CMR 9 CEILING MOUNT LINE VOLTAGE PASSIVE INFRARED (PIR) STANDARD RANGE 360o sensor SPECIFICATIONS FEATURES 100% Digital PIR Detection, Excellent RF Immunity 360o Coverage Pattern Self-Contained Relay, no power pack Needed, no minimum load Requirements Interchangeable Hot and load Wires, Impossible to Wire Backwards Push-B

Uploaded by

Shaun Stanier
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
596 views2 pages

CMR 9

CMR 9 CEILING MOUNT LINE VOLTAGE PASSIVE INFRARED (PIR) STANDARD RANGE 360o sensor SPECIFICATIONS FEATURES 100% Digital PIR Detection, Excellent RF Immunity 360o Coverage Pattern Self-Contained Relay, no power pack Needed, no minimum load Requirements Interchangeable Hot and load Wires, Impossible to Wire Backwards Push-B

Uploaded by

Shaun Stanier
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

®

CMR 9
STANDARD RANGE 360º SENSOR
CEILING MOUNT • LINE VOLTAGE • PASSIVE INFRARED (PIR)

SPECIFICATIONS OVERVIEW OPTIONS


The CMR 9 Series Standard Range 360°
occupancy sensor incorporates Passive Infrared
FEATURES (PIR) detection technology into an attractive OCCUPANCY CONTROLLED
100% Digital PIR Detection, line powered occupancy sensor that provides DIMMING (D)
Excellent RF Immunity amazing sensitivity to small motions (e.g. • Provides dimming output to control
360º Coverage Pattern hand movements) and excellent payback. The 0-10 VDC dimmable ballasts
Self-Contained Relay, CMR 9 is an economical solution for providing • Provides a second occupancy time-
No Power Pack Needed automatic lighting control where a wall switch out period that enables the lights to go
No Minimum Load Requirements replacement sensor is not applicable. With an to a dim setting before turning off
Interchangeable Hot & Load Wires, integrated line switching relay, the CMR 9 is • Adjustable max/min dim setting
Impossible to Wire Backwards perfect for applications where locating a power
Push-Button Programmable pack is difficult, such as retrofitting rooms with PHOTOCELL (P)
Adjustable Time Delays concrete or inaccessible ceilings. For rooms with • Auto set-point calibration
No Field Calibration or Sensitivity obstructions, the CMR PDT 9 Series sensor is • Two selectable modes of operation
Adjustments Required recommended. • On/Off mode: Photocell has full
Convenient Test Mode control during periods of occupancy
100 hr Lamp Burn-in Timer SENSOR OPERATION • Inhibit mode: Photocell can prevent
Green LED Indicator The sensor detects changes in the infrared lights from turning on if adequate
energy given off by occupants as they move daylight is available, but cannot turn
LAMPMAXIMIZER® TECHNOLOGY within the field-of-view. When occupancy is lights off
• Protects Lamp Life while detected, a self-contained relay switches the
Maximizing Energy Savings PHOTOCELL w/ DIMMING (ADC)
connected lighting load on. The sensor is line • Photocell within sensor maintains
• Minimum On Timer (15 min default) powered, switches line voltage, and requires no
• Occ. Time Delay (10 min defatult) total room light level by controlling
field calibration or sensitivity adjustments. levels of 0-10 VDC dimmable ballasts
• LampMaximizer+ Mode -
Optimizes Lamp Life & Energy • Photocell also has full on/off control
LAMPMAXIMIZER® during periods of occupancy
Savings (disabled by default) This sensor also contains patent pending
• Switch Counter (in 1000’s) • Provides a second occupancy time-
LampMaximizer technology that allows users out period that enables the lights to go
• Total Lamp On Time (in khrs) to aggressively target energy savings while still to a dim setting before turning off
PHYSICAL SPECS protecting lamp life. A minimum on timer, factory
SIZE 4.55” Dia. (11.56 cm) set at 15 minutes, helps preserve lamp life by Note: LampMaximizer+ features not
1.55” Deep (3.94 cm) eliminating all lamp cycles shorter than lamp available with ADC option
WEIGHT 6 oz warranties specify.
347 VAC (347)
MOUNTING 3.5” Octagon Box • Allows sensor to be powered from
Single Gang Handy Box A standard occupancy time delay is also present
that ensures lights turn off (assuming minimum on and switch 347 VAC
COLOR White
timer has elapsed) if no occupancy is detected. LOW TEMP/HIGH HUMIDITY (LT)
ELECTRICAL SPECS This timer is factory set at 10 minutes to promote • Sensor is corrosion resistant to
MAXIMUM LOAD energy savings, but is adjustable between 30 moisture
800 W @ 120 VAC seconds and 20 minutes. These adjustments • Operates down to -40º F/C
1200 W @ 277 VAC can be done manually, through the units push-
1500 W @ 347 VAC button, or automatically every two weeks through
MINIMUM LOAD None an advanced mode, called LampMaximizer+,
MOTOR LOAD 1/4 HP that determines the optimum time delay in order
FREQUENCY 50/60 Hz to maximize both lamp life and energy savings.
DIMMING LOAD Sinks < 20mA; Additionally, this sensor maintains statistics on
~40 Ballasts @ .5mA each total lamp on time and number of cycles.

ENVIRONMENTAL SPECS
OPERATING TEMP
14º to 160º F (-10º to 71º C)
STORAGE TEMP
-14º to 160º F (-26º to 71º C) C US LISTED
RELATIVE HUMIDITY
20 to 90% non-condensing TITLE 24
SILICONE FREE MADE in U.S.A.
ROHS COMPLIANT 5 YEAR WARRANTY

ORDERING INFO CMR 9 [DIMMING/PHOTOCELL] [VOLTAGE] [TEMP/HUMIDITY]

DIMMING / PHOTOCELL CHOOSE ONE ONLY VOLTAGE TEMP/HUMIDITY


Blank = None Blank = 120/277 VAC Blank = Standard
D = Occupancy Controlled Dimming 347 = 347 VAC LT = Low Temp
P = Photocell
ADC = Photocell w/ Dimming
Revised 06.16.10 © 2010 Sensor Switch

COVERAGE PATTERN
Note: Screw axis is
9 STANDARD RANGE 360º LENS aligned with a long
detection segment
• Best choice for small motion (e.g. hand movements) detection
• Viewing angle of 56º in a 360º conical shaped pattern
• Provides 12 ft (3.66 m) radial coverage when mounted to
standard 9 ft (2.74 m) ceiling
• 8 to 15 ft (2.44 to 4.57 m) mounting heights provide 10 to 20 ft
3.7 12
(3.05 to 6.10 m) radial coverage

SIDE VIEW TOP VIEW 1.8 6


0 ft 0m

0m 0 ft

9 2.7
1.8 6
3.7 1.8 0m 1.8 3.7
12 6 0 ft 6 12 3.7 12

WIRING (DO NOT WIRE HOT) H N

BLK
STANDARD WIRING SWITCH

}
BLK LOAD
BLACK* - Line Input
*BLACK wires can be reversed WHT
BLACK* - Load Output
WHITE - Neutral VIO (+) [D,ADC] Dimming Options
GRY (-)
347 VAC OPTION (347)
Black wires are replaced w/ Red wires
DIMMING OPTIONS (D, ADC) SENSORS IN PARALLEL
VIOLET - Connect to Violet control wire from 0-10 VDC ensors may be wired in parallel; however, the
S
dimmable ballast maximum load ratings stay the same. Do not wire
GRAY - Connect to Gray common wire from ballast sensors with P or ADC option in parallel.
HOT
INITIAL POWER UP
he sensor’s relay is shipped in a latched closed position so
T
the lights will come on upon initial power-up. If the lights do not BLK BLK

immediately turn on (initial installation only) the latching relay BLK BLK

opened during shipment and will close within 30 secs. WHT WHT

Note: If the sensor loses power, the internal relay will latch to on. N LOAD

INSTALLATION

• Sensor’s mounting holes align with 3.5” octagon or single gang PUSH BUTTON
handy box (screws not provided).
• Sensor will detect motions crossing segments more effectively
than motions parallel to beams.
• For optimal detection, position sensor such that segments are
crossed upon entrance and unable to view outside the space.

PROGRAMMING
Refer to instruction card IC7.001 for default settings and directions on programming the sensor via the push-button.

WARRANTY: Sensor Switch, Inc. warrants these products to be free of defects in manufacture and workmanship for
a period of 60 months. Sensor Switch, Inc., upon prompt notice of such defect, will, at its option, provide a Returned
Material Authorization number and repair or replace returned product.
LIMITATIONS AND EXCLUSIONS: This Warranty is in full lieu of all other representation and expressed and
implied warranties (including the implied warranties of merchantability and fitness for use) and under no circumstances
shall Sensor Switch, Inc. be liable for any incidental or consequential property damages or losses.
TS-CMR-007A
900 Northrop Road, Wallingford, CT 06492 • 1.800.PASSIVE • FX 203.269.9621 • www.sensorswitch.com

You might also like