Hello!
I'd like to ask you how to deal with situation like below.
I run bbf against HDD, hdd is connected to motherboard using controller H310 flashed to IT firmware (
01:00.0 RAID bus controller: Broadcom / LSI SAS2008 PCI-Express Fusion-MPT SAS-2 [Falcon] (rev 03)
Subsystem: Dell SAS2008 PCI-Express Fusion-MPT SAS-2 [Falcon]
Kernel driver in use: mpt3sas
Kernel modules: mpt3sas
)
Hdd has non zero values in Offline_Uncorrectable, Current_Pending_Sector and Reallocated_Sector_Ct fields.
In dmesg I have:
[26058.722312] mpt2sas_cm0: log_info(0x31080000): originator(PL), code(0x08), sub_code(0x0000)
[26058.722408] sd 9:0:1:0: [sde] tag#2800 UNKNOWN(0x2003) Result: hostbyte=0x0b driverbyte=0x00 cmd_age=2s
[26058.722487] sd 9:0:1:0: [sde] tag#2800 CDB: opcode=0x28 28 00 bb c8 cf 28 00 01 00 00
[26058.722563] blk_update_request: I/O error, dev sde, sector 3150499624 op 0x0:(READ) flags 0x80700 phys_seg 17 prio class 0
[26058.722660] sd 9:0:1:0: [sde] tag#2799 UNKNOWN(0x2003) Result: hostbyte=0x00 driverbyte=0x08 cmd_age=2s
[26058.722738] sd 9:0:1:0: [sde] tag#2799 Sense Key : 0x3 [current]
[26058.722795] sd 9:0:1:0: [sde] tag#2799 ASC=0x11 ASCQ=0x0
[26058.722852] sd 9:0:1:0: [sde] tag#2799 CDB: opcode=0x28 28 00 bb c8 ce 28 00 01 00 00
[26058.722927] blk_update_request: critical medium error, dev sde, sector 3150499517 op 0x0:(READ) flags 0x80700 phys_seg 7 prio class 0
[26061.096262] mpt2sas_cm0: log_info(0x31080000): originator(PL), code(0x08), sub_code(0x0000)
[26061.096345] mpt2sas_cm0: log_info(0x31080000): originator(PL), code(0x08), sub_code(0x0000)
[26061.096420] mpt2sas_cm0: log_info(0x31080000): originator(PL), code(0x08), sub_code(0x0000)
[26061.096499] mpt2sas_cm0: log_info(0x31080000): originator(PL), code(0x08), sub_code(0x0000)
[26061.096571] mpt2sas_cm0: log_info(0x31080000): originator(PL), code(0x08), sub_code(0x0000)
[26061.096644] mpt2sas_cm0: log_info(0x31080000): originator(PL), code(0x08), sub_code(0x0000)
[26061.096730] sd 9:0:1:0: [sde] tag#2757 UNKNOWN(0x2003) Result: hostbyte=0x00 driverbyte=0x08 cmd_age=2s
[26061.096806] sd 9:0:1:0: [sde] tag#2757 Sense Key : 0x3 [current]
[26061.096861] sd 9:0:1:0: [sde] tag#2757 ASC=0x11 ASCQ=0x0
[26061.096916] sd 9:0:1:0: [sde] tag#2757 CDB: opcode=0x28 28 00 bb c8 ce bd 00 00 01 00
[26061.096988] blk_update_request: critical medium error, dev sde, sector 3150499517 op 0x0:(READ) flags 0x0 phys_seg 1 prio class 0
[26061.097070] Buffer I/O error on dev sde2, logical block 1003013821, async page read
kernel 5.9.0
Is t something you can improve in bbf, maybe I should native SATA controller to connect hdd to motherboard? Maybe something else?