                                                                                                      Edition: 2013-05
   Type WE                                                                                            Replaces: 08.08
                                                               ▶▶   Size 10
                                                               ▶▶   Component series 3X; 4X
                                                               ▶▶   Maximum operating pressure 315 bar [4569 psi]
                                                               ▶▶   Maximum flow 120 l/min [31.7 US gpm]
H5958
Features Contents
Ordering codes
  01       02      03    04    05            06   07      08   09   10   11           12    13    14    15    16
          WE       10                 /           C                              /                            *
 01      3 main ports                                                                                                                   3
         4 main ports                                                                                                                   4
02 Directional valve WE
03 Size 10 10
04 Symbols e.g. C, E, EA, EB, etc; for the possible version, see page 3
Electrical connection
  10     Individual connection
         Without mating connector; connector DIN EN 175301-803                                                                        K4 1)
         Central connection
         Cable entry at the cover, with indicator light                                                                                DL
         Central plug-in connection at the cover, with indicator light (without mating connector)                                    DK6L
         For further electrical connections, see data sheet 08010
Seal material
  13     NBR seals                                                                                                                  no code
         FKM seals                                                                                                                     V
         Attention: Observe compatibility of seals with hydraulic fluid used! (Other seals upon request)
Symbols
A B A B A B A B
          a           b                     a    b                       a    0        b
                                                                                            a
                                                                                                    a    0     b
                                                                                                                       b
                                a                         b
                   P T                          P T                          P T                        P T
                   A B                          A B                          A B                        A B
                                                                                                                   = .A 1)
          a           b         a           a    b        b   = …/O..    a    0             a       a    0
                   P T                          P T                          P T                        P T
                   A B                          A B                          A B                        A B
                                                                                                                     = .B
          a           b         a           a    b        b   = …/OF..        0        b                 0     b       b
                   P T                          P T                          P T                        P T
=A = E 1)
=C =F
=D =G
                                                                                                                    =H
                   A B                          A B
                      a             b            a    b
                                        a                      b
                                                                                                                    =J
                   P T                          P T
=B =L
=Y =M
=P
=Q
=R
=T
1)	   Example:                                                                                                      =U
      Symbol E with spool position "a", ordering code ..EA..
                                                                                                                    =V
       Notices!
  Representation according to DIN ISO 1219-1.
  Hydraulic interim positions are shown by dashes.
                                                                                                                    =W
Function, section
The directional valve type WE is a solenoid actuated direc-     When the electronic solenoid (2) is de-energized, the
tional spool valve. It controls the start, stop and direction   return spring (4) pushes the control spool (3) back to its
of a flow.                                                      rest position.
The directional valve basically consists of the housing (1),    A manual override (6) allows for the manual switching of
one or two electronic solenoids (2), the control spool (3),     the valve without solenoid energization.
and the return springs (4).                                     To ensure proper functioning, make sure that the pres-
In the de-energized condition, the control spool (3) is held    sure chamber of the solenoid is filled with oil.
in the central position or in the initial position by the
return springs (4) (except for version "O"). The control
spool (3) is actuated by wet-pin electronic solenoids (2).      For additional functions, see page 5.
The force of electronic solenoid (2) acts via the plunger (5)
on the control spool (3) and pushes the latter from its rest
position to the required end position. This enables the
necessary direction of flow from P to A and B to T or P to
B and A to T.
6 2 5 4 1 3 4 5 2 6
A B
"a" "b"
                 Type .WE 10 E…
                                                  TA     A P B         TB
Function, section
"a"
Technical data
(for applications outside these parameters, please consult us!)
    general
    Weight                                                                                Individual connection             Central connection
                               –	Valve with one solenoid                 kg [lbs]               3.6 [7.9]                         3.5 [7.7]
                               –	Valve with two solenoids                kg [lbs]               4.4 [9.7]                         4.3 [9.5]
    Installation position                                                           Any
    Ambient temperature range                                                °C [°F] –30 … +50 [–22 … +122] (NBR seals)
                                                                                     –20 … +50 [–4 … +122] (FKM seals)
    MTTFd values according to EN ISO 13849                                   Years 150 (for further details see data sheet 08012)
    hydraulic
    Maximum operating pressure        –	Port A, B, P                    bar [psi] 315 [4569]
                                      –	Port T                          bar [psi] 160 [2320]
                                                                                  With symbols A and B, port T has to be used as leakage oil con-
                                                                                  nection if the operating pressure exceeds the tank pressure.
    Maximum flow                                                  l/min [US gpm] 120 [31.7]
    Flow cross-section                –	Symbol V                     mm2 [inch2] 11 [0.017] (A/B to T); 10.3 [0.016] (P to A/B)
    (spool position 0)                –	Symbol W                     mm2 [inch2] 2.5 [0.004] (A/B to T)
                                      –	Symbol Q                     mm2 [inch2] 5.5 [0.009] (A/B to T)
    Hydraulic fluid                                                                 See table below
    Hydraulic fluid temperature range                                        °C [°F] –30 … +80 [–22 … +176] (NBR seals)
    (at the valve operating ports)                                                   –20 … +80 [–4 … +176] (FKM seals)
    Viscosity range                                                 mm2/s [SUS] 2.8 … 500 [35 … 2320]
    Maximum admissible degree of contamination of the hydraulic fluid -             Class 20/18/15   1)
Technical data
(for applications outside these parameters, please consult us!)
 electric
 Voltage type                                                                    Alternating voltage 50/60 Hz
 Available voltages 2) (For ordering codes for AC voltage                     V 42, 110, 230
 solenoids, see below)
 Voltage tolerance (nominal voltage)                                          % ±10
 Power consumption                                                            W –
 Holding power                                                               VA 90
 Switch-on power                                                             VA 550
 Duty cycle (ED)                                                              % 100
 Switching time according            –	ON                                    ms 15 … 25
 to ISO 6403                         –	OFF                                   ms 20 … 30
 Maximum switching frequency                                                1/h 7200
 Maximum surface temperatures of the coil      3)                         °C [°F] 180 [356]
 Protection class according to DIN EN 60529                                      IP 65 with mating connector mounted and locked
 Insulation class VDE 0580                                                       H
 Electrical protection                                                           Every solenoid must be protected individually, using a suitable
                                                                                 fuse with tripping characteristic K (inductive loads).
 Behavior in case of an error (solenoid does not switch though)                  The solenoid surface temperature may be exceeded.
    Characteristic curves
    (measured with HLP46, ϑoil = 40 ± 5 °C [104 ± 9 °F])
                                     [180]
                                              12                                                                                           8     A; B               3         3        –        –
Pressure differential in bar [psi]
                                     [160]
                                                                                                                                           7     C                  3         3        4        5
                                     [140]
                                              10
                                                                                                                                           6     D; Y               5         5        6        6
                                     [120]                                                                                                 5     E                  1         1        4        4
                                               8                                                                                           4
                                     [100]                                                                                                 3     F                  2         3        7        4
                                               6                                                                                           2     G                  3         3        6        7
                                      [80]                                                                                                 1
                                                                                                                                                 H                  1         1        6        7
                                      [60]     4                                                                                                 J                  1         1        3        3
                                      [40]                                                                                                       L                   2        2        3        5
                                               2
                                      [20]                                                                                                       M                   1        1        4        5
                                       [0]                                                                                                       P                   4        2        5        7
                                               0         10         20    30      40       50    60     70       80    90     100 110 120        Q                   1        2        1        3
                                                                                                                                                 R                   3        6        4        –
                                               [0]            [4]         [8]          [12]      [16]    [20]          [24]     [28]    [31.7]
                                                                                                                                                 T                   3        3        6        7
                                                                                 Flow in l/min [US gpm]           →                              U; V                2        2        3        3
                                                                                                                                                 W                   2        2        4        5
        Performance limits
        (measured with HLP46, ϑoil = 40 ± 5 °C [104 ± 9 °F])
                                       315
Operating pressure in bar [psi] →
                                    [4569]   315
Operating pressure in bar [psi] →
                                    [1000]                                    11
                                              50
                                                                                           10
                                       [0]
                                               0     10 20 30 40 50 60 70 80                          90 100 110 120
        Performance limits
        (measured with HLP46, ϑoil = 40 ± 5 °C [104 ± 9 °F])
                                    [4569]     315
Operating pressure in bar [psi] →
12 5 11 9 11 5 6 12
                                                                                                                                              15 
           
           15
                                                                      11            6,6
                                                         A                            B
                                          1.1                                                                    1.2
           117 
                                                                                                                                              123 
                                 
                                                                                                                    
                                 40
                                                                                                                    30
       3                                                26             80 
                                                                                                            10                                    3
                        15                95,8                            149,8                      15 
                                     46                       175,8 
                                                                          175,8                         46
                                                                        245,6                               
      13                                  14             2             92,2                        14      13
                                                               18,9    
                        12
F1 F2
                                                                       P
           70 
                        
                                                               TA       A       B        TB
                                                                F4                        F3
15 16
                                                                                                                               0,01/100
                                                                                                                               [0.0004/4.0]
Rzmax 4
16 50
                                       12              8                           7     4
                                         157 
                               114,5 
                           97,5 
Dimensions
 1.1 Solenoid "a"                                                     Subplates according to data sheet 45054 (separate order)
                                                                      G 66/01 (G3/8)
 1.2 Solenoid "b"
                                                                      G 67/01 (G1/2)
  2 Dimension for solenoid without and with concealed manual          G 534/01 (G3/4)
    override "N9" (standard)                                          G 66/12 (SAE-6; 9/16-18) 1)
  3 Dimension for solenoid with manual override "N"                   G 67/12 (SAE-8; 3/4-16) 1)
  4 Cover                                                             G 534/12 (SAE-12; 1-1/16-12) 1)
                                                                      1)	 On request
    Attention!
    The valve may only be operated with properly
    mounted cover.                                                    Valve mounting screws (separate order)
  5 Mating connector without circuitry (separate order,               4 metric hexagon socket head cap screws
    see page 14 and data sheet 08006)                                 ISO 4762 - M6 x 40 - 10.9-flZn-240h-L
                                                                      (friction coefficient µtotal = 0.09 … 0.14);
  6 Mating connector with circuitry (separate order,
                                                                      tightening torque MA = 12.5 Nm [9.2 ft-lbs] ± 10%,
    see page 14 and data sheet 08006)
                                                                      material no. R913000058
  7 Cable gland Pg 16 [1/2" NPT] "DL"                                 or
  8 Angled socket (red, separate order)                               4 hexagon socket head cap screws
    (material no. R900005538)                                         ISO 4762 - M6 x 40 - 10.9 (self procurement)
  9 Name plate                                                        (friction coefficient µtotal = 0.12 … 0.17);
                                                                      tightening torque MA = 15.5 Nm [11.4 ft-lbs] ± 10%
 10 Identical seal rings for ports A, B, P, TA, TB (for valves with
    throttle insert: O ring in channel P)
                                                                      4 UNC hexagon socket head cap screws
 11 Plug screw for valves with one solenoid                           1/4-20 UNC x 1-1/2" ASTM-A574
 12 Space required to remove the mating connector/                    (friction coefficient µtotal = 0.19 … 0.24);
    angled socket                                                     tightening torque MA = 20 Nm [14.7 ft-lbs] ± 15%,
 13 Space required to remove the coil                                 (friction coefficient µtotal = 0.12 … 0.17);
                                                                      tightening torque MA = 14 Nm [10.3 ft-lbs] ± 10%,
 14 Mounting nut, tightening torque MA = 6+2 Nm [4.43+1.48 ft-lbs]
                                                                      material no. R978800710
 15 Porting pattern according to ISO 4401-05-04-0-05 and
    NFPA T3.5.1 R2-2002 D05                                           With different friction coefficients, the tightening torques are to be
 16 Connection TB can only be used in connection with sepa-           adjusted accordingly!
    rately produced bore.
                                                                     Material number
                Valve side
                                                                                                                    With
                                                                           With                      indicator light and Zener diodes-
                                               Without                indicator light                        protection circuit
Port                           Color           circuitry                12 ... 240 V                                24 V
                   a           Gray        R901017010                        –                                         –
M16 x 1.5          b           Black       R901017011                        –                                         –
               a/b             Black              –                    R901017022                               R901017026
                   a         Red/brown     R900004823                        –                                         –
1/2" NPT
                   b           Black       R900011039                        –                                         –
(Pg 16)
               a/b             Black              –                    R900057453                                      –
Further information
   Bosch Rexroth AG                                          © This document, as well as the data, specifications and other information set
   Hydraulics                                                forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
   Zum Eisengießer 1                                         reproduced or given to third parties without its consent.
   97816 Lohr am Main, Germany                               The data specified above only serve to describe the product. No statements
   Phone +49 (0) 93 52 / 18-0                                concerning a certain condition or suitability for a certain application can be
   documentation@boschrexroth.de                             derived from our information. The information given does not release the user
   www.boschrexroth.de                                       from the obligation of own judgment and verification. It must be remembered
                                                             that our products are subject to a natural process of wear and aging.
Notes
  Bosch Rexroth AG                © This document, as well as the data, specifications and other information set
  Hydraulics                      forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
  Zum Eisengießer 1               reproduced or given to third parties without its consent.
  97816 Lohr am Main, Germany     The data specified above only serve to describe the product. No statements
  Phone +49 (0) 93 52 / 18-0      concerning a certain condition or suitability for a certain application can be
  documentation@boschrexroth.de   derived from our information. The information given does not release the user
  www.boschrexroth.de             from the obligation of own judgment and verification. It must be remembered
                                  that our products are subject to a natural process of wear and aging.
Notes