolt Holes
                                                 on a 33.0" (838) Diameter Bolt Circle
Note: Dimensions – Inches to the nearest tenth (millimetres to the nearest whole mm), each independently dimensioned from respective
engineering drawings.
     Model                A                 B                     C                         D                       E               Weight – lb (kg)
     M16-S3          46.0" (1,168)      30.5" (775)           3.5" (89)            14.0" (355)                19.4" (493)             6,505 (2,927)
     M16-S5          46.0" (1,168)      30.5" (775)           3.5" (89)            14.0" (355)                19.4" (493)             7,400 (3,330)
     M16-S6          47.0" (1,194)      30.5" (775)           4.0" (102)           14.4" (366)                19.8" (503)             9,600 (4,320)
3 Polytetrafluoroethylene (PTFE).
4 Maximum working pressure at 100° F (38° C).	
Page 2 • SS01021	                                                                                                                    Issue/Rev. 0.7 (2/10)
Ordering Information
    Application                       Batching, Loading, Blending, Inventory, Custody Transfer, etc.
    Operating Conditions              Liquid – Name and sp. gr., Flow Range5, Temp Range5, Viscosity Range5, Maximum
                                      Working Pressure.
    Seals                             Buna-N or Viton
    Units of Registration             Gallons, Barrels, Cubic Meters, Tons.
    Direction of Flow                 Left to right flow (as viewed above) is standard and will be supplied unless right to
                                      left flow is specified.
    Options and Accessories           As required.	
5	 Specify: minimum/normal/maximum.
Issue/Rev. 0.7 (2/10)	                                                                                          SS01021 • Page 3	
Revisions included in SS01021 Issue/Rev. 0.7 (2/10):
  Page 2 - Maximum Working Pressure M16-S6, PSI and kPa revised.
  Editorial Change - 10/27/2010 - page 2, dimensions of A corrected.
Editorial Change: 11/13: Seals - material reference changed to PTFE.
Headquarters:                           Operations:                                   The specifications contained herein are subject to change without notice and any user of said
500 North Sam Houston Parkway West,     Measurement Products and Equipment:           specifications should verify from the manufacturer that the specifications are currently in effect.
Suite 100, Houston, TX 77067 USA        Ellerbek, Germany +49 (4101) 3040             Otherwise, the manufacturer assumes no responsibility for the use of specifications which
Phone: +1 (281) 260 2190                Erie, PA USA +1 (814) 898 5000                may have been changed and are no longer in effect.
Fax: +1 (281) 260 2191
                                                                                      Contact information is subject to change. For the most current contact information, visit our
                                        Integrated Measurement Systems:
                                                                                      website at www.fmctechnologies.com/measurementsolutions and click on the “Contact Us”
                                        Corpus Christi, TX USA +1 (361) 289 3400      link in the left-hand column.
                                        Kongsberg, Norway +47 (32) 286700
                                                                                      www.fmctechnologies.com/measurementsolutions
Printed in U.S.A. © 2/10 FMC Technologies Measurement Solutions, Inc. All rights reserved. SS01021 Issue/Rev. 0.7 (2/10)