IN-LINE MIXED FLOW DUCT EXPLOSION PROOF FANS
TD-ATEX Series
Low profile in-line mixed flow duct
explosion proof fans. TD-800 Ex is
manufactured in antistatic plastic
material. The others models are
manufactured from sheet steel protected
with black polyester paint coating.
Detachable fan unit without demounting
duct connections.
ATEX
Explosion proof versions in accordance
with ATEX Directive, for single phase
230V-50Hz. Motors IP44, Class B.
For ambient working temperatures
from -20ºC to +40ºC.
- ATEX Increased safety - Gas
For model 800.
II 2G Ex e IIC T3 Gb
EC: LOM 08 ATEX 2052 X Supplement 2.
For models 1100 and 1200.
II 2G Ex e IIC T3 Gb
EC: LOM 11 ATEX 2021 X Supplement 1.
See data for selection, or refer to Easyvent.
Specific applications
Mixed flow impeller External terminal box Earth connection.
Efficient performance and ATEX capacitor, External
mixed flow impeller. terminal box, IP55, easy
access, fireproof plastic V0.
758 In-Line duct fans TD-ATEX www.solerpalau.com
IN-LINE MIXED FLOW DUCT EXPLOSION PROOF FANS
TD-ATEX Series
TECHNICAL CHARACTERISTICS
Model Speed Maximum Maximum Airflow Operating Sound pressure level* Ø Weight Wiring
(rpm) absorbed absorbed at free temperature (dB(A)) Duct (kg) diagram**
power current discharge (°C) (mm) (nº)
(W) (A) (m3/h) Inlet Radiated Outlet
TD-800/200 ATEX 2450 130 0,54 1.020 -20/+40 53 43 55 200 5 38
TD-1100/250 ATEX 2630 197 0,81 1.130 -20/+40 59 46 65 250 20 38
TD-1200/315 ATEX 2600 170 0,71 1.320 -20/+40 56 44 59 315 25 38
* Radiated sound pressure level measured at 3 m in free field conditions with rigid ducts at the inlet and at the outlet, at point “B” of the curve.
** See section of Wiring Diagrams.
DIMENSIONS (mm)
I
C
B
ØD
G
E
H F
140
60
A
Model A B C ØD E F G H I
TD-800/200 ATEX 302 255 232,5 198 140 100 94 124 228,4
TD-1100/250 ATEX 386 324 291 248 168 145 140 155 339
TD-1200/315 ATEX 450 392 356 312 210 182 178 188 371
www.solerpalau.com In-Line duct fans TD-ATEX 759
IN-LINE MIXED FLOW DUCT EXPLOSION PROOF FANS
TD-ATEX Series
PERFORMANCE CURVES
– qv: Airflow in m3/h and m3/s.
– psf: Static pressure in mmWG and Pa.
– Dry air at 20ºC and 760 mmHg.
– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
psf psf psf psf
(Pa) (mmWG) (Pa) (mmWG)
300 TD-800/200 EX TD-1100/250 EX
TD-1100/250 EXE
30 500
50
250
25 400
40
200 20
Pabs 300 Pabs
30
W W
psf
150 p
15 sf
C
150
(Pa) (mmWG) 300
TD-1100/250 EXE
500 C
50 120 200 20 250
100 10
90 200
B
400 B 150
405 60 100 10
50 100
30
A 50
3000 0 A
300 Pabs 0 0 0
0 200 400 600 800 1000 qv [mW3/h] 0 200 400 600 800 1000 qv [m3/h]
300
0.00 0.05 0.10 0.15 0.20
C 0.25 0.30 qv [m3/s] 0.00 0.05 0.10 0.15 0.20 0.25 0.30 qv [m3/s]
200 20 250
TD-800/200 EX 63 125 250 500 1000 2000 4000 8000 LwA TD-1100/250 EX 63 125 250 500 1000 2000 4000 8000 LwA
A 27 43 53 61 69 69 65 56 200
73 A 40 57 69 75 73 76 66 59 80
Inlet B 29 43 55 62 69 70 66 56 74
150 Inlet B 40 58 70 75 72 74 65 57 79
B
100 10 C 39 49 69 71 74 70 63 55 78 psf psf C 40 62 74 73 69 71 62 54 78
A 50 50 53 64 69 71 66 56 100
74 (Pa) (mmWG) A 54 55TD-1200/315
70 80 EXE82 81 72 62 86
Outlet B 44 45 54 66 70 71 67 57 75 700
Outlet B 48 53 70 80 81 79 70 61 85
50 70
C 39 48 68 72 75 71 64 A
55 78 C 41 56 72 80 78 76 68 58 84
0 0 A 7 38 37 44 58 61 52 39 0 63 A 32 37 45 53 63 65 55 49 68
0 200 400 600 800 1000 q v [m /h]
3 600
Radiated B 9 38 39 45 58 62 53 39 64 60
Radiated B 32 38 46 53 62 63 54 47 66
0.00 C0.05 19 0.1044 53
0.15 54 0.2063 62
0.25 qv [m366
500.30 38 /s] C 32 42 50 51 59 60 51 44 63
500
50
400 Pabs
40 W
psf psf
(Pa) (mmWG) TD-1200/315 EX
TD-1200/315 EXE 300
700 300 30
70 250
C 200
600 200 20
60 150
B 100
500 100 10
50
50
Pabs A
400 0 0 0
40 W 0 200 400 600 800 1000 1200 qv [m3/h]
300
300 30 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 qv [m3/s]
250
C 200
200 20
150
B 100
100 10
50
A
0 0 0
0 200 400 600 800 1000 1200 qv [m3/h]
0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 qv [m3/s]
TD-1200/315 EX 63 125 250 500 1000 2000 4000 8000 LwA
A 32 55 67 69 71 69 64 59 76
Inlet B 34 58 70 70 71 69 64 59 76
C 39 63 73 72 73 70 65 58 79
A 47 55 67 72 74 72 67 62 78
Outlet B 42 57 71 73 74 72 67 61 79
C 39 60 74 75 75 74 68 60 81
A 20 37 49 55 61 60 51 48 65
Radiated B 22 40 52 56 61 60 51 48 65
C 27 45 55 58 63 61 52 47 66
760 In-Line duct fans TD-ATEX www.solerpalau.com
IN-LINE MIXED FLOW DUCT EXPLOSION PROOF FANS
TD-ATEX Series
MOUNTING ACCESSORIES
MAR
Rectangular duct adapters.
E B
F
Model Type of Nominal A
ØG
TD-ATEX dim. of
ducting C
LxH
(mm) Model A B C E F ØG
MAR - 800 800/200 315 x 200 MAR - 800 355 240 37 220 335 9
MAR - 1000 1100/250 400 x 250 MAR - 1000 440 290 42 270 420 9
MAR - 2000 1200/315 500 x 315 MAR - 2000 540 355 52 355 520 9
MRJ Model Type of TD-ATEX
Grilles mounted at the inlet or outlet of the fan, to
MRJ - 800 800/200
prevent the entry of any foreign objects that could
MRJ - 1000 1100/250
damage the fan.
MRJ - 2000 1200/315
ACOPEL EX Model fan Model connection ØA B
Proof explosion flexible TD-800/200 EX ACOPEL EX-200/160 N 200 160
connection. TD-1100/250 EX ACOPEL EX-250/160 N 250 160
A
TD-1200/315 EX ACOPEL EX-315/160 N 315 160
For more information see Mounting accessories.
www.solerpalau.com In-Line duct fans TD-ATEX 761