SAUDI OGER LTD.
(Project Name)
INSPECTION & TEST PLAN                                                             PLASTERING                                                                                      ITP-C-32 Rev. 00
Project No.:                                                                                       Project Title:
Contractor:                                                                                        Contract No:                                                                          CIVIL
Item No.
                                                                                                                                                                    Contractor Contractor
                                                                                       Applicable Code or                                        Test Record or                           (Client) Engr /
           Activity                  Inspection and Test Point                                                      Acceptance Criteria                               Site      QA/QC
                                                                                            Standard                                               Document                                 Inspector
                                                                                                                                                                    Engineer Engrineer
 1.0 MATERIAL         1.1 Aggregate: Natural sand of the required gradation.       Project specification            As per spec.               Laboratory records
                                                                                                                                               Visual                   R           R            R
                      1.2 Cement: Portland cement type I.                          Project specification            As per spec.               Mill certificate
                                                                                                                                                                       I/R         I/R           I/R
 2.0 EXECUTION        2.1 Check surface preparation, masonry, concrete.            Project specification            As per spec. and Code      Visual
                                                                                                                                               QR-C-32                  I           W            W
                      2.2 Check embeded items within wall have been already Project specification                   As per specification and   QR-C-32
                          installed.                                                                                approved drawings.                                  I           W            S
                      2.3 Electro-Mechanical services have been tested and         Project specification            As per specification and   Electromechanical
                          approved.                                                                                 approved drawings.         RFI's, QR-C-32           I           W            S
                      2.4 Check required plaster mix for exterior wall, interior   Project specification            As per spec.               QR-C-32
                          wall and ceiling.                                                                         ASTM C-926                                          I           W            S
                      2.5 Application of dash coat, scratch coat, brown coat    Project specification               As per spec.               QR-C-32
                          and finish coat as per mix design and required                                            ASTM C-926                                          I           S            S
                          thickness.
                      2.6 Finish coat shall be cured for a minimum of 48 hours. Project specification               As per spec.               QR-C-32
                                                                                                                                                                        I           S            S
                      2.7 Plaster shall extend 100mm beyond finished ceiling       Project specification            As per spec.               QR-C-32
                          level for rooms with suspended ceiling.                                                                                                       I           S            S
                      2.8 Check plaster variation to true finish.                  Project specification            Maximum variation is 3mm QR-C-32
                                                                                                                    in 3m.                                              I           S            S
                                                 I=Inspect or Perform Work; W=Witness Point; R=Review/ approve Records or Documentation; S=Surveilance or Monitor; H=Hold Point                        Page 1 of 1