0% found this document useful (0 votes)
107 views17 pages

Sensor de Movimiento Casa

The document describes a Maestro occupancy/vacancy sensor switch that combines an occupancy sensor with a Lutron switch. The sensor uses passive infrared technology to detect occupancy and can be set to turn lights on/off automatically or manually. It has adjustable settings for sensitivity, timeout, and ambient light level.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
107 views17 pages

Sensor de Movimiento Casa

The document describes a Maestro occupancy/vacancy sensor switch that combines an occupancy sensor with a Lutron switch. The sensor uses passive infrared technology to detect occupancy and can be set to turn lights on/off automatically or manually. It has adjustable settings for sensitivity, timeout, and ambient light level.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

Maestro

Switch with Occupancy/Vacancy Sensor

Sensor
369666c 1 09.11.12

Maestro Occupancy sensing switch


The Lutron Maestro Occupancy sensing switch combines a
Maestro switch with a passive infrared occupancy or vacancy
sensor. The sensor detects the heat from occupants moving
within an area to determine whether the space is occupied.
Based on the feedback from the sensor, the occupancy
sensing switch will adjust the load accordingly.
Features
Passive infrared sensors with exclusive Lutron XCTTM
Technology for fine motion detection
180 sensor field-of-view
Up to 30 ft x 30 ft (9 m x 9 m) [900 ft 2 (81 m 2)] major motion
coverage and 20 ft x 20 ft (6 m x 6 m) [400 ft 2 (36m 2)] minor
motion coverage
Occupancy version can be set to Auto-ON / Auto-OFF or
Manual-ON / Auto-OFF
Vacancy version available to meet CA Title 24 requirements
Adjustable timeout (1, 5, 15, or 30 minutes) and high/low
sensitivity adjustment
Occupancy sensing switch loads: incandescent, halogen, ELV,
MLV, CFL, LED, magnetic fluorescent, electronic fluorescent,
and fan.

MS-OPS2
MS-OPS5M
MS-OPS6M2-DV
MS-OPS6M2N-DV
MS-VPS2
MS-VPS5M
MS-VPS6M2-DV
MS-VPS6M2N-DV

UMS-OPS6M-DV
 MS-VPS6M-DV
U

Models available
MS-OPS2
MS-OPS5M
MS-OPS6M2-DV
MS-OPS6M2N-DV
UMS-OPS6M-DV
MS-VPS2
MS-VPS5M
MS-VPS6M2-DV
MS-VPS6M2N-DV
UMS-VPS6M-DV

Job Name:
Job Number:

S p e c i f i c at i o n S u b m i t ta l
Model Numbers:

Page

Maestro

Switch with Occupancy/Vacancy Sensor

Sensor
369666c 2 09.11.12

Specifications
Regulatory Approvals
UL Listed to U.S. and Canadian safety
requirements.
NOM Certification (MS- models only).
Power
120 V~ 50/60 Hz1
120277 V~ 50/60 Hz1





Key Design Features


All lighting loads.
Crush/tamper resistant lens.
Smart ambient light detection.
Adaptive switching algorithm for extended relay life.
XCTTM Technology for fine motion detection.
Lutron patented Softswitch.

Environment
A
 mbient operating temperature: 32 F to 104 F
(0 C to 40 C), 0%90% humidity, non-condensing.
Indoor use only.

Advanced Features
Switching
Standard zero crossmaximizes relay life by
switching at the point of minimum energy on the AC
power curve.
Adaptive zero crossmaximizes relay life by
switching at the point of minimum energy on the AC
power curve. Actively adapts to variations in relay
timing.
Lutron Patented Softswitch circuiteliminates
arcing at mechanical contacts when loads are
switched. Extends relay life to an average of
1,000,000 cycles (on/off) for resistive, capacitive, or
inductive sources.
XCTTM Technology
Advanced sensing technology for fine motion
detection ensures that the lights stay on while the
room is occupied, and that the sensor does not
turn on falsely when there is no occupancy in the
room. For more information, see www.lutron.com/
TechnicalDocumentLibrary/white%20paper%20
XCT%204-23-09%20B.pdf

Warranty
5-Year Limited Warranty. For additional Warranty
information, please visit www.lutron.com/
TechnicalDocumentLibrary/Sensor_Warranty.pdf

Additional Information
When using MS-OPS2, MS-OPS5M,
MS-OPS6M2-DV, MS-VPS2, MS-VPS5M, or
MS-VPS6M2-DV on GFI-controlled circuits, please
see Lutron P/N 048440.
For Maestro Occupancy sensing dimmer models,
please see Lutron P/N 369270.
For use with MA-AS, MSC-AS, MA-AS-277, or
MSC-AS-277 to control the load from more than two
locations, please see Lutron P/N 048435.
For more information, please see www.lutron.com/
occvacsensors
Lutron Technical Hotline: 1.800.523.9466.

Maximum current ratings for individual models are provided in the Selection Matrix on page 4.

Job Name:
Job Number:

S p e c i f i c at i o n S u b m i t ta l
Model Numbers:

Page

Maestro

Switch with Occupancy/Vacancy Sensor

Sensor
369666c 3 09.11.12

Custom Settings
Ambient Light Detection
Lights turn on only if natural light in room is low.
SmartAmbient light threshold adjusts precisely to
the users preference.
Instructions: If switch turns on when there is enough natural light, or if
switch does not turn on when there is not enough natural light, press
the large button within 5 seconds of entering the room. Over time, this
interaction will teach the switch your preferred setting.

Presetshigh, medium, low, and disabled.


Sensor Operation
Occupancy/Vacancy: Auto-ON / Auto-OFF or
Manual-ON / Auto-OFF
Vacancy only: Manual-ON / Auto-OFF only
Timeout Options
(See Additional Features on page 5 for default settings)

1 Minute
5 Minutes
15 Minutes
30 Minutes

Sensitivity Options
High sensitivity (default)
Low sensitivity

Manual Off-While-Occupied Options


(MS-OPS and UMS-OPS onlysee Additional Features on page 5 for
default setting)

Enabled
When the Occupancy sensing switch is manually
turned off, the Occupancy sensing switch will not
turn the lights back on automatically while the
room is occupied.
Once the room is vacated, the Auto-ON feature
returns to normal operation after the timeout
period has expired.
This may be the preference in conference rooms
or classrooms while viewing presentations. This
feature requires motion to keep the lights off.
Disabled
When the Occupancy sensing switch is manually
turned off, the Auto-ON feature will return to
normal operation after 25 seconds.
This may be the preference if the user always
wants the lights to turn on upon entering and the
lights to turn off when the room is vacant.

Auto-ON Options
(MS-OPS and UMS-OPS only)

Occupancy (default): Auto-ON / Auto-OFF


Vacancy*: Manual-ON / Auto-OFF
Low Light: Lights turn on only if needed (if ambient
light is below threshold)
* There is a 15-second grace period that begins when the lights are
automatically turned off, during which the lights will automatically turn
back on in response to motion. This grace period is provided as a safety
and convenience feature in the event that the lights turn off while the
room is still occupied, so that the user does not need to manually turn
the lights back on. After 15 seconds, the grace period expires and the
lights must be manually turned on.

Job Name:
Job Number:

S p e c i f i c at i o n S u b m i t ta l
Model Numbers:

Page

Maestro

Switch with Occupancy/Vacancy Sensor

Sensor
369666c 4 09.11.12

Selection Matrix
Vacancy only2 (Title 24 compliant)
Single-pole only
Single-pole / 3-way
capability

Works with standard mechanical 3-way switch3


Works with companion switch3, 4
All lighting loads (120 V~ only)
All lighting loads (120277 V~ only)

Max current rating

Fan (120 V~)


Light + Fan (120 V~)
Neutral wire required

Ground wire required for functionality Off-state power


Minimum load required
Relevant wiring diagram
Model

Number1

MS-OPS2-XX
MS-OPS5M-XX
MS-OPS6M2-DV-XX
MS-OPS6M2N-DV-XX
UMS-OPS6M-DV-XX5
MS-VPS2-XX
MS-VPS5M-XX
MS-VPS6M2-DV-XX
MS-VPS6M2N-DV-XX
UMS-VPS6M-DV-XX5

2A

5A

2A

3A 3A
6A 3A 3A
6A 3A 3A

26
711
25 W

3A 3A
6A 3A 3A
6A 3A 3A

2, 3, 5

6A 3A 3A
5A

1
2, 3, 5
26

6A 3A 3A

1217

711
25 W

1217

XX in model number represents color/finish code.

 ccupancy sensors can be configured as Auto-ON / Auto-OFF or Manual-ON / Auto-OFF.


O
Vacancy sensors are configured as Manual-ON / Auto-OFF only.

Standard mechanical 3-way switch cannot be combined with companion switch.

Companion switch MA-AS, MSC-AS, MA-AS-277, or MSC-AS-277 is required for multi-location installations (more than two locations controlling the
same lighting circuit). Up to nine companion switches may be connected.

BAA-compliant models.

Job Name:
Job Number:

S p e c i f i c at i o n S u b m i t ta l
Model Numbers:

Page

Maestro

Switch with Occupancy/Vacancy Sensor

Sensor
369666c 5 09.11.12

Additional Features
Crush/tamper-resistant lens
Ambient light detection
Switching
XCTTM technology
Manual off-while-occupied default setting
Default timeout (minutes)
Model

Number1

MS-OPS2-XX

Smart

Standard

MS-OPS5M-XX

Smart

Standard

Smart

Adaptive

Smart

Adaptive

Presets

Softswitch

MS-VPS2-XX

Smart

Standard

MS-VPS5M-XX

Smart

Standard

Smart

Adaptive

Smart

Adaptive

Presets

Softswitch

MS-OPS6M2-DV-XX
MS-OPS6M2N-DV-XX

UMS-OPS6M-DV-XX

MS-VPS6M2-DV-XX
MS-VPS6M2N-DV-XX
UMS-VPS6M-DV-XX
1

Disabled

Disabled

Enabled

15

Enabled

15

Enabled

5
5
5
15
15
5

XX in model number represents color/finish code.

Job Name:
Job Number:

S p e c i f i c at i o n S u b m i t ta l
Model Numbers:

Page

Maestro

Switch with Occupancy/Vacancy Sensor

Sensor
369666c 6 09.11.12

Occupancy Sensing Switch Placement and Operation


T
 he ability of the Occupancy sensing switch to detect motion requires line-of-sight of room occupants. The
Occupancy sensing switch must have an unobstructed view of the room.
Hot objects and moving air currents can affect the performance of the Occupancy sensing switch.
The performance of the Occupancy sensing switch depends on a temperature differential between the ambient
room temperature and that of room occupants. Warmer rooms may reduce the ability of the Occupancy sensing
switch to detect occupants.
Definitions
Major motion: movement of a person entering or passing through an area.
Minor motion: movement of a person occupying an area and engaging in small activities (e.g., reaching for a
telephone, turning the pages of a book, opening a file folder, picking up a coffee cup).
NEMA WD7 Coverage

Horizontal Beam Diagram


30 ft
(9 m)

Major motion coverage: 900 ft2 (81 m2)

25 ft
(7.5 m)

Minor motion coverage: 400 ft2 (36 m2)

20 ft
(6 m)

15 ft
(4.5 m)

15 ft
(4.5 m)
10 ft
(3 m)
5 ft
(1.5 m)

10 ft
(3 m)

0
5 ft
(1.5 m)

5 ft
(1.5 m)

10 ft
(3 m)
15 ft
(4.5 m)
20 ft
(6 m)

25 ft
(7.5 m)
30 ft
(9 m)

5 ft
(1.5 m)

10 ft
(3 m)

Vertical Beam Diagram


4 ft
(1.2 m)

15 ft
(4.5 m)
0

5 ft
(1.5 m)

Job Name:
Job Number:

10 ft
(3 m)

15 ft
(4.5 m)

20 ft
(6 m)

S p e c i f i c at i o n S u b m i t ta l
Model Numbers:

25 ft
(7.5 m)

30 ft
(9 m)

5 ft
(1.5 m)

10 ft
(3 m)

15 ft
(4.5 m)

20 ft
25 ft 30 ft
(6 m) (7.5 m) (9 m)

Page

Maestro

Switch with Occupancy/Vacancy Sensor

Sensor
369666c 7 09.11.12

Dimensions
Measurements shown as: in (mm).
Front View

Side View

41116
(119)

21516
(75)

118
(30)
5/16 (8)
1/8 (3)

Ganging
When ganging with other controls in the same wallbox, remove inside fins (UMS-OPS6M-DV and
UMS-VPS6M-DV only).
Each control has
inside fins removed

Middle of Gang control has


all fins removed

Do NOT remove outside fins on End of Gang controls

Job Name:
Job Number:

S p e c i f i c at i o n S u b m i t ta l
Model Numbers:

Page

Maestro

Switch with Occupancy/Vacancy Sensor

Sensor
369666c 8 09.11.12

Mounting
Mounting screws

Wallbox

Occupancy Sensing Switch

Adapter mounting screws

Wallplate Adapter / Wallplate


(sold separately)

Operation
Status LED
Indicates load status; glows softly
as night light when light is off

Tapswitch
Tap on/off

Tapswitch
Tap on/off

Sensor Lens

MS-OPS2
MS-OPS5M
MS-OPS6M2-DV
MS-OPS6M2N-DV
MS-VPS2
MS-VPS5M
MS-VPS6M2-DV
MS-VPS6M2N-DV

Sensor LED (behind lens)


Pulses during configuration
of custom settings and in the
Test mode.

Sensor Lens

Sensor LED
Pulses to
acknowledge
motion when
the load is ON.

FASSTM
Front
Accessible
Service
Switch

UMS-OPS6M-DV
 MS-VPS6M-DV
U

Important notice
FASSTMFront Accessible Service Switch
To service load, remove power by pulling the
FASSTM switch out completely on either the Dimmer
or Companion Dimmer. After servicing load, push
the FASSTM switch back in fully to restore power to
the control.

Job Name:
Job Number:

S p e c i f i c at i o n S u b m i t ta l
Model Numbers:

Page

Maestro

Switch with Occupancy/Vacancy Sensor

Sensor
369666c 9 09.11.12

Wiring Diagrams
Wiring Diagram 1

Wiring Diagram 2

Single Location Installation (120 V~)


-OPS2 and -VPS2

Single Location Installation (120 V~)1


-OPS5M, -OPS6M2-DV, -VPS5M, -VPS6M2-DV
Occupancy
sensing switch

Occupancy
sensing switch

Blue1

Black

Black

Black

Hot/Live

Hot/Live

Green

Bare
120 V~
50/60 Hz

Bare

Load

Ground

120 V~
50/60 Hz

Black
Green
Ground

Load

Neutral

Neutral

Wiring Diagram 3
3-way Installation with Standard Mechanical Switch (120 V~)2, 3
-OPS5M, -OPS6M2-DV, -VPS5M, -VPS6M2-DV
Standard
mechanical switch

Different
color screw
(Common)

Hot/Live

Occupancy sensing
switch
Black

Black

Blue

Green

Bare

Jumper wire

Green
screw

120 V~
50/60 Hz

Ground

Load

Ground
Neutral

OR
Occupancy
sensing switch

Standard
mechanical switch

Black

Hot/Live

Black

Bare
120 V~
50/60 Hz

Different
color screw
(Common)

Blue
Green

Jumper wire
Ground

Green
screw

Load
Ground

Neutral
1
2
3

When using controls in single location installations, tighten the blue terminal or cap blue wire. Do not connect the blue terminal/wire to any other wire or to ground.
Only one Occupancy sensing switch can be used per multi-location circuit.
A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most Occupancy sensing switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).

Continued on next page...

Job Name:
Job Number:

S p e c i f i c at i o n S u b m i t ta l
Model Numbers:

Page

Maestro

Switch with Occupancy/Vacancy Sensor

Sensor
369666c 10 09.11.12

Wiring Diagrams

(continued)

Wiring Diagram 4
3-way Installation with Standard Mechanical Switch (277 V~)1, 2, 3
-OPS6M2-DV, -VPS6M2-DV
Standard
mechanical switch

Different
color screw
(Common)

Hot/Live

Occupancy sensing
switch
Black

Black

Blue

Green

Bare

Jumper wire

Green
screw

277 V~
50/60 Hz

Load

Ground
Ground

Neutral

OR
Occupancy
sensing switch

Standard
mechanical switch

Black

Hot/Live

Black

Different
color screw
(Common)

Blue

Jumper
wire

Green

Bare
277 V~
50/60 Hz

Ground

Green
screw

Load
Ground

Neutral

Wiring Diagram 5
Multi-Location Installation (120 V~)1, 2, 4
-OPS5M, -OPS6M2-DV, -VPS5M, -VPS6M2-DV with MA-AS or MSC-AS
MA-AS or
MSC-AS

MA-AS or
MSC-AS

Blue

Hot/Live

Black

Brass
Green

120 V~
50/60 Hz

Occupancy sensing
switch4

Black

Brass

Black

Bare

Green
Ground

Blue

Blue

Ground

Black
Green
Ground

Load

Neutral
1
2
3
4

A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most Occupancy sensing switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
Only one Occupancy sensing switch can be used per multi-location circuit.
Fan load applies to 120 V~ only (not for 277 V~).
Occupancy sensing switch can be installed in any location.

Continued on next page...

Job Name:
Job Number:

S p e c i f i c at i o n S u b m i t ta l
Model Numbers:

Page

10

Maestro

Switch with Occupancy/Vacancy Sensor

Sensor
369666c 11 09.11.12

Wiring Diagrams

(continued)

Wiring Diagram 6
Multi-Location Installation (277 V~)1, 2, 3, 4
-OPS6M2-DV, -VPS6M2-DV with MA-AS-277 or MSC-AS-277
MA-AS-277 or
MSC-AS-277

MA-AS-277 or
MSC-AS-277

Blue

Hot/Live

Black

277 V~
50/60 Hz

Red

Green

Blue

Blue

Black

Red

Green
Ground

Occupancy sensing
switch3

Black

Bare
Ground

Black
Green
Ground

Load

Neutral

 single standard mechanical 3-way switch or up to 9 companion switches may be connected to most Occupancy sensing switches.
A
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
2 Only one Occupancy sensing switch can be used per multi-location circuit.
3 Occupancy sensing switch can be installed in any location.
4 Fan load applies to 120 V~ only (not for 277 V~).

Continued on next page...

Job Name:
Job Number:

S p e c i f i c at i o n S u b m i t ta l
Model Numbers:

Page

11

Maestro

Switch with Occupancy/Vacancy Sensor

Sensor
369666c 12 09.11.12

Wiring Diagrams

(continued)

Wiring Diagram 7
Single Location Installation (120-277 V~)1, 2
-OPS6M2N-DV, -VPS6M2N-DV
Occupancy
sensing switch
Blue1

Black

Black

Hot/Live
Bare
120-277 V~
50/60 Hz

White

Load

Ground

Neutral

Wiring Diagram 8
3-way Installation with Standard Mechanical Switch (120 V~)3, 4
-OPS6M2N-DV, -VPS6M2N-DV
Standard
mechanical switch

Occupancy sensing
switch
Black

Different
color screw
(Common)

Hot/Live

120 V~
50/60 Hz

Black

Blue
Bare

Jumper wire

Ground

Green
screw

White

Load

Ground
Neutral

OR
Occupancy
sensing switch

Standard
mechanical switch

Black

Hot/Live

Black

Different
color screw
(Common)

Blue

Bare
120 V~
50/60 Hz

Ground

Jumper wire
White

Green
screw

Load
Ground

Neutral
1
2
3
4

 hen using controls in single location installations, tighten the blue terminal or cap blue wire. Do NOT connect the blue terminal/wire to any other wire or to ground.
W
Fan load applies to 120 V~ only (not for 277 V~).
Only one Occupancy sensing switch can be used per multi-location circuit.
A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most Occupancy sensing switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).

Continued on next page...

Job Name:
Job Number:

S p e c i f i c at i o n S u b m i t ta l
Model Numbers:

Page

12

Maestro

Switch with Occupancy/Vacancy Sensor

Sensor
369666c 13 09.11.12

Wiring Diagrams

(continued)

Wiring Diagram 9
3-way Installation with Standard Mechanical Switch (277 V~)1, 2, 3
-OPS6M2N-DV, -VPS6M2N-DV
Standard
mechanical switch

Different
color screw
(Common)

Hot/Live

277 V~
50/60 Hz

Occupancy sensing
switch
Black

Black

Blue
Bare

Jumper wire
Green
screw

Ground

Load

White

Ground
Neutral

OR
Occupancy
sensing switch

Standard
mechanical switch

Black

Hot/Live

Black
Bare

277 V~
50/60 Hz

Ground

Different
color screw
(Common)

Blue
White

Jumper wire
Green
screw

Load
Ground

Neutral

1
2
3

Only one Occupancy sensing switch can be used per multi-location circuit.
A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most Occupancy sensing switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
Fan load applies to 120 V~ only (not for 277 V~). 

Continued on next page...

Job Name:
Job Number:

S p e c i f i c at i o n S u b m i t ta l
Model Numbers:

Page

13

Maestro

Switch with Occupancy/Vacancy Sensor

Sensor
369666c 14 09.11.12

Wiring Diagrams

(continued)

Wiring Diagram 10
Multi-Location Installation (120 V~)1, 2, 3
-OPS6M2N-DV, -VPS6M2N-DV with MA-AS or MSC-AS
MA-AS or
MSC-AS

Occupancy sensing
switch3

MA-AS or
MSC-AS

Blue

Hot/Live

Brass

Black

Black

Green

120 V~
50/60 Hz

Blue

Blue

Brass

Black

Black

Bare

Green

Ground

White

Load

Ground

Ground

Neutral

Wiring Diagram 11
Multi-Location Installation (277 V~)1, 2, 3, 4
-OPS6M2N-DV, -VPS6M2N-DV with MA-AS-277 or MSC-AS-277
MA-AS-277 or
MSC-AS-277

MA-AS-277 or
MSC-AS-277

Blue

Blue

Hot/Live

Red

Black

Green

277 V~
50/60 Hz

Black

Red

Blue

Black

Black

Bare

Green
Ground

Occupancy sensing
switch3

Ground

Ground

White

Load

Neutral

1
2
3
4

A single standard mechanical 3-way switch or up to 9 companion switches may be connected to most Occupancy sensing switches.
Standard mechanical 3-way switch cannot be combined with companion switch. Total blue terminal wire length may be up to 150ft (46m).
Only one Occupancy sensing switch can be used per multi-location circuit.
Occupancy sensing switch can be installed in any location.
Fan load applies to 120 V~ only (not for 277 V~).

Continued on next page...

Job Name:
Job Number:

S p e c i f i c at i o n S u b m i t ta l
Model Numbers:

Page

14

Maestro

Switch with Occupancy/Vacancy Sensor

Sensor
369666c 15 09.11.12

Wiring Diagrams

(continued)

Wiring Diagram 12

Wiring Diagram 13

Single Location Installation1, 2


-OPS6M-DV and -VPS6M-DV

Single Location Installation with Shunt Capacitor1, 2, 3


-OPS6M-DV and -VPS6M-DV

Occupancy
sensing switch

Occupancy
sensing switch

Blue1

Black

Blue1

120-277 V~
50/60 Hz

Red

Black

Red

Hot/Live

Optional

Hot/Live
Green

Green

120-277 V~
50/60 Hz

Load
Ground

Load

Shunt
Capacitor2

Ground

Neutral

Neutral

Wiring Diagram 14
Multi-Location Installation (120 V~)1, 4, 5, 6
-OPS6M-DV and -VPS6M-DV with MA-AS or MSC-AS
MA-AS or
MSC-AS

MA-AS or
MSC-AS

Occupancy sensing
switch6

Blue

Hot/Live

Black

Brass

Brass

Black

Green

120 V~ 50/60 Hz

Blue

Blue

Black

Red
Green

Green

Load
Ground

Ground

Ground

Neutral

Wiring Diagram 15
Multi-Location Installation (277 V~)1, 2, 3, 4, 5, 6
-OPS6M-DV and -VPS6M-DV with MA-AS-277 or MSC-AS-277
MA-AS-277 or
MSC-AS-277

MA-AS-277 or
MSC-AS-277

Blue

Hot/Live

Black

Red
Green

277 V~ 50/60 Hz

Blue

Blue

Red

Black

Red

Black
Green

Green
Ground

Occupancy sensing
switch6

Ground

Load
Ground

Neutral
1
2
3
4
5
6

When using controls in single location installations, tighten the blue terminal or cap blue wire. Do not connect the blue terminal/wire to any other wire or to ground.
Fan load applies to 120 V~ only (not for 277 V~).
Optional shunt capacitor must be installed inside the load fixture or in a separate J-box.
Up to 9 companion switches may be connected to an Occupancy sensing switch. Total blue terminal wire length may be up to 250ft (76m).
Only one Occupancy sensing switch can be used per multi-location circuit.
Continued on next page...
Occupancy sensing switch can be installed in any location.

Job Name:
Job Number:

S p e c i f i c at i o n S u b m i t ta l
Model Numbers:

Page

15

Maestro

Switch with Occupancy/Vacancy Sensor

Sensor
369666c 16 09.11.12

Wiring Diagrams

(continued)

Wiring Diagram 16
Multi-Location Installation with Shunt Capacitor (120 V~)1, 2, 3, 4
-OPS6M-DV and -VPS6M-DV with MA-AS or MSC-AS
MA-AS or
MSC-AS

MA-AS or
MSC-AS

Occupancy sensing
switch4

Blue

Hot/Live

Brass

Black

Blue

Blue

Brass

Black

Black

Red
Optional

Green

120 V~ 50/60 Hz

Green

Green

Load
Ground

Shunt
Capacitor1

Ground

Ground

Neutral

Wiring Diagram 17
Multi-Location Installation with Shunt Capacitor (277 V~)1, 2, 3, 4, 5
-OPS6M-DV and -VPS6M-DV with MA-AS-277 or MSC-AS-277
MA-AS-277 or
MSC-AS-277

MA-AS-277 or
MSC-AS-277

Blue

Blue

Hot/Live

Red

Black

Occupancy
sensing switch4

Red

Black

Blue

Red

Black

Optional
Green

277 V~ 50/60 Hz

Green

Green
Load

Ground

Ground

Shunt
Capacitor1

Ground

Neutral

1
2
3
4
5

 ptional shunt capacitor must be installed inside the load fixture or in a separate J-box.
O
Up to 9 companion switches may be connected to an Occupancy sensing switch. Total blue terminal wire length may be up to 250ft (76m)
Only one Occupancy sensing switch can be used per multi-location circuit.
Occupancy sensing switch can be installed in any location.
Fan load applies to 120 V~ only (not for 277 V~).

Job Name:
Job Number:

S p e c i f i c at i o n S u b m i t ta l
Model Numbers:

Page

16

Maestro

Switch with Occupancy/Vacancy Sensor

Sensor
369666c 17 09.11.12

Colors and Finishes


Gloss Finishes

Satin Finishes

White
WH

Ivory
IV

Hot
HT

Merlot
MR

Plum
PL

Turquoise
TQ

Almond
AL

Light Almond
LA

Taupe
TP

Eggshell
ES

Biscuit
BI

Snow
SW

Gray
GR

Brown
BR

Palladium
PD

Midnight
MN

Sienna
SI

Terracotta
TC

Greenbriar
GB

Bluestone
BG

Mocha Stone
MS

Goldstone
GS

Desert Stone
DS

Stone
ST

Limestone
LS

Sea Glass
SG

Black
BL

Due to printing limitations, colors and finishes shown cannot be guaranteed to match actual product colors perfectly.
Color chip keychains are available for more precise color matching:
Gloss Finishes: DG-CK-1
Satin Finishes: SC-CK-1

Job Name:
Job Number:

S p e c i f i c at i o n S u b m i t ta l
Model Numbers:

Page

17

You might also like