Liquid Level / Mini-Tek
PART NUMBERS : FEATURES : DETECTION METHOD : HOW THEY WORK : SENSOR
SPECIFICATION : INSTALLATION INFO
                       HOW TO DETERMINE YOUR PART NUMBER
                                       Position Sensor
                                       POSITION SENSOR
FEATURES        top
Features:                                    Specifications:
1. Solid State Operation: No moving parts Operating            -40°C to 125°C
                                          Temperature
2. Surface mount electronics integrated      Storage           -55°C to 150°C
   with sensor package                       Temperature
3. Electrical connector mates with a      Thermal Shock        100 Cycles, -40° to 125°
   standard Packared Electric Metri-Pack
   #12065298 and provides a weather tight
   connection when installed. Connector   Vibration            20G Constant Acceleration
   material is Valox 420.
4. Housing material is Bichromate                              20 to 2000 HZ
   dipped Brass
5. Probe coating for the Conductive          Salt Fog          96 Hours, per ASTM B117
   Models is PFA per ASTM D2902
   type III. Provides excellent chemical     Case Isolation    100 MegOhms
   resistance, electrical isolation, and
   dielectric stability.
6. Probe coating for Non-Conductive          Max Torque        15 Ft. Lbs.
   Models is a Hybrid Epoxy. Provides
   excellent chemical resistance and         Probe Seal        100 PSI
   electrical isolation.                     Pressure
DETECTION METHOD              top
HOW THEY WORK             top
Mini-Tek Coolant Switches:
The Red-E Parts Mini-Tek Coolant Switches operate on a capacitance sensing principle. The
probe portion of the unit, extending into the coolant, forms one plate of the capacitor, while
the coolant forms the other plate. With coolant present, the capacitance is greater than when
the coolant is absent. This difference in capacitance is used by the integral electronics to
provide a solid-state ON-OFF Signal.
(Fluid requirements - conductive fluids such as ethelyne glycol and water. Several extended
life coolants have beed tested. The customer should verify compatibility with the fluid
intended for use in his application.)
Mini-Tek Oil Level Switches:
The Red-E Parts Mini-Tek Oil Level Switches operate similarly in any liquid hydrocarbon.
On these versions, the probe portion of the unit, extending into the oil, forms one plate of
the capacitor, while the coil forms the other plate. The slick, non-fouling coating on the
probe and the oil itself work together to form the dielectric between the capacitor plates.
With oil present, the capacitance is greater than when the oil is absent. Again, the difference
in capacitance is used by the integral electronic to provide a solid-state ON-OFF signal. The
open spaces in the coil encourage rapid drainage.
(Fluid requirements - non-conductive fluids such as diesel fuel and engine oils with a
dielectric constant of 1.8 to 2.7. Several oils have beed tested. The customer should verify
compatibility with the fluid intended for use in his application.)
SENSOR SPECIFICATIONS                    top
                      Red-E Parts Level Switch Series Specifications
                 Coolant Model          Coolant Model         Coolant       Oil Model          Oil Model
                      905                    908               Model           824                828
                                                                913
   Red-E          086714A0001            086714A0002           86715,       86431 series      085927D0001
 Parts Part                                                    86716 &
    No.                                                      86717 series
Application     Low current signal    Low current signal   Heavy duty Heavy duty       Low current signal
               applications such as  applications such as  applications applications  applications such as
                electronic control    electronic control    for driving for driving electronic modules 7-30
              modules using 5.0 VDC modules using 7-32 VDC up to 1 Amp up to 1 Amp            VDC
                                                            loads such   loads such
                                                                  as             as
                                                             indicators,    indicators,
                                                             relays, and    relays, and
                                                              solenoids.     solenoids.
  Supply         5.0+/-.25 volts          7 to 32 volts       9.0 to 32      9.0 to 32        5.0+/-.25 volts
  Voltage                                                       volts          volts
  Supply              10mA                     10mA             10mA           10mA               10mA
  Current
 Output(s)     Two complementary       Two complementary      One open       One open       Two complementary
  (Type)      CMOS outputs; L and     CMOS outputs; L and     collector      collector     CMOS outputs; L and
               NL each capable of      NL each capable of    output with    output with     NL each capable of
               sourcing or sinking     sourcing or sinking    option of      option of      sourcing or sinking
                   10mA max.               10mA max.         sourcing or    sourcing or         10mA max.
                                                             sinking up     sinking up
                                                             to 1 Amp to to 1 Amp to
                                                                load at     load at
                                                               25ºC, .5   25ºC, 0.5
                                                                Amp at      Amp at
                                                               125ºC in    125ºC in
                                                             alarm mode alarm mode
                    Outputs:                Outputs:          Outputs:       Outputs:            Outputs:
  Output       L (liquid)     NL (no           L (liquid)    NL (no           NA            NA         L (liquid)     NL (no
  Voltage                     liquid)                        liquid)                                                  liquid)
   Levels
 Condition     0.5 V max    4.0 V max      0.5 V max        5.00 +/-      2.0 V max.    2.0 V max.     0.5 V max     5.00 +/-
    1*                                                        .25V        drop across   drop across                    .25V
                                                                            switch        switch
 Condition     4.0 V min    0.5 V max          5.00 +/-     0.5 V max     1 ma max      1 ma max       5.00 +/-     0.5 V max
    2**                                          .25V                      leakage       leakage         .25V
                                                                           current       current
 Response        2 sec. max. typical            2 sec. max. typical       2 sec.max.    2 sec.max.    2 sec. typical (limited by
    Time        (limited by viscosity)         (limited by viscosity)     or optional or optional             viscosity)
                                                                         10 +/- 2sec. 10 +/- 2sec.
                                                                             Delay.      Delay.
                                                                          (limited by (limited by
                                                                           viscosity)  viscosity)
  Fastener         1/4 - 18 NPTF                   1/4 - 18 NPTF           1/4 - 18      3/8 - 18          3/8 - 18 NPTF
    Type                                                                    NPTF          NPTF
 Electrical      4 Pin termination           4 Pin termination              4 Pin          4 Pin         4 Pin termination
  Mating       designed to mate with       designed to mate with         termination    termination    designed to mate with
 Connector        Packard Electric            Packard Electric           designed to    designed to       Packard Electric
                MetriPack connector         MetriPack connector           mate with      mate with      MetriPack connector
               assembly 12048079 or        assembly 12048079 or            Packard        Packard      assembly 12048079 or
                     12065298                    12065298                  Electric       Electric           12065298
                                                                          MetriPack   MetriPack
                                                                          connector   connector
                                                                           assembly    assembly
                                                                         12048079 or 12048079 or
                                                                          12065298    12065298
*Condition 1 represents no liquid present on the probe         **Condition 2 represents probe sensor submerged in liquid.
sensor.                                                                 For models 913 and 824, output is stated for mormal
   For models 913 and 824, output is stated for alarm                   (no alarm) mode.
mode.
   High or low level alarm can be selected.
INSTALLATION INFO                        top
Directions for Retro-Fit Installation :
1. Check to see that kit has following parts:
    1. Packard connector wiring assembly with
red,
       blue and black wire leads, part #86420-
A2.
    2. Fork terminal part #39600-A1 (Panduit
P/N
       PV18-14FB-3K).
    3. Male disconnects part #39601-A1
(Panduit P/N         DV18-250MB-3K).
2. Identify wiring configuration of your
application to
   be connected to Mini-Tek 913/824 Level
Sensor
   according to the inset drawings:inset A (4
wires),                                                    (click for larger view)
   inset B (standard headlight style connector),
or
   inset C (3 wires).
                                                     Retro-fit Kit
3. Make all connections of kit wiring harness        Order  kit separately. Retrofit Kit
86420                                           Model
   -A2 as shown to your application wiring by        MTK-2 (for 913-824 only) includes: 1
   securely fastening using software provided;       Packard connector wiring assembly
Red                                             with
   to V+, blue to signal, and black to ground.       red, blue and black wire leads, 1 fork
   Important: Do Not connect Mini-Tek                terminal and 3 male disconnects.
813/824
   Level Sensor into wiring harness 86420-A2
until all
   harness wiring has been correctly installed.
The
   black ground lead for wiring harness 86420
-A2
   may be cut and stripped to appropriate
length
   for your application. If your system does
not have
   a ground lead (inset B and C), a fork
terminal has
   been provided to connect on a 1/4" stud
   or bolt for chassis grounding.
4. Since Mini-Tek Model 913/824 does not
provide
   test function, the test lead terminal from
your
   system wiring should be removed or
insulated
   by covering exposed end.
5. If vibration is a factor in your system,
proper wiring
   harness restraints are commended to avoid
   insulation wear or loosening of connections.
6. Once all connections of kit wiring harness
have
   been made to system wiring and checked,
install
   Mini-Tek 913/824 Level Sensor noting
correct
   orientation of the integral Mini-Tek
connector
   with mating Packard connector wiring
harness
   86420-A2.
Notes:
Red-E Parts recommends the use of moistureproof electrical
seal at interface of Mini-Tek Coolant and Oil Level Switch
units to prevent potential corrosion of the electrical
connections. Corrosion could cause faulty operation of the
cooling or oil sensing unit. This retrofit kit is made
available by Red-E Parts only as a means to interface
models 913/824 which have integral Packard style
moistureproof connections as replacement for models
613/624 which interface with a standard "headlight" style
connector, 4 wires or 3 wires (all non-moistureproof). Note
that models 913/824 are not for computer or low current
applications. Red-E Parts does not assume responsibility for
damages caused by misapplication from incorrect wiring or
faulty wire connections.
HOW TO DETERMINE YOUR PART NUMBER                                top
                                          Key Model Number
          Model No.                                            Description
905, 908, 913                      Coolant Level Detector
828, 824-N                         Oil Level Detector
                               Table 3 - Time Delay/Test Function
             Code                                              Description
0000-T                              No time delay w/test function
TD10-T                              10 seconds w/test function
                                                Accessories
           Part No.                                            Description
86416-A1                            Mating Connection with 6" wire leads