CHECK LIST FOR AIR FIN COOLER (AIR EXCHANGER)
UNIT: 120 AFC NO: 120 –E – 12B SERVICE: SEPARATOR CONDENSER
TUBE BUNDLE NO: ___________________IN USE FROM: __________________________
TUBE MATERIAL: SA 213 T11 TUBE NOS/SIZE: 240/25mmOD X 2.5mmTHIK.
LAST INSPECTED ON: ________________________
REASON FOR OUTAGE: X SHUTDOWN PRE – SHUTDOWN REPORTED LEAKING OTHERS
JOBS AS PER PREVIOUS ACTION REPORT/WORK LIST/NOTE [Give reference/Date]:_________
STRESS RELEIVED: YES NO
ENVIRONMENT: H2S CAUSTIC ACIDIC HYDROGEN OTHERS
EQUIPMENT IDLING: YES NO
NDT REQUIRED: D.P. TEST 1W.F.M.P.I X U.T. SCANNING X ET / RFET
HYDROTEST:
TUBE TEST
PRESSURE (Kg/cm2g) 69KG/CM2
TEST DATE 31/12/13
NO OF TUBES PLUGGED PREVIOUS PRESENT TOTAL % OF TUBES PLUGGED
(GIVE PASS WISE):
PARTIAL RETUBING DETAILS IF ANY:
PREVIOUS PRESENT Attach tube sheet layout showing
NO OF TUBES (GIVE PASS WISE) partially renewed tubes (date wise).
DATE
RETUBING OF THE BUNDLE REQUIRED IN THE NEXT OUTAGE: PARTIAL COMPLETE NII
ACTION REPORT ISSUED: NO. __________________.DATED: __________________
NEXT INSPECTION ON : __________________
OBSERVATIONS
1. HEADER BOX (FRONT) :
INTERNAL (After removal of plug, No of plugs removed 75 out of 240) :
Checked for Corrosion / Erosion / Pitting (If localized, specify location)
FOUND SATISFACTORY
Condition of plug threads (internal)
FOUND SATISFACTORY
Condition of tube & Tube sheet (viewed from opened plugs)
FOUND IN GOOD CONDITION
EXTERNAL :
Checked for corrosion and paint / coating condition:
MINOR PAINTING DAMAGE WAS NOTICED
Condition of plugs (Not Removed) _________
Condition of Inlet & Outlet and any other nozzles (including serrations):
FOUND SATISFACTORY
2. HEADER BOX (REAR) :
INTERNAL (After removal of plug, No of plugs removed ____ out of _____) :
Checked for Corrosion / Erosion / Pitting (If localized, specify location)
MINOR DEPOSIT WAS NOTICED
Condition of plug threads (internal)
FOUND SATISFACTORY
EXTERNAL :
Checked for corrosion and paint / coating condition:
MINOR PAINTING DAMAGE WAS NOTICED
Condition of tube (viewed from opened plugs)
FOUND SATISFACTORY
Condition of plugs (Not Removed) ____________
Condition of Inlet & Outlet and any other nozzles (including serrations):
FOUND IN GOOD CONDITION
3. THICKNESS MEASUREMENT OF HEADER ASSEMBLY:
HEADER ASSEMBLY THICKNESS
NOMINAL MESURED MIN MESURED MAX
FRONT 25(T&B), 28(S) 25.3 (T&B), 30.6(S) 25.7(T&B),30.9(S)
REAR 25(T&B),28(S) 25.2(T&B), 30.7(S) 25.8(T&B),30.9(S)
* T&B—Top & bottom, * S—Sides
4. TUBE SECTION :
Check for Fins condition
MINOR DAMAGE WAS NOTICED
Check for Tubes condition
FOUND IN GOOD CONDITION
5. THICKNESS MEASUREMENT OF TUBES ASSEMBLY:
Tubes Assembly THICKNESS
NOMINAL MESURED MIN MESURED MAX
FRONT
REAR
6. Condition of Fan Assembly :
FOUND SATISFACTORY
7. Condition of Structures / Foundation Bolt / Supports / Earthing Lug :
FOUND IN GOOD CONDITION
From GOPEC From BPCL
Name & Sign: Name & Sign: