▶▶ Size 10
▶▶ Component series 5X
▶▶ Maximum operating pressure 315 bar [4568 psi]
▶▶ Maximum flow 135 l/min [35.7 US gpm]
HU_1054
Features Inhalt
Ordering code
01 02 03 04 05 06 07 08 09 10 11 12 13
WE 10 5X / S G24 N9 K4 / *
01 3 main ports 3
4 main ports 4
02 Directional valve WE
03 Size 10 10
04 Symbols e.g. C, E, EA, EB, etc; possible version see page 3 e.g. C
Electrical connection
10 Individual connection
Without mating connector; connector according to DIN EN 175301-803 K4 2)
Seal material
12 NBR seals M
FKM seals V
Symbols
A B A B A B A B
a b a b a 0 b a 0 b
a b a b
P T P T P T P T
A B A B
A B A B
a b a b …/OF.. a 0 a a 0 .A 1)
a b
P T P T
P T P T
A B A B
0 b 0 b b .B 1)
P T P T
A
E 1)
C
G
D
D73
H
J
A B A B
J9
J73
a b a b
a b
P T P T L
B Q
Y U
1) Example:
▶▶ Spool E with spool position "a" ordering code ..EA..
▶▶ Spool E with spool position "b" ordering code ..EB..
Notice:
▶▶ Representation according to DIN ISO 1219-1.
Hydraulic interim positions are shown by dashes.
▶▶ Other symbols upon request.
Function, section
The directional valve type WE is a solenoid-actuated direc- After the electronic solenoid (2) has been switched off,
tional spool valve that can be used as electro-magnetic the control spool (3) is pushed back into the central posi-
component. It controls the start, stop and direction of tion or in the initial position.
a flow. A manual override (6) allows the valve to be switched
The directional valve basically consists of housing (1), one manually without solenoid energization.
or two electronic solenoids (2), the control spool (3), and To ensure proper functioning, care must be taken that
the return springs (4). the pressure chamber of the solenoid is filled with oil.
In the de-energized condition, the control spool (3) is held
in the central position or in the initial position by the
return springs (4).
In case of energization of the wet-pin electronic sole-
noid (2), the control spool (3) moves out of its rest posi-
tion into the required end position. In this way, the
required direction of flow according to the selected sym-
bol is released.
6 2 5 4 1 3 4 5 2 6
„a“ „b“
TA A P B TB
Type .WE 10 S…
Technical data
(for applications outside these parameters, please consult us!)
general
Weight ▶▶ Valve with one solenoid kg [lbs] 3.79 [8.37]
▶▶ Valve with two solenoids kg [lbs] 5.09 [11.23]
Installation position Any 1)
Ambient temperature range °C [°F] –20 … +50 [–4 … +122] (NBR seals)
–15 … +50 [+5 … +122] (FKM seals)
Storage temperature range °C [°F] –20 … +50 [–4 … +122]
hydraulic
Maximum operating pressure ▶▶ Port A, B, P bar [psi] 315 [4568]
▶▶ Port T bar [psi] 210 [3050]; Tank pressure (standard)
Maximum flow l/min [US gpm] 135 [35.7]
Hydraulic fluid See table below
Hydraulic fluid temperature range °C [°F] –20 … +80 [–4 … +176] (NBR seals)
(at the valve working ports) –15 … +80 [+5 … +176] (FKM seals)
Viscosity range mm2/s [SUS] 2.8 … 500 [35 … 2320]
Maximum admissible degree of contamination of the hydraulic Class 20/18/15 2)
Important notices on hydraulic fluids: ▶▶ There may be limitations regarding the technical valve data
▶▶ For further information and data on the use of other hydraulic (temperature, pressure range, life cycle, maintenance
fluids, please refer to the data sheets above or contact us. intervals, etc.).
▶▶ The ignition temperature of the hydraulic fluid used must be
50 K higher than the maximum surface temperature.
Technical data
(for applications outside these parameters, please consult us!)
electric
Voltage type Direct voltage
Nominal voltage according to VDE 0580 V 24
Voltage tolerance (nominal voltage) % ±10
Nominal power according to VDE 0580 W 39
Duty cycle % 100 (S1 according to VDE 0580)
Switching time 3) ▶▶ ON Pressure change 5% ms 54 … 138
Pressure change 95% ms 98 … 201
▶▶ OFF Pressure change 5% ms 15 … 126
Pressure change 95% ms 38 … 173
Switching time accord- ▶▶ ON ms 45 … 60
ing to ISO 6403 4) ▶▶ OFF ms 20 … 30
Maximum switching frequency 1/h 15000
Protection class according to DIN EN 60529 IP65
Maximum surface temperature of the coil 5) °C [°F] 120 [248]
Insulation class VDE 0580 F
Protection class according to VDE 0580 I
Electrical protection Every solenoid must be protected individually, using a suitable
fuse with tripping characteristic K (inductive loads). The valve
must be installed on a surface that is included in the equipoten-
tial bonding.
Characteristic curves
(measured with HLP46, ϑoil = 40 ± 5 °C [104 ± 9 °F])
[305] 21
Symbol Direction of flow
20
[280] 7 P–A P–B A–T B–T
A 6 4 – –
[260] 18 5
B 6 4 – –
[240] 8
16 C 1 2 3 3
[220] 6 D 1 3 3 3
14 D/OF 2 3 3 4
[200] 4
E 2 2 4 5
[180] G 7 7 5 3
12
[160] 3 H 1 1 3 4
10 J 2 2 4 5
[140] 2
J9 2 2 8 4
[120] 8 L 2 2 4 5
1
[100] Q 3 3 4 4
6 U 2 2 4 5
[80]
Y 2 1 1 4
[60] 4
[40]
2
[20]
[0]
0 10 20 30 40 50 60 70 80 90 100 110 120 135
[0] [4] [8] [12] [16] [20] [24] [28] [32] [35.7]
[725] 50
12 Symbol Direction of flow
→
40 D73 12 13 13 12
J73 9 10 9 11
[500]
30
[400]
11
[300] 20 9
10
[200]
10
[100]
[0]
0 10 20 30 40 50 60 70 80 90 100 110 120 135
[0] [4] [8] [12] [16] [20] [24] [28] [32] [35.7]
Performance limits
(measured with HLP46, ϑoil = 40 ± 5 °C [104 ± 9 °F])
Solenoid side
[4568] 315
300 Symbol Characteristic
Operating pressure in bar [psi] →
11 3
[4000] curve
250 A 1
5 8
8 B 2
[3000] 200
D; Y; C 3
2
1 D/OF
150
[2000] D73 4
E 5
100
G 6
[1000]
50 H 7
J 8
[0]
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 J9 9
J73 10
[0] [4] [8] [12] [16] [20] [24] [28] [32] [37] L 11
Flow in l/min [US gpm] → Q 12
U 13
[4568] 315
300
Operating pressure in bar [psi] →
[4000] 12 13
7
250
10 4
[3000] 200
6
9
150
[2000]
100
[1000]
50
[0]
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140
[0] [4] [8] [12] [16] [20] [24] [28] [32] [37]
Flow in l/min [US gpm] →
7 2 6 4 6 2 3 7
[0.59]
15 [0.59]
15
Ø10.8 Ø6.6
1.1 A [Ø0.43] [Ø0.26] B 1.2
80 [3.15]
[1.18]
40 [1.57]
30
[1.02] 26 80 [3.15]
5
75 120 [4.72] 174 [6.85] 75
[2.59] [2.59]
8 9 10 11 9 8
12 [0.47]
92.2 [3.63]
19.1 [0.75]
F1
P F2
A B
70 [2.76]
TA TB
F4 F3
0,01/100
[0.0004/4.0]
Rzmax 4
Dimensions
Electrical con- Voltage data in Nominal voltage Rated current Rated current Rated voltage of external
nection the valve valve solenoid valve solenoid external miniature fuse: miniature fuse:
type code in V DC in A Medium time-lag (M) accor- Medium time-lag (M) accor-
ding to DIN 41571 and ding to DIN 41571 and
EN/IEC 60127 EN/IEC 60127
in mA in V
K4 G24 24 1.07 1.25 250
Notice:
Corresponding to the rated current, a fuse according to
DIN 41571 and EN / IEC 60127 has to be connected ahead of
every valve solenoid (max. 3 x Irated).
The shut-off threshold of the fuse has to match the prospective
short-circuit current of the supply source.
The prospective short-circuit current of the supply source may
amount to a maximum of 1500 A.
More information
Bosch Rexroth AG © This document, as well as the data, specifications and other information set
Hydraulics forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
Zum Eisengießer 1 reproduced or given to third parties without its consent.
97816 Lohr am Main, Germany The data specified above only serve to describe the product. No statements
Phone +49 (0) 93 52 / 18-0 concerning a certain condition or suitability for a certain application can be
documentation@boschrexroth.de derived from our information. The information given does not release the user
www.boschrexroth.de from the obligation of own judgment and verification. It must be remembered
that our products are subject to a natural process of wear and aging.